首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The center of rotation (COR) of the upper cervical spine (UCS) is an important biomechanical landmark that is used to determine upper neck moment, particularly when evaluating injury risk in the automotive environment. However, neither the location of the UCS CORs nor the occipital condyles (OCs), which are frequently the referenced landmark for UCS CORs, have been measured with respect to known cranial landmarks. This study determines the CORs using pure bending (+/-3.5 N m), 3D digitization, and image analysis. Landmarks digitized included the OCs, external auditory meatus (EAM), infraorbital foramen, zygion, nasion, and the foramen magnum. The centroid of each occipital condylar surface (area 301+/-29.8 mm(2); length 25.4+/-3.2 mm) was located 18.4 mm posterior, 54.4 mm medial, and 31.0 mm inferior of the EAM. The UCS CORs were distinct: On average, OC-C1 CORs (22.5 mm posterior and 22.6 mm inferior to the left EAM) were superior and more posterior of OCs; C1-C2 CORs (7.4 mm posterior and 46.7 mm inferior to the left EAM) were inferior and more anterior of OC; and OC-C2 CORs (17.0 mm posterior and 33.1 mm inferior to the left EAM) were aligned with OC. There was a statistically significant difference between the percentage of UCS rotation in C1-C2 and OC-C1; 45% of the flexion and 71% of the extension occurred in OC-C1. Details of an anatomical variant with two pairs of distinct condylar surfaces are also presented.  相似文献   

2.
3.
The facet joint contributes to the normal biomechanical function of the spine by transmitting loads and limiting motions via articular contact. However, little is known about the contact pressure response for this joint. Such information can provide a quantitative measure of the facet joint's local environment. The objective of this study was to measure facet pressure during physiologic bending in the cervical spine, using a joint capsule-sparing technique. Flexion and extension bending moments were applied to six human cadaveric cervical spines. Global motions (C2-T1) were defined using infra-red cameras to track markers on each vertebra. Contact pressure in the C5-C6 facet was also measured using a tip-mounted pressure transducer inserted into the joint space through a hole in the postero-inferior region of the C5 lateral mass. Facet contact pressure increased by 67.6 ± 26.9 kPa under a 2.4 Nm extension moment and decreased by 10.3 ± 9.7 kPa under a 2.7 Nm flexion moment. The mean rotation of the overall cervical specimen motion segments was 9.6 ± 0.8° and was 1.6 ± 0.7° for the C5-C6 joint, respectively, for extension. The change in pressure during extension was linearly related to both the change in moment (51.4 ± 42.6 kPa/Nm) and the change in C5-C6 angle (18.0 ± 108.9 kPa/deg). Contact pressure in the inferior region of the cervical facet joint increases during extension as the articular surfaces come in contact, and decreases in flexion as the joint opens, similar to reports in the lumbar spine despite the difference in facet orientation in those spinal regions. Joint contact pressure is linearly related to both sagittal moment and spinal rotation. Cartilage degeneration and the presence of meniscoids may account for the variation in the pressure profiles measured during physiologic sagittal bending. This study shows that cervical facet contact pressure can be directly measured with minimal disruption to the joint and is the first to provide local pressure values for the cervical joint in a cadaveric model.  相似文献   

4.
Translational vertebral motion during functional tasks manifests itself in dynamic loci for center of rotation (COR). A shift of COR affects moment arms of muscles and ligaments; consequently, muscle and joint forces are altered. Based on posture- and level-specific trends of COR migration revealed by in vivo dynamic radiography during functional activities, it was postulated that the instantaneous COR location for a particular joint is optimized in order to minimize the joint reaction forces. A musculoskeletal multi-body model was employed to investigate the hypotheses that (1) a posterior COR in upright standing and (2) an anterior COR in forward flexed posture leads to optimized lumbar joint loads. Moreover, it was hypothesized that (3) lower lumbar levels benefit from a more superiorly located COR.The COR in the model was varied from its initial position in posterior-anterior and inferior-superior direction up to ±6 mm in steps of 2 mm. Movement from upright standing to 45° forward bending and backwards was simulated for all configurations. Joint reaction forces were computed at levels L2L3 to L5S1. Results clearly confirmed hypotheses (1) and (2) and provided evidence for the validity of hypothesis (3), hence offering a biomechanical rationale behind the migration paths of CORs observed during functional flexion/extension movement. Average sensitivity of joint force magnitudes to an anterior shift of COR was +6 N/mm in upright and −21 N/mm in 30° forward flexed posture, while sensitivity to a superior shift in upright standing was +7 N/mm and −8 N/mm in 30° flexion. The relation between COR loci and joint loading in upright and flexed postures could be mainly attributed to altered muscle moment arms and consequences on muscle exertion. These findings are considered relevant for the interpretation of COR migration data, the development of numerical models, and could have an implication on clinical diagnosis and treatment or the development of spinal implants.  相似文献   

5.

