首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
AIMS: Four inhalational anthrax cases occurred in a large mail processing and distribution center in Washington, DC, after envelopes containing Bacillus anthracis spores were processed. This report describes the results of sampling for B. anthracis spores during investigations conducted in October and December 2001. METHODS AND RESULTS: Wet swabs, wet wipes, vacuum sock, and air-filter samples were collected throughout the facility to characterize the extent of building contamination. The results showed widespread contamination of B. anthracis spores, particularly associated with one delivery bar code sorter (DBCS) machine that had sorted the spore-containing envelopes and an area where the envelopes were handled by postal workers. Spore concentrations decreased as distance from the DBCS machine increased, but spores were widely dispersed into surrounding areas. CONCLUSION: The spatial distribution of culture positive samples was closely related to the work areas of the inhalational anthrax cases and supported epidemiological evidence that the workers became ill from exposure to B. anthracis spores in areas where the contaminated envelopes had travelled. SIGNIFICANCE AND IMPACT OF THE STUDY: The results of this investigation were used to guide decontamination efforts and provided baseline spore concentrations for follow-up measurements after the building had been cleaned. Implementing methods to reduce aerosolization and dispersion of dust within the facility would reduce postal workers' potential exposures to bioterrorism agents.  相似文献   

2.
The discovery of a letter intentionally filled with dried Bacillus anthracis spores in the office of a United States senator prompted the collection and quarantine of all mail in congressional buildings. This mail was subsequently searched for additional intentionally contaminated letters. A microbiological sampling strategy was used to locate heavy contamination within the 642 separate plastic bags containing the mail. Swab sampling identified 20 bags for manual and visual examination. Air sampling within the 20 bags indicated that one bag was orders of magnitude more contaminated than all the others. This bag contained a letter addressed to Senator Patrick Leahy that had been loaded with dried B. anthracis spores. Microbiological sampling of compartmentalized batches of mail proved to be efficient and relatively safe. Efficiency was increased by inoculating culture media in the hot zone rather than transferring swab samples to a laboratory for inoculation. All mail sampling was complete within 4 days with minimal contamination of the sampling environment or personnel. However, physically handling the intentionally contaminated letter proved to be exceptionally hazardous, as did sorting of cross-contaminated mail, which resulted in generation of hazardous aerosol and extensive contamination of protective clothing. Nearly 8 x 10(6) CFU was removed from the most highly cross-contaminated piece of mail found. Tracking data indicated that this and other heavily contaminated envelopes had been processed through the same mail sorting equipment as, and within 1 s of, two intentionally contaminated letters.  相似文献   

3.
AIMS: To determine the irradiation dose necessary to reduce the populations of Bacillus anthracis spores in a dry medium in postal envelopes. METHODS AND RESULTS: Bacillus anthracis Sterne 34F2 spores were dispersed in non-fat dry milk and then placed into standard business postal envelopes. The spores were treated with a sequence of irradiation doses to determine the decimal reduction value (D10) in kiloGrays (kGy). The average D10 value was 3.35 +/- 0.02 kGy. CONCLUSIONS: An irradiation dose of 40.2 kGy would be required to result in a process equivalent to the thermal canning process (12 D10 reduction) to eliminate Clostridium botulinum spores. SIGNIFICANCE AND IMPACT OF THE STUDY: Irradiation is an effective means of reducing or eliminating B. anthracis spores in a dry medium in postal envelopes.  相似文献   

