首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A sensitive and highly selective liquid chromatography-tandem mass spectrometry (LC-MS-MS) method was developed to determine nimodipine in human plasma. The analyte and internal standard nitrendipine were extracted from plasma samples by n-hexane-dichloromethane-isopropanol (300:150:4, v/v/v), and chromatographed on a C(18) column. The mobile phase consisted of methanol-water-formic acid (80:20:1, v/v/v). Detection was performed on a triple quadrupole tandem mass spectrometer by selected reaction monitoring (SRM) mode via atmospheric pressure chemical ionization (APCI) source. The method has a limit of quantification of 0.24 ng/ml. The linear calibration curves were obtained in the concentration range of 0.24-80 ng/ml. The intra- and inter-day precisions were lower than 4.4% in terms of relative standard deviation (R.S.D.), and the accuracy ranged from 0.0 to 5.8% in terms of relative error (RE). This validated method was successfully applied for the evaluation of pharmacokinetic profiles of nimodipine tablets administered to 18 healthy volunteers.  相似文献   

2.
A rapid, sensitive and accurate liquid chromatographic-tandem mass spectrometric method is described for the determination of tamsulosin in dog plasma. Tamsulosin was extracted from plasma using a mixture of hexane-ethyl acetate (2:1, v/v) and separated on a C18 column interfaced with a triple quadrupole tandem mass spectrometer. The mobile phase consisting of a mixture of methanol, water and formic acid (80:20:1, v/v/v) was delivered at a flow rate of 0.5 ml/min. Atmospheric pressure chemical ionization (APCI) source was operated in positive ion mode. Selected reaction monitoring (SRM) mode using the transitions of m/z 409-->m/z 228 and m/z 256-->m/z 166.9 were used to quantify tamsulosin and the internal standard, respectively. The linearity was obtained over the concentration range of 0.1-50.0 ng/ml for tamsulosin and the lower limit of quantitation was 0.1 ng/ml. For each level of QC samples, inter- and intra-run precision was less than 5.0 and 4.0% (relative standard deviation (R.S.D.)), respectively, and accuracy was within +/-0.3% (relative error (R.E.)). This method was successfully applied to pharmacokinetic study of a tamsulosin formulation product after oral administration to beagle dogs.  相似文献   

3.
A highly sensitive and selective liquid chromatography-tandem mass spectrometry (LC-MS-MS) method was developed to determine meloxicam of low concentration in human plasma. After a simple sample preparation procedure by one-step protein precipitation with methanol, meloxicam and the internal standard piroxicam were chromatographed on a Zorbax SB C(18) column. The mobile phase consisted of acetonitrile-water-formic acid (80:20:0.2, v/v/v). Detection was performed on a triple quadrupole tandem mass spectrometer by selected reaction monitoring (SRM) mode via electrospray ionization (ESI) source. The method had a lower limit of quantification of 0.10 ng/ml. The calibration curve was demonstrated to be linear over the concentration range of 0.10-50.0 ng/ml. The assay was specific, accurate (percentage deviations from nominal concentrations were within +/-2.5%), precise (intra- and inter-day relative standard deviation (R.S.D.) <7%). The validated method was successfully applied to the determination of meloxicam in human plasma collected up to 180 h after a transdermal administration of 30 mg meloxicam for evaluation of the pharmacokinetics.  相似文献   

4.
A rapid and sensitive LC-MS-MS method for the determination of huperzine A in dog plasma using huperzine B as internal standard has been developed and validated. The analyte and internal standard were extracted from plasma using n-hexane-dichloromethane-2-propanol (300:150:15, v/v/v), chromatographed on a C(18) column (5 microm, 50 mm x 4.6 mm i.d.) with a mobile phase consisting of acetonitrile-methanol-10mM ammonium acetate (35:40:25, v/v/v), and detected using a tandem mass spectrometer with a TurboIonSpray ionization interface. The run time was only 2 min. The assay was linear over the concentration range 0.05-20 ng/ml and intra- and inter-day precision over this range were <5.3% with good accuracy. The limit of detection in plasma was 0.01 ng/ml. The method was successfully applied to define plasma concentration-time curves of huperzine A in dogs after the last dose of an intramuscular injection (10 microg/kg per day for 15 days) of a sustained-release formulation of huperzine A.  相似文献   