The research focussed on analysing structural and mechanical properties in the intervertebral disc (IVD), caused by long-term cyclic loading. Spinal motion segments were divided into two groups: the control (C), and the group in which it was analysed the impact of posterior column in the load-bearing system of the spine—specimens with intact posterior column (IPC) and without posterior column (WPC). To evaluate the structural and mechanical changes, the specimens were tested with simulation of 100,000 compression-flexion load cycles after which it was performed macroscopic analysis. Mechanical properties of the annulus fibrosis (AF) from the anterior and posterior regions of the IVD were tested at the uniaxial tension test. The stiffness coefficient values were statistically 32% higher in the WPC group (110 N/mm) than in the IPC (79 N/mm). The dynamics of increase in this parameter does not correspond with the course of decrease in height loss. WPC segments revealed clear structural changes that mainly involve the posterior regions of the IVD (bulging and delamination with the effect of separation of collagen fibre bundles). Pathological changes also caused decreases in the value of stress in the AF. The greatest changes in the stress value about group C (7.43 ± 4.49 MPa) were observed in the front part of the fibrous ring, where this value was for IPC 4.49 ± 4.78 MPa and WPC 2.56 ± 1.01 MPa. The research indicates that the applied load model allows simulating damage that occurs in pathological IVD. And the posterior column’s presence affects this change’s dynamics, structural and mechanical properties of AF.

  相似文献   

6.
Kim K  Kim YH  Lee S 《Journal of biomechanics》2011,44(8):1614-1617
It has been reported that the center of rotation of each vertebral body is located posterior to the vertebral body center. Moreover, it has been suggested that an optimized follower load (FL) acts posterior to the vertebral body center. However, the optimal position of the FL with respect to typical biomechanical characteristics regarding spinal stabilization, such as joint compressive force, shear force, joint moment, and muscle stress, has not been studied. A variation in the center of rotation of each vertebra was formulated in a three-dimensional finite element model of the lumbar spine with 117 pairs of trunk muscles. Then, the optimal translation of the FL path connecting the centers of rotations was estimated by solving the optimization problem that was to simultaneously minimize the compressive forces, the shear forces, and the joint moments or to minimize the cubic muscle stresses. An upright neutral standing position and a standing position with 200N in both hands were considered. The FL path moved posterior, regardless of the optimization criteria and loading conditions. The FL path moved 5.0 and 7.8mm posterior in upright standing and 4.1mm and 7.0mm posterior in standing with 200N in hands for each optimization scheme. In addition, it was presented that the optimal FL path may have advantages in comparison to the body center FL path. The present techniques may be important in understanding the spine stabilization function of the trunk muscles.  相似文献   

7.
Posteroanterior stiffness of the lumbar spine is influenced by factors, including trunk muscle activity and intra-abdominal pressure (IAP). Because these factors vary with breathing, this study investigated whether stiffness is modulated in a cyclical manner with respiration. A further aim was to investigate the relationship between stiffness and IAP or abdominal and paraspinal muscle activity. Stiffness was measured from force-displacement responses of a posteroanterior force applied over the spinous process of L2 and L4. Recordings were made of IAP and electromyographic activity from L4/L2 erector spinae, abdominal muscles, and chest wall. Stiffness was measured with the lung volume held at the extremes of tidal volume and at greater and lesser volumes. Stiffness at L4 and L2 increased above base-level values at functional residual capacity (L2 14.9 N/mm and L4 15.3 N/mm) with both inspiratory and expiratory efforts. The increase was related to the respiratory effort and was greatest during maximum expiration (L2 24.9 N/mm and L4 23.9 N/mm). The results indicate that changes in trunk muscle activity and IAP with respiratory efforts modulate spinal stiffness. In addition, the diaphragm may augment spinal stiffness via attachment of its crural fibers to the lumbar vertebrae.  相似文献   

