首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Flush-mounted hot film anemometer accuracy in pulsatile flow   总被引:2,自引:0,他引:2  
The accuracy of a flush-mounted hot film anemometer probe for wall shear stress measurements in physiological pulsatile flows was evaluated in fully developed pulsatile flow in a rigid straight tube. Measured wall shear stress waveform based on steady flow anemometer probe calibrations were compared to theoretical wall shear stress waveforms based on well-established theory and measured flow rate waveforms. The measured and theoretical waveforms were in close agreement during systole (average deviation of 14 percent at peak systole). As expected, agreement was poor during diastole because of flow reversal and diminished frequency response at low shear rate.  相似文献   

2.
An experimental and numerical study of pulsatile laminar flow in a plane 90-degree bifurcation is presented. Detailed LDA velocity measurements of the oscillatory flow field have been carried out. The numerical predictions, which are based on an iterative, finite-difference numerical procedure using primitive dependent variables, are in good agreement with the measurements. The results show that one separation zone is established near the bottom wall of the main duct and another near the upstream wall of the branch. The location and size of the separation zones vary within the cycle and are influenced by the Reynolds number, the flow rate ratio, and the Stokes number.  相似文献   

3.
Pressure drop and flow rate measurements in a rigid cast of a human aortic bifurcation under both steady and physiological pulsatile flow conditions are reported. Integral momentum and mechanical energy balances are used to calculate impedance, spatially averaged wall shear stress and viscous dissipation rate from the data. In the daughter branches, steady flow impedance is within 30% of the Poiseuille flow prediction, while pulsatile flow impedance is within a factor of 2 of fully developed, oscillatory, straight tube flow theory (Womersley theory). Estimates of wall shear stress are in accord with measurements obtained from velocity profiles. Mean pressure drop and viscous dissipation rate are elevated in pulsatile flow relative to steady flow at the mean flow rate, and the exponents of their Reynolds number dependence are in accord with available theory.  相似文献   

4.
Pulsatile flow was studied in physiologically realistic models of a normal and a moderately stenosed (30% diameter reduction) human carotid bifurcation. Time-resolved velocity measurements were made using magnetic resonance imaging, from which wall shear stress (WSS) vectors were calculated. Velocity measurements in the inflow and outflow regions were also used as boundary conditions for a computational fluid dynamics (CFD) model. Experimental flow patterns and derived WSS vectors were compared qualitatively with the corresponding CFD predictions. In the stenosed phantom, flow in the bulb region of the "internal carotid artery" was concentrated along the outer wall, with a region of low and recirculating flow near the inner wall. In the normal phantom, the converse was found, with a low flow region near the outer wall of the bulb. Time-averaged WSS and oscillatory shear index were also markedly different for the two phantoms.  相似文献   

5.
Experimental results are presented on physiological pulsatile flow past caged ball and tilting disc aortic valve prostheses mounted in an axisymmetric chamber incorporated in a mock circulatory system. The measurements of velocity profiles and turbulent normal stresses during several times in a cardiac cycle were obtained using laser-Doppler anemometry. Our results show that with increased angle of opening for the tilting disc valves, a large but locally confined vortex is observed along the wall in the minor flow region throughout most of the cardiac cycle. The turbulent normal stresses measured downstream to the tilting disc in the minor flow region parallel to the tilt axis were found to be larger than those measured downstream to the caged ball valves. Comparison of measurements with steady flow at flow rates comparable to peak pulsatile flow rate show that the turbulent normal stresses are larger by a factor of two in pulsatile flow with a frequency of 1.2 Hz.  相似文献   

