首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A novel biosensor for glucose measurement using functional polymers was fabricated and tested. The biosensor utilizes the physical and chemical functions of hydrophobic polydimethyl siloxane (PDMS) and hydrophilic 2-methacryloyloxyethyl phosphorylcholine (MPC) copolymerized with dodecyl methacrylate (DMA). The glucose sensor was constructed by immobilizing glucose oxidase (GOD) onto a flexible hydrogen peroxide electrode (Pt working electrode and Ag/AgCl counter/reference electrode). The electrodes were fabricated using microelectromechanical systems (MEMS) techniques onto those functional polymers. The sensor showed novel functions of flexibility and it was stretchable so that the sensor could normally work when it was released after expanding to 120% longer than that of normal length. Also, basic characteristics of the sensor were evaluated. The output current of the hydrogen peroxide electrode was linearly related to the hydrogen peroxide concentration in a range of 0.20-2.50 mmol/l, with a correlation coefficient of 0.998. GOD was then immobilized onto the surface of the sensor using MPC polymer. In this case, the current output of the glucose sensor related to the glucose level over a range of 0.06-2.00 mmol/l, with a correlation coefficient of 0.997. The calibration range includes the reported concentration of tear glucose in normal human subject (0.14 mmol/l).  相似文献   

2.
The glucose sensor was constructed by immobilizing glucose oxidase (GOD) with glutaraldehyde solution onto the sensitive area of the transparent oxygen electrode. The oxygen electrode was fabricated by sealing KCl electrolyte solution including the Indium-Tin Oxide (ITO)-electrode with both metal-weldable film and gas-permeable membrane coated with Ag/AgCl electrode. The sensor behavior was evaluated using standard glucose solutions in a batch measurement system with a computer-controlled potentiostat at a reduction potential of -900 mV. The sensor device has flexible structure and good optical transparency (less than 0.6 abs) at the visible wavelength from 400 to 700 nm. The sensor was possible to be used for measuring glucose from 0.06 to 1.24 mmol/l (correlation coefficient: 0.999), including the reported concentration of tear glucose in normal (0.14 mmol/l), with good reproducibility.  相似文献   

3.
Amperometric glucose biosensors have been developed based on entrapment on platinum (Pt) electrode using cyclic voltammetry technique in glucose oxidase (GOD) and pyrrole containing p-toluenesulfonic acid (pTSA) or sodium p-toluenesulfonate (NapTS) as supporting electrolyte solutions. Both of electrolyte solutions were suitable media for the formation and deposition of polypyrrole-GOD (PPy-GOD) layers on Pt substrate. Pt/PPy-GOD electrodes brought about in different morphological properties as well as different electrochemical and biochemical response. The highest responses obtained in pTSA and NapTS electrolytes were observed at pH of 4.5 and 7.0 for Pt/PPy-GOD electrodes, respectively. While linearity was observed between 0.0–1.0 mM glucose substrate for both electrodes, I max value of Pt/PPy-GODNapTS electrode was approximately twice as high as that of Pt/PPy-GODpTSA electrode as 25.4 and 14.2 μA, respectively. Five commercial drinks were tested with enzyme electrodes and compared with results obtained spectropho-tometrically using glucose kit. Results revealed that Pt/PPy-GODNapTS electrode exhibited better biosensor response.  相似文献   

4.
Highly sensitive amperometric enzyme immunosensors for human immunoglobulin G (IgG) were prepared on the basis of electrogenerated polytyramine (PTy, tyramine = p-(2-aminoethyl)-phenol) modified electrodes. Properties of PTy films changed depending on electrolysis conditions. On the basis of the found properties of the films, an effective IgG sensor was prepared: a PTy film was formed first from an acid solution on a Pt electrode, and the surface was further covered with a PTy film from an alkaline methanol solution to give a PTy doubly coated electrode on which anti-IgG was then immobilized. This electrode provided a large surface area with little non-specific adsorption of proteins. By means of the competitive enzyme immunoassay technique using glucose oxidase (GOD) labeled IgG conjugates, IgG was determined in the concentration range of c. 10 pg/ml-1 mg/ml from the oxidation current of H2O2 generated by the enzyme (GOD) reaction using the above IgG sensor. Also, an anti-IgG immobilized electrode, prepared by using a Pt electrode singly covered with a PTy film from an alkaline methanol solution, acted as an effective IgG sensor with a detection limit for IgG of c. 100 pg/ml.  相似文献   

