1.
Two Jehovah's Witnesses with large ascending thoracic aortic aneurysms and aortic insufficiency secondary to annuloaortic ectasia underwent successful combined replacement of the aortic valve and the ascending aorta. One patient received a composite graft containing an aortic valve prosthesis, which necessitated supravalvular coronary ostia reimplantation; the other patient underwent separate aortic valve and left supracoronary ascending aneurysm replacement, with reimplantation of the right coronary ostium into the graft. No blood or blood derivatives were administered. Both patients had uneventful recoveries and continue to do well. To our knowledge, they represent the first reported cases of successful combined replacement of the aortic valve and ascending aorta in Jehovah's Witnesses.  相似文献   

2.
Four cases of severe mitral regurgitation due to disc variance of the Harken disc prosthesis in the mitral position are described. The valve occluder actually escaped into the left atrium in two patients, and neither survived despite emergency valve replacement. In the other two, disc malfunction was identified by flouroscopy, the prosthesis was replaced, and both patients survived. All four patients had associated aortic regurgitation, which most likely contributed to erosion of the disc edges. It is suggested that patients with the Harken disc prosthesis undergo periodic evaluation to detect abnormal disc motion.  相似文献   

3.
This case report describes a useful and unusual route for insertion of an intraaortic balloon in 63-year-old man who was operated upon for calcific aortic stenosis, coronary atherosclerosis involving the left anterior descending and right coronary arteries, and a large abdominal aortic aneurysm. Aortic valve replacement was accomplished with a porcine heterograft prosthesis. Bypasses to the left anterior descending and right coronary arteries were constructed with reversed saphenous vein grafts, and the abdominal aneurysm was resected and repaired with a bifurcated woven Dacron vascular graft. An electively placed intraaortic balloon was inserted through the right limb of the aortic graft prosthesis and used to assist the patient during the immediate postoperative period. Uneventful recovery ensued.  相似文献   

4.

Background/Objectives

To evaluate the predictive value of CT-derived measurements of the aortic annulus for prosthesis sizing in transcatheter aortic valve implantation (TAVI) and to calculate optimal cutoff values for the selection of various prosthesis sizes.

Methods

The local IRB waived approval for this single-center retrospective analysis. Of 441 consecutive TAVI-patients, 90 were excluded (death within 30 days: 13; more than mild aortic regurgitation: 10; other reasons: 67). In the remaining 351 patients, the CoreValve (Medtronic) and the Edwards Sapien XT valve (Edwards Lifesciences) were implanted in 235 and 116 patients. Optimal prosthesis size was determined during TAVI by inflation of a balloon catheter at the aortic annulus. All patients had undergone CT-angiography of the heart or body trunk prior to TAVI. Using these datasets, the diameter of the long and short axis as well as the circumference and the area of the aortic annulus were measured. Multi-Class Receiver-Operator-Curve analyses were used to determine the predictive value of all variables and to define optimal cutoff-values.

Results

Differences between patients who underwent implantation of the small, medium or large prosthesis were significant for all except the large vs. medium CoreValve (all p’s<0.05). Furthermore, mean diameter, annulus area and circumference had equally high predictive value for prosthesis size for both manufacturers (multi-class AUC’s: 0.80, 0.88, 0.91, 0.88, 0.88, 0.89). Using the calculated optimal cutoff-values, prosthesis size is predicted correctly in 85% of cases.

Conclusion

CT-based aortic root measurements permit excellent prediction of the prosthesis size considered optimal during TAVI.  相似文献   

5.
John C. Callaghan 《CMAJ》1964,91(9):411-421
The aortic and mitral valves were replaced in 50 patients at the University of Alberta Hospital using the Starr-Edwards ball-valve prosthesis. The basis of the selection of 20 patients for isolated aortic valve replacement and 27 for mitral valve replacement using this type of prosthesis is presented, and the techniques of insertion of the aortic and mitral valve are described in detail. Of the 27 patients in whom the mitral valve was replaced by the Starr-Edwards prosthesis six died within 30 days of surgery and two after discharge from hospital at two and a half and four months, respectively. Left atrial thrombosis was the cause of death in four of these patients. In 20 patients in whom the aortic valve was replaced, four died in hospital and two died more than 30 days after returning home. Three of these six patients died from bleeding—the result of the use of anticoagulants. The difficulty in assessing whether or not anticoagulants are needed following replacement by a Starr-Edwards prosthesis is considered. It is felt, in our present state of knowledge, that anticoagulants should be used following mitral valve replacement but are probably not essential following replacement of the aortic valve. Two patients survived replacement of both aortic and mitral valves and have been followed up 18 months and seven months, respectively.  相似文献   

