首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 311 毫秒
1.
With the rapid development of scaled anaerobic digestion of pig manure, the generation of liquid anaerobic digestate exceeds the farmland loading capacity, causing serious environmental pollution. Three laboratory‐scale horizontal subsurface flow constructed wetlands (CWs; planted + aeration, planted, and unplanted) were set up to investigate the feasibility of liquid digestate treatment in wetlands. Treatment capacity in different wetlands was evaluated under different influent concentrations (chemical oxygen demand [COD], 5 days biochemical oxygen demand [BOD5], and nitrogen forms). The effect of aeration and effluent recirculation on organic matter and total nitrogen removal was investigated. Results showed that integrating intermittent aeration in CWs significantly improved the oxygen condition (p < 0.01) in the wetland bed and promoted BOD5 removal to 90% in aerated CWs as compared with <15% in the unaerated CWs. Meanwhile, COD removal between these three wetlands did not show any difference and varied from 52 to 72% under influent concentration of 200–820 mg/L because of the high content of hard‐degradable organic matter in the liquid digestate. Intermittent aeration resulted in high ammonium removal (>98%) although the influent loading varied from 65 to 350 mg/L. However, intermittent aeration caused nitrate accumulation of 300 mg/L and limited total nitrogen (TN) removal of 33%. To intensify the TN removal, we verified effluent recirculation to increase the removal efficiency of TN to 78%. These results not only show the potential application of CWs for treatment of high‐strength liquid anaerobic digested slurry, but also indicate the significance of intermittent aeration on the enhanced removal of organic matter and ammonium.  相似文献   

2.
《Ecological Engineering》2006,26(3):272-282
A full-scale constructed wetlands system with a total area of 80 ha and treatment capability of 2.0 × 104 m3 d−1 was completed in October 1998 in Rongcheng, Shandong Province, China. To evaluate wastewater treatment effectiveness and seasonal performance of the system, water samples were collected and analyzed from January 1999 to December 2004. Comparison of mean inlet and outlet concentrations showed that the constructed wetland system could effectively reduce the output of SS (71.8 ± 8.4%), BOD5 (70.4 ± 9.6%), COD (62.2 ± 10.1%), total coliform (99.7%) and fecal coliform (99.6%). However, the percent reduction of ammonia nitrogen was relatively low (40.6 ± 15.3%), and total phosphorus showed the least efficient reduction (29.6 ± 12.8%). BOD5, COD, ammonia nitrogen, and total phosphorus removal efficiencies displayed seasonal variations. BOD5 and COD removal was more efficient in spring and summer than in autumn and winter whereas ammonia nitrogen and total phosphorus removal was more efficient in summer and autumn than in spring and winter. Annual variation analysis shows that COD, BOD5, and ammonia nitrogen reduction efficiencies increased from 1999 to 2004. In contrast, mean total phosphorus reduction efficiency did not change from 2001 to 2002 and began to decrease from 2003 onwards.  相似文献   

3.
An on-site pilot-scale static granular bed reactor (SGBR) system was evaluated for treating wastewater from a slaughterhouse in Iowa. The study evaluated SGBR reactor suitability for slaughterhose wastewater having high particulate COD concentration (7.9 ± 4.3 g COD/L) at 0.3–1.4 m3/m2/day of the surface loading rates. High organic removal efficiency (over 95% of TSS and VSS removal) was obtained due to the consistent treatability of SGBR system during operation at HRTs of 48, 36, 30, 24, and 20 h. The average effluent TSS, VSS, COD, soluble COD, and BOD5 concentrations were 84, 71, 301,197, and 87 mg/L, respectively. An effective backwash procedure was performed once every 7–14 days to waste a portion of the accumulated solids in the system. This procedure limited the increase in hydraulic head loss and maintained the system stability. COD removal efficiencies greater than 95% were achieved at organic loading rates ranging from 0.77 to 12.76 kg/m3/day.  相似文献   