5.
A rapid and sensitive method to determine colchicine in human plasma by liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been developed. Colchicine and the internal standard (I.S.), tegafur, were extracted from the matrix with n-hexane:dichloromethane:isopropanol (300:150:15, v/v/v) and separated by reversed-phase high-performance liquid chromatography (HPLC) using formic acid:10 mM ammonium acetate:methanol (1:49:75, v/v/v) as the mobile phase in a run time of 2.5 min. Detection was carried out by electrospray positive ionization mass spectrometry in the multiple-reaction monitoring (MRM) mode. The assay was linear in the concentration range 0.050-10 ng/ml with intra- and inter-day precision (as relative standard deviation (R.S.D.)) of <2 and <7%, respectively. The method was applied to a pharmacokinetic study of colchicine in healthy volunteers given an oral dose of 2.0 mg.  相似文献   

6.
A selective and sensitive high performance liquid chromatography-electrospray ionisation-mass spectrometry method has been developed for the determination of balofloxacin (BLFX) in human plasma. The sample preparation was a liquid-liquid extraction, and chromatographic separation was achieved with an Agilent ZORBAX 300SB C18 2.1 mm x 150 mm column using a mobile phase comprised of methanol-water (10 mM CH(3)COONH(4), pH 3.0)=40:60 (v/v). Standard curves were linear (r=0.9992) over the concentration range of 0.03-3 microg/ml and had good accuracy and precision. The within- and between-batch precisions were within 10% relative standard deviation (R.S.D.). The limit of detection (LOD) was 0.02 microg/ml. The validated HPLC-electrospray ionization (ESI)-MS method has been used successfully to study balofloxacin pharmacokinetics in healthy volunteers.  相似文献   

7.
A rapid and sensitive method for the simultaneous determination of paracetamol and guaifenesin in human plasma was developed and validated, using high-performance liquid chromatographic separation with tandem mass spectrometric detection. After extracted from plasma samples by diethyl ether-dichloromethane (3:2, v/v), the analytes and internal standard osalmide were chromatographed on a C18 column. Detection was performed on a triple quadrupole tandem mass spectrometer by selected reaction monitoring (SRM) mode via atmospheric pressure chemical ionization (APCI). The method was linear in the concentration range of 0.05-20.0 microg/ml for paracetamol and 5.0-2000.0 ng/ml for guaifenesin. The intra- and inter-day precision was within 14% for both paracetamol and guaifenesin. The assay accuracy was within +/-2.4% for the analytes. This is the first assay method described for the simultaneous determination of paracetamol and guaifenesin in plasma using one chromatographic run. The method was successfully employed in a pharmacokinetic study after an oral administration of a multicomponent formulation, containing 650 mg paracetamol, 200 mg guaifenesin, 60 mg pseudoephedrine and 20 mg dextrorphan.  相似文献   

8.
Oxaliplatin ([(1R,2R)-1,2-cyclohexanediamine-N,N']oxalato(2-)-O,O'-platinum) is the first platinum drug with significant activity for metastatic colon cancer. The analysis of oxaliplatin has previously almost exclusively been based on the determination of the platinum content in plasma or ultrafiltrate using flameless atomic absorption spectroscopy (FAAS) or inductively coupled plasma mass spectrometry (ICPMS). A new method for quantitative determination of the free fraction of the intact drug in blood ultrafiltrate is presented here. Blood was ultrafiltrated centripetally at 4 degrees C and the ultrafiltrate was analyzed by liquid chromatography. Oxaliplatin was separated on a Hypercarb column using a mobile phase of methanol/succinic acid buffer pH 7.0 (9/1, v/v). Post-column derivatization was performed by adding N,N-diethyldithiocarbamate in methanol and with microwave heating of a Teflon tubing. The derivative was quantified by photometric detection at 344 nm. The coefficient of variation of standard blood samples was 4.9 and 2.5% at 0.100 and 1.00 microg/ml, respectively. The limit of quantitation was 0.04 microg/ml.  相似文献   

9.
A sensitive and selective liquid chromatographic-tandem mass spectrometric (LC-MS/MS) method was developed for the determination of cefdinir in human plasma. After a simple protein precipitation using trichloracetic acid, the post-treatment samples were applied to a prepacked RP18 Waters SymmetryShield column interfaced with a triple quadrupole tandem mass spectrometer. Positive electrospray ionization was employed as the ionization source. The mobile phase consisted of methanol-water-formic acid (25:75:0.075, v/v/v). The analyte and I.S. cefaclor were both detected by the use of selected reaction monitoring mode. The method was linear in the concentration range of 5-2,000 ng/ml. The lower limit of quantification was 5 ng/ml. The intra- and inter-day relative standard deviation across three validation runs over the entire concentration range was less than 4.3%. The accuracy determined at three concentrations (36, 360 and 1,800 ng/ml for cefdinir) ranged from 99.6 to 106.7% in terms of recovery. The chromatographic run time for each plasma sample was less than 3 min. The method herein described was successfully applied for the evaluation of pharmacokinetic profiles of cefdinir capsule in 12 healthy volunteers.  相似文献   

