首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
2.
We have developed an array biosensor for the simultaneous detection of multiple targets in multiple samples within 15-30 min. The biosensor is based on a planar waveguide, a modified microscope slide, with a pattern of small (mm2) sensing regions. The waveguide is illuminated by launching the emission of a 635 nm diode laser into the proximal end of the slide via a line generator. The evanescent field excites fluorophores bound in the sensing region and the emitted fluorescence is measured using a Peltier-cooled CCD camera. Assays can be performed on the waveguide in multichannel flow chambers and then interrogated using the detection system described here. This biosensor can detect many different targets, including proteins, toxins, cells, virus, and explosives with detection limits rivaling those of the ELISA detection system.  相似文献   

3.
A high density microelectrode array biosensor was developed for the detection of Escherichia coli O157:H7. The biosensor was fabricated from (100) silicon with a 2 microm layer of thermal oxide as an insulating layer, an active area of 9.6 mm2 and consists of an interdigitated gold electrode array. The sensor surface was functionalised for bacterial detection using heterobifunctional crosslinkers and immobilised polyclonal antibodies to create a biological sensing surface. Bacteria suspended in solution became attached to the immobilised antibodies when the biosensor was tested in liquid samples. The change in impedance caused by the bacteria was measured over a frequency range of 100 Hz-10 M Hz. The biosensor was evaluated for E. coli O157:H7 detection in pure culture and inoculated food samples. The biosensor was able to discriminate between cellular concentrations of 10(4)-10(7)CFU/mL and has applications in detecting pathogens in food samples.  相似文献   

4.
Recently, we demonstrated that an array biosensor could be used with cocktails of fluorescent antibodies to perform three assays simultaneously on a single substrate, and that multiple samples could be analyzed in parallel. We extend this technology to demonstrate the simultaneous analysis of six samples for six different hazardous analytes, including both bacteria and protein toxins. The level of antibody cross-reactivity is explored, revealing a possible common epitope in two of the toxins. A panel of environmental interferents was added to the samples; these interferents neither prevented the detection of the analytes nor caused false-positive responses.  相似文献   

5.

Many environmental applications exist for biosensors capable of providing real-time analyses. One pressing current need is monitoring for agents of chemical- and bio-terrorism. These applications require systems that can rapidly detect small organics including nerve agents, toxic proteins, viruses, spores and whole microbes. A second area of application is monitoring for environmental pollutants. Processing of grab samples through chemical laboratories requires significant time delays in the analyses, preventing the rapid mapping and cleanup of chemical spills. The current state of development of miniaturized, integrated surface plasmon resonance (SPR) sensor elements has allowed for the development of inexpensive, portable biosensor systems capable of the simultaneous analysis of multiple analytes. Most of the detection protocols make use of antibodies immobilized on the sensor surface. The Spreeta 2000 SPR biosensor elements manufactured by Texas Instruments provide three channels for each sensor element in the system. A temperature-controlled two-element system that monitors for six analytes is currently in use, and development of an eight element sensor system capable of monitoring up to 24 different analytes will be completed in the near future. Protein toxins can be directly detected and quantified in the low picomolar range. Elimination of false positives and increased sensitivity is provided by secondary antibodies with specificity for different target epitopes, and by sensor element redundancy. Inclusion of more than a single amplification step can push the sensitivity of toxic protein detection to femtomolar levels. The same types of direct detection and amplification protocols are used to monitor for viruses and whole bacteria or spores. Special protocols are required for the detection of small molecules. Either a competition type assay where the presence of analyte inhibits the binding of antibodies to surface-immobilized analyte, or a displacement assay, where antibodies bound to analyte on the sensor surface are displaced by free analyte, can be used. The small molecule detection assays vary in sensitivity from the low micromolar range to the high picomolar.