8.
Under fast dynamic loading conditions (e.g. high-energy impact), the load rate dependency of the intervertebral disc (IVD) material properties may play a crucial role in the biomechanics of spinal trauma. However, most finite element models (FEM) of dynamic spinal trauma uses material properties derived from quasi-static experiments, thus neglecting this load rate dependency. The aim of this study was to identify hyperelastic material properties that ensure a more biofidelic simulation of the IVD under a fast dynamic compressive load. A hyperelastic material law based on a first-order Mooney-Rivlin formulation was implemented in a detailed FEM of a L2-L3 functional spinal unit (FSU) to represent the mechanical behavior of the IVD. Bony structures were modeled using an elasto-plastic Johnson-Cook material law that simulates bone fracture while ligaments were governed by a viscoelastic material law. To mimic experimental studies performed in fast dynamic compression, a compressive loading velocity of 1 m/s was applied to the superior half of L2, while the inferior half of L3 was fixed. An exploratory technique was used to simulate dynamic compression of the FSU using 34 sets of hyperelastic material constants randomly selected using an optimal Latin hypercube algorithm and a set of material constants derived from quasi-static experiments. Selection or rejection of the sets of material constants was based on compressive stiffness and failure parameters criteria measured experimentally. The two simulations performed with calibrated hyperelastic constants resulted in nonlinear load-displacement curves with compressive stiffness (7335 and 7079 N/mm), load (12,488 and 12,473 N), displacement (1.95 and 2.09 mm) and energy at failure (13.5 and 14.7 J) in agreement with experimental results (6551 ± 2017 N/mm, 12,411 ± 829 N, 2.1 ± 0.2 mm and 13.0 ± 1.5 J respectively). The fracture pattern and location also agreed with experimental results. The simulation performed with constants derived from quasi-static experiments showed a failure energy (13.2 J) and a fracture pattern and location in agreement with experimental results, but a compressive stiffness (1580 N/mm), a failure load (5976 N) and a displacement to failure (4.8 mm) outside the experimental corridors. The proposed method offers an innovative way to calibrate the hyperelastic material properties of the IVD and to offer a more realistic simulation of the FSU in fast dynamic compression.  相似文献   

9.
The intervertebral disc (IVD) is the joint of the spine connecting vertebra to vertebra. It functions to transmit loading of the spine and give flexibility to the spine. It composes of three compartments: the innermost nucleus pulposus (NP) encompassing by the annulus fibrosus (AF), and two cartilaginous endplates connecting the NP and AF to the vertebral body on both sides. Discogenic pain possibly caused by degenerative intervertebral disc disease (DDD) and disc herniations has been identified as a major problem in our modern society. To study possible mechanisms of IVD degeneration, in vitro organ culture systems with live disc cells are highly appealing. The in vitro culture of intact bovine coccygeal IVDs has advanced to a relevant model system, which allows the study of mechano-biological aspects in a well-controlled physiological and mechanical environment. Bovine tail IVDs can be obtained relatively easy in higher numbers and are very similar to the human lumbar IVDs with respect to cell density, cell population and dimensions. However, previous bovine caudal IVD harvesting techniques retaining cartilaginous endplates and bony endplates failed after 1-2 days of culture since the nutrition pathways were obviously blocked by clotted blood. IVDs are the biggest avascular organs, thus, the nutrients to the cells in the NP are solely dependent on diffusion via the capillary buds from the adjacent vertebral body. Presence of bone debris and clotted blood on the endplate surfaces can hinder nutrient diffusion into the center of the disc and compromise cell viability. Our group established a relatively quick protocol to "crack"-out the IVDs from the tail with a low risk for contamination. We are able to permeabilize the freshly-cut bony endplate surfaces by using a surgical jet lavage system, which removes the blood clots and cutting debris and very efficiently reopens the nutrition diffusion pathway to the center of the IVD. The presence of growth plates on both sides of the vertebral bone has to be avoided and to be removed prior to culture. In this video, we outline the crucial steps during preparation and demonstrate the key to a successful organ culture maintaining high cell viability for 14 days under free swelling culture. The culture time could be extended when appropriate mechanical environment can be maintained by using mechanical loading bioreactor. The technique demonstrated here can be extended to other animal species such as porcine, ovine and leporine caudal and lumbar IVD isolation.  相似文献   

10.
对后方入路SDRS内固定加BAK植骨融合治疗腰椎滑脱症的临床应用研究进行初步报告,探讨此项技术的手术要点和早期临床效果。自2001年1月至2001年8月,对13例腰椎滑脱患者行后方入路椎体间BAK植骨融合、SDRS内固定。随访6个月-14个月,平均9.1个月。结合临床症状改善程度和X线片上植骨副合、复位程度综合进行疗效评定。结果:疗效优3例,良9例,差1例,优良率92.3%。结果表明从一个切口入路行椎体间BAK植骨融合、SDRS内固定术,能对前柱和后柱同时起稳定作用,有利于滑脱的复位和维持正常的腰椎前凸,符合腰椎的生物力学要求。  相似文献   

