Background

Public health research on sedentary behavior (SB) in youth has heavily relied on accelerometers. However, it has been limited by the lack of consensus on the most accurate accelerometer cut-points as well as by unknown effects caused by accelerometer position (wrist vs. hip) and output (single axis vs. multiple axes). The present study systematically evaluates classification accuracy of different Actigraph cut-points for classifying SB using hip and wrist-worn monitors and establishes new cut-points to enable use of the 3-dimensional vector magnitude data (for both hip and wrist placement).

Methods

A total of 125 children ages 7–13 yrs performed 12 randomly selected activities (from a set of 24 different activities) for 5 min each while wearing tri-axial Actigraph accelerometers on both the hip and wrist. The accelerometer data were categorized as either sedentary or non-sedentary minutes using six previously studied cut-points: 100counts-per-minute (CPM), 200CPM, 300CPM, 500CPM, 800CPM and 1100CPM. Classification accuracy was evaluated with Cohen''s Kappa (κ) and new cut-points were identified from Receiver Operating Characteristic (ROC).

Results

Of the six cut-points, the 100CPM value yielded the highest classification accuracy (κ = 0.81) for hip placement. For wrist placement, all of the cut-points produced low classification accuracy (ranges of κ from 0.44 to 0.67). Optimal sedentary cut-points derived from ROC were 554.3CPM (ROC-AUC of 0.99) for vector magnitude for hip, 1756CPM (ROC-AUC of 0.94) for vertical axis for wrist, and 3958.3CPM (ROC-AUC of 0.93) for vector magnitude for wrist placement.

Conclusions

The 100CPM was supported for use with vertical axis for hip placement, but not for wrist placement. The ROC-derived cut-points can be used to classify youth SB with the wrist and with vector magnitude data.  相似文献   

2.

Background

Few studies have compared the validity of objective measures of physical activity energy expenditure (PAEE) in pregnant and non-pregnant women. PAEE is commonly estimated with accelerometers attached to the hip or waist, but little is known about the validity and participant acceptability of wrist attachment. The objectives of the current study were to assess the validity of a simple summary measure derived from a wrist-worn accelerometer (GENEA, Unilever Discover, UK) to estimate PAEE in pregnant and non-pregnant women, and to evaluate participant acceptability.

Methods

Non-pregnant (N = 73) and pregnant (N = 35) Swedish women (aged 20–35 yrs) wore the accelerometer on their wrist for 10 days during which total energy expenditure (TEE) was assessed using doubly-labelled water. PAEE was calculated as 0.9×TEE-REE. British participants (N = 99; aged 22–65 yrs) wore accelerometers on their non-dominant wrist and hip for seven days and were asked to score the acceptability of monitor placement (scored 1 [least] through 10 [most] acceptable).

Results

There was no significant correlation between body weight and PAEE. In non-pregnant women, acceleration explained 24% of the variation in PAEE, which decreased to 19% in leave-one-out cross-validation. In pregnant women, acceleration explained 11% of the variation in PAEE, which was not significant in leave-one-out cross-validation. Median (IQR) acceptability of wrist and hip placement was 9(8–10) and 9(7–10), respectively; there was a within-individual difference of 0.47 (p<.001).

Conclusions

A simple summary measure derived from a wrist-worn tri-axial accelerometer adds significantly to the prediction of energy expenditure in non-pregnant women and is scored acceptable by participants.  相似文献   

3.

Background

Accelerometers, initially waist-worn but increasingly wrist-worn, are used to assess physical activity free from reporting-bias. However, its acceptability by study participants is unclear. Our objective is to assess factors associated with non-consent to a wrist-mounted accelerometer in older adults.

Methods

Data are from 4880 Whitehall II study participants (1328 women, age range = 60–83), requested to wear a wrist-worn accelerometer 24 h every day for 9 days in 2012/13. Sociodemographic, behavioral, and health-related factors were assessed by questionnaire and weight, height, blood pressure, cognitive and motor function were measured during a clinical examination.

Results

210 participants had contraindications and 388 (8.3%) of the remaining 4670 participants did not consent. Women, participants reporting less physical activity and less favorable general health were more likely not to consent. Among the clinical measures, cognitive impairment (Odds Ratio = 2.21, 95% confidence interval: 1.22–4.00) and slow walking speed (Odds Ratio = 1.38, 95% confidence interval: 1.02–1.86) were associated with higher odds of non-consent.

