首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A specific method for the determination of erythromycin 2'-ethylsuccinate (EM-ES) in plasma is described. The method involves a liquid—liquid extraction procedure followed by the analysis of extracts using phase-system switching (PSS) continuous-flow fast atom bombardment (CF-FAB) liquid chromatography—mass spectrometry (LC—MS). In PSS EM-ES is enriched after analytical separation on a short trapping column, from which it is desorbed to the LC—MS interface. In this way, favourable mobile phases can be used for the LC separation and for the MS detection. Using the PSS approach a flow-rate reduction from 1.0 ml/min in the LC system to 15 μl/min going into the mass spectrometer was achieved without splitting. The determination limit for EM-ES was 0.1 μg/ml.  相似文献   

2.
A method for the qualitative and quantitative simultaneous analysis of dioxyanthraquinone, desacetyl-Bisacodyl, phenolphthalein and Oxyphenisatin in human urine using gas chromatography—mass spectrometry (GC—MS) has been developed. The compounds were extracted from urine at pH 7.5 with diethyl ether using Extrelut extraction columns, followed by evaporation and trimethylsilylation.The method used electron beam ionization GC—MS employing a computer-controlled multiple-ion detector (mass fragmentography). The recovery from urine for the various compounds was between 80% and 100%. The detection limit for these compounds was in the range 0.01–0.05 μg/ml of urine.The method proved to be suitable for measuring urine concentrations for at least four days after administration of a single oral low therapeutic dose of the laxatives to sixteen healthy volunteers.  相似文献   

3.
Methods for the determination of 3,4-dichloroaniline (3,4-DCA) and 3,5-dichloroaniline (3,5-DCA) as common markers of eight non-persistent pesticides in human urine are presented. 3,5-DCA is a marker for the exposure to the fungicides vinclozolin, procymidone, iprodione, and chlozolinate. Furthermore the herbicides diuron, linuron, neburon, and propanil are covered using their common marker 3,4-DCA. The urine samples were treated by basic hydrolysis to degrade all pesticides, metabolites, and their conjugates containing the intact moieties completely to the corresponding dichloroanilines. After addition of the internal standard 4-chloro-2-methylaniline, simultaneous steam distillation extraction (SDE) followed by liquid–liquid extraction (LLE) was carried out to produce, concentrate and purify the dichloroaniline moieties. Gas chromatography (GC) with mass spectrometric (MS) and tandem mass spectrometric (MS–MS) detection and also detection with an electron-capture detector (ECD) after derivatisation with heptafluorobutyric anhydride (HFBA) were employed for separation, detection, and identification. Limit of detection of the GC–MS–MS and the GC–ECD methods was 0.03 and 0.05 μg/l, respectively. Absolute recoveries obtained from a urine sample spiked with the internal standard, 3,5-, and 3,4-DCA, ranged from 93 to 103% with 9–18% coefficient of variation. The three detection techniques were compared concerning their performance, expenditure and suitability for their application in human biomonitoring studies. The described procedure has been successfully applied for the determination of 3,4- and 3,5-DCA in the urine of non-occupationally exposed volunteers. The 3,4-DCA levels in these urine samples ranged between 0.13 and 0.34 μg/g creatinine or 0.11 and 0.56 μg/l, while those for 3,5-DCA were between 0.39 and 3.33 μg/g creatinine or 0.17 and 1.17 μg/l.  相似文献   