4.
This work was initiated to address the gaps identified by Congress regarding validated biothreat environmental sampling and processing methods. Nine Laboratory Response Network-affiliated laboratories participated in a validation study of a cellulose sponge wipe-processing protocol for the recovery, detection, and quantification of viable Bacillus anthracis Sterne spores from steel surfaces. Steel coupons (645.16 cm(2)) were inoculated with 1 to 4 log(10) spores and then sampled with cellulose sponges (Sponge-Stick; 3M, St. Paul, MN). Surrogate dust and background organisms were added to the sponges to mimic environmental conditions. Labs processed the sponges according to the provided protocol. Sensitivity, specificity, and mean percent recovery (%R), between-lab variability, within-lab variability, and total percent coefficient of variation were calculated. The mean %R (standard error) of spores from the surface was 32.4 (4.4), 24.4 (2.8), and 30.1 (2.3) for the 1-, 2-, and 4-log(10) inoculum levels, respectively. Sensitivities for colony counts were 84.1%, 100%, and 100% for the 1-, 2-, and 4-log(10) inocula, respectively. These data help to characterize the variability of the processing method and thereby enhance confidence in the interpretation of the results of environmental sampling conducted during a B. anthracis contamination investigation.  相似文献   

5.
In response to a bioterrorism attack in the Washington, D.C., area in October 2001, a mobile laboratory (ML) was set up in the city to conduct rapid molecular tests on environmental samples for the presence of Bacillus anthracis spores and to route samples for further culture analysis. The ML contained class I laminar-flow hoods, a portable autoclave, two portable real-time PCR devices (Ruggedized Advanced Pathogen Identification Device [RAPID]), and miscellaneous supplies and equipment to process samples. Envelopes and swab and air samples collected from 30 locations in the metropolitan area once every three days were subjected to visual examination and DNA extraction, followed by real-time PCR using freeze-dried, fluorescent-probe-based reagents. Surface swabs and air samples were also cultured for B. anthracis at the National Veterinary Service Laboratory (NVSL) in Ames, Iowa. From 24 October 2001 to 15 September 2002, 2,092 pieces of mail were examined, 405 real-time PCR assays were performed (comprising 4,639 samples), and at the NVSL 6,275 samples were subjected to over 18,000 platings. None of the PCR assays on DNA extracted from swab and air samples were positive, but viable spores were cultured from surface swabs taken from six locations in the metropolitan area in October, November, and December 2001 and February, March, and May 2002. DNA extracted from these suspected B. anthracis colonies was positive by real-time and conventional PCRs for the lethal factor, pXO1, and for capA and vrr genes; sequence analysis of the latter amplicons indicated >99% homology with the Ames, vollum, B6273-93, C93022281, and W-21 strains of B. anthracis, suggesting they arose from cross-contamination during the attack through the mail. The RAPID-based PCR analysis provided fast confirmation of suspect colonies from an overnight incubation on agar plates.  相似文献   

6.
Recent bioterrorism concerns have prompted renewed efforts towards understanding the biology of bacterial spore resistance to radiation with a special emphasis on the spores of Bacillus anthracis. A review of the literature revealed that B. anthracis Sterne spores may be three to four times more resistant to 254-nm-wavelength UV than are spores of commonly used indicator strains of Bacillus subtilis. To test this notion, B. anthracis Sterne spores were purified and their UV inactivation kinetics were determined in parallel with those of the spores of two indicator strains of B. subtilis, strains WN624 and ATCC 6633. When prepared and assayed under identical conditions, the spores of all three strains exhibited essentially identical UV inactivation kinetics. The data indicate that standard UV treatments that are effective against B. subtilis spores are likely also sufficient to inactivate B. anthracis spores and that the spores of standard B. subtilis strains could reliably be used as a biodosimetry model for the UV inactivation of B. anthracis spores.  相似文献   

