首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Motion artifacts of in vivo imaging, due to rapid respiration rate and respiration displacements of the mice while free-breathing, is a major challenge in micro computed tomography(micro-CT). The respiratory gating is often served for either projective images acquisition or per projection qualification, so as to eliminate the artifacts brought by in vivo motion. In this paper, we propose a novel respiratory gating method, which firstly divides one rotation cycle into a number of segments, and extracts the respiratory signal from the projective image series of current segment by the value of the epipolar consistency conditions (ECC), then in terms of the measured average respiratory period, sets next segment’s start-up time and rotation speed of the gantry for respiratory phase synchronization, and so on so forth. The gating procedure is through the whole projections of three cycles, only one among three projections at each angle is qualified by their phase value and is retained for future use for tomographic image reconstruction. In practical experiment, the ECC based gating method and the conventional hardware gating method are employed on micro CT imaging of C57BL/6 mice respectively. The result shows that, compared with the hardware based one, the proposed method not only achieve much better consistency in the projection images, but also suppresses the streak artifacts more effectively on the different parts like the breast, abdomen and head of in vivo mice.  相似文献   

2.
Considering the high cost of dedicated small-animal positron emission tomography/computed tomography (PET/CT), an acceptable alternative in many situations might be clinical PET/CT. However, spatial resolution and image quality are of concern. The utility of clinical PET/CT for small-animal research and image quality improvements from super-resolution (spatial subsampling) were investigated. National Electrical Manufacturers Association (NEMA) NU 4 phantom and mouse data were acquired with a clinical PET/CT scanner, as both conventional static and stepped scans. Static scans were reconstructed with and without point spread function (PSF) modeling. Stepped images were postprocessed with iterative deconvolution to produce super-resolution images. Image quality was markedly improved using the super-resolution technique, avoiding certain artifacts produced by PSF modeling. The 2 mm rod of the NU 4 phantom was visualized with high contrast, and the major structures of the mouse were well resolved. Although not a perfect substitute for a state-of-the-art small-animal PET/CT scanner, a clinical PET/CT scanner with super-resolution produces acceptable small-animal image quality for many preclinical research studies.  相似文献   

3.
Low-dose protocols for respiratory gating in cardiothoracic small-animal imaging lead to streak artifacts in the images reconstructed with a Feldkamp-Davis-Kress (FDK) method. We propose a novel prior- and motion-based reconstruction (PRIMOR) method, which improves prior-based reconstruction (PBR) by adding a penalty function that includes a model of motion. The prior image is generated as the average of all the respiratory gates, reconstructed with FDK. Motion between respiratory gates is estimated using a nonrigid registration method based on hierarchical B-splines. We compare PRIMOR with an equivalent PBR method without motion estimation using as reference the reconstruction of high dose data. From these data acquired with a micro-CT scanner, different scenarios were simulated by changing photon flux and number of projections. Methods were evaluated in terms of contrast-to-noise-ratio (CNR), mean square error (MSE), streak artefact indicator (SAI), solution error norm (SEN), and correction of respiratory motion. Also, to evaluate the effect of each method on lung studies quantification, we have computed the Jaccard similarity index of the mask obtained from segmenting each image as compared to those obtained from the high dose reconstruction. Both iterative methods greatly improved FDK reconstruction in all cases. PBR was prone to streak artifacts and presented blurring effects in bone and lung tissues when using both a low number of projections and low dose. Adopting PBR as a reference, PRIMOR increased CNR up to 33% and decreased MSE, SAI and SEN up to 20%, 4% and 13%, respectively. PRIMOR also presented better compensation for respiratory motion and higher Jaccard similarity index. In conclusion, the new method proposed for low-dose respiratory gating in small-animal scanners shows an improvement in image quality and allows a reduction of dose or a reduction of the number of projections between two and three times with respect to previous PBR approaches.  相似文献   

