首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 10 毫秒
1.
2.
Separations of all major cyclooxygenase and lipoxygenase metabolites of arachidonic acid were obtained by high performance liquid chromatography (HPLC). A C18 reverse-phase column was used in ion suppression mode to separate underivatized metabolites of arachidonic acid isolated from human and rabbit platelets. The metabolites were monitored by measuring radioactivity or ultraviolet light absorption at 192 nm (absorption by double bonds). Comparisons of TLC and HPLC separations demonstrated that the HPLC separation of metabolites of [1-14C]arachidonic acid was quantitative. HPLC also resolved several minor metabolites that were not detected by scanning of TLC separations.  相似文献   

3.
High-performance liquid chromatography procedures were developed which separate leukotrienes (LTs), hydroxy-fatty acids (HETEs), prostaglandins (PGs), the stable metabolite of prostacyclin (6-keto-PGF1 alpha), the stable metabolite of thromboxane A2 (TXB2), 12-hydroxyheptadecatrienoic acid (HHT), and arachidonic acid (AA). Two methods employing reverse-phase columns are described. One method uses a radial compression system, the other a conventional steel column. Both systems employ methanol and buffered water as solvents. The radial compression system requires 60 min for separation of the AA metabolites, while the conventional system requires 100 min. Both methods provide good separation and recovery of 6-keto-PGF1 alpha, TXB2, PGE2, PGF2 alpha, PGD2, LTC4, LTB4, LTD4, LTE4, HHT, 15-, 12-, and 5-HETE; and AA. The 5S,12S-dihydroxy-6-trans, 8-cis, 10-trans, 14-cis-eicosatetraenoic acid (5S,12S-diHETE), a stereoisomer of LTB4, coelutes with LTB4. To determine the applicability of the methods to biologic systems, AA metabolism was studied in two models, guinea pig lung microsomes and rat alveolar macrophages. Both HPLC systems demonstrated good recovery and resolution of eicosanoids from the two biological systems. A simple evaporation technique for HPLC sample preparation, which avoids the use of chromatographic and other time-consuming methodology, is also described.  相似文献   

4.
We have utilized HPLC to develop optimal conditions for assaying the transformation of arachidonic acid in thrombin-treated human platelets. In the presence of increasing amounts of albumin, the total amount of radioactivity released from thrombin-treated platelets pre-labeled with 3H-arachidonic acid is first enhanced and then inhibited. Maximal release, reflecting primarily enhanced amounts of free labeled arachidonic acid, occurs at a final albumin concentration of 0.5 mg/ml. Calcium promoted the release of all radiolabeled metabolites, but it specifically enhanced HETE formation and release. Magnesium was without effect. Cyclo-oxygenase derived products constituted the bulk of released label at short time intervals, but after ten minutes exposure to thrombin in the presence of albumin (0.5 mg/ml) and 3 mM calcium, radioactivity in the released products was equally distributed among cyclo-oxygenase derived products (TXB2 + PGD2 + HHT), HETE and free arachidonic acid.  相似文献   

5.
We have utilized HPLC to develop optimal conditions for assaying the transformation of arachidonic acid in thrombin-treated human platelets. In the presence of increasing amounts of albumin, the total amount of radioactivity released from thrombin-treated platelets pre-labeled with 3H-arachidonic acid is first enhanced and then inhibited. Maximal release, reflecting primarily enhanced amounts of free labeled arachidonic acid, occurs at a final albumin concentration of 0.5 mg/ml. Calcium promoted the release of all radiolabeled metabolites, but it specifically enhanced HETE formation and release. Magnesium was without effect. Cyclo-oxygenase derived products constituted the bulk of released label at short time intervals, but after ten minutes exposure to thrombin in the presence of albumin (0.5 mg/ml) and 3 mM calcium, radioactivity in the released products was equally distributed among cyclo-oxygenase derived products (TXB2 + PGD2 + HHT), HETE and free arachidonic acid.  相似文献   

