首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
《Biomarkers》2013,18(2):140-148
Blood levels of cyto- and chemokines might reflect immune deregulations which might be related to lymphomagenesis. Potential utility of stored blood samples of a prospective cohort was evaluated by the effect of different blood sample types and freeze-thaw cycles on analyte levels. Bead-based immunoassays were performed on two fresh samples (serum, citrate and heparin plasma) of 10 asymptomatic adults collected 14 days apart and on aliquots of the first samples which were put through one to three freeze-thaw cycles to measure 11 cytokines, four chemokines and two adhesion molecules. Median coefficients of variation (CVs) of the measured analytes were 20%, 24% and 32% in serum, citrate and heparin plasma, respectively. Strong correlations (rank correlation coefficient 0.74–0.98) were observed between sample types, although small differences in analyte levels were observed for most analytes. Freeze-thaw cycles did not markedly change analyte levels. Our study supports the use of this assay among asymptomatic subjects in epidemiological studies.  相似文献   

2.
Concerns in pre-analytical handling of urine samples are discussed using a new KDR kinase inhibitor, 3-[5-(4-methanesulfonyl-piperazin-1-ylmethyl)-1H-indol-2-yl]-1H-quinolin-2-one (compound A), as an example of a case where high light sensitivity and low analyte recovery (high affinity for container surface) were found. The absence of these problems in plasma samples may be a result of the plasma protein content. Low recovery of the analyte from urine can be remedied by either changing the container or by using additives, such as bovine serum albumin (BSA) or non-ionic surfactant Tween-20. In the case of compound A, changing containers (polypropylene versus glass vial) or addition of BSA did bring analyte recovery up to 80%. However, the addition of 0.2% Tween-20 into urine quality controls (QCs) gave more than 95% analyte recovery, indicating effective reduction of analyte loss to the surface of containers. The urine assay using mixed-mode SPE and LC-MS/MS was not affected significantly by introducing Tween-20 into the samples. The mean SPE extraction recovery was 68.4% and matrix suppression of ionization on MS was less than 8% at all analyte concentrations. The linear range of the calibration curve was 0.5-400 ng/mL on PE Sciex API 3000 LC-MS/MS system. The assay intraday accuracy and precision were 92.1-104.8% and <4.2% (%CV), respectively. Urine QC samples, containing 0.2% Tween-20, gave excellent recovery after three cycles of freeze and thaw. Since analyte loss to its urine container surface is not unique to compound A (M. Schwartz, W. Kline, B. Matuszewski, Anal. Chim. Acta 352 (1997) 299-307; A.L. Fisher, E. DePuy, T. Shih, R. Stearns, Y. Lee, K. Gottesdiener, S. Flattery, M. De Smet, B. Keymeulen, D.G. Musson, J. Pharm. Biomed. Anal. 26 (2001) 739-752), we suggest an evaluation of the potential problem in the early stages of urine assay development to ensure reliable quantitation of analytes. The addition of Tween-20 can serve as a useful analytical tool to other analytes with similar situations.  相似文献   

3.
High-performance liquid chromatography was used to assay serum acid and alkaline phosphatase. Samples were incubated with adenosine-5′-monophosphoric acid (AMP) in a buffer of required pH, 5′-nucleotidase was inhibited with Ni2+ ions, and the phosphatase activity was determined by measuring the concentration of the reaction product, adenosine. The analysis time, after the incubation is terminated, is short (7 min), and the assay is quantitative and reproducible. Complete separation of the reaction product from the substrate and the naturally occurring serum constituents and the high sensitivity of the ultra-violet detection system eliminate some of the problems commonly encountered in spectrophotometric assays.  相似文献   