4.
This study aimed to find optimal operation conditions for nitrogen removal from high strength slaughterhouse wastewater at 11 °C using the intermittently aerated sequencing batch reactors (IASBRs) so as to provide an engineering control strategy for the IASBR technology. Two operational parameters were examined: (1) loading rates and (2) aeration rates. Both the two parameters affected variation of DO concentrations in the IASBR operation cycles. It was found that to achieve efficient nitrogen removal via partial nitrification–denitrification (PND), “DO elbow” point must appear at the end of the last aeration period. There was a correlation between the ammonium oxidizing bacteria (AOB)/nitrite oxidizing bacteria (NOB) ratio and the average DO concentrations in the last aeration periods; when the average DO concentrations in the last aeration periods were lower than 4.86 mg/L, AOB became the dominant nitrifier population, which benefited nitrogen removal via PND. Both the nitrogen loading rate and the aeration rate influenced the population sizes of AOB and NOB. To accomplish efficient nitrogen removal via PND, the optimum aeration rate (A, L air/min) applied can be predicted according to the average organic loading rates based on mathematical equations developed in this study. The research shows that the amount of N2O generation in the aeration period was reduced with increasing the aeration rate; however, the highest N2O generation in the non-aeration period was observed at the optimum aeration rates.  相似文献   

5.
Low cost treatment of polluted wastewater has become a serious challenge in most of the urban areas of developing countries. The present study was undertaken to investigate the potential of Canna lily towards removal of carbon, nitrogen, and phosphorus from wastewater under sub-tropical conditions. A constructed wetland (CW) cell supporting vegetative layer of Canna lily was used to treat wastewater having high strength of CNP. Removal of biological oxygen demand (BOD3) and chemical oxygen demand (COD) varied between 69.8–96.4% and 63.6–99.1%, respectively. C. lily could efficiently remove carbon from a difficult to degrade wastewater at COD:BOD ratio of 24.4. Simultaneous reduction in TKN and nitrate pointed to good nitrification rates, and efficient plant assimilation as the dominant nutrient removal mechanism in the present study. Suitable Indian agro-climatic conditions favored plant growth and no evident stress over the Canna plant was observed. High removal rate of 809.8 mg/m2-day for TKN, 15.0 mg/m2-day for nitrate, and 164.2 mg/m2-day for phosphate suggests for a possible use of Canna-based CW for wastewater treatment for small, rural, and remote Indian communities.  相似文献   

6.
The performance of a pilot-scale biological nutrient removal process has been evaluated for 336 days, receiving the real municipal wastewater with a flowrate of 6.8 m3/d. The process incorporated an intermittent aeration reactor for enhancing the effluent quality, and a nitrification reactor packed with the porous polyurethane foam media for supporting the attached-growth of microorganism responsible for nitrification. The observation shows that the process enabled a relatively stable and high performance in both organics and nutrient removals. When the SRT was maintained at 12 days, COD, nitrogen, and phosphorus removals averaged as high as 89% at a loading rate of 0.42–3.95 kg COD/m3 d (corresponding to average influent concentration of 304 mg COD/L), 76% at the loading rate of 0.03–0.27 kg N/m3 d (with 37.1 mg TN/L on average), and 95% at the loading rate of 0.01–0.07 kg TP/m3 d (with 5.4 mg TP/L on average), respectively.  相似文献   

