首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
人类免疫缺陷病毒1/2型抗体检测酶联免疫试剂盒的研制   总被引:2,自引:0,他引:2  
采用二聚体合成肽(HIV-1gp41、gp120、p24和HIV-2gp36)包被酶标板条制备成固相抗原,与鼠抗人IgG单克隆抗体酶标记物、底物TMB及阴阳性参考血清配套制备成HIV抗体EIA试剂盒,专供检测人血清或血浆HIV1/2抗体之用。以荷兰、韩国及万泰试剂作为对照,用该试剂盒对检定所的Panel标准及献血员15550例(其中HCV抗体阳性128例,HBsAg阳性46例)进行检测,四种试剂对检定所Panel标准的13份阳性血清均呈阳性反应,28份阴性血清均为阴性;献血员15550例,四种试剂对其中1份血清均呈阳性反应,经Westernblot试验证实为阴性,四种试剂的阴性检出率均为99.99%。连续制备三批试剂经中国药品生物制品检定所检定,所检项目全部合格;同时委托检定所进行临床考核,47份阳性血清全部呈阳性反应,150份阴性血清全部为阴性。说明该试剂盒具有很好的敏感性和特异性。  相似文献   

2.
To investigate the mechanism leading to an oriented immobilization of recombinant proteins onto synthetic copolymers, five genetically modified HIV-1 p24 capsid proteins (RH24, RH24A4K2, RH24R6, RH24R4K2, and RH24K6) were tested for their efficiency to covalently bind to maleic anhydride-alt-methyl vinyl ether (MAMVE) and N-vinyl pyrrolidone-alt-maleic anhydride (NVPMA) copolymers. These proteins contain, at their C-termini, tags differing in cationic and/or reactive amino acids density. We demonstrated that an increase of the charge and amine density in the tag enhances the coupling yield, the most efficient tag being a six lysine one. The reactivity of the proteins depends directly on the reactivity of the tag, and this led us to conclude that the tag was the site where the covalent grafting with the polymer occurred. Thus, design of such tags provides a new efficient and versatile method allowing oriented immobilization of recombinant proteins onto copolymers.  相似文献   

3.
A new subtype (MVP-5180) of human immunodeficiency virus type 1 (HIV-1) was isolated from a Cameroonian AIDS patient. MVP-5180 was grown in several human T-cell lines and the monocytic U937 line. MVP-5180 DNA could not be amplified by nested primer PCR with conventional env primers and could be only very faintly amplified with gag and pol primers. Most German, Ivoirian, and Malawian anti-HIV-1 sera reacted faintly or moderately with Env proteins in an MVP-5180 immunoblot, whereas some Cameroonian sera reacted strongly. Of HIV-1-infected Cameroonians, 8% were identified by serological methods as infected with MVP-5180; 7% were positive when MVP-5180-specific PCR env primers were used. DNA sequence analysis of MVP-5180 showed that its genetic organization was that of HIV-1, with 65% similarity to HIV-1 and 56% similarity to HIV-2 consensus sequences. The env gene of MVP-5180 had similarities to HIV-1 and HIV-2 of 53 and of 49%, respectively. V3 loop analysis identified a crown of Gly-Pro-Met-Arg by using cloned DNA and Gly-Pro-Leu-Arg by using PCR-amplified DNA, neither of which configuration has been described for other HIV strains. In an analysis of relationships, MVP-5180 occupied a position distant to all other HIV-1 strains, including the chimpanzee simian immunodeficiency virus type 1 SIVcpz and the Uganda virus U455, and closer to the HIV-1/HIV-2 divergence node. MVP-5180, together with another Cameroonian isolate, ANT-70, constitutes a group subtype O of the most divergent HIV-1 isolates yet identified. Characterization of MVP-5180 is important for understanding the natural history of the primate immunodeficiency viruses and for the development of vaccines and diagnostics.  相似文献   

