首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Hollow fiber liquid-phase microextraction (HF-LPME) coupled with high-performance liquid chromatography was used to simultaneously determine three Aconitum alkaloids, including aconitine (AC), hypaconitine (HA) and mesaconitine (MA) in human urine sample. Analytes were extracted from 5 mL urine sample containing 1.0 mmol/L NaOH into 1-octanol membrane phase impregnated in the pores of hollow fiber wall, and then back extracted into acidified aqueous solution in the lumen of the hollow fiber. After extraction, 10 μL of the acceptor phase was analyzed directly by HPLC. In this method, some important extraction parameters, such as organic solvent, extraction time, stirring rate, pH of donor phase and acceptor phase, temperature, and the volume of acceptor phase were optimized. This method provided 98- to 288-fold enrichment factors within 60 min of extraction and good repeatability with RSDs of 0.99–7.22%. The calibration curves were linear over the ranges of 16.0–128.0 μg/L for AC, 11.0–88.0 μg/L for HA and 8.1–64.8 μg/L for MA in human urine sample, with correlation coefficients of 0.9949, 0.9969 and 0.9904, respectively. Limits of detection were from 0.7 to 1.5 μg/L, and recoveries from spiked urine sample varied from 84.4% to 106.2% for AC, 77.3% to 85.6% for HA and 90.1% to 100.8% for MA.  相似文献   

2.
The applicability of hollow fiber liquid phase microextraction (HF-LPME) for extraction and preconcentration of trace amounts of pioglitazone (PGL) as an anti-diabetic drug in biological fluids, prior to determination by high-performance liquid chromatography (HPLC), was evaluated. In this technique, the target drug was extracted into di-n-hexyl ether immobilized in the wall pores of a porous hollow fiber from 10 mL of the aqueous sample (source phase, SP) with pH 8.0, and then back extracted into the receiving phase (RP) with pH 2.2 located in the lumen of the hollow fiber. The extraction occurred due to a pH gradient between the two sides of the hollow fiber. After extracting for a prescribed time, 24 μL of the RP solution was taken back into the syringe and injected directly into a HPLC instrument for quantification. The Taguchi orthogonal array (OAD) experimental design with an OA16 (45) matrix was employed to optimize the HF-LPME conditions. Different factors affecting the HF-LPME efficiency such as the nature of organic solvent used to impregnate the membrane, pH of the SP and RP, stirring speed, extraction time and ionic strength were studied and optimized. Under the optimum conditions (di-n-hexyl ether as membrane impregnation solvent, pHs of the SP and RP equal to 8.0 and 2.2, respectively, extraction time of 30 min, stirring speed of 500 rpm and 10% (w/v) NaCl for adjusting the ionic strength), preconcentration factor of 180, linear dynamic range (LDR) of 2.5–250 μg L?1 with good correlation of determination (r2 > 0.998) and limit of detection (LOD) of 1.0 μg L?1 were obtained for the target drug. The percent relative intra-day and inter-day standard deviations (RSDs%) based on five replicate determinations were 4.7 and 15%, respectively. Once LPME was optimized, the performance of the proposed technique was evaluated for the determination of PGL in different types of biological fluids such as plasma and urine samples. The results showed that the proposed HF-LPME method could be successfully applied to determine trace amounts of PGL in biological samples.  相似文献   

3.
In this paper, three phase-hollow fiber-based liquid phase microextraction (HF-LPME) combined with a HPLC procedure using diode array (DAD) and fluorescence detection (FLD) has been developed for the determination of four widely used sulfonamides: sulfadiazine, sulfamerazine, sulfamethazine, sulfamethoxazole and their main metabolites, the corresponding N(4)-acetyl derivatives: N(4)-acetyl-sulfadiazine, N(4)-acetyl-sulfamerazine, N(4)-acetyl-sulfamethazine, N(4)-acetyl-sulfamethoxazole. A Q3/2 Accurel KM polypropylene hollow fiber supporting 1-octanol was used between a 2 M Na(2)SO(4) aqueous solution (pH 4) as a donor phase and aqueous solution (pH 12) as an acceptor phase. The procedure allows very low detection and quantitation limits of 0.3-33 ng L(-1) and 0.9-100 ng L(-1), respectively. The proposed method was applied to the determination of the analytes in environmental water samples (surface, tap and wastewater).  相似文献   

