首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 633 毫秒
1.
This study examines a novel sample preparation method for the determination of 11 hydroxy metabolites of polychlorinated biphenyls (PCBs) in plasma and organ tissues, followed by gas chromatography with mass spectrometric detection (GC/MS). The clean-up method was optimized to eliminate the interference matter by using a silica column and 10 mL of n-hexane/dichloromethane (4:6, v/v) as an eluent. Solid-phase and solvent extraction procedures were used for the plasma and tissues samples, respectively. Compared to C(18) and C(8) solid-phase, C(2) showed higher extraction efficiency with n-hexane as the eluent for plasma. The hydroxy-PCB extraction recoveries achieved with this combined extraction and clean-up procedure from plasma ranged from 87 to 117%, while those from tissues ranged from 82 to 111%. The linear detector responses for propyl derivatives of hydroxy-PCBs were obtained with the coefficients of determination varying from 0.992 to 0.998 in the concentration range of 0.1-20 ng mL(-1). The method detection limits ranged from 0.1 to 0.5 ng mL(-1) in 1 mL of plasma and from 0.1 to 0.5 ng g(-1) in 1g of tissues. This procedure was successfully applied to the study of 3-OH-2,3',4,4',5-PeCB in rat plasma and liver samples after intraperitoneal injection (20 mg/kg) of 2,3',4,4',5-PeCB.  相似文献   

2.
A rapid and sensitive method to determine colchicine in human plasma by liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been developed. Colchicine and the internal standard (I.S.), tegafur, were extracted from the matrix with n-hexane:dichloromethane:isopropanol (300:150:15, v/v/v) and separated by reversed-phase high-performance liquid chromatography (HPLC) using formic acid:10 mM ammonium acetate:methanol (1:49:75, v/v/v) as the mobile phase in a run time of 2.5 min. Detection was carried out by electrospray positive ionization mass spectrometry in the multiple-reaction monitoring (MRM) mode. The assay was linear in the concentration range 0.050-10 ng/ml with intra- and inter-day precision (as relative standard deviation (R.S.D.)) of <2 and <7%, respectively. The method was applied to a pharmacokinetic study of colchicine in healthy volunteers given an oral dose of 2.0 mg.  相似文献   

3.
A selective and sensitive high performance liquid chromatography-electrospray ionization mass spectrometry method has been developed for the determination of tolterodine tartrate in human plasma. With oxybutynin as internal standard, tolterodine tartrate was extracted from plasma with n-hexane: isopropanol (95:5, v/v). The organic layer was evaporated and the residue was redissolved in mobile phase comprised of acetonitrile-water (10 mM CH3COONH4, pH 3.0)=50:50 (v/v). An aliquot of 10 microl was chromatographically analyzed on a prepacked Shimadzu Shim-pack VP-ODS C18 column (150 mmx2.0 mm I.D.) by means of selected-ion monitoring (SIM) mode mass spectrometry. Standard curves were linear (r=0.9993) over the concentration range of 0.1-30.0 ng/ml and had good accuracy and precision. The within- and between-batch precisions were within 10% relative standard deviation. The limit of detection (LOD) was 0.05 ng/ml. The validated LC-ESI-MS method has been used successfully to study tolterodine tartrate pharmacokinetic, bioavailability and bioequivalence in 20 healthy male volunteers.  相似文献   