11.
Lumbar vertebrae are complicated in structure and function. The purpose of this study was to investigate the in-vivo motion characteristics of different portions of the lumbar vertebrae during functional activities. Motion of L2, L3 and L4 was reproduced using a combined dual fluoroscopic and MR imaging technique during flexion–extension and left–right twisting of the trunk. The ranges of motion (ROM) of the proximal vertebra with respect to the distal one at 3 representative locations: the center of the vertebral body, the center of the spinal canal and the tip of the spinous process were measured. Centers of rotation (COR) of the vertebrae were then determined by calculation of the points of zero motion in 2D sagittal and transverse planes. During flexion–extension, the center of the vertebral body moved less than 0.6 mm, while the tip of the spinous process moved less than 7.5 mm in the sagittal plane. The CORs of both L23 (L2 with respect to L3) and L34 were located inside the vertebral body, at a distance about one-third the length of the vertebral body from the posterior edge. During left–right twisting, the center of the vertebral body moved less than 1.0 mm, while the tip of the spinous process moved less than 1.6 mm in the transverse plane. The CORs of both L23 and L34 were located approximately 30 mm anterior to the front edge of the vertebral body. The results of this study may be used to define the ideal locations for surgical placement of the disc prosthesis, thus help improve the prosthesis design and surgical treatment of various pathological conditions.  相似文献   

12.
Evaluation of the loads on lumbar intervertebral discs (IVD) is critically important since it is closely related to spine biomechanics, pathology and prosthesis design. Non-invasive estimation of the loads in the discs remains a challenge. In this study, we proposed a new technique to estimate in vivo loads in the IVD using a subject-specific finite element (FE) model of the disc and the kinematics of the disc endplates as input boundary conditions. The technique was validated by comparing the forces and moments in the discs calculated from the FE analyses to the in vitro experiment measurements of three corresponding lumbar discs. The results showed that the forces and moments could be estimated within an average error of 20%. Therefore, this technique can be a promising tool for non-invasive estimation of the loads in the discs and may be extended to be used on living subjects.  相似文献   

13.
The lack of standardization in experimental protocols for unconfined compression tests of intervertebral discs (IVD) tissues is a major issue in the quantification of their mechanical properties. Our hypothesis is that the experimental protocols influence the mechanical properties of both annulus fibrosus and nucleus pulposus. IVD extracted from bovine tails were tested in unconfined compression stress-relaxation experiments according to six different protocols, where for each protocol, the initial swelling of the samples and the applied preload were different. The Young's modulus was calculated from a viscoelastic model, and the permeability from a linear biphasic poroviscoelastic model. Important differences were observed in the prediction of the mechanical properties of the IVD according to the initial experimental conditions, in agreement with our hypothesis. The protocol including an initial swelling, a 5% strain preload, and a 5% strain ramp is the most relevant protocol to test the annulus fibrosus in unconfined compression, and provides a permeability of 5.0 ± 4.2e(-14)m(4)/N[middle dot]s and a Young's modulus of 7.6 ± 4.7 kPa. The protocol with semi confined swelling and a 5% strain ramp is the most relevant protocol for the nucleus pulposus and provides a permeability of 10.7 ± 3.1 e(-14)m(4)/N[middle dot]s and a Young's modulus of 6.0 ± 2.5 kPa.  相似文献   