7.
Microorganism with simultaneous nitrification and denitrification ability plays a significant role in nitrogen removal process, especially in the eutrophic waters with excessive nitrogen loads. The nitrogen removal capacity of microorganism may suffer from low temperature or nitrite nitrogen source. In this study, a hypothermia aerobic nitrite-denitrifying bacterium, Pseudomonas tolaasii strain Y-11, was selected to determine the simultaneous nitrification and denitrification ability with mixed nitrogen source at 15 °C. The sole nitrogen removal efficiencies of strain Y-11 in simulated wastewater were obtained. After 24 h of incubation at 15 °C, the ammonium nitrogen fell below the detection limit from an initial value of 10.99 mg/L. Approximately 88.0 ± 0.33% of nitrate nitrogen was removed with the initial concentration of 11.78 mg/L and the nitrite nitrogen was not detected with the initial concentration of 10.75 mg/L after 48 h of incubation at 15 °C. Additionally, the simultaneous nitrification and denitrification nitrogen removal ability of P. tolaasii strain Y-11 was evaluated using low concentration of mixed NH4+-N and NO3?–N/NO2?–N (about 5 mg/L-N each) and high concentration of mixed NH4+–N and NO3?–N/NO2?–N (about 100 mg/L-N each). There was no nitrite nitrogen accumulation at the time of evaluation. The results demonstrated that P. tolaasii strain Y-11 had higher simultaneous nitrification and denitrification capacity with low concentration of mixed inorganic nitrogen sources and may be applied in low temperature wastewater treatment.  相似文献   

8.
Heterotrophic carbon utilizing microbes were acclimatized in the laboratory by inoculating sludge collected from the waste discharge pond of a small-scale rural abattoir in India in a nutrient solution intermittently fed with glucose and ammonium chloride. Cultures of 10 well-developed isolates were selected and grown in a basal medium containing glucose and ammonium chloride. Culture supernatants were periodically analyzed for ammonium nitrogen (NH4 +-N) and chemical oxygen demand (COD). Polyphasic taxonomic study of the most active nitrifier (S18) was done. Half saturation concentration (K s), maximum rate of substrate utilization (k), yield coefficient (Y) and decay coefficient (K d) were determined from the Lineweaver–Burk plot using the modified Monod equation. S18 was able to remove 97 ± 2% of (NH4 +-N) and 88 ± 3% of COD. Molecular phylogenetic study supported by physiological and biochemical characteristics assigned S18 as Achromobacter xylosoxidans. Nitrification activity of A. xylosoxidans was demonstrated for the first time, while interestingly, the distinctive anaerobic denitrification property was preserved in S18. K s values were determined as 232.13 ± 1.5 mg/l for COD reduction and 2.131 ± 1.9 mg/l for NH4 +-N utilization. Yield coefficients obtained were 0.4423 ± 0.1134 mg of MLVSS/mg of COD and 0.2461 ± 0.0793 mg of MLVSS/mg of NH4 +-N while the decay coefficients were 0.0627 ± 0.0013 per day and 0.0514 ± 0.0008 per day, respectively. After a contact period of 24 h, 650 ± 5 mg/l solids were produced when the initial concentration of COD and NH4 +-N were 1820 ± 10 mg/l and 120 ± 5.5 mg/l, respectively. This is the first report on the kinetic coefficients for carbon oxidation and nitrification by a single bacterium isolated from slaughterhouse wastewater.  相似文献   

9.
In the present study a laboratory scale anoxic/oxic reactor was used to remove the important eutrophication nutrients such as phosphorus and nitrogen from synthetic domestic wastewater. Phosphorus was removed through simultaneous precipitation and was carried out using the coagulant ferrous sulphate FeSO4 · 7H2O. Total phosphorus in the effluent was controlled to below 1 mg/l using a ferrous to phosphorus molar ratio of 2.1. pH after the addition of coagulant plays a major role in determining the molar ratio of the precipitant. Nitrogen was removed biologically in the anoxic/oxic system and the effect of simultaneous precipitation on nitrification and denitrification was investigated. The nitrification rate of the system remained unaffected during simultaneous precipitation and varied from 0.046 to 0.059 g N–NH4 +/g VSS/day. Denitrification was complete and was not affected by the coagulation process. The nitrogen removal efficiency varied from 78% to 85%. COD removal efficiency was not affected during simultaneous precipitation and was varied from 94% to 98%. The highly efficient nitrogen removal in the presence of simultaneous precipitant ferrous sulphate makes the process an ideal option for nutrient removal.  相似文献   