  相似文献   

6.
Many environmental applications exist for biosensors capable of providing real-time analyses. One pressing current need is monitoring for agents of chemical- and bio-terrorism. These applications require systems that can rapidly detect small organics including nerve agents, toxic proteins, viruses, spores and whole microbes. A second area of application is monitoring for environmental pollutants. Processing of grab samples through chemical laboratories requires significant time delays in the analyses, preventing the rapid mapping and cleanup of chemical spills. The current state of development of miniaturized, integrated surface plasmon resonance (SPR) sensor elements has allowed for the development of inexpensive, portable biosensor systems capable of the simultaneous analysis of multiple analytes. Most of the detection protocols make use of antibodies immobilized on the sensor surface. The Spreeta 2000 SPR biosensor elements manufactured by Texas Instruments provide three channels for each sensor element in the system. A temperature-controlled two-element system that monitors for six analytes is currently in use, and development of an eight element sensor system capable of monitoring up to 24 different analytes will be completed in the near future. Protein toxins can be directly detected and quantified in the low picomolar range. Elimination of false positives and increased sensitivity is provided by secondary antibodies with specificity for different target epitopes, and by sensor element redundancy. Inclusion of more than a single amplification step can push the sensitivity of toxic protein detection to femtomolar levels. The same types of direct detection and amplification protocols are used to monitor for viruses and whole bacteria or spores. Special protocols are required for the detection of small molecules. Either a competition type assay where the presence of analyte inhibits the binding of antibodies to surface-immobilized analyte, or a displacement assay, where antibodies bound to analyte on the sensor surface are displaced by free analyte, can be used. The small molecule detection assays vary in sensitivity from the low micromolar range to the high picomolar.  相似文献   

7.
Using a newly developed fluorescent nanoparticle (NP) that gives rise to a high-intensity and stable fluorescent light, a sensitive antibody (Ab) microarray assay system has been developed for specific detection of bioterrorism agents, as exemplified by ricin, cholera toxin (CT), and staphylococcal enterotoxin B (SEB). The Ab microarray uses a sandwich format that consists of capture Abs, analytes (toxins), biotinylated detection Abs, and avidin-conjugated NP. In all three cases, polyclonal Abs (pAbs) displayed superiority over monoclonal antibodies (mAbs) in capturing toxins on microarray slides even when the pAbs and mAbs had similar affinity as determined by enzyme-linked immunosorbent assay (ELISA). The detection system was successfully used to detect toxins spiked in milk, apple cider, and blood samples. We were able to detect ricin at 100 pg/ml in buffer and at 1 ng/ml in spiked apple cider or milk, whereas CT and SEB were detected at 10 pg/ml in buffer and 100 pg/ml in spiked apple cider or milk. High specificities were also demonstrated in the detection of mixed toxin samples with similar sensitivities. The matrix effect of blood samples on the detection of mixed toxins seems to be minimal when the toxin concentration is at or above 100 ng/ml. The current study highlights the significant role of pAb and NP in increasing selectivity and sensitivity of toxin detection in a microarray format.  相似文献   

8.
An optical waveguide array biosensor suitable for rapid detection of multiple bio-hazardous agents is presented. SpectroSens? optical microchip sensors contain multiple spatially-separated waveguide channels with integral high-precision Bragg gratings sensitive to changes in refractive-index; selective surface-functionalisation of discrete sensing channels with different antibodies as bio-recognition elements enables selective multi-analyte biological detection. Interactions between target antigens in the test sample and respective surface-immobilised antibodies result in localised changes in refractive-index; the biosensor response manifests as increases in wavelength of light reflected from specific sensing channels. Multiplexed, label-free detection of 8 different biological agents, encompassing bacterial spores, vegetative cells, viruses and proteinaceous toxins has been demonstrated in real-time. Selective detection of Bacillus atrophaeus (BG) spores, Escherichia coli cells, MS2 viruses and ovalbumin (OVA) protein (simulant bio-hazardous agents) was first demonstrated as proof-of-concept; subsequently, detection of Bacillus anthracis (BA) spores (UM23CL2 strain), Franciscella tularensis (FT) cells (live vaccine strain), Vaccinia viruses (heat-killed) and ricin toxin (bio-hazardous agents) was proven. Two optical microchip sensors, each comprising 8 sensing channels were packaged into a single disposable cartridge allowing simultaneous 16-channel data acquisition. The specific antibody deposition sequence used in this study enabled detection of either 4 simulants or 4 bio-hazardous agents using a single consumable. The final device, a culmination of the multidisciplinary convergence of the fields of biology, chemistry, optoelectronics and microfluidics, is man-portable and inherently robust. The performance characteristics of the SpectroSens? technology platform highlight its potential for exploitation as a ‘detect to warn/treat’ biodetector in security and defence operations.  相似文献   

