首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
It is a major challenge to develop effective sequence database search algorithms to translate molecular weight and fragment mass information obtained from tandem mass spectrometry into high quality peptide and protein assignments. We investigated the peptide identification performance of Mascot and X!Tandem for mass tolerance settings common for low and high accuracy mass spectrometry. We demonstrated that sensitivity and specificity of peptide identification can vary substantially for different mass tolerance settings, but this effect was more significant for Mascot. We present an adjusted Mascot threshold, which allows the user to freely select the best trade-off between sensitivity and specificity. The adjusted Mascot threshold was compared with the default Mascot and X!Tandem scoring thresholds and shown to be more sensitive at the same false discovery rates for both low and high accuracy mass spectrometry data.  相似文献   

2.
We report the first metabolic labeling of Arabidopsis thaliana for proteomic investigation, demonstrating efficient and complete labeling of intact plants. Using a reversed-database strategy, we evaluate the performance of the MASCOT search engine in the analysis of combined natural abundance and 15N-labeled samples. We find that 15N-metabolic labeling appears to increase the ambiguity associated with peptide identifications due in part to changes in the number of isobaric amino acids when the isotopic label is introduced. This is reflected by changes in the distributions of false positive identifications with respect to MASCOT score. However, by determining the nitrogen count from each pair of labeled and unlabeled peptides we may improve our confidence in both heavy and light identifications.  相似文献   

3.
Whereas the bearing of mass measurement error on protein identification is sometimes underestimated, uncertainty in observed peptide masses unavoidably translates to ambiguity in subsequent protein identifications. Although ongoing instrumental advances continue to make high accuracy mass spectrometry (MS) increasingly accessible, many proteomics experiments are still conducted with rather large mass error tolerances. In addition, the ranking schemes of most protein identification algorithms do not include a meaningful incorporation of mass measurement error. This article provides a critical evaluation of mass error tolerance as it pertains to false positive peptide and protein associations resulting from peptide mass fingerprint (PMF) database searching. High accuracy, high resolution PMFs of several model proteins were obtained using matrix-assisted laser desorption/ionization Fourier transform ion cyclotron resonance mass spectrometry (MALDI-FTICR-MS). Varying levels of mass accuracy were simulated by systematically modulating the mass error tolerance of the PMF query and monitoring the effect on figures of merit indicating the PMF quality. Importantly, the benefits of decreased mass error tolerance are not manifest in Mowse scores when operating at tolerances in the low parts-per-million range but become apparent with the consideration of additional metrics that are often overlooked. Furthermore, the outcomes of these experiments support the concept that false discovery is closely tied to mass measurement error in PMF analysis. Clear establishment of this relation demonstrates the need for mass error-aware protein identification routines and argues for a more prominent contribution of high accuracy mass measurement to proteomic science.  相似文献   

4.
The statistical validation of database search results is a complex issue in bottom-up proteomics. The correct and incorrect peptide spectrum match (PSM) scores overlap significantly, making an accurate assessment of true peptide matches challenging. Since the complete separation between the true and false hits is practically never achieved, there is need for better methods and rescoring algorithms to improve upon the primary database search results. Here we describe the calibration and False Discovery Rate (FDR) estimation of database search scores through a dynamic FDR calculation method, FlexiFDR, which increases both the sensitivity and specificity of search results. Modelling a simple linear regression on the decoy hits for different charge states, the method maximized the number of true positives and reduced the number of false negatives in several standard datasets of varying complexity (18-mix, 49-mix, 200-mix) and few complex datasets (E. coli and Yeast) obtained from a wide variety of MS platforms. The net positive gain for correct spectral and peptide identifications was up to 14.81% and 6.2% respectively. The approach is applicable to different search methodologies- separate as well as concatenated database search, high mass accuracy, and semi-tryptic and modification searches. FlexiFDR was also applied to Mascot results and showed better performance than before. We have shown that appropriate threshold learnt from decoys, can be very effective in improving the database search results. FlexiFDR adapts itself to different instruments, data types and MS platforms. It learns from the decoy hits and sets a flexible threshold that automatically aligns itself to the underlying variables of data quality and size.  相似文献   