4.
This article describes the technical principles and clinical applications of dual source CT. A dual source CT (DSCT) is a CT system with two x-ray tubes and two detectors at an angle of approximately 90°. Both measurement systems acquire CT scan data simultaneously at the same anatomical level of the patient (same z-position). DSCT provides temporal resolution of approximately a quarter of the gantry rotation time for cardiac, cardio-thoracic and pediatric imaging. Successful imaging of the heart and the coronary arteries at high and variable heart rates has been demonstrated. DSCT systems can be operated at twice the spiral pitch of single source CT systems (up to pitch 3.2). The resulting high table speed is beneficial for pediatric applications and fast CT angiographic scans, e. g. of the aorta or the extremities. Operating both X-ray tubes at different tube potential (kV) enables the acquisition of dual energy data and the corresponding applications such as monoenergetic imaging and computation of material maps. Spectral separation can be improved by different filtration of the X-ray beams of both X-ray tubes. As a downside, DSCT systems have to cope with some challenges, among them the limited size of the second measurement system, and cross-scattered radiation.  相似文献   

5.
In industrial computed tomography (CT), the mismatch between the X-ray energy and the effective thickness makes it difficult to ensure the integrity of projection data using the traditional scanning model, because of the limitations of the object’s complex structure. So, we have developed a CT imaging method that is based on a spherical trajectory. Considering an unrestrained trajectory for iterative reconstruction, an iterative algorithm can be used to realise the CT reconstruction of a spherical trajectory for complete projection data only. Also, an inclined circle trajectory is used as an example of a spherical trajectory to illustrate the accuracy and feasibility of this new scanning method. The simulation results indicate that the new method produces superior results for a larger cone-beam angle, a limited angle and tabular objects compared with traditional circle trajectory scanning.  相似文献   

6.
PurposeThe aim of this work was the commissioning of delivery procedures for the treatment of moving targets in scanning pencil beam hadrontherapy.MethodsEBT3 films fixed to the Anzai Respiratory Phantom were exposed to carbon ion scanned homogeneous fields (E = 332 MeV/u). To evaluate the interplay effect, field size and flatness for 3 different scenarios were compared to static condition: gated irradiation or repainting alone and combination of both. Respiratory signal was provided by Anzai pressure sensor or optical tracking system (OTS). End-exhale phase and 1 s gating window were chosen (2.5 mm residual motion). Dose measurements were performed using a PinPoint ionization chamber inserted into the Brainlab ET Gating Phantom. A sub-set of tests was also performed using proton beams.ResultsThe combination of gating technique and repainting (N = 5) showed excellent results (6.1% vs 4.3% flatness, identical field size and dose deviation within 1.3%). Treatment delivery time was acceptable. Dose homogeneity for gated irradiation alone was poor. Both Anzai sensor and OTS appeared suitable for providing respiratory signal. Comparisons between protons and carbon ions showed that larger beam spot sizes represent more favorable condition for minimizing motion effect.ConclusionResults of measurements performed on different phantoms showed that the combination of gating and layered repainting is suitable to treat moving targets using scanning ion beams. Abdominal compression using thermoplastic masks, together with multi-field planning approach and multi-fractionation, have also been assessed as additional strategies to mitigate the effect of patient respiration in the clinical practice.  相似文献   

7.
Innovations in CT have been impressive among imaging and medical technologies in both the hardware and software domain. The range and speed of CT scanning improved from the introduction of multidetector-row CT scanners with wide-array detectors and faster gantry rotation speeds. To tackle concerns over rising radiation doses from its increasing use and to improve image quality, CT reconstruction techniques evolved from filtered back projection to commercial release of iterative reconstruction techniques, and recently, of deep learning (DL)-based image reconstruction. These newer reconstruction techniques enable improved or retained image quality versus filtered back projection at lower radiation doses. DL can aid in image reconstruction with training data without total reliance on the physical model of the imaging process, unique artifacts of PCD-CT due to charge sharing, K-escape, fluorescence x-ray emission, and pulse pileups can be handled in the data-driven fashion. With sufficiently reconstructed images, a well-designed network can be trained to upgrade image quality over a practical/clinical threshold or define new/killer applications. Besides, the much smaller detector pixel for PCD-CT can lead to huge computational costs with traditional model-based iterative reconstruction methods whereas deep networks can be much faster with training and validation. In this review, we present techniques, applications, uses, and limitations of deep learning-based image reconstruction methods in CT.  相似文献   