10.
污水地下渗滤系统脱氮效果及动力学过程   总被引:2,自引:0,他引:2  
李海波  李英华  孙铁珩  王鑫 《生态学报》2011,31(24):7351-7356
建立了模拟污水地下渗滤过程的中试系统,重点考察了水力负荷对系统脱氮效率的影响情况,建立了描述地下渗滤系统微生物脱氮过程的动力学模型.结果表明:地下渗滤系统脱氮效果好,抗水力负荷冲击能力强,处理最佳水力负荷0.125m3· m-2· d-1,出水中氮浓度低于《城市污水再生利用——景观环境用水水质》标准( GB/T 18921-2002).地下渗滤系统硝化过程符合一级动力学模型NE=Noe-0.4812t,温度是影响硝化速率的主要因素,两者的关系是KT=0.2218×1.035(T-20);出水硝态氮浓度与水力停留时间之间呈负指数关系,可描述为C=16.3475e-0.2548t,碳源是引起反硝化速率变化的主要因子.在基质层垂直深度65 cm处二次补加生活污水,反硝化速率常数由0.0355提高到0.0488.强调地下渗滤系统的污水净化功能而忽视其生态服务功能,是系统运行中普遍存在的认识误区,过高的水力负荷不利于硝化-反硝化反应的顺利进行.地下渗滤系统运行应采取适宜的水力负荷方式,促进硝化-反硝化作用.  相似文献   

11.
The aim of this study was to evaluate the impact of zeolite powders on feasibility of rapid aerobic granulation in the column-type sequencing batch reactors. After 90 days' operation, aerobic granular sludge was formed in both reactors by altering influent chemical oxygen demand/nitrogen (COD/N) ratios. R1 with zeolite powders had better removal capabilities of COD and total nitrogen than R2, which was without zeolite powders. Mixed liquor volatile suspended solid concentrations of the two reactors were 7.36 and 5.45 g/L, while sludge volume index (SVI30) values were 34.9 and 47.9 mg/L, respectively. The mean diameters of aerobic granular sludge in the above two reactors were 2.5 and 1.5 mm, respectively. Both reactors achieved the largest simultaneous nitrification and denitrification (SND) efficiency at an influent COD/N ratio of 8; however, R1 exhibited more excellent SND efficiency than R2. The obtained results could provide a novel technique for rapid aerobic granulation and N removal simultaneously, especially when treating nitrogen-rich industrial wastewater.  相似文献   

12.
Most Trichloroethylene (TCE) biodegradation reports refer to methanogenic conditions, however, in this work, enhanced sulfidogenesis and TCE biodegradation were achieved in an upflow anaerobic sludge blanket (UASB) reactor in which a completely sulfidogenic sludge, from hydrothermal vents sediments, was developed. The work was divided in three stages, (i) sludge development and sulfate reducing activity (SRA) evaluation, (ii) TCE biodegradation and (iii) SRA evaluation after TCE biodegradation. For (i) SR was 98 ± 0.1%, 84% as sulfide (H2S, 1200 ± 28 mg/L), sulfate reducing activity (SRA) was 188 ± 50 mg COD H2S/g VSS*d. For (ii) The reactor reached 74% of TCE removal, concentrations of vinyl chloride of 16 ± 0.3 μM (5% of the TCE added) and ethene 202 ± 81 μM (67% of the TCE added), SRA of 161 ± 7 mg COD H2S/g VSS*d, 68% of sulfide (H2S) production and 93% of COD removal. For (iii) SRA was of 248 ± 22 mg COD H2S/g VSS*d demonstrating no adverse effects due to TCE.Among the genera of the microorganisms identified in the sludge during TCE biodegradation were: Dehalobacter, Desulfotomaculum, Sulfospirillum, Desulfitobacterium, Desulfovibrio and Clostridium. To the best of our knowledge, this is the first report using a sulfidogenic UASB reactor to biodegrade TCE. The overall conclusions of this work are that the reactor is efficient on both, sulfate and TCE biodegradation and it could be used to decontaminate wastewater containing organic solvents and relatively high concentrations of sulfate.  相似文献   