10.
This paper describes a rapid and sensitive analytical method for the quantitation of iptakalim, a novel antihypertensive drug, in human plasma. The method is based on liquid chromatography-tandem mass spectrometry (LC-MS/MS) using sildenafil as internal standard. Sample preparation involved liquid-liquid extraction with dichloromethane-diethyl ether (2:3, v/v) in a basic environment. Chromatography was carried out on an amino column with a mobile phase consisting of acetonitrile-water (55:45, v/v, water containing 0.5% formic acid). Detection employed electrospray ionization (ESI) tandem mass spectrometry in the multiple-reaction-monitoring (MRM) mode. The assay was linear in the concentration range of 0.5-100 ng/ml with a lower limit of quantitation (LLOQ) of 0.5 ng/ml. Intra- and inter-day precision (R.S.D.) were <4.5% and <12.0%, respectively and the accuracy (R.E.) was in the range +/-5%. The method was successfully applied to a single oral dose pharmacokinetic study in human volunteers.  相似文献   

11.
A fast and selective HPLC-MS-MS method was established to determine L-threonate in human plasma and urine. Plasma and urine samples were extracted by protein precipitation and diluted with water, then chromatographed on an YMC J'Sphere C(18) column with methanol-acetonitrile-10mM ammonium acetate (20:5:75, v/v) as mobile phase, and at a flow rate of 0.2 ml/min. Detection was performed on a triple-quadrupole tandem mass spectrometer using negative electrospray ionization (ESI). Multiple reactions monitoring (MRM) was used and L-threonate was quantified by monitoring the ion transition of m/z 134.5-->74.7. The linear calibration curves of L-threonate in plasma and urine were obtained over the concentration range of 0.25-50 microg/ml and 2.5-500 microg/ml, respectively. Lower limit of quantitation was 0.25 and 2.5 microg/ml, respectively. Accuracy was within 85-115%, and intra- and inter-batch precision (R.S.D.%) were within +/-15%. The method proved to be accurate and specific, and was applied to the pharmacokinetic study of L-threonate in Chinese healthy subjects.  相似文献   

12.
A liquid chromatography-electrospray ionization-mass spectrometry (LC-ESI-MS) assay for the determination of bencycloquidium bromide (BCQB) in rat plasma was firstly developed and validated. After addition of 1-ethyl-bencycloquidium bromide as an internal standard (I.S.), the plasma samples were deproteinized with methanol and the supernatant was assayed by LC-ESI-MS. Chromatographic separation was achieved with a Hanbon Lichrospher 5-C18 column. The mobile phase consisted of methanol-40 mM ammonium acetate buffer-formic acid (75:25:0.25, v/v/v) and delivered at the flow rate of 1.0 ml/min. LC-ESI-MS was carried out on a single quadrupole mass spectrometer using electrospray ionization (ESI) and positive selected-ion monitoring (SIM). Target ions were monitored at [M](+)m/z 330.2 for BCQB and [M] (+)m/z 344.2 for I.S. Calibration curve was linear over the range of 3-1500 ng/ml. The lower limit of quantification (LLOQ) was 3.0 ng/ml. The intra- and inter-run relative standard deviations (R.S.D.%) of the assay were less than 7.1 and 12.3%, respectively. The accuracy determined at the concentrations of 3.0, 100.0, 500.0 and 1500 ng/ml for BCQB were within +/-15.0%. The established method has been applied successfully to study the pharmacokinetics of BCQB in rats after intranasal administration.  相似文献   