Conclusions

The rate of non-consent in our study of older adults was low. However, key markers of poor health at older ages were associated with non-consent, suggesting some selection bias in the accelerometer data.  相似文献   

4.

Objective

To define accelerometer cut points for different walking speeds in older adults with mild to moderate Parkinson’s disease.

Method

A volunteer sample of 30 older adults (mean age 73; SD 5.4 years) with mild to moderate Parkinson’s disease walked at self-defined brisk, normal, and slow speeds for three minutes in a circular indoor hallway, each wearing an accelerometer around the waist. Walking speed was calculated and used as a reference measure. Through ROC analysis, accelerometer cut points for different levels of walking speed in counts per 15 seconds were generated, and a leave-one-out cross-validation was performed followed by a quadratic weighted Cohen’s Kappa, to test the level of agreement between true and cut point–predicted walking speeds.

Results

Optimal cut points for walking speeds ≤ 1.0 m/s were ≤ 328 and ≤ 470 counts/15 sec; for speeds > 1.3 m/s, they were ≥ 730 and ≥ 851 counts/15 sec for the vertical axis and vector magnitude, respectively. Sensitivity and specificity were 61%–100% for the developed cut points. The quadratic weighted Kappa showed substantial agreement: κ = 0.79 (95% CI 0.70–0.89) and κ = 0.69 (95% CI 0.56–0.82) for the vertical axis and the vector magnitude, respectively.

Conclusions

This study provides accelerometer cut points based on walking speed for physical-activity measurement in older adults with Parkinson’s disease for evaluation of interventions and for investigating links between physical activity and health.  相似文献   

5.
Use of illicit stimulants such as methamphetamine, cocaine, and ecstasy is a significant health problem. The United Nations Office on Drugs and Crime estimates that 14–57 million people use stimulants each year. Chronic use of illicit stimulants can cause neurotoxicity in animals and humans but the long-term functional consequences are not well understood. Stimulant users self-report problems with tremor whilst abstinent. Thus, the aim of the current study was to investigate the long-term effect of stimulant use on human tremor during rest and movement. We hypothesized that individuals with a history of stimulant use would exhibit abnormally large tremor during rest and movement. Tremor was assessed in abstinent ecstasy users (n = 9; 22±3 yrs) and abstinent users of amphetamine-like drugs (n = 7; 33±9 yrs) and in two control groups: non-drug users (n = 23; 27±8 yrs) and cannabis users (n = 12; 24±7 yrs). Tremor was measured with an accelerometer attached to the index finger at rest (30 s) and during flexion and extension of the index finger (30 s). Acceleration traces were analyzed with fast-Fourier transform. During movement, tremor amplitude was significantly greater in ecstasy users than in non-drug users (frequency range 3.9–13.3 Hz; P<0.05), but was unaffected in cannabis users or users of amphetamine-like drugs. The peak frequency of tremor did not significantly differ between groups nor did resting tremor. In conclusion, abstinent ecstasy users exhibit an abnormally large tremor during movement. Further work is required to determine if the abnormality translates to increased risk of movement disorders in this population.  相似文献   

6.

Background

The total activity volume performed is an overall measure that takes into account the frequency, intensity, and duration of activities performed. The importance of considering total activity volume is shown by recent studies indicating that light physical activity (LPA) and intermittent moderate-to-vigorous physical activity (MVPA) have health benefits. Accelerometer-derived total activity counts (TAC) per day from a waist-worn accelerometer can serve as a proxy for an individual''s total activity volume. The purpose of this study was to develop age- and gender-specific percentiles for daily TAC, minutes of MVPA, and minutes of LPA in U.S. youth ages 6 – 19 y.

Methods

Data from the 2003 – 2006 NHANES waist-worn accelerometer component were used in this analysis. The sample was composed of youth aged 6 – 19 years with at least 4 d of ≥ 10 hours of accelerometer wear time (N = 3698). MVPA was defined using age specific cutpoints as the total number of minutes at ≥4 metabolic equivalents (METs) for youth 6 – 17 y or minutes with ≥2020 counts for youth 18 – 19 y. LPA was defined as the total number of minutes between 100 counts and the MVPA threshold. TAC/d, MVPA, and LPA were averaged across all valid days.