6.
Current artificial heart valves either have limited lifespan or require the recipient to be on permanent anticoagulation therapy. In this paper, effort is made to assess a newly developed bileaflet valve prosthesis made of synthetic flexible leaflet materials, whose geometry and material properties are based on those of the native mitral valve, with a view to providing superior options for mitral valve replacement. Computational analysis is employed to evaluate the geometric and material design of the valve, by investigation of its mechanical behaviour and unsteady flow characteristics. The immersed boundary (IB) method is used for the dynamic modelling of the large deformation of the valve leaflets and the fluid-structure interactions. The IB simulation is first validated for the aortic prosthesis subjected to a hydrostatic loading. The predicted displacement fields by IB are compared with those obtained using ANSYS, as well as with experimental measurements. Good quantitative agreement is obtained. Moreover, known failure regions of aortic prostheses are identified. The dynamic behaviour of the valve designs is then simulated under four physiological pulsatile flows. Experimental pressure gradients for opening and closure of the valves are in good agreement with IB predictions for all flow rates for both aortic and mitral designs. Importantly, the simulations predicted improved physiological haemodynamics for the novel mitral design. Limitation of the current IB model is also discussed. We conclude that the IB model can be developed to be an extremely effective dynamic simulation tool to aid prosthesis design.  相似文献   

7.
Over an eight-month period beginning in November 1969, 53 patients received 63 fascia lata heart valves at the Toronto General Hospital. The late results of this form of valve substitution are reviewed. The fascia used to fashion the tricuspid valve underwent progressive thickening and contracture and this process caused failure of the prosthesis within months of insertion. The mitral fascial prosthesis failed in a similar manner although the process took longer. The aortic fascia lata valve, however, has not shown progressive thickening after 3½ years and it has so far retained its functional integrity. Indeed, we have been impressed by the excellent clinical results and absence of complications such as thromboembolism although anticoagulation has not been used. We therefore consider that fascia lata valves offer a suitable alternative to other forms of aortic valve substitution, but are unsatisfactory for tricuspid or mitral valve replacement.  相似文献   

8.
The guard cells of Helianthus annuus contain elements of endoplasmic reticulum and large numbers of mitochondria and dictyosomes. Each guard cell possesses a complex system of small to large vacuoles which contain small, membrane-bound vesicles; the vacuole may actually be one highly invaginated and dissected vacuole extending throughout the cell. A highly developed grana fretwork within the plastids implies full photosynthetic capability and the capability of producing the osmoticulum required for turgor change. No plasmodesmata occur between the sister guard cells or between the guard and epidermal cells. It is postulated that there is a close relationship between plastid development and the presence or absence of plasmodesmata. No microbodies were positively identified in any of the guard cells. Microtubules appear to lie in two planes, thereby giving support to the “two system” observation for microtubules in the guard cells of Pisum sativum.  相似文献   

9.
Three cases of acute rupture of the aortic cusp complicating bacterial endocarditis are described. Special emphasis is placed on the value of serial echocardiography as a means of identifying progressive changes in aortic valve anatomy during the destructive process of the disease. Prior to the results of blood cultures, an echocardiogram confirmed a diagnosis of vegetations on the valve cusps. It also demonstrated flailing of the aortic cusp, which was confirmed at operation. Echocardiographic findings of flailing aortic valves in these patients coincided with the onset of acute aortic insufficiency and contributed to the timing of surgical intervention for replacement of the affected valves.  相似文献   