14.
There is a clear relationship between lumbar spine loading and back musculoskeletal disorders in manual materials handling. The incidence of back disorders is greater in women than men, and for similar work demands females are functioning closer to their physiological limit. It is crucial to study loading on the spine musculoskeletal system with actual handlers, including females, to better understand the risk of back disorders. Extrapolation from biomechanical studies conducted on unexperienced subjects (mainly males) might not be applicable to actual female workers. For male workers, expertise changes the lumbar spine flexion, passive spine resistance, and active/passive muscle forces. However, experienced females select similar postures to those of novices when spine loading is critical. This study proposes that the techniques adopted by male experts, male novices, and females (with considerable experience but not categorized as experts) impact their lumbar spine musculoskeletal systems differently. Spinal loads, muscle forces, and passive resistance (muscle and ligamentous spine) were predicted by a multi-joint EMG-assisted optimization musculoskeletal model of the lumbar spine. Expert males flexed their lumbar spine less (avg. 21.9° vs 30.3–31.7°) and showed decreased passive internal moments (muscle avg. 8.9% vs 15.9–16.0%; spine avg. 4.7% vs 7.1–7.8%) and increased active internal moments (avg. 72.9% vs 62.0–63.9%), thus producing a different impact on their lumbar spine musculoskeletal systems. Experienced females sustained the highest relative spine loads (compression avg. 7.3 N/BW vs 6.2–6.4 N/BW; shear avg. 2.3 N/BW vs 1.7–1.8 N/BW) in addition to passive muscle and ligamentous spine resistance similar to novices. Combined with smaller body size, less strength, and the sequential lifting technique used by females, this could potentially mean greater risk of back injury. Workers should be trained early to limit excessive and repetitive stretching of their lumbar spine passive tissues.  相似文献   

15.
目的:探讨股四头肌腱的生物力学特性,为其能否应用于临床前交叉韧带(ACL)重建提供实验依据.方法:取32例新鲜尸体的1cm宽股四头肌腱,按其解剖结构分为两柬:股直肌、股内、外侧肌腱舍为A束,股中问肌腱为B束,用游标卡尺测量两束的宽度及厚度,然后将两束置于电子万能试验机上分别测其生物力学指标.结果:A 束厚度为4.39±1.72mm,宽度为8.19±1.18mm,生物力学强度为685.67±227.09N,抗拉强度为17.00±3.48Mpa;B束厚度为3.06±1.47mm,宽度为7.10±2.03mm,生物力学强度为435.04±205.80N,抗拉强度为13.16±4.02Mpa.A束生物力学强度与ACL比较,差异有统计学意义(p<0.05);B束生物力学强度与ACL比较,差异有统计学意义(p<0.05).结论:股四头肌腱的生物力学性能不能满足ACL双束重建的要求,其在临床上应用于ACL双束重建的价值有待于进一步的深入研究.
Abstract:
Objective: To investigate the biomechanics of the quadrieeps tendon and to provide theoretical basis for double-bundle reeonstruction of anterior cruciate iigament(ACL). Methods: 32 quadriceps tendons (width lena) taken from fresh cadaver were dissected into 2 bundles according to the anatomy, one bundle including rectus femoris, vastus medialis and vastus lateralis was named A bundle and the other was named B bundle. The width and thickness of the A and B bundle were detected respectively with a Vernier caliper and the biomechanics were determined by WDW-30 election universal testing machine. Results: The thickness, width, ultimate load and ultimate tensile strength of bundle A were 4.39± 1.72mm, 8.19± 1.18mm, 685.67± 227.09 N and 17.00± 3.48 Mpa respectively, while for bundle B,which were 3.06± 1.47 ram, 7.10± 2.03mm: 435.04±205.80 N and 13.16± 4.02 Mpa. There was difference between bundle A and the ACL (p<0.05). Conclusion: The ultimate load ofbundle A was much lower than the the ACL and bundle Bwas also lower than the ACL.  相似文献   

16.
Ultimate strength of the lumbar spine in flexion--an in vitro study   总被引:2,自引:0,他引:2  
The ultimate strength in flexion of 16 lumbar functional spinal units (FSU) was determined. The specimens were exposed to a combined static load of bending and shearing in the sagittal plane until overt rupture occurred (simulated flexion-distraction injuries). The biomechanical response of the FSU was measured with a force and moment platform. Mechanical displacement gauges were used to measure vertical displacements (flexion angulation) of the specimens. Photographs were taken after each loading step for determination of horizontal displacements and the centre of rotation. The lumbar FSU could resist a combination of bending moment and shear force of 156 Nm and 620 N respectively, before complete disruption occurred. The tension force acting on the posterior structures was 2.8 kN. The flexion angulation just before failure was 20 degrees and the anterior horizontal displacement between the upper and lower vertebrae was 9 mm. The centre of rotation was located in the posterior part of the lower vertebral body. The bone mineral content in the vertebrae appeared to be a good predictor of ultimate strength of the lumbar FSU. Knowledge of the biomechanical response of the lumbar spine under different static traumatic loads is a first step to better understand the injury mechanisms of the spine in traffic accidents.  相似文献   