4.
Human cell lines were infected with different strains of human immunodeficiency virus types 1 and 2 (HIV-1 and HIV-2) as well as with a simian immunodeficiency virus SIVmac isolate and used as targets in an antibody-dependent cellular cytotoxicity (ADCC) assay. Sera from HIV-1- or HIV-2-infected subjects provided the antibody, and lymphocytes from normal donors provided the effector cells. About 60% of HIV-1 antibody-positive sera mediated ADCC when tested against any given HIV-1 isolate-infected target cell (human T-cell lymphotropic virus type IIIB, B40, A2587), and about 75% of HIV-2 antibody-positive sera mediated ADCC when tested against target cells infected with HIV-2 isolates (lymphadenopathy-associated virus type 2 and SBL-6669) or simian immunodeficiency virus from macaques. Within each type, individual sera showed different reactivity patterns, and the probability that a serum was ADCC positive was higher when it was tested against several strains. When the ADCC reactivity of sera against different strains was compared, diversity as detected by ADCC appeared to be greater among HIV-1 strains than among HIV-2 strains. For HIV-1, 54 to 67% of the sera gave concordant ADCC reactions, whereas for HIV-2 and SIVmac, 91% of the sera gave concordant results. Almost no strain-specific differences were seen between SBL-6669 and lymphadenopathy-associated virus type 2. As we determined previously, HIV-1 and HIV-2 did not cross-react in ADCC. The results indicated that HIV-1 and HIV-2 antibody-positive sera mediate both strain- and type-specific ADCC. HIV-2 antibody-positive sera seem to mediate ADCC with broader reactivity and to a higher frequency compared with HIV-1 antibody-positive sera.  相似文献   

5.
Toxoplasma gondii ME49 infections are typically diagnosed by serological tests. However, serological diagnosis of RH strain-induced toxoplasmosis remains unknown. In order to develop seradiagnosis of above 2 kinds of infections, we generated recombinant virus-like particles (VLPs) displaying the T. gondii rhoptry protein 4 (ROP4) and evaluated their potential in T. gondii ME49 or RH strain infection diagnostics. Mice were orally infected with either the tachyzoites of T. gondii (RH) or cysts of T. gondii (ME49) at various dosages, and sera were collected at regular intervals. ELISA-based serological tests were performed to assess IgG, IgM, and IgA antibody responses against ROP4 VLP antigen and tissue lysate antigen (TLA). Compared to TLA, IgG, IgM, and IgA levels to ROP4 VLP antigen were significantly higher in the sera of T. gondii RH-infected mice 1 and 2 week post-infection (PI). T. gondii-specific IgG antibody was detected at 1, 2, 4, and 8 week PI in the T. gondii ME49-infected mice with infection dose-dependent manner. These results indicated that the ROP4 VLP antigen was highly sensitive antigens detecting T. gondii RH and ME49 antibodies at an early stage.  相似文献   

6.
HIV-1 Gag protein precursor p55, and its processed products, p17, p24, and p15 were overproduced in Escherichia coli and purified to near homogeneity. To study the antigenic properties and the potentiality as the diagnostic and prognostic reagents, varying amounts of the purified Gag proteins were dotted onto the polyvinylidene difluoride membrane and reacted with 40 sera of HIV-1-infected individuals (35 AC, 1 ARC, and 4 AIDS patients) and 10 sera of normal healthy donors. p55 reacted with 40 (100%) sera of HIV-1 carriers, while p17, p24, and p15 reacted with 37 (92.5%), 35 (87.5%) and 34 (85%) of the 40 sera of HIV-1 carriers, respectively. On the whole, the reaction of p55 was especially strong and that of p15 was the weakest. p55 showed the strongest reaction among the four Gag proteins with all specimens, and it showed a positive reaction with a carrier serum with which none of the processed Gag proteins showed a positive reaction. Therefore, p55 is the most useful antigen among the four Gag proteins for detection of the Gag antibodies and may even be one of the most useful antigens for the diagnosis of HIV-1 infection.  相似文献   