Results

For males in the 50th percentile, the median activity level was 441,431 TAC/d, with 53 min/d of MVPA and 368 min/d of LPA. The median level of activity for females was 234,322 TAC/d, with 32 min/d of MVPA and 355 min/d of LPA.

Conclusion

Population referenced TAC/d percentiles for U.S. youth ages 6-19 y provide a novel means of characterizing the total activity volume performed by children and adolescents.  相似文献   

7.

Background

Physical inactivity is responsible for 5.3 million deaths annually worldwide. To measure physical activity energy expenditure, the doubly labeled water (DLW) method is the gold standard. However, questionnaires and accelerometry are more widely used. We compared physical activity measured by accelerometer and questionnaire against total (TEE) and physical activity energy expenditure (PAEE) estimated by DLW.

Methods

TEE, PAEE (TEE minus resting energy expenditure) and body composition were measured using the DLW technique in 25 adolescents (16 girls) aged 13 years living in Pelotas, Brazil. Physical activity was assessed using the Actigraph accelerometer and by self-report. Physical activity data from accelerometry and self-report were tested against energy expenditure data derived from the DLW method. Further, tests were done to assess the ability of moderate-to-vigorous intensity physical activity (MVPA) to predict variability in TEE and to what extent adjustment for fat and fat-free mass predicted the variability in TEE.

Results

TEE varied from 1,265 to 4,143 kcal/day. It was positively correlated with physical activity (counts) estimated by accelerometry (rho  = 0.57; p = 0.003) and with minutes per week of physical activity by questionnaire (rho  = 0.41; p = 0.04). An increase of 10 minutes per day in moderate-to-vigorous intensity physical activity (MVPA) relates to an increase in TEE of 141 kcal/day. PAEE was positively correlated with accelerometry (rho  = 0.64; p = 0.007), but not with minutes per week of physical activity estimated by questionnaire (rho  = 0.30; p = 0.15). Physical activity by accelerometry explained 31% of the vssariability in TEE. By incorporating fat and fat-free mass in the model, we were able to explain 58% of the variability in TEE.

Conclusion

Objectively measured physical activity significantly contributes to the explained variance in both TEE and PAEE in Brazilian youth. Independently, body composition also explains variance in TEE, and should ideally be taken into account when using accelerometry to predict energy expenditure values.  相似文献   

8.
Intra-procedural imaging is important for guiding cardiac arrhythmia ablation. It is difficult to obtain intra-procedural correlation of thermal lesion formation with action potential (AP) changes in the transmural plane during ablation. This study tested parametric ultrasound imaging for transmural imaging of lesion and AP changes in high intensity focused ultrasound (HIFU) ablation using coronary perfused canine ventricular wedge preparations (n = 13). The preparations were paced from epi/endocardial surfaces and subjected to HIFU application (3.5 MHz, 11 Hz pulse-repetition-frequency, 70% duty cycle, duration 4 s, 3500 W/cm2), during which simultaneous optical mapping (1 kframes/s) using di-4-ANEPPS and ultrasound imaging (30 MHz) of the same transmural surface of the wedge were performed. Spatiotemporally correlated AP measurements and ultrasound imaging allowed quantification of the reduction of AP amplitude (APA), shortening of AP duration at 50% repolarization, AP triangulation, decrease of optical AP rise, and change of conduction velocity along tissue depth direction within and surrounding HIFU lesions. The threshold of irreversible change in APA correlating to lesions was determined to be 43±1% with a receiver operating characteristic (ROC) area under curve (AUC) of 0.96±0.01 (n = 13). Ultrasound imaging parameters such as integrated backscatter, Rayleigh (α) and log-normal (σ) parameters, cumulative extrema of σ were tested, with the cumulative extrema of σ performing the best in detecting lesion (ROC AUC 0.89±0.01, n = 13) and change of APA (ROC AUC 0.79±0.03, n = 13). In conclusion, characteristic tissue and AP changes in HIFU ablation were identified and spatiotemporally correlated using optical mapping and ultrasound imaging. Parametric ultrasound imaging using cumulative extrema of σ can detect HIFU lesion and APA reduction.  相似文献   

9.

