首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
In humans, intra-abdominal pressure (IAP) is elevated during many everyday activities. This experiment aimed to investigate the extent to which increased IAP--without concurrent activity of the abdominal or back extensor muscles--produces an extensor torque. With subjects positioned in side lying on a swivel table with its axis at L3, moments about this vertebral level were measured when IAP was transiently increased by electrical stimulation of the diaphragm via the phrenic nerve. There was no electromyographic activity in abdominal and back extensor muscles. When IAP was increased artificially to approximately 15% of the maximum IAP amplitude that could be generated voluntarily with the trunk positioned in flexion, a trunk extensor moment (approximately 6 Nm) was recorded. The size of the effect was proportional to the increase in pressure. The extensor moment was consistent with that predicted from a model based on measurements of abdominal cross-sectional area and IAP moment arm. When IAP was momentarily increased while the trunk was flexed passively at a constant velocity, the external torque required to maintain the velocity was increased. These results provide the first in vivo data of the amplitude of extensor moment that is produced by increased IAP. Although the net effect of this extensor torque in functional tasks would be dependent on the muscles used to increase the IAP and their associated flexion torque, the data do provide evidence that IAP contributes, at least in part, to spinal stability.  相似文献   

2.
3.
Intra-abdominal pressure (IAP) increases during many tasks and has been argued to increase stability and stiffness of the spine. Although several studies have shown a relationship between the IAP increase and spinal stability, it has been impossible to determine whether this augmentation of mechanical support for the spine is due to the increase in IAP or the abdominal muscle activity which contributes to it. The present study determined whether spinal stiffness increased when IAP increased without concurrent activity of the abdominal and back extensor muscles. A sustained increase in IAP was evoked by tetanic stimulation of the phrenic nerves either unilaterally or bilaterally at 20 Hz (for 5 s) via percutaneous electrodes in three subjects. Spinal stiffness was measured as the force required to displace an indentor over the L4 or L2 spinous process with the subjects lying prone. Stiffness was measured as the slope of the regression line fitted to the linear region of the force-displacement curve. Tetanic stimulation of the diaphragm increased IAP by 27-61% of a maximal voluntary pressure increase and increased the stiffness of the spine by 8-31% of resting levels. The increase in spinal stiffness was positively correlated with the size of the IAP increase. IAP increased stiffness at L2 and L4 level. The results of this study provide evidence that the stiffness of the lumbar spine is increased when IAP is elevated.  相似文献   

4.
The biomechanical effect of tensioning the lumbar fasciae (LF) on the stability of the spine during sagittal plane motion was analysed using a validated finite element model of the normal lumbosacral spine (L4-S1). To apply the tension in the LF along the direction of the fibres, a local coordinate was allocated using dummy rigid beam elements that originated from the spinous process. Up to 10 Nm of flexion and 7.5 Nm of extension moment was applied with and without 20 N of lateral tension in the LF. A follower load of 400 N was additionally applied along the curvature of the spine. To identify how the magnitude of LF tension related to the stability of the spine, the tensioning on the fasciae was increased up to 40 N with an interval of 10 N under 7.5 Nm of flexion/extension moment. A fascial tension of 20 N produced a 59% decrease in angular motion at 2.5 Nm of flexion moment while there was a 12.3% decrease at 10 Nm in the L5-S1 segment. Its decrement was 53 and 9.6% at 2.5 Nm and 10 Nm, respectively, in the L4-L5 segment. Anterior translation was reduced by 12.1 and 39.0% at the L4-L5 and L5-S1 segments under 10 Nm of flexion moment, respectively. The flexion stiffness shows an almost linear increment with the increase in fascial tension. The results of this study showed that the effect of the LF on the stability of the spine is significant.  相似文献   