7.
The serological study of 20 sera, showing atypical reaction with HIV-1 in the immunoblotting assay, for the presence of HIV-2 infection revealed some cases of this infection among Africans who had arrived to the USSR from Western Africa (5 cases) and Burundi (1 case); besides, in 1 case HIV-2 infection was detected in a Soviet female citizen having had many sexual partners among foreigners.  相似文献   

8.
Antibodies against human immunodeficiency virus type-1 (HIV-1) in samples from blood donors are commonly detected by various enzyme-linked immunosorbent assays (ELISA) and by confirmatory tests, e.g., "Western blot" or immunofluorescence tests. Immunoblot reactivity, which is directed only towards the HIV-1 core proteins p 18, p 24 and p 55, may represent false-positive reactions. Out of 125,000 blood donations, 140 were repeatably HIV-1 antibody reactive by ELISA; of these, 20 were doubtful positive sera with isolated p 18 and/or p 24 bands in the HIV-1 confirmatory assay. Antibodies to HIV-2 are known to cross-react with these HIV-1 core proteins. We therefore assayed the 20 sera by immunofluorescence and immunoblotting for the presence of antibodies to HIV-2. None of these doubtful HIV-1 antibody positive blood donor sera was found to have antibodies to HIV-2.  相似文献   

9.
To establish a sensitive and specific antibody assay, potent antigenic proteins encoded by human herpesvirus 8 (HHV8) were studied. Fifteen recombinant HHV8-encoded proteins were produced as glutathione S-transferase fusion proteins. The sera from AIDS-associated Kaposi's sarcoma (KS) patients reacted with four proteins encoded by open reading frames (ORFs) K8.1, 59, 65, and 73 in a Western blot assay. An enzyme-linked immunosorbent assay (ELISA) using these four proteins as antigens (mixed-antigen ELISA) revealed that all 26 sera derived from KS patients (24 with and 2 without human immunodeficiency virus infection) became positive for anti-HHV8 antibodies. The presence of HHV8 was demonstrated in 14 (1. 4%) of 1,004 sera from the Japanese general population and 10 (1.9%) of 527 sera from patients without HHV8-associated diseases. The presence of immunoglobulin G (IgG) and IgM antibodies against HHV8 examined further by the mixed-antigen ELISA and Western blotting revealed IgG antibody in all ELISA-positive sera, while IgM antibody against ORF K8.1 was absent. These data suggest that the ORF 73 and 65 proteins are potent antigens for a sensitive serological assay.  相似文献   

10.
Presently, the diagnosis of virus infections is based mainly on serological assays. Although polymerase chain reaction (PCR) and enzyme-linked immunosorbent assay (ELISA) have been increasingly used for the diagnosis of such viral infections, the risk of transfusion-transmitted blood-borne viruses remains. Furthermore, PCR and ELISA are expensive and time-consuming, and sometimes cause falsepositive or false-negative results. Therefore, a rapid, accurate and cost-effective diagnostic procedure is needed. We subjected plasma from individuals infected with human immunodeficiency virus type-1 (HIV-1), the causative agent of acquired immune deficiency syndrome (AIDS), as well as plasma from uninfected individuals as a control to near-infrared (NIR) spectroscopy, which may provide a rapid diagnostic method for HIV-1 infection without using any reagent. NIR spectra in the 600-1,000 nm region for plasma from pre-serologically HIV-1-infected individuals and healthy donors were subjected to partial least squares (PLS) regression analysis and leave-out cross-validation to develop a multivariate model to estimate the concentration of HIV-1. Simultaneously, the same plasma samples were examined for HIV-1 p24 by ELISA. The results obtained by the NIR spectroscopy model for HIV-1 yielded a good correlation with those obtained by the reference method (HIV-1 p24 ELISA). These results suggest that NIR spectroscopy using plasma could provide a rapid, accurate, cost-effective tool for large-scale diagnosis of HIV-1 infection.  相似文献   