7.
AIMS: The Cepheid GeneXpert is a four-site, automated sample preparation and real-time PCR detection system. In this study, the capability of the GeneXpert to isolate and detect nucleic acid from Bacillus anthracis Ames spores was assessed. METHODS AND RESULTS: A four-plex, dried-down bead cartridge containing PCR reagents specific for the pXO1 and pXO2 plasmids as well as sample processing and inhibition controls was evaluated. For B. anthracis Ames spores harbouring pXO1 and pXO2, samples containing 68 CFU per ml (148 spores per ml) were positive in all four replicates. A limited cross-reactivity panel, which included closely related Bacillus species, was also tested to determine the specificity of the pXO1 and pXO2 assays. No cross-reactivity occurred. Further, B. anthracis Sterne spore samples were analysed to compare results when processed using the GeneXpert to those run directly on the Cepheid SmartCycler without sample processing. The GeneXpert detection capability was three logs lower than the SmartCycler indicating the benefit of incorporating a nucleic acid extraction procedure. CONCLUSIONS: This study demonstrates that the GeneXpert is a rapid and reliable system for simultaneously detecting the B. anthracis virulence plasmids pXO1 and pXO2. SIGNIFICANCE AND IMPACT OF THE STUDY: The GeneXpert is the only platform currently available that is capable of both nucleic acid purification and real-time PCR detection enclosed within a single system. Further, all sample manipulations are automated, thus reducing errors associated with manual processing.  相似文献   

8.
Typical real-time PCR methods used to identify Bacillus anthracis do not distinguish between viable and non-viable spores, which would be critical in any first response and remediation scenarios. This study combined both real-time PCR, using primers specifically designed for gamma phage, with the highly specific gamma phage amplification into one simple assay to indirectly detect Bacillus anthracis. Since the amplification of gamma phage only occurs in the presence of a suitable host, the detection of increasing concentrations of progeny gamma phage DNA using real-time PCR implies the presence of viable Bacillus anthracis cells. This method detected a starting Bacillus anthracis concentration of 207 cfu/mL, equivalent to less than one cell in 20 microL, in less than 5 h.  相似文献   

9.
Currently available detectors for spores of Bacillus anthracis, the causative agent of anthrax, are inadequate for frontline use and general monitoring. There is a critical need for simple, rugged, and inexpensive detectors capable of accurate and direct identification of B. anthracis spores. Necessary components in such detectors are stable ligands that bind tightly and specifically to target spores. By screening a phage display peptide library, we identified a family of peptides, with the consensus sequence TYPXPXR, that bind selectively to B. anthracis spores. We extended this work by identifying a peptide variant, ATYPLPIR, with enhanced ability to bind to B. anthracis spores and an additional peptide, SLLPGLP, that preferentially binds to spores of species phylogenetically similar to, but distinct from, B. anthracis. These two peptides were used in tandem in simple assays to rapidly and unambiguously identify B. anthracis spores. We envision that these peptides can be used as sensors in economical and portable B. anthracis spore detectors that are essentially free of false-positive signals due to other environmental Bacillus spores.  相似文献   

10.
A fluorescein-conjugated antibody against formalin-inactivated spores of Bacillus anthracis Vollum reacted only weakly with a variety of Bacillus species in microfluorometric immunofluorescence assays. A conjugated antibody against spores of B. anthracis Sterne showed little affinity for spores of several B. anthracis isolates including B. anthracis Vollum, indicating that more than one anthrax spore serotype exists.  相似文献   

11.
Spores of Bacillus anthracis, the causative agent of anthrax, are enclosed by an exosporium, which consists of a basal layer surrounded by a nap of hair-like filaments. The major structural component of the filaments is called BclA, which comprises a central collagen-like region (CLR) and a globular C-terminal domain. Here, the entire CLR coding sequence of BclA was removed, and the resulting protein (tBclA) produced in Escherichia coli. The crystallographic structure of tBclA was determined to 1.35 A resolution, and consists of an all-beta structure with a TNF-like jelly fold topology (12 beta-strands which form 2 beta-sheets of five strands each) consistent with previous studies on wild-type BclA. These globular domains are tightly packed into trimeric structures (surface shape complementarity; S (c) = 0.83), demonstrating that formation of the core structure of BclA is independent of the anchoring collagen-like region. A polyclonal antibody raised against tBclA recognized B. anthracis spores directly, and showed little cross-reactivity (<10%) with the spores of the closely related species Bacillus cereus and Bacillus thuringiensis, when compared to two other polyclonal antibodies raised against B. anthracis spore extracts and inactivated spores. The tBclA protein was used to purify a pool of specific antibodies from bovine colostrum whey samples from cows inoculated with the Sterne strain anthrax vaccine, which also showed reactivity with B. anthracis spores. Together, these results demonstrate that tBclA provides a safer and more effective way to the production and purification of antibodies with high binding affinity for B. anthracis spores. Biotechnol. Bioeng. 2008;99: 774-782. (c) 2007 Wiley Periodicals, Inc.  相似文献   