Background

Respiratory muscle contractile performance is impaired by diabetes, mechanisms of which included altered carbohydrate and lipid metabolism, oxidative stress and changes in membrane electrophysiology. The present study examined to what extent these cellular perturbations involve changes in gene expression.

Methodology/Principal Findings

Diaphragm muscle from streptozotocin-diabetic rats was analyzed with Affymetrix gene expression arrays. Diaphragm from diabetic rats had 105 genes with at least ±2-fold significantly changed expression (55 increased, 50 decreased), and these were assigned to gene ontology groups based on over-representation analysis using DAVID software. There was increased expression of genes involved in palmitoyl-CoA hydrolase activity (a component of lipid metabolism) (P = 0.037, n = 2 genes, fold change 4.2 to 27.5) and reduced expression of genes related to carbohydrate metabolism (P = 0.000061, n = 8 genes, fold change −2.0 to −8.5). Other gene ontology groups among upregulated genes were protein ubiquitination (P = 0.0053, n = 4, fold change 2.2 to 3.4), oxidoreductase activity (P = 0.024, n = 8, fold change 2.1 to 6.0), and morphogenesis (P = 0.012, n = 10, fold change 2.1 to 4.3). Other downregulated gene groups were extracellular region (including extracellular matrix and collagen) (P = 0.00032, n = 13, fold change −2.2 to −3.7) and organogenesis (P = 0.032, n = 7, fold change −2.1 to −3.7). Real-time PCR confirmed the directionality of changes in gene expression for 30 of 31 genes tested.

Conclusions/Significance

These data indicate that in diaphragm muscle type 1 diabetes increases expression of genes involved in lipid energetics, oxidative stress and protein ubiquitination, decreases expression of genes involved in carbohydrate metabolism, and has little effect on expression of ion channel genes. Reciprocal changes in expression of genes involved in carbohydrate and lipid metabolism may change the availability of energetic substrates and thereby directly modulate fatigue resistance, an important issue for a muscle like the diaphragm which needs to contract without rest for the entire lifetime of the organism.  相似文献   

10.

Objective

To evaluate the diagnostic value of acoustic radiation force impulse (ARFI) to test the elasticity of renal parenchyma by measuring the shear wave velocity (SWV) which might be used to detect chronic kidney disease (CKD).

Methods

327 healthy volunteers and 64 CKD patients were enrolled in the study. The potential influencing factors and measurement reproducibility were evaluated in the healthy volunteers. Correlations between SWV and laboratory tests were analyzed in CKD patients.?Receiver-operating characteristic curve (ROC) analyses were performed to assess the diagnostic performance of ARFI.

Results

The SWV of healthy volunteers correlated significantly to age (r = −0.22, P<0.001, n = 327) and differed significantly between men and women (2.06±0.48 m/s vs. 2.2±0.52 m/s, P = 0.018, n = 327). However, it did not correlate significantly to height, weight, body mass index, waistline, kidney dimension and the depth for SWV measurement (n = 30). Inter- and intraobserver agreement expressed as intraclass coefficient correlation were 0.64 (95% CI: 0.13 to 0.82, P = 0.011) and 0.6 (95% CI: 0.31 to 0.81, P = 0.001) (n = 40). The mean SWV in healthy volunteers was 2.15±0.51 m/s, while was 1.81±0.43 m/s, 1.79±0.29 m/s, 1.81±0.44 m/s, 1.64±0.55 m/s, and 1.36±0.17 m/s for stage 1, 2, 3, 4 and 5 in CKD patients respectively. The SWV was significantly higher for healthy volunteers compared with each stage in CKD patients. ARFI could not predict the different stages of CKD except stage 5. In CKD patients, SWV correlated to e-GFR (r = 0.3, P = 0.018), to urea nitrogen (r =  −0.3, P = 0.016), and to creatinine (r =  −0.41, P = 0.001). ROC analyses indicated that the area under the ROC curve was 0.752 (95% CI: 0.704 to 0.797) (P<0.001). The cut-off value for predicting CKD was 1.88 m/s (sensitivity 71.87% and specificity 69.69%).

Conclusion

ARFI may be a potentially useful tool in detecting CKD.  相似文献   

11.

