首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
A technique of phase-polarisation contrast (PPC) for the enhancement of the contrast of a surface plasmon resonance (SPR) intensity profile is proposed and experimentally realised. The technique exploits the peculiarities of light phase and polarisation behaviour under SPR. It applies to non-optimum SPR coupling conditions and enables one to lower the resonant minimum of reflected intensity nearly to zero, and hence to increase substantially the ratio of the intensity from the resonance to that at the minimum. We observed the contrast enhancement by more than one order of magnitude when we applied the PPC scheme. The PPC can be efficiently employed in commercial SPR sensors, as it significantly reduces restrictions on allowable parameters of SPR-supporting metal films and biomolecular layers immobilised on them, facilitates SPR observation, and increases the accuracy of SPR shift measurements.  相似文献   

2.
An optical biosensor employing surface plasmon resonance (SPR; SPR-biosensor) is a highly efficient instrument applicable for direct real time registration of molecular interactions without additional use of any labels or coupled processes. As an independent approach it is especially effective in analysis of various ligand receptor interactions. SPR-biosensors are used for validation of studies on intermolecular interactions in complex biological systems (affinity profiling of various groups of proteins, etc.). Recently, potential application of the SPR-biosensor for molecular fishing (direct affinity binding of target molecules from complex biological mixtures on the optical biosensor surface followed by their elution for identification by LCMS/MS) has been demonstrated. Using SPR-biosensors in such studies it is possible to solve the following tasks: (a) SPR-based selection of immobilization conditions required for the most effective affinity separation of a particular biological sample; (b) SPR-based molecular fishing for subsequent protein identification by mass spectrometry; (c) SPR-based validation of the interaction of identified proteins with immobilized ligand. This review considers practical application of the SPR technology in the context of recent studies performed in the Institute of Biomedical Chemistry on molecular fishing of real biological objects.  相似文献   

3.
Surface plasmon resonance (SPR) permits the quantitative analysis of therapeutic antibody concentrations and impurities including bacteria, Protein A, Protein G and small molecule ligands leached from chromatography media. The use of surface plasmon resonance has gained popularity within the biopharmaceutical industry due to the automated, label free, real time interaction that may be exploited when using this method. The application areas to assess protein interactions and develop analytical methods for biopharmaceutical downstream process development, quality control, and in-process monitoring are reviewed.  相似文献   

4.
A novel method for sensitivity enhancement of spectral surface plasmon resonance (SPR) biosensors was presented by reducing the refractive index of the sensing prism in the analysis of protein arrays. Sensitivity of spectral SPR biosensors with two different prisms (BK-7, fused silica) was analyzed by net shifts of resonance wavelength for specific interactions of GST–GTPase binding domain of p21-activated kinase-1 and anti-GST on a mixed thiol surface. Sensitivity was modulated by the refractive index of the sensing prism of the spectral SPR biosensors with the same incidence angle. The sensitivity of a spectral SPR biosensor with a fused silica prism was 1.6 times higher than that with a BK-7 prism at the same incidence angle of 46.2°. This result was interpreted by increment of the penetration depth correlated with evanescent field intensity at the metal/dielectric interface. Therefore, it is suggested that sensitivity enhancement is readily achieved by reducing the refractive index of the sensing prism of spectral SPR biosensors to be operated at long wavelength ranges for the analysis of protein arrays.  相似文献   

5.
Surface Plasmon Resonance (SPR) biosensor technology has been successfully used for the detection of various analytes such as proteins, drugs, DNA, and microorganisms. SPR-based immunosensors that coupled with a specific antigen-antibody reaction, have become a promising tool for the quantification of bacteria as it offers sensitive, specific, rapid, and label-free detection. In this paper, we review the important issues in the development of SPR-based immunoassays for bacteria detection, concentrating on instrumentation, surface functionalization, liquid handling, and surface regeneration. In addition, this review touches on the recent advances in SPR biosensing for sensitivity enhancement.  相似文献   