4.
A GC method using a novel derivatization reagent, 2′,2′,2-trifluoroethyl chloroformate (TFECF), for the derivatization of primary and secondary aliphatic amines with the formation of carbamate esters is presented. The method is based on a derivatization procedure in a two-phase system, where the carbamate ester is formed. The method is applied to the determination of 1,6-hexamethylene diamine (HDA) in aqueous solutions and human urine, using capillary GC. Detection was performed using thermionic specific detection (TSD) and mass spectrometry (MS)—selective-ion monitoring (SIM) using electron-impact (EI) and chemical ionization (CI) with ammonia monitoring both positive (CI)+ and negative ions (CI). Quantitative measurements were made in the chemical ionization mode monitoring both positive and negative ions. Tetra-deuterium-labelled HDA (TDHDA; H2NC2H2(CH2)4C2H2NH2) was used as the internal standard for the GC—MS analysis. In CI+ the m/z 386 and the m/z 390 ions corresponding to the [M + 18]+ ions (M = molecular ion) of HDA—TFECF and TDHDA—TFECF were measured; in CI the m/z 267 and the m/z 271 ions corresponding to the [M — 101] ions. The overall recovery was found to be 97 ± 5% for a HDA concentration of 1000 μg/l in urine. The minimal detectable concentration in urine was found to be less than 20 μg/l using GC—TSD and 0.5 μg/l using GC—SIM. The overall precision for the work-up procedure and GC analysis was ca. 3% (n = 5) for 1000 μg/l HDA-spiked urine, and ca. 4% (n = 5) for 100 μg/l. The precision using GC—SIM for urine samples spiked to a concentration of 5 μg/l was found to be 6.3% (n = 10).  相似文献   

5.
A rapid and sensitive method for the assay of zonisamide in serum was developed using a solid-phase extraction technique followed by high-performance liquid chromatography. A 20-μl volume of human serum was first purified with a Bond-Elut cartridge column. Then, the methanol eluate was injected onto a reversed-phase HPLC column with a UV detector. The mobile phase was acetonitrile—methanol—distilled water (17:20:63, v/v) and the detection wavelength was 246 nm. The detection limit was 0.1 μg/ml in serum. The coefficients of variation were 4.2–5.6% and 5.1–9.1% for the within-day and between-day assays, respectively. This method can be used for clinical pharmacokinetic studies of zonisamide in serum even in infant patients with epilepsy.  相似文献   

6.
An automated gas chromatographic—mass spectrometric assay for theophylline is described. Theophylline is extracted from plasma or urine (50 μl) and transformed into an N-pentyl derivate. The internal standard used for quantitation is [1,3-15N, 2-13C]theophylline. The detection is performed by monitoring the molecular ions 250 for theophylline and 253 for the internal standard with a quadrupole mass specific detector HP 5790 A. The system has been fully automated: injection, calibration, assay, calculation. The method shows excellent analytical parameters: linearity between 2 and 40 μg/ml; day-to-day reproducibility 1.82% for a concentration of 15 μg/ml; repeatability 0.75% (15 μg/ml) and 0.33% (30 μg/ml). Accuracy is also excellent. Due to the use of an internal standard labelled with stable isotopes, the specificity and high analytical quality of the method make it useful as a reference method to compare with routine theophylline assays.  相似文献   

7.
A gas chromatographic technique for determining zopiclone based on a solid-phase extraction procedure with C18 cartridge for sample clean-up is presented. Quantification can be achieved with 1 ml of plasma. The method uses prazepam as internal standard. Zopiclone is separated on a 5% phenyl methyl silicone analytical column and detected with an electron-capture detector, which consequently allows a limit of quantitation of 2 μg/l. It is thus simple, rapid, sensitive and linear over the range 5–2000 μg/l.  相似文献   

8.
A simple and selective procedure for the determination of vinorelbine, a new semi-synthetic vinca alkaloid, is presented. The method is based on ion-exchange high-performance liquid chromatography on normal-phase silica with fluorescence detection, combined with liquid—liquid extraction using diethyl ether for sample clean-up. The absence of endogenous interferences and the excellent chromatographic behaviour of vinca alkaloids provides accurate results even at low concentrations. The limit of determination in plasma is 1.5 μg/l (500-μl sample). Reproducible recoveries in urine were obtained if 10–50 μl of sample were processed supplemented with 500 μl of blank plasma.  相似文献   