4.
In this study, electromembrane extraction (EME) combined with cyclodextrin (CD)‐modified capillary electrophoresis (CE) was applied for the extraction, separation, and quantification of propranolol (PRO) enantiomers from biological samples. The PRO enantiomers were extracted from aqueous donor solutions, through a supported liquid membrane (SLM) consisting of 2‐nitrophenyl octyl ether (NPOE) impregnated on the wall of the hollow fiber, and into a 20‐μL acidic aqueous acceptor solution into the lumen of hollow fiber. Important parameters affecting EME efficiency such as extraction voltage, extraction time, pH of the donor and acceptor solutions were optimized using a Box‐Behnken design (BBD). Then, under these optimized conditions, the acceptor solution was analyzed using an optimized CD‐modified CE. Several types of CD were evaluated and best results were obtained using a fused‐silica capillary with ammonium acetate (80 mM, pH 2.5) containing 8 mM hydroxypropyl‐β‐CD as a chiral selector, applied voltage of 18 kV, and temperature of 20°C. The relative recoveries were obtained in the range of 78–95%. Finally, the performance of the present method was evaluated for the extraction and determination of PRO enantiomers in real biological samples. Chirality 26:260–267, 2014. © 2014 Wiley Periodicals, Inc.  相似文献   

5.
A method based on liquid-liquid-liquid microextraction combined with corona discharge ion mobility spectrometry was developed for the analysis of amantadine in human urine and plasma samples. Amantadine was extracted from alkaline aqueous sample as donor phase through a thin phase of organic solvent (n-dodecane) filling the pores of the hollow fiber wall and then back extracted into the organic acceptor phase (methanol) located in the lumen of the hollow fiber. All variables affecting the extraction of analyte including acceptor organic solvent type, concentration of NaOH in donor phase, ionic strength of the sample and extraction time were studied. The linear range was 20-1000 and 5-250 ng/mL for plasma and urine, respectively (r(2)≥0.990). The limits of detection were calculated to be 7.2 and 1.6 ng/mL for plasma and urine, respectively. The relative standard deviation was lower than 8.2% for both urine and plasma samples. The enrichment factors were between 45 and 54. The method was successfully applied for the analysis of amantadine in urine and plasma samples.  相似文献   

6.
A method based on hollow fiber supported liquid membrane extraction coupled with a gas chromatograph equipped with flame ionization detector (GC-FID) was developed for the determination of six short-chain fatty acids including acetic acid, propionic acid, i-butyric acid, n-butyric acid, i-valeric acid and n-valeric acid in serum. Hollow fiber supported liquid membrane extraction was employed for preconcentration and clean-up of the samples. The fatty acids were extracted from the acidic donor (diluted serum) into a liquid membrane formed in the wall of the hollow fiber with 10% tri-n-octylphoshphine oxide (TOPO) in di-n-hexyl ether, and then extracted back into a basic acceptor solution filled in the lumen of the hollow fiber. After being acidified with HCl, the acceptor was directly analyzed by GC-FID. The acceptor concentration, donor pH, membrane liquid and extracting time were optimized giving an enrichment factor up to 155 times. The good linearity (r(2)>0.980), reasonable recovery (87.2-121%), and satisfactory intra-assay (8.2-11.5%) and inter-assay (6.1-11.6%) precision illustrated the good performance of the present method. Limits of detection (LOD) ranged from 0.04 to 0.24 microM and limits of quantification (LOQ) varied from 0.13 to 0.80 microM.  相似文献   

7.
Liquid phase microextraction by back extraction (LPME-BE) combined with high performance liquid chromatography (HPLC)-fluorescence detection was developed for the determination of tramadol in human plasma. Tramadol was extracted from 2 mL of basic sample solution (donor phase) with pH 11.5 through a micro liter-size organic solvent phase (100 microL n-octane) for 25 min and finally into a 3.5 microL acidic aqueous acceptor microdrop with pH 2.5 suspended in the organic phase from the tip of a HPLC microsyringe needle for 15 min with the stirring rate of 1250 rpm. After extraction for a period of time, the microdrop was taken back into the syringe and injected into HPLC. Effected the experimental parameters such as the nature of the extracting solvent and its volume, sample temperature, stirring rate, volume of the acceptor phase, pH and extraction time on LPME-BE efficiency was investigated. At the optimized condition, enrichment factor of 366 and detection limit (LOD) of 0.12 microg L(-1) were obtained. The calibration curve was linear (r=0.999) in the concentration range of 0.3-130 microg L(-1). Within-day relative standard deviation RSD (S/N=3) and between-day RSD were 3.16% and 6.29%, respectively. The method was successfully applied to determine the concentration of tramadol in the plasma and urine samples and satisfactory results were obtained.  相似文献   