6.
SPR biosensing is increasingly popular for the detection of a multitude of biomolecules. It offers label-free detection and study of proteins, nucleic acids, and other biomolecules in real time. A recent trend involves incorporation of AuNPs, either within the sensing surface itself or as signal enhancing tagging molecules. The importance of AuNP and detecting agent spacing is described and techniques using macromolecular spacing aids are highlighted. Recent methods to enhance SPR detection capabilities using gold nanoparticles are reviewed, as well as device fabrication and the results of incorporation. SPR detection is a highly versatile method for the detection of biomolecules and, with the incorporation of AuNPs, shows promise in extending it to a number of new applications.  相似文献   

7.
8.
We have developed a new method for highly selective determination of the ubiquitin carboxyl-terminal hydrolase L1 (UCH-L1) concentration using a surface plasmon resonance imaging (SPRI) technique and two different biosensors. UCH-L1 was captured from a solution by immobilized specific rabbit monoclonal antibody or specific LDN-57444 inhibitor due to formation of receptor–UCH-L1 complex on the biosensor surface. The analytically useful dynamic response range of both biosensors is between 0.1 and 2.5 ng/ml. The detection limit is 0.06 ng/ml for the biosensor with antibody and 0.08 ng/ml for the biosensor with inhibitor. Biosensors based on both antibody and inhibitor were found to be suitable for quantitative determination of the UCH-L1 and exhibit good tolerance to the potential interferents. Both biosensors gave comparable results in the range of 0 to 0.20 ng/ml for plasma samples and 0.30 to 0.49 ng/ml for cerebrospinal fluid samples. To validate the new methods, comparative determination of UCH-L1 by the commercial enzyme-linked immunosorbent assay (ELISA) kit was performed. In general, in terms of UCH-L1 concentration, a good correlation between SPRI and ELISA was found. The developed biosensors can be used successfully for the determination of UCH-L1 in body fluids.  相似文献   

9.
10.
Current surface plasmon resonance (SPR) modes based on the attenuated total reflection (ATR) method can broadly be categorized as: conventional SPR, long-range SPR (LRSPR), coupled plasmon-waveguide resonance (CPWR), and waveguide-coupled SPR (WCSPR). Although the features of optical biosensors are dependent upon their particular SPR mode, a common requirement for all biosensors utilized for biomolecular interaction analysis (BIA) is a high degree of sensitivity. The current paper presents a theoretical analysis and comparison of the sensitivity and resolution of these four types of SPR biosensors when employed in three of the most prevalent detection methods, namely angular interrogation, wavelength interrogation, and intensity measurement. This study develops a detailed understanding of the influences of various biosensor design parameters in order to enhance the sensitivity and detection limit capabilities of such devices.  相似文献   

11.
Surface plasmon resonance (SPR)-based biosensing is one of the most advanced label free, real time detection technologies. Numerous research groups with divergent scientific backgrounds have investigated the application of SPR biosensors and studied the fundamental aspects of surface plasmon polaritons that led to new, related instrumentation. As a result, this field continues to be at the forefront of evolving sensing technology. This review emphasizes the new developments in the field of SPR-related instrumentation including optical platforms, chips design, nanoscale approach and new materials. The current tendencies in SPR-based biosensing are identified and the future direction of SPR biosensor technology is broadly discussed.  相似文献   

12.
This work presents a kinetic approach of the interaction between acetylcholinesterase (AChE) from electric eel and aflatoxin B1 (AFB1) or its protein conjugate (e.g., AFB1–HRP [horseradish peroxidase]) in order to develop a simple and sensitive detection method of these compounds. The dissociation constant Kd of the AChE/AFB1–HRP interaction (0.4 μM) obtained with the surface plasmon resonance (SPR) technique is very close to the inhibition constant reported in amperometric assay (Ki = 0.35 μM), proving that the conjugation of AFB1 to a carrier protein does not significantly influence the affinity of AFB1 for AChE. Thus, the AChE/AFB1–HRP couple can be used as mimic system for the binding of AChE to other AFB1–protein adducts and further used for developing biosensors for AFB1 bound to plasma proteins. The immobilization protocol was designed to minimize the nonspecific adsorption on the self-assembled monolayer (SAM) functionalized surface of the SPR chip without an additional hydrophilic linker, whereas the interaction protocol was designed to mark out the possible occurrence of mass transport limitation (MTL) effects. The detection limits (LODs) were 0.008 μM for AFB1–HRP (2.5 ng ml?1 AFB1) and 0.94 ng ml?1 for AFB1 itself, which is lower than recently reported values in spectrophotometric and amperometric assays.  相似文献   

