首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A novel and sensitive immunoassay method has been developed in which the conventional sandwich immunoassay and the highly sensitive DNA detection method, the Invader method, are combined. The signal amplification function of the latter method has been successfully used to enhance the sensitivity of the sandwich immunoassay. The new assay method may be called the Immuno-Invader assay. The assay format involves three important steps: (1) a target antigen is captured and flagged with a biotin-conjugated detection antibody by the sandwich method, (2) streptavidin and a biotin-conjugated oligonucleotide are added to form a complex with the detection antibody, and (3) the oligonucleotide in the complex is detected using the Invader method. The method was applied to the assay of human tumor necrosis factor-α (hTNF-α). Detection limits obtained were 0.1 pg/ml hTNF-α when a luminescent europium chelate was used with a time-resolved measurement mode, and 0.8 pg/ml when fluorescein was used with a normal prompt fluorescence measurement mode. On the other hand, the detection limit of a commercially available hTNF-α enzyme-linked immunosorbent assay that uses horseradish peroxidase was 3.5 pg/ml. These results demonstrate the feasibility and potential of the new assay method for highly sensitive immunoassay.  相似文献   

2.
An immunoassay for interferon-gamma (IFN-gamma) using homogeneous time-resolved fluorescence (HTRF) has been developed. In this assay, IFN-gamma can be detected by simply adding a mixture of three reagents-biotinylated polyclonal antibody, europium cryptate (fluorescence donor, EuK)-labeled monoclonal antibody, and crosslinked allophycocyanin (fluorescence acceptor, XL665) conjugated with streptavidin-and then measuring the time-resolved fluorescence. The detection limit of IFN-gamma by the proposed method is about 625 pg/ml. We applied the method to the detection of IFN-gamma secreted from NK3.3 cells and employed it in high throughput screening for IFN-gamma production inhibitors. With this screening format, IFN-gamma can be measured by directly adding the above reagents to microplate wells where NK3.3 cells are being cultured and stimulated with interleukin-12. This "in situ" immunoassay requires only pipetting reagents, with no need to transfer the culture supernatant to another microplate or wash the plate. Therefore, this screening format makes possible full automation of cell-based immunoassay, thus reducing cost and experimental time while increasing accuracy and throughput.  相似文献   

3.
Spermidine synthase (SPDS) catalyzes transfer of the propylamine group from decarboxylated S-adenosylmethionine (dcSAM) to putrescine to yield methylthioadenosine (MTA) and spermidine. SPDS plays a regulatory role in cell proliferation and differentiation. This article describes the development of a high-throughput SPDS activity assay using homogeneous time-resolved fluorescence (HTRF) based on energy transfer from europium cryptate as a donor to crosslinked allophycocyanin (XL665) as an acceptor. First a highly specific anti-MTA monoclonal antibody, MTA-7H8, was generated, and then a competitive immunoassay for MTA determination was developed using europium cryptate-labeled MTA-7H8 and XL665-labeled MTA. In our homogeneous immunoassay, the percentage molar cross-reactivity of dcSAM with MTA-7H8 was 0.01% and the detection limit of MTA was 2.6 pmol/well. Our HTRF assay uses only one assay plate in which both enzyme reaction and MTA determination can be done successively. Therefore, our method can enable automatic screening of SPDS inhibitors from large numbers of samples.  相似文献   

4.
Atezolizumab (ATZ) is a human monoclonal antibody, which has been granted multiple approvals from the US Food and Drug Administration (FDA) for the immunotherapy of different types of cancer. This study describes the prototype of a time-resolved fluoroimmunoassay (TRFIA) for the quantitation of ATZ in plasma. The assay involved the non-competitive binding of ATZ to its specific antigen [programmed death-ligand 1 (PD-L1) protein]. The immune complex formed on the inner surface of the assay plate wells was quantified by anti-human secondary antibody labeled with a chelate of europium-ethylenediaminetetraacetic acid. The enhanced fluorescence signal was generated by an enhanced fluorescence solution composed of thenoyltrifluoroacetone, trioctylphosphine oxide, and Triton X-100. The conditions of the TRFIA were refined, and its optimum procedures were established. The assay was validated in accordance with the immunoassay validation guidelines, and all the validation parameters were acceptable. The working range of the assay was 20–1000 pg mL−1, and its limit of quantitation was 20 pg mL−1. The assay was applied to the quantitation of ATZ in plasma samples with satisfactory accuracy and precision. The proposed TRFIA has significant benefits over the existing methodologies for the quantitation of ATZ in clinical settings.  相似文献   

