1.
The study was designed to examine the effects of partial fatigue on specific mechanical parameters which characterise human tendons in vitro. Specimens prepared from 12 intact Extensor digitorum longus tendons of the foot were subjected to partial fatigue, equivalent to 25% of the median fatigue life, by a cyclic square tension-tension stress waveform at the physiological frequency of 4 Hz. The maximum stress was set at a value corresponding to 20% of the calculated ultimate tensile strength (UTS) of 100 MPa. The minimum stress was set at 1% of the UTS. Dynamic characterisation was performed at stress levels of 10% and 20% of the UTS prior to and following partial mechanical fatigue. Subsequent quasi-static tests were performed on some of the specimens. Comparative analysis of the damage ratios (DRs) of quasi-static and dynamic mechanical parameters suggested the use of the DR for dynamic tensile modulus as a good indicator of damage inflicted by mechanical fatigue. Such an approach might be used for an in vivo assessment of tendon damage.  相似文献   

2.
Damage of the annulus fibrosus is implicated in common spinal pathologies. The objective of this study was to obtain a quantitative relationship between both the number of cycles and the magnitude of tensile strain resulting in damage to the annulus fibrosus. Four rectangular tensile specimens oriented in the circumferential direction were harvested from the outer annulus of 8 bovine caudal discs (n = 32) and subjected to one of four tensile testing protocols: (i) ultimate tensile strain (UTS) test; (ii) baseline cyclic test with 4 series of 400 cycles of baseline cyclic loading (peak strain = 20% UTS); (iii & iv) acute and fatigue damage cyclic tests consisting of 4 x 400 cycles of baseline cyclic loading with intermittent loading to 1 and 100 cycles, respectively, with peak tensile strain of 40%, 60%, and 80% UTS. Normalized peak stress for all mechanically loaded specimens was reduced from 0.89 to 0.11 of the baseline control levels, and depended on the magnitude of damaging strain and number of cycles at that damaging strain. Baseline, acute, and fatigue protocols resulted in permanent deformation of 3.5%, 6.7% and 9.6% elongation, respectively. Damage to the laminate structure of the annulus in the absence of biochemical activity in this study was assessed using histology, transmission electron microscopy, and biochemical measurements and was most likely a result of separation of annulus layers (i.e., delamination). Permanent elongation and stress reduction in the annulus may manifest in the motion segment as sub-catastrophic damage including increased neutral zone, disc bulging, and loss of nucleus pulposus pressure. The preparation of rectangular tensile strip specimens required cutting of collagen fibers and may influence absolute values of results, however, it is not expected to affect the comparisons between loading groups or dose-response reported.  相似文献   

3.
Locust wings are able to sustain millions of cycles of mechanical loading during the lifetime of the insect. Previous studies have shown that cross veins play an important role in delaying crack propagation in the wings. Do cross veins thus also influence the fatigue behaviour of the wings? Since many important fatigue parameters are not experimentally accessible in a small biological sample, here we use the finite element (FE) method to address this question numerically. Our FE model combines a linear elastic material model, a direct cyclic approach and the Paris law and shows results which are in very good agreement with previously reported experimental data. The obtained results of our study show that cross veins indeed enhance the durability of the wings by temporarily stopping cracks. The cross veins further distribute the stress over a larger area and therefore minimize stress concentrations. In addition, our work indicates that locust hind wings have an endurance limit of about 40% of the ultimate tensile strength of the wing material, which is comparable to many engineering materials. The comparison of the results of the computational study with predictions of two most commonly used fatigue failure criteria further indicates that the Goodman criterion can be used to roughly predict the failure of the insect wing. The methodological framework presented in our study could provide a basis for future research on fatigue of insect cuticle and other biological composite structures.  相似文献   

4.
In a detailed study mechanical properties of tendons, muscles, nerves, blood-vessels and skin of just slaughtered pigs have been investigated in nearly stationary stress tests. Tensile tests have produced tensile strength, ultimate stress and their appropriate strains, Young's modulus and the work up to fatigue of samples. In hysteresis tests the deformation work has been determined as a function of numbers of stress cycles. The hysteresis decrease with the number of stress cycles and approaches asymptotically to cero. By preconditioning of tendons, nerves and blood-vessels to steady state significant differences of strain at tensile strength and of Young's modulus have been established. Moreover for nerves the tests have revealed significant deviations of tensile strength. Bruise tests have been carried out with muscle tissue. For the described setup the limit force can be specified, at which pathological changes appear. Subsequently conducted histological investigations have demonstrated this. In dynamical bruise tests there appeared no pathological changes in muscle tissue in spite of higher transmitted energy.  相似文献   