17.
Changes in spinal posture between the erect and flexed positions were calculated using angular measurements from lateral photographs and radiographs of ten adult male subjects. For photographic measurements, the thoracolumbar vertebral column was modelled as either a single segment or as three segments. In the three-segment model, there was a non-significant correlation between the decrease in lumbar concavity and intervertebral motion. In addition, there was a non-significant negative correlation between the increase in thoracic convexity and lumbar motion determined radiographically. In the single-segment model, the decrease in angulation between the thoracolumbar spine and pelvis was a good representation of lumbar spine flexion as determined by the mean lumbar intervertebral angular change. Therefore, modelling the thoracolumbar vertebral column as a single segment allowed better estimation of lumbar intervertebral angular change during flexion than a three-segment model. The results indicate that large range dynamic motion of the lumbar vertebral column can be represented using photographic analysis of the positions of three easily identified anatomical landmarks: the anterior superior iliac spine, posterior superior iliac spine and the spinous process of the first thoracic vertebra.  相似文献   

18.
目的:探讨股四头肌腱的生物力学特性,为其能否应用于临床前交叉韧带(ACL)重建提供实验依据。方法:取32例新鲜尸体的1cm宽股四头肌腱,按其解剖结构分为两束:股直肌、股内、外侧肌腱合为A束,股中间肌腱为B束,用游标卡尺测量两束的宽度及厚度,然后将两束置于电子万能试验机上分别测其生物力学指标。结果:A束厚度为4.39±1.72mm,宽度为8.19±1.18mm,生物力学强度为685.67±227.09N,抗拉强度为17.00±3.48Mpa;B束厚度为3.06±1.47mm,宽度为7.10±2.03mm,生物力学强度为435.04±205.80N,抗拉强度为13.16±4.02Mpa。A束生物力学强度与ACL比较,差异有统计学意义(p〈0.05);B束生物力学强度与ACL比较,差异有统计学意义(p〈0.05)。结论:股四头肌腱的生物力学性能不能满足ACL双束重建的要求,其在临床上应用于ACL双束重建的价值有待于进一步的深入研究。  相似文献   

19.
Understanding changes in lumbar spine (LS) angles and intervertebral disc (IVD) behavior in end-range positions in healthy subjects can provide a basis for developing more specific LS models and comparing people with spine pathology. The purposes of this study are to quantify 3D LS angles and changes in IVD characteristics with end-range positions in 3 planes of motion using upright MRI in healthy people, and to determine which intervertebral segments contribute most in each plane of movement. Thirteen people (average age = 24.4 years, range 18–51 years; 9 females; BMI = 22.4 ± 1.8 kg/m2) with no history of low back pain were scanned in an upright MRI in standing, sitting flexion, sitting axial rotation (left, right), prone on elbows, prone extension, and standing lateral bending (left, right). Global and local intervertebral LS angles were measured. Anterior-posterior length of the IVD and location of the nucleus pulposus was measured. For the sagittal plane, lower LS segments contribute most to change in position, and the location of the nucleus pulposus migrated from a more posterior position in sitting flexion to a more anterior position in end-range extension. For lateral bending, the upper LS contributes most to end-range positions. Small degrees of intervertebral rotation (1–2°) across all levels were observed for axial plane positions. There were no systematic changes in IVD characteristics for axial or coronal plane positions.  相似文献   

20.
This project aimed to compare gross anatomical measures and biomechanical properties of single lamellae from the annulus fibrosus of ovine and porcine lumbar vertebrae, and bovine tail vertebrae. The morphology of the vertebrae of these species differ significantly both from each other and from human, yet how these differences alter biomechanical properties is unknown. Geometric parameters measured in this study included: 1) absolute and relative intervertebral (IVD) and vertebral body height and 2) absolute and relative intervertebral disc (IVD) anterior‐posterior (AP) and medial‐lateral (ML) widths. Single lamella tensile properties included toe‐region stress and stretch ratio, stiffness, and tensile strength. As expected, the bovine tail IVD revealed a more circular shape compared with both the ovine and porcine lumbar IVD. The bovine tail also had the largest IVD to vertebral body height ratio (due to having the highest absolute IVD height). Bovine tail lamellae were also found to be strongest and stiffest (in tension) while ovine lumbar lamellae were weakest and most compliant. Histological analysis revealed the greatest proportion of collagen in the bovine corroborating findings of increased strength and stiffness. The observed differences in anatomical shape, connective tissue composition, and tensile properties need to be considered when choosing an appropriate model for IVD research. J. Morphol. 277:244–251, 2016. © 2015 Wiley Periodicals, Inc.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号