4.
This study describes the baseline haematology and serum chemistry values found in non-pregnant, pregnant (gestational days [GD] 2-21) and lactating (postnatal days 1-9) Sprague Dawley rats (n = 3-10/day) from the NCTR breeding colony of Crl:COBS CD(SD)BR strain. Maternal body weights on GD0 ranged from 250 to 300 g. Multiple analytes were measured in both whole blood and serum of dams. Amniotic fluid, fetal serum, and postnatal pup serum analyte values were also acquired. Maternal blood was collected from the heart under subterminal carbon dioxide (CO2) anaesthesia. Most pregnant dam blood values were not appreciably different from values for non-pregnant dams until near term; near-term values for some analytes (red blood cells, haemoglobin, haematocrit, mean corpuscular haemoglobin concentration, alkaline phosphatase, albumin, total protein, glucose, total bilirubin, sodium, and chloride) decreased but returned to near-normal values soon after delivery. The most dramatic change was a three-fold elevation of serum triglyceride levels near term with a subsequent decrease at birth. Most serum chemistry analytes measured in progeny increased after birth except for alkaline phosphatase, calcium and potassium levels which decreased.  相似文献   

5.
Introduction – To ensure food safety, accurate knowledge of the levels of several trace elements is necessary. This is also true for natural products of plants and resins used for human consumption or therapeutic treatment, like the mastic gum of Pistacia lentiscus. The rapid analysis of gum and resin matrices is a challenge because there are problems with the decomposition of such complicated matrices. Objective – To develop an efficient multielemental analytical method for the determination of trace elements and to compare different procedures for analyte extraction when microwave‐assisted digestion is applied. Methodology – The inductively coupled plasma atomic emission spectrometric (ICP‐AES) technique was applied and the optimum ICP conditions like radiofrequency power, argon flow rate and nebuliser sample uptake flowrate were found. The microwave‐assisted procedure was compared with that with conventional heating. Since mastic and resinous materials are difficult for dissolution and extraction of trace element, influential acid mixtures containing hydrofluoric acid proved to be capable of quantitative extraction of the analytes. Results – The digestion of mastic resin or similar matrices is significantly facilitated by using microwave radiation instead of conventional heating since the obtained recovery for several analytes is much higher. It was proved that the acid mixture of HCl–HNO3–HF was the most efficient for complete sample digestion and recovery of the analytes. Conclusions The performance characteristics of the developed method were evaluated against certified reference material and the method was proved reliable and applicable to the analysis of mastic gum and possibly to similar resinous matrices. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

6.
Biochemical testing for phaeochromocytoma is performed in diagnostic laboratories using a variety of tests with plasma, serum or 24-hour urine collections. These tests include catecholamines and their methylated metabolites - the metanephrines, either individually or in combination with their sulfated metabolites. High-performance liquid chromatography (HPLC) continues to be the dominant analytical method for biogenic amine quantitation. Chromatographic techniques are changing, with improvements in sample preparation procedures, column technology and more specific analyte detection using tandem mass spectrometry. Enrolments in quality assurance programs indicate that there are still many more laboratories in Australasia analysing urinary catecholamines than metanephrines. Nevertheless, clinical evidence and expert opinion favour metanephrines as the analytes with highest sensitivity for the detection of phaeochromocytoma. Practical issues such as better chemical stability and easier specimen collection also favour metanephrines over catecholamines. For these reasons, it is likely that laboratories increasingly will replace urine catecholamine testing with either plasma or urine metanephrines. However in interpreting positive results, the need remains to consider issues such as pre-test probability and use of potentially interfering medications.  相似文献   

7.
BackgroundBarricorTM Lithium heparin plasma tubes are new blood tubes that have been introduced to overcome the effects of gel in serum separator tubes (SST) and the shortcomings of standard Lithium heparin plasma. We aimed to evaluate BarricorTM tubes as an alternative to serum separator tubes and compare the stability between the tubes.MethodsForty-four paired samples were collected using both BarricorTM and SST. We compared five analytes at baseline (<6 h) and after every 24 h using the PassingBablok and Bland-Altman plots. Aspartate aminotransferase (AST), potassium (K), phosphate (PO4) , lactate dehydrogenase (LDH), and creatinine were analysed in both tubes. We calculated the percentage difference for each analyte between the baseline and time intervals to assess analyte stability. The percentage difference was compared to the desirable specification for bias and reference change value (RCV).ResultsAll analytes were comparable at baseline. Statistical differences (p<0.001) became evident after 24 h. PO4, K, and creatinine had a mean difference that exceeded the desirable specification for bias (-9.59%, - 9.35%, and -4.59%, respectively). Potassium was stable up to 24 h in both tubes. LDH showed better stability in SST (144 h vs 96 h). PO4 concentrations were more stable in both tubes with the SST (96 h vs 72 h). Creatinine and AST had the longest stability in both tubes compared to other analytes (144 h).ConclusionsData demonstrated variability and similarities in analyte concentrations and stability, respectively, in both tubes.  相似文献   

