首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
In multiple fields of study, access to the circulatory system in laboratory studies is necessary. Pharmacological studies in rats using chronically implanted catheters permit a researcher to effectively and humanely administer substances, perform repeated blood sampling and assists in conscious direct measurements of blood pressure and heart rate. Once the catheter is implanted long-term sampling is possible. Patency and catheter life depends on multiple factors including the lock solution used, flushing regimen and catheter material. This video will demonstrate the methodology of femoral artery and venous catheterization of the rat. In addition the video will demonstrate the use of the femoral venous and arterial catheters for blood sampling, drug administration and use of the arterial catheter in taking measurements of blood pressure and heart rate in a conscious freely-moving rat. A tether and harness attached to a swivel system will allow the animal to be housed and have samples taken by the researcher with minimal disruption to the animal. To maintain patency of the catheter, careful daily maintenance of the catheter is required using lock solution (100 U/ml heparinized saline), machine-ground blunt tip syringe needles and the use of syringe filters to minimize potential contamination. With careful aseptic surgical techniques, proper catheter materials and careful catheter maintenance techniques, it is possible to sustain patent catheters and healthy animals for long periods of time (several weeks).  相似文献   

2.
The rates of glucose production and utilization can be estimated by a primed-constant infusion technique using separate catheters for the infusion of radiolabelled glucose and periodic blood withdrawal. In rats, a carotid artery catheter is most often combined with a jugular or femoral venous catheter in such studies. We presently describe a method which utilizes a single jugular catheter for both infusion and sampling in the awake rat. This method is directly compared with simultaneous carotid artery sampling during both the dynamic steady state and a nonsteady state induced by a constant infusion of insulin. Our results demonstrate the validity of a single vein design for the analysis of glucose kinetics in either state. Rapid sampling and complete flushing prevent disruption of infusate equilibrium and sample contamination respectively. This single catheter method requires less technical skill for placement, reduces surgical intervention and enhances the comfort of the awake rat.  相似文献   

3.
In order to investigate new approaches in diagnosis, prevention and treatment of infectious complicating chemotherapy-induced granulocytopenia, we developed and prospectively evaluated a method of chronic central venous catheterization for the induction, maintenance and support of persistent granulocytopenia in rabbits. The method entails a central venous silastic catheter with a subcutaneous tunnel and a heparin lock device for repeated non-traumatic sampling of blood and administration of medications. During the course of 10 months, 226 rabbits were studied. Mean duration of catheter placement was 27 days, 17 of which were spent in granulocytopenia. Two-way flow was sustained throughout the duration of placement in 205 rabbits (91%) and for 5,845 (95%) of a total 6,163 catheter-days. All but two catheters could be flushed throughout the duration of their placement. Postoperative infectious complications related to catheter insertion developed in less than 1% of the rabbits. This method of chronic catheterization safely provides long-term venous access for studies requiring frequent venous access, including the painless induction, maintenance, and support of chronic granulocytopenia in rabbits.  相似文献   

4.
Chronic venous access and repeated blood sampling for research purposes in large swine ideally should be possible without sedation, restraint or direct venipuncture of deep vessels. An operative technique of cranial vena cava catheterization and chronic catheter maintenance methods are described which were used successfully in the placement of 11 silicone rubber catheters in 10 animals. All were used for repeated blood sampling, as well as intraoperative infusion of medications and large fluid volumes. Long term patency was excellent with 10 catheters patent at the end of the study interval, up to 14 weeks after insertion. Serial blood sampling was accomplished easily without restraint. Catheter damage, infection or malfunction was rare. Proper maintenance and careful aseptic blood sampling render the cranial vena cava catheter a safe and reliable alternative to direct venipuncture in swine.  相似文献   