5.
The solid-phase clotting assay utilizing fibrinogen coated on the wells of a microtiter plate and peroxidase-fibrinogen in solution as a substrate for thrombin (enzyme-linked coagulation assay, ELCA) has been modified for use as an immunoassay. Direct inhibition of factors II, VII, and X by polyclonal (rabbit) antibodies and of factor X by monoclonal antibodies has been demonstrated at high dilution of these antibodies and detection of the specific factors using ELCA. Using plates coated with a second antibody (goat anti-mouse IgG) as well as fibrinogen, monoclonal antibodies to factors X and VII were measured by binding the active factor to the plate and detection of the bound factor using ELCA. The assay was very sensitive, permitting the detection of as little as 0.2 ng/ml (30 pg/assay) of monoclonal antibody, or less than 0.4 ng/ml (60 pg/assay) of factor Xa. When plates were coated with monoclonal antibody to factor X and fibrinogen, the assay permitted the identification of distinct epitope specificities for two monoclonal antibodies to factor X by distinct competition of the monoclonal antibodies added in the solution phase for binding of factor Xa to the plate. This assay could be applied generally for immunoassay of clotting factors, and could have application in general as an immunoassay amplification system.  相似文献   

6.
Progesterone has been assayed in several serum samples by a time-resolved fluoroimmunoassay (TR-FIA). The solid phase was 11 alpha-hydroxyprogesterone hemisuccinate bound covalently to ovalbumin and adsorbed on wells of polystyrene. The assay was based on competitive reaction of solid phase-bound hormone and samples with specific antibody labelled in situ with protein-A prelabelled with europium. The bound Eu was dissociated from the solid phase by an enhancement solution and measured by time-resolved fluorometry. The coefficient of correlation between TR-FIA and RIA was 0.97.  相似文献   

7.
A mixed-phase immunoassay based on simultaneous binding of an antibody to its fluorescently tagged peptide epitope and a PNA conjugate of the same peptide has been developed. As a fluorescent marker, a europium(III) chelate allowing time-resolved measurement from a single particle has been employed. The ternary complex formed in solution is immobilized by Watson-Crick base-pairing to a microparticle bearing a PNA sequence complementary to that present in the complex. The concentration of the antibody in the sample may then be determined by a single particle measurement. Accordingly, different antibodies may in principle be addressed by sequence-specific hybridization to different categorized microparticles.  相似文献   

8.
A rapid and sensitive two‐step time‐resolved fluorescence immunoassay (TRFIA) was developed for the detection of Shiga toxin 2 (Stx2) and its variants in Shiga toxin‐producing Escherichia coli (STEC) strains. In sandwich mode, a monoclonal antibody against Stx2 was coated on a microtiter plate as a capture antibody. A tracer antibody against Stx2 labeled with europium(III) (Eu3+) chelate was then used as a detector, followed by fluorescence measurements using time‐resolved fluorescence. The sensitivity of Stx2 detection was 0.038 ng/ml (dynamic range, 0.1–1000 ng/ml). The intra‐ and inter‐assay coefficients of variation of the assay were 3.2% and 3.6%, respectively. The performance of the established assay was evaluated using culture supernatants of STEC strains, and the results were compared to those of a common HRP (horseradish peroxidase) labeling immunosorbent assay. A polymerase chain reaction (PCR) for the detection of genes encoding Stx1 and Stx2 was used as the reference for comparison. Correlation between the Stx2‐specific TRFIA and PCR was calculated by the use of kappa statics, exhibiting a perfect level of agreement. The availability of the sensitive and reliable Stx2‐specific TRFIA method for quantifying Stx2 and its variants in STEC strains will complement bacteria isolation‐based platform and aid in the accurate and prompt diagnosis of STEC infections.  相似文献   

9.
An immunoassay based on immunomagnetic separation and time-resolved fluorometry was developed for the detection of E. coli O157:H7 in apple cider. The time-resolved fluorescent immunoassay (TRFIA) uses a polyclonal antibody bound to immunomagnetic beads as the capture antibody and the same antibody labeled with europium as the detection antibody. Cell suspensions of 10(1) to 10(8) E. coli O157:H7 and K-12 organisms per ml were used to test the sensitivity and specificity of the assay. The sensitivity of the assay was 10(3) E. coli O157:H7 cells with no cross-reaction with K-12. Pure cultures of E. coli O157:H7 (10(1) to 10(5) CFU/ml) in apple cider could be detected within 6 h, including 4 h for incubation in modified EC broth with novobiocin and 2 h for the immunoassay. When apple cider was spiked with 1 to 10(3) CFU/ml of E. coli O157:H7 and 10(6) CFU/ml of K-12, our data show that the high level of K-12 in apple cider did not impede the detection of low levels of O157:H7. The minimum detectable numbers of cells present in the initial inoculum were 10(2) and 10(1) CFU/ml after 4- and 6-h enrichment. The TRFIA provides a rapid and sensitive means of detecting E. coli O157:H7 in apple cider.  相似文献   