5.
Understanding spinal kinematics is essential for distinguishing between pathological conditions of spine disorders, which ultimately lead to low back pain. It is of high importance to understand how changes in mechanical properties affect the response of the lumbar spine, specifically in an effort to differentiate those associated with disc degeneration from ligamentous changes, allowing for more precise treatment strategies. To do this, the goals of this study were twofold: (1) develop and validate a finite element (FE) model of the lumbar spine and (2) systematically alter the properties of the intervertebral disc and ligaments to define respective roles in functional mechanics. A three-dimensional non-linear FE model of the lumbar spine (L3-sacrum) was developed and validated for pure moment bending. Disc degeneration and sequential ligament failure were modelled. Intersegmental range of motion (ROM) and bending stiffness were measured. The prediction of the FE model to moment loading in all three planes of bending showed very good agreement, where global and intersegmental ROM and bending stiffness of the model fell within one standard deviation of the in vitro results. Degeneration decreased ROM for all directions. Stiffness increased for all directions except axial rotation, where it initially increased then decreased for moderate and severe degeneration, respectively. Incremental ligament failure produced increased ROM and decreased stiffness. This effect was much more pronounced for all directions except lateral bending, which is minimally impacted by ligaments. These results indicate that lateral bending may be more apt to detect the subtle changes associated with degeneration, without being masked by associated changes of surrounding stabilizing structures.  相似文献   

6.
This study analyzed gait initiation (GI) on inclined surfaces with 68 young adult subjects of both sexes. Ground reaction forces and moments were collected using two AMTI force platforms, of which one was in a horizontal position and the other was inclined by 8% in relation to the horizontal plane. Departing from a standing position, each participant executed three trials in the following conditions: horizontal position (HOR), inclined position at ankle dorsi-flexion (UP), and inclined position at ankle plantar-flexion (DOWN). Statistical parametric mapping analysis was performed over the entire center of pressure (COP) and center of mass (COM) time series. COP excursion did not show significant differences in the medial-lateral (ML) direction in both inclined conditions, but it was greater in the anterior-posterior (AP) direction for both inclined conditions. COP velocities are smaller in discrete portions of GI for the UP and DOWN conditions. COM displacement was greater in the ML direction during anticipatory postural adjustments (APA) in the UP condition, and COM moves faster in the ML direction during APA in the UP condition but slower at the end of GI for both the UP and the DOWN conditions. The COP-COM vector showed a greater angle in the DOWN condition. We observed changes for COP and COM in GI in both the UP and the DOWN conditions, with the latter showing changes for a great extent of the task. Both the UP and the DOWN conditions showed increased COM displacement and velocity. The predominant characteristic during GI on inclined surfaces, including APA, appears to be the displacement of the COM.  相似文献   

7.
Low back mechanics are important to quantify to study injury, pain and disability. As in vivo forces are difficult to measure directly, modeling approaches are commonly used to estimate these forces. Validation of model estimates is critical to gain confidence in modeling results across populations of interest, such as people with lower-limb amputation. Motion capture, ground reaction force and electromyographic data were collected from ten participants without an amputation (five male/five female) and five participants with a unilateral transtibial amputation (four male/one female) during trunk-pelvis range of motion trials in flexion/extension, lateral bending and axial rotation. A musculoskeletal model with a detailed lumbar spine and the legs including 294 muscles was used to predict L4-L5 loading and muscle activations using static optimization. Model estimates of L4-L5 intervertebral joint loading were compared to measured intradiscal pressures from the literature and muscle activations were compared to electromyographic signals. Model loading estimates were only significantly different from experimental measurements during trunk extension for males without an amputation and for people with an amputation, which may suggest a greater portion of L4-L5 axial load transfer through the facet joints, as facet loads are not captured by intradiscal pressure transducers. Pressure estimates between the model and previous work were not significantly different for flexion, lateral bending or axial rotation. Timing of model-estimated muscle activations compared well with electromyographic activity of the lumbar paraspinals and upper erector spinae. Validated estimates of low back loading can increase the applicability of musculoskeletal models to clinical diagnosis and treatment.  相似文献   

8.
A three-dimensional nonlinear finite element model of the lumbar spine was developed. Paired threaded cages and a monosegmental internal spinal fixation device were integrated into the computer model. The model was loaded with such forces as apply during standing, as well as with pure moments in the three main anatomical planes, plus an additional preload. The latter was generated by shortening the distance between the pedicle screws on the longitudinal rod of the fixator. With the exception of torsional loading, an implant appreciably reduces the mobility in the segment concerned. At the loads studied, cages had only a minor impact on the movements and stresses in the adjacent regions, but a strong influence on the stresses in the endplates in contact with them. A preload increases these stresses dramatically. Contact conditions between vertebral body and cages also have a marked effect on the stress distribution in the corresponding vertebral endplate, especially in the case of extension loading. Owing to the preload, maximum stresses were higher for the rigid bond than when contact elements were used.  相似文献   