9.
An intestinal protozoan parasite, Cryptosporidium parvum, is a major cause of waterborne gastrointestinal disease worldwide. Detection of Cryptosporidium oocysts in potable water is a high priority for the water treatment industry to reduce potential outbreaks among the consumer populace. Anti-Cryptosporidium oocyst polyclonal and monoclonal antibodies were tested as capture and detection reagents for use in a fiber optic biosensor assay for the detection of Cryptosporidium oocysts. Antibodies were validated using enzyme-linked immunosorbent assays, flow cytometry, Western blotting and fluorescent microscopy. Oocysts could be detected at a concentration of 105 oocysts/ml when the polyclonal antibodies were used as the capture and detection reagents. When oocysts were boiled prior to detection, a ten-fold increase in sensitivity was achieved using the polyclonal antibody. Western blotting and immunofluorescence revealed that both the monoclonal and polyclonal antibodies recognize a large (>300 kDa) molecular weight mucin-like antigen present on the surface of the oocyst wall. The polyclonal antibody also reacted with a small (105 kDa) molecular weight antigen that was present in boiled samples of oocysts. Preliminary steps to design an in-line biosensor assay system have shown that oocysts would have to be concentrated from water samples and heat treated to allow detection by a biosensor assay.  相似文献   

10.
Methods of myoglobin determination based on electrochemical analysis by means of analysis of electrochemical parameters of modified electrodes have been proposed. The method of direct detection is based on interaction of myoglobin with anti-myoglobin with subsequent electrochemical registration of this hemoprotein. The electrode surface was modified by a membrane-like synthetic didodecyldimethylammonium bromide (DDAB), gold nanoparticles and antibodies to human cardiac myoglobin the electrochemical reduction of myoglobin heme was registered provided that the antigen (myoglobin) was present in the samples. The reaction of myoglobin binding to antibodies immobilized on the electrode surface was also registered using electrochemical impedance spectroscopy. The study of electro analytical characteristics revealed high specificity and sensitivity of the developed method. The biosensor was characterized by low detection limit and a high working range of the detected concentrations from 17.8 to 1780 ng/ml (from 1 to 100 nM). The method of myoglobin determination based on a signal of gold nanoparticles has also been proposed. The signal was detected with stripping voltammetry. There was a change in the cathodic peak area and the peak height of gold oxide reduction for the electrodes with antibodies and the electrodes with the antibody-myoglobin complex.  相似文献   

11.
Immunological diagnostic methods have been widely performed and showed high performance in molecular and cellular biology, molecular imaging, and medical diagnostics. We have developed novel methods for the fluorescent labeling of several antibodies coupled with fluorescent nanocrystal QDs. In this study we demonstrated that two bacterial toxins, diphtheria toxin and tetanus toxin, were detected simultaneously in the same view field of a cover slip by using directly QD-conjugated antibodies. We have succeeded in detecting bacterial toxins by counting luminescent spots on the evanescent field with using primary antibody conjugated to QDs. In addition, each bacterial toxin in the mixture can be separately detected by single excitation laser with emission band pass filters, and simultaneously in situ pathogen quantification was performed by calculating the luminescent density on the surface of the cover slip. Our results demonstrate that total internal reflection fluorescence microscopy (TIRFM) enables us to distinguish each antigen from mixed samples and can simultaneously quantitate multiple antigens by QD-conjugated antibodies . Bioconjugated QDs could have great potentialities for in practical biomedical applications to develop various high-sensitivity detection systems.  相似文献   