12.
AIMS: To compare the relative sensitivity of Bacillus anthracis and spores of other Bacillus spp. deposited on different solid surfaces to inactivation by liquid chemical disinfecting agents. METHODS AND RESULTS: We prepared under similar conditions spores from five different virulent and three attenuated strains of B. anthracis, as well as spores of Bacillus subtilis, Bacillus atrophaeus (previously known as Bacillus globigii), Bacillus cereus, Bacillus thuringiensis and Bacillus megaterium. As spore-surface interactions may bias inactivation experiments, we evaluated the relative binding of different spores to carrier materials. The survival of spores deposited on glass, metallic or polymeric surfaces were quantitatively measured by ASTM standard method E-2414-05 which recovers spores from surfaces by increasing stringency. The number of spores inactivated by each decontaminant was similar and generally within 1 log among the 12 different Bacillus strains tested. This similarity among Bacillus strains and species was observed through a range of sporicidal efficacy on spores deposited on painted metal, polymeric rubber or glass. CONCLUSIONS: The data obtained indicate that the sensitivity of common simulants (B. atrophaeus and B. subtilis), as well as spores of B. cereus, B. thuringiensis, and B. megaterium, to inactivation by products that contain either: peroxide, chlorine or oxidants is similar to that shown by spores from all eight B. anthracis strains studied. SIGNIFICANCE AND IMPACT OF THE STUDY: The comparative results of the present study suggest that decontamination and sterilization data obtained with simulants can be safely extrapolated to virulent spores of B. anthracis. Thus, valid conclusions on sporicidal efficacy could be drawn from safer and less costly experiments employing non-pathogenic spore simulants.  相似文献   

13.
AIM: To evaluate the efficacy of electrochemically activated solution (ECASOL) in decontaminating Bacillus anthracis Ames and Vollum 1B spores, with and without changing the source water hardness and final ECASOL pH. METHODS AND RESULTS: Five different ECASOL formulations were generated, in which the source water hardness and final ECASOL pH were varied, resulting in cases where significant changes in free available chlorine (FAC) and oxidative-reduction potential (ORP) were observed. B. anthracis Ames and Vollum 1B spores were suspended in the various ECASOL formulations for 30 min, and decontamination efficacy was determined; calcium hypochlorite [5% high-test hypochlorite (HTH)] was used as a positive control. The five different ECASOL formulations yielded mean FAC levels ranging from 305 to 464 ppm, and mean ORP levels ranging from +826 to +1000 mV. Exposure to all the ECASOL formulations and 5% HTH resulted in >or=7.0 log reductions in both B. anthracis Ames and Vollum 1B spores. CONCLUSIONS: The present testing demonstrated that ECASOL with a minimum of c. 300-ppm FAC levels and +800-mV ORP inactivated the B. anthracis spores in suspension, similar to 5% HTH. Significance and Impact of the Study: These results provide information for decontaminating B. anthracis Ames and Vollum 1B spores in suspension using ECASOL.  相似文献   

14.
We report here the adaptation of our electronic microchip technology towards the development of a new method for detecting and enumerating bacterial cells and spores. This new approach is based on the immuno-localization of bacterial spores captured on a membrane filter microchip placed within a flow cell. A combination of microfluidic, optical, and software components enables the integration of staining of the bacterial species with fully automated assays. The quantitation of the analyte signal is achieved through the measurement of a collective response or alternatively through the identification and counting of individual spores and particles. This new instrument displays outstanding analytical characteristics, and presents a limit of detection of approximately 500 spores when tested with Bacillus globigii (Bg), a commonly used simulant for Bacillus anthracis (Ba), with a total analysis time of only 5 min. Additionally, the system performed well when tested with real postal dust samples spiked with Bg in the presence of other common contaminants. This new approach is highly customizable towards a large number of relevant toxic chemicals, environmental factors, and analytes of relevance to clinical chemistry applications.  相似文献   