Aim

The differentiation of destruction-induced thyrotoxicosis and Graves’ disease (GD) is of great importance for selection of proper therapy. Radioactive iodine uptake (RAIU) is the gold standard for differentiating these two conditions but its application has remained somewhat limited. Thyroid color Doppler flow sonography (CDFS) is a potential alternative of RAIU but more supporting evidence is warranted. In the present study, a standard operative procedure was developed to measure the mean peak systolic velocity of superior thyroid artery (STA-PSV) and evaluate its role in the differential diagnosis of thyrotoxicosis.

Methods

A total of 135 patients with untreated thyrotoxicosis were enrolled into one retrospective study (GD, n = 103; thyroiditis, n = 32) and another prospective study recruited 169 patients (GD, n = 118; thyroiditis, n = 51). Thirty normal controls were also enrolled. Thyroid function, anti-TSH-receptor antibody (TRAb), RAIU, CFDS of thyroid and STA-PSV were performed for each patient. Receiver operator curve (ROC) was used to evaluate the diagnostic value of STA-PSV in a retrospective study so as to seek the optimal cutoff point. Then the cutoff point value was used to validate its diagnostic value in a prospective study and in another thyrotoxicosis population.

Results

STA-PSV of GD was significantly higher than that of thyroiditis in both retrospective and prospective studies. The area under the ROC curve of mean STA-PSV was 0.8799 and 0.9447 in the retrospective and prospective studies respectively. If a mean STA-PSV cutoff point of 50.5 cm/s was set from the retrospective analysis for the prospective study, the sensitivity and specificity in distinguishing GD from thyroiditis were 81.04% and 96.08% respectively. Mean STA-PSV and TRAb had similar area under ROC. The coefficients of variation in STA-PSV measurement were lower than 10% for the euthyroid, thyroiditis and GD groups.

Conclusions

STA-PSV is a feasible supplement alternative of RAIU for differentiating the causes of thyrotoxicosis.  相似文献   

12.
A tumor can be viewed as a special “organ” that undergoes aberrant and poorly regulated organogenesis. Progress in cancer prognosis and therapy might be facilitated by re-examining distinctive processes that operate during normal development, to elucidate the intrinsic features of cancer that are significantly obscured by its heterogeneity. The global gene expression signatures of 44 human lung tissues at four development stages from Asian descent and 69 lung adenocarcinoma (ADC) tissue samples from ethnic Chinese patients were profiled using microarrays. All of the genes were classified into 27 distinct groups based on their expression patterns (named as PTN1 to PTN27) during the developmental process. In lung ADC, genes whose expression levels decreased steadily during lung development (genes in PTN1) generally had their expression reactivated, while those with uniformly increasing expression levels (genes in PTN27) had their expression suppressed. The genes in PTN1 contain many n-gene signatures that are of prognostic value for lung ADC. The prognostic relevance of a 12-gene demonstrator for patient survival was characterized in five cohorts of healthy and ADC patients [ADC_CICAMS (n = 69, p = 0.007), ADC_PNAS (n = 125, p = 0.0063), ADC_GSE13213 (n = 117, p = 0.0027), ADC_GSE8894 (n = 62, p = 0.01), and ADC_NCI (n = 282, p = 0.045)] and in four groups of stage I patients [ADC_CICAMS (n = 22, p = 0.017), ADC_PNAS (n = 76, p = 0.018), ADC_GSE13213 (n = 79, p = 0.02), and ADC_qPCR (n = 62, p = 0.006)]. In conclusion, by comparison of gene expression profiles during human lung developmental process and lung ADC progression, we revealed that the genes with a uniformly decreasing expression pattern during lung development are of enormous prognostic value for lung ADC.  相似文献   

13.

Background

It is unknown whether using different published thresholds (PTs) for classifying physical activity (PA) impacts upon activity-health relationships. This study explored whether relationships between PA (sedentary [SED], light PA [LPA], moderate PA [MPA], moderate-to-vigorous PA, vigorous PA [VPA]) and health markers differed in children when classified using three different PTs.

Methods

104 children (63 girls) aged 10–14 years wore an RT3 triaxial accelerometer for seven days and measures of adiposity and cardiometabolic risk markers were taken.