13.
Existing methods to determine neferine, a bisbenzylisoquinline alkaloid, either have no internal standard or lack selectivity, or take longer time. Here an improved reverse-phase high-performance liquid chromatographic (RP-HPLC) method was established in biological samples. The extraction recovery was 90.9% for neferine at concentration level of 0.2 microg/ml and 77.7% for dauricine (the internal standard) at 5 microg/ml in dog plasma, respectively. The linear quantification range of the method was 25-2000 ng/ml in dog plasma, with linear correlation coefficients greater than 0.999. The intra-day and inter-day relative standard deviations (R.S.D.s) for neferine at 50, 200 and 1000 ng/ml levels in dog plasma fell in the range of 3.0-5.4% and 4.3-9.5%, respectively. The RP-HPLC method was successfully applied to a pharmacokinetics study, in which experimental dogs received a single dose of neferine (5 mg/kg i.v. or 10 mg/kg p.o.). The pharmacokinetic result was presented.  相似文献   

14.
A sensitive and specific liquid chromatography electrospray ionization mass spectrometry (LC-ESI-MS) method has been developed and validated for the identification and quantification of lipoic acid (LA) in human plasma. LA and the internal standard, naproxen, were extracted from a 500 microl plasma sample by one-step deproteination using acetonitrile. Chromatographic separation was performed on a Zorbax SB-C(18) Column (100 mmx3.0mm i.d. with 3.5 microm particle size) with the mobile phase consisting of acetonitrile and 0.1% acetic acid (pH 4, adjusted with ammonia solution) (65:35, v/v), and the flow rate was set at 0.3 ml/min. Detection was performed on a single quadrupole mass spectrometer by selected ion monitoring (SIM) mode via electrospray ionization (ESI) source. The method was linear over the concentration range of 5-10,000 ng/ml for LA. The intra- and inter-day precisions were less than 7% and accuracy ranged from -7.87 to 9.74% at the LA concentrations tested. The present method provides a relatively simple and sensitive assay with short turn-around time. The method has been successfully applied to a clinical pharmacokinetic study of LA in 10 healthy subjects.  相似文献   

15.
A selective and sensitive high performance liquid chromatography-electrospray ionization mass spectrometry method has been developed for the determination of tolterodine tartrate in human plasma. With oxybutynin as internal standard, tolterodine tartrate was extracted from plasma with n-hexane: isopropanol (95:5, v/v). The organic layer was evaporated and the residue was redissolved in mobile phase comprised of acetonitrile-water (10 mM CH3COONH4, pH 3.0)=50:50 (v/v). An aliquot of 10 microl was chromatographically analyzed on a prepacked Shimadzu Shim-pack VP-ODS C18 column (150 mmx2.0 mm I.D.) by means of selected-ion monitoring (SIM) mode mass spectrometry. Standard curves were linear (r=0.9993) over the concentration range of 0.1-30.0 ng/ml and had good accuracy and precision. The within- and between-batch precisions were within 10% relative standard deviation. The limit of detection (LOD) was 0.05 ng/ml. The validated LC-ESI-MS method has been used successfully to study tolterodine tartrate pharmacokinetic, bioavailability and bioequivalence in 20 healthy male volunteers.  相似文献   

16.
A liquid chromatographic-tandem mass spectrometric method (LC-MS/MS) for the determination of ulifloxacin, the active metabolite of prulifloxacin, in human plasma is described. After sample preparation by protein precipitation with methanol, ulifloxacin and ofloxacin (internal standard) were chromatographically separated on a C(18) column using a mobile phase consisting of methanol, water and formic acid (70:30:0.2, v/v/v) at a flow rate of 0.5 ml/min and then were detected using MS/MS by monitoring their precursor-to-product ion transitions, m/z 350-->m/z 248 for ulifloxacin and m/z 362-->m/z 261 for ofloxacin, in selected reaction monitoring (SRM) mode. Positive electrospray ionization was used for the ionization process. The linear range was 0.025-5.0 microg/ml for ulifloxacin with a lower limit of quantitation of 0.025 microg/ml. Within- and between-run precision was less than 6.6 and 7.8%, respectively, and accuracy was within 2.0%. The recovery ranged from 92.1 to 98.2% at the concentrations of 0.025, 0.50 and 5.0 microg/ml. Compared with the reported LC method, the present LC-MS/MS method can directly determine the ulifloxacin in human plasma without any need of derivatization. The present method has been successfully used for the pharmacokinetic studies of a prulifloxacin formulation product after oral administration to healthy volunteers.  相似文献   