9.
We formulate and study a new mathematical model of pulmonary hypertension. Based on principles of fluid and elastic dynamics, we introduce a model that quantifies the stiffening of pulmonary vasculature (arteries and arterioles) to reproduce the hemodynamics of the pulmonary system, including physiologically consistent dependence between compliance and resistance. This pulmonary model is embedded in a closed-loop network of the major vessels in the body, approximated as one-dimensional elastic tubes, and zero-dimensional models for the heart and other organs. Increasingly severe pulmonary hypertension is modeled in the context of two extreme scenarios: (1) no cardiac compensation and (2) compensation to achieve constant cardiac output. Simulations from the computational model are used to estimate cardiac workload, as well as pressure and flow traces at several locations. We also quantify the sensitivity of several diagnostic indicators to the progression of pulmonary arterial stiffening. Simulation results indicate that pulmonary pulse pressure, pulmonary vascular compliance, pulmonary RC time, luminal distensibility of the pulmonary artery, and pulmonary vascular impedance are much better suited to detect the early stages of pulmonary hypertension than mean pulmonary arterial pressure and pulmonary vascular resistance, which are conventionally employed as diagnostic indicators for this disease.  相似文献   

10.
11.
During level walking, arm swing plays a key role in improving dynamic stability. In vivo investigations with a telemeterized vertebral body replacement showed that spinal loads can be affected by differences in arm positions during sitting and standing. However, little is known about how arm swing could influence the lumbar spine and hip joint forces and motions during walking. The present study aims to provide better understanding of the contribution of the upper limbs to human gait, investigating ranges of motion and joint reaction forces.A three-dimensional motion analysis was carried out via a motion capturing system on six healthy males and five patients with hip instrumented implant. Each subject performed walking with different arm swing amplitudes (small, normal, and large) and arm positions (bound to the body, and folded across the chest). The motion data were imported in a commercial musculoskeletal analysis software for kinematic and inverse dynamic investigation.The range of motion of the thorax with respect to the pelvis and of the pelvis with respect to the ground in the transversal plane were significantly associated with arm position and swing amplitude during gait. The hip external-internal rotation range of motion statistically varied only for non-dominant limb. Unlike hip joint reaction forces, predicted peak spinal loads at T12-L1 and L5-S1 showed significant differences at approximately the time of contralateral toe off and contralateral heel strike.Therefore, arm position and swing amplitude have a relevant effect on kinematic variables and spinal loads, but not on hip loads during walking.  相似文献   

12.
13.
Widely accepted relationships between gaits (footfall patterns) and center of mass mechanics have been formulated from observations for cursorial mammals. However, sparse data on smaller or more generalized forms suggest a fundamentally different relationship. This study explores locomotor dynamics in one eutherian and five metatherian (marsupials) mammals—all small-bodied (<2 kg) with generalized body plans that utilize symmetrical gaits. Across our sample, trials conforming to vaulting mechanics occurred least frequently (<10% of all trials) while bouncing mechanics was obtained most commonly (60%); the remaining trials represented mixed mechanics. Contrary to the common situation in large mammals, there was no evidence for discrete gait switching within symmetrical gaits as speed increased. This was in part due to the common practice of grounded running. The adaptive advantage of different patterns of center-of-mass motion and their putative energy savings remain questionable in small-bodied mammals.  相似文献   

14.
Effect of an interspinous implant on loads in the lumbar spine.   总被引:3,自引:0,他引:3  
Interspinous process implants are increasingly used to treat canal stenoses. Little information exists about the effects of implant height and stiffness on the biomechanical behavior of the lumbar spine. Therefore, a three-dimensional nonlinear finite element model of the osseoligamentous lumbar spine (L1 to L5) was created with a slightly degenerated disc at L3/L4. An interspinous implant was inserted at that segment. Implants with different heights and stiffnesses were studied. The model was loaded with the upper body weight and muscle forces to simulate walking and 25 degrees extension. Implant forces are influenced strongly by the height and negligibly by the elastic modulus of the implant. Intersegmental rotation at implant level is markedly reduced, while intradiscal pressure is slightly increased. Implant size and stiffness have only a minor effect on intradiscal pressure. The maximum von Mises stress in the vertebral arch is strongly increased by the implant.  相似文献   