5.
One of the challenges associated with large-scale proteome analysis using tandem mass spectrometry (MS/MS) and automated database searching is to reduce the number of false positive identifications without sacrificing the number of true positives found. In this work, a systematic investigation of the effect of 2MEGA labeling (N-terminal dimethylation after lysine guanidination) on the proteome analysis of a membrane fraction of an Escherichia coli cell extract by 2-dimensional liquid chromatography MS/MS is presented. By a large-scale comparison of MS/MS spectra of native peptides with those from the 2MEGA-labeled peptides, the labeled peptides were found to undergo facile fragmentation with enhanced a1 or a1-related (a(1)-17 and a(1)-45) ions derived from all N-terminal amino acids in the MS/MS spectra; these ions are usually difficult to detect in the MS/MS spectra of nonderivatized peptides. The 2MEGA labeling alleviated the biased detection of arginine-terminated peptides that is often observed in MALDI and ESI MS experiments. 2MEGA labeling was found not only to increase the number of peptides and proteins identified but also to generate enhanced a1 or a1-related ions as a constraint to reduce the number of false positive identifications. In total, 640 proteins were identified from the E. coli membrane fraction, with each protein identified based on peptide mass and sequence match of one or more peptides using MASCOT database search algorithm from the MS/MS spectra generated by a quadrupole time-of-flight mass spectrometer. Among them, the subcellular locations of 336 proteins are presently known, including 258 membrane and membrane-associated proteins (76.8%). Among the classified proteins, there was a dramatic increase in the total number of integral membrane proteins identified in the 2MEGA-labeled sample (153 proteins) versus the unlabeled sample (77 proteins).  相似文献   

6.
Reliable statistical validation of peptide and protein identifications is a top priority in large-scale mass spectrometry based proteomics. PeptideProphet is one of the computational tools commonly used for assessing the statistical confidence in peptide assignments to tandem mass spectra obtained using database search programs such as SEQUEST, MASCOT, or X! TANDEM. We present two flexible methods, the variable component mixture model and the semiparametric mixture model, that remove the restrictive parametric assumptions in the mixture modeling approach of PeptideProphet. Using a control protein mixture data set generated on an linear ion trap Fourier transform (LTQ-FT) mass spectrometer, we demonstrate that both methods improve parametric models in terms of the accuracy of probability estimates and the power to detect correct identifications controlling the false discovery rate to the same degree. The statistical approaches presented here require that the data set contain a sufficient number of decoy (known to be incorrect) peptide identifications, which can be obtained using the target-decoy database search strategy.  相似文献   

7.
Li N  Wu S  Zhang C  Chang C  Zhang J  Ma J  Li L  Qian X  Xu P  Zhu Y  He F 《Proteomics》2012,12(11):1720-1725
In this study, we presented a quality control tool named PepDistiller to facilitate the validation of MASCOT search results. By including the number of tryptic termini, and integrating a refined false discovery rate (FDR) calculation method, we demonstrated the improved sensitivity of peptide identifications obtained from semitryptic search results. Based on the analysis of a complex data set, approximately 7% more peptide identifications were obtained using PepDistiller than using MASCOT Percolator. Moreover, the refined method generated lower FDR estimations than the percentage of incorrect target (PIT) fixed method applied in Percolator. Using a standard data set, we further demonstrated the increased accuracy of the refined FDR estimations relative to the PIT-fixed FDR estimations. PepDistiller is fast and convenient to use, and is freely available for academic access. The software can be downloaded from http://www.bprc.ac.cn/pepdistiller.  相似文献   

