首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A specific and sensitive enzyme-linked immunosorbent assay (ELISA) of the "sandwich-type" for human corticosteroid-binding globulin was developed. A polyclonal rabbit anti-CBG antibody is immobilised to a microtitre plate. Following incubation of standards and samples a second monospecific rabbit anti-CBG antibody, labelled with alkaline phosphatase, is added. After colour development the microtitre plate is read at 405 nm wavelength. The assay shows good agreement to CBG binding capacity assay and commercially available RIA.  相似文献   

2.
A simple enzyme-linked immunosorbent assay (ELISA) for sex hormone-binding globulin (SHBG) has been developed. Polyclonal antibody raised to SHBG purified to homogeneity was employed. The ELISA, which may be performed in under 4 h, shows no cross-reactivity with other serum proteins, has a sensitivity of less than 1.2 fmol per sample, demonstrates excellent correlation with ligand-binding techniques (r = 0.996; p less than 0.0001), and has intra- and inter-assay coefficients of variation of between 5-9% and 7-11% respectively.  相似文献   

3.
An enzyme-linked immunosorbent assay (ELISA) for plasma testosterone   总被引:4,自引:0,他引:4  
A rapid, single extraction ELISA for testosterone in plasma is described, using a standard 96 well microtitre plate. Testosterone is covalently bonded to bovine thyroglobulin and passively adsorbed in guanidine hydrochloride to the ELISA plate, giving an immobilised antigen approach which simplifies subsequent assay standardisation for steroid hormone assays. The addition of standard, sample and first antibody (rabbit anti-testosterone), which is unique for each different assay, is followed by a general procedure which includes washing, addition of peroxidase labelled goat antirabbit IgG, further washing and finally, addition of o-phenylenediamine substrate with colour development and reading of the plate at 492 nm on an automatic ELISA processor. The ELISA assay is compared to a testosterone RIA with 125I-label and has similar specificity and precision to the latter with a quicker processing time, and is more cost effective. The added advantages that ELISA assays confer over RIAs in terms of isotope purchase and disposal make this an ideal procedure for use in a routine steroid laboratory.  相似文献   

4.
A direct ELISA for plasma cortisol is described which is carried out in a standard 96 well microtitre plate. In this ELISA cortisol-thyroglobulin conjugate is immobilised to the microtitre plate and competes with cortisol in the standard or plasma sample for antibody binding sites. Following washing the rabbit cortisol antibody bound to immobilised cortisol is incubated with peroxidase labelled goat antirabbit IgG. Following further washing o-phenylenediamine is added, colour developed, and the plate read at 492 nm on a standard ELISA plate reader. This ELISA shows good agreement with RIA and its sensitivity, specificity and precision allow its use in the routine steroid laboratory.  相似文献   

5.
6.
J G Lewis  N J Longley  P A Elder 《Steroids》1999,64(4):259-265
Four monoclonal antibodies to human sex hormone-binding globulin were raised and characterized. Three of the four antibodies recognised different antigenic determinants on SHBG. Two of the distinct antibodies were useful for Western blotting and recognized a major 48 kDa band in human plasma as well as a 46 kDa minor component. Carbohydrate residues do not form part of the antigenic determinants of these two antibodies, although one of these showed increased signal following removal of N-linked oligosaccharides. Some of the antibodies were selected to form a basis of a same-day, non-competitive, enzyme-linked immunosorbent assay (ELISA) for SHBG in plasma. The assay employs a purified IgG2a SHBG monoclonal antibody adsorbed to the wells of a microtitre plate. After blocking any further adsorption to the plate, standards or diluted patient samples were added for a 5-h incubation at room temperature, after which the plate was washed and antibody-bound SHBG was detected with an anti-SHBG IgG1 monoclonal antibody followed by peroxidase-labeled antimouse-IgG1 and o-phenylenediamine substrate. The assay correlated well with an existing 2-day ELISA for SHBG in plasma using polyclonal antibodies and also correlated with a dihydrosterone (DHT) ligand-binding assay. The monoclonal antibody-based ELISA shows excellent performance characteristics and is unaffected by added testosterone or estradiol.  相似文献   

7.
An enzyme-linked immunosorbent assay (ELISA) test has been developed for measurement of heterophile antibody. The microtiter test utilizes a bovine erythrocyte monolayer as antigen and anti-human IgM antiserum conjugated with horseradish peroxidase to measure the degree of binding of the heterophile antibody in the test serum with the erythrocytes. A single serum dilution yields quantitative results when read in a spectrophotometer. The ELISA test showed a sensitivity comparable with the immune adherence hemagglutination assay (IAHA) and other heterophile tests, good reproducibility, and high specificity.  相似文献   

8.
Antiserum (MB007) was raised in rabbits to SDS-denatured cartilage link protein in order to develop an enzyme-linked immunosorbent assay (ELISA) to quantify link protein in cartilage extracts. The antibodies were characterized by using native and denatured link protein, either as the immobilised or the inhibiting antigen in the assay, and shown to bind more effectively to denatured link protein. At low concentrations, neither hyaluronate (0-30 micrograms/ml), proteoglycan (0-50 micrograms/ml) nor hyaluronate-binding region (0-3 micrograms/ml) competitively inhibited the link protein assay. However, at higher concentrations of proteoglycan (50 micrograms/ml-4 mg/ml) and hyaluronate-binding region (3-40 micrograms/ml) inhibition was observed. A more highly purified proteoglycan and a further purified hyaluronate-binding region preparation showed identical behaviour. The inhibition produced by proteoglycan and hyaluronate-binding region occurred at approximately equivalent molar concentrations (assuming Mr of 10(6) and 7 X 10(4), respectively). These results suggest that a significant proportion of these polyclonal antibodies recognize an epitope common to link protein and hyaluronate-binding region. However, the possibility that these effects are due to contamination with covalently bound link protein cannot be excluded. Trypsinated aggregates (0-10 micrograms/ml) produced no inhibition in the link protein ELISA, but as higher concentrations the inhibition was approximately 2000-fold lower than might have been expected from the link protein concentration present. Thus, the accessibility and/or binding of the antibodies to link protein was substantially decreased, illustrating masking of the link protein antigenic sites, as found by A. Ratcliffe and T.E. Hardingham (Biochem. J. 213 (1983) 371-378). These studies indicate that link protein in tissue extracts may be quantified in the concentration range 30-200 ng/ml and in the presence of hyaluronate, proteoglycan and hyaluronate-binding region, provided that both the immobilised and extracted link proteins are denatured.  相似文献   

9.
The standard ELISA technique was improved for the detection of antigalactocerebroside antibody in biological fluid. Mouse monoclonal antigalactocerebroside antibody was used to demonstrate specificity and sensitivity of the technique. After optimization of the assay, the usefulness of this measurement for the evaluation of patients with multiple sclerosis was assessed. The presence of antigalactocerebroside antibodies in the cerebrospinal fluid of 20 patients with multiple sclerosis, 10 with other neurological diseases and 10 normal individuals was determined. All the CSF samples from normal individuals were negative. In patients with multiple sclerosis 14 of the 20 samples had elevated levels of antigalactocerebroside antibody, whereas with other neurological diseases 5 out of 10 were positive. Antigalactocerebroside levels were lower in samples from patients during an acute relapse than in those from more chronic cases. These results indicate that the presence of anti-galactocerebroside antibody in cerebrospinal fluid is not specific to MS but may reflect previous damage to myelin.Abbreviations and trivial names used ELISA Enzyme-Linked Immunosorbent Assay - CSF cerebrospinal fluid; galacto- or glucocerebroside, ceramide-1-0-beta-galactoside or-glucoside  相似文献   

10.
Optimality assessment in the enzyme-linked immunosorbent assay (ELISA)   总被引:1,自引:0,他引:1  
K F Karpinski 《Biometrics》1990,46(2):381-390
An optimality criterion is proposed for evaluating the precision of alternative designs in the enzyme-linked immunosorbent assay. Assay profiles are represented as four-parameter logistic functions with parameter estimation based on either a weighted nonlinear regression or a simple nonlinear regression after a logarithmic transformation. Assay design changes are characterized in terms of their effects on parameters in the four-parameter logistic model. General optimality results are derived for the variance of relative potency estimates in routine assay applications.  相似文献   

11.
Enumeration of rhizobia by enzyme-linked immunosorbent assay (ELISA)   总被引:1,自引:1,他引:0  
The use of the enzyme-linked immunosorbent assay (ELISA) to enumerate rhizobia in peat carrier and in soil has been investigated. The ELISA technique takes less time than the conventional plant infection technique often used to enumerate rhizobia present in the presence of other micro-organisms. A minimum of 102–103 cells are required for a detectable ELISA reaction, limiting the use of this technique when the number of rhizobia is low.  相似文献   

12.
13.
Antibodies against Mycobacterium tuberculosis antigenic glycolipids were determined by enzyme-linked immunosorbent assay (ELISA). The 720 sera were collected from adult patients under investigation, suspected with extrapulmonary tuberculosis. The test performance was estimated according to definitive diagnosis in terms of specificity, sensitivity, positive predictive value and negative predictive value. These parameters calculated on 142 sera from patients with extrapulmonary tuberculosis and on 578 sera from patients with different nontuberculosis diseases were 92%, 81.6%, 70.9% and 95.1%, respectively. The specificity decreased to 85% when tuberculosis was associated with cancer or hepatic cirrhosis. In reactivated tuberculosis the sensitivity and the positive predictive value were 86.9% and 83.3%, respectively. Our results showed that ELISA was conclusive for patients with active tuberculosis, before the initiation of the treatment. The sensitivity decreased to 30% in inactive forms. It was demonstrated that ELISA was positive in cases with negative microscopy genitourinary tuberculosis. ELISA could be used as a supporting test in the laboratory diagnosis of active extrapulmonary tuberculosis in adults, disregarding the site involved.  相似文献   

14.
C. Lee  G.J. Nie  H.S. Joo  H. Momont   《Theriogenology》1993,40(6):1117-1126
An enzyme-linked immunosorbent assay (ELISA) was developed and evaluated to detect equine antisperm antibodies (ASA) in horse serum. Six maiden mares between 12 and 18 mo of age were immunized with stallion sperm cells (SC group, N=2), seminal plasma (SP group, N=2), or phosphate-buffered saline (PBS) as a control (C group, N=2). Horses received a second injection of the same antigen 2 wk after the first. Blood was collected weekly for 10 wk after initial immunization and again at Week 15. Serum ASA levels (IgG and IgA) were measured by ELISA using two assay systems, one containing stallion SC as the plate antigen and another containing SP.

In horses immunized with SC, peak IgG levels were detected by ELISA during Wk 2 and 3 after first injection using either plate antigen. The antibody levels persisted through Week 5 and then slowly declined until Week 15. Horses immunized with SP had IgG levels that did not differ from control horses using either ELISA plate antigen. The only significant elevation in serum IgA ASA occured during Week 5 after initial immunization and only in mares immunized with SC as detected by ELISA using SC as the plate antigen. Attachment of ASA to stallion spermatozoa was confirmed by an indirect immunofluorescence assay.  相似文献   


15.
16.
A dot-ELISA procedure was developed to detect antibodies against Encephalitozoon cuniculi. Sera from 84 rabbits, 22 dogs, 18 squirrel monkeys and 200 mice were tested by dot-ELISA and most also were tested by immunofluorescence. Comparison of the two tests showed that there was excellent agreement of the results (Kappa values greater than or equal to 0.74) in all four species. Dot-ELISA is a simple, quantitative, rapid alternative to immunofluorescence when large numbers of serum samples must be evaluated.  相似文献   

17.
An antigen-capture enzyme-linked immunosorbent assay (ELISA) was developed to detect and measure isometamidium chloride in the plasma of Oncorhynchus tshawytscha and O. mykiss. Isometamidium-ovalbumin conjugate and anti-isometamidium antibodies were used to coat polystyrene plates. The peroxidase saturation technique was used to optimize the coating antigen concentration; it demonstrated low affinity of the isometamidium-ovalbumin conjugate but high affinity of the anti-isometamidium antibodies for polystyrene surface sites. The optimal conditions of antiisometamidium antibodies to coat plates was at pH 7.3 and a 1:1000 dilution (0.0012 mg ml(-1) protein). The ELISA was sensitive as it detected 0.0006 mg ml(-1) of isometamidium in fish plasma. Isometamidium diluted with saline could not be detected at concentrations less than 0.05 mg ml(-1). The results indicate that this ELISA is much more sensitive when isometamidium is bound to plasma than unbound isometamidium in saline.  相似文献   

18.
An enzyme-linked immunosorbent assay (ELISA) was developed for the detection and identification of Renibacterium salmoninarum. The immune γ-globulin used in the assay was absorbed with two species of cross-reacting bacteria to make a specific test system. R. salmoninarum could be detected in clinically-diseased fish within 30 minutes of preparing a kidney sample, and thus because of its ease of use, the ELISA could be employed as a rapid field test for bacterial kidney disease (BKD), although isolation of R. salmoninarum was more sensitive than the ELISA for detecting individual carrier fish.  相似文献   

19.
A double-antibody sandwich, enzyme-linked immunosorbent assay has been developed for phytochrome in Avena sativa L. cv. Saladin. An immunoglobulin fraction of rabbit antiserum raised to 118 kdalton phytochrome was used with alkaline phosphatase as the enzyme label. The assay detected as little as 0.2 ng phytochrome in extracts of dark-grown plant material. No evidence for specific or non-specific measurement of proteins other than phytochrome was found. The assay detected phytochrome in extracts of Avena grown in the light. Dilution curves for light-grown phytochrome extracts had a reduced slope and saturated at a lower level of enzyme activity than those for dark extracts. These differences were not caused by an inhibitor in extracts from light-grown plants. Phytochromes from dark- and light-grown plants may be immunologically different.  相似文献   

20.
Naegleria fowleri, a free-living amoeba, is the causative agent of primary amoebic meningoencephalitis, a fatal human disease of the central nervous system often contracted after swimming in fresh water. Identifying sites contaminated by N. fowleri is important in order to prevent the disease. An Enzyme-Linked ImmunoSorbent Assay (ELISA) has been developed for the specific identification of N. fawleri in primary cultures of environmental water samples. Of 939 samples isolated from artificially heated river water and screened by ELISA, 283 were positive. These results were subsequently confirmed by isoelectric focusing, the established reference method. A sensitivity of 97.4% and a specificity of 97% were obtained. These results indicate that this ELISA method is reliable and can be considered as a powerful tool for the detection of N. fowleri in environmental water samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号