13.
It is possible to cultivate aerobic granular sludge at a low organic loading rate and organics-to-total nitrogen (COD/N) ratio in wastewater in the reactor with typical geometry (height/diameter = 2.1, superficial air velocity = 6 mm/s). The noted nitrification efficiency was very high (99%). At the highest applied ammonia load (0.3 ± 0.002 mg NH4+–N g total suspended solids (TSS)−1 day−1, COD/N = 1), the dominating oxidized form of nitrogen was nitrite. Despite a constant aeration in the reactor, denitrification occurred in the structure of granules. Applied molecular techniques allowed the changes in the ammonia-oxidizing bacteria (AOB) community in granular sludge to be tracked. The major factor influencing AOB number and species composition was ammonia load. At the ammonia load of 0.3 ± 0.002 mg NH4+–N g TSS−1 day−1, a highly diverse AOB community covering bacteria belonging to both the Nitrosospira and Nitrosomonas genera accounted for ca. 40% of the total bacteria in the biomass.  相似文献   

14.
Industrial wastewater treatment comprises several processes to fulfill the discharge permits or to enable the reuse of wastewater. For tannery wastewater, constructed wetlands (CWs) may be an interesting treatment option. Two-stage series of horizontal subsurface flow CWs with Phragmites australis (UP series) and Typha latifolia (UT series) provided high removal of organics from tannery wastewater, up to 88% of biochemical oxygen demand (BOD5) (from an inlet of 420 to 1000 mg L−1) and 92% of chemical oxygen demand (COD) (from an inlet of 808 to 2449 mg L−1), and of other contaminants, such as nitrogen, operating at hydraulic retention times of 2, 5 and 7 days. No significant (P < 0.05) differences in performance were found between both the series. Overall mass removals of up to 1294 kg COD ha−1 d−1 and 529 kg BOD5 ha−1 d−1 were achieved for a loading ranging from 242 to 1925 kg COD ha−1 d−1 and from 126 to 900 kg BOD5 ha−1 d−1. Plants were resilient to the conditions imposed, however P. australis exceeded T. latifolia in terms of propagation.  相似文献   

15.
The operation of tidal flow was studied using a pilot‐scale system treating high strength piggery wastewater. Located on a farm in Staffordshire, UK, the system consisted of five wetland treatment stages vegetated with common reeds of Phragmites australis. Wastewater samples were collected from the inlet and outlet of each stage and analyzed for BOD5, COD, NH4‐N, NO3‐N, NO2‐N, SS, PO4‐P and pH. Average hydraulic and organic loadings on the system were 0.12 m3/m2 d and 240 g BOD/m2 d, respectively, which is considerably higher than the typical loadings on conventional subsurface flow systems. On average, BOD5 and COD were reduced by 82 % and 80 % from initial concentrations of 2000 mg/L and 2750 mg/L, respectively, across the whole system. The first‐order kinetics constant for BOD5 removal (KBOD in m/d) in this tidal flow system is approximately 2.5 times the rate constant obtainable in a typical horizontal flow system, demonstrating a more efficient removal of organic matter in tidal flow wetlands. The overall efficiency of the system was found to increase with time before stabilizing towards the end of a start‐up period. Straight‐line correlations were established between the loading and removal of BOD5 and COD. Contributions by individual stages to the overall treatment were analyzed. SEM images of wetland media demonstrated the formation of biofilms and microbial activities inside the matrices of the wetland system, which accounted for the degradations of organic pollutants.  相似文献   