5.
Amperometric glucose biosensors have been developed based on entrapment on platinum (Pt) electrode using cyclic voltammetry technique in glucose oxidase (GOD) and pyrrole containing p-toluenesulfonic acid (pTSA) or sodium p-toluenesulfonate (NapTS) as supporting electrolyte solutions. Both of electrolyte solutions were suitable media for the formation and deposition of polypyrrole-GOD (PPy-GOD) layers on Pt substrate. Pt/PPy-GOD electrodes brought about in different morphological properties as well as different electrochemical and biochemical response. The highest responses obtained in pTSA and NapTS electrolytes were observed at pH of 4.5 and 7.0 for Pt/PPy-GOD electrodes, respectively. While linearity was observed between 0.0-1.0 mM glucose substrate for both electrodes, I(max) value of Pt/PPy-GOD(NapTS) electrode was approximately twice as high as that of Pt/PPy-GOD(pTSA) electrode as 25.4 and 14.2 microA, respectively. Five commercial drinks were tested with enzyme electrodes and compared with results obtained spectrophotometrically using glucose kit. Results revealed that Pt/PPy-GOD(NapTS) electrode exhibited better biosensor response.  相似文献   

6.
A unique enzyme electrode was designed using glucose oxidase immobilized on fine graphite powder. The graphite-enzyme is in a fluid state which enables recharging of the system when the enzyme activity decreases, therefore allowing the system to have a long lifetime in a diabetic patient. The sensor was tested using glucose concentration in the range of 20–300 mg d−1. The electrode construction includes a hydrophobic membrane and a platinum electrode for detection of hydrogen peroxide. The signal output is large with minimal noise when tested in buffer. The sensor has been performing at ambient temperature for 4 months when stored overnight at 4° C.  相似文献   

7.
The functioning of a 16 x 16 pixel pulse frequency modulation (PFM) image sensor for retinal prosthesis is verified through in vitro electrophysiological experiments using detached frog retinas. This image sensor is a prototype for demonstrating the application to in vitro electrophysiological experiments. Each pixel of the image sensor consists of a pulse generator (PFM photosensor), a stimulus circuit, and a stimulus electrode (Al bonding pad). The image sensor is fabricated using standard 0.6 microm CMOS technology. For in vitro electrophysiological experiments, a Pt/Au stacked electrode is formed on the Al bonding pad of each pixel and the entire sensor is fixed in epoxy resin. The PFM image sensor is confirmed experimentally to provide electrical stimulus to the retinal cells in a detached frog retina.  相似文献   

8.
A new two-point calibration method for the subcutaneous amperometric continuous glucose sensor is reported. The proposed method is based on direct measurement of the background current (I(o)) using a non-enzyme electrode. For in vivo test, three electrodes were implanted in rabbits. Two of the three were identical needle-type enzyme electrodes with perfluorinated polymer outer layers (Pt/enzyme layer/Kel-F/PTFE/Kel-F/Nafion) that were placed in subcutaneous tissue and in a vessel (ear artery), respectively. And one non-enzyme electrode with exactly the same membrane composition as those of other two was in the subcutaneous layer to measure the background current. Implantation in the subcutaneous layer generated many crevices on the protecting layers of the electrodes. The signals from enzyme electrodes were effectively corrected by the measured background current from the non-enzyme electrode. In addition, a telemetric monitoring system was developed and evaluated for in vivo continuous glucose monitoring in order to alleviate the problems of motion artifact.  相似文献   

9.
This paper reports on a multilayer membrane amperometric glucose sensor fabricated using planar techniques. It is characterized by good reproducibility and suitable for large-scale production. The glucose sensor has 82 electrode sets formed on a single glass substrate, each with a platinum working electrode (WE), a platinum counter electrode (CE) and an Ag/AgCl reference electrode (RE). The electrode sets are coated with a membrane consisting of five layers: gamma-aminopropyltriethoxysilane (gamma-APTES), Nafion, glucose oxidase (GOX), gamma-APTES and perfluorocarbon polymer (PFCP), in that order. Tests have shown that the sensor has acceptably low dispersion (relative standard deviation, R.S.D.=42.9%, n=82), a wide measurement range (1.11-111 mM) and measurement stability over a 27-day period. Measurements of the glucose concentration in a control human urine sample demonstrated that the sensor has very low dispersion (R.S.D.=2.49%, n=10).  相似文献   