6.
High-pressure liquid chromatography is required to resolve the complex mixtures of arachidonic acid metabolites synthesized by many tissues. We have investigated some of the factors which affect the retention times of these substances in reversed-phase HPLC on columns of 5-micron octadecylsilyl silica. There are considerable differences in selectivity between mobile phases based on methanol and those based on acetonitrile, the latter being much better for cyclooxygenase products. The chromatographic behavior of peptidoleukotrienes (LTC4, LTD4, and LTE4) is quite different from that of other arachidonic acid metabolites which do not contain amino acids. Addition of phosphoric acid to the mobile phase results in very long retention times for peptidoleukotrienes. Very low concentrations of trifluoroacetic acid have effects similar to that of phosphoric acid, but as its concentration is raised, the retention times of peptidoleukotrienes decrease, whereas those of other arachidonic acid metabolites are unaffected. Changing the concentration of acetonitrile in the mobile phase also affects the retention times of peptidoleukotrienes differently from those of other metabolites. This information has been used to devise simple linear gradients which separate most of the major cyclooxygenase and lipoxygenase products of arachidonic acid metabolism.  相似文献   

7.
Recent increases in the ability to detect low levels of immunofluorescence have shown the need for highly purified primary immunoreagents. There are now reports of purification of monoclonal antibodies using HPLC with reverse phase columns. In this study we have utilized standard size exclusion HPLC to purify both biotinylated and non-biotinylated monoclonal antibodies from hybridoma culture supernatants. Results indicated that both biotinylated and non-biotinylated monoclonal antibodies retained their antigen binding capacity after purification, and were not different in this capacity from commercially available, affinity purified reagents. These findings indicate that size exclusion HPLC may be used in the purification of biologically active monoclonal antibodies, and suggest that this technique may be used in the large scale production of antibodies and their fragments, in antibody purification from ascites fluid, and in antisera quality control.  相似文献   

8.
We have developed a technique for the rapid separation and quantitative collection of thromboxane B2 (TXB2), PGE2, PGD2, PGF2 alpha, 12-hydroxy-5,8,10 heptadecatrienoic acid (HHT), 12-L-hydroxy-5,8,10,14 eicosatetraenoic acid (HETE), and arachidonic acid released from thrombin treated human platelets. Platelets were pre-labeled with 3H-arachidonic acid and then isolated by gel filtration. They were then exposed to thrombin for various intervals and separated by centrifugation. Aliquots of the cell-free medium were applied directly to a high pressure liquid chromatograph containing a fatty acid column as the stationary phase. A quarternary solvent system containing tetrahydrofuran (THF), acetonitrile (CH3CN), water and acetic acid (HOAC) resolved and eluted the arachidonic acid metabolites within 30 minutes. Since no sample preparation is required and since the solvent system does not quench the counting efficiency of a standard liquid scintillation fluor the technique permits rapid separation and quantitation of radiolabeled arachidonic acid and its metabolites.  相似文献   

9.
We have developed a technique for the rapid separation and quantitative collection of thromboxane B2 (TXB2), PGE2, PGD2, PGF, 12-hydroxy-5,8,10 heptadecatrienoic acid (HHT), 12-L-hydroxy-5,8,10,14 eicosatetraenoic acid (HETE), and arachidonic acid released from thrombin treated human platelets. Platelets were pre-labeled with 3H-arachidonic acid and then isolated by gel filtration. They were then exposed to thrombin for various intervals and separated by centrifugation. Aliquots of the cell-free medium were applied directly to a high pressure liquid chromatograph containing a fatty acid column as the stationary phase. A quarternary solvent system containing tetrahydrofuran (THF), acetonitrile (CH3CN), water and acetic acid (HOAC) resolved and eluted the arachidonic acid metabolites within 30 minutes. Since no sample preparation is required and since the solvent system does not quench the counting efficiency of a standard liquid scintillation fluor the technique permits rapid separation and quantitation of radiolabeled arachidonic acid and its metabolites.  相似文献   

10.
R Causon  D Davies  M Brown 《Life sciences》1987,41(7):909-912
Electrochemical detection of eluted solutes in HPLC is now well established as a selective and highly sensitive technique. Measurement of catecholamines and metabolites has been the most popular application with an exponential increase in literature. Recent improvements include the use of diphenylborate for extractions, the introduction of smaller diameter HPLC materials which improve resolution and sensitivity, and the replacement of carbon paste with glassy carbon which now gives a more stable electrode with similar sensitivity. Applications of HPLC with amperometric detection to the determination of drugs, amino acids and peptides are discussed.  相似文献   