8.
High-throughput protein identification in mass spectrometry is predominantly achieved by first identifying tryptic peptides by a database search and then by combining the peptide hits for protein identification. One of the popular tools used for the database search is SEQUEST. Peptide identification is carried out by selecting SEQUEST hits above a specified threshold, the value of which is typically chosen empirically in an attempt to separate true identifications from false ones. These SEQUEST scores are not normalized with respect to the composition, length and other parameters of the peptides. Furthermore, there is no rigorous reliability estimate assigned to the protein identifications derived from these scores. Hence, the interpretation of SEQUEST hits generally requires human involvement, making it difficult to scale up the identification process for genome-scale applications. To overcome these limitations, we have developed a method, which combines a neural network and a statistical model, for normalizing SEQUEST scores, and also for providing a reliability estimate for each SEQUEST hit. This method improves the sensitivity and specificity of peptide identification compared to the standard filtering procedure used in the SEQUEST package, and provides a basis for estimating the reliability of protein identifications.  相似文献   

9.
We present a wrapper-based approach to estimate and control the false discovery rate for peptide identifications using the outputs from multiple commercially available MS/MS search engines. Features of the approach include the flexibility to combine output from multiple search engines with sequence and spectral derived features in a flexible classification model to produce a score associated with correct peptide identifications. This classification model score from a reversed database search is taken as the null distribution for estimating p-values and false discovery rates using a simple and established statistical procedure. Results from 10 analyses of rat sera on an LTQ-FT mass spectrometer indicate that the method is well calibrated for controlling the proportion of false positives in a set of reported peptide identifications while correctly identifying more peptides than rule-based methods using one search engine alone.  相似文献   

10.
Mass spectrometry combined with database searching has become the preferred method for identifying proteins in proteomics projects. Proteins are digested by one or several enzymes to obtain peptides, which are analyzed by mass spectrometry. We introduce a new family of scoring schemes, named OLAV, aimed at identifying peptides in a database from their tandem mass spectra. OLAV scoring schemes are based on signal detection theory, and exploit mass spectrometry information more extensively than previously existing schemes. We also introduce a new concept of structural matching that uses pattern detection methods to better separate true from false positives. We show the superiority of OLAV scoring schemes compared to MASCOT, a widely used identification program. We believe that this work introduces a new way of designing scoring schemes that are especially adapted to high-throughput projects such as GeneProt large-scale human plasma project, where it is impractical to check all identifications manually.  相似文献   

11.
Ma J  Zhang J  Wu S  Li D  Zhu Y  He F 《Proteomics》2010,10(23):4293-4300
The probability-based search engine MASCOT has been widely used to identify peptides and proteins in shotgun proteomic research. Most subsequent quality control methods filter out ambiguous assignments according to the ion score and thresholds provided by MASCOT. On the basis of target-decoy database search strategy, we evaluated the performance of several filter methods on MASCOT search results and demonstrated that using filter boundaries on two-dimensional feature spaces, the MASCOT ion score and its relative score can improve the sensitivity of the filter process. Furthermore, using a linear combination of several characteristics of the assigned peptides, including the MASCOT scores, 15 previously employed features, and some newly introduced features, we applied a Bayesian nonparametric model to MASCOT search results and validated more correctly identified peptides in control and complex data sets than those could be validated by empirical score thresholds.  相似文献   

12.
Peptide identification using tandem mass spectrometry is a core technology in proteomics. Latest generations of mass spectrometry instruments enable the use of electron transfer dissociation (ETD) to complement collision induced dissociation (CID) for peptide fragmentation. However, a critical limitation to the use of ETD has been optimal database search software. Percolator is a post-search algorithm, which uses semi-supervised machine learning to improve the rate of peptide spectrum identifications (PSMs) together with providing reliable significance measures. We have previously interfaced the Mascot search engine with Percolator and demonstrated sensitivity and specificity benefits with CID data. Here, we report recent developments in the Mascot Percolator V2.0 software including an improved feature calculator and support for a wider range of ion series. The updated software is applied to the analysis of several CID and ETD fragmented peptide data sets. This version of Mascot Percolator increases the number of CID PSMs by up to 80% and ETD PSMs by up to 60% at a 0.01 q-value (1% false discovery rate) threshold over a standard Mascot search, notably recovering PSMs from high charge state precursor ions. The greatly increased number of PSMs and peptide coverage afforded by Mascot Percolator has enabled a fuller assessment of CID/ETD complementarity to be performed. Using a data set of CID and ETcaD spectral pairs, we find that at a 1% false discovery rate, the overlap in peptide identifications by CID and ETD is 83%, which is significantly higher than that obtained using either stand-alone Mascot (69%) or OMSSA (39%). We conclude that Mascot Percolator is a highly sensitive and accurate post-search algorithm for peptide identification and allows direct comparison of peptide identifications using multiple alternative fragmentation techniques.  相似文献   

