首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Contactless atmospheric pressure ionization (C-API) method has been recently developed for mass spectrometric analysis. A tapered capillary is used as both the sampling tube and spray emitter in C-API. No electric contact is required on the capillary tip during C-API mass spectrometric analysis. The simple design of the ionization method enables the automation of the C-API sampling system. In this study, we propose an automatic C-API sampling system consisting of a capillary (∼1 cm), an aluminium sample holder, and a movable XY stage for the mass spectrometric analysis of organics and biomolecules. The aluminium sample holder is controlled by the movable XY stage. The outlet of the C-API capillary is placed in front of the orifice of a mass spectrometer, whereas the sample well on the sample holder is moved underneath the capillary inlet. The sample droplet on the well can be readily infused into the C-API capillary through capillary action. When the sample solution reaches the capillary outlet, the sample spray is readily formed in the proximity of the mass spectrometer applied with a high electric field. The gas phase ions generated from the spray can be readily monitored by the mass spectrometer. We demonstrate that six samples can be analyzed in sequence within 3.5 min using this automatic C-API MS setup. Furthermore, the well containing the rinsing solvent is alternately arranged between the sample wells. Therefore, the C-API capillary could be readily flushed between runs. No carryover problems are observed during the analyses. The sample volume required for the C-API MS analysis is minimal, with less than 1 nL of the sample solution being sufficient for analysis. The feasibility of using this setup for quantitative analysis is also demonstrated.  相似文献   

2.
High-field asymmetric waveform ion mobility spectrometry (FAIMS) is an atmospheric pressure ion mobility technique that can be used to reduce sample complexity and increase dynamic range in tandem mass spectrometry experiments. FAIMS fractionates ions in the gas-phase according to characteristic differences in mobilities in electric fields of different strengths. Undesired ion species such as solvated clusters and singly charged chemical background ions can be prevented from reaching the mass analyzer, thus decreasing chemical noise. To date, there has been limited success using the commercially available Thermo Fisher FAIMS device with both standard ESI and nanoLC-MS. We have modified a Thermo Fisher electrospray source to accommodate a fused silica pulled tip capillary column for nanospray ionization, which will enable standard laboratories access to FAIMS technology. Our modified source allows easily obtainable stable spray at flow rates of 300 nL/min when coupled with FAIMS. The modified electrospray source allows the use of sheath gas, which provides a fivefold increase in signal obtained when nanoLC is coupled to FAIMS. In this work, nanoLC-FAIMS-MS and nanoLC-MS were compared by analyzing a tryptic digest of a 1:1 mixture of SILAC-labeled haploid and diploid yeast to demonstrate the performance of nanoLC-FAIMS-MS, at different compensation voltages, for post-column fractionation of complex protein digests. The effective dynamic range more than doubled when FAIMS was used. In total, 10,377 unique stripped peptides and 1649 unique proteins with SILAC ratios were identified from the combined nanoLC-FAIMS-MS experiments, compared with 6908 unique stripped peptides and 1003 unique proteins with SILAC ratios identified from the combined nanoLC-MS experiments. This work demonstrates how a commercially available FAIMS device can be combined with nanoLC to improve proteome coverage in shotgun and targeted type proteomics experiments.  相似文献   

3.
Analysis of glycans via a porous graphitized carbon liquid chromatography (PGC-LC) coupled with electrospray ionization (tandem) mass spectrometry (ESI-MS(/MS)) is a powerful analytical method in the field of glycomics. Isobaric glycan structures can be identified reliably with the help of PGC-LC separation and subsequent identification by ESI-MS(/MS) in negative ion mode. In an effort to adapt PGC-LC-ESI-MS(/MS) to the nano-scale operation, spray instability along the nano-PGC-LC gradient was repeatedly observed on an LTQ Orbitrap Elite mass spectrometer equipped with a standard nano-electrospray ionization source. A stable electrospray was achieved with the implementation of a post-column make-up flow (PCMF). Thereby, acetonitrile was used to supplement the eluate from the nano-PGC-LC column. The improved spray stability enhanced detection and resolution of glycans during the analysis. This was in particular the case for smaller O-glycans which elute early in the high aqueous content regime of the nano-PGC-LC elution gradient. This study introduces PCMF as an easy-to-use instrumental adaptation to significantly improve spray stability in negative ion mode nano-PGC-LC-ESI-MS(/MS)-based analysis of glycans.  相似文献   

