首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A new method for the simultaneous detection of rotational mobility and proximity of cell surface receptors is presented based on cell-by-cell basis measurement of polarized fluorescence intensity components of the donor and acceptor of a FRET system. In addition to the FRET efficiency and the donor and acceptor concentrations, the method makes also possible the determination of the rotational characteristics and the associated fraction of the donors (FRET-fraction). The method is illustrated with flow cytometric and rFLIM measurements on donor–acceptor systems comprising fluorescently labeled whole antibodies and their Fab fragments against epitopes of the MHCI and MHCII cell surface receptors on human lymphoblast cells. Fluorescence anisotropy of donor and acceptor and FRET efficiency were measured for samples of different acceptor-to-donor concentration ratios. Acceptor anisotropy proved to be more sensitive than the donor anisotropy for sensing FRET. After determining the rotational constants of the donor-conjugated antibodies by measurements of FRET in the steady state, and by rFLIM as a reference, the associated fractions of the MHCI and MHCII molecules in their clusters were determined. Besides the flow cytometer and the wide-field rFLIM used in this study, the method can be applied also in other devices capable of dual-anisotropy detection.  相似文献   

2.
BACKGROUND: Flow cytometric fluorescence resonance energy transfer (FCET) is an efficient method to map associations between biomolecules because of its high sensitivity to changes in molecular distances in the range of 1-10 nm. However, the requirement for a dual-laser instrument and the need for a relatively high signal-to-noise system (i.e., high expression level of the molecules) pose limitations to a wide application of the method. METHODS: Antibodies conjugated to cyanines 3 and 5 (Cy3 and Cy5) were used to label membrane proteins on the cell surface. FCET measurements were made on a widely used benchtop dual-laser flow cytometer, the FACSCalibur, by using cell-by-cell analysis of energy transfer efficiency.ResultsTo increase the accuracy of FCET measurements, we applied a long wavelength donor-acceptor pair, Cy3 and Cy5, which beneficially affected the signal-to-noise ratio in comparison with the classic pair of fluorescein and rhodamine. A new algorithm for cell-by-cell correction of autofluorescence further improved the sensitivity of the technique; cell subpopulations with only slightly different FCET efficiencies could be identified. The new FCET technique was tested on various direct and indirect immunofluorescent labeling strategies. The highest FCET values could be measured when applying direct labeling on both (donor and acceptor) sides. Upon increasing the complexity of the labeling scheme by introducing secondary antibodies, we detected a decrease in the energy transfer efficiency. CONCLUSIONS: We developed a new FCET protocol by applying long wavelength excitation and detection of fluorescence and by refining autofluorescence correction. The increased accuracy of the new method makes cells with low receptor expression amenable to FCET investigation, and the new approach can be implemented easily on a commercially available dual-laser flow cytometer, such as a FACSCalibur.  相似文献   

3.
Dual-laser flow cytometric resonance energy transfer (FCET) is a statistically efficient and accurate way of determining proximity relationships for molecules of cells even under living conditions. In the framework of this algorithm, absolute fluorescence resonance energy transfer (FRET) efficiency is determined by the simultaneous measurement of donor-quenching and sensitized emission. A crucial point is the determination of the scaling factor α responsible for balancing the different sensitivities of the donor and acceptor signal channels. The determination of α is not simple, requiring preparation of special samples that are generally different from a double-labeled FRET sample, or by the use of sophisticated statistical estimation (least-squares) procedures. We present an alternative, free-from-spectral-constants approach for the determination of α and the absolute FRET efficiency, by an extension of the presented framework of the FCET algorithm with an analysis of the second moments (variances and covariances) of the detected intensity distributions. A quadratic equation for α is formulated with the intensity fluctuations, which is proved sufficiently robust to give accurate α-values on a cell-by-cell basis in a wide system of conditions using the same double-labeled sample from which the FRET efficiency itself is determined. This seemingly new approach is illustrated by FRET measurements between epitopes of the MHCI receptor on the cell surface of two cell lines, FT and LS174T. The figures show that whereas the common way of α determination fails at large dye-per-protein labeling ratios of mAbs, this presented-as-new approach has sufficient ability to give accurate results. Although introduced in a flow cytometer, the new approach can also be straightforwardly used with fluorescence microscopes.  相似文献   