11.
Microbial activity acts as primer in the self combustion process of solid recovered fuels (SRF) during their storage or transport. Thus, EU gave mandate to the European Committee for Standardization (CEN) to develop biological methods, (i.e. respirometric method) able to assess the risk of potential self combustion of SRF. Real Dynamic Respiration Index (RDRI) was chosen as official method, and a validation procedure was requested, to assure the quality of the results, when the method is applied for official purpose, i.e. repeatability and reproducibility detection. Two SRF coming from full-scale plants were analyzed for RDRI by three laboratories in six replicates. Results indicated a good precision of the method proposed in agreement with other biological methods, i.e. relative standard deviations of repeatability ranged from 16.7% to 17.8%, and a relative standard deviations of reproducibility ranged from 17.5% to 23.9%.  相似文献   

12.
The authors report 2 biochip platforms on gold manufactured by either nanoscale biotinylated self-assembled architectures to streptavidin surface or proteins containing free NH(2) groups to N-hydroxysuccinimide (NHS)-activated surfaces and investigated the potential application of tumor necrosis factor-alpha (TNFalpha) serodiagnosis of hemophagocytic lymphohistiocytosis (HLH). Interactions of TNFalpha antigen and TNFalpha antibody on the biochips were optimized using an indirect immunofluorescence method. Variation coefficients were 1.87% to 4.56% on the streptavidin biochip and 5.03% to 8.64% on the NHS biochip. The correlation coefficients (r) in TNFalpha and TNFalpha antibody assays in HLH patients between the 2 biochip formats were 0.9623 and 0.9386 and the concordance frequencies were 92.2% and 96.1%, respectively. To detect plasma TNFalpha-receptor complexes (TNFR1 and R2) in HLH, a biochip assay strategy was developed. Plasma levels of TNFalpha, TNFalpha antibody, and TNFalpha-receptor complexes (TNFR1 and R2) were detected in plasmas from 42 HLH cases using streptavidin biochips. Frequencies of the biomarkers in the plasmas were 40.5% (17/42) for TNFalpha, 30.9% (13/42) for TNFalpha antibody, 28.6% (12/42) for TNFalpha-receptor 1 complex, and 26.1% (11/42) for TNFalpha-receptor 2 complex, respectively. The streptavidin biochip format was more sensitive than the NHS surface and was demonstrated to be a valuable tool to identify individual biomarker molecules and molecular complexes in sera and cell lysates and to track therapeutic progress of patients.  相似文献   

13.
A novel and rapid approach to quantify chloride concentration in sweat for early detection of cystic fibrosis (CF) is shown in this work. Disposable screen-printed sensor (SPS) devices capable to induce sweat and measure the chloride concentration are presented. Pilocarpine, which was forced into de skin by means of iontophoresis, has been used to stimulate the sweat glands. Chloride concentration has been directly measured on the skin by potentiometry. The performance of the devices has been tested in synthetic samples, obtaining good agreement with the Nernst equation. Sensors reproducibility has been analyzed in terms of residual standard deviation (RSD), obtaining a value of 8% (n=6 and alpha=0.05). Finally, the application of these sensors in several volunteers has been carried out. The results were compared with the method generally used in hospitals, obtaining deviations minor than 8%.  相似文献   

14.
目的研制灵敏度和特异性高的检测实验猴血清中T淋巴细胞趋向性病毒-1型(STLV-1型)/E体的双抗原夹心ELISA(dsELISA)检测试剂盒。方法采用经原核表达系统表达并纯化的人T淋巴细胞白血病病毒-1型(HTLV-1型)的Env蛋白作为包被用抗原,建立了检测STLV-1的dsELISA诊断方法。通过优化反应条件和筛选试剂,确定了dsELISA诊断试剂盒的相关条件,并经敏感性、特异性和重复性试验考查该试剂盒质量。结果试剂盒特异性好,批内重复试验变异系数(CV)〈7%,批间重复试验CV〈10%。对200份猴血清进行随机检测,与国际公认的诊断试剂盒(美国BioReliance公司)的符合率为97%。结论本试剂盒可初步应用于临床上实验猴STLV-1型抗体的检测。  相似文献   