8.
Gating currents from voltage-sensitive channels are generally attributed to the translocation or redistribution of ionic charge associated with the channel molecule. Such charge moves in the direction of the applied field to produce a decreasing current in the external circuit. An early rising phase for the gating current is observed for a number of channel systems and might be either some special kinetic redistribution of charge or an experimental artifact. A model that produces net charge in the channel through sequential molecular dissociation of a charged channel segment gives a rising phase for the gating current. Translocation of the charged segment produces the decay phase for a biphasic gating current. This kinetic molecular explanation constitutes a physical explanation for the biphasic gating currents that is consistent with present views of channel structure.  相似文献   

9.
Ligand binding at the extracellular domain of pentameric ligand-gated ion channels initiates a relay of conformational changes that culminates at the gate within the transmembrane domain. The interface between the two domains is a key structural entity that governs gating. Molecular events in signal transduction at the interface are poorly defined because of its intrinsically dynamic nature combined with functional modulation by membrane lipid and water vestibules. Here we used electron paramagnetic resonance spectroscopy to delineate protein motions underlying Gloeobacter violaceus ligand-gated ion channel gating in a membrane environment and report the interface conformation in the closed and the desensitized states. Extensive intrasubunit interactions were observed in the closed state that are weakened upon desensitization and replaced by newer intersubunit contacts. Gating involves major rearrangements of the interfacial loops, accompanied by reorganization of the protein-lipid-water interface. These structural changes may serve as targets for modulation of gating by lipids, alcohols, and amphipathic drug molecules.  相似文献   

10.
PurposeThis paper describes the hardware and software characteristics of a 3D optical scanner (P3DS) developed in-house. The P3DS consists of an LED light source, diffuse screen, step motor, CCD camera, and scanner management software with 3D reconstructed software.Materials and methodWe performed optical simulation, 2D and 3D reconstruction image testing, and pre-clinical testing for the P3DS. We developed the optical scanner with three key characteristics in mind. First, we developed a continuous scanning method to expand possible clinical applications. Second, we manufactured a collimator to improve image quality by reducing scattering from the light source. Third, we developed an optical scanner with changeable camera positioning to enable acquisition of optimal images according to the size of the gel dosimeter.ResultsWe confirmed ray-tracing in P3DS with optic simulation and found that 2D projection and 3D reconstructed images were qualitatively similar to the phantom images. For pre-clinical tests, the dose distribution and profile showed good agreement among RTP, optical CT, and external beam radiotherapy film data for the axial and coronal views. The P3DS has shown that it can scan and reconstruct for evaluation of the gel dosimeter within 1 min. We confirmed that the P3DS system is a useful tool for the measurement of 3D dose distributions for 3D radiation therapy QA. Further experiments are needed to investigate quantitative analysis for 3D dose distribution.  相似文献   

11.
Histological subtypes of lymphomas are important because FDG uptake is much greater in aggressive than in indolent lymphomas and this, results in lower sensitivity of PET for the staging of indolent lymphomas. Staging is especially useful when treatment is changed according to staging. Staging with imaging methods has traditionally been performed using a CT scanner and has been based on the detection of nodal enlargement, an increased number of small nodes and in the presence of extranodal masses. However, CT is limited by its poor sensitivity in the detection of extranodal sites of involvement, in the identification of tumour involvement of normal size lymph nodes and in the differentiation between malignant and inflammatory enlarged lymph nodes. The uptake of FDG detected with PET images reflects metabolic activity rather than the size of the tissue masses, localizing tumoral activity in enlarged and in normal size lymph nodes. In the literature review that compares PET with CT, PET usually indicates more lesions than CT would and PET improves sensitivity without losing specificity. However, the majority of studies report that PET, improves the staging in a relatively limited number of patients (10-20%) and may change treatment in less than 10% of patients. Diagnostic accuracy of PET may improve with the use of hybrid PET/CT systems that combine metabolic and morphological imaging, in the same scanner and without moving the patient. This is a promising technique that will overcome the limitations of both modalities and may enhance diagnostic accuracy in lymphoma patients. This hybrid equipment allows the use of PET/CT with contrast-enhanced full dose CT (a diagnostic CT) instead of carrying out PET and CT on different days.  相似文献   