4.
A method has been developed for the determination of the efficiency (E) of the fluorescence resonance energy transfer between moieties on cell surfaces by use of a computer-controlled flow cytometer capable of dual wavelength excitation. The absolute value of E may be calculated on a single-cell basis. The analysis requires the measurement of samples stained with donor and acceptor conjugated ligands alone as well as together. In model experiments HK 22 murine lymphoma cells labeled with fluorescein-conjugated concanavalin A (Con A) and/or rhodamine conjugated Con A were used to determine energy transfer histograms. Using the analytic solution to energy transfer in two dimensions, a high surface density of Con A binding sites was found that suggests that the Con A receptor sites on the cell surface are to a degree preclustered . We call this technique flow cytometric energy transfer ( FCET ).  相似文献   

5.
Relationship of donor and acceptor fluorescence anisotropies as well as efficiency of fluorescence resonance energy transfer (FRET) has been investigated in a confocal microscope in the context of FRET systems comprised of donor and acceptor-labeled MHCI and MHCII receptors on the surface of Kit-225 K6 human T-cells. The measurements have been carried out in a 2-laser, 5-signal platform where the total donor fluorescence intensity and 2 acceptor fluorescence intensities with their anisotropies – one at the donor's excitation wavelength, the other at the acceptor's excitation wavelength – have been detected. This configuration enabled the determination of FRET efficiency and correlating it with the two acceptor fluorescence anisotropies as a kind of calibration. Estimations for the FRET-enhanced donor fluorescence anisotropy, the directly excited acceptor fluorescence anisotropy, and the fluorescence anisotropy of sensitized emission have been obtained. Procedures for determining FRET by measuring only the total donor intensity and the acceptor intensity and its anisotropy, or two acceptor intensities and their anisotropies have been elaborated, the errors of which have been estimated based on the fluorescence anisotropy values obtained in the calibration with the method of flow cytometric energy transfer (FCET).The combined detection of the donor and acceptor fluorescence anisotropies enabled also the determination of the lower and upper limits of the orientation factor for FRET (κ2). An increase in range for κ2 with increasing FRET efficiency has been observed, with average κ2 values different from the dynamic random average of 2/3. These observations call for the need of κ2 determination in proximity measurements, where the donor and acceptor orientations are not predictable.An increasing range of κ2 with increasing intermolecular proximity of the MHCI and MHCII receptors has been observed. This indicates that molecular flexibility in the clusters of the MHCI and MHCII receptors reduces with increasing cluster density, i.e. a “fluidity gradient” exists in the clusters. More specifically, the local density dependent flexibility can also be taken as a direct proof for that the association of these receptors is non-random, but mediated by some type of physical interaction, a finding as a benefit of FRET detection by polarization spectroscopy.Two new quantities – the quenched donor fluorescence anisotropy and a fluorescence anisotropy analogue, the “dissymmetry index” of the polarized FRET efficiency components – have also been introduced for the characterization of the orientational dynamics of the excited state during FRET.  相似文献   

6.
Fluorescence energy homotransfer offers a powerful tool for the investigation of the state of oligomerization of cell surface receptors on a cell-by-cell basis by measuring the polarized components of fluorescence intensity of cells labeled with fluorescently stained antibodies. Here we describe homotransfer-based methods for the flow cytometric detection and analysis of hetero- and homo-associations of cell surface receptors. Homotransfer efficiencies for two- and three-body energy transfer interactions are defined and their frequency distribution curves are computed from the fluorescence anisotropy distributions of multiple-labeled cells. The fractions of receptors involved in homo-clustering is calculated based on the dependence of the fluorescence anisotropy on the surface concentration of the fluorescently stained antibodies. A homotransfer analysis of the homo- and hetero-clustering of the MHCI and MHCII glycoproteins, the cytokine receptor IL-2Ralpha, transferrin receptor and the receptor-type tyrosine phosphatase CD45 on JY B and Kit-225-K6 T cells is presented. We investigated how various factors such as the type of dye, rotational mobility of the dye and dye-targeting antibody, as well as the wavelength of the exciting light affect the homotransfer. We show that the homotransfer technique combined with the high statistical resolution of flow cytometry is an effective tool for detecting different oligomeric states of receptors by using fluorophores having restricted rotational mobility on the time scale of fluorescence.  相似文献   