4.
A sensitive and selective liquid chromatography-tandem mass spectrometry method (LC-MS-MS) for the simultaneous estimation of bulaquine and primaquine has been developed and validated in monkey plasma. The mobile phase consisted of acetonitrile/ammonium acetate buffer (20 mM, pH 6) (50:50 v/v) at a flow-rate of 1 ml/min. The chromatographic separations were achieved on two spheri cyano columns (5 microm, 30 x 4.6 mm I.D.) connected in series. The quantitation was carried out using a Micromass LC-MS-MS with an electrospray source in the multiple reaction monitoring (MRM) mode. The analytes were quantified from the summed total ion value of their two most intense molecular transitions. This is another novel method leading to increased sensitivity and precision. A simple liquid-liquid extraction with 2 x 1.0 ml n-hexane/ethyl acetate/dimethyloctyl amine (90:10:0.05, v/v) was utilized. The method was validated in terms of recovery, linearity, accuracy and precision (within- and between-assay variation). The recoveries from spiked control samples were >or=90 and 50% for bulaquine and primaquine, respectively. Linearity in plasma was observed over a dynamic range of 1.56-400 and 3.91-1000 ng/ml for bulaquine and primaquine, respectively.  相似文献   

5.
A simple, selective and sensitive high-performance liquid chromatographic method with spectrophotometric detection was developed for the determination of antihyperglycemic agent metformin in human plasma using a novel sample extraction procedure. Liquid-liquid extraction of metformin and ranitidine (as internal standard) from plasma samples was performed with 1-butanol/n-hexane (50:50, v/v) in alkaline condition followed by back-extraction into diluted acetic acid. Chromatography was carried out using a silica column (250 mmx4.6 mm, 5 microm) under isocratic elution with acetonitrile-40 mM aqueous sodium dihydrogen phosphate (25:75, v/v), pH 6. The limit of quantification (LOQ) was 15.6 ng/ml and the calibration curves were linear up to 2000 ng/ml. The mean absolute recoveries for metformin and internal standard using the present extraction procedure were 98 and 95%, respectively. The intra- and inter-day coefficient of variation and percent error values of the assay method were all less than 8.3%.  相似文献   

6.
A quantitative and selective method has been developed for the determination of a novel local anaesthetic compound pentacaine, trans-2-(1-pyrrolidinyl)cyclohexyl-3-pentyloxycarbanilate hydrochloride, in biological samples. After ion pair extraction from 1 M HCl into 1,2-dichloroethane, pentacaine and a structurally related internal standard were derivatized to prevent thermal decomposition in the gas chromatograph. An on-column methylation technique with trimethylanilinium hydroxide was used. Determination was performed by gas chromatography/mass spectrometry (GC/MS) with selected ion monitoring. Interferences by endogenous lipophilic constituents were avoided by including an n-hexane wash before the ion pair extraction. This wash step did not reduce the drug recoveries. The method gave linear results over a concentration range of 5-100 ng ml-1 with a coefficient of variation less than 10% at 5 ng pentacaine ml-1. Specimens of plasma, whole blood, urine as well as in vitro preparations such as hepatic microsomes were successfully analysed.  相似文献   

7.
A simple and rapid high-performance liquid chromatographic method with fluorescence detection was developed for the determination of loratadine in small volume plasma samples. Liquid-liquid extraction of loratadine and diazepam (as internal standard) from plasma samples was performed with n-butyl alcohol/n-hexane (2:98, v/v) in alkaline condition followed by back-extraction into diluted perchloric acid. Chromatography was carried out using a C8 column (250 x 4.6 mm, 5 microm) under isocratic elution with acetonitrile-20 mM sodium dihydrogen phosphate-triethylamine (43:57:0.02, v/v), pH 2.4. Analyses were run at a flow-rate of 1.0 ml/min at room temperature. The method was specific and sensitive with a quantitation limit of 0.62 ng/ml and a detection limit of 0.2 ng/ml at a signal-to-noise ratio of 3:1. The mean absolute recovery of loratadine from plasma was 84%, while the intra-and inter-day coefficient of variation and percent error values of the assay method were all less than 9.7%. Linearity was assessed in the range of 0.62-20 ng/ml in plasma with a correlation coefficient of greater than 0.999. The method has been used to analyze several hundred human plasma samples for bioavailability studies.  相似文献   