8.
The pharmacokinetic studies of fenofibrate require a rapid, selective and robust method to allow the determination of fenofibric acid, its active metabolite, in different biological matrixes (such as plasma, serum or urine). A new fully automated method for the determination of fenofibric acid in plasma has been developed, which involves the solid-phase extraction (SPE) of the analyte from plasma on disposable extraction cartridges (DECs) and reversed-phase HPLC with UV detection. The SPE operations were performed automatically by means of a sample processor equipped with a robotic arm (ASPEC system). The DEC filled with octadecyl silica was first conditioned with methanol and pH 7.4 phosphate buffer. A 0.8-ml volume of diluted plasma sample containing the internal standard (sulindac) was then applied on the DEC. The washing step was performed with the same buffer (pH 7.4). Finally, the analytes were successively eluted with methanol (1.0 ml) and 0.04 M phosphoric acid (1.0 ml). After a mixing step, 100 μl of the resultant extract was directly introduced into the HPLC system. The liquid chromatographic (LC) separation of the analytes was achieved on a Nucleosil RP-8 stationary phase (5 μm). The mobile phase consisted of a mixture of methanol and 0.04 M phosphoric acid (60:40, v/v). The analyte was monitored photometrically at 288 nm. The method developed was validated. In these conditions, the absolute recovery of fenofibric acid was close to 100% and a linear calibration curve was obtained in the concentration range from 0.25 to 20 μg/ml. The mean RSD values for repeatability and intermediate precision were 1.7 and 3.9% for fenofibric acid. The method developed was successfully used to investigate the bioequivalence between a micronized fenofibrate capsule formulation and a fenofibrate Lidose™ formulation.  相似文献   

9.
Laboratory-based HIV tests for recent infection (TRIs), which primarily measure a specific serological biomarker(s) that distinguishes recent from long-term HIV infection, have facilitated the estimation of population-based incidence. Dried blood spots (DBS) on filter paper are an attractive sample source for HIV surveillance, given the simplified and cost-effective methods of specimen collection, storage, and shipment. Here, we evaluated the use of DBS in conjunction with an in-house multiplex TRI, the HIV-1-specific Bio-Plex assay, which measures direct antibody binding and avidity to multiple HIV-1 analytes. The assay performance was comparable between matched plasma and DBS samples from HIV-1 infected individuals obtained from diverse sources. The coefficients of variation, comparing the median antibody reactivity for each analyte between plasma and DBS, ranged from 2.78% to 9.40% and the correlation coefficients between the two sample types ranged from 0.89 to 0.97, depending on the analyte. The correlation in antibody reactivity between laboratory and site-prepared DBS for each analyte ranged from 0.87 to 0.98 and from 0.90 to 0.97 between site-prepared DBS and plasma. The correlation in assay measures between plasma and DBS indicate that the sample types can be used interchangeably with the Bio-Plex format, without negatively impacting the misclassification rate of the assay.  相似文献   

10.
The stability of total (t) and free (f) prostate-specific antigen (PSA) in male serum specimens stored at -70 degrees C or lower temperature for 4.7 to 4.9 years was studied. Until now, the stability of these analytes in serum has not been evaluated systematically beyond 2 years of storage at -70 degrees C. Aliquots of frozen serum were thawed in 2001 and 2006 and assayed for tPSA and fPSA using a Dade Behring Dimension(R) RxL analyzer and reagents. tPSA values ranged from 0.07 to 69.94 and 0.00 to 69.83 ng/mL in 2001 and 2006, respectively, whereas fPSA values for the tested specimens ranged from 0.02 to 5.72 and 0.00 to 5.92, respectively. Deming regression analyses showed agreement in assay values over time as tPSA values yielded a slope of 1.0112 and a y-intercept of 0.0195; fPSA values produced a slope 1.0538 and a y-intercept of -0.0442; f/tPSA values yielded a slope of 0.9631 and a y-intercept of 0.1195. A Bland-Altman analysis of the data demonstrated analyte and ratio stability over this time period. We conclude that serum, when collected properly and stored at -70 degrees C or lower temperature, may be used for tPSA and fPSA clinical studies for at least 5 years after collection.  相似文献   