6.
7.
Visualization experiments were performed to elucidate the complicated flow pattern in pulsatile flow through arterial bifurcations. Human common carotid arteries, which were made transparent, and glass-models simulating Y- and T-shaped bifurcations were used. Pulsatile flow with wave forms similar to those of arterial flow was generated with a piston pump, elastic tube, airchamber, and valves controlling the outflow resistance. Helically recirculating flow with a pattern similar to that of the horseshoe vortex produced around wall-based protuberances in circular tubes was observed in pulsatile flow through all the bifurcations used in the present study. This flow type, which we shall refer to as the horseshoe vortex, has also been demonstrated to occur at the human common carotid bifurcation in steady flow with Reynolds numbers above 100. Time-varying flows also produced the horseshoe vortex mostly during the decelerating phase. Fluid particles of dye solution approaching the bifurcation apex diverged, divided into two directions perpendicularly, and then showed helical motion representing the horseshoe vortex formation. While this helical flow was produced, the stagnation points appeared on the wall upstream of the apex. Their position was dependent upon the flow distribution ratio between the branches in the individual arteries. The region affected by the horseshoe vortex was smaller during pulsatile flow than during steady flow. Lowering the Reynolds number together with the Womersley number weakened the intensity of helical flow. A separation bubble, resulting from the divergence or wall roughness, was observed at the outer or inner wall of the branch vessels and made the flow more complicated.  相似文献   

8.
《Biorheology》1995,32(1):43-59
The structure of pulsatile flow in a rigid aortic bifurcation model was studied by means of a flow visualization technique and three-dimensional laser-Doppler anemometry. The model was made of glass, having the same shape as that of the average human aortic bifurcation. It was installed into a mock circulatory loop that generated physiological pulsatile flow. Flow separation was observed during accelerated and decelerated flow periods. Double helical flow existed inside the flow separation in the early accelerated flow period. In the decelerated flow period, disturbed flow appeared behind the separation zone. Flow was strongly disturbed during the back flow period, and then was gradually stabilized in the forward flow period. The flow separation and the disturbances released from the flow separation zone greatly influenced near-wall velocities along the lateral wall. The wave form of the near-wall velocity in the flow separation zone was much different from that observed in the aortic portion and behind the separation zone; for example, the magnitude of the negative peak velocity in the direction of the tube axis was larger than that of the positive one, and mean velocity in a cycle was very low. This abnormal phasic change of the near-wall velocity may be associated with atherogenesis. The three-dimensional velocity measurement is very useful for the detailed analysis of near-wall velocity patterns.  相似文献   

9.
Numerical analysis of flow phenomena and wall shear stresses in the human carotid artery bifurcation has been carried out using a three-dimensional geometrical model. The primary aim of this study is the detailed discussion of non-Newtonian flow velocity and wall shear stress during the pulse cycle. A comparison of non-Newtonian and Newtonian results is also presented. The applied non-Newtonian behavior of blood is based on measured dynamic viscosity. In the foreground of discussion are the flow characteristics in the carotid sinus. The investigation shows complex flow patterns especially in the carotid sinus where flow separation occurs at the outer wall throughout the systolic deceleration phase. The changing sign of the velocity near the outer sinus wall results in oscillating shear stress during the pulse cycle. At the outer wall of the sinus at maximum diameter level the shear stress ranges from -1.92 N/m2 to 1.22 N/m2 with a time-averaged value of 0.04 N/m2. At the inner wall of the sinus at maximum diameter level the shear stress range is from 1.16 N/m2 to 4.18 N/m2 with a mean of 1.97 N/m2. The comparison of non-Newtonian and Newtonian results indicates unchanged flow phenomena and rather minor differences in the basic flow characteristics.  相似文献   

10.
The pulsatile flow of non-Newtonian fluid in a bifurcation model with a non-planar daughter branch is investigated numerically by using the Carreau-Yasuda model to take into account the shear thinning behavior of the analog blood fluid. The objective of this study is to deal with the influence of the non-Newtonian property of fluid and of out-of-plane curvature in the non-planar daughter vessel on wall shear stress (WSS), oscillatory shear index (OSI), and flow phenomena during the pulse cycle. The non-Newtonian property in the daughter vessels induces a flattened axial velocity profile due to its shear thinning behavior. The non-planarity deflects flow from the inner wall of the vessel to the outer wall and changes the distribution of WSS along the vessel, in particular in systole phase. Downstream of the bifurcation, the velocity profiles are shifted toward the flow divider, and low WSS and high shear stress temporal oscillations characterized by OSI occur on the outer wall region of the daughter vessels close to the bifurcation. Secondary motions become stronger with the addition of the out-of-plane curvature induced by the bending of the vessel, and the secondary flow patterns swirl along the non-planar daughter vessel. A significant difference between the non-Newtonian and the Newtonian pulsatile flow is revealed during the pulse cycle; however, reasonable agreement between the non-Newtonian and the rescaled Newtonian flow is found. Calculated results for the pulsatile flow support the view that the non-planarity of blood vessels and the non-Newtonian properties of blood are an important factor in hemodynamics and may play a significant role in vascular biology and pathophysiology.  相似文献   