5.
A surgical model for catheterization at multiple sites has been developed for use in long-term metabolic studies. For blood sampling, catheters were inserted into the portal and hepatic veins and the common carotid artery. The hepatic vein catheter was inserted from the margin of a liver lobe and led through the venous system, until the tip was close to the bifurcation with the inferior vena cava. A new technique was developed to ensure correct placement of the hepatic vein catheter using the specific extraction of indocyanin-green over the liver during surgery. Gastrostomy was performed using a Pezzer catheter. Catheters in the artery and hepatic and portal veins were patent for blood withdrawal for up to 4 weeks, and thus allowed repeated metabolic studies. Studies were performed in conscious animals familiar with the experimental situation.  相似文献   

6.
BACKGROUND: Totally implantable venous access devices are widely used for infusion of chemotherapy or parenteral nutrition. Device associated complications include technical operative problems, infections, paravasal infusions and catheter or punction chamber dislocation. CASE PRESENTATION: We present the case of a 49-year-old patient with the rare complication of a intrapulmonal catheter dislocation of a totally implantable venous access system. Treosulfane for chemotherapy of metastatic breast cancer was infused via the catheter causing instant coughing and dyspnoea which lead to the diagnosis of catheter dislocation. The intrapulmonal part of the catheter was removed under thoracoscopic control without further complications. CONCLUSION: Intrapulmonal catheter dislocation is a rare complication of a totally implantable venous access device which can not be avoided by any prophylactic measures. Therefore, the infusion system should be tested before each use and each new symptom, even when not obviously related to the catheter should be carefully documented and evaluated by expert physicians to avoid severe catheter-associated complications.  相似文献   

7.
Ninety-day pregnant ewes were either laparotomized, ovaries left in situ or bilaterally ovariectomized, and a jugular venous catheter and an inferior vena cava catheter via the saphenous vein were installed. Seven days later, placenta slices were collected and incubated in vitro for 4 h. Secretions of progesterone, PGE, estradiol-17beta and pregnancy-specific protein B (PSPB) in vitro by placenta from ovariectomized ewes were increased (P < or = 0.05) by 2.7-, 3.6-, 2.2-, and 2.4-fold, respectively, when compared to placenta slices from intact 90-day pregnant ewes. Secretion of PGF2alpha in vitro was unchanged (P > or = 0.05). Ovariectomy decreased (P < or = 0.05) jugular venous progesterone for 78 h followed by a quadratic increase (P < or = 0.05), whereas progesterone remained unchanged (P > or = 0.05) in intact ewes over the 162-h sampling period. Ovariectomy increased (P < or = 0.05) PGE in inferior vena cava plasma over the last half of the 162-h sampling period, whereas concentration of PGF2alpha did not change (P > or = 0.05). Increases in PGE occurred before the increase in progesterone. Concentrations of PSPB in inferior vena cava plasma of ovariectomized pregnant ewes increased (P < or = 0.05) during the last half of the 162-h sampling period, but not in intact ewes (P > or = 0.05). PSPB increased before PGE and progesterone. Concentrations of estradiol-17beta in jugular venous plasma of ovariectomized pregnant ewes increased (P < or = 0.05) during the last half of the sampling period, but not in intact ewes (P > or = 0.05). Increases in estradiol-17beta occurred before increases in PSPB. It is concluded that these data support the hypothesis that estradiol-17beta may control placental secretion of PSPB; PSPB may regulate placental secretion of PGE; and PGE may regulate placental secretion of progesterone.  相似文献   

8.
The fiberoptic central venous flotation catheter has gained widespread clinical acceptance for continuous monitoring of mixed venous oxyhemoglobin saturation. There are obvious research applications to this device, especially in monitoring very low central venous saturations in response to hypoxic challenge and cardiopulmonary exercise testing. However, the accuracy of this device has not been established in such low saturation ranges in humans. This study examines the tracking characteristics of the Opticath (Oximetrix, Mountain View, CA) pulmonary arterial catheter in comparison to simultaneously drawn blood specimens in which oxyhemoglobin saturation was determined by direct spectrophotometric oximetry. The results show that the catheter follows saturation established by bench oximetry quite closely between 50 and 80%, the range most commonly encountered in the clinical setting. However, at saturations below this range, the catheter consistently underestimates direct spectrophotometry. Since accuracy is extremely important for research purposes, two equations that can be used to correct catheter readings for mixed venous saturations less than 50% are presented.  相似文献   

9.