8.
Non-dispersive reactive extraction of cephalosporin antibiotics has been studied using hollow fiber membrane modules. Extraction as well as stripping has been studied using a pH swing procedure. Cephalosporin was extracted from an aqueous solution of cephalosporin having a pH above the pKa2 value to an organic phase containing Aliquat-336 as the extractant and n-heptane as the diluent. The solute was stripped from the loaded organic phase to another aqueous phase of pH maintained well below the pKa2 value of the cephalosporin. The extraction cum stripping relies on pH dependance of the distribution coefficient of cephalosporin in aqueous phase. Reasonably high solute recovery and mass transfer rate have been achieved in the hollow fiber module. Mass transfer performance of a single module has been evaluated and experimentally observed low value of height of transfer unit (HTU) indicates good prospect of hollow fiber membrane for the extraction duty.  相似文献   

9.
Three phase liquid phase microextraction (three phase LPME) technique coupled with HPLC-UV has been applied as a sensitive and efficient sample preparation method to determine phenylacetic acid (PAA) as a biomarker of depressive disorders and phenylpropionic acid (PPA) in biological fluids. The compounds were extracted from 3.0 ml aqueous solution with the adjustment of pH at a fixed value in the range of 2.0-3.5 (donor solution) into an organic phase (1-hexanol) layered on the surface of the donor solution and finally back-extracted into 4.0 microl of the acceptor microdrop (pH 11.1) located at the end of the microsyringe needle. After a prescribed back-extraction time, the acceptor microdrop was withdrawn into the microsyringe and then directly injected into the HPLC system. In order to achieve maximum extraction efficiency, different parameters affecting the extraction conditions were optimized. At the optimum conditions (donor solution: 2.3M Na(2)SO(4), pH 2.0-3.5; organic membrane: 95 microl of 1-hexanol; acceptor solution: 4.0 microl of 0.1M NH(3)/NH(4)(+) with pH 11.1; donor solution temperature: 45-50 degrees C; extraction time: 20 min and back-extraction time: 12 min), up to 110-fold enrichment factor was obtained. The calibration curve for these analytes was linear in the range of 1-5000 microg/l with r(2)>0.998. The intraday and interday RSD% were below 6.5% and the limits of detection (LODs) for both analytes were 0.2 microg/l (based on S/N=3). The proposed technique is a low cost, simple and sensitive method with highly clean-up effect. Finally, this technique was successfully utilized for the detection of target analytes in human urine, serum and plasma.  相似文献   

10.
This paper describes the bioconversion of 2-methyl-1,3-propanediol to (R)-beta-hydoxyisobutyric acid (HIBA) by Acetobacter ALEI in a hollow fiber membrane bioreaction system arrangement that allows the integration of three liquid phases: the aqueous bioconversion phase, the organic phase consisting of a solution of trioctyl phosphine oxide (TOPO) in isooctane, and the third phase consisting of a basic stripping solution that allows reextraction of HIBA from the organic phase. A comparison of HIBA mass transfer experiments was carried out in the membrane reactor with two and three phases for different pH and TOPO concentrations. The use of the three-phase arrangement allows the extraction of high quantities of HIBA from the aqueous medium (higher than 85%) independently of the pH, whereas in the two-phase system the percentage of HIBA extracted from the aqueous medium was lower, 42% in the best case, and strongly influenced by the pH. The percentage of the extractive agent TOPO in the organic phase influenced on the mass transfer rate in both bi- and triphasic arrangements. By simply integrating the re-extraction phase in the system it was possible to increase the extraction yield by 2-fold, reduce the amount of TOPO by 4-fold, and operate at the more favorable pH 4. A bioconversion experiment was done in these conditions (pH = 4, TOPO = 5%) to confirm the advantages of including the third stripping solution. Fed-batch operation of the triphasic membrane reactor was maintained for more than 20 h, reaching an HIBA concentration in the stripping solution of 29 g L(-)(1).  相似文献   