5.
Bone creep-fatigue damage accumulation   总被引:8,自引:0,他引:8  
Creep and fatigue tests were performed on human femoral cortical bone and the results were compared to a cumulative damage model for bone fracture. Fatigue tests in tension, compression, and reversed loading with a tensile mean stress were conducted at 2 Hz and 0.02 Hz. Load frequency had a strong influence on the number of cycles to failure but did not influence the total time to failure. Bone displayed poor creep-fracture properties in both tension and compression. The fracture surfaces of the tensile creep specimens are distinctly different than those of the compressive specimens. The results suggest that tensile cyclic loading creates primarily time-dependent damage and compressive cyclic loading creates primarily cycle-dependent damage. However, data for load histories involving both tensile and compressive loading indicate lower time to failure than predicted by a simple summation of time-dependent and cycle-dependent damage.  相似文献   

6.
Loss of fixation at the cement-bone interface can contribute to clinical loosening of cemented total hip replacements. In this study, the fatigue damage response was determined for cement-bone constructs subjected to shear fatigue loading. A typical three-phase fatigue response was observed with substantial early damage, followed by a long constant damage rate region and a final abrupt increase in damage to fracture. All of the damage resulted from creep (permanent) deformation during fatigue loading and there was no loss in cyclic stiffness. Using a Von Mises equivalent stress/strain concept, a general damage model was developed to describe the fatigue creep response of the cement-bone interface under either shear or tensile fatigue loading. Time to failure was highly correlated (r2=0.971) with equivalent creep strain rate and moderately related (r2=0.428) with equivalent initial strain for the two loading regimes. The equivalent creep strain at failure (0.052+/-0.018) was found to be independent of the applied equivalent stress. A combination of the creep damage model (to describe the damage process) with a constant final equivalent strain (as a failure criteria) could be used to assess the cement-bone failure response of cemented implant systems.  相似文献   

7.
Bacterial contamination of tendon allografts at the completion of processing has historically been about 2 %, with tendons that are found to be culture positive being discarded. Treatment of tendon allograft with hydrogen peroxide at the beginning of tissue processing may reduce bacterial contamination, however, the potential side effects of hydrogen peroxide treatment include hydrolysis of the collagen and this may alter the mechanical properties of the graft. Pairs of human tendons were used. One was washed in 3 % hydrogen peroxide for 5 min and the untreated tendon was used as a control. The ultimate tensile strength of the tendons was determined using a material testing machine. A freeze clamp technique was used to hold the tendons securely at the high loads required to cause tendon failure. There was no statistical difference in the ultimate tensile strength between the treated and untreated tendons. Mean strength ranged from Extensor Hallucis Longus at 588 Newtons to Tibialis Posterior at 2,366 Newtons. Hydrogen peroxide washing may reduce bacterial contamination of tendon allograft and does not affect the strength of the tendon.  相似文献   

8.
With the aim of studying mechanisms of the remodeling of tendons and ligaments, the effects of stress shielding on the rabbit patellar tendon were studied by performing tensile and stress relaxation tests in the transverse direction. The tangent modulus, tensile strength, and strain at failure of non-treated, control patellar tendons in the transverse direction were 1272 kPa, 370 kPa, and 40.5 percent, respectively, whereas those of the tendons stress-shielded for 1 week were 299 kPa, 108 kPa, and 40.4 percent, respectively. Stress shielding markedly decreased tangent modulus and tensile strength in the transverse direction, and the decreases were larger than those in the longitudinal direction, which were determined in our previous study. For example, tensile strength in the transverse and longitudinal direction decreased to 29 and 50 percent of each control value, respectively, after 1 week stress shielding. In addition, the stress relaxation in the transverse direction of stress-shielded patellar tendons was much larger than that of nontreated, control ones. In contrast to longitudinal tensile tests for the behavior of collagen, transverse tests reflect the contributions of ground substances such as proteoglycans and mechanical interactions between collagen fibers. Ground substances provide lubrication and spacing between fibers, and also confer viscoelastic properties. Therefore, the results obtained from the present study suggest that ground substance matrix, and interfiber and fiber-matrix interactions have important roles in the remodeling response of tendons to stress.  相似文献   