10.
The direct electrochemistry of glucose oxidase (GOD) adsorbed on a CdS nanoparticles modified pyrolytic graphite electrode was investigated, where the enzyme demonstrated significantly enhanced electron-transfer reactivity. GOD adsorbed on CdS nanoparticles maintained its bioactivity and structure, and could electro-catalyze the reduction of dissolved oxygen, which resulted in a great increase of the reduction peak current. Upon the addition of glucose, the reduction peak current decreased, which could be used for glucose detection. Performance and characteristics of the fabricated glucose biosensor were assessed with respect to detection limit, sensitivity, storage stability and interference exclusion. The results showed that the fabricated biosensor was sensitive and stable in detecting glucose, indicating that CdS nanoparticle was a good candidate material for the immobilization of enzyme in glucose biosensor construction.  相似文献   

11.
A chitosan-glutaraldehyde crosslinked uricase was immobilized onto Prussian blue nanoparticles (PBNPs) absorbed onto carboxylated multiwalled carbon nanotube (c-MWCNT) and polyaniline (PANI) layer, electrochemically deposited on the surface of Au electrode. The nanohybrid-uricase electrode was characterized by scanning electron microscopic (SEM), Fourier transform infrared spectroscopy (FTIR) and cyclic voltammetry. An amperometric uric acid biosensor was fabricated using uricase/c-MWCNT/PBNPs/Au electrode as working electrode, Ag/AgCl as standard and Pt wire as auxiliary electrode connected through a potentiostat. The biosensor showed optimum response within 4 s at pH 7.5 and 40 °C, when operated at 0.4 V vs. Ag/AgCl. The linear working range for uric acid was 0.005-0.8 mM, with a detection limit of 5 μM. The sensor was evaluated with 96% recovery of added uric acid in sera and 4.6 and 5.4% within and between batch of coefficient of variation respectively and a good correlation (r = 0.99) with standard enzymic colorimetric method. This sensor measured uric acid in real serum samples. The sensor lost only 37% of its initial activity after its 400 uses over a period of 7 months, when stored at 4 °C.  相似文献   

12.
A mixture of commercial creatinine amidohydrolase (CA), creatine amidinohydrolase (CI), and sarcosine oxidase (SO) was coimmobilized covalently via N-ethyl-N′-(3-dimethylaminopropyl) carbodiimide (EDC) and N-hydroxy succinimide (NHS) chemistry onto carboxylated multiwalled carbon nanotube (c-MWCNT)/polyaniline (PANI) nanocomposite film electrodeposited over the surface of a platinum (Pt) electrode. A creatinine biosensor was fabricated using enzyme/c-MWCNT/PANI/Pt as working electrode, Ag/AgCl as reference electrode, and Pt wire as auxiliary electrode connected through potentiostat. The enzyme electrode was characterized by scanning electron microscopy (SEM), Fourier transform infrared (FTIR) spectroscopy, and electrochemical impedance spectroscopy (EIS). The biosensor detected creatinine levels as low as 0.1 μM, estimated at a signal-to-noise ratio of 3, within 5 s at pH 7.5 and 35 °C. The optimized biosensor showed a linear response range of 10 to 750 μM creatinine with sensitivity of 40 μA/mM/cm2. The fabricated biosensor was successfully employed for determination of creatinine in human serum. The biosensor showed only 15% loss in its initial response after 180 days when stored at 4 °C.  相似文献   

13.
A new glucose biosensor has been fabricated by immobilizing glucose oxidase into a sol-gel composite at the surface of a basal plane pyrolytic graphite (bppg) electrode modified with multiwall carbon nanotube. First, the bppg electrode is subjected to abrasive immobilization of carbon nanotubes by gently rubbing the electrode surface on a filter paper supporting the carbon nanotubes. Second, the electrode surface is covered with a thin film of a sol-gel composite containing encapsulated glucose oxidase. The carbon nanotubes offer excellent electrocatalytic activity toward reduction and oxidation of hydrogen peroxide liberated in the enzymatic reaction between glucose oxidase and glucose, enabling sensitive determination of glucose. The amperometric detection of glucose is carried out at 0.3 V (vs saturated calomel electrode) in 0.05 M phosphate buffer solution (pH 7.4) with linear response range of 0.2-20 mM glucose, sensitivity of 196 nA/mM, and detection limit of 50 microM (S/N=3). The response time of the electrode is < 5s when it is stored dried at 4 degrees C, the sensor showed almost no change in the analytical performance after operation for 3 weeks. The present carbon nanotube sol-gel biocomposite glucose oxidase sensor showed excellent properties for the sensitive determination of glucose with good reproducibility, remarkable stability, and rapid response and in comparison to bulk modified composite biosensors the amounts of enzyme and carbon nanotube needed for electrode fabrication are dramatically decreased.  相似文献   