17.
The method for separation and determination of dexamethasone sodium phosphate (DexP) in cochlear perilymph fluid (CPF) of cavy was developed using HPLC with ultraviolet (UV) monitoring and electrospray ionization/mass spectrometry (ESI/MS) identification. The quantitative determination of DexP in CPF was achieved by HPLC with UV detection at 245 nm. The separation was carried out on a Phenomenex ODS(3) column ( 250 mm x 4.6 mm i.d., 5 microm) with the mobile phase of acetonitrile-5mmol/l ammonium acetate (23:77 (v/v)) at a flow rate of 1.0 ml/min. DexP was baseline separated from the matrices of CPF blanks within 15 min. The linearity ranged from 0.5 to 50 microg/ml. The limit of detection was 0.10 microg/ml. The recovery ranged from 98.5 to 100.8%. The relative standard deviations (R.S.D.s) of intra- and inter-day peak area were between 0.7-1.3 and 1.2-3.5%, respectively. Both full scan MS and MS2 of DexP with positive and negative polarity were obtained and elucidated. The specific ions were chosen to characterize DexP in the CPF sample. Using the proposed HPLC-UV-ESI/MS method, the concentration of DexP in CPF samples after both vein and middle ear injections were determined, and the relationships between concentration and time were obtained. This method offered reference data for clinical investigation of DexP to cure ear diseases.  相似文献   

18.
A rapid, sensitive and selective liquid chromatography-tandem mass spectrometric (LC-MS/MS) method for the determination of baicalein, baicalin, oroxylin A and wogonin, Scutellaria baicalensis active components in rat plasma was developed. After liquid-liquid extraction with 2-(3,4-dimethoxy-phenyl)-5,7-dihydroxy-chromen-4-one as internal standard, baicalein, baicalin, oroxylin A and wogonin were eluted from an Atlantis C(18) column within 7 min with isocratic mobile phase consisting of methanol and 0.1% formic acid (60:40, v/v). The analytes were detected using an electrospray ionization tandem mass spectrometry in the multiple reaction monitoring (MRM) mode. The standard curves were linear (r=1.000) over the concentration ranges of 5-500 ng/ml for baicalein, wogonin and oroxylin A and 5-5000 ng/ml for baicalin. The coefficients of variation and relative errors of baicalein, wogonin, oroxylin A and baicalin for intra- and inter-assay at three or four quality control (QC) levels were 0.8-6.1% and -4.0 to 5.8%, respectively. The lower limits of quantification for baicalein, wogonin, oroxylin A and baicalin were 5ng/ml using 50 microl of plasma sample. This method was successfully applied to the pharmacokinetic study of baicalein, baicalin, wogonin and oroxylin A after an intravenous administration of Scutellariae radix extract to male Sprague-Dawley rats.  相似文献   

19.
A rapid, sensitive and selective hydrophilic interaction liquid chromatography-tandem mass spectrometric (HILIC-MS/MS) method for the determination of levosulpiride in human plasma was developed. Levosulpiride and internal standard, tiapride were extracted from human plasma with ethyl acetate at pH 11 and analyzed on an Atlantis HILIC silica column with the mobile phase of acetonitrile-ammonium formate (190 mM, pH 3.0) (94:6, v/v). The analytes were detected using an electrospray ionization tandem mass spectrometry in the multiple-reaction-monitoring mode. The standard curve was linear (r = 0.999) over the concentration range of 1.00-200 ng/ml. The lower limit of quantification for levosulpiride was 1.00 ng/ml using 100 microl plasma sample. The coefficient of variation and relative error for intra- and inter-assay at three quality control (QC) levels were 3.8-9.1 and -2.9 to -0.1%, respectively. The recoveries of levosulpiride ranged from 80.5 to 87.4%, with that of tiapride (internal standard) being 84.6%. This method was successfully applied to the pharmacokinetic study of levosulpiride in humans.  相似文献   

20.
A rapid, selective and sensitive liquid chromatography-tandem mass spectrometry (LC-MS-MS) method was developed and validated for determination of ibutilide in human plasma. The analyte and internal standard sotalol were extracted from plasma samples by liquid-liquid extraction, and separated on a C(18) column, using acetonitrile-water-10% butylamine-10% acetic acid (80:20:0.07:0.06, v/v/v/v) as the mobile phase. Detection was performed on a triple-quadrupole tandem mass spectrometer by multiple reaction monitoring (MRM) mode via TurboIonSpray ionization (ESI). Linear calibration curves were obtained in the concentration range of 20-10,000 pg/ml, with a lower limit of quantitation of 10 pg/ml. The intra- and inter-day precision values were below 8% and accuracy was within +/-3% at all three QC levels. The method was utilized to support clinical pharmacokinetic studies of ibutilide in healthy volunteers following intravenous administration.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号