12.
A simple and versatile miniaturized surface plasmon resonance (SPR) immunosensor enabling parallel analysis of multiple analytes or multiple samples of an analyte has been investigated for detection of a low-molecular-weight (lmw) toxin, 2,4-dichlorophenoxyacetic acid (2,4-D). A specially designed multi-microchannel SPR sensor module, integrating an optical-prism coated with an array of thin Au-films, a multi-microchannel plate (eight channels) and a flow-cell together, has been fabricated. The sensing surface was fabricated simply by physical adsorption of a protein conjugate of 2,4-D, and an indirect competitive immunoassay principle has been applied for the quantification of 2,4-D. Multiple 2,4-D samples were analyzed in a single step and a low-detection-limit (LDL) of 0.1 ppb (ng ml(-1)) 2,4-D was established. Competence of the portable SPR immunosensor for selective detection of 2,4-D despite the presence of various structurally resemblant interferents and from river-water samples has been demonstrated. The independent all-in-one sensor module highly favors shelf-storage between multiple determinations, and reusability of a same multi-microchannel flow-module for more than 35 days with intermittent storage (4-8 degrees C) has been confirmed. The LDL of 2,4-D could be enhanced further by introducing a simple avidin-biotin interaction-based sandwich immunoassay, with which the sensor signal multiplied enormously by a factor of ca. 10 and the LDL enhanced to 0.008 ppb. The miniature SPR sensor demonstrated here for simultaneous analysis of multiple samples with reusability and good storage ability is an important consideration for the advancement of biosensor technology.  相似文献   

13.
Prostate-specific antigen (PSA) is a valuable biomarker for prostate cancer screening. We developed a PSA immunoassay on a commercially available surface plasmon resonance biosensor. Our PSA receptor molecule consists of a single domain antigen-binding fragment, cAbPSA-N7, derived from dromedary heavy-chain antibodies and identified after phage display. It binds PSA with a high k(on) value of 1.9x10(6) M-1 s-1, and was covalently immobilised on a gold substrate via a mixed self-assembled monolayer (SAM) of alkanethiols by using carbodiimide-coupling chemistry in 10mM acetate buffer pH 5.5 to obtain an optimal pre-concentration. The best performing and optimised mixed SAM consisted of (10%) 16-mercapto-1-hexadecanoic acid (16-MHA) for covalent cAbPSA-N7 immobilisation and (90%) 11-mercapto-1-undecanol (11-MUOH) to minimise non-specific adsorption of the analyte. In this way, two advantages are incorporated in a single coupling layer. Up to 28 fmol/mm2 of cAbPSA-N7 could be immobilised and 30% of its binding sites participate actively in PSA interaction. In addition, the optimised layer showed also optimal performance to assess physiological samples. Although PSA concentrations as low as 10 ng/ml could be detected directly, this detection limit could be enhanced to PSA levels in the sub ng/ml range by introducing a sandwich assay involving a biotinylated secondary antibody and streptavidin modified gold nanoparticles. This approach realizes the PSA detection at clinical relevant concentrations.  相似文献   

14.
The detection of hepatitis B virus surface antigen (HBsAg) with the use of a model IAsys+ two-channel optical biosensor is based on the registration of interaction between anti-HBs monoclonal antibodies forming the surface layer of the biochip of the biosensor cuvette and blood serum HBsAg. For the first time a two-channel optical biosensor has been used for the detection of HBsAg in blood serum samples. The comparative analysis of the detection of HBsAg by two methods, viz. with the use of an optical biosensor and the enzyme immunoassay, has demonstrated lower sensitivity, but higher specificity of the detection of this antigen by means of a model IAsys+ biosensor with the biochip, prepared in the process of the work. The main advantages of the biosensor detection lie in the registration of interaction in real time without introducing special markers into the molecules under study.  相似文献   