Background

Bacillus organisms are common laboratory contaminants. The majority of Bacillus bacteraemias are transient and not clinically significant. Clinically significant infection due to Bacillus species is rare and mostly due to Bacillus cereus infections in immuno-compromised hosts.

Case presentation

We report a case of central venous catheter infection with Bacillus pumilus in an immunocompetent child with tufting enteropathy on long-term parenteral nutrition (PN). There were three episodes of central venous catheter infection with Bacillus pumilus in three months. Despite adequate and appropriate use of intravenous antibiotics, the infection failed to clear resulting in the need for removal of the catheter for complete cure.

Conclusion

Bacillus species can cause clinically significant central venous catheter infection, even in an immunocompetent host. Despite adequate antibiotic treatment, the central venous catheter may need removal for complete cure.  相似文献   

10.
A nonhuman primate model comprising adult male rhesus monkeys (Macaca mulatta) with chronically indwelling subcutaneous central venous access devices provides a unique opportunity to determine plasma pharmacokinetics of new drugs such as anticancer and anti- retroviral agents. The central venous access we use is a low-profile, single-septum, titanium port that is attached to a radiopaque, indwelling catheter; the catheter is implanted in an internal jugular vein. A common complication following placement of the venous access device was migration of the catheter tip. We therefore modified the standard procedure by cutting the silicone catheter and introducing the rigid connector to secure the catheter to the vessel at the insertion site (approximately 9 to 13 cm from the distal end of the catheter). Prior to the use of the connector, three of five catheters migrated within 4 weeks after placement. In contrast, all 13 internal jugular catheters with connectors have remained patent without migration of the catheter tip. Therefore, incorporation of the catheter connector appears to have eliminated the problem of catheter migration.  相似文献   

11.
Long-term venous access for leukapheresis, repeated blood sampling, and administration of drugs and fluids can be accomplished nonsurgically in Yucatan miniature swine. The catheter is placed under fluoroscopic guidance into the inferior vena cava using a needle and guidewire. This procedure has the advantage that it avoids a surgical incision, allows high flow rates, exists conveniently on the lower back, and can be replaced easily in the event of mechanical failure or thrombosis. Actuarial analysis of the duration of patency disclosed that of 41 catheters placed in 30 animals, the probability of function at 28, 42, and 54 days was 75%, 50%, and 25%, respectively. Eleven nonfunctioning catheters were replaced and nine of these continued to function until the completion of the experiment. No catheters were removed due to infection. Chronic catheterization of the inferior vena cava is a convenient method for long-term venous access in swine.  相似文献   

12.
Early detection of myocardial ischemia is of major importance in critical-care medicine. Changes of lactate or glucose levels in the cardial venous efflux may be useful parameters. We succeeded in integrating an ultrafiltration membrane in a cardiac catheter for continuous sampling. The ultrafiltrate was analyzed outside the body, resulting in a lag-time of about 24 min. Biosensors in a flow-injection analysis system were used for minute by minute sample analyses. The coronary sinus of pigs was catheterized to monitor the effects of 5, 15 or 45 min ischemia by coronary artery obstruction or myocardial stress by dobutamine infusion. A total of 27 h was monitored. The intravascular response time was 1.33+/-0.61 min (10-90%). Linear regression in vivo of blood and ultrafiltrate samples was 0.977 for lactate and 0.994 for glucose. Lactate levels rose 0.38+/-0.10 mM above baseline within 5 min after ischemia. Reperfusion was clearly marked by a promptly peaking lactate release (maximum 9.27 mM). Myocardial stress by dobutamine increased glucose but not lactate levels. Once, a wall effect was noted at the catheter tip. In vivo semi-continuous myocardial monitoring of absolute lactate and glucose concentrations was thus achieved by an ultrafiltration catheter. Ischemia and reperfusion can be detected very early by a lactate level rise. Further, development of the ultrafiltration catheter will be focused on the diagnostic potential of lactate monitoring for patients.  相似文献   