15.
Soil samples were collected from around fresh and year-old bison carcasses and areas not associated with known carcasses in Wood Buffalo National Park during an active anthrax outbreak in the summer of 2001. Sample selection with a grid provided the most complete coverage of a site. Soil samples were screened for viable Bacillus anthracis spores via selective culture, phenotypic analysis, and PCR. Bacillus anthracis spores were isolated from 28.4% of the samples. The highest concentrations of B. anthracis spores were found directly adjacent to fresh carcasses and invariably corresponded to locations where the soil had been saturated with body fluids escaping the carcass through either natural body orifices or holes torn by scavengers. The majority of positive samples were found within 2 m of both year-old and fresh carcasses and probably originated from scavengers churning up and spreading the body fluid-saturated soil as they fed. Trails of lesser contamination radiating from the carcasses probably resulted from spore dissemination through adhesion to scavengers and through larger scavengers dragging away disarticulated limbs. Comparison of samples from minimally scavenged and fully necropsied carcass sites revealed no statistically significant difference in the level of B. anthracis spore contamination. Therefore, the immediate area around a suspected anthrax carcass should be considered substantially contaminated regardless of the condition of the carcass.  相似文献   

16.
AIMS: To determine the size distribution of the spores of Bacillus anthracis, and compare its size with other Bacillus species grown and sporulated under similar conditions. METHODS AND RESULTS: Spores from several Bacillus species, including seven strains of B. anthracis and six close neighbours, were prepared and studied using identical media, protocols and instruments. Here, we report the spore length and diameter distributions, as determined by transmission electron microscopy (TEM). We calculated the aspect ratio and volume of each spore. All the studied strains of B. anthracis had similar diameter (mean range between 0.81 +/- 0.08 microm and 0.86 +/- 0.08 microm). The mean lengths of the spores from different B. anthracis strains fell into two significantly different groups: one with mean spore lengths 1.26 +/- 0.13 microm or shorter, and another group of strains with mean spore lengths between 1.49 and 1.67 microm. The strains of B. anthracis that were significantly shorter also sporulated with higher yield at relatively lower temperature. The grouping of B. anthracis strains by size and sporulation temperature did not correlate with their respective virulence. CONCLUSIONS: The spores of Bacillus subtilis and Bacillus atrophaeus (previously named Bacillus globigii), two commonly used simulants of B. anthracis, were considerably smaller in length, diameter and volume than all the B. anthracis spores studied. Although rarely used as simulants, the spores of Bacillus cereus and Bacillus thuringiensis had dimensions similar to those of B. anthracis. SIGNIFICANCE AND IMPACT OF THE STUDY: Spores of nonvirulent Bacillus species are often used as simulants in the development and testing of countermeasures for biodefence against B. anthracis. The data presented here should help in the selection of simulants that better resemble the properties of B. anthracis, and thus, more accurately represent the performance of collectors, detectors and other countermeasures against this threat agent.  相似文献   