8.
A rapid, selective and sensitive high-performance liquid chromatographic method with spectrophotometric detection was developed for the determination of clarithromycin in human plasma. Liquid-liquid extraction of clarithromycin and norverapamil (as internal standard) from plasma samples was performed with n-hexane/1-butanol (98:2, v/v) in alkaline condition followed by back-extraction into diluted acetic acid. Chromatography was carried out using a CN column (250 mm x 4.6 mm, 5 microm) under isocratic elution with acetonitrile-50 mM aqueous sodium dihydrogen phosphate (32:68, v/v), pH 4.5. Detection was made at 205 nm and analyses were run at a flow-rate of 1.0 ml/min at 40 degrees C. The analysis time was less than 11 min. The method was specific and sensitive with a quantification limit of 31.25 ng/ml and a detection limit of 10 ng/ml in plasma. The mean absolute recovery of clarithromycin from plasma was 95.9%, while the intra- and inter-day coefficient of variation and percent error values of the assay method were all less than 9.5%. Linearity was assessed in the range of 31.25-2000 ng/ml in plasma with a correlation coefficient of greater than 0.999. The method was used to analyze several hundred human plasma samples for bioavailability studies.  相似文献   

9.
A method is described which enables determination of vitamin D3 and its physiologically most important metabolites, i.e. 25-OHD3, 24,25-(OH)2D3, 25,26-(OH)2D3 and 1,25-(OH)2D3 in a plasma sample of about 2 to 4 ml. The whole procedure involves two preparative and one analytical steps: Extraction with methanol/methylene chloride (2:1), chromatographic separation on Lipidex 5000 using a stepwise gradient of n-hexane and chloroform and finally HPLC separation on Zorbax-Sil columns with n-hexane isopropanol mixtures and subsequently reversed phase separation on RP 18-columns and mixtures of methanol and water. Except for 1,25-(OH)2D3 all D compounds were quantified by UV-detection with 1.4 ng of substance being the lowest detectable amount. 1,25-(OH)2D3 was measured by radioimmunoassay. Prior to HPLC analysis the extract was separated into three fractions on Lipidex 5000 which contained 1) vitamin D3, 2) 25-OHD3 and 3) the dihydroxy metabolites. The three fractions were separated by HPLC using different mixtures of isopropanol/n-hexane and methanol/water, respectively. Retention times of the individual D-components longer than 10 min appeared to be essential to separate these compounds from accompanying material. Overall recoveries of the individual metabolites were for vitamin D3 48.9%, for 25-OHD3 54.2%, for 24,25-(OH)2D3 50.9% and for 1,25-(OH)2D3 52.5%. Application of the methods to plasma samples from pigs with pseudovitamin D deficiency rickets, typ I, revealed a reduced concentration of 1,25-(OH)2D3 and 24,25-(OH)2D3 and an elevated level of 25-OHD3 in these animals. The results obtained by this method contributed substantially to a better understanding of the aetiological factors associated with this disease.  相似文献   

10.
A highly sensitive and enantioselective method has been developed and validated for the determination of levocetirizine [(R)-cetirizine] in human plasma by normal-phase liquid chromatography coupled to tandem mass spectrometry with an atmospheric pressure chemical ionization (APCI) interface in the positive ion mode. Enantioselective separation was achieved on a CHIRALPAK AD-H column using an isocratic mobile phase consisting of a mixture of n-hexane, ethyl alcohol, diethylamine, and acetic acid (60:40:0.1:0.1, v/v/v/v). Levocetirizine-D(8) was used as an internal standard (IS). Levocetirizine and the IS were detected by multiple-reaction monitoring (MRM). Mass transitions of analyte and IS were m/z 389.2→201.1 and 397.2→201.1, respectively. Under optimized analytical conditions, a baseline separation of two enantiomers and IS was obtained in less than 11 min. Samples were prepared by a simple two-step extraction by protein precipitation using acetonitrile followed by liquid-liquid extraction with a n-hexane-dichloromethane mixture (50:50, v/v). The standard curve for levocetirizine was linear (r(2)>0.995) in the concentration range 0.5-300 ng/mL. Recovery was between 97.0 and 102.2% at low, medium, and high concentration. The limit of quantification (LOQ) was 0.5 ng/mL. Other method validation parameters, such as precision, accuracy, and stability, were very satisfactory. Finally, the proposed method was successfully applied to the study of enantioselective oral pharmacokinetics of levocetirizine in healthy Korean volunteers.  相似文献   