15.
Particulate glycoproteins lacking sialic acid, such as desialylated enveloped viruses, readily activate complement through the alternative pathway. Human immunodeficiency virus type 1 (HIV-1) contains two heavily glycosylated and partially sialylated envelope glycoproteins: a surface gp120 and a transmembrane gp41. The abilities of naturally glycosylated HIV-1 and glycosylation-modified HIV-1 to interact with the complement system were examined with a biological assay which measured the binding of whole virus particles to cells expressing CR2 (CD21), the complement receptor found naturally in abundance on follicular dendritic cells and immature B cells. HIV-1 IIIB was synthesized in the presence or absence of the mannosidase II inhibitor, swainsonine, to give rise to high-mannose-type, nonsialylated, nonfucosylated carbohydrate moieties. The virus also was treated with neuraminidase or endo-beta-galactosidase to remove terminal sialic acids. An enzyme immunoassay specific for HIV-1 p24 core protein was used to quantitate the amount of virus bound to cell surfaces. Virus particles incubated with 1:3-diluted, fresh HIV-1-negative human serum as a source of complement readily bound to MT-2 (CD4+ CR2+) and Raji-3 (CD4- CR2+) cells but not to CEM (CD4+ CR2-) cells, suggesting that the virus bound to CR2 independently of CD4. Compared with heat-inactivated or C3-deficient sera, fresh complement increased binding by as much as 62 times for naturally glycosylated virus, and 5 times more than this for glycosylation-modified virus. Similar observations were made with freshly isolated, non-mitogen-stimulated peripheral blood mononuclear cells. Additional evidence that HIV-1 bound to CR2 independently of CD4 was provided by the fact that binding was blocked by monoclonal antibody OKB7 (anti-CR2) but not by OKT4a (anti-CD4). Also, the virus bound to transfected K562 cells (CD4-) which expressed recombinant human CR2 but did not bind to untransfected K562 cells. Results obtained with complement component-deficient sera indicated that binding required the alternative complement pathway. Raji-3 and transfected K562 cells could not be infected with HIV-1 in the presence of complement, suggesting that utilization of CR2 as a receptor in the absence of CD4 does not allow virus entry. The demonstration of CR2 as a receptor for HIV-1 in the presence of complement, together with the ability to enhance binding by desialylation, provides new insights into mechanisms of HIV-1-induced immunity and immunopathogenesis.  相似文献   

16.
应用斑点金免疫渗滤试验(dotimmunogoldfiltrationassay,DIGFA)建立了一种同步快速检测四种抗HIV-1/2IgG抗体的HIV诊断试纸。通过基因工程技术在大肠杆菌中表达了5种HIV抗原蛋白片段(P24,GP41,GP36,GP120V3,GP120C)。这5种抗原蛋白首先被固定在硝酸纤维素膜上,然后滴加待测血清,其中的病毒抗体通过免疫反应与抗原结合,再加胶体金标记的葡萄球菌蛋白A(SPA),待其渗过膜片后,洗涤,即可形成肉眼可见的红色斑点。用已确证的21份HIV阳性血清(其中包括1份HIV-1标准阳性血清和1份HIV-2标准阳性血清)和30份阴性血清进行了试验,结果表明该快速检测方法与ELISA方法无显著差异。该检测方法不需任何仪器,仅凭肉眼即可判定结果,整个检测过程不超过5分钟。与传统的的ELISA法相比,具有方便快速,成本低廉,应用范围广等优点。同时,此HIV快速诊断试纸可以同步检测并区分针对HIV-1和HIV-2感染的不同检测标志物(抗P24、GP41、GP120和GP36抗体),这对提高快速检测的灵敏度和准确性,以及对判断HIV感染者是否临近或已进入AIDS期有着较高的应用价值。  相似文献   