13.
MassMatrix is a program that matches tandem mass spectra with theoretical peptide sequences derived from a protein database. The program uses a mass accuracy sensitive probabilistic score model to rank peptide matches. The MS/MS search software was evaluated by use of a high mass accuracy dataset and its results compared with those from MASCOT, SEQUEST, X!Tandem, and OMSSA. For the high mass accuracy data, MassMatrix provided better sensitivity than MASCOT, SEQUEST, X!Tandem, and OMSSA for a given specificity and the percentage of false positives was 2%. More importantly all manually validated true positives corresponded to a unique peptide/spectrum match. The presence of decoy sequence and additional variable PTMs did not significantly affect the results from the high mass accuracy search. MassMatrix performs well when compared with MASCOT, SEQUEST, X!Tandem, and OMSSA with regard to search time. MassMatrix was also run on a distributed memory clusters and achieved search speeds of ~100 000 spectra per hour when searching against a complete human database with eight variable modifications. The algorithm is available for public searches at http://www.massmatrix.net.  相似文献   

14.
Shotgun proteomics using mass spectrometry is a powerful method for protein identification but suffers limited sensitivity in complex samples. Integrating peptide identifications from multiple database search engines is a promising strategy to increase the number of peptide identifications and reduce the volume of unassigned tandem mass spectra. Existing methods pool statistical significance scores such as p-values or posterior probabilities of peptide-spectrum matches (PSMs) from multiple search engines after high scoring peptides have been assigned to spectra, but these methods lack reliable control of identification error rates as data are integrated from different search engines. We developed a statistically coherent method for integrative analysis, termed MSblender. MSblender converts raw search scores from search engines into a probability score for every possible PSM and properly accounts for the correlation between search scores. The method reliably estimates false discovery rates and identifies more PSMs than any single search engine at the same false discovery rate. Increased identifications increment spectral counts for most proteins and allow quantification of proteins that would not have been quantified by individual search engines. We also demonstrate that enhanced quantification contributes to improve sensitivity in differential expression analyses.  相似文献   

15.
A novel database search algorithm is presented for the qualitative identification of proteins over a wide dynamic range, both in simple and complex biological samples. The algorithm has been designed for the analysis of data originating from data independent acquisitions, whereby multiple precursor ions are fragmented simultaneously. Measurements used by the algorithm include retention time, ion intensities, charge state, and accurate masses on both precursor and product ions from LC‐MS data. The search algorithm uses an iterative process whereby each iteration incrementally increases the selectivity, specificity, and sensitivity of the overall strategy. Increased specificity is obtained by utilizing a subset database search approach, whereby for each subsequent stage of the search, only those peptides from securely identified proteins are queried. Tentative peptide and protein identifications are ranked and scored by their relative correlation to a number of models of known and empirically derived physicochemical attributes of proteins and peptides. In addition, the algorithm utilizes decoy database techniques for automatically determining the false positive identification rates. The search algorithm has been tested by comparing the search results from a four‐protein mixture, the same four‐protein mixture spiked into a complex biological background, and a variety of other “system” type protein digest mixtures. The method was validated independently by data dependent methods, while concurrently relying on replication and selectivity. Comparisons were also performed with other commercially and publicly available peptide fragmentation search algorithms. The presented results demonstrate the ability to correctly identify peptides and proteins from data independent acquisition strategies with high sensitivity and specificity. They also illustrate a more comprehensive analysis of the samples studied; providing approximately 20% more protein identifications, compared to a more conventional data directed approach using the same identification criteria, with a concurrent increase in both sequence coverage and the number of modified peptides.  相似文献   

16.