4.
A mass spectrometry-based method was developed for selective detection of FP-biotinylated peptides in complex mixtures. Mixtures of peptides, at the low-picomole level, were analyzed by liquid chromatography and positive ion, nanospray, triple quadrupole, linear ion trap mass spectrometry. Peptides were fragmented by collision-activated dissociation in the mass spectrometer. The free FP-biotin and peptides containing FP-biotinylated serine or FP-biotinylated tyrosine yielded characteristic fragment ions at 227, 312, and 329 m/z. FP-biotinylated serine yielded an additional characteristic fragment ion at 591 m/z. Chromatographic peaks containing FP-biotinylated peptides were indicated by these diagnostic ions. Data illustrating the selectivity of the approach are presented for tryptic digests of FP-biotinylated trypsin and FP-biotinylated serum albumin. A 16-residue peptide from bovine trypsin was biotinylated on the active site serine. A 3-residue peptide from bovine albumin, YTR, was biotinylated on Tyr410. This latter result confirms that the organophosphorus binding site of albumin is a tyrosine. This method can be used to search for new biomarkers of organophosphorus agent exposure.  相似文献   

5.
6.
The objective of this study was to investigate the influence of processing parameters on the morphology, porosity, and crystallinity of polymeric polyethylene glycol (PEG) microparticles by spray freezing into liquid (SFL), a new particle engineering technology. Processing parameters investigated were the viscosity and flow rate of the polymer solution, nozzle diameter, spray time, pressure, temperature, and flow rate of the cryogenic liquid. By varying the processing parameters and feed composition, atomization and heat transfer mechanisms were modified resulting in particles of different size distribution, shape, morphology, density, porosity, and crystallinity. Median particle diameter (M50) varied from 25 μm to 600 μm. Particle shape was spherical or elongated with highly irregular surfaces. Granule density was between 0.5 and 1.5 g/mL. In addition to producing particles of pure polymer, drug particles were encapsulted in polymeric microparticles. The encapsulation efficiency of albuterol sulfate was 96.0% with a drug loading of 2.4%, indicating that SFL is useful for producing polymeric microparticles for drug delivery applications. It was determined that the physicochemical characteristics of model polymeric microparticles composed of PEG could be modified for use as a drug delivery carrier.  相似文献   

7.
Feng S  Pan C  Jiang X  Xu S  Zhou H  Ye M  Zou H 《Proteomics》2007,7(3):351-360
Immobilized metal affinity chromatography (IMAC) is a commonly used technique for phosphoproteome analysis due to its high affinity for adsorption of phosphopeptides. Miniaturization of IMAC column is essential for the analysis of a small amount of sample. Nanoscale IMAC column was prepared by chemical modification of silica monolith with iminodiacetic acid (IDA) followed by the immobilization of Fe3+ ion inside the capillary. It was demonstrated that Fe3+-IDA silica monolithic IMAC capillary column could specifically capture the phosphopeptides from tryptic digest of alpha-casein with analysis by MALDI-TOF MS. The silica monolithic IMAC capillary column was manually coupled with nanoflow RPLC/nanospray ESI mass spectrometer (muRPLC-nanoESI MS) for phosphoproteome analysis. The system was validated by analysis of standard phosphoproteins and then it was applied to the analysis of protein phosphorylation in mouse liver lysate. Besides MS/MS spectra, MS/MS/MS spectra were also collected for neutral loss peak. After database search and manual validation with conservative criteria, 29 singly phosphorylated peptides were identified by analyzing a tryptic digest of only 12 mug mouse liver lysate. The results demonstrated that the silica monolithic IMAC capillary column coupled with muRPLC-nanoESI MS was very suitable for the phosphoproteome analysis of minute sample.  相似文献   