10.
Woven Dacron grafts are currently used for the surgical treatment of aortic aneurysm and acute dissection, two otherwise fatal pathologies when aortic wall rupture occurs. While Dacron is chosen for aortic grafts because of characteristics such as biocompatibility and durability, few data are available about the dynamic response of Dacron prosthetic devices and about their side effects on the cardiovascular system. In this study, a Dacron graft was subjected to physiological flow conditions in a specifically-developed mock circulatory loop. Experiments were conducted at different physiological pulsation-per-minute rates. Results show that, in comparison to an aortic segment of the same length, the prosthesis is extremely stiffer circumferentially, thus limiting the dynamical radial expansion responsible for the Windkessel effect in human arteries. The prosthesis is instead excessively compliant in the axial direction and develops preferentially bending oscillations. This very different dynamic behaviour with respect to the human aorta can alter cardiovascular pressure and flow dynamics resulting in long-term implant complications.  相似文献   

11.
12.
Summary The formation of a neo-intima in textile prostheses implanted in the rat and dog aorta was studied by means of light- and scanning electron microscopy. Two independent cellular layers (the superficial and deep ingrowth layers) developed on the free surface and under the fibrin layer initially deposited on the inner surface of the prostheses. The superficial ingrowth layer invades the prosthesis from both the proximal and distal aortic stumps and extends over the primary fibrin layer, or replaces it. This layer consists mainly of smooth muscle cells of the triangular aortic type covered by endothelial-like cells. The deep ingrowth layer originates from cellular elements of the prosthetic bed. Fibroblasts, myofibroblasts and spindle-shaped smooth muscle cells invade the fibrin layer through the interstices of the fabric structure of the prosthesis. Precursors of endothelial cells, however, are absent from this population. The superficial and the deep ingrowth layers may become joined by progressive replacement of the fibrin layer, but remain distinguishable because of their different cellular components.When a continuous cellular layer is established on the inner surface of the prosthesis, and this is then covered by endothelial-like cells, the neo-intima formed remains stable during long-term studies.  相似文献   

13.
Ronald J. Baird  Irving H. Lipton 《CMAJ》1965,92(21):1099-1105
The changes and improvements in the surgical treatment of aortic valve disease in 296 patients, who were operated on between 1953 and 1965, are illustrated and discussed in general terms. Several of the early techniques, such as transventricular dilation, insertion of a homograft aortic valve in the descending thoracic aorta, fabric replacement of one cusp or the entire valve, and ice-chip arrest of the heart, are now obsolete. Total replacement with a ball-valve prosthesis or an aortic valve homograft while the coronary arteries are perfused with blood is the currently popular technique. The results of a hemodynamic follow-up study two years after surgery are also included.  相似文献   

14.
Until recently, heart valve failure has been treated adopting open-heart surgical techniques and cardiopulmonary bypass. However, over the last decade, minimally invasive procedures have been developed to avoid high risks associated with conventional open-chest valve replacement techniques. Such a recent and innovative procedure represents an optimal field for conducting investigations through virtual computer-based simulations: in fact, nowadays, computational engineering is widely used to unravel many problems in the biomedical field of cardiovascular mechanics and specifically, minimally invasive procedures. In this study, we investigate a balloon-expandable valve and we propose a novel simulation strategy to reproduce its implantation using computational tools. Focusing on the Edwards SAPIEN valve in particular, we simulate both stent crimping and deployment through balloon inflation. The developed procedure enabled us to obtain the entire prosthetic device virtually implanted in a patient-specific aortic root created by processing medical images; hence, it allows evaluation of postoperative prosthesis performance depending on different factors (e.g. device size and prosthesis placement site). Notably, prosthesis positioning in two different cases (distal and proximal) has been examined in terms of coaptation area, average stress on valve leaflets as well as impact on the aortic root wall. The coaptation area is significantly affected by the positioning strategy ( ? 24%, moving from the proximal to distal) as well as the stress distribution on both the leaflets (+13.5%, from proximal to distal) and the aortic wall ( ? 22%, from proximal to distal). No remarkable variations of the stress state on the stent struts have been obtained in the two investigated cases.  相似文献   