17.
AIMS: To evaluate the decontamination of Bacillus anthracis, Bacillus subtilis, and Geobacillus stearothermophilus spores on indoor surface materials using hydrogen peroxide gas. METHODS AND RESULTS: Bacillus anthracis, B. subtilis, and G. stearothermophilus spores were dried on seven types of indoor surfaces and exposed to > or =1000 ppm hydrogen peroxide gas for 20 min. Hydrogen peroxide exposure significantly decreased viable B. anthracis, B. subtilis, and G. stearothermophilus spores on all test materials except G. stearothermophilus on industrial carpet. Significant differences were observed when comparing the reduction in viable spores of B. anthracis with both surrogates. The effectiveness of gaseous hydrogen peroxide on the growth of biological indicators and spore strips was evaluated in parallel as a qualitative assessment of decontamination. At 1 and 7 days postexposure, decontaminated biological indicators and spore strips exhibited no growth, while the nondecontaminated samples displayed growth. CONCLUSIONS: Significant differences in decontamination efficacy of hydrogen peroxide gas on porous and nonporous surfaces were observed when comparing the mean log reduction in B. anthracis spores with B. subtilis and G. stearothermophilus spores. SIGNIFICANCE AND IMPACT OF THE STUDY: These results provide comparative information for the decontamination of B. anthracis spores with surrogates on indoor surfaces using hydrogen peroxide gas.  相似文献   

18.
This project examined dry, fluidized spore reaerosolization in a heating, ventilating, and air conditioning duct system. Experiments using spores of Bacillus atrophaeus, a nonpathogenic surrogate for Bacillus anthracis, were conducted to delineate the extent of spore reaerosolization behavior under normal indoor airflow conditions. Short-term (five air-volume exchanges), long-term (up to 21,000 air-volume exchanges), and cycled (on-off) reaerosolization tests were conducted using two common duct materials. Spores were released into the test apparatus in turbulent airflow (Reynolds number, 26,000). After the initial pulse of spores (approximately 10(10) to 10(11) viable spores) was released, high-efficiency particulate air filters were added to the air intake. Airflow was again used to perturb the spores that had previously deposited onto the duct. Resuspension rates on both steel and plastic duct materials were between 10(-3) and 10(-5) per second, which decreased to 10 times less than initial rates within 30 min. Pulsed flow caused an initial spike in spore resuspension concentration that rapidly decreased. The resuspension rates were greater than those predicted by resuspension models for contamination in the environment, a result attributed to surface roughness differences. There was no difference between spore reaerosolization from metal and that from plastic duct surfaces over 5 hours of constant airflow. The spores that deposited onto the duct remained a persistent source of contamination over a period of several hours.  相似文献   

19.
We found that Congo red agar allows identification of sporulation-deficient Bacillus anthracis. Using Congo red agar, we isolated an asporogenic derivative of the protective antigen-producing strain B. anthracis delta Sterne-1(pPA102). Polymerase chain reaction and Southern hybridization analyses of DNA from the asporogenic mutant revealed that a deletion was present in spoOA, an essential gene for the initiation of sporulation. The deletion also encompassed the spoIVB homologue and a portion of the recN homologue. The avirulent spoOA strain delta Sterne-1(pPA102)CR4 is suitable for the safe production of protective antigen without endospore contamination of the vaccine production facility.  相似文献   

20.
AIMS: To evaluate the decontamination of Bacillus anthracis, Bacillus subtilis, and Geobacillus stearothermophilus spores on indoor surface materials using formaldehyde gas. METHODS AND RESULTS: B. anthracis, B. subtilis, and G. stearothermophilus spores were dried on seven types of indoor surfaces and exposed to approx. 1100 ppm formaldehyde gas for 10 h. Formaldehyde exposure significantly decreased viable B. anthracis, B. subtilis, and G. stearothermophilus spores on all test materials. Significant differences were observed when comparing the reduction in viable spores of B. anthracis with B. subtilis (galvanized metal and painted wallboard paper) and G. stearothermophilus (industrial carpet and painted wallboard paper). Formaldehyde gas inactivated>or=50% of the biological indicators and spore strips (approx. 1x10(6) CFU) when analyzed after 1 and 7 days. CONCLUSIONS: Formaldehyde gas significantly reduced the number of viable spores on both porous and nonporous materials in which the two surrogates exhibited similar log reductions to that of B. anthracis on most test materials. SIGNIFICANCE AND IMPACT OF THE STUDY: These results provide new comparative information for the decontamination of B. anthracis spores with surrogates on indoor surfaces using formaldehyde gas.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号