11.
Phlebotomus ariasi Tonnoir sandflies were caught in light traps hung in oak trees and in a house in the Cévennes focus of leishmaniasis in the South of France. The flies were cryopreserved either immediately on removal from the traps, or after starvation for 6-7 days, or after 6-7 days starvation followed by exposure to oak infested with the aphid genera Lachnus or Thelaxes. After transportation to the laboratory, the sandflies were thawed and aqueous extracts of the crushed flies were analysed for their carbohydrate content using high performance liquid chromatography (HPLC) and gas chromatography (GC). Starved female sandflies lacked significant amounts of any saccharides. Four types of sugar, melezitose and its hydrolysis products turanose, glucose and fructose, were observed in flies which had been starved previously and then placed with Lachnus infested oak. The results also indicate the presence of hydrolysis products of melezitose: (a) in flies previously starved and placed with Thelaxes infested oak, (b) in P.ariasi cryopreserved direct from the light traps hung in oak trees infested with Lachnus and Thelaxes, and (c) flies caught in a house. Unidentifiably small quantities of a trisaccharide were also detected in the latter groups of flies. In previous tests, sugars were detected in P.ariasi after their exposure to aphid-infested oak (Quercus ilex L.), but not when P.ariasi females were exposed to washed oak leaves without aphids. The results indicate that P.ariasi feed on melezitose and/or turanose, the main local source of which is aphid honeydew. A better understanding of sugar meal sources of sandflies using HPLC and GC techniques will assist in our understanding of sandfly/Leishmania relationships, parasite transmission and epidemiology.  相似文献   

12.
Arachidonic acid metabolites exert a variety of distinct biological effects on the initiation and resolution of inflammatory diseases and their measurements in tissue can be critical to evaluate their regulatory function during the course of inflammation and to supplement in vitro experiments. The aim of this study was the detection and quantitative analysis of four arachidonic acid metabolites in small-sized biopsies of human periodontal tissues. The biopsies were homogenized and injected directly into a single analytical column of a RP-HPLC system. Detection was performed by a photodiode array detector. Calibration was established by dilutions of authentic standards of prostaglandin E2 (PGE2), leukotriene B4 (LTB4), 12(R)-hydroxy-5,8,10,14-eicosatetraenoic acid (12-HETE), and 15(S)-hydroxy-5,8,11,13-eicosatetraenoic acid (15-HETE). A total of 38 specimens weighing between 19 and 191 mg (wet tissue) were analyzed (mean = 59.9 +/- 30.2 mg). The detection limits were 1 pg for LTB4 and 12-HETE, 0.5 pg for 15-HETE, and 10 ng for PGE2. The concentrations of PGE2 and LTB4 were significantly higher in inflamed than in healthy periodontal tissues (P = 0.0079; P = 0. 0114). 12-HETE was detected in one biopsy (30 pg/g); 15-HETE was not detected. This method of homogenization, extraction, and analysis of arachidonic acid metabolites by RP-HPLC appears to be well suited for studies of human oral biopsies. Only small tissue samples and minimal laboratory equipment were required for a sensitive analysis.  相似文献   

13.
We have developed a method for the rapid separation of anionic oligosaccharide species by high-performance liquid chromatography utilizing a MicroPak AX-10 ion-exchange column (Varian Associates) with the mobile phase consisting of 25–500 mm KH2PO4, pH4.0. Separation of oligosaccharides bearing zero, one, two, three or four sialic acid residues requires less than 45 min. Oligosaccharides containing mannose-6-PO4 moieties in monoester or diester linkage can also be analyzed in this system. Preparative separations of as much as 20 mg of oligosaccharide can be accomplished in a single chromatographic analysis with quantitative yields of oligosaccharide. This method should prove useful for the rapid isolation and characterization of anionic oligosaccharide species.  相似文献   

14.
For the quantification of lipid hydroperoxides by high performance liquid chromatography (HPLC), it has been necessary to improve the detection system specific to the hydroperoxy group. We first developed a technique which combined detection by uv absorption due to conjugated diene and detection based on electrochemical (EC) reduction in reverse-phase HPLC for the selective determination of arachidonic acid hydroperoxides (hydroperoxyeicosatetraenoic acid, HPETE) and its reduced derivative, hydroxyeicosatetraenoic acid (HETE). 15-HPETE was quantified selectively by EC detection, although both 15-HPETE and 15-HETE were detected by uv absorption and were hardly resolved in the chromatogram. Isomers in HPETE obtained from autoxidized arachidonic acid were partially separated in the chromatogram and seem to have been quantified similarly to 15-HPETE. The application of this analytical system to the analysis of 15-HPETE added in human plasma has demonstrated that the recovery of HPETE extracted from human plasma is much lower than that from normal saline and that HPETE is reduced to HETE by incubation at 37 degrees C. The fact that a high concentration of glutathione accelerated this reduction may indicate that human plasma possesses a glutathione-dependent HPETE-reducing ability as a defense system against excess accumulation of lipid hydroperoxides. Blood plasma effectively suppressed the decomposition of HPETE induced by ferrous ion indicating the presence of factors which prevent the action of ferrous ion on HPETE.  相似文献   

