首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
I Popov  G Lewin 《Luminescence》2005,20(4-5):321-325
The method of photosensitized chemiluminescence (PCL) allows the quantification of water- and lipid-soluble antioxidants and activity of superoxide dismutase (SOD) in the same measuring system. However, it needs a special device, which we have described in a previous paper in this series. Another method suitable for the assay of water- and lipid-soluble antioxidants is the thermo-initiated decay of azo-compounds combined with the measurement of O2 consumption (Niki, 1985; Wayner et al., 1985). Its long duration and the complicated measuring procedure is not acceptable for routine medical applications. We show that a modification using CL detection of free radicals with luminol, has results comparable with PCL for the determination of non-enzymic water- and lipid-soluble antioxidants, SOD activity and oxidative modification of proteins. In contrast to PCL, it is possible to use any luminometer with a heatable measuring cell and to investigate coloured samples. While the new method has an overall higher sensitivity and is scalable to microtitre plates, PCL measurements can be made at different pH. The advantages and analytical information content of certain components of the integral antioxidative capacity of blood plasma are discussed in comparison with other methods.  相似文献   

2.
A sensitive chemiluminescent sandwich-type enzyme immunoassay for hen egg lysozyme was developed. The assay was performed on polystyrene microtitre plates using immobilized specific polyclonal rabbit antibody against lysozyme, a peroxidase conjugate and the H2O2/luminol-enhanced chemiluminescence detection reagent. The chemiluminescent signal was detected using either a microplate luminometer, or photographic film in a camera luminometer. The detection limit for lysozyme was 0.3 ng/mL, and this was three times lower than that obtained using a colorimetric method with H2O2 and o-phenylendiamine as substrates. Recovery of the assay was 97–112% and the relative standard deviation ranged from 3.6% to 10.3%. The immunoassay overcame interference from the food sample matrix when lysozyme, used as a bacteriostatic agent, was measured.  相似文献   

3.
Protein carbonylation is the most commonly used measure of oxidative modification of proteins. It is frequently measured spectrophotometrically or immunochemically by derivatizing proteins with the classical carbonyl reagent, 2,4-dinitrophenylhydrazine. We developed an immunochemical dot blot method for quantitation of protein carbonylation in homogenates or purified proteins. Dimethyl sulfoxide was employed as the solvent because it very efficiently extracts proteins from tissues and keeps them soluble. It also readily dissolves 2,4-dinitrophenylhydrazine and wets polyvinylidene difluoride (PVDF) membranes. The detection limit is 0.19 ± 0.04 pmol of carbonyl, and 60 ng of protein is sufficient to measure protein carbonyl content. This level of sensitivity allowed measurement of protein carbonylation in individual Drosophila.  相似文献   