16.
Fan  Ziyun  Liang  Zhiwei  Luo  Ancheng  Wang  Yunlong  Ma  Yuanyuan  Zhao  Yi  Lou  Xiansheng  Jia  Ruijie  Zhang  Yan  Ping  Shaowei 《Biodegradation》2021,32(4):403-418

The discharge of ammonia–nitrogen (NH3–N), total nitrogen (TN), chemical oxygen demand (COD), and total phosphorus (TP) in rural sewage usually exceeds the Pollutant Discharge Standard for Urban Sewage Treatment Plants (GB18918-2002). Efficient and cost-effective removal of these pollutants cannot be simultaneously realized using conventional rural sewage treatment methods. Thus, an assembled biological filter (D50?×?W50?×?H113 cm), including a phosphorus removal layer filled with solid polymeric ferric sulfate and alternating aerobic-anaerobic layers, is proposed herein. The aerobic (anerobic) layers were filled with zeolite (zeolite and composite soil) at different intervals. This system was used for the treatment of synthetic sewage having COD: 122.0–227.0 mg/L; NH3–N: 29.1–47.0 mg/L; TN: 28.0–58.0 mg/L; and TP: 2.0–3.8 mg/L. Based on optimal operation conditions (40 L/h reflow rate, without artificial aeration, and 12-h operation cycle), the system showed NH3–N, TN, COD, and TP removal efficiencies of 87.1? ± ?8.1, 83.4? ± ?7.9, 91.0? ± ?9.4, and 80.0? ± ?6.4%, respectively. Further, in the pilot-scale test, under the same optimal parameters, the removal efficiencies of NH3–N, TN, COD, and TP were 78.9? ± ?8.1, 75.4? ± ?7.9, 82? ± ?9.4, and 76? ± ?6.4%, respectively. Furthermore, in the different functional units of the system, a large number of functional bacteria capable of efficiently facilitating the simultaneous removal of the different pollutants from sewage were identified. Therefore, this proposed system, which complies with current environmental discharge regulations, can be a more sustainable approach for the treatment of unattended rural sewage.

Graphic abstract
  相似文献   

17.
The aim of the study is to assess the efficiency of a novel bioremediation system namely baffled duckweed pond (BDWP) system for the treatment of agricultural drainage water containing pharmaceuticals at different hydraulic retention times (HRTs). The removal efficiencies of acetaminophen (ACT), amoxicillin (AMX), and ampicillin (AMP) increased from 69.3 ± 8.6 to 87.3 ± 3.5%, from 52.9 ± 9.4 to 82.9 ± 5.2%, and from 55.3 ± 7.9 to 90.6 ± 2.8% at increasing the HRT from 6 to 8 days, respectively. However, ACT, AMX, and AMP removal efficiencies were slightly improved at increasing the HRT from 8 to 12 days. Diclofenac (DFC) removal efficiencies amounted to 56.6 ± 11.6, 55.7 ± 11.9, and 28.3 ± 12.9% at an HRTs of 12, 8, and 6 days, respectively. The results showed no relationship between the uptake/absorption of pharmaceuticals fractions and BOD5/chemical oxygen demand (COD) ratio except ACT where R2 was 0.84. The effect of COD/N ratio on the removal efficiency of pharmaceuticals fractions was slight. Additional removal of pharmaceuticals fractions and nitrification occurred in carrier sponge media situated in the last compartment of the BDWP.  相似文献   