11.
In the present work, a simple and high sensitive method based on hollow fiber liquid phase microextraction (HF-LPME) was developed followed by high performance liquid chromatography (HPLC) for determination of ultra-trace amounts of Se(IV) after derivatization in biological and natural water samples. Se(IV) was complexed with o-phenylenediamine to form piazselenol. The formed piazselenol was extracted into 20 μL of 1-octanol located in the lumen of a hollow fiber and the solution was injected into HPLC-UV for analysis. Using the Taguchi method, an orthogonal array design (OAD), OA16 (45) was employed to optimize the HF-LPME of piazselenol. The effect of five experimental factors (each factor at four levels) including the volume of the organic phase, extraction time, pH of the solution, stirring rate and ionic strength on the extraction efficiency of piazselenol was studied and optimized. The maximum extraction efficiency of piazselenol was obtained at 20 μL of 1-octanol as the extracting solvent, 30 min extraction time, pH 2, stirring rate of 500 rpm and 30% (w/v) NaCl. Under the optimum conditions, preconcentration factors up to 130 were achieved and the relative standard deviation (%RSD) of the method was <3.7% for different concentrations of Se(IV). The calibration curves were obtained in the ranges of 0.2–100 and 0.05–10 μg L?1 for the 11 and 50 mL of the sample volumes with reasonable linearity, respectively (r2 > 0.995). The limits of detection (LOD) were 0.1 and 0.02 μg L?1 for the 11 and 50 mL sample volumes, respectively (S/N = 3). Finally, the applicability of the proposed method was evaluated by the extraction and determination of Se(IV) in the plasma, urine and water samples.  相似文献   

12.
A new method, based on hollow fiber liquid-phase microextraction (HF-LPME) and gas chromatography–tandem mass spectrometry (GC–MSMS), was developed for determination of Δ9-tetrahydrocannabinol (THC), cannabidiol (CBD) and cannabinol (CBN) in samples of human hair. Since hair is a solid matrix, the samples were subjected to alkaline digestion using NaOH. The aqueous solutions obtained were extracted using a 6 cm polypropylene fiber (600 μm i.d., 200 μm wall thickness, 0.2 μm pore size) for each extraction. A 25−1 fractional factorial design for screening, and a central composite design for optimization of significant variables, was applied during development of the extraction method. The variables evaluated were the type of extraction solvent, pH, stirring speed, extraction time, and acceptor phase volume. The optimized conditions for the proposed extraction procedure were 10 mg of hair sample; 20 μL of butyl acetate; aqueous (pH 14) donor phase containing 6.8% NaCl; 600 rpm stirring speed; 20 min extraction time. A linear response was obtained in the ranges 1–500 pg mg−1 (CBD and CBN) and 20–500 pg mg−1 (THC), with regression coefficients >0.99. Precision, determined as the relative standard deviation, was 3.3–8.9% (intra-day) and 4.4–13.7% (inter-day). Absolute recoveries varied in the ranges 4.4–4.8% (CBD), 7.6–8.9% (THC) and 7.7–8.2% (CBN). Limits of detection (LOD, S/N = 3) and quantification (LOQ, S/N = 10) were 0.5–15 pg mg−1 and 1–20 pg mg−1, respectively. The method was successfully used to determine CBD, THC and CBN in hair samples from patients in a drug dependency rehabilitation center. Concentrations varied in the ranges 1–18 pg mg−1 (CBD), 20–232 pg mg−1 (THC) and 9–107 pg mg−1 (CBN), confirming the suitability of the method for monitoring studies.  相似文献   