15.
There is little information about the influence of bone graft size, position and elasticity on the mechanical behavior of the lumbar spine. Intersegmental motion, intradiscal pressure and stresses in the lumbar spine were calculated using a three-dimensional, nonlinear finite element model which included an internal spinal fixation device and a bone graft. Cross-sectional area, position, and elastic modulus of the graft were varied in this study. Bone grafts, especially very stiff ones, increase stresses on adjacent endplates. Though larger grafts lead to less contact pressure, it is difficult to judge the quality of different bone graft positions. In general, ventral flexion results in lower maximum contact pressure than lateral bending. There is always little intersegmental rotation in the bridged region compared with that of an intact spine.A larger graft with low stiffness should be favored from a mechanical point of view. Patients should avoid lateral bending of the upper body shortly after surgery.  相似文献   

16.
Abstract

Prediction of the biomechanical effects of fusion surgery on adjacent segments is a challenge in computational biomechanics of the spine. In this study, a two-segment L3-L4-L5 computational model was developed to simulate the effects of spinal fusion on adjacent segment biomechanical responses under a follower load condition. The interaction between the degenerative segment (L4-5) and the adjacent segment (L3-4) was simulated using an equivalent follower spring. The spring stiffness was calibrated using a rigid fusion of a completely degenerated disc model at the L4-5 level, resulting in an upper bound response at the adjacent (L3-4) segment. The obtained upper bound equivalent follower spring was used to simulate the upper bound biomechanical responses of fusion of the disc with different degeneration grades. It was predicted that as the disc degeneration grade at the degenerative segment decreased, the effect on the adjacent segment responses decreased accordingly after fusion. The data indicated that the upper bound computational model can be a useful computational tool for evaluation of the interaction between segments and for investigation of the biomechanical mechanisms of adjacent segment degeneration after fusion.  相似文献   

17.
18.
Thirty-four cervical spine segments were harvested from 12 juvenile male baboons and compressed to failure at displacement rates of 5, 50, 500, or 5000 mm/s. Compressive stiffness, failure load, and failure displacement were measured for comparison across loading rate groups. Stiffness showed a significant concomitant increase with loading rate, increasing by 62% between rates of 5 and 5000 mm/s. Failure load also demonstrated an increasing relationship with loading rate, while displacement at failure showed no rate dependence. These data may help in the development of improved pediatric automotive safety standards and more biofidelic physical and computational models.  相似文献   

19.
To characterise the flow of a fluid through a uniform porous medium, the medium may be completely described by its permeability, a measure of flow resistance. Fluid flow in the intertrabecular spaces of cancellous bone has been recognised as an important factor in a number of physical phenomena. In order to investigate the interdependence of permeability, porosity and the structural parameters, we adapted a morphological model and systematically varied its structural parameters. By simulating a viscous Stokes flow regime, we were able to estimate the anisotropic permeability tensor and performed an extensive, stepwise multivariate regression analysis to establish empirical relationships between the morphological parameters and the permeability for the anatomical directions individually. The regression analysis indicated high values of determination coefficients [0.88 < R2 < 0.89 (transversal directions) and R2 = 0.60 (longitudinal direction), porosity-based prediction and R2 = 0.98 for all directions and information presented to the regression model]. We conclude that a pooled set of structural parameters may explain up to 98% of the permeability variability, the regression model predicts permeability values that match experimental data, and a good prediction performance could be achieved by only incorporating the porosity and either the degree of anisotropy (0.89 < R2 < 0.91) or the trabecular spacing predictor (0.96 < R2 < 0.97). These conclusions imply that trabecular thickness and shape parameters only play a minor role in the determination of vertebral trabecular bone permeability. However, a major limitation of the model is that it reflects an idealisation of the real, regionally varying structure of trabecular bone. Therefore, the goodness-of-fit estimates we are presenting should be considered as an upper bound limitation regarding the prediction performance.  相似文献   

20.
A biomechanical study of lateral translation in lumbar spine with human cadavers was performed in order to explore the direction of the force increasing lateral translation and the contributions of discs and facet joints to lateral translation. Whole lumbar spines from 12 fresh cadavers were attached to a specially designed loading apparatus whose five cables simulated the muscles of the trunk without restricting natural movement. Three-dimensional positions of each vertebra were recorded with position-sensitive detectors. Force in the anterolateral direction increased the lateral translation more than force in the posterolateral direction. Lateral translation was increased to a significantly greater extent when the facet joints were removed than when the discs were removed at L4-5 at the levels of shear loading applied in this study.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号