12.
Associated with the opening and closing of the sodium channels of nerve membrane is a small component of capacitative current, the gating current. After termination of a depolarizing step the gating current and sodium current decay with similar time courses. Both currents decay more rapidly at relatively negative membrane voltages than at positive ones. The gating current that flows during a depolarizing step is diminished by a pre-pulse that inactivates the sodium permeability. A pre-pulse has no effect after inactivation has been destroyed by internal perfusion with the proteolytic enzyme pronase. Gating charge (considered as positive charge) moves outward during a positive voltage step, with voltage dependent kinetics. The time constant of the outward gating current is a maximum at about minus 10 mV, and has a smaller value at voltages either more positive or negative than this value.  相似文献   

13.
Advances in intra-operative imaging and the development of new minimally invasive techniques are having an ever greater impact on modern surgery. Mobile CT scanners in the operating room is a new technique that permits image-guided surgery, and helps minimize postoperative complications. We report on our initial experience with intraoperative CT scanning during surgery on patients suffering lateral midface trauma. A mobile CT unit, the Tomoscan M (Philips, Utrecht, Netherlands) set up in the operating room, was evaluated in 6 patients with zygomatic bone fractures. The patients were placed on the CT scanner table, which is detachable from the gantry. The unit is powered by batteries charged from an ordinary ring mains supply via a conventional plug. The CT images obtained were of good quality in all cases. No technical problems were observed during surgery. Using repeat CT scans, the procedure also permits accurate intraoperative monitoring of the anatomical repositioning of the bone fragments, and accurate implantation. No intraoperative or early postoperative complications were observed. This new technical aid ensures highly accurate reduction of the bone fragments, and minimizes the need for reoperation. High-quality intraoperative imaging with surgical navigation increase surgical outcome, and expand the spectrum of minimally invasive surgery.  相似文献   

14.
At the Italian National Centre for Oncologic Hadrontherapy (CNAO) patients with upper-abdominal tumours are being treated with carbon ion therapy, adopting the respiratory gating technique in combination with layered rescanning and abdominal compression to mitigate organ motion. Since online imaging of the irradiated volume is not feasible, this study proposes a modelling approach for the estimation of residual motion of the target within the gating window. The model extracts a priori respiratory motion information from the planning 4DCT using deformable image registration (DIR), then combines such information with the external surrogate signal recorded during dose delivery. This provides estimation of a CT volume corresponding to any given respiratory phase measured during treatment. The method was applied for the retrospective estimation of tumour residual motion during irradiation, considering 16 patients treated at CNAO with the respiratory gating protocol. The estimated tumour displacement, calculated with respect to the reference end-exhale position, was always limited (average displacement is 0.32 ± 0.65 mm over all patients) and below the maximum motion defined in the treatment plan. This supports the hypothesis of target position reproducibility, which is the crucial assumption in the gating approach. We also demonstrated the use of the model as a simulation tool to establish a patient-specific relationship between residual motion and the width of the gating window. In conclusion, the implemented method yields an estimation of the repeatability of the internal anatomy configuration during gated treatments, which can be used for further studies concerning the dosimetric impact of the estimated residual organ motion.  相似文献   

15.
目的将全新的光电耦合高电压强电流放大处理技术用于CT机的前置放大处理中,隔离噪声和高电压大电流放大图像信号,实现超低剂量扫描,高清晰成像。方法将光电耦合放大器制作成射线剂量仪,并用CT机等超低剂量120KV、3-6mA…对其曝光,并与标准射线剂量仪校准,使其输出值不仅为射线剂量值,更能显示为高电压和大电流的优质图像信噪比。结果超小电流扫描经探测和光耦放大后最大值为87.5V和0.96A,而噪声电压为0.13μV、电流仅为0.02μA,给超低剂量扫描和传输处理时的功耗及高电压的宽动态范围显示留了很大空间。结论 CT超低剂量扫描时光耦放大器可在源头彻底隔离各种噪声并超高倍放大、高电压大电流输出图像信号,可保证高清晰高分辨率成像。  相似文献   