13.
A simple method of hollow fiber-liquid phase microextraction (HF-LPME) combined with gas chromatography (GC) was developed for the analysis of four phenothiazine drugs (promethazine, promazine, chlorpromazine and trifluoperazine) in human urine samples. All variables affecting the extraction of target analytes including organic solvent type, stirring rate, extraction time, extraction temperature, pH of sample solution and ionic strength were carefully studied and optimized. Under the optimal conditions, the analytical performance of HF-LPME-GC-flame photometric detector (FPD) and HF-LPME-GC-flame ionization detector (FID) were evaluated and compared. The results showed that the HF-LPME-GC-FID was more sensitive than HF-LPME-GC-FPD for the determination of four target phenothiazine drugs, while the signal peak shape and resolution obtained by HF-LPME-GC-FPD was better than that obtained by HF-LPME-GC-FID. HF-LPME-GC-FPD/FID was successfully applied for the assay of the interested phenothiazine drugs in urine sample, and the excretion of the drugs was also investigated by monitoring the variation of the concentration of chlorpromazine in urine of a psychopath within 8 h after drug-taking. The proposed method provided an effective and fast way for the therapeutic drug monitoring (TDM) of phenothiazine.  相似文献   

14.
Ultrasound-assisted ionic liquid dispersive liquid-liquid microextraction (UA IL-DLLME) coupled with high-performance liquid chromatography (HPLC) has been developed for the determination of celastrol in human urine samples. In the microextraction procedure, ionic liquid (IL) was used as extraction solvent and dispersed into the aqueous sample solution as fine droplets by means of dispersive solvent and ultrasonication which promoted the analyte to migrate into IL phase more easily. Several important parameters affecting the extraction efficiency were studied and optimized, including the type and volume of extraction solvent and dispersive solvent, sample pH, ultrasonication time, cooling time, centrifugation time and salting-out effect. Under the optimized conditions, 110-fold enrichment factor was obtained and the limit of detection (LOD) was 1.6 μg/L at a signal-to-noise ratio of 3. The calibration curve was linear over the range of 10-1000 μg/L for celastrol in human urine sample, with a correlation coefficient of 0.9980. Intra- and inter-assay precision were 0.43% and 2.78%, respectively. The proposed method was successfully applied to the real human urine samples and good spiked recoveries in the range of 93.2-109.3% were obtained.  相似文献   

15.
A liquid-phase microextraction technique was developed using dispersive liquid-liquid microextraction based on solidification of floating organic drop combined with flame atomic absorption spectrometry, for the extraction and determination of trace amounts of nickel in water samples. Microextraction efficiency factors, such as the type and volume of extraction and dispersive solvents, pH, extraction time, the chelating agent amount, and ionic strength, were investigated and optimized. Under optimum conditions, the calibration graph was linear in the range of 4.23-250?μg?L(-1) with a detection limit of 1.27?μg?L(-1). The relative standard deviation for ten replicate measurements of 10 and 100?μg?L(-1) of nickel were 3.21% and 2.55%, respectively. The proposed method was assessed through the analysis of certified reference water or recovery experiments.  相似文献   

16.
Progesterone in saliva was monitored using a new method called magnetic particle-based immuno supported liquid membrane assay (m-ISLMA) in a sequential injection (SI) setup, allowing automatic sample cleanup, analyte enrichment, and detection in a single analysis unit. Progesterone (Ag) diffuses from a continuous flowing sample - the donor - into a supported organic liquid membrane (SLM), based on analyte partitioning (solubility) between the aqueous donor and the organic phase. The Ag is re-extracted from the SLM into a second stagnant aqueous acceptor, containing antibodies (Ab) immobilized on magnetic beads, held at the bottom of the acceptor by a magnet. Due to the formation of strong Ag-Ab-bead complexes and a large excess of Ab-beads, the Ag is accumulated and selectively enriched in the acceptor. The extracted progesterone was quantified by injecting into the acceptor a horseradish peroxidase (HRP) labeled analyte tracer, the substrate (luminol, H(2)O(2), and p-iodophenol), and finally detection of the generated chemiluminescence by a photomultiplier tube. After optimization of experimental parameters (e.g., sample flow rate, extraction time, type of organic solvent and antibody-bead concentration in the acceptor), a detection limit of 8.50+/-0.17 fgL(-1) and a dynamic range between 35 fgL(-1) and 10 pgL(-1) was reached. The progesterone level of saliva for three subjects (women in different period of ovarian cycle) was investigated, and the corresponding progesterone concentrations detected with m-ISLMA coincided well with the expected values.  相似文献   