8.
An in situ sterilizable plug-in membrane inlet mass spectrometer for monitoring dissolved gases and volatiles in fermentors was constructed and tested. The design ensured a minimal distance to be traveled by analyte molecules from the bulk of the fermentation broth to the ionization chamber of the mass spectrometer. Apart from the specific cross talk due to overlapping mass peaks from different compounds, we found that carbon dioxide interfered unspecifically with all the mass peaks of other substances, changing them by the same factor. The interference changed slowly with time and could be positive or negative depending on the history of the mass spectrometer. Also, the general sensitivity of the instrument changed slowly with time. These effects can be neglected or corrected for empirically in short-term measurements. When the fermentor was aerated with a three-component gas mixture including carbon dioxide, a rapid change in the partial pressure of carbon dioxide in the gas mixture gave rise to a transient in the signal of a gas whose partial pressure was kept constant. This effect revealed a transient change in the composition of the gas mixture in the bubbles caused by net import or export of carbon dioxide during equilibration with the new gas mixture. An experimental method to determine the effective partial pressures of gases in the bubbles during steady-state transport of carbon dioxide was designed. The plug-in membrane inlet mass spectrometer was tried as a probe for oxygen and ethanol in an oxystatic culture of the yeast Pichia stipitis. We found that it was possible to keep a steady-state concentration of as little as 0.5 muM throughout the lifetime of the culture. (c) 1997 John Wiley & Sons, Inc. Biotechnol Bioeng 54: 535-542, 1997.  相似文献   

9.
10.
A sensitive and selective LC-MS-MS method for the isolation and quantification of alpha-methyltyrosine (AMT) from human plasma is described. The method employs a simple protein precipitation using zinc sulfate and sodium hydroxide. This precipitation procedure produced samples with high aqueous content that could be directly injected into a LC-MS-MS system without compromising reverse-phase chromatographic performance. Chromatographic separation was performed on a MetaChem MonoChrom C(18) column (2.0 mm x 50 mm; 5 microm) at a flow rate of 1 mL/min. Compounds were eluted using a gradient mixture of water-acetic acid (100:0.1, v/v) and acetonitrile-acetic acid (100:0.1, v/v). The structural analog alpha-hydroxymethyltyrosine was used as the internal standard. Mass spectrometric detection was carried out with a triple quadrupole mass spectrometer. The method was validated and used to determine human plasma AMT concentrations, and has been implemented to derive pharmacokinetic parameters.  相似文献   

11.
A new and convenient pyrolysis mass spectrometric approach for monitoring solid phase phosphate triester synthesis of oligodeoxyribonucleotides in 5'-3' direction has been developed. The base-typical fragment ions produced by pyrolysis at 280 degrees C of the polymer-bound oligonucleotide triesters in the mass spectrometer permit the analytical monitoring of DNA chain growth, using simple mathematical operations. The base composition can be determined directly from the polymer. In addition, minor nucleosides can easily be detected.  相似文献   

12.
Mutation in DJ-1 gene is the cause of autosomal recessive Parkinson's disease, however, its physiological function remains unclear. The isoelectric point of DJ-1 shows an acidic shift after cells are treated with hydrogen peroxide. This suggests that DJ-1 is modified in response to oxidative stress. Here we report the structural characterization of an acidic isoform of DJ-1 using a proteomic approach with nanospray interface liquid chromatography-electrospray ionization/linear ion trap mass spectrometer. When human umbilical vein endothelial cells were exposed to hydrogen peroxide, all three cysteines in DJ-1 were oxidized to cysteine sulphonic acid. Although a small part of the Cys-46 and Cys-53 were oxidized, Cys-106 was oxidized completely at any hydrogen peroxide concentration used here. These results suggest that Cys-106 is the most sensitive among three cysteine residues to oxidative stress, and that DJ-1 function is regulated, in terms of the intracellular redox state, by oxidation of Cys-106.  相似文献   