13.
This paper presents a simple method to extract information about thin organic films from surface plasmon resonance (SPR) spectra. From numerical simulations it was found that a shift (Δθ SPR) of an absorption peak in the SPR spectrum was directly proportional to the product of the thin organic film thickness and the refractive index difference between the thin organic film and a buffer soaking the sample. It was also found that Δθ SPR was not sensitive to the thin organic film support of a gold film and a glass cover slip. Relationships between Δθ SPR and distributions of macromolecule structures, in the thin organic films were theoretically established. Formulae were derived for a homemade SPR system to calculate length, transverse area, density and surface concentration of macromolecules in the thin organic film. The validity of these treatments was checked by precisely measuring the size of a single distearoylphosphatidylcholine molecule on a gold-supported phospholipid film; by quantitatively monitoring hybridization of synthesized oligonucleotides strands based on a biotin/avidin system; and by quantitatively detecting the steric hindrance of rabbit C-reactive protein specifically bound to phospholipid monolayers composed of synthesized lipids. Received: 4 May 1998 / Revised version: 27 July 1998 / Accepted: 27 August 1998  相似文献   

14.
Substrate-supported planar lipid bilayers are generated most commonly by the adsorption and transformation of phospholipid vesicles (vesicle fusion). We have recently demonstrated that simultaneous measurements of surface plasmon resonance (SPR) and surface plasmon fluorescence spectroscopy (SPFS) are highly informative for monitoring lipid membranes on solid substrates. SPR and SPFS provide information on the amount and topography of adsorbed lipid membranes, respectively. In this study, the vesicle fusion process was studied in detail by measuring SPR-SPFS at a higher rate and plotting the obtained fluorescence intensity versus film thickness. We could track the initial adsorption of vesicles, the onset of vesicle rupture occurring at certain vesicle coverage of the surface, and the autocatalytic transformation into planar bilayers. We also monitored vesicle fusion of the same vesicle suspensions by quartz crystal microbalance with dissipation monitoring (QCM-D). We compared the results obtained from SPR-SPFS and QCM-D to highlight the unique information provided by SPR-SPFS.  相似文献   

15.
Surface plasmon resonance (SPR) biosensors are affinity sensing devices exploiting a special mode of electromagnetic field-surface plasmon-polariton-to detect the binding of analyte molecules from a liquid sample to biomolecular recognition elements immobilized on the surface of the sensor. In this paper, we review advances of SPR biosensor technology towards detection systems for the simultaneous detection of multiple analytes (multi-analyte detection). In addition, we report application of a recently developed multichannel SPR sensor based on spectroscopy of surface plasmons and wavelength division multiplexing of sensing channels to multi-analyte detection.  相似文献   

16.
In this study, we prepared metallic corrugated structures for use as highly sensitive plasmonic sensors. Relying on the direct nanoimprint-in-metal method, fabrication of this metallic corrugated structure was readily achieved in a single step. The metallic corrugated structures were capable of sensing both surface plasmon resonance (SPR) wavelengths and index-matching effects. The corrugated Au films exhibited high sensitivity (ca. 800 nm/RIU), comparable with or even higher than those of other reported SPR-based sensors. Because of the unique index-matching effect, refractometric sensing could also be performed by measuring the transmission intensity of the Au/substrate SPR mode-conveniently, without a spectrometer. In the last, we demonstrated the corrugated Au film was capable of sensing biomolecules, revealing the ability of the structure to be a highly sensitive biosensor.  相似文献   