7.
Fluorescent derivatives of a human MHC class I glycoprotein, HLA-A2, were reconstituted into dimyristoylphosphatidylcholine (DMPC) liposomes. Measurements of lateral diffusion of fluorescein-(Fl-) labeled HLA-A2 by fluorescence photobleaching recovery (FPR), of rotational diffusion of erythrosin-(Er-) labeled HLA-A2 by time-resolved phosphorescence anisotropy (TPA), and of molecular proximity by flow cytometric fluorescence resonance energy transfer (FCET) showed that these class I MHC molecules self-associate in liposome membranes, forming small aggregates even at low surface concentrations. The lateral diffusion coefficient (Dlat) of Fl-HLA-A2 decreases with increasing surface protein concentration over a range of lipid:protein molar ratios (L/P) between 8000:1 and 2000:1. The reduction in Dlat of HLA molecules in DMPC liposomes is found to be sensitive to time and temperature. The rotational correlation time for Er-HLA-A2 in DMPC liposomes at 30 degrees C is 87 +/- 0.8 microseconds, at least 10 times larger than that expected for an HLA monomer. There is also significant quenching of donor (Fl-HLA) fluorescence at 37 degrees C in the presence of acceptor-labeled (sulforhodamine-labeled HLA) protein indicating proximity between HLA molecules even at L/P = 4000:1. FPR and FCET measurements with another membrane glycoprotein, glycophorin, give no evidence for its self-association. HLA aggregation measured by FPR, FCET, and TPA was blocked by beta 2-microglobulin, b2m, added to the liposomes. The aggregation of HLA-A2 molecules is not an artifact of their reconstitution into liposomes. HLA aggregates, defined by FCET, were readily detected on the surface of human lymphoblastoid (JY) cells.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

8.
The physical association of HLA class I and class II Ag in the membranes of PGF and JY lymphoblastoid cell lines was studied using flow cytometric energy transfer. This technique measures the proximity of cell surface molecules in the nm range and provides a distribution histogram of the average proximity of molecules on each cell of a population. HLA Ag were labeled with mAb conjugated to fluorescein, serving as donor, or tetramethylrhodamine, serving as acceptor molecules. Significant fluorescence energy transfer was detected between various combinations of class I and class II molecules indicating that these molecules are within 10 nanometers of each other. Specifically, energy transfer was observed between class I molecules and DR, DQ, or DP class II HLA molecules. In addition, energy transfer between all combinations of DR, DQ, and DP molecules was observed. No transfer was observed among class I molecules or among DR or among DP molecules. Among DQ molecules, subpopulations transferred fluorescence energy to each other. The close contact measured between class I and class II Ag correlates with previous reports of cocapping and may reflect an immunologically significant interaction or the reported tendency of class I Ag to associate with other cell surface receptors, including growth factor receptors. The energy transfer between fluorescent antibodies to class II Ag suggests the existence of heterodimers formed from the different locus products, as well as possible quaternary surface interactions between alpha/beta complexes from separate loci.  相似文献   

9.
Investigation of protein-protein associations is important in understanding structure and function relationships in living cells. Using Förster-type resonance energy transfer between donor and acceptor labeled monoclonal antibodies we can assess the cell surface topology of membrane proteins against which the antibodies were raised. In our current work we elaborated a quantitative image microscopic technique based on the measurement of fluorescence intensities to calculate the energy transfer efficiency on a pixel-by-pixel basis. We made use of the broad excitation and emission spectrum of cellular autofluorescence for background correction of images. In addition to the reference autofluorescence images (UV background) we recorded three fluorescent images (donor, acceptor and energy transfer signal) of donor-acceptor double labeled samples, and corrected for spectral spillage of the directly excited donor and acceptor fluorescence into the energy transfer image. After careful image registration we were able to calculate the energy transfer efficiency on a pixel-by-pixel basis. In this paper, we also present a critical comparison between results obtained with this method and other approaches (photobleaching and flow cytometric energy transfer measurements).  相似文献   