11.
The time-dependent relationship of corticosterone, lipids and cholesterol over a 48-hr period was studied in the adrenals and blood of rats. In addition an attempt was made to determine whether there was a reciprocal dependence among these compounds and also a correlation between corticosterone and cholesterol in the adrenals and blood.

Corticosterone and cholesterol exhibit a circadian rhythm in the adrenals and blood. The same is true for lipids in the serum. A reciprocal dependence between the compounds in the adrenals and blood could not be demonstrated. Only the time-dependent processes of the corticosterone content in the adrenals and plasma are well correlated with each other. High levels of these steroids in the adrenals are associated with high levels of these steroids in the plasma and vice versa.

An inverse correlation between corticosterone and cholesterol exists in the adrenals and in blood. Maximal levels of corticosterone correspond to minimal levels of cholesterol and vice versa.  相似文献   

12.
Four different immunoassay and antibody microarray methods performed at four different sites were used to measure the levels of a broad range of proteins (N = 323 assays; 39, 88, 168, and 28 assays at the respective sites; 237 unique analytes) in the human serum and plasma reference specimens distributed by the Plasma Proteome Project (PPP) of the HUPO. The methods provided a means to (1) assess the level of systematic variation in protein abundances associated with blood preparation methods (serum, citrate-anticoagulated-plasma, EDTA-anticoagulated-plasma, or heparin-anticoagulated-plasma) and (2) evaluate the dependence on concentration of MS-based protein identifications from data sets using the HUPO specimens. Some proteins, particularly cytokines, had highly variable concentrations between the different sample preparations, suggesting specific effects of certain anticoagulants on the stability or availability of these proteins. The linkage of antibody-based measurements from 66 different analytes with the combined MS/MS data from 18 different laboratories showed that protein detection and the quality of MS data increased with analyte concentration. The conclusions from these initial analyses are that the optimal blood preparation method is variable between analytes and that the discovery of blood proteins by MS can be extended to concentrations below the ng/mL range under certain circumstances. Continued developments in antibody-based methods will further advance the scientific goals of the PPP.  相似文献   

13.
Molecular cruciforms are X-shaped systems in which two conjugation axes intersect at a central core. If one axis of these molecules is substituted with electron-donors, and the other with electron-acceptors, cruciforms'' HOMO will localize along the electron-rich and LUMO along the electron-poor axis. This spatial isolation of cruciforms'' frontier molecular orbitals (FMOs) is essential to their use as sensors, since analyte binding to the cruciform invariably changes its HOMO-LUMO gap and the associated optical properties. Using this principle, Bunz and Miljanić groups developed 1,4-distyryl-2,5-bis(arylethynyl)benzene and benzobisoxazole cruciforms, respectively, which act as fluorescent sensors for metal ions, carboxylic acids, boronic acids, phenols, amines, and anions. The emission colors observed when these cruciform are mixed with analytes are highly sensitive to the details of analyte''s structure and - because of cruciforms'' charge-separated excited states - to the solvent in which emission is observed. Structurally closely related species can be qualitatively distinguished within several analyte classes: (a) carboxylic acids; (b) boronic acids, and (c) metals. Using a hybrid sensing system composed from benzobisoxazole cruciforms and boronic acid additives, we were also able to discern among structurally similar: (d) small organic and inorganic anions, (e) amines, and (f) phenols. The method used for this qualitative distinction is exceedingly simple. Dilute solutions (typically 10-6 M) of cruciforms in several off-the-shelf solvents are placed in UV/Vis vials. Then, analytes of interest are added, either directly as solids or in concentrated solution. Fluorescence changes occur virtually instantaneously and can be recorded through standard digital photography using a semi-professional digital camera in a dark room. With minimal graphic manipulation, representative cut-outs of emission color photographs can be arranged into panels which permit quick naked-eye distinction among analytes. For quantification purposes, Red/Green/Blue values can be extracted from these photographs and the obtained numeric data can be statistically processed.  相似文献   