11.
12.
Numerical results for axial and secondary flow velocity and pressure in a three-dimensional model of the human carotid siphon have been calculated; the investigations were carried out under physiologically relevant pulsatile flow conditoins. Time-dependent, three-dimensional Navier-Stokes equations were solved numerically by using a special finite element method. The results of the computer simulation presented here concentrate on the secondary motion effect during the pulsatile flow cycle in multiple three-dimensional curvatures.  相似文献   

13.
To analyse the pulsatile flow field and the mechanical stresses in a three-dimensional carotid artery bifurcation model, computer simulation is applied. The approximation of the Navier-Stokes equations uses a pressure correction finite element method. Numerical results are presented for axial and secondary flow velocity and wall shear stresses with special emphasis on the fluid dynamics in the carotid sinus. This region is of major interest because it is affected preferentially by lesions. Detailed local flow studies as carried out here should lead to a further insight into the mechanisms of atherogenesis. The flow conditions used in the study were chosen according to Ku et al. (Arteriosclerosis 5, 293-302, 1985). The results of this numerical analysis agree in the essential features with their experimental results.  相似文献   

14.
In a pulsatile flow model aortic Bj?rk-Shiley Standard, Convex-Concave and Monostrut valves were investigated together with the Hall-Kaster (Medtronic-Hall), St Jude Medical and Starr-Edwards Silastic Ball valve using hot-film anemometry. Three-dimensional visualization of average systolic Reynolds normal stresses (RNS) reflected the design of the valves. Mean average RNS were used for comparison of the fluid dynamic performance along with Velocity Energy Ratio (VER100) and Turbulence Energy Ratio (TER) as a relative turbulence intensity for pulsatile flow. Mean average RNS ranged from 13.2 to 37.6 Nm-2 for all the valves with the highest levels for the Bj?rk-Shiley Standard and Starr-Edwards Ball valve and lowest values for the St Jude Medical valve and with the Hall-Kaster (Medtronic-Hall), Bj?rk-Shiley Convex-Concave and Monostrut valves in between.  相似文献   

15.
Phasic and spatial time-averaged pressure distributions were measured in a 60-deg femoral artery branch model over a large range of branch flow ratios and at physiological Reynolds numbers of about 120 and 700. The results obtained with an in-vivo like flow wave form indicated spatial adverse time average pressure gradients in the branch vicinity which increased in magnitude with branch flow ratio, and the importance of the larger inertial effects at the higher Reynolds numbers. Pressure losses in the branch entrance region were relatively large, and corresponding flow resistances may limit branch flow, particularly at higher Reynolds numbers. The effect of branch flow was to reduce the pressure loss in the main lumen.  相似文献   

16.
A finite element approximation of steady flow in a rigid three-dimensional model of the carotid artery bifurcation is presented. A Reynolds number of 640 and a flow division ratio of about 50/50, simulating systolic flow, was used. To limit the CPU- and I/O-times needed for solving the systems of equations, a mesh-generator was developed, which gives full control over the number of elements into which the bifurcation is divided. A mini-supercomputer, based on parallel and vector processing techniques, was used to solve the system of equations. The numerical results of axial and secondary flow compare favorably with those obtained from previously performed laser-Doppler velocity measurements. Also, the influence of the Reynolds number, the flow division ratio, and the bifurcation angle on axial and secondary flow in the carotid sinus were studied in the three-dimensional model. The influence of the interventions is limited to a relatively small variation in the region with reversed axial flow, more or less pronounced C-shaped axial velocity contours, and increasing or decreasing axial velocity maxima.  相似文献   