18.
Phosphorus and nitrogen are the important eutrophication nutrients. They are removed in the anoxic/oxic reactor through simultaneous precipitation and biological nitrogen removal. The effect of alum a commonly used simultaneous precipitant on biological nitrification and denitrification are investigated in the present study. Simultaneous removal of phosphorus was carried out using the coagulant alum Al2(SO4)3·14H2O at 2.2 mol ratio. Before the start of simultaneous precipitation the nitrification rate of the A/O reactor was found to be 0.05 g N-NH4 +/g VSS/d. It starts to decrease with increase in coagulant dosage. The nitrification rate for alum dosage 97.13 mg/L was 0.38 g N- NH4 +/g VSS/d. There was no accumulation of nitrate in anoxic tank. The nitrogen removal efficiency of the reactor was affected and it fell from 88 to 78%. There was a slight decrease in effluent COD from 16∼20 mg/L to 8∼12 mg/L after the introduction of simultaneous precipitation into the reactor. The usage of alum as a simultaneous precipitant in the anoxic/oxic reactor was limited due to its inhibition on nitrification. Alum did not have any affect over denitrification process.  相似文献   

19.
An investigation was performed on the biological removal of ammonium nitrogen from synthetic wastewater by the simultaneous nitrification/denitrification (SND) process, using a sequencing batch biofilm reactor (SBBR). System behavior was analyzed as to the effects of sludge type used as inoculum (autotrophic/heterotrophic), wastewater feed strategy (batch/fed-batch) and aeration strategy (continuous/intermittent). The presence of an autotrophic aerobic sludge showed to be essential for nitrification startup, despite publications stating the existence of heterotrophic organisms capable of nitrifying organic and inorganic nitrogen compounds at low dissolved oxygen concentrations. As to feed strategy, batch operation (synthetic wastewater containing 100 mg COD/L and 50 mg N-NH(4)(+)/L) followed by fed-batch (synthetic wastewater with 100 mg COD/L) during a whole cycle seemed to be the most adequate, mainly during the denitrification phase. Regarding aeration strategy, an intermittent mode, with dissolved oxygen concentration of 2.0mg/L in the aeration phase, showed the best results. Under these optimal conditions, 97% of influent ammonium nitrogen (80% of total nitrogen) was removed at a rate of 86.5 mg N-NH(4)(+)/Ld. In the treated effluent only 0.2 mg N-NO(2)(-)/L,4.6 mg N-NO(3)(-)/L and 1.0 mg N-NH(4)(+)/L remained, demonstrating the potential viability of this process in post-treatment of wastewaters containing ammonium nitrogen.  相似文献   

20.
Synthetic wastewaters were prepared with different influent concentrations of ammonia nitrogen (NH3–N) and COD and the treatment studies were conducted using a rotating biological contactor (RBC). If organic removal and nitrification can be simultaneously effected in one process, it will be an ideal solution to water pollution control. The RBC used in the present study was a four stage laboratory model and the discs were modified by attaching porous netlon sheets to enhance biofilm area. The COD loads (S 0) used were about 1000 and 1500?mg/l whereas NH3–N concentrations used were in the range of 20 to 185?mg/l. Hydraulic load (q) of 0.03?m3?.?m-2?.?d-1 and ammonia nitrogen loadings in the range of 0.66 to 5.5?g NH3–N?.?m-2?.?d-1 were used. The RBC was operated at two different rotating speeds of 6 and 12?rpm. The results showed that the nitrification and percentage of COD removal were not affected up to the value of the COD/NH3–N in the range from 47 to 23 at w=6?rpm and for an average influent COD of 1003?mg/l. Beyond that range only the nitrification rate decreased much whereas the percentage of COD removal was not affected. Similarly, at an influent COD load of 1557?mg/l, the nitrification and percentage COD removal were not affected for the value of the COD/NH3–N in the range from 44 to 23 but beyond that range only the nitrification rate decreased while the percentage of COD removal was approximately constant and still high. A correlation plot between the NH3–N removed and NH3–N applied was presented at a rotating speed of 6?rpm and it was found that the nitrification rate of 3.93?g NH3–N?.?m-2?.?d-1 was achieved at ammonia loading of 5.55?g NH3–N?.?m-2?.?d-1. Also the results at w=12?rpm showed improvement of nitrification rate over those at 6?rpm.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号