10.
现代荧光免疫分析技术应用及其新发展   总被引:6,自引:0,他引:6  
免疫分析作为一类特殊的试剂分析技术,已经被广泛应用于多个不同领域。作为免疫分析方法家族中的一员,现代荧光免疫分析技术在相关领域里也扮演了重要角色。现代荧光免疫分析技术主要包括荧光偏振免疫分析(FPIA)和时间分辩荧光免疫分析(TRFIA)两种技术。本文从原理角度出发,综述了FPIA和TRFIA近年来在分析领域中的应用,并且阐述了二者的一些最新发展动态。  相似文献   

11.
A rapid and sensitive time‐resolved fluoroimmunoassay (TR–FIA) based on the biotin–streptavidin amplification system was developed for the determination of diethylstilbestrol (DES). Europium‐labelled streptavidin derivatives combined with europium and anhydride of diethylene triamine penta‐acetic acid were used to label streptavidin; biotin was coupled with goat anti‐rabbit IgG to form a biotin–goat anti‐rabbit IgG bridge between streptavidin–europium and the anti‐DES antibody in the immunoassay. The DES assay was carried out by measuring the fluorescence of Eu3+–SA at 615 nm. The presented method produced a wide linear range, 0.001–1000.0 ng/mL, and a detection limit up to 0.81 pg/mL for DES. The method was applied to determine DES in serum samples, with recoveries of 97.4–107.8% and RSD 1.32–4.04%. The assay results by the present method showed that biotin–streptavidin amplified TR–FIA for DES detection; it may offer high sensitivity and promising alternative special methods in biological samples. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

12.
A method is reported to set up a standard competitive TR-FIA. A simple and inexpensive way to prepare reagents and carry out operations is presented as well, with the aim to make it possible to perform a very sensitive analytical procedure in a personalized way within a nondedicated biochemistry laboratory. This protocol is general and can be easily modified with consideration to the analytical target. Once the antibody is available, both its labeling with diethylenetriaminepentaacetic acid dianhydride and Eu3+, and the setting-up of the assay with measurement of europium ion time-resolved fluorescence in a home-made enhancement solution become feasible.  相似文献   

13.
A novel non-competitive idiometric time-resolved fluoroimmunoassay for the determination of serum progesterone was developed, based on the use of two types of anti-idiotypic antibody that recognize different epitopes within the hypervariable region of the primary antiprogesterone antibody. The first anti-idiotype, the betatype, competes with progesterone for an epitope of the primary antiprogesterone antibody at the binding site. The second anti-idiotype, the alphatype, binds to the antiprogesterone antibody in the presence of progesterone, but does not bind to the betatype antiprogesterone complex due to epitope proximity. In the present configuration, the biotinylated alphatype was captured onto anti-biotin IgG which was immobilized on microtiter wells. Reaction mixtures containing europium-labeled antiprogesterone antibody complexed sequentially with progesterone in standards or serum samples and with the betatype anti-idiotypic antibody were then reacted with the immobilized alphatype anti-idiotypic antibody. After 30 min of incubation, the fluorescence of europium is measured by time-resolved fluorescence and is proportional to the concentration of progesterone over the range 0–320 nmol/mL. The method demonstrates good sensitivity, precision, and comparability with a direct competitive radioimmunoassay. The idiometric assay for progesterone is suitable for dipstick technology and biosensors.  相似文献   

14.
A cationic detergent is proposed as suitable insulating agent for the preparation of a fluorescence enhancement solution useful for europium-based time-resolved fluoroimmunoassays. Luminescence from europium ions at concentration as low as 0.5 pmol/l can be detected in solution containing 1.6 mmol/l thenoyltrifluoroacetone, 110.5 μ mol/l Adogen 464 and 0.1% Tween 20, in the presence of 0.5 mol/l NaCl. A competitive TR-FIA for rabbit lgG is described, showing that the new enhancement solution allows a sensitivity comparable to that of the high performance LKB Wallac DELFIA.  相似文献   

15.
Chelated lanthanides such as europium (Eu) have uniquely long fluorescence emission half-lives permitting their use in time-resolved fluorescence (TRF) assays. In Förster resonance energy transfer (FRET) a donor fluorophore transfers its emission energy to an acceptor fluorophore if in sufficiently close proximity. The use of time-resolved (TR) FRET minimizes the autofluorescence of molecules present in biological samples. In this report, we describe a homogenous immunoassay prototype utilizing TR-FRET for detection of antibodies in solution. The assay is based on labeled protein L, a bacterial protein that binds to immunoglobulin (Ig) light chain, and labeled antigen, which upon association with the same Ig molecule produce a TR-FRET active complex. We show that the approach is functional and can be utilized for both mono- and polyvalent antigens. We also compare the assay performance to that of another homogenous TR-FRET immunoassay reported earlier. This novel assay may have wide utility in infectious disease point-of-care diagnostics.  相似文献   