9.
Phencyclidine and monohydroxy metabolites were measured in human urine using gas chromatography—mass fragmentography with methane chemical ionization. Samples were extracted either untreated or following acid hydrolysis, derivatized with heptafluorobutyric anhydride, separated on a 3% SE-30 column and analyzed by mass fragmentography. The assay was sensitive to ca. 0.01 μg/ml for phencyclidine and ca. 0.05 μg/ml for the metabolites. Urine samples from five human subjects enrolled in a methadone maintenance program who had ingested phencyclidine were analyzed. The phencyclidine concentration ranged from 0.3 to 23.7 μg/ml. The concentrations of metabolites ranged from 0 to 1.8 μg/ml. A new monohydroxy metabolite was detected in the samples, but its structure was not fully elucidated. The specificity of the assay was examined.  相似文献   

10.
A method for the simultaneous measurement of dothiepin and two of its major metabolites, northiaden and dothiepin S-oxide in both plasma and whole blood is described. The method involves the use of gas chromatography—mass fragmentography. It is selective, sensitive (1 μg/l) and reproducible.It has been used to analyse both plasma and blood samples following single oral doses of 75 mg dothiepin in seven volunteers.  相似文献   

11.
A selective assay of olanzapine with liquid chromatography atmospheric pressure chemical ionization (LC–APCI–MS, positive ions) is described. The drug and internal standard (ethyl derivative of olanzapine) were isolated from serum using a solid-phase extraction procedure (C18 cartridges). The separation was performed on ODS column in acetonitrile–50 mM ammonium formate buffer, pH 3.0 (25:75). After analysis of mass spectra taken in full scan mode, a selected-ion monitoring detection (SIM) was applied with the following ions: m/z 313 and 256 for olanzapine and m/z 327 and 270 for the internal standard for quantitation. The limit of quantitation was 1 μg/l, the absolute recovery was above 80% at concentration level of 10 to 100 μg/l. The method tested linear in the range from 1 to 1000 μg/l and was applied for therapeutic monitoring of olanzapine in the serum of patients receiving (Zyprexa™) and in one case of olanzapine overdose. Olanzapine in frozen serum samples and in frozen extracts was stable over at least four weeks. The examinations of urine extracts from patients receiving olanzapine revealed peaks of postulated metabolites (glucuronide and N-desmethylolanzapine).  相似文献   

12.
A simple and highly sensitive method has been developed for the determination in plasma of ciprostene, 9β-methyl-6α-carbaprostaglandin I2, using gas chromatography—mass spectrometry following solid-phase extraction on an immobilized antibody column. The anti-ciprostene antibody obtained from rabbit serum was coupled to an agarose support matrix, and the immobilized antibody thus prepared was used as an extraction phase for sample clean-up. The extracted drug was treated with pentafluorobenzyl bromide followed by bis(trimethylsilyl)trifluoroacetamide. The derivative was quantitatively analysed by negative-ion chemical ionization gas chromatography—mass spectrometry. The lower limit of quantitation was 50 pg/ml when 1 ml of human plasma was used. The plasma concentration of ciprostene in a dog treated with ciprostene at 2.5 μg/kg was determined successfully by this method.  相似文献   

13.
A gas chromatographic—mass spectrometric method for the determination of cobalt in biological materials employing stable enriched 62Ni as an internal standard and using lithium bis(trifluoroethyl)dithiocarbamate as a chelating agent is described. The method involves the addition of a known amount (1 μg) of 62Ni to the sample, the formation of the chelate and the determination by selected-ion monitoring of the m/z ratio, which corresponds to . No appreciable memory effect was observed, and an acceptable dynamic range of 100 was found. There was good agreement between the cobalt concentration values determined by gas chromatography—mass spectrometry and electrothermal atomic absorption spectrometry. The present method has high sensitivity and can be used for the quantitation of cobalt at concentrations as low as 1 μg/l. The use of enriched 62Ni circumvents the problem caused by endogenous nickel and simultaneously provides data on the nickel concentration in the biological sample without any additional experimental effort.  相似文献   