17.
目的:构建HIV-1重组腺病毒疫苗并初步鉴定其免疫原性。方法:用Adeno-XExpressionSystem试剂盒将HIV—lgagpol基因片段插入到腺病毒载体上,通过脂质体介导将获得的重组腺病毒质粒Adeno—X-gagpol转染至293细胞,使之自主包装成有感染活性的重组腺病毒tad—gagpol,用western-blotting法鉴定其表达情况;用CsCl密度梯度离心法纯化该重组腺病毒,以5×10^8 pfu/mL的滴度lmL单次免疫小鼠,15天后测小鼠体液免疫效果。结果:克隆序列与设计相符,重组腺病毒疫苗能稳定表达gag—pol蛋白,体液免疫中检测出抗p55和p24的特异性抗体。结论:HIV—lgagpol重组腺病毒构建成功,具有一定的体液免疫原性。  相似文献   

18.
The reactivity of antibodies with dimeric and monomelic peptide antigens was compared by ELISA. A panel of highly purified synthetic peptides of HIV-1 representing defined regions, 598–609 and 524 533 (fusion domain) of gp41 and 306–320 of gpl20, were used as antigens in the ELISA. These peptides were selected and synthesized taking into account the level of sequence conservation of various strains and hydrophilicity. The analysis included sera from 52 HIV-1 infected individuals and 53 HIV-1 negative controls. Both peptides from gp41 were found to be particularly immunoreactive with sera from HIV-1 infected individuals. The frequency of reactivity to the selected peptide from gp120 (V3 loop) in infected individuals was 82%. An interesting observation was that the dimeric peptide antigens had a detection rate more than 4-fold higher than the monomeric antigens. We found that lower levels of antibodies could be detected with dimeric antigens. The peptides reacted with few sera other than HIV-1 positive sera. These results implicate the potential dimeric peptide antigens to be utilized in the serodiagnosis of HIV-1 infection.  相似文献   

19.
The objective of this study was expression of a recombinant fusion protein p24-gp41 to gain a proper folding pattern of the proteins which could be recognized by specific antibodies against human immunodeficiency virus type 1 (HIV-1) for development of a reliable serodiagnostic kit. Serodiagnostic method using enzyme-linked immunosorbent assay (ELISA) with the expressed recombinant fusion protein p24-gp41 was carried out to test the sensitivity and specificity of the protein using human sera and various reference panels from Boston Biomedica Inc. (BBI). The level of the expression was determined to be 30% and the final recovery from fermentation and purification process was calculated as 80 mg/L with more than 98% purity. The developed ELISA assay was demonstrated to have 100 and 99.5% sensitivity and specificity, respectively, detecting anti-HIV-1 antibody using 900 positive and 10,000 negative human sera. The developed assay showed reliable results in comparison with other reference HIV ELISA kits using various BBI panels as well. In conclusion, the recombinant fusion protein p24-gp41 was expressed and used to develop a serodiagnostic kit for screening of the HIV-1 with high sensitivity (100%) and specificity (99.5%) which could be useful for screening large groups of blood donors.  相似文献   

20.
Summary In this study we present a postembedding on-grid immunogold labelling procedure for the ultrastructural localization of the HIV-1 core protein p24. HIV-1 infected cells were fixed in 0.1% glutaraldehyde, incompletely dehydrated and embedded in LR White or in Lowicryl K4M. Antigenic sites were detected by incubation of ultrathin sections with primary mouse monoclonal antibody anti-HIV-1 p24, followed by the secondary antibody goat anti-mouse IgG coupled to 10nm gold particles. Antigenicity of p24 was found to withstand the applied fixation and was shown to be preserved in LR White as well as in Lowicryl. The described procedure permits the uncomplicated and easy detection of p24 in HIV-1 infected cells and tissues.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号