10.
Dual-laser flow cytometric resonance energy transfer (FCET) is a statistically efficient and accurate way of determining proximity relationships for molecules of cells even under living conditions. In the framework of this algorithm, absolute fluorescence resonance energy transfer (FRET) efficiency is determined by the simultaneous measurement of donor-quenching and sensitized emission. A crucial point is the determination of the scaling factor α responsible for balancing the different sensitivities of the donor and acceptor signal channels. The determination of α is not simple, requiring preparation of special samples that are generally different from a double-labeled FRET sample, or by the use of sophisticated statistical estimation (least-squares) procedures. We present an alternative, free-from-spectral-constants approach for the determination of α and the absolute FRET efficiency, by an extension of the presented framework of the FCET algorithm with an analysis of the second moments (variances and covariances) of the detected intensity distributions. A quadratic equation for α is formulated with the intensity fluctuations, which is proved sufficiently robust to give accurate α-values on a cell-by-cell basis in a wide system of conditions using the same double-labeled sample from which the FRET efficiency itself is determined. This seemingly new approach is illustrated by FRET measurements between epitopes of the MHCI receptor on the cell surface of two cell lines, FT and LS174T. The figures show that whereas the common way of α determination fails at large dye-per-protein labeling ratios of mAbs, this presented-as-new approach has sufficient ability to give accurate results. Although introduced in a flow cytometer, the new approach can also be straightforwardly used with fluorescence microscopes.  相似文献   

11.
Molecules of the lectin concanavalin A have been labeled separately with the fluorescein and rhodamine chromophores and jointly bound to the surface of transformed Friend erythroleukemia cells. The two dyes constitute an ideal donor-acceptor pair for fluorescence resonance energy transfer thereby permitting the determination of the proximity relationships between bound ligand molecules and the corresponding surface receptors. The transfer efficiency at saturation (about 57%) was measured in a multiparameter flow system using laser excitation at 488 nm and detection of fluorescein and rhodamine emission intensities as well as the emission anisotropy of the rhodamine fluorescence for each cell. The degree of energy transfer was estimated from the quenching of donor emission, the sensitization of acceptor emission, and the depolarization of acceptor fluorescence. The system has been modeled according to a formalism developed by Gennis and Cantor (Biochemistry 11: 2509, 1972). We estimate the separation between the surfaces of bound lectin molecules at saturation to be 0-40 A, a range possibly characteristic for micropatches induced by ligand binding.  相似文献   

12.
A method for the determination of circulating immune complexes (CIC) was adapted for flow cytometric analysis. Human granulocytes were used to phagocytose IgG-bearing CIC of serum from systemic lupus erythematosus (SLE) patients. A method for labeling the phagocytosed CIC with FITC-conjugated anti-human IgG was developed where the granulocytes remain in suspension during fixation and labeling. The fluorescence per cell, measured with a flow cytometer, is a measure of the total amount of the phagocytosed IgG. The results indicate that a rapid and quantitative method for the detection and measurement of phagocytosed CIC is possible using the flow cytometer.  相似文献   

13.
Flow cytometric energy transfer (FCET) measurements between labeled specific sites of cell surface elements (Sz?llosi et al., Cytometry, 5:210-216, 1984) have been extended in a simplified form using a flow cytometer equipped with single excitation beam. This versatile and easily applicable method has several advantages over any nonflow cytometric (i.e., spectrofluorimetric) energy transfer measurements on cell surfaces: The labeled ligands can be applied in excess, without washing, thereby enabling the investigation of relatively labile receptor-ligand complexes. Contributions of signals from cell debris, from cell aggregates, or from nonviable cells can be avoided by gating the data collection on the light scatter signal. The heterogeneity of the cell population with respect to the proximity of the labeled binding sites can be studied. In the cases of homologous ligands or of ligands binding to the same molecule but at different epitopes, the determination of fluorescence resonance energy transfer efficiency values can be carried out on a cell-by-cell basis, offering data on intramolecular conformational changes. This modified FCET method enabled us to demonstrate the uniform density of glycoproteins, specific for Con A binding, in the plasma membrane of normal and Gross virus leukemic mouse cells of different sizes. The utility of this procedure has also been demonstrated by using the mean fluorescence intensities of the distribution curves in the calculation of the fluorescence energy transfer efficiency.  相似文献   