14.
Although most of enzyme catalytic reactions are specific, the amperometric detection of the enzymatic reaction products is largely nonselective. How to improve the detection selectivity of the enzyme-based electrochemical biosensors has to be considered in the sensor fabrication procedures. Herein, a highly selective amperometric glucose biosensor based on the concept of diffusion layer gap electrode pair which we previously proposed was designed. In this biosensor, a gold tube coated with a conductive layer of glucose oxidase/Nafion/graphite was used to create an interference-free region in its diffusion layer by electrochemically oxidizing the interfering electroactive species at proper potentials. A Pt probe electrode was located in this diffusion layer of the tube electrode to selectively detect hydrogen peroxide generated from the enzyme catalytic oxidation of glucose in the presence of oxygen in the solution. In practical performance of the microdevice, parameters influencing the interference-removing efficiency, including the tip-tube opening distance, the tube electrode potential and the electrolyzing time had been investigated systematically. Results showed that glucose detection free from interferents could be achieved at the electrolyzing time of 30s, the tip-tube opening distance of 3mm and the tube electrode potential of 0.4V. The electrochemical response showed linear dependence on the concentration of glucose in the range of 1 x 10(-5) to 4 x 10(-3) M (the correlation coefficient: 0.9936, without interferents; 0.9995, with interferents). In addition, the effectiveness of this device was confirmed by numerical simulation using a model system of a solution containing interferents. The simulated results showed good agreement with the experimental data.  相似文献   

15.
A portable and cost-effective technique to measure the dimethyl ether (DME) concentrations has been developed. It is based on an electrochemical principle measuring the oxidation current of DME at an applied potential of +0.2V versus a Ag/AgCl reference electrode. Thick-film printing technique is used for the fabrication of this DME sensor, and platinum nanoparticles in the crystallite size of 5.5 nm are used for the modification of the working electrode surface. This modification enhances the sensor performance significantly leading to a higher sensitivity of the sensor comparing to bare platinum electrode. Evaluation and characterization of this sensor are carried out over the DME concentration range of 0-7% (v/v), and a linear relationship between sensor outputs and the DME concentrations with an average R(2) of 0.996 exists. The reproducibility of the sensor is also very good. This electrochemically based DME sensor fabricated by thick-film screen printing technique and using the platinum nanoparticles to enhance its performance will be valuable and practical for the estimation of the airway mucosal blood flow.  相似文献   

16.
A novel glucose biosensor was fabricated. The first layer of the biosensor was polythionine, which was formed by the electrochemical polymerisation of the thionine monomer on a glassy carbon electrode. The remaining layers were coated with chitosan-MWCNTs, GOx, and the chitosan-PTFE film in sequence. The MWCNTs embedded in FAD were like “conductive wires” connecting FAD with electrode, reduced the distance between them and were propitious to fast direct electron transfer. Combining with good electrical conductivity of PTH and MWCNTs, the current response was enlarged. The sensor was a parallel multi-component reaction system (PMRS) and excellent electrocatalytic performance for glucose could be obtained without a mediator. The glucose sensor had a working voltage of −0.42 V, an optimum working temperature of 25°C, an optimum working pH of 7.0, and the best percentage of polytetrafluoroethylene emulsion (PTFE) in the outer composite film was 2%. Under the optimised conditions, the biosensor displayed a high sensitivity of 2.80 µA mM−1 cm−2 and a low detection limit of 5 µM (S/N = 3), with a response time of less than 15 s and a linear range of 0.04 mM to 2.5 mM. Furthermore, the fabricated biosensor had a good selectivity, reproducibility, and long-term stability, indicating that the novel CTS+PTFE/GOx/MWCNTs/PTH composite is a promising material for immobilization of biomolecules and fabrication of third generation biosensors.  相似文献   