9.
Transected flexor tendons are typically treated by suture repair followed by rehabilitation that generates repetitive tendon loading. Recent results in an in vivo canine model indicate that during the first 10 days after injury and repair, there is an increase in the rigidity of the tendon repair site. Our objective was to determine whether or not ex vivo cyclic loading of repaired flexor tendons causes a similar increase in repair-site rigidity. We simulated 10 days of rehabilitation by applying 6000 loading cycles to repaired canine flexor tendons ex vivo at force levels generated during passive motion rehabilitation; we then evaluated their tensile mechanical properties. High-force (peak force, 17 N) cyclic loading increased repair-site rigidity by 100% and decreased repair-site strain by 50%, whereas low-force (5 N) loading did not change the properties of the repair site. This mechanical conditioning effect may explain, in part, the changes in tensile properties observed after only 10 days of healing in vivo. Mechanical conditioning of repaired flexor tendons by repetitive forces applied during rehabilitation may lead to increases in repair-site rigidity and decreases in strain, thereby altering the mechanical loading environment of tissues and cells at the repair site.  相似文献   

10.
Effects of cyclic stress on the mechanical properties of collagen fascicles were studied by in vitro tissue culture experiments. Collagen fascicles (approximately 300 microns in diameter) obtained from the rabbit patellar tendon were applied cyclic load at 4 Hz for one hour per day during culture period for one or two weeks, and then their mechanical properties were determined using a micro-tensile tester. There was a statistically significant correlation between tensile strength and applied peak stress in the range of 0 to 5 MPa, and the relation was expressed by a quadratic function. The maximum strength (19.4 MPa) was obtained at the applied peak stress of 1.8 MPa. The tensile strength of fascicles were within a range of control values, if they were cultured under peak stresses between 1.1 and 2.6 MPa. Similar results were also observed in the tangent modulus, which was maintained at control level under applied peak stresses between 0.9 and 2.8 MPa. The stress of 0.9 to 1.1 MPa is equivalent to approximately 40% of the in vivo peak stress which is developed in the intact rabbit patellar tendon by running, whereas that of 2.6 to 2.8 MPa corresponds to approximately 120% of the in vivo peak stress. Therefore, the fascicles cultured under applied peak stresses of lower than 40% and higher than 120% of the in vivo peak stress do not keep the original strength and modulus. These results indicate that the mechanical properties of cultured collagen fascicles strongly depend upon the magnitude of the stress applied during culture, which are similar to our previous results observed in stress-shielded and overstressed patellar tendons in vivo.  相似文献   

11.
Mechanical properties of collagen fascicles from the rabbit patellar tendon   总被引:1,自引:0,他引:1  
Tensile and viscoelastic properties of collagen fascicles of approximately 300 microns in diameter, which were obtained from rabbit patellar tendons, were studied using a newly designed micro-tensile tester. Their cross-sectional areas were determined with a video dimension analyzer combined with a CCD camera and a low magnification microscope. There were no statistically significant differences in tensile properties among the fascicles obtained from six medial-to-lateral locations of the patellar tendon. Tangent modulus, tensile strength, and strain at failure of the fascicles determined at about 1.5 percent/s strain rate were 216 +/- 68 MPa, 17.2 +/- 4.1 MPa, and 10.9 +/- 1.6 percent (mean +/- S.D.), respectively. These properties were much different from those of bulk patellar tendons; for example, the tensile strength and strain at failure of these fascicles were 42 percent and 179 percent of those of bulk tendons, respectively. Tangent modulus and tensile strength of collagen fascicles determined at 1 percent/s strain rate were 35 percent larger than those at 0.01 percent/s. The strain at failure was independent of strain rate. Relaxation tests showed that the reduction of stress was approximately 25 percent at 300 seconds. These stress relaxation behavior and strain rate effects of collagen fascicles differed greatly from those of bulk tendons. The differences in tensile and viscoelastic properties between fascicles and bulk tendons may be attributable to ground substances, mechanical interaction between fascicles, and the difference of crimp structure of collagen fibrils.  相似文献   