14.
Major histocompatibility complex (MHC) class II molecules are membrane-anchored heterodimers that present antigenic peptides to T cells. Expression of these molecules in soluble form has met limited success, presumably due to their large size, heterodimeric structure and the presence of multiple disulfide bonds. Here we have used directed evolution and yeast surface display to engineer soluble single-chain human lymphocyte antigen (HLA) class II MHC DR1 molecules without covalently attached peptides (scDR1alphabeta). Specifically, a library of mutant scDR1alphabeta molecules was generated by random mutagenesis and screened by fluorescence activated cell sorting (FACS) with DR-specific conformation-sensitive antibodies, yielding three well-expressed and properly folded scDR1alphabeta variants displayed on the yeast cell surface. Detailed analysis of these evolved variants and a few site-directed mutants generated de novo indicated three amino acid residues in the beta1 domain are important for the improved protein folding yield. Further, molecular modeling studies suggested these mutations might increase the protein folding efficiency by improving the packing of a hydrophobic core in the alpha1beta1 domain of DR1. The scDR1alphabeta mutants displayed on the yeast cell surface are remarkably stable and bind specifically to DR-specific peptide HA(306-318) with high sensitivity and rapid kinetics in flow cytometric assays. Moreover, since the expression, stability and peptide-binding properties of these mutants can be directly assayed on the yeast cell surface using immuno-fluorescence labeling and flow cytometry, time-consuming purification and refolding steps of recombinant DR1 molecules are eliminated. Therefore, these scDR1alphabeta molecules will provide a powerful technology platform for further design of DR1 molecules with improved peptide-binding specificity and affinity for therapeutic and diagnostic applications. The methods described here should be generally applicable to other class II MHC molecules and also class I MHC molecules for their functional expression, characterization and engineering.  相似文献   

15.
Microsphere-based flow cytometric detection of cholera toxin (CT) through distance-dependent fluorescence resonant energy transfer (FRET) has been developed. Simultaneous double-fluorescence changes induced by multivalent interactions between CT and fluorophore (both fluorescence donor and acceptor)-labeled ganglioside GM1 on a biomimetic membrane surface (supported bilayers of phospholipids) can be measured by a commercial flow cytometer, providing a convenient and sensitive detection method for CT. The flow cytometry-based biosensor is capable of detecting less than 10 pM CT within 30 min. The signal generation strategy coupled with flow cytometry also provides a convenient method for kinetic studies of multivalent interactions. The surface density and the ratio of donor/acceptor-labeled GM1 on the surfaces of phospholipid bilayers are optimized to achieve high sensitivity.  相似文献   

16.
Kaplan D  Smith D 《Cytometry》2000,40(1):81-85
BACKGROUND: Flow cytometric analysis is a powerful technique for the single cell assessment of cell surface expression of selected molecules. The major deficiency of flow cytometry has been its relative insensitivity. Only molecules expressed in abundance have been readily observed. METHODS: We have developed an enzymatic amplification procedure for the analysis of cell surface molecules by flow cytometry. Transformed and nontransformed cells expressing MHC class I, CD5, CD3, CD4, CD6, CD7, CD34, CD45, MHC class II, Fas ligand, and phosphatidylserine were assessed. RESULTS: Our enzymatic amplification technology increased the fluorescence signal between 10 and 100-fold for all surface molecules tested. CONCLUSIONS: Enzymatic amplification staining produces a significant enhancement in the resolving power of flow cytometric analysis of cell surface molecules. Using this technique, we have been able to detect the presence of molecules that could not be observed by the standard procedure.  相似文献   

17.
We describe practical aspects of photobleaching fluorescence energy transfer measurements on individual living cells. The method introduced by T. M. Jovin and co-workers (see, most recently, Kubitscheck et al. 1993. Biophys. J. 64:110) is based on the reduced rate of irreversible photobleaching of donor fluorophores when acceptor fluorophores are present. Measuring differences in donor photobleaching rates on cells labeled with donor only (fluorescein isothiocyanate-conjugated proteins) and with both donor and acceptor (tetramethylrhodamine-conjugated proteins) allows calculation of the fluorescence energy transfer efficiency. We assess possible methods of data analysis in light of the underlying processes of photobleaching and energy transfer and suggest optimum strategies for this purpose. Single murine B lymphocytes binding various ratios of donor and acceptor conjugates of tetravalent concanavalin A (Con A) and divalent succinyl Con A were examined for interlectin energy transfer by these methods. For Con A, a maximum transfer efficiency of 0.49 +/- 0.02 was observed. Under similar conditions flow cytometric measurements of donor quenching yielded a value of 0.54 +/- 0.03. For succinyl Con A, the maximum transfer efficiency was 0.36. To provide concrete examples of quantities arising in such energy transfer determinations, we present examples of individual cell data and kinetic analyses, population rate constant distributions, and error estimates for the various quantities involved.  相似文献   