15.
The major lipid classes in animal tissues, varying in polarity from cholesteryl esters to lysophosphatidylcholine, can be separated and accurately quantified by high performance liquid chromatography on a short 3-mu silica column and using a mass (light-scattering) detector. Sample sizes of 0.2 to 0.4 mg are optimum and the analysis is completed in only 20 min. The column is reactivated and ready for the next analysis after a further 10 min. After acid treatment, the plasmalogen forms of phospholipids can be determined. Applications of the procedure to the analysis of rat liver, heart, erythrocytes, and plasma lipids are described.  相似文献   

16.
An HPLC method for the separation and analysis of arachidonic acid and eight phospholipid classes is described: phosphatidylglycerol, phosphatidylinositol, cardiolipin, phosphatidylserine, phosphatidylethanolamine, phosphatidylcholine, sphingomyelin, and 2-lysophosphatidylcholine. The separation is carried out at 60 degrees C on 2 cyanopropyl columns using a gradient of acetonitrile and 5 mM sodium acetate (pH 5.0). Cyanopropyl columns require a lower proportion of water in the mobile phase to elute the more polar phospholipids than other types of columns and are thus less prone to equilibration problems. The method is highly reproducible (average coefficient of variation for each retention time less than or equal to 3.5%) and permits analysis of peaks by phosphorus content. Data obtained by analyzing lipid extracts from rat alveolar macrophages prelabeled with [G-3H]-arachidonic acid were analyzed by this HPLC method and compared to standard analysis by TLC. There was a significant correlation between the radioactivity profiles obtained with the two chromatographic methods (HPLC versus TLC) by linear regression analysis [HPLC = 0.83 (TLC) + 3.58, n = 25, r = 0.95, P less than 0.001].  相似文献   

17.
高效液相色谱分析银杏萜内酯的含量   总被引:2,自引:0,他引:2  
李典鹏  方宏  梁小燕  陈海珊  文永新   《广西植物》1999,19(3):282-284
用高效液相色谱法测定银杏叶及提取物中银杏内酯A、B、C和白果内酯的含量。采用C18分离柱,示差检测器,甲醇:水(33:67)为流动相,方法回收率平均达97%以上,变异系数(CV)为2.1%。  相似文献   

18.
Utilization of ion-air reagents in a reversed-phase chromatographic system allows solving a number of problems related to the separation of purine and pyrimidine derivatives. Simultaneous analysis of nucleotides, nucleosides and their bases was carried out by acetonitrile gradient elution using tetrabutyl ammonium phosphate as a counterion in the mobile phase. Besides, optimal conditions were selected for isocratic separation of adenine nucleotides and their metabolites. Furthermore, isocratic separation of certain purines and pyrimidines was achieved by modifying the stationary C18-phase with pentane- and heptane sulphonic acids.  相似文献   

19.
A high performance liquid chromatographic method is described for the rapid, non-destructive separation of a number of physiologically important steroidal estrogens, including the labile catechol estrogens. This procedures uses a "Diol" column and gradient elution to separate in a single run, estrogens ranging from 2-methoxy estrone, one of the least polar C18 steroids, to estriol, one of the most polar. Simpler, isocratic conditions, are provided for the separation of estrogens of similar polarity. A semi-preparative column of similar composition was used for the purification of samples containing 25 to 50 mg of individual steroids.  相似文献   

20.
HPLC resins containing nucleic acid base derivatives were successfully prepared. These resins were found to give excellent complementary separation of nucleic acid base derivatives, nucleosides, nucleotides, and oligonucleotides. These resins may be useful for separation of components of nucleic acids and polynucleotides as a specific separation system, while ion-exchange and reverse-phase systems are non-specific separation systems.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号