15.
In some cases of aortic valve leaflet disease, the implant of a stentless biological prosthesis represents an excellent option for aortic valve replacement (AVR). In particular, if compared with the implant of mechanical valves, it provides a more physiological haemodynamic performance and a reduced thrombogeneticity, avoiding the use of anticoagulants. The clinical outcomes of AVR are strongly dependent on an appropriate choice of both prosthesis size and replacement technique, which is, at present, strictly related to surgeon's experience and skill. This represents the motivation for patient-specific finite element analysis able to virtually reproduce stentless valve implantation. With the aim of performing reliable patient-specific simulations, we remark that, on the one hand, it is not well established in the literature whether bioprosthetic leaflet tissue is isotropic or anisotropic; on the other hand, it is of fundamental importance to incorporate an accurate material model to realistically predict post-operative performance. Within this framework, using a novel computational methodology to simulate stentless valve implantation, we test the impact of using different material models on both the stress pattern and post-operative coaptation parameters (i.e. coaptation area, length and height). As expected, the simulation results suggest that the material properties of the valve leaflets affect significantly the post-operative prosthesis performance.  相似文献   

16.
17.
The development of the spirally thickened xylem element from a cambium initial of sycamore Acer pseudoplatanus has been traced by means of electron microscopy. The narrow elongated cambial initial undergoes considerable expansion in all dimensions. The cytoplasm at this stage is distributed in a thin skin between the cell wall and a large vacuole. No correlation has been observed between the distribution of any organelle and the pattern of the eventual thickenings. After the sites of thickening deposition have become apparent, the most conspicuous feature of the cell is the proliferation of Golgi bodies and vesicles. It is suggested that the material of the developing thickenings stems from direct apposition of the material in the Golgi vesicles. After glutaraldehyde fixation, microtubules (200 to 220 A in diameter) are seen to be sited in specific relation to the thickenings, the orientation of the tubules mirroring that of the fibrils seen in the thickenings. Possible reasons for absence of an observable pattern in the expanded but relatively undifferentiated cell are given, and the possible roles of the Golgi apparatus and microtubules in the thickening production are discussed  相似文献   

18.

Background  

Because of higher life expectancy, the number of elderly patients today with degenerative aortic diseases is on the increase. Often artificial aortic roots are needed to replace the native tissue. This surgical procedure requires re-implantation of the previous separated coronary arteries into the wall of the prosthesis. Regardless of the prosthesis type, changes in the reinsertion technique, e.g., the variation of the outlet angle of the coronary arteries, could influence the coronary blood flow. Whether the prosthesis type or the outlet angle variation significantly improves the blood circulation and lowers the risk of coronary insufficiency is still an open question. The numerical calculations presented can help to clear up these disputable questions.  相似文献   

19.
红细胞抗高血压因子舒血管作用机制的研究   总被引:7,自引:0,他引:7  
本实验研究了从Sprague-Dawley大鼠红细胞中提取的抗高血压因子(antihypertensivefactor,AHF)对苯肾上腺素引起的Wistar大鼠胸主动脉螺旋条预收缩的舒张作用。结果表明:AHF对主动脉条的舒张呈内皮与剂量依赖性。左旋硝基精氨酸与美蓝均可阻断AHF的舒血管作用,而铜锌超氧化物歧化酶对AHF的舒血管效应有促进作用。提示AHF是通过刺激内皮细胞产生一氧化氨或其类似物,从而激活血管平滑肌细胞内可溶性鸟苷酸环化酶这一途径引起血管舒张的。  相似文献   

20.
The great adaptability shown by RNA viruses is a consequence of their high mutation rates. The evolution of fitness in a severely debilitated, clonal population of the nonsegmented ribovirus vesicular stomatitis virus (VSV) has been compared under five different demographic regimes, ranging from severe serial bottleneck passages (one virion) to large population passages (105 virions or more) under similar environmental conditions (cell culture type and temperature). No matter how small the bottleneck, the fitness of the evolved populations was always higher than the fitness of the starting population; this result is clearly different from that previously reported for viruses with higher fitness. The reattainment of fitness under a regime of serial population passages showed two main characteristics: (1) the rate of adaptation was higher during early passages; and (2) a maximum fitness value was reached after a large number of passages. The maximum fitness reached by this initially debilitated clone was similar to the fitness of wild-type virus. The practical implications of these findings in the design of vaccines using attenuated viruses are also discussed.  相似文献   