12.
Xenograft tendons have been used in few human studies, with variable results. With the advent of novel tissue processing techniques, which may mitigate against an immune-mediated rejection response without adversely affecting mechanical properties, there may now be a clinical role for xenograft tendons, particularly in knee ligament reconstruction. We hypothesize that ‘BioCleanse®’ processed bovine extensor digitorum medialis (EDM) tendons exhibit favorable time-zero pre-implantation biomechanical characteristics when compared to both unprocessed bovine EDM tendons and BioCleanse® processed human cadaveric allograft tibialis anterior tendons.In this in vitro case controlled laboratory study, three groups of tendons underwent a 5-stage static loading test protocol: 15 BioCleanse® bovine (BCB), 15 fresh frozen unprocessed bovine (FFB), and 12 BioCleanse® human allograft (BCA) tendons. Cross-sectional area of the grafts was measured using an alginate molding technique, and tendons were mounted within an Instron® 5565 Materials Testing System using cryogenic clamps.BCB tendons displayed a higher ultimate tensile stress (p<0.05), with equivalent ultimate failure load, creep, and modulus of elasticity when compared to the FFB tendons (p>0.05). BCB tendons had an equivalent cross-sectional area to the BCA tendons (p>0.05) whilst exhibiting a greater failure load, ultimate tensile stress, less creep and a higher modulus of elasticity (p<0.05).The BioCleanse® process did not adversely affect the time-zero biomechanical properties of bovine xenograft EDM tendons. BioCleanse® processed bovine xenograft EDM tendons exhibited superior biomechanical characteristics when compared with BioCleanse® processed allograft tibialis anterior tendons. These findings support further investigation of xenograft tendons in orthopedic soft tissue reconstructive surgery.  相似文献   

13.
The purpose of this study was to determine if an association exists between the tensile properties and the collagen fibril diameter distribution in in vitro stress-deprived rat tail tendons. Rat tail tendons were paired into two groups of 21 day stress-deprived and 0 time controls and compared using transmission electron microscopy (n = 6) to measure collagen fibril diameter distribution and density, and mechanical testing (n =6) to determine ultimate stress and tensile modulus. There was a statistically significant decrease in both ultimate tensile strength (control: 17.95+/-3.99 MPa, stress-deprived: 6.79+/-3.91 MPa) and tensile modulus (control: 312.8+/-89.5 MPa, stress-deprived: 176.0+/-52.7 MPa) in the in vitro stress-deprived tendons compared to controls. However, there was no significant difference between control and stress-deprived tendons in the number of fibrils per tendon counted, mean fibril diameter, mean fibril density, or fibril size distribution. The results of this study demonstrate that the decrease in mechanical properties observed in in vitro stress-deprived rat tail tendons is not correlated with the collagen fibril diameter distribution and, therefore, the collagen fibril diameter distribution does not, by itself, dictate the decrease in mechanical properties observed in in vitro stress-deprived rat tail tendons.  相似文献   

14.
Despite its clinical importance, the fatigue behaviour of cortical bone has not been examined as widely as its static behaviour. In the present study, specimens from the tibiae of horses have been subjected to load-controlled single step tests. The cyclic deformation behaviour was described by the development of stress-strain hysteresis parameters over the lifetime. The fatigue behaviour of bone is characterised by cyclic softening which is most distinctive towards the end of the lifetime. The microstructural damage accumulated during cyclic loading results in a loss of stiffness, asymmetrical deformation of the bone in tension and compression in cyclic creep. As shown by light and scanning electron microscopy, microcrack formation and growth is the main damage mechanism. The crack growth behaviour is strongly influenced by the microstructure, the stress components and the absolute value of the local stresses. Lower local stresses and/or compressive mean stresses lead to a dominant influence of the shear stress components with shear failure at inner interfaces. With increasing crack length, that is, higher local stress amplitudes, or tensile mean stresses, the microstructure is more and more ignored and failure occurs primarily under the influence of the normal stress components. This can be clearly seen on the fracture and specimen surfaces.  相似文献   