Results

Significant associations (p< .05) in boys were found between LPA and body mass index z-score and waist circumference z-score for the Rowlands et al PT only (β =  .459 and.401, respectively) and body fat% (BF%) for the Chu et al PT only (β = .322) and in girls with BF% for the Rowlands et al PT only (β =  .303) and systolic BP and blood glucose for the Vanhelst et al PT only (β = −.298 and −.283, respectively). MPA was significantly (p<.05) associated with BF%, diastolic BP, and cardiorespiratory fitness (CRF) for the Chu et al PT only in girls (β = −.436, −.529, and .446, respectively). SED was significantly (p<.05) associated with triglycerides (β = .492) for the Rowlands et al PT only in boys and VPA with CRF (p<.05) for the Rowlands et al and Vanhelst et al PTs only in girls (β = .416 and .352, respectively).

Conclusions

The choice of PT impacted upon activity-health relationships. A consensus on appropriate accelerometer thresholds for quantifying PA intensity and sedentary behaviour is needed in order to make accurate evidence-based recommendations for health promotion.  相似文献   

14.

Purpose

Vemurafenib is a potent inhibitor of V600 mutant BRAF with significant impact on progression-free and overall survival in advanced melanoma. Cutaneous side effects are frequent. This single-center observational study investigates clinical and histological features of these class-specific cutaneous adverse reactions.

Patients and Methods

Patients were all treated with Vemurafenib 960 mg b.i.d. within local ethic committees approved clinical trials. All skin reactions were collected and documented prospectively. Cutaneous reactions were classified by reaction pattern as phototoxic and inflammatory, hair and nail changes, keratinocytic proliferations and melanocytic disorders.

Results

Vemurafenib was well tolerated, only in two patients the dose had to be reduced to 720 mg due to arthralgia. 26/28 patients (93%) experienced cutaneous side effects. Observed side effects included UVA dependent photosensitivity (n = 16), maculopapular exanthema (n = 14), pruritus (n = 8), folliculitis (n = 5), burning feet (n = 3), hair thinning (mild alopecia) (n = 8), curly hair (n = 2) and nail changes (n = 2). Keratosis pilaris and acanthopapilloma were common skin reactions (n = 12/n = 13), as well as plantar hyperkeratosis (n = 4), keratoacanthoma (n = 5) and invasive squamous cell carcinoma (n = 4). One patient developed a second primary melanoma after more than 4 months of therapy (BRAF and RAS wild type).

Conclusion

Vemurafenib has a broad and peculiar cutaneous side effect profile involving epidermis and adnexa overlapping with the cutaneous manifestations of genetic diseases characterized by activating germ line mutations of RAS (RASopathy). They must be distinguished from allergic drug reaction. Regular skin examination and management by experienced dermatologists as well as continuous prophylactic photo protection including an UVA optimized sun screen is mandatory.  相似文献   

15.

Context

Cost-effective, scalable programs are urgently needed in countries deeply affected by HIV.

Methods

This parallel-group RCT was conducted in four secondary schools in Mbarara, Uganda. Participants were 12 years and older, reported past-year computer or Internet use, and provided informed caregiver permission and youth assent. The intervention, CyberSenga, was a five-hour online healthy sexuality program. Half of the intervention group was further randomized to receive a booster at four-months post-intervention. The control arm received ‘treatment as usual’ (i.e., school-delivered sexuality programming). The main outcome measures were: 1) condom use and 2) abstinence in the past three months at six-months'' post-intervention. Secondary outcomes were: 1) condom use and 2) abstinence at three-month''s post-intervention; and 6-month outcomes by booster exposure. Analyses were intention to treat.

Results

All 416 eligible youth were invited to participate, 88% (n = 366) of whom enrolled. Participants were randomized to the intervention (n = 183) or control (n = 183) arm; 91 intervention participants were further randomized to the booster. No statistically significant results were noted among the main outcomes. Among the secondary outcomes: At three-month follow-up, trends suggested that intervention participants (81%) were more likely to be abstinent than control participants (74%; p = 0.08), and this was particularly true among youth who were abstinent at baseline (88% vs. 77%; p = 0.02). At six-month follow-up, those in the booster group (80%) reported higher rates of abstinence than youth in the intervention, no booster (57%) and control (55%) groups (p = 0.15); they also reported lower rates of unprotected sex (5%) compared to youth in the intervention, no booster (24%) and control (21%) groups (p = 0.21) among youth sexually active at baseline.