13.
We have demonstrated the feasibility of using a compact dedicated mass spectrometer to monitor end-tidal xenon concentration in human subjects during stable xenon computerized tomography measurements of regional cerebral blood flow. End-tidal carbon dioxide concentration is monitored simultaneously and noninvasively without degrading the dynamic response to xenon. For clinical regional cerebral blood flow studies we employed a Nuclide 3-60-G Sectorr mass spectrometer with a 3 in radius, 60 degrees magnetic sector and a variable (0-5000 V) ion accelerating potential. The required high vacuum (10(-7) Torr) was achieved and maintained by means of a turbomolecular pump. A needlemetering valve was incorporated into an anesthesia mask connector, and exhaled gases were transported to the mass spectrometer via a 6 ft length of Teflon tubing (1/16 in i.d.). Molecular flow conditions between the sample and analysis chambers were provided by use of a gold foil leak (0.0005 in. hole). At an inlet pressure of 400 m Torr (achieved by means of the needle valve), the inlet system was characterized by a gas transport lag-time of 1.3 s and a rise-time constant of 85 ms. Xenon (doubly charged ion: m/z 68) and carbon dioxide (doubly charged ion: m/z 22) were monitored alternately at 75 ms intervals. Our experience with mass spectrometry has demonstrated the feasibility of using a compact dedicated instrument for accurately and non-invasively monitoring end-tidal xenon concentration in a clinical setting.  相似文献   

14.
An HPLC system incorporating a packed capillary C18 column has been utilized for high sensitivity peptide mapping and preparative collection for protein sequencing. This system combined with a Frit-FAB mass spectrometer interface also provides the ability to obtain molecular ions for peptides of enzymatically digested proteins in the time it takes to obtain an HPLC chromatogram. The low flow rates permit introduction of the entire column effluent into the mass spectrometer. Detection limits of 0.5-5 pmol are routine. Proteolytic digests of recombinant human methionyl growth hormone and protein carboxyl methyltransferase have been used to demonstrate the HPLC and mass spectrometer performance.  相似文献   

15.
Several neuropeptide FF (NPFF)-related peptides, known as modulators of the opioid system, have been previously characterized in bovine and rodent brain. Reverse-phase high pressure liquid chromatography (HPLC) fractions of a human with normal pressure hydrocephalus cerebrospinal fluid (CSF), co-migrating with NPFF-related synthetic peptides, were characterized by capillary HPLC coupled on-line to nanospray ion trap tandem mass spectrometry. Two peptides present in the pro-NPFF(A) precursor, NPAF (AGEGLNSQFWSLAAPQRF-NH2) and NPSF (SLAAPQRF-NH2), were identified. The monitoring of NPFF-related peptides in human CSF can be helpful to understand their roles in pain sensitivity.  相似文献   

16.
The validation of a liquid chromatography-tandem mass spectrometry (LC-MS-MS) method for the determination of the selective cyclooxygenase-2 inhibitor etoricoxib in human plasma with phenazone as internal standard is described. The plasma samples were extracted by solid-phase extraction using polymer-based cartridges. Chromatography was carried out on a short, narrow bore RP C(18) column (30x2 mm). Detection was achieved by a Sciex API 3000 triple quadrupole mass spectrometer equipped with a turbo ion spray source working in positive ion mode. The respective mass transitions used for quantification of etoricoxib and phenazone were m/z 359.2-->280.2 and m/z 189.0-->104.1. The analytical method was validated over the concentration range 0.2-200 ng/ml. The limit of quantification was 0.2 ng/ml. The method is applicable to pharmacokinetic studies in humans.  相似文献   