15.
It has recently been shown that shear wave speed in tendons is directly dependent on axial stress. Hence, wave speed could be used to infer tendon load provided that the wave speed-stress relationship can be calibrated and remains robust across loading conditions. The purpose of this study was to investigate the effects of loading rate and fluid immersion on the wave speed-stress relationship in ex vivo tendons, and to assess potential calibration techniques. Tendon wave speed and axial stress were measured in 20 porcine digital flexor tendons during cyclic (0.5, 1.0 and 2.0 Hz) or static axial loading. Squared wave speed was highly correlated to stress (r2avg = 0.98) and was insensitive to loading rate (p = 0.57). The constant of proportionality is the effective density, which reflects the density of the tendon tissue and additional effective mass added by the adjacent fluid. Effective densities of tendons vibrating in a saline bath averaged 1680 kg/m3 and added mass effects caused wave speeds to be 22% lower on average in a saline bath than in air. The root-mean-square error between predicted and measured stress was 0.67 MPa (6.7% of maximum stress) when using tendon-specific calibration parameters. These errors increased to 1.31 MPa (13.1% of maximum stress) when calibrating based on group-compiled data from ten tendons. These results support the feasibility of calculating absolute tendon stresses from wave speed squared based on linear calibration relationships.  相似文献   

16.
Achilles tendon injuries affect both athletes and the general population, and their incidence is rising. In particular, the Achilles tendon is subject to dynamic loading at or near failure loads during activity, and fatigue induced damage is likely a contributing factor to ultimate tendon failure. Unfortunately, little is known about how injured Achilles tendons respond mechanically and structurally to fatigue loading during healing. Knowledge of these properties remains critical to best evaluate tendon damage induction and the ability of the tendon to maintain mechanical properties with repeated loading. Thus, this study investigated the mechanical and structural changes in healing mouse Achilles tendons during fatigue loading. Twenty four mice received bilateral full thickness, partial width excisional injuries to their Achilles tendons (IACUC approved) and twelve tendons from six uninjured mice were used as controls. Tendons were fatigue loaded to assess mechanical and structural properties simultaneously after 0, 1, 3, and 6 weeks of healing using an integrated polarized light system. Results showed that the number of cycles to failure decreased dramatically (37-fold, p<0.005) due to injury, but increased throughout healing, ultimately recovering after 6 weeks. The tangent stiffness, hysteresis, and dynamic modulus did not improve with healing (p<0.005). Linear regression analysis was used to determine relationships between mechanical and structural properties. Of tendon structural properties, the apparent birefringence was able to best predict dynamic modulus (R2=0.88–0.92) throughout healing and fatigue life. This study reinforces the concept that fatigue loading is a sensitive metric to assess tendon healing and demonstrates potential structural metrics to predict mechanical properties.  相似文献   

17.
The effect of defect locations on the mechanical properties of armchair graphene nanoribbons (AGNRs) and the various configurations of nitrogen (N) doping on the mechanical properties of AGNRs were examined using molecular dynamics (MD) simulations. The variation of the Young’s modulus (YM) and the ultimate tensile strength (UTS) of pyridinic-N, graphitic-N, and pyrrolic-N by increasing the concentration of N doping was investigated. The results of MD simulations show that the defect location has a significant effect on the UTS and failure strain (FS) of AGNRs in both vertical and horizontal directions. In the horizontal direction, variations of the UTS and FS are lower than in the vertical direction. On the other hand, the variations of the YM is almost similar in vertical and horizontal directions. The results of this work indicate that the UTS and FS of AGNRs are more sensitive than the YM of AGNRs for different defect directions. Pyridinic-N improves the mechanical properties of the defective AGNR and performs better YM and UTS values than the graphitic-N. Substitution N atoms, which are located at the defective sites and/or at the edges of AGNRs, are mechanically more favorable. Pyrrolic-N configuration has the lowest mechanical properties among the other configurations. Furthermore, pyrrolic-N with Stone-Wales-1 (SW-1) type of defect has higher mechanical properties than pyrrolic-N with Stone-Wales-2 (SW-2) type of defect.  相似文献   