17.
The pulsatile flow in an anatomically realistic compliant human carotid bifurcation was simulated numerically. Pressure and mass flow waveforms in the carotid arteries were obtained from an individual subject using non-invasive techniques. The geometry of the computational model was reconstructed from magnetic resonance angiograms. Maps of time-average wall shear stress, contours of velocity in the flow field as well as wall movement and tensile stress on the arterial wall are all presented. Inconsistent with previous findings from idealised geometry models, flow in the carotid sinus is dominated by a strong helical flow accompanied by a single secondary vortex motion. This type of flow is induced primarily by the asymmetry and curvature of the in vivo geometry. Flow simulations have been carried out under the rigid wall assumption and for the compliant wall, respectively. Comparison of the results demonstrates the quantitative influence of the vessel wall motion. Generally there is a reduction in the magnitude of wall shear stress, with its degree depending on location and phase of the cardiac cycle. The region of slow or reversed flow was greater, in both spatial and temporal terms in the compliant model, but the global characteristics of the flow and stress patterns remain unchanged. The analysis of mechanical stresses on the vessel surface shows a complicated stress field. Stress concentration occurs at both the anterior and posterior aspects of the proximal internal bulb. These are also regions of low wall shear stress. The comparison of computed and measured wall movement generally shows good agreement.  相似文献   

18.
Steady and pulsatile flow in a glass model simulating an arterial bifurcation was investigated by flow visualization techniques. Secondary flow generated at the bifurcation has a similar pattern to a vortex, called the horseshoe vortex, produced around a wall-based protuberance in a circular tube. The same flow disturbance was clearly observed during the decelerating phase of pulsatile flow. The vortex produces a stagnation point on the top and bottom wall just upstream from the bifurcation apex. When aluminium dust was suspended in the test fluid perfusing the blood vessel model, particles deposited over an area spreading from the stagnation point to the lateral corners of the bifurcation. Comparison between the present results and topographical patterns of atherosclerosis reported in the literature suggests that it is in such low shear regions that lipid deposition tends to occur most.  相似文献   

19.
A three-dimensional model with simplified geometry for the branched coronary artery is presented. The bifurcation is defined by an analytical intersection of two cylindrical tubes lying on a sphere that represents an idealized heart surface. The model takes into account the repetitive variation of curvature and motion to which the vessel is subject during each cardiac cycle, and also includes the phase difference between arterial motion and blood flowrate, which may be nonzero for patients with pathologies such as aortic regurgitation. An arbitrary Lagrangian Eulerian (ALE) formulation of the unsteady, incompressible, three-dimensional Navier-Stokes equations is employed to solve for the flow field, and numerical simulations are performed using the spectral/hp element method. The results indicate that the combined effect of pulsatile inflow and dynamic geometry depends strongly on the aforementioned phase difference. Specifically, the main findings of this work show that the time-variation of flowrate ratio between the two branches is minimal (less than 5%) for the simulation with phase difference angle equal to 90 degrees, and maximal (51%) for 270 degrees. In two flow pulsatile simulation cases for fixed geometry and dynamic geometry with phase angle 270 degrees, there is a local minimum of the normalized wall shear rate amplitude in the vicinity of the bifurcation, while in other simulations a local maximum is observed.  相似文献   

20.
Kux  J.; Zeiske  E.; Osawa  Y. 《Chemical senses》1988,13(2):257-265
The velocity field of the flow in the olfactory organ of a fish,exemplified by the swordtail Xiphophorus helleri, was investigatedby a three-component laser Doppler velocimetry (LDV) systemin a simulated stationary model flow at an enlarged scale, butconserving hydrodynamic similarity. Both the crossed beam andthe reference beam methods were applied to study the inflowphase. The complexity of the vector field is depicted in sectionalviews by isolines and arrow patterns. The power of the LDV techniqueand model simulation for such investigations is demonstrated.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