17.
The determination of drug-protein binding and free drug concentration in plasma applying the equilibrium sampling through membrane (ESTM) technique has been studied using supported liquid membrane extraction in a single hollow fibre without any membrane carrier. In the extraction setup, the donor phase (plasma or buffer) was placed in the vial, into which was immersed the hollow fibre with the acceptor phase situated in the lumen. This proposed technique was applied to study the drug-protein binding of five local anaesthetics and two antidepressants as model substances, and the influence of the total drug concentration on the drug-protein binding was investigated. The brief theoretical background for determination of the drug-protein binding under equilibrium conditions is described. The developed method shows a new, improved and simple procedure for determination of free drug concentration in plasma and extent of drug-protein binding.  相似文献   

18.
In this article, hollow fiber renewal liquid membrane (HFRLM) technique was used for recovery of penicillin G from aqueous solution. The organic solution of 7 vol % di‐n‐octylamine (DOA) + 30 vol % iso‐octanol + kerosene was used as liquid membrane phase, and Na2CO3 aqueous solution was used as stripping phase. Experiments were performed as a function of carrier concentration in the organic phase, organic/aqueous volume ratio, pH, and initial penicillin G concentration in the feed phase, pH in the stripping phase, flow rates, etc. The results showed that the HFRLM process was stable and could carry out simultaneous extraction and concentration of penicillin G from aqueous solutions. As a carrier facilitated transport process, the addition of DOA in organic phase could greatly enhance the mass transfer rate; and there was a favorable organic/aqueous volume ratio of 1:20 to 1:30 for this system. The mass transfer flux and overall mass transfer coefficient increased with decreasing pH in the feed phase and increasing pH in the stripping phase, because of variation of the mass transfer driving force caused by pH gradient and distribution equilibrium. The flow rate of the shell side had significant influence on the mass transfer performance, whereas the effect of flow rate of lumen side on the mass transfer performance was slight because of the mass transfer intensification of renewal effect in the lumen side. The results indicated that the HFRLM process was a promising method for the recovery of penicillin G from aqueous solutions. © 2009 American Institute of Chemical Engineers Biotechnol. Prog., 2009  相似文献   

19.
In the present study, a novel quantitative method, namely magnetic nanoparticle-based solid-phase extraction (MSPE), was applied to extract vitamin B(12) from pharmaceutical formulations. The technique involves the use of Fe(3)O(4) nanoparticles modified by sodium dodecyl sulfate (SDS) as an efficient adsorbent for solid-phase extraction of vitamin B(12). Collection of magnetic nanoparticles (MNPs) from aqueous solution was simply achieved by applying external magnetic field. The analyte was desorbed from MNPs using alkali 1-propanol. The extracted analyte was analyzed by using flow injection inductively coupled plasma-optical emission spectrometry. Factors affecting the extraction efficiency were investigated and optimized. Under the optimum conditions, enhancement factor of 184, linear dynamic range of 2.5-500 μg L(-1) with correlation of determination (R(2) > 0.999), and limit of detection of 1.0 μg L(-1) were obtained for vitamin B(12). The percent relative standard deviation based on five-replicate determination was less than 6.2%. The method was successfully applied for extraction and determination of vitamin B(12) in different types of pharmaceutical samples such as multivitamin tablet, effervescent tablet, and injection sample. The results showed that the proposed method based on SDS-Fe(3)O(4) MSPE was a simple, accurate, and highly efficient approach for analysis of vitamin B(12).  相似文献   

20.
Recovery of penicillin by reactive extraction in centrifugal extractors   总被引:2,自引:0,他引:2  
Penicillin V and/or G were extracted from fermentation broth by Amberlite LA-2 in n-butylacetate at pH 5 in a laboratory centrifugal extractor, Type SA 01 of Westfalia, up to an overall phase throughput rate of 30 L/h, in a bench-scale four-stage extraction system, consisting of Type TA 1 of Westfalia, up to an overall phase throughput rate of 110 L/h, and in a pilot-plant three-stage extraction unit, consisting of Type TA 7 extractors of Westfalia, up to a phase throughput rate of 990 L/h with very high degrees of extraction (up to 99%). The reextraction from the ion-pair complex, which contained organic solvent, was performed by phosphate, borate, or carbonate buffer at pH 7.5-8.5 in all three extractor systems with degrees of extraction up to 98%, but at considerably lower overall phase throughput rates than those of the extraction, since no satisfactory phase separation is possible at higher throughput rates.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号