17.
An amorphous phase produced by micronization up to the molecular or colloidal level of a poorly soluble drug having low lipophilicity can distinctly enhance its solubility characteristics. However, though dispersing the molten mass of a poorly water-soluble drug within polymeric matrix has been found to be most effective in formation of molecular dispersions, the drug molecules which melt at high temperature also accompanied by decomposition, such as acetazolamide, are difficult to formulate as molecular dispersions. Hence, a method is proposed to obtain molecular dispersions of acetazolamide with poloxamer-237 by spray congealing under optimal heat treatment. Uniform molecular and/or colloidal dispersions of the drug were achieved with instantaneous solvent evaporation by mixing a drug solution with molten mass of the plasticizer matrix. Immobilization of dispersed drug molecules was effected subsequently through rapid solidification by spray congealing. Initial characterization of 1:1, 1:1.5, and 1:2 ratios of solid dispersions and devitrification study of an optimized (1:2) ratio ensured efficacy of the proposed method in formation of physically stabilized amorphous systems without thermal degradation and hence resulted in more than ninefold rise in solubility and more than 90% dissolution within initial 10 min. With 1:2 ratio, molecular dispersions could be achieved by initial solvent evaporation stage, which when subjected to spray congealing produced physically stable amorphous systems, without signs of thermal degradation. This study also proposes an opportunity for selection of those polymers with which the drug is immiscible in their fluid state, yet obtaining molecular dispersions.KEY WORDS: low molecular lipophilicity, melt with decomposition, rapid solidification, solid solutions  相似文献   

18.
Novel spray reactors are described that employ immobilized biocatalyst (carbonic anhydrase), enabling concentration and solubilization of emitted CO(2) by allowing catalytic contact with water spray. The reactors were fed with simulated emission gas. The performance of the reactors was investigated with respect to operation variable: emission flow rate; gas composition in the emission stream; water flow rate; area-to-volume ratio of immobilized reactor core; and the enzyme load within the core. The reactors were also investigated for pressure drop and extractability of CO(2) from the emission with single vs. multiple reactors (of combined equal volume). The biotechnological process of solubilization and concentration of CO(2) from emission exhausts or streams occurring in the spray reactors could be coupled for further biochemical/chemical conversion of the concentrated CO(2).  相似文献   

19.
NanoMate robot was coupled to a high-capacity ion trap (HCT) mass spectrometer to create a system merging automatic chip-based electrospray ionization (ESI) infusion, ultrafast ion detection, and multistage sequencing at superior sensitivity. The interface between the NanoMate and HCT mass spectrometer consists of an in-laboratory constructed mounting device that allows adjustment of the robot position with respect to the mass spectrometer inlet. The coupling was optimized for ganglioside (GG) high-throughput analysis in the negative ion mode and was implemented in clinical glycolipidomics for identification and structural characterization of anencephaly-associated species. By NanoMate HCT mass spectrometry (MS), data corroborating significant differences in GG expression in anencephalic versus age-matched normal brain tissue were collected. The feasibility of chip-based nanoESI HCT multistage collision-induced dissociation (CID MSn) for polysialylated GG fragmentation and isomer discrimination was tested on a GT1 (d18:1/18:0) anencephaly-associated structure. MS2-MS4 obtained by accumulating scans at variable fragmentation amplitudes gave rise to the first fragmentation patterns from which the presence of GT1b structural isomer could be determined unequivocally without the need for supplementary investigation by any other analytical or biochemical methods.  相似文献   

20.
A sensitive method for the determination of carbamazepine and carbamazepine 10,11-epoxide in plasma is described, using high-performance liquid chromatographic separation with tandem mass spectrometry. Samples were purified using liquid-liquid extraction and separated on a Phenomenex Luna C18 5 microm. 150 x 2 mm column with a mobile phase consisting of acetonitrile, methanol and formic acid (0.1%) (10:70:20, v/v). Detection was performed by a Micromass Quattro Ultima mass spectrometer in the MRM mode (LC-MS-MS) using electro spray ionisation (ESI+), monitoring the transition of the protonated molecular ion for carbamazepine at m/z 237.05 and carbamazepine 10,11-epoxide at m/z 253.09 to the predominant ions of m/z 194.09 and 180.04, respectively. The mean recovery was 95% for carbamazepine and 101% for carbamazepine 10,11-epoxide, with a lower limit of quantification of 0.722 ng/ml for carbamazepine and 5.15 ng/ml for carbamazepine 10,11-epoxide, when using 0.5 ml plasma. This high-throughput method was used to quantify 230 samples per day, and is sufficiently sensitive to be employed in pharmacokinetic studies.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