Background  

Rejection of false positive peptide matches in database searches of shotgun proteomic experimental data is highly desirable. Several methods have been developed to use the peptide retention time as to refine and improve peptide identifications from database search algorithms. This report describes the implementation of an automated approach to reduce false positives and validate peptide matches.  相似文献   

17.
We developed a probability-based machine-learning program, Colander, to identify tandem mass spectra that are highly likely to represent phosphopeptides prior to database search. We identified statistically significant diagnostic features of phosphopeptide tandem mass spectra based on ion trap CID MS/MS experiments. Statistics for the features are calculated from 376 validated phosphopeptide spectra and 376 nonphosphopeptide spectra. A probability-based support vector machine (SVM) program, Colander, was then trained on five selected features. Data sets were assembled both from LC/LC-MS/MS analyses of large-scale phosphopeptide enrichments from proteolyzed cells, tissues and synthetic phosphopeptides. These data sets were used to evaluate the capability of Colander to select pS/pT-containing phosphopeptide tandem mass spectra. When applied to unknown tandem mass spectra, Colander can routinely remove 80% of tandem mass spectra while retaining 95% of phosphopeptide tandem mass spectra. The program significantly reduced computational time spent on database search by 60-90%. Furthermore, prefiltering tandem mass spectra representing phosphopeptides can increase the number of phosphopeptide identifications under a predefined false positive rate.  相似文献   

18.

Background  

High-throughput shotgun proteomics data contain a significant number of spectra from non-peptide ions or spectra of too poor quality to obtain highly confident peptide identifications. These spectra cannot be identified with any positive peptide matches in some database search programs or are identified with false positives in others. Removing these spectra can improve the database search results and lower computational expense.  相似文献   

19.
A key problem in computational proteomics is distinguishing between correct and false peptide identifications. We argue that evaluating the error rates of peptide identifications is not unlike computing generating functions in combinatorics. We show that the generating functions and their derivatives ( spectral energy and spectral probability) represent new features of tandem mass spectra that, similarly to Delta-scores, significantly improve peptide identifications. Furthermore, the spectral probability provides a rigorous solution to the problem of computing statistical significance of spectral identifications. The spectral energy/probability approach improves the sensitivity-specificity tradeoff of existing MS/MS search tools, addresses the notoriously difficult problem of "one-hit-wonders" in mass spectrometry, and often eliminates the need for decoy database searches. We therefore argue that the generating function approach has the potential to increase the number of peptide identifications in MS/MS searches.  相似文献   

20.
Value of fine needle aspiration in the diagnosis of breast lesions.   总被引:2,自引:0,他引:2  
OBJECTIVE: To evaluate the accuracy values of 276 fine needle aspriations (FNA) of breast lesions with a subsequent excisional biopsy diagnosis and to make a comparison between 25 studies of the literature using the same criteria to calculate those values. STUDY DESIGN: Cytologic findings were compared with the histologic diagnosis of each mass. The correlation of results was analyzed by a decision-analysis approach, and the following values concerning diagnostic accuracy were calculated in the present study and in 25 other reports: sensitivity, specificity, positive predictive value, negative predictive value, false positive fraction and false negative fraction. To calculate those values, we eliminated unsatisfactory results and assumed that suspicious and positive cytologic findings represented carcinoma of the breast. RESULTS: Comparing our results with the means in the literature (numbers in parenthesis), FNA detected cancer with a sensitivity of 92.1% (87.7%), specificity of 98.6% (94.7%), positive predictive value of 99.4% (92.8%), negative predictive value of 82.1% (90.7%), false positive fraction of 0.6% (7.1%) and false negative fraction of 17.9% (13.4%); in 6.2% of cases the material was unsatisfactory (13.4%). CONCLUSION: All the rates varied enormously between the studies and during the past 13 years. It seems that false positive and false negative fractions tended to diminish and stabilize in more recent years, and specificity and sensitivity underwent a slight increase. The differences between the rates of those studies suggest that FNA of the breast has some unavoidable limitations.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号