18.
Tensile fatigue tests of acrylic bone cement were conducted under strain control in a wet environment at 37 degrees C. A constant strain rate of 0.02s-1 was used, resulting in physiologic loading frequencies. Comparison of the tensile fatigue data with the results of previous tension-compression fatigue tests indicates that fatigue failure is governed primarily by the maximum cyclic tensile strain. The compressive portion of the loading cycle has little effect on the number of cycles to failure. A new empirically derived equation is introduced to describe the influence of mean strain and strain amplitude on fatigue endurance. The results emphasize the critical role tensile strains may play in cement failure and loosening of total joint replacements.  相似文献   

19.
Whole body vibration (WBV) has been extensively studied as an anabolic stimulus for bone and muscle. Therapeutic WBV delivers low magnitude, high frequency vibrations to tissues, eliciting biological and structural responses. This study investigated the effect of 0.3G (Peak-to-Peak), 30Hz sinusoidal vibration on intact flexor carpi ulnaris tendons in rats. Experimental rats were subjected to twenty minutes of WBV daily for five days a week for a total of five weeks. The tendon cross-sectional area and the structural properties of the muscle-tendon-bone unit under tensile loading to failure were evaluated. Initial body weights were similar between the groups and the mean change in body weight of the animals of each group did not differ. The cross-sectional area of the tendons of the vibrated animals was found to be 32% greater (P<0.05) than the controls and the structural stiffness of the vibrated tendons was found to be 41% greater (P<0.05) than the controls. For specimens that failed in the midsubstance of the tendon, a trend (P=0.087) for increased ultimate load was observed in the vibrated tendons compared to the controls. No differences in material properties were observed except for the strain to ultimate load, which was reduced 22% in the vibrated group. These initial findings suggest that vibration may serve as an anabolic stimulus to tendon similar to its effects on bone and muscle. These findings are important as they open the potential that low magnitude, high frequency vibration might serve as a means to accelerate tendon healing.  相似文献   

20.
Verteramo A  Seedhom BB 《Biorheology》2004,41(3-4):203-213
THE AIMS of this study were: (i) to investigate the variation in the tensile properties of articular cartilage with depth through cartilage thickness and fibre orientation; (ii) to determine the effect of strain rate on tensile properties of articular cartilage. MATERIALS AND METHOD: All experimental work was performed on cartilage specimens taken from two bovine knee joints. Osteochondral plugs 12 mm in diameter were harvested with a special reamer from the femur and the tibial plateaux of each knee. Slices (0.2 mm thick), of articular cartilage were cut from the plug with a microtome. The predominant orientation of the collagen fibres on the cartilage surface was determined using the pinpricking technique. Each specimen used for the tensile test was cut, so as to produce a dumbbell shape, with a gauge length of 6 mm. Uniaxial tensile tests were performed on each specimen in order to determine the tensile Young's modulus, and ultimate tensile strength (UTS). In this investigation, these tensile tests were carried out at different strain rate: 1, 20, 50 and 70%/sec. RESULTS: As regards the zonal properties, it was found that tensile stiffness was greater in the superficial layer than in deep layer. However, a few specimens from the deep layer displayed similar or greater stiffness compared to the superficial layer. With respect to the directional properties, the specimens oriented parallel to the predominant alignment of collagen, were stiffer than those, which were perpendicular to it in each layer. However, only the results regarding the deep layer can be considered statistically significant. In regard to the variation of modulus with the strain-rate, the results showed that there is no significant increase of the modulus with increasing strain rate from 20 to 50% per second. However, at 70% per second, articular cartilage stiffness considerably increased by up to one order of magnitude greater than that determined at lower strain rates in both the superficial and deep layer. Moreover, the UTS of cartilage specimens tested at 70% per second showed a significant rise, reaching values of four to five times that of those measured at 1, 20 or 50% per second. CONCLUSION: The steep increases in both the stiffness and ultimate tensile strength of cartilage at high strain rates point to the existence in cartilage of a mechanism for its protection from damage by stresses arising in trauma, which are usually applied at high rates. This mechanism needs to be elucidated. The reduced anisotropy found in the present study pointed out that collagen is likely to be less organized in bovine cartilage than in the human and therefore, a study of its ultra-structure would be appropriate.  相似文献   