13.
A technique is described for intermittent collection of portal venous blood from guinea pigs through a catheter advanced from an ileal tributary of the cranio-mesenteric vein into the portal vein and for the collection of bile from a catheter in the gallbladder after ligature obstruction of the common bile duct.  相似文献   

14.
目的对一起中心静脉置管后菌血症暴发感染进行调查分析,探讨防治措施,为预防和控制医院感染提供参考依据。方法对肿瘤内科4例患者在2008年8月4日-8日期间因中心静脉置管后菌血症暴发流行进行调查分析。结果4例患者血培养、中心静脉导管尖端和治疗室台面等均分离出产酸克雷伯菌,且药物菌谱完全一致。结论此次产酸克雷伯菌引起的菌血症为局部暴发流行。部分人员无菌观念淡薄、无菌操作执行不严可能是引起此次感染的主要原因。提示中心静脉置管者,一旦出现不明原因的感染症状,应考虑中心静脉置管因素。  相似文献   

15.
Local generation of kinins in working skeletal muscle tissue in man   总被引:1,自引:0,他引:1  
The effect of standardized isometric forearm work on circulating and local kinin concentrations was investigated in 12 healthy volunteers using the forearm catheter technique. Radioimmunological kinin determination in arterial blood and in the venous effluent of forearm muscle tissue was performed using a modification of Shimamoto's technique of blood sampling and kinin extraction. Under basal conditions, there was no arterio-venous difference of kinins. Throughout the whole experiment, arterial--reflecting systemically circulating--kinins did not change. In muscle venous blood, immunoreactive kinins were not significantly elevated during work, whereas a marked increase was detected in the recovery period (5.0 +/- 0.6 vs. 10.2 +/- 2.0 pmol/l; p less than 0.01). The data demonstrate, that kinins are locally generated in calculated amounts (32.7 +/- 8.4 fmol/(100 g x min) that are known to be sufficient to induce local vasodilatory and metabolic effects at the site of muscle contraction, but below the threshold for systemic cardiovascular actions.  相似文献   

16.
We have developed and validated catheterization protocols in mice that allow for simultaneous infusion and sampling. A sampling catheter was inserted in the lateral vein of the tail, while the animals were infused either intravenously or intragastrically through a second catheter placed in the contralateral lateral vein or via an intragastric catheter, respectively. The applicability of these methods of infusion and blood sampling were validated by conducting urea kinetics utilizing stable isotopes. These non-surgical procedures are non-invasive, inexpensive, fast to perform and animals do not require a recovery period before their use.  相似文献   

17.
To identify an obscure site of excessive ACTH production, selective venous sampling was performed by Seldinger's method in a 32-year-old man. Differential diagnosis between an ectopic ACTH producing tumor and Nelson's syndrome was quite inconclusive in this patient in spite of extensive clinical and laboratory evaluations, including pituitary surgery. In this study, PRL was measured in every sample as a reliable marker for pituitary drainage. Significantly higher rations (2.6 to 5.3) of catheter to peripheral (C/P) concentration of PRL at sites closer to the pituitary indicated successful samplings of pituitary drainage. C/P ratios of ACTH correlated very closely (correlation coefficient = 0.906, p less than 0.01) with those of PRL at every sampling site. Thus, it was concluded that the site of excessive ACTH production in this patient was in the pituitary gland. The methods applied in this study appear to be useful in differentiating ectopic from eutopic production of other pituitary hormones as well.  相似文献   