17.
Substrate-supported planar lipid bilayer membranes are attractive model cellular membranes for biotechnological applications such as biochips and sensors. However, reliable fabrication of the lipid membranes on solid surfaces still poses significant technological challenges. In this study, simultaneous surface plasmon resonance (SPR) and surface plasmon fluorescence spectroscopy (SPFS) measurements were applied to the monitoring of adsorption and subsequent reorganization of phospholipid vesicles on solid substrates. The fluorescence intensity of SPFS depends very sensitively on the distance between the gold substrate and the fluorophore because of the excitation energy transfer to gold. By utilizing this distance dependency, we could obtain information about the topography of the adsorbed membranes: Adsorbed vesicles could be clearly distinguished from planar bilayers due to the high fluorescence intensity. SPSF can also incorporate various analytical techniques to evaluate the physicochemical properties of the adsorbed membranes. As an example, we demonstrated that the lateral mobility of lipid molecules could be estimated by observing the recovery of fluorescence after photobleaching. Combined with the film thickness information obtained by SPR, SPR-SPFS proved to be a highly informative technique to monitor the lipid membrane assembly processes on solid substrates.  相似文献   

18.
A suite of biosensors for rapid detection of inducible nitric oxide synthase (iNOS) is described. First, a metal-enhanced electrochemical detection (MED) sensor, which relied on the redox properties of a silver monolayer, was developed. The linear detection range was between 8.64 × 10−2 and 5.4 × 101 ng/ml with a detection limit of 1.69 × 10−4 ng/ml. This method was compared with surface plasmon resonance (SPR) biosensors in which polyclonal mouse anti-iNOS was covalently immobilized onto a gold surface using an iNOS antigen. The linear detection range recorded was between 3.37 × 101 and 5.4 × 10−2 ng/ml with a detection limit of 2 × 10−3 ng/ml. Finally, an ultrasensitive portable capillary (UPAC) fluorescence immunosensor, in which a mouse anti-iNOS antibody was covalently immobilized onto the inner surface of a capillary and a rabbit anti-iNOS antibody was employed as the secondary antibody, was developed. The resulting signals were found to be directly proportional to iNOS concentrations between 1.52 × 10−1 and 1.52 × 10−2 ng/ml with a detection limit of 1.05 × 10−3 ng/ml. These immunosensors exhibit low cross-reactivity toward potential interferents such as human serum albumin and ovalbumin. The SPR and UPAC biosensors were validated using simulated blood spiked with recombinant iNOS, resulting in recoveries of 85% and 88.5%, respectively. The research presented in this article could potentially provide new ways of detecting NO for diagnostic and biomarker purposes in medical research.  相似文献   

19.
Surface plasmon resonance (SPR)-based biosensors were investigated with a view to providing a portable, inexpensive alternative to existing technologies for "real-time" biomolecular interaction analysis of whole cell-ligand interactions. A fiber optic SPR-based (FOSPR) biosensor, employing wavelength-dependent SPR, was constructed to enable continuous real-time data acquisition. In addition, a commercially available integrated angle-dependent SPR-based refractometer (ISPR) was modified to facilitate biosensing applications. Solid-phase detection of whole red blood cells (RBCs) using affinity-captured blood group specific antibodies was demonstrated using the BIACORE 1000, BIACORE Probe, FOSPR, and ISPR sensors. Nonspecific binding of RBCs to the hydrogel-based biointerface was negligible. However, the background noise level of the FOSPR-based biosensor was approximately 25-fold higher than that of the widely used BIACORE 1000 system while that of the ISPR-based biosensor was over 100-fold higher. Nevertheless, the FOSPR biosensor was suitable for the analysis of macromolecular analytes contained in crude matrices.  相似文献   

20.
A surface plasmon resonance (SPR) assay without surface regeneration was developed for rapid and sensitive detection of chloramphenicol (CAP). A CAP-amine derivative was synthesized using a polyethylene glycol chain attached to the CAP through a carbamate linkage and immobilized onto a Biacore dextran surface. This chemically modified surface significantly changed the binding behavior between antibody and CAP, shown by both fast association and fast dissociation rates, and created a rapid and sensitive SPR immunoassay of the CAP without any regeneration. The limits of detection achieved for CAP were 32.2 pg/ml in aqueous buffer and 42.4 pg/ml in honey-spiked samples.  相似文献   