14.
Brucellosis is a zoonotic disease that is encountered in sheep rather frequently. In this study, 100 sheep diagnosed with brucellosis that had aborts and 40 healthy sheep were used as materials. Analyses for Cu, Zn, Fe, Cr, Ca, Mg, and K were performed with the atomic absorption spectrophotometric method on blood collected from vena jugularis of all the sheep and rheumatoid factor levels were determined by the nephelometry method. Although it was found that Cu, Ca, and rheumatoid factor values in the sera of the sheep with brucellosis were high when compared to the control group (p<0.001, p<0.05, p<0.001, respectively), their serum Zn values were low (p<0.05). No significant changes in serum Cr, Fe, K, and Mg levels were found.  相似文献   

15.
A liquid chromatography–tandem mass spectrometry (LC–MS–MS) method for the simultaneous determination of a new potent motilin receptor agonist as erythromycin derivative, EM574 (erythromycin derivative), and its three metabolites, M-IV, M-V and M-VI, in human plasma was developed. The internal standards (I.S.s) used were deuterated EM574, M-IV and M-V. For the quantitation of M-VI, deuterated M-V was used. The analytes and I.S. were extracted from plasma samples with diethyl ether at neutral pH. A turbo ion spray interface was used as the ion source of LC–MS–MS, and the analysis was performed in the selected reaction monitoring mode. The lower quantitation limits for all the analytes were 0.05 ng/ml when 0.2 ml of plasma was used, and the standard curves were linear in the range 0.05 to 20 ng/ml. The method was precise; the intra- and inter-day precisions of the method were not more than 19.8% for all the analytes. The accuracy of the method was good with the deviations between added and calculated concentrations of each analyte being typically within ±11.2%.  相似文献   

16.
A system for isolating and measuring up to 30 analytes in a single biological sample is described. The system is based on recycling a pre-labeled sample through an array of capillary immunoaffinity columns, each packed with glass beads, coated with a different antibody, thus enabling each column to isolate and extract a single analyte. Detection of the bound analytes is achieved by laser-induced fluorescence (LIF), using a laboratory-built scanning detector coupled to a fiber-optic spectrometer. The array can be regenerated up to 200 times, provided a suitable temperature is maintained. The individual immunoaffinity columns are able to bind between 2.9 and 3.6 ng of analyte, depending upon the individual column, with lower limits of detection (LOD) in the order of 1.6-2.8 pg/ml. The inter- and intra-assay coefficients of variation (CV) for all 30 columns in the array were less than 6.03+/-0.33 at analyte concentrations of 100 pg/ml. Comparison to standard enzyme-immunoassays demonstrated r(2) values in the range of 0.9151-0.9855 when analyzed by least-squares linear regression.  相似文献   

17.
A fast and sensitive LC-MS/MS method for the quantitative analysis of seven steroid hormones in 150 μl of human serum was developed and validated. The following compounds were included: 17α-hydroxypregnenolone, 17α-hydroxyprogesterone, androstenedione, dehydroepiandrosterone, testosterone, pregnenolone, and progesterone. Individual stable isotope-labeled analogues were used as internal standards. Sample preparation was performed by liquid-liquid extraction, followed by oxime derivatization to improve the ionization efficiency of the analytes. In contrast to the common derivatization-based methods, the reaction was incorporated into the sample preparation process and the only additional step due to the derivatization was a short heating of the autosampler vials before the sample injection. Chromatographic separation was achieved on a reversed-phase column using a methanol-water gradient. For the analyte detection, a triple quadrupole instrument with electrospray ionization was used. Total run time was 7.0 min and the lower limits of quantification were in the range of 0.03-0.34 nM (0.01-0.10 ng/ml), depending on the analyte. The method was validated using human serum samples from both sexes and applied for the serum steroid profiling of endometriosis patients.  相似文献   

18.