18.
Reasons why venous tracer infusion with arterial sampling [(v-a) mode] has advantages compared to arterial infusion and venous sampling [(a-v) mode] for studies of blood lactate kinetics are presented. Arterial tracer infusion can result in biased tracer input due to streaming and unequal blood flow distribution. The procedure is impractical for human studies. Venous sampling from the jugular, or any other peripheral or great vein, provides a sample which may, or may not represent mixed venous systemic blood, which exists only in the pulmonary artery. Venous sampling will not represent cardiac lactate metabolism because the coronary arteries drain into the coronary sinus. Venous sampling, as well as pulmonary artery sampling, will also ignore lactate metabolism in the lungs which drain into the left atrium from bronchial and pulmonary circulations. Turnover rates calculated from either venous or arterial specific activities underestimate true tissue turnover. Correction for either measurement depends on good estimates of blood flows to lactate exchanging and non-exchanging tissue. Equilibration between lactate and pyruvate pools does not invalidate the use of tracers to measure lactate turnover. The (v-a) mode with venous infusion and arterial sampling has advantages for lactate tracer studies.  相似文献   

19.
We prospectively evaluated the use of peripherally inserted central venous catheters to provide ongoing venous access in general medical and surgical patients in a Department of Veterans Affairs medical center. Between 1985 and 1988 trained nurses successfully inserted 393 catheters in 460 suitable patients (an 85.4% success rate). Correct catheter tip placement in the superior vena cava was documented in 359 of the 393 (91.3%) catheter insertions, but an additional 30 catheters were in a position deemed adequate for the intended use. The mean duration of catheter use was 27.6 +/- 5.2 (1 standard deviation) days (median 20 days, range 1 to 370 days). A total of 65 patients left the hospital with catheters in place, with the mean length of catheter use at home being 36.2 +/- 6.0 days (range 2 to 266). In all, 79% of the catheters were in use until the successful completion of therapy or patient death; catheter-related complications led to premature catheter removal in the remaining 21%. Catheter-related complications included bland phlebitis (8.2%), occlusion (8.2%), local infection (3.6%), bacteremia or fungemia (2.1%), mechanical failure or rupture (2.6%), venous thrombosis (0.7%), and other (3.3%). One patient required vein excision for the management of suppurative phlebitis, but no deaths were attributed to catheter use. This study illustrates the use and safety of peripherally inserted central venous catheters to provide reliable vascular access over prolonged periods in an elderly veteran population. At our facility, percutaneous central venous catheters and surgically implanted (Hickman or Broviac) catheters are now reserved for use in patients in whom peripherally inserted catheters cannot be placed.  相似文献   

20.
目的:探讨肺静脉口弧形指数与心房颤动(房颤)导管消融术后复发的关系。方法:选取2008年2月至2011年3月在我院接受导管消融术的房颤患者120例,所有患者于术前3日内利用多排CT行左心房及肺静脉造影,并进行图像的三维重建。测量每条肺静脉前后径及上下径,并计算弧形指数(肺静脉前后径/肺静脉上下径)以描述肺静脉口形态。行射频消融治疗的房颤病人全部达消融终点,术后随访超过3个月,根据患者房性快速性心律失常(房颤、房扑或房速)的发生情况,将其分为治愈组和复发组,进行统计分析。结果:由弧形指数分析,四支肺静脉开口形态存在统计学差异(P0.05);房颤消融术后,53例病人复发。房颤消融术后复发患者的LIPV弧形指数与治愈者不同,差异有显著性(P0.05);两组患者的左上肺静脉(Left Superior Pulmonary Vein,LSPV),右上肺静脉(Right Superior Pulmonary Vein,RSPV),右肺下静脉(Right Inferior Pulmonary Vein,RIPV),的弧形指数比较差异不明显(P0.05)。结论:左下肺静脉形态的不一致性与房颤导管消融术复发有关。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号