11.
This investigation describes a new precise, sensitive and accurate stereoselective HPLC method for the simultaneous determination of donepezil enantiomers in tablets and plasma with enough sensitivity to follow its pharmacokinetics in rats up to 12h after single oral dosing. Enantiomeric resolution was achieved on a cellulose tris (3,5-dimethylphenyl carbamate) column known as Chiralcel OD, with UV detection at 268 nm, and the mobile phase consisted of n-hexane, isopropanol and triethylamine (87:12.9:0.1). Using the chromatographic conditions described, donepezil enantiomers were well resolved with mean retention times of 12.8 and 16.3 min, respectively. Linear response (r > 0.994) was observed over the range of 0.05-2 microg/ml of donepezil enantiomers, with detection limit of 20 ng/ml. The mean relative standard deviation (R.S.D.%) of the results of within-day precision and accuracy of the drug were < or =10%. There was no significant difference (p > 0.05) between inter- and intra-day studies for each enantiomers which confirmed the reproducibility of the assay method. The mean extraction efficiency was 92.6-93.2% of the enantiomers. The proposed method was found to be suitable and accurate for the quantitative determination of donepezil enantiomers in tablets. The assay method also shows good specificity to donepezil enantiomers, and it could be successfully applied to its pharmacokinetic studies and to therapeutic drug monitoring.  相似文献   

12.
A high-performance liquid chromatographic assay has been developed and validated for the determination of the anticancer agent CI-980 in plasma samples from pediatric patients. After ether extraction from alkaline plasma, the CI-980 was chromatographed on a (R)-N-(3,5-dinitrobenzoyl)phenylglycine stationary phase using a mobile phase composed of hexane–isopropanol (70:30, v/v) modified with 1% acetonitrile. The method was linear over a 0.25 to 25.00 ng/ml range and the intra- and inter-day coefficients of variation (C.V.s) were less than 15%. The method was applied to the determination of the plasma concentration–time profile for a pediatric patient receiving 3.5 mg/m2 of CI-980 per day as a continuous 72-h infusion.  相似文献   

13.
Sensitive and selective determination of valproic acid in plasma by high-performance liquid chromatography (HPLC) is usually achieved with pre-column derivatization. In the present work, the derivatization is omitted due to using a simple but highly selective plasma extraction procedure and an optimized chromatographic condition. Valproic acid and the internal standard octanoic acid were extracted from plasma samples with n-hexane under acidic condition followed by back-extraction into diluted triethylamine. Chromatography was performed on a CN column (250 x 4.6 mm, 5 microm) under isocratic elution with acetonitrile-40 mM aqueous sodium dihydrogen phosphate (30:70, v/v), pH 3.5. Detection was made at 210 nm and analyses were run at a flow-rate of 1 ml/min. The method was specific and sensitive with a quantification limit of 1.25 microg/ml and a detection limit of 0.1 microg/ml in plasma. The mean absolute recovery for valproic acid using the present plasma extraction procedure was 75.8%. The intra- and inter-day coefficient of variation and percent error values of the assay method were all in acceptable range. Calibration curves were linear (r>0.999) from 1.25 to 320 microg/ml in plasma.  相似文献   