17.
A novel DNAzyme-functionalized Pt nanoparticles/carbon nanotubes (DNAzyme/Pt NPs/CNTs) bioconjugate was fabricated as trace tag for ultrasensitive sandwich DNA detection. The Pt NPs/CNTs were prepared via layer-by-layer (LBL) assembly of the Pt NPs and polyelectrolyte on the carboxylated CNTs, followed by the functionalization with the DNAzyme and reporter probe DNA through the platinum-sulfur bonding. The subsequent sandwich-type DNA specific reaction would confine numerous DNAzyme/Pt NPs/CNTs bioconjugate onto the gold electrode surface for amplifying the signal. In the presence of 3,3',5,5' tetramethylbenzidine (TMB) which could be oxidized by the DNAzyme, electrochemical signals could be generated by chronoamperometry via the interrogation of reduction electrochemical signal of oxidized TMB. The constructed DNA sensor exhibited a wide linear response to target DNA ranging from 1.0fM to 10pM with the detection limit down to 0.6fM and exhibited excellent selectivity against even a single base mismatch. In addition, this novel DNA sensor showed fairly good reproducibility, stability, and reusability.  相似文献   

18.
A miniature Clark-type oxygen electrode was fabricated by anisotropically etching silicon. A two-gold-electrode configuration was used and a double-layered gas-permeable membrane was formed directly on the electrolyte, poly(vinyl-4-ethylpyridinium bromide) in the sensitive area. These materials improved the electrode's stability in long-term storage and sterilization tolerance to a practical level. The 90% response time averaged 80 s and residual current 10%, with a good linear calibration curve. The oxygen electrode was also used to make an integrated sensor for the simultaneous determination of glucose and oxygen. The glucose sensor's response time was 50-110 s, with good linearity in glucose concentrations between 56 microM and 1.1 mM at 37 degrees C, pH 7.0.  相似文献   

19.
Li J  Lin X 《Biosensors & bioelectronics》2007,22(12):2898-2905
Novel Pt nanoclusters embedded polypyrrole nanowires (PPy-Pt) composite was electrosynthesized on a glassy carbon electrode, denoted as PPy-Pt/GCE. A glucose biosensor was further fabricated based on immobilization of glucose oxidase (GOD) in an electropolymerized non-conducting poly(o-aminophenol) (POAP) film that was deposited on the PPy-Pt/GCE. The morphologies of the PPy nanowires and PPy-Pt nanocomposite were characterized by field emission scanning electron microscope (FE-SEM). Effect of experimental conditions involving the cycle numbers for POAP deposition and Pt nanoclusters deposition, applied potential used in glucose determination, temperature and pH value of the detection solution were investigated for optimization. The biosensor exhibited an excellent current response to glucose over a wide linear range from 1.5 × 10−6 to 1.3 × 10−2 M (r = 0.9982) with a detection limit of 4.5 × 10−7 M (s/n = 3). Based on the combination of permselectivity of the POAP and the PPy films, the sensor had good anti-interference ability to ascorbic acid (AA), uric acid (UA) and acetaminophen. The apparent Michaelis–Menten constant (Km) and the maximum current density (Im) were estimated to be 23.9 mM and 378 μA/cm2, respectively. In addition, the biosensor had also good sensitivity, stability and reproducibility.  相似文献   

20.
A novel amperometric nonenzymatic glucose sensor based on Au-doped NiO nanobelts has been successfully fabricated and applied to nonenzymatic glucose detection. Its electrochemical behavior towards the oxidation of glucose was compared with NiO nanofibers and Au microparticles prepared with a similar procedure. The NiO-Au hybrid nanobelts modified electrode displays greatly enhanced electrocatalytic activity towards glucose oxidation, revealing a synergistic effect between the matrix NiO and the doped Au. The as-prepared NiO-Au nanobelts based glucose sensor displays significantly lower onset potential, lower detection limit, higher sensitivity, and wider linear range than that of pristine NiO nanofibers modified electrode. Moreover, Au nanoparticles distributed in NiO nanofibers enabled amperometric glucose detection with insignificant interference from ascorbic acid and uric acid. These results indicate that the NiO-Au hybrid nanobelt is a promising candidate in the development of highly sensitive and selective nonenzymatic glucose sensors.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号