Background

Sex is an important factor in the prevalence, incidence, progression, and response to treatment of many medical conditions, including autoimmune and cardiovascular diseases and psychiatric conditions. Identification of molecular differences between typical males and females can provide a valuable basis for exploring conditions differentially affected by sex.

Methodology/Principal Findings

Using multiplexed immunoassays, we analyzed 174 serum molecules in 9 independent cohorts of typical individuals, comprising 196 males and 196 females. Sex differences in analyte levels were quantified using a meta-analysis approach and put into biological context using k-means to generate clusters of analytes with distinct biological functions. Natural sex differences were established in these analyte groups and these were applied to illustrate sexually dimorphic analyte expression in a cohort of 22 males and 22 females with Asperger syndrome. Reproducible sex differences were found in the levels of 77 analytes in serum of typical controls, and these comprised clusters of molecules enriched with distinct biological functions. Analytes involved in fatty acid oxidation/hormone regulation, immune cell growth and activation, and cell death were found at higher levels in females, and analytes involved in immune cell chemotaxis and other indistinct functions were higher in males. Comparison of these naturally occurring sex differences against a cohort of people with Asperger syndrome indicated that a cluster of analytes that had functions related to fatty acid oxidation/hormone regulation was associated with sex and the occurrence of this condition.

Conclusions/Significance

Sex-specific molecular differences were detected in serum of typical controls and these were reproducible across independent cohorts. This study extends current knowledge of sex differences in biological functions involved in metabolism and immune function. Deviations from typical sex differences were found in a cluster of molecules in Asperger syndrome. These findings illustrate the importance of investigating the influence of sex on medical conditions.  相似文献   

19.
Several new plasma protein biomarkers have been associated with increased risk of cardiovascular events. It would be of great value if sets of these markers could be measured in a multiplexed format at point-of-care settings. A major challenge is the extremely wide concentration range in which different plasma biomarkers are present. Two promising biomarkers for cardiac risk prediction are C-reactive protein (CRP) and N-terminal pro-brain natriuretic peptide (NTproBNP). The concentrations of these markers can differ by more than six orders of magnitude. Here we present a chip-based multiplexed assay for CRP and NTproBNP. The high-concentration analyte, CRP, is analyzed in a competitive format, whereas the low-concentration analyte, NTproBNP, is analyzed in a sandwich format. This allows concurrent measurement of the two analytes in a single multiplexed assay. The dynamic ranges for the two assays were optimized to match the relevant serum concentration ranges; thus, no dilutions were needed. Both assays exhibit good precision (5–15% in the clinically relevant concentration ranges), and the limit of detection for the NTproBNP assay was 5 ng/L. Patient plasma samples were used for comparison with clinical methods, resulting in coefficients of determination (R2) of 0.9762 and 0.9606 for NTproBNP and CRP, respectively.  相似文献   

20.
The quality of the laboratory diagnostic approach in farm animals can be severely affected by pre-analytical factors of variation. They induce increase/decrease of biochemical and hematological analyte concentrations and, as a consequence, they may cause unsuitable conclusions and decisions for animal health management and research projects. The pre-analytical period covers the preparation of sampling, the sampling procedure itself, as well as all specimen handling until the beginning of the specific laboratory analysis. Pre-analytical factors may have either an animal-related or a technique-related background. Animal-related factors cover daytime/season, meals/fasting, age, gender, altitude, drugs/anesthesia, physical exercise/stress or coinfection. Technique-related factors are the choice of the tube including serum v. plasma, effects of anticoagulants/gel separators, the anticoagulant/blood ratio, the blood collection procedure itself, specimen handling, contamination, labeling, storage and serum/plasma separation, transportation of the specimen, as well as sample preparation before analysis in the laboratory. It is essential to have proper knowledge about the importance and source of pre-analytical factors to alter the entire diagnostic process. Utmost efforts should be made to minimize controllable factors. Analytical results have to be evaluated with care considering that pre-analytical factors of variation are possible causes of misinterpretation.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号