Conclusions

The CyberSenga program may affect HIV preventive behavior among abstinent youth in the short term and, with the booster, may also promote HIV preventive behavior among sexually active youth in the longer term.

Trial Registration

NCT00906178.  相似文献   

16.

Background

Endocannabinoids and temperament traits have been linked to both physical activity and body mass index (BMI) however no study has explored how these factors interact in females. The aims of this cross-sectional study were to 1) examine differences among distinct BMI groups on daytime physical activity and time spent in moderate-vigorous physical activity (MVPA), temperament traits and plasma endocannabinoid concentrations; and 2) explore the association and interaction between MVPA, temperament, endocannabinoids and BMI.

Methods

Physical activity was measured with the wrist-worn accelerometer Actiwatch AW7, in a sample of 189 female participants (43 morbid obese, 30 obese, and 116 healthy-weight controls). The Temperament and Character Inventory-Revised questionnaire was used to assess personality traits. BMI was calculated by bioelectrical impedance analysis via the TANITA digital scale. Blood analyses were conducted to measure levels of endocannabinoids and endocannabinoid-related compounds. Path-analysis was performed to examine the association between predictive variables and MVPA.

Results

Obese groups showed lower MVPA and dysfunctional temperament traits compared to healthy-weight controls. Plasma concentrations of 2-arachidonoylglyceryl (2-AG) were greater in obese groups. Path-analysis identified a direct effect between greater MVPA and low BMI (b = −0.13, p = .039) and high MVPA levels were associated with elevated anandamide (AEA) levels (b = 0.16, p = .049) and N-oleylethanolamide (OEA) levels (b = 0.22, p = .004), as well as high Novelty seeking (b = 0.18, p<.001) and low Harm avoidance (b = −0.16, p<.001).

Conclusions

Obese individuals showed a distinct temperament profile and circulating endocannabinoids compared to controls. Temperament and endocannabinoids may act as moderators of the low MVPA in obesity.  相似文献   

17.
Ectopic pregnancy (EP) is difficult to diagnose early and accurately. Women often present at emergency departments in early pregnancy with a ‘pregnancy of unknown location’ (PUL), and diagnosis and exclusion of EP is challenging due to a lack of reliable biomarkers. The objective of this study was to identify novel diagnostic biomarkers for EP. Shotgun proteomics, incorporating combinatorial-ligand library pre-fractionation, was used to interrogate pooled sera (n = 40) from women undergoing surgery for EP, termination of viable intrauterine pregnancy and management of non-viable intrauterine pregnancy. Western blot was used to validate results in individual sera. ELISAs were developed to interrogate sera from women with PUL (n = 120). Sera were collected at time of first symptomatic presentation and categorized according to pregnancy outcome. The main outcome measures were differences between groups and area under the receiver operating curve (ROC). Proteomics identified six biomarker candidates. Western blot detected significant differences in levels of two of these candidates. ELISA of sera from second cohort revealed that these differences were only significant for one of these candidates, fibronectin. ROC analysis of ability of fibronectin to discriminate EP from other pregnancy outcomes suggested that fibronectin has diagnostic potential (ROC 0.6439; 95% CI 0.5090 to 0.7788; P>0.05), becoming significant when ‘ambiguous’ medically managed PUL excluded from analysis (ROC 0.6538; 95% CI 0.5158 to 0.7918; P<0.05). Fibronectin may make a useful adjunct to future multiplex EP diagnostic tests.  相似文献   