14.
High-temperature headspace solid-phase microextraction (SPME) with simultaneous (“in situ”) derivatisation (acetylation or silylation) is a new sample preparation technique for the screening of illicit drugs in urine and for the confirmation analysis in serum by GC–MS. After extraction of urine with a small portion of an organic solvent mixture (e.g., 2 ml of hexane–ethyl acetate) at pH 9, the organic layer is separated and evaporated to dryness in a small headspace vial. A SPME-fiber (e.g., polyacrylate) doped with acetic anhydride–pyridine (for acetylation) is exposed to the vapour phase for 10 min at 200°C in a blockheater. The SPME fiber is then injected into the GC–MS for thermal desorption and analysis. After addition of perchloric acid and extraction with n-hexane to remove lipids, the serum can be analysed after adjusting to pH 9 as described for urine. Very clean extracts are obtained. The various drugs investigated could be detected and identified in urine by the total ion current technique at the following concentrations: amphetamines (200 μg/l), barbiturates (500 μg/l), benzodiazepines (100 μg/l), benzoylecgonine (150 μg/l), methadone (100 μg/l) and opiates (200 μg/l). In serum all drugs could be detected by the selected ion monitoring technique within their therapeutic range. As compared to liquid–liquid extraction only small amounts of organic solvent are needed and larger amounts of the pertinent analytes could be transferred to the GC column. In contrast to solid-phase extraction (SPE), the SPME-fiber is reusable several times (as there is no contamination by endogenous compounds). The method is time-saving and can be mechanised by the use of a dedicated autosampler.  相似文献   

15.
A method for the quantification of clindamycin in human serum and in human bone tissue samples applying high-performance liquid chromatography with atmospheric pressure chemical ionization–mass spectrometry (APCI–MS) is presented. Lincomycin is used as the internal standard. Serum samples are prepared only by protein precipitation with acetonitrile. Bone tissue samples have to be crushed and homogenized in extraction buffer prior to analysis. The chromatographic separation is achieved on an RP-18 stationary phase with 0.02% trifluoroacetic acid in water 60%/acetonitrile 40% v/v as mobile phase. The limits of quantification are 0.1 μg/ml for serum samples and 0.1 μg/g for bone tissue samples. The coefficients of variation for the assays are 4.48 and 8.41% at the limit of quantification for serum and bone tissue samples, respectively. Bone tissue samples as small as 50 mg can be used.  相似文献   

16.
The well-known beneficial health effects of Se have demanded the development of rapid and accurate methods for its analysis. A flow injection (FI) method with inductively coupled plasma mass spectrometry (ICP-MS) as a selenium-selective detector was optimized. Flow injection was carried out using a Knauer 1100 smartline inert series liquid chromatograph coupled with a Perkin Elmer DRC II ICP-mass spectrometer. For sample injection a Perkin Elmer electronic valve equipped with a 25 μL sample loop was employed. Before measurement, standards or samples were administered with 1 μg/L rhodium as internal standard for correction of changes in detector response according to changes in sample electrolyte concentration. The method characterization parameters are: LOD (3σ criterion): 26 ng/L, LOQ (10σ criterion): 86 ng/L, linearity: 0.05–>10 μg/L, r2=0.9999, serial or day-to-day precision at 2 μg/L: 4.48% or 5.6%. Accuracy was determined by (a) recovery experiments (CSF spiked with 2 μg/L Se); (b) comparison of FI-ICP-MS measurement with graphite furnace atomic absorption (GFAAS) measurements of 1:10 diluted serum samples; (c) Se determination in urine and serum control materials. Recovery (a) was 101.4%, measurement comparison with GFAAS (b) showed 98.8% (5 serum samples, 1:10 diluted in the range of 0.5–1.3 μg/L, compared to GFAAS determination, which was set to 100%), and accuracy was 96.8% or 105.6% for the serum or urine control material. Analysis time per sample was short and typically below 2 min for the complete measurement, including sample introduction, sample-line purge and quadruplicate Se determination.This method was used to determine Se in cerebrospinal fluid (CSF) and plasma (here parallel to GFAAS) in 35 paired serum and CSF samples. Se determination gave values in the range of 42–130 μg/L for serum and 1.63–6.66 μg/L for CSF. The median for Se in 35 individual CSF samples was 3.28 μg/L, the mean (±SD) was 3.67 (1.35) μg/L, whilst for individual serum samples the median was 81 μg/L and the mean (±SD) was 85 (26) μg/L. When relating the paired Se concentrations of CSF samples to respective serum samples it turned out that Se-CSF (behind blood brain barrier (BBB)) is independent on Se-serum concentration (before BBB).  相似文献   