15.
An impedance biosensor based on interdigitated array microelectrode (IDAM) coupled with magnetic nanoparticle-antibody conjugates (MNAC) was developed and evaluated for rapid and specific detection of E. coli O157:H7 in ground beef samples. MNAC were prepared by immobilizing biotin-labeled polyclonal goat anti-E. coli antibodies onto streptavidin-coated magnetic nanoparticles, which were used to separate and concentrate E. coli O157:H7 from ground beef samples. Magnitude of impedance and phase angle were measured in a frequency range of 10 Hz to 1 MHz in the presence of 0.1M mannitol solution. The lowest detection limits of this biosensor for detection of E. coli O157:H7 in pure culture and ground beef samples were 7.4 x 10(4) and 8.0 x 10(5)CFU ml(-1), respectively. The regression equation for the normalized impedance change (NIC) versus E. coli O157:H7 concentration (N) in ground beef samples was NIC=15.55 N-71.04 with R(2)=0.95. Sensitivity of the impedance biosensor was improved by 35% by concentrating bacterial cells attached to MNAC in the active layer of IDAM above the surface of electrodes with the help of a magnetic field. Based on equivalent circuit analysis, it was observed that bulk resistance and double layer capacitance were responsible for the impedance change caused by the presence of E. coli O157:H7 on the surface of IDAM. Surface immobilization techniques, redox probes, or sample incubation were not used in this impedance biosensor. The total detection time from sampling to measurement was 35 min.  相似文献   

16.
Sensors that provide reliable, rapid measurement of toxic substances are needed to solve significant human health and safety problems. We developed a new biosensor design that combines the advantages of immunoassay with electrochemical response. We established that this enzyme-linked immunosensor measures toxic substances in biological samples. The biosensor consists of two major elements: (1) an electrical conducting layer having immobilized enzyme, polyclonal or monoclonal antibodies, and other necessary reagents, and (2) the electronic components used in the signal readout. The result is an amperometric immunoassay based on coupling the immunochemical reaction to the enzyme electrode response by using a soluble, electrochemically active mediator. The specific question addressed was: Does the system's immunochemical detection reliably respond at sufficiently low analyte concentrations? We present our results in these areas: (1) enzyme immobilization on colloidal gold; (2) colloidal gold-enzyme deposition on the electrode surface; (3) mediator-antigen conjugate synthesis; (4) antibody incorporation at the electrode surface; (5) bioelectrode characterization and optimization; and (6) immunosensor demonstration to detect antigen. Sensors that employ immunochemical detection will have broad applicability to detect/diagnose toxic substances in biological samples such as blood and urine and in environmental samples such as wastewater and drinking water.  相似文献   

17.
Immunization of BALB/c mice by horse antiserum against diphtheria made it possible to obtain IgG1 monoclonal antibodies (MoAbs) 2B7E4 specific for light chains of horse immunoglobulin (Ig). Unlike commercial preparations of anti-horse immunoglobulin antibodies, which are specific for the whole Ig molecule or its Fc-fragment, the peroxidase (HRP) conjugate of the MoAb, 2B7E4-HRP did not interact with human, mouse, rabbit, and sheep Igs, or horse albumin. The conjugate obtained was used with MoAbs against bacterial toxins and commercial horse antitoxins, as a universal reagent in sandwich enzyme immunoassay (ELISA) for bacterial toxins and toxoids. The detection sensitivity of diphtheria toxin/toxoid equaled 0.0005 Lf/ml; tetanus toxin and toxoid were detected with sensitivities of 20 LD50/ml and 0.005 UI/ml, respectively. A similar sandwich ELISA for botulinum toxoids (group measurement) allowed types A, B, and E to be detected at 0.02, 0.002, and 0.001 UI/ml, respectively; selective measurement was only possible in the case of type E toxoid (0.001 UI/ml).  相似文献   