16.
It has been repeatedly shown that functional magnetic resonance imaging (fMRI) triggers distress and neuroendocrine response systems. Prior studies have revealed that sympathetic arousal increases, particularly at the beginning of the examination. Against this background it appears likely that those stress reactions during the scanning procedure may influence task performance and neural correlates. However, the question how sympathetic arousal elicited by the scanning procedure itself may act as a potential confounder of fMRI data remains unresolved today. Thirty-seven scanner naive healthy subjects performed a simple cued target detection task. Levels of salivary alpha amylase (sAA), as a biomarker for sympathetic activity, were assessed in samples obtained at several time points during the lab visit. SAA increased two times, immediately prior to scanning and at the end of the scanning procedure. Neural activation related to motor preparation and timing as well as task performance was positively correlated with the first increase. Furthermore, the first sAA increase was associated with task induced deactivation (TID) in frontal and parietal regions. However, these effects were restricted to the first part of the experiment. Consequently, this bias of scanner related sympathetic activation should be considered in future fMRI investigations. It is of particular importance for pharmacological investigations studying adrenergic agents and the comparison of groups with different stress vulnerabilities like patients and controls or adolescents and adults.  相似文献   

17.
Rate-equilibrium free energy relationship (REFER) analysis provides information on transition-state structures and has been applied to reveal the temporal sequence in which the different regions of an ion channel protein move during a closed–open conformational transition. To date, the theory used to interpret REFER relationships has been developed only for equilibrium mechanisms. Gating of most ion channels is an equilibrium process, but recently several ion channels have been identified to have retained nonequilibrium traits in their gating cycles, inherited from transporter-like ancestors. So far it has not been examined to what extent REFER analysis is applicable to such systems. By deriving the REFER relationships for a simple nonequilibrium mechanism, this paper addresses whether an equilibrium mechanism can be distinguished from a nonequilibrium one by the characteristics of their REFER plots, and whether information on the transition-state structures can be obtained from REFER plots for gating mechanisms that are known to be nonequilibrium cycles. The results show that REFER plots do not carry information on the equilibrium nature of the underlying gating mechanism. Both equilibrium and nonequilibrium mechanisms can result in linear or nonlinear REFER plots, and complementarity of REFER slopes for opening and closing transitions is a trivial feature true for any mechanism. Additionally, REFER analysis provides limited information about the transition-state structures for gating schemes that are known to be nonequilibrium cycles.  相似文献   

18.
Metastatic mouse models of melanoma have been characterized by gross necropsy examination, histopathology, and optical imaging. To determine if the time progression, extent, and metabolism of melanoma metastases could be monitored noninvasively, serial micro-CT and small-animal PET imaging studies were performed by using a mouse model of melanoma. Juvenile female C57BL/6 mice were injected intravenously with syngenic B16-F10 melanoma cells. Serial micro-CT imaging studies were performed on anesthetized mice. Mice were necropsied at the development of adverse clinical signs or at postinjection Day 30, and tissues were collected for histopathology. In a separate study of four mice, tumor viability was assessed with 2-deoxy-2-[18F]fluoro-d-glucose ([18F]FDG) and studied by using small-animal PET imaging. A total of 59% of the mice developed metastatic tumors. Micro-CT image analysis was able to identify and follow up to 36% of metastatic lesions. Examples of metastatic lesions identified and followed up by micro-CT imaging included a lung metastasis, mandibular metastasis, subcutaneous metastasis, and tibial/femoral metastasis. Micro-CT and small-animal PET fusion imaging successfully correlated anatomic localization of glucose metabolism of the metastatic tumors. Micro-CT and small-animal PET imaging were found to be highly effective in detection and characterization of lesions produced by this metastatic melanoma model.  相似文献   

19.
We report the first in vivo cardiac magnetic resonance imaging (MRI) measurements of Theraphosidae spiders. MRI scanning is performed on six spiders under isoflurane‐induced anaesthesia. Retrospective self‐gating cine‐cardiac MRI (RG‐CINE‐MRI) is used to overcome the difficulties of prospective cardiac gating in this species. The resulting RG‐CINE‐MRI images are successfully analyzed to obtain functional cardiac parameters from live spiders at rest. Cardiac ejection fraction is found to increase with animal mass (Pearson correlation 0.849, P = 0.03) at a faster rate than myocardial tissue volume, whereas heart rate remains constant across animals. This suggests the spider heart undergoes additional biomechanical loading with age. The results of the present study demonstrate the potential for retrospective gating with respect to evaluating aspects of cardiac function in a wide range of previously inaccessible species.  相似文献   

20.
Gating current is considered to be due to the transition of dipoles, which are coupled with the membrane matrix. Based on previous theory of nerve excitation, the equation for gating current is derived; the charge displacement equation and the time constant of the gating current are also derived. Agreement with experimental data is good.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号