17.
A high-performance liquid chromatographic method for the determination of picotamide in human plasma and urine is described. After addition of an internal standard (bamifylline), the plasma and urine samples were subjected to liquid—liquid extraction and clean-up procedures. The final extracts were evaporated to dryness and the resulting residues were reconstituted in 100 μl of methanol—water (50:50, v/v) and chromatographed on a LiChrosorb RP-SELECT B reversed-phase column coupled to an ultraviolet detector monitored at 230 nm. Chromatographic analysis takes about 10 min per sample. The assay was linear over a wide range and has a limit of detection of 0.005 and 0.1 μg/ml in plasma and urine, respectively. It was selective for picotamide, accurate and robust and thus suitable for routine assays after therapeutic doses of picotamide.  相似文献   

18.
We have developed a rapid and sensitive GC–MS assay for methylmalonic acid determination in serum and plasma utilizing an anion exchange solid-phase extraction and trimethylsilyl derivatization. Each step of the procedure was optimized by the experimental design methods to assure the assay reliable performance. The limit of detection and limit of quantitation were 0.025 and 0.1 μmol/l. The total coefficient of variation for the method was 9.8, 4.4, and 4.6% at the concentration of 0.2, 3.1, and 6.2 μmol/l methylmalonic acid concentration, respectively. The assay are linear up to 9.0 μmol/l, and showed good correlation with a reference method. The method has proven to be reliable in routine production, producing clean chromatography, unique ion fragments, and consistent ion mass ratio.  相似文献   

19.
Total fatty acids in plasma of neonates have been analysed as their methyl esters by gas chromatography. They were separated on a capillary column coated with a SP-2380 stationary phase. As little as 100 μl of plasma is used for the analysis. The extraction procedure was performed with dichloromethane—methanol (2:1) and fatty acids were methylated with boron trifluoride—methanol. The quantification of fatty acids is based on an internal standard method. Absolute values (μg fatty acid per 100 μl plasma) are given together with relative values (%). At a signal-to-noise ratio of 3, the detection limits for flame ionisation detection are between 0.08 to 0.51 ng. The high sensitivity and precision permits the effective determination of the fatty acids in neonate plasma.  相似文献   

20.
A rapid and sensitive method for extracting temazepam from human serum and urine is presented. Free temazepam is extracted from plasma and urine samples using n-butyl chloride with nitrazepam as the internal standard. Temazepam glucuronide is analyzed as free temazepam after incubating extracts with β-glucuronidase. Separation is achieved using a C8 reversed-phase column with a methanol—water—phosphate buffer mobile phase. An ultraviolet detector operated at 230 nm is used and a linear response is observed from 20 ng/ml to 10 μg/ml. The limit of detection is 15.5 ng/ml and the limit of quantitation is 46.5 ng/ml. Coefficients of variation are less than 10% for concentrations greater than 50 ng/ml. Application of the methodology is demonstrated in a pharmacokinetic study using eight healthy male subjects.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号