18.
Recently, it was demonstrated that a uniaxial accelerometer worn at the hip could estimate resistance exercise energy expenditure. As resistance exercise takes place in more than 1 plane, the use of a triaxial accelerometer may be more effective in estimating resistance exercise energy expenditure. The aims of this study were to estimate the energy cost of resistance exercise using triaxial accelerometry and to determine the optimal location for wearing triaxial accelerometers during resistance exercise. Thirty subjects (15 men and 15 women; age = 21.7 ± 1.0 years) performed a resistance exercise protocol consisting of 2 sets of 8 exercises (10RM loads). During the resistance exercise protocol, subjects wore triaxial accelerometers on the wrist, waist, and ankle; a heart rate monitor; and a portable metabolic system. Net energy expenditure was significantly correlated with vertical (r = 0.67, p < 0.001), horizontal (r = 0.43, p = 0.02), third axis (r = 0.36, p = 0.048), and sum of 3 axes (r = 0.50, p = 0.005) counts at the waist, and horizontal counts at the wrist (r = -0.40, p = 0.03). Regression analysis using fat-free mass, sex, and the sum of accelerometer counts at the waist as variables was used to develop an equation that explained 73% of the variance of resistance exercise energy expenditure. A triaxial accelerometer worn at the waist can be used to estimate resistance exercise energy expenditure but appears to offer no benefit over uniaxial accelerometry. The use of accelerometers in estimating resistance exercise energy expenditure may prove useful for individuals and athletes who participate in resistance training and are focused on maintaining a tightly regulated energy balance.  相似文献   

19.
Older adults typically experience greater levels of thermal strain during physical efforts in the heat compared to young individuals. While this may be related to an age-dependent reduction in whole-body sweating, no study has clearly delineated at what age this occurs. In the present study, we report direct measurements of human heat dissipation during physical activity in the heat in males ranging in age from 20–70 years. Eighty-five males performed four 15-min bouts of cycling separated by 15-min rest periods, in a calorimeter regulated to 35°C and 20% relative humidity. Direct calorimetry was used to measure total heat loss (whole-body evaporative heat loss and dry heat exchange). We also used indirect calorimetry as a continuous measure of metabolic heat production. Body heat storage was calculated as the temporal summation of heat production and total heat loss over the experimental session. Whole-body sweat rate (WBSR) was calculated from measurements of evaporative heat loss. Males were divided into five age categories for the analysis of WBSR and body heat storage: 20–31 years (n = 18), 40–44 years (n = 15), 45–49 years (n = 15), 50–55 years (n = 21) and 56–70 years (n = 16). Relative to young males, WBSR was reduced in males aged 56–70 during each exercise (all P<0.05), in males aged 50–55 during the second (P = 0.031) and third exercises (P = 0.028) and in males aged 45–49 during the final exercise bout (P = 0.046). Although not significantly different, 40–44 years old males also had a lower rate of heat loss compared to younger males. Over the sum of two hours, the change in body heat content was greater in males 40–70 years compared to young males (all P<0.05). Our findings suggest that middle-aged and older adults have impairments in heat dissipation when doing physical activity in the heat, thus possibly increasing their risk of heat-related illness under such conditions.  相似文献   

20.

Background

When using accelerometers to measure physical activity, researchers need to determine whether subjects have worn their device for a sufficient period to be included in analyses. We propose a minimum wear criterion using population-based accelerometer data, and explore the influence of gender and the purposeful inclusion of children with weekend data on reliability.

Methods

Accelerometer data obtained during the age seven sweep of the UK Millennium Cohort Study were analysed. Children were asked to wear an ActiGraph GT1M accelerometer for seven days. Reliability coefficients(r) of mean daily counts/minute were calculated using the Spearman-Brown formula based on the intraclass correlation coefficient. An r of 1.0 indicates that all the variation is between- rather than within-children and that measurement is 100% reliable. An r of 0.8 is often regarded as acceptable reliability. Analyses were repeated on data from children who met different minimum daily wear times (one to 10 hours) and wear days (one to seven days). Analyses were conducted for all children, separately for boys and girls, and separately for children with and without weekend data.

Results

At least one hour of wear time data was obtained from 7,704 singletons. Reliability increased as the minimum number of days and the daily wear time increased. A high reliability (r = 0.86) and sample size (n = 6,528) was achieved when children with ≥ two days lasting ≥10 hours/day were included in analyses. Reliability coefficients were similar for both genders. Purposeful sampling of children with weekend data resulted in comparable reliabilities to those calculated independent of weekend wear.

Conclusion

Quality control procedures should be undertaken before analysing accelerometer data in large-scale studies. Using data from children with ≥ two days lasting ≥10 hours/day should provide reliable estimates of physical activity. It’s unnecessary to include only children with accelerometer data collected during weekends in analyses.  相似文献   