18.
The aim of the present work is to develop an evanescence wave array biosensor exploiting the “kinetic” approach of enzymatic reaction and further detection of the reaction products via pH sensitive fluorophore reporter. To demonstrate the feasibility of this approach, we have developed a biosensor array with the potential for direct detection of organophosphates using as a biorecognition element, an enzyme organophosphorus hydrolase (OPH), conjugated with a pH-sensitive fluorophore, carboxynaphthofluorescein (CNF). The presence of reference spots allows the discrimination of the enzymatic and non-enzymatic based pH changes; bovine serum albumin (BSA) was used as a non-enzymatic scaffold protein for CNF attachment at the reference spots. An array biosensor unit developed at the Naval Research Laboratories (NRL) was adopted as the detection platform and appropriately modified for enzyme-based measurements. A planar multi-mode waveguide was covered with an optically transparent TiO2 layer to increase the surface area available for immobilization.

The biosensor enabled the detection of 2.5 μM paraoxon, and 10 μM DFP and parathion, respectively. Very short response time of 30 s can be achieved with a total analysis time of less than 2 min. When operated at room temperature and stored at 4 °C, the waveguide retained reasonable activity for greater than 45 days.  相似文献   


19.
One of the known limitations for biosensor assays is the high limit of detection for target cells within complex samples (e.g., Escherichia coli at 10(4) to 10(5) CFU/mL) due to poor capture efficiencies. Currently, researchers can only estimate the cell capture efficiency necessary to produce a positive signal for any type of biosensor using either cumbersome techniques or regression modeling. To solve this problem, green fluorescent protein (GFP) transformed E. coli O157:H7 was used to develop a novel method for directly and easily measuring the cell capture efficiency of any given biosensor platform. For demonstration purposes, E. coli-GFP was assayed on both fiber optic and planar waveguide biosensor platforms. Cells were enumerated using an epifluorescent microscope and digital camera to determine the number of cells captured on the surfaces. Conversion algorithms were used with these digital images to determine the cell density of entire waveguide surface areas. For E. coli-GFP, the range of cell capture efficiency was between 0.4 and 1.2%. This indicates that although the developed model works for calculating cell capture, there is still need for significant improvements in capture methods themselves, to increase the capture efficiency and thereby lower detection limits. The use of GFP-transformed target cells and cell capture efficiency calculations can facilitate the development and optimization processes by allowing direct enumeration of new biosensor design configurations and sample processing strategies.  相似文献   

20.
Viruses are of high medical and biodefense concern and their detection at concentrations well below the threshold necessary to cause health hazards continues to be a challenge with respect to sensitivity, specificity, and selectivity. Ideally, assays for accurate and real time detection of viral agents would not necessitate any pre-processing of the analyte, which would make them applicable for example to bodily fluids (blood, sputum) and man-made as well as naturally occurring bodies of water (pools, rivers). We describe herein a robust biosensor that combines the sensitivity of surface acoustic waves (SAW) generated at a frequency of 325MHz with the specificity provided by antibodies for the detection of viral agents. A lithium tantalate-based SAW transducer with silicon dioxide waveguide sensor platform featuring three test and one reference delay lines was used to adsorb antibodies directed against either Coxsackie virus B4 or the category A bioagent Sin Nombre virus (SNV), a member of the genus Hantavirus, family Bunyaviridae, negative-stranded RNA viruses. Rapid detection (within seconds) of increasing concentrations of viral particles was linear over a range of order of magnitude for both viruses, although the sensor was approximately 5 x 10(5)-fold more sensitive for the detection of SNV. For both pathogens, the sensor's selectivity for its target was not compromised by the presence of confounding Herpes Simplex virus type 1. The biosensor was able to detect SNV at doses lower than the load of virus typically found in a human patient suffering from hantavirus cardiopulmonary syndrome (HCPS). Further, in a proof-of-principle real world application, the SAW biosensor was capable to selectively detect SNV agents in complex solutions, such as naturally occurring bodies of water (river, sewage effluent) without analyte pre-processing. This is the first study that reports on the detection of viral agents using an antibody-based SAW biosensor that has the potential to be used as a hand-held and self-contained device for rapid viral detection in the field.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号