16.
The 9-hydroxy-1,3-diazaphenoxazine-2-one unit was conjugated with the Eu3+-cyclen complex through a linker. This diazaphenoxazine group was expected as an antenna unit for the excitation of europium ion, and a selective recognition site for 8-oxo-dGTP base. Among the synthesized three derivatives, the highest fluorescence emission was obtained by the complex constructed of an ethylene linker and the cyclen unit with three N,N-dimethylacetamide groups. The Eu3+-cyclen complex exhibited a selective response to the 8-oxo-dGTP in aqueous media by a time-resolved fluorescence assay.  相似文献   

17.
A new and highly sensitive enzyme immunoassay of cortisol was established using horseradish peroxidase as the label. Separation of free and bound cortisol was effected by insolubilized anti-cortisol antibody which was prepared by coupling the purified immunoglobulin G of antiserum with Sepharose 4B. The enzyme activity was measured by the chemiluminescence reaction using luminol and hydrogen peroxide as substrate. The faint chemiluminescence was measured by a photon counter. Comparison of assay results obtained by radioimmunoassay and this enzyme immunoassay showed excellent agreement of results in all cases (r = 0.913). The detection limit of cortisol was about 10 pg per assay tube. This enzyme immunoassay is applicable to the routine determination of plasma cortisol.  相似文献   

18.
The authors have previously reported a homogeneous time-resolved fluorescence proximity immunoassay for estradiol. The assay was based on luminescence resonance energy transfer between a long lifetime fluorescent europium(III) chelate-dyed nanoparticle donor and a short lifetime, near-infrared fluorescent acceptor. The energy transfer prolonged the lifetime of the sensitized acceptor emission, and the fluorescence of the acceptor was measured using a time-resolved detection. The developed immunoassay was employed to screen inhibitors for enzyme 17beta-hydroxysteroid dehydrogenase type 1. The enzyme overexpressed in MCF-7 cells catalyzed a reversible conversion of estroneto17beta-estradiol. The inhibition efficiency of the tested molecule was obtained by comparing the final concentration of converted estradiol after 60 min of conversion reaction in a sample and in a conversion control not containing an inhibitor. The Zbeta factor calculated using the E2 concentrations of the homogeneous assay was 0.64, demonstrating a relatively good performance of the assay. The results from the homogeneous assay were comparable with the results obtained using radioactively labeled estrone as a substrate and high-performance liquid chromatography (HPLC) separation of estrone and converted estradiol after the enzyme reaction. Thus, this homogeneous assay can simplify the primary screening of potential new drug molecules by replacing a tedious radiometric HPLC method.  相似文献   

19.
Europium has been used as a label in immunoassays as it can be measured with high sensitivity by means of time-resolved fluorometry. Here we have used streptavidin labeled with europium chelates in the detection of adenovirus type 2 DNA bound to microtiter wells after hybridization with a biotinylated probe. The method gave quantitative results and a sensitivity of about 10 pg of the specific DNA.  相似文献   

20.
A novel europium ligand 2, 2’, 2’’, 2’’’-(4, 7-diphenyl-1, 10-phenanthroline-2, 9-diyl) bis (methylene) bis (azanetriyl) tetra acetic acid (BC-EDTA) was synthesized and characterized. It shows an emission spectrum peak at 610 nm when it is excited at 360 nm, with a large Stock shift (250 nm). It is covalently coated on the surface of a bare silica nanosphere containi free amino groups, using 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide hydrochloride and N-Hydroxysuccinimide. We also observed an interesting phenomenon that when BC-EDTA is labeled with a silica nanosphere, the chelate shows different excitation spectrum peaks of about 295 nm. We speculate that the carboxyl has a significant influence on its excitation spectrum. The BC-EDTA/Eu3+coated nanosphere could be used as a fluorescent probe for time-resolved fluorescence immunoassay. We labeled the antibody with the fluorescent nanosphere to develop a nanosphere based hepatitis B surface antigen as a time-resolved fluorescence immunoassay reagent, which is very easy to operate and eliminates potential contamination of Eu3+ contained in the environment. The analytical and functional sensitivities are 0.0037 μg/L and 0.08 μg/L (S/N≥2.0) respectively. The detection range is 0.08-166.67 μg/L, which is much wider than that of ELISA (0.2-5μg/L). It is comparable to the commercial dissociation-enhanced lanthanide fluoro-immunoassay system (DELFIA) reagents (0.2-145μg/L). We propose that it can fulfill clinical applications.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号