18.
BACKGROUND: The combination of fluorescence resonance energy transfer (FRET) and flow cytometry offers a statistically firm approach to study protein associations. Fusing green fluorescent protein (GFP) to a studied protein usually does not disturb the normal function of a protein, but quantitation of FRET efficiency calculated between GFP derivatives poses a problem in flow cytometry. METHODS: We generated chimeras in which cyan fluorescent protein (CFP) was separated by amino acid linkers of different sizes from yellow fluorescent protein (YFP) and used them to calibrate the cell-by-cell flow cytometric FRET measurements carried out on two different dual-laser flow cytometers. Then, CFP-Kip1 was coexpressed in yeast cells with YFP and cyclin-dependent kinase-2 (Cdk2) and served as a positive control for FRET measurements, and CFP-Kip1 coexpressed with a random peptide fused to YFP was the negative control. RESULTS: We measured donor, direct, and sensitized acceptor fluorescence intensities and developed a novel way to calculate a factor (alpha) that characterized the fluorescence intensity of acceptor molecules relative to the same number of excited donor molecules, which is essential for quantifying FRET efficiency. This was achieved by calculating FRET efficiency in two different ways and minimizing the squared difference between the two results by changing alpha. Our method reliably detected the association of Cdk2 with its inhibitor, Kip1, whereas the nonspecific FRET efficiency between Cdk2 and a random peptide was negligible. We identified and sorted subpopulations of yeast cells showing interaction between the studied proteins. CONCLUSIONS: We have described a straightforward novel calibration method to accurately quantitate FRET efficiency between GFP derivatives in flow cytometry.  相似文献   

19.
Measurements of the anisotropy of protein fluorescence as a function of an added collisional quencher, such as acrylamide, are used to construct Perrin plots. For single tryptophan containing proteins, such plots yield an apparent rotational correlation time for the depolarization process, which, in most cases, is approximately the value expected for Brownian rotation of the entire protein. Apparent limiting fluorescence anisotropy values, which range from 0.20 to 0.32 for the proteins studied, are also obtained from the Perrin plots. The lower values for the limiting anisotropy found for some proteins are interpreted as indicating the existence of relatively rapid, limited (within a cone of angle 0 degrees--30 degrees) motion of the tryptophan side chains that is independent of the overall rotation of the protein. Examples of the use of this fluorescence technique to study protein conformational changes are presented, including the monomer in equilibrium dimer equilibrium of beta-lactoglobulin, the monomer in equilibrium tetramer equilibrium of melittin, the N in equilibrium F transition of human serum albumin, and the induced change in the conformation of cod parvalbumin caused by the removal of Ca+2. Because multitryptophan-containing proteins have certain tryptophans that are accessible to solute quencher and others that are inaccessible, this method can be used to determine the steady state anisotropy of each class of tryptophan residues.  相似文献   

20.
Celiac disease (CD) is an immune-mediated disorder affecting genetically predisposed subjects. It is caused by the ingestion of wheat gluten and related prolamins. A final diagnosis for this disease can be obtained by examination of jejunal biopsies. Nevertheless, different analytical approaches have been established to detect the presence of anti-tissue transglutaminase antibodies that represent a serological hallmark of the disease. In this work, we explored a new method for the diagnosis of CD based on the detection of serum anti-transglutaminase antibodies by resonance energy transfer (RET) between donor molecules and acceptor molecules. In particular, we labeled the liver transglutaminase (tTG) enzyme from guinea pig and the rabbit anti-tTG antibodies with a couple of fluorescence probes that are able to make RET if they are located within with Förster distance. We labeled tTG with the fluorescence probe DyLight 594 as donor and the anti-tTG antibodies with the fluorescence probe DyLight 649 as acceptor. However, due to the large size of the formed complex (tTG/anti-tTG), and consequently to the low efficiency energy transfer process between the donor–acceptor molecules, we explored a new experimental approach that allows us to extend the utilizable range of RET between donor:acceptor pairs by using one single molecule as donor and multiple molecules as energy acceptors, instead of using a single acceptor molecule as usually occurs in RET experiments. The obtained results clearly show that the use of one donor and multiacceptor strategy enables for a simple and rapid detection of serum anti-transglutaminase antibodies. In addition, our results point out that it is possible to consider this approach as a new method for a wide variety of analytical assays.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