14.
In the present studies, to give momentum to traditionally low throughput pharmacokinetic screening, a bioanalytical method based on the concept of sample pooling for simultaneous bioanalysis of multiple compounds is discussed. A sensitive, selective, specific and rapid HPLC/ESI-MS/MS assay method was developed and validated for the simultaneous quantitation of three novel trioxane antimalarials (99-357, 99-408 and 99-411) in rat plasma using trioxane analogue as internal standard. The suitably validated bioanalytical method was then further extrapolated to rabbit and monkey plasma by performing partial validation. Extraction from the plasma involves a simple two-step liquid-liquid extraction with n-hexane. The analytes were chromatographed on a cyano column by isocratic elution with acetonitrile:ammonium acetate buffer (pH 6) (85:15, v/v) and analyzed by mass spectrometry in multiple reaction-monitoring (MRM) mode. The chromatographic run time was 5.5 min and the weighted (1/x(2)) calibration curves were linear over a range of 1.56-200 ng/ml. The limit of detection (LOD) and lower limit of quantification (LLOQ) in rat plasma, rabbit plasma and monkey plasma were 0.78 and 1.56 ng/ml, respectively, for all three analytes. The intra- and inter-batch accuracy and precision in terms of % bias and % relative standard deviation were found to be well within the acceptable limits (< 15%). The average absolute recoveries of 99-357, 99-408 and 99-411 from spiked plasma samples were > 90%, > 70% and > 60%, respectively. The assay method described here could be applied to study the pharmacokinetics of 99-357, 99-408 and 99-411 using sample-pooling technique.  相似文献   

15.
A simple, rapid, sensitive and specific liquid chromatography-tandem mass spectrometry method was developed and validated for quantification of metoprolol tartrate (MT) and ramipril, in human plasma. Both the drugs were extracted by liquid-liquid extraction with diethyl ether-dichloromethane (70:30, v/v). The chromatographic separation was performed on a reversed-phase C8 column with a mobile phase of 10 mM ammonium formate-methanol (3:97, v/v). The protonated analyte was quantitated in positive ionization by multiple reaction monitoring with a mass spectrometer. The method was validated over the concentration range of 5-500 ng/ml for metoprolol and ramipril in human plasma. The precursor to product ion transitions of m/z 268.0-103.10 and m/z 417.20-117.20 were used to measure metoprolol and ramipril, respectively.  相似文献   

16.
We present a method for the enantioselective analysis of albendazole sulfoxide (ABZSO) in plasma for application in clinical pharmacokinetic studies. ABZSO enantiomers were separated on a 5-μm Chiralcel OB-H® column (4.6 × 150 mm) using hexane:ethanol (93:7, v/v) as the mobile phase and fluorescence detection. ABZSO was extracted with chloroform:isopropanol (8:2, v/v) from 500-μl aliquots of acidified plasma, with full drug recovery. The proposed method presented quantitation limits of 20 ng/ml for (−)ABZSO and 50 ng/ml for (+)ABZSO and was linear up to a concentration of 5,000 ng/ml of each enantiomer. Chirality 9:722–726, 1997. © 1997 Wiley-Liss, Inc.  相似文献   

17.
目的:建立同时检测粪便中度洛西汀、氟西汀、艾斯西酞普兰三种抗抑郁药物的高效液相色谱串联质谱(HPLC-MS)方法。方法:样品经正己烷-异丙醇(95:5,v/v)预处理后,以超纯水和乙腈混合液作为流动相进行梯度洗脱,在Agilent ZORBAX SB-C18液相色谱柱(2.1 mm×100 mm,3.5 μm)上分离后用电喷雾串联质谱法检测,内标法定量。结果:粪便样品中度洛西汀、氟西汀、艾斯西酞普兰的加标回收率为61.6%~116.5%,精密度为 2.80%~12.9%(n=5),线性方程相关系数(r)均大于0.995,检出限分别为0.1 μg/g、1 μg/g、0.001 μg/g,定量限分别为0.5 μg/g、2 μg/g、0.005 μg/g,符合高效液相色谱串联质谱的分析要求。结论:该方法能够简单、准确检测出粪便中度洛西汀、氟西汀、艾斯西酞普兰这三种抗抑郁药的含量。  相似文献   

18.
Here we present a sensitive and specific liquid chromatography-tandem mass spectrometric method for the quantification of dimenhydrinate (I) in human plasma. Sample preparation is conducted using citalopram (II) addition as an internal standard (IS), liquid-liquid extraction with basified plasma using a mixture hexane/acetate (1:1, v/v) as the extracting solvent, and the final extract reconstituted in the mobile phase. I and II (IS) were injected in a C8 column with the mobile phase composed of methanol:isopropanol:water:formic acid (78.00:19.92:2.00:0.08, v/v/v/v) and monitored using a positive electrospray source with tandem mass spectrometry analyses. The selected reaction monitoring (SRM) was set using precursor ion and product ion combinations of m/z 256.0>167.0 and m/z 325.0>109.0 for I and II, respectively. The limit of quantification (LOQ) was 0.4 ng/mL, the dynamic range being 0.4-200 ng/mL. Validation results on linearity, specificity, accuracy, precision and stability, as well as on application to the analysis of plasma samples taken up to 24 h after oral administration of 100 mg of dimenhydrinate in healthy volunteers demonstrated its applicability to bioavailability studies.  相似文献   

19.
Methocarbamol enantiomers in rat and human plasma were quantified using a stereospecific high-performance liquid chromatographic method. Racemic methocarbamol and internal standard, (R)-(−)-flecainide, were isolated from plasma by a single-step extraction with ethyl acetate. After derivatization with the enantiomerically pure reagent (S)-(+)-1-(1-naphthyl)ethyl isocyanate, methocarbamol diastereomers and the (R)-flecainide derivative were separated on a normal-phase silica column with a mobile phase consisting of hexane—isopropanol (95:5, v/v) at a flow-rate of 1.6 ml/min. Ultraviolet detection was carried out at a wavelength of 280 nm. The resolution factor between the diastereomers was 2.1 (α = 1.24). An excellent linearity was observed between the methocarbamol diastereomers/internal standard derivative peak-area ratios and plasma concentrations, and the intra- and inter-day coefficients of variation were always <9.8%. The lowest quantifiable concentration was 0.5 μg/ml for each enantiomer (coefficients of variation of 9.8 and 8.8% for (S)- and (R)-methocarbamol, respectively), while the limit of detection (signal-to-noise ratio 3:1) was approximately 10 ng/ml. The assay was used to study the pharmacokinetics of methocarbamol enantiomers in a rat following intravenous administration of a 120 mg/kg dose of racemic methocarbamol and to evaluate plasma and urine concentrations in a human volunteer after oral administration of a 1000-mg dose of the racemate. The method is suitable for stereoselective pharmacokinetic studies in humans as well as in animal models.  相似文献   

20.
A simple, sensitive and selective HPLC method with UV detection (315 nm) was developed and validated for quantitation of entacapone in human plasma, the newest addition to the group of antiparkinsonian agents. Following a single-step liquid-liquid extraction (LLE) with ethyl acetate/n-hexane (30/70, v/v), the analyte and internal standard (rofecoxib) were separated using an isocratic mobile phase of 30 mM phosphate buffer (pH 2.75)/acetonitrile (62/38, v/v) on a reverse phase C18 column. The lower limit of quantitation was 25 ng/mL, with a relative standard deviation of less than 8%. A linear range of 25-2500 ng/mL was established. This HPLC method was validated with between-batch and within-batch precision of 2.2-4.2% and 1.7-7.8%, respectively. The between-batch and within-batch accuracy was 98.7-107.5% and 97.5-106.0%, respectively. Frequently coadministered drugs did not interfere with the described methodology. Stability of entacapone in plasma was excellent, with no evidence of degradation during sample processing (autosampler) and 30 days storage in a freezer. This validated method is sensitive, simple and repeatable enough to be used in pharmacokinetic studies.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号