首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.

Background

The purpose of this study was to prospectively evaluate the efficacy and safety of remote magnetic navigation (RMN) in comparison with manual catheter navigation (MCN) in performing ventricular tachycardia ablation.

Methods

An electronic search was performed using PubMed (1948–2013) and EMBASE (1974–2013) studies comparing RMN with MCN which were published prior to 31 December 2013. Outcomes of interest were as follows: acute success, recurrence rate, complications, total procedure and fluoroscopic times. Standard mean difference (SMD) and its 95 % confidence interval (CI) were used for continuous outcomes; odds ratios (OR) were reported for dichotomous variables.

Results

Four non-randomised studies, including a total of 328 patients, were identified. RMN was deployed in 191 patients. Acute success and long-term freedom from arrhythmias were not significantly different between the RMN and control groups (OR 1.845, 95 % CI 0.731–4.659, p = 0.195 and OR 0.676, 95 % CI 0.383–1.194, p = 0.177, respectively). RMN was associated with less peri-procedural complications (OR 0.279, 95 % CI 0.092–0.843, p = 0.024). Shorter procedural and fluoroscopy times were achieved (95 % CI -0.487 to -0.035, p = 0.024 and 95 % CI -1.467 to -0.984, p<0.001, respectively).

Conclusion

The acute and long-term success rates for VT ablation are equal between RMN and MCN, whereas the RMN-guided procedure can be performed with a lower complication rate and less procedural and fluoroscopic times. More prospective randomised trials will be needed to better evaluate the superior role of RMN for catheter ablation of ventricular tachycardia.  相似文献   

2.
Contact force (CF) is one of the major determinants for sufficient lesion formation. CF-guided procedures are associated with enhanced lesion formation and procedural success. We report our initial experience in epicardial ventricular tachycardia (VT) ablation with a force-sensing catheter using a new approach with an angioplasty balloon. Two patients with arrhythmogenic right ventricular cardiomyopathy who underwent prior unsuccessful endocardial ablation were treated with epicardial VT ablation. CF data were used to titrate force, power and ablation time.  相似文献   

3.
Monomorphic ventricular tachycardia (VT) and symptomatic monomorphic PVCs originating from the region of the right and left outflow tracts are increasingly treated by radiofrequency (RF) catheter ablation. Technical difficulties in catheter manipulation to access these outflow tract areas, very accurate mapping and reliable catheter stability are key issues for a successful treatment in this vulnerable region. VT ablation from the aortic sinus cusp (ASC) in particular carries a significant risk of perforation, of creating left coronary artery injury and of damage to the aorta and the aortic valve. This case series describes RF ablation of VT originating in the outflow region using the remote magnetic navigation system (MNS). Potential advantages of the MNS are catheter flexibility, steering accuracy and reproducibility to navigate to a desired location with a low probability of perforating the myocardium. This report supports the idea of using advanced MNS technology during RF ablation in regions which are difficult to reach and thin walled, such as parts of the outflow tract and the ASC. (Neth Heart J 2009;17:245–9.)  相似文献   

4.

Background

The aim of the study was to compare in our center the effect of different ablation techniques on intermediate term freedom from atrial fibrillation (AF) or atrial tachycardia (AT) in patients affected by refractory AF.

Methods and Results

We retrospectively selected 94 patients who underwent AF ablation in our electrophysiological laboratory from June 2007 to December 2009. 29 patients underwent manual circumferential pulmonary vein isolation (mCPVI), 35 underwent remote magnetic navigation assisted CPVI (rmtCPVI) and 30 cryoballoon CPVI (cCPVI). Antiarrhythmic drugs were systematically stopped 2 months after the procedure (end of the "blanking period").At a mean follow-up of 12,64 ± 6,41 months (range 2-31), the success rate for mCPVI group was 65.5% (19 patients), 66.7 % (20 patients) for the rmtCPVI group and 65.7 % (23 patients) for the cCPVI group (p = 0.625). Procedural and fluoroscopy times were significantly reduced in the cCPVI group (both p < 0.001). Univariate Cox regression showed that no clinical variables were independently associated with recurrence.

Conclusions

In our center''s experience cCPVI and rmtCPVI have been demonstrated to be as effective as mCPVI. cCPVI seemed to be associated with lower procedural and fluoroscopy times.  相似文献   

5.
A 59-year-old female with structurally normal heart was admitted to our hospital for treatment of highly symptomatic, drug refractory atrial premature beats (APB). ECG revealed atrial parasystolic trigeminy. The arrhythmogenic focus was mapped and ablated using magnetic remote navigation and 3D electroanatomical mapping system. To our knowledge, this is the first report on successful ablation of frequent APBs in the non-coronary aortic cusp.  相似文献   

6.
7.
Fascicular ventricular tachycardia (VT) is an idiopathic VT with right bundle branch block morphology and left-axis deviation occuring predominantly in young males. Fascicular tachycardia has been classified into three subtypes namely, left posterior fascicular VT, left anterior fascicular VT and upper septal fascicular VT. The mechanism of this tachycardia is believed to be localized reentry close to the fascicle of the left bundle branch. The reentrant circuit is composed of a verapamil sensitive zone, activated antegradely during tachycardia and the fast conduction Purkinje fibers activated retrogradely during tachycardia recorded as the pre Purkinje and the Purkinje potentials respectively. Catheter ablation is the preferred choice of therapy in patients with fascicular VT. Ablation is carried out during tachycardia, using conventional mapping techniques in majority of the patients, while three dimensional mapping and sinus rhythm ablation is reserved for patients with nonmappable tachycardia.  相似文献   

8.
IntroductionEpicardial exit sites of ventricular tachycardia (VT) are frequently encountered during VT ablation requiring an epicardial ablation approach for successful elimination of VT. We sought to assess the utility of repolarization markers in identifying individuals requiring an epicardial ablation approach in addition to an endocardial approach.Methods32 patients who underwent successful ablation for scar mediated VT were included in the study. Fourteen patients who required a combined endocardial and epicardial VT ablation were defined as epicardial VT group (Epi) whereas 18 patients who were successfully ablated from the endocardium alone constituted the endocardial VT group (Endo). Repolarization markers during sinus rhythm were compared between the two groups.ResultsA higher QTc max and QTc dispersion were seen in the Epi group compared to Endo group (479 ± 34 vs 449 ± 20, p = 0.008 and 63 ± 13 vs 38 ± 8, p = 0.001, respectively). Ts-p and Ts-p/Tp-e were higher in the Epi group (166 ± 23 vs 143 ± 23, p = 0.008 and 1.55 ± 0.26 vs 1.3 ± 0.21, p < 0.005). On multivariate regression, QTc dispersion was an independent predictor of the need for an epicardial approach to ablation. A QTc dispersion more than 51.5 msec identified individuals requiring a combined epicardial and endocardial approach to ablation with a sensitivity of 92.9% and a specificity of 100%.ConclusionsPatients requiring an epicardial ablation have a higher QTc dispersion. A value greater than 51.5 msec reliably differentiates between the two groups with high sensitivity and specificity.  相似文献   

9.
Recent reports have described the incidence of atrioesophageal fistulas (AEF), often resulting in death, from radiofrequency (RF) catheter ablation of atrial fibrillation (AF).1 Cases of esophageal perforation without concomitant AEF have not been described as extensively.1 The precise mechanisms leading to esophageal injury after catheter ablation without involvement of the left atrium are not fully understood. The surgical approach to treat esophageal perforation is strongly recommended.2 However, a unified surgical treatment approach has not yet been established. We describe a case of successful surgical repair of an esophageal perforation after ablation using surgical repair in combination with an omental wrap.  相似文献   

10.
Space remote sensing for spatial vegetation characterization   总被引:1,自引:0,他引:1  
The study area, Madhav National Park (MP) represents northern tropical dry deciduous forest. The national park, due to its unique location (nearest to township), is under tremendous biotic pressure. In order to understand vegetation structure and dynamics, vegetation mapping at community level was considered important. Prolonged leafless period and background reflection due to open canopy poses challenge in interpretation of satellite data. The vegetation of Madhav National Park was mapped using Landsat TM data. The ground data collected from sample points were subjected to TWINSPAN analysis to cluster sample point data into six communities. The vegetation classification obtained by interpretation (visual and digital) of remote sensing data and TWINSPAN were compared to validate the vegetation classification at community level. The phytosociological data collected from sample points were analysed to characterize communities. The results indicate that structural variations in the communities modulate spectral signatures of vegetation and form basis to describe community structure subjectively and at spatial level.  相似文献   

11.
A 55 year old male presented with recurrent implantable cardioverter defibrillator (ICD) shocks due to polymorphic ventricular tachycardia (PMVT). He had undergone prior catheter ablation for VT three years ago. During the prior attempt he underwent voltage guided substrate ablation. With programmed ventricular extrastimulation (PVES), PMVT was repeatedly induced requiring DC shock. Intravenous procainamide was administered and PVES was repeated which induced sustained monomorphic ventricular tachycardia (MMVT). This VT had pseudo delta waves with maximum deflection index of 0.68, suggestive of epicardial origin. Activation mapping was performed epicardially. Presystolic potentials were recorded in mid anterolateral wall of left ventricular epicardial region. Radiofrequency (RF) ablation at this site terminated the VT. Post ablation there was no inducible tachycardia and patient is free of arrhythmias during 2 years of follow-up.  相似文献   

12.
A 77-year-old man underwent radiofrequency catheter ablation of incessant ventricular arrhythmias (VAs) originating from the right ventricular (RV) moderator band (MB). Activation mapping during the VAs exhibited a centrifugal pattern with the earliest activation site (EAS) on the RV septum. A local impedance (LI)-guided radiofrequency application targeting the EAS with a maximum power output of 50W successfully eliminated the VAs and resulted in an LI drop of up to 35 Ω. Late gadolinium enhancement magnetic resonance imaging (LGE-MRI) on the day after the ablation procedure demonstrated a confluent non-enhanced dark core on the RV septal portion of the MB. On the LGE-MRI two months after the procedure, the dark core region became contracted and instead the peripheral region surrounding the dark core exhibited a bright enhancement. The size of the dark core and peripheral enhanced regions on the LGE-MRI remained almost unchanged two months to two years after the procedure. He had no VA recurrences during a two-year follow-up period. Previous LGE-MRI studies reported that an ablated area within healthy ventricular myocardium exhibits a bright homogenous enhancement during the post-ablation chronic phase, while that within ventricular scar tissue exhibits a confluent non-enhanced dark core. This case suggested the presence of a dark core with a peripheral enhancement corresponding to the ablated area within the healthy myocardium of the RV-MB. LGE-MRI may be useful for accurately detecting RF ablation lesions on the RV-MB and visualizing the serial changes in the LGE-MRI characteristics from the post-ablation acute to chronic phases.  相似文献   

13.
Radiofrequency ablation (RFA) has been increasingly used in treating cancer for multitude of situations in various tissue types. To perform the therapy safely and reliably, the effect of critical parameters needs to be known beforehand. Temperature plays an important role in the outcome of the therapy and any uncertainties in temperature assessment can be lethal. This study presents the RFA case of fixed tip temperature where we’ve analysed the effect of electrical conductivity, thermal conductivity and blood perfusion rate of the tumour and surrounding normal tissue on the radiofrequency ablation. Ablation volume was chosen as the characteristic to be optimised and temperature control was achieved via PID controller. The effect of all 6 parameters each having 3 levels was quantified with minimum number of experiments harnessing the fractional factorial characteristic of Taguchi’s orthogonal arrays. It was observed that as the blood perfusion increases the ablation volume decreases. Increasing electrical conductivity of the tumour results in increase of ablation volume whereas increase in normal tissue conductivity tends to decrease the ablation volume and vice versa. Likewise, increasing thermal conductivity of the tumour results in enhanced ablation volume whereas an increase in thermal conductivity of the surrounding normal tissue has a debilitating effect on the ablation volume and vice versa. With increase in the size of the tumour (i.e., 2–3 cm) the effect of each parameter is not linear. The parameter effect varies with change in size of the tumour that is manifested by the different gradient observed in ablation volume. Most important is the relative insensitivity of ablation volume to blood perfusion rate for smaller tumour size (2 cm) that is also in accordance with the previous results presented in literature. These findings will provide initial insight for safe, reliable and improved treatment planning perceptively.  相似文献   

14.

Purpose

Although rare, children and young adults can suffer from significant cardiac arrhythmia, especially in the context of congenital malformations and after cardiac surgery.

Methods

A total of 62 patients (32 female, median age 20 years) underwent an invasive electrophysiology study between 2008–2011: half had normal cardiac anatomy, whereas the remaining patients had various types of congenital heart disease. All patients were treated using either conventional techniques (CVN) or remote magnetic navigation (RMN).

Results

Patients treated with the RMN system differed substantially from patients in the CVN group with respect to presence of congenital heart disease (67 % vs. 37 %), previous cardiac surgery (59 % vs. 20 %) or failed previous conventional ablation (22 % vs. 9 %), respectively. Although these more complex arrhythmias resulted in longer median procedure duration (180 vs. 130 min, p = 0.034), the median overall fluoroscopy exposure in the RMN group was significantly lower (4.1 vs. 5.2 min, p = 0.020). Clinical outcome was comparable in both groups without complications caused by the ablation.

Conclusions

Catheter ablation using remote magnetic navigation is safe and feasible in children and young adults and is especially valuable in patients with abnormal cardiac morphologies. RMN resulted in significantly lower radiation exposure compared with the conventional technique.  相似文献   

15.
Loggerhead sea turtle hatchlings (Caretta caretta) use regional magnetic fields as open-ocean navigational markers during trans-oceanic migrations. Little is known, however, about the ontogeny of this behaviour. As a first step towards investigating whether the magnetic environment in which hatchlings develop affects subsequent magnetic orientation behaviour, eggs deposited by nesting female loggerheads were permitted to develop in situ either in the natural ambient magnetic field or in a magnetic field distorted by magnets placed around the nest. In orientation experiments, hatchlings that developed in the normal ambient field oriented approximately south when exposed to a field that exists near the northern coast of Portugal, a direction consistent with their migratory route in the northeastern Atlantic. By contrast, hatchlings that developed in a distorted magnetic field had orientation indistinguishable from random when tested in the same north Portugal field. No differences existed between the two groups in orientation assays involving responses to orbital movements of waves or sea-finding, neither of which involves magnetic field perception. These findings, to our knowledge, demonstrate for the first time that the magnetic environment present during early development can influence the magnetic orientation behaviour of a neonatal migratory animal.  相似文献   

16.
17.
BackgroundThere are limited data describing the experience of radiofrequency (RF) vs. cryoballoon (CB) ablation for atrial fibrillation (AF) among elderly patients in the United States.MethodsWe conducted a retrospective analysis of patients ≥75 years of age undergoing index RF vs. CB ablation between January 2014 and May 2020 at our center. The choice of ablation technique was left to the operator's discretion. Major complications and efficacy, defined as freedom from any atrial tachyarrhythmia (ATA) lasting ≥30 s after one year of follow-up, were assessed in patients with index RF vs. CB ablation.ResultsIn our cohort of 186 patients, the median age was 78 (76–81) years, 54.8% were men, and 39.2% had persistent AF. The median CHA2DS2-VASc score was 4 (3–4), while the median duration of AF was 3 (1–7) years. The majority (n = 112, 60.2%) underwent RF ablation. The median procedure time was significantly lower in CB group (197 vs 226.5 min, p=<0.01). The incidence of complications was similar in the two sub-groups (RF: 1.8% vs. CB: 2.7%, p = 0.67). Similarly, arrhythmia-free survival rate on antiarrhythmic drugs at 1-year follow-up remained statistically comparable (63.4% vs. 68.9%, p = 0.33) between patients receiving RF vs. CB ablation.ConclusionThe safety and efficacy of RF vs. CB ablation for AF remained comparable in our cohort of patients older than 75 years. CB ablation was associated with a shorter procedure time.  相似文献   

18.
19.
Due to their adjuvant effect and their ability to chaperone tumor-associated peptides, heat shock proteins constitute a potent alarm signal for the immune system and can lead to activation of anti-tumor T-cell immunity. Radiofrequency ablation has been reported to induce heat shock protein expression especially that of heat shock protein 70 in sublethally damaged tumor cells. In this study, we evaluated the release of heat shock protein 70 into the serum of cancer-bearing patients directly after radiofrequency ablation. Sera of 22 patients undergoing radiofrequency ablation for the treatment of primary and secondary malignancies of the liver, kidney, and lung, as well as control sera of 20 patients undergoing diagnostic liver biopsy were analyzed using a manufactured heat shock protein 70 ELISA. A significant increase in serum levels of heat shock protein 70 was detectable in the patient cohort 1 day after radiofrequency ablation. More than a twofold increase was observed in nine out of 22 patients, which tended to correlate with favorable clinical outcome. No patient of the control group revealed a comparable increase. Radiofrequency ablation can lead to a release of heat shock protein 70 into the serum, which is transiently detectable 1 day after treatment. Elevated heat shock protein 70 serum levels may constitute a biomarker for favorable clinical outcome.  相似文献   

20.
IntroductionActivation mapping guided catheter ablation (CA) of ventricular arrhythmias (VAs) is limited in some cases when it is only relied on bipolar electrogram (EGM). We hypothesized that activation mapping with use of combined bipolar and unipolar EGM facilitates to identify the focal origin of VAs and results in reduction of recurrence rate of CA of VAs.MethodsWe analyzed the data of patients undergoing repeat ablations for idiopathic out-flow tract VAs. The EGM of the 1 st and 2 nd ablations were compared for earliest local activation time (LAT), presence of discrete potentials, and polarity reversal, unipolar potential morphology (QS or non-QS), potential amplitude and activation slope.ResultsThirty-seven patients were included. The Local activation time was significantly earlier in the 2nd ablation as compared to the 1st procedure (36.90 msec vs 31.85 msec, P < 0.01). The incidence of discrete potentials and polarity reversal were similar in both procedures (51% vs 57%, P = 0.8 and 62% in both the occasions, respectively). The unipolar voltage was similar in both occasions (6.94 mV vs 7.22 mV in repeat ablations, P = 0.7). The recurrence rate (5.7%) was significantly lower with routine use of combined unipolar and bipolar EGMs, as compared to the use of bipolar EGM alone (16.7%)ConclusionsUse of both bipolar and unipolar electrograms helps in better delineation of the sites of earliest activation for effective ablation of VAs. Use of unipolar electrograms in addition to bipolar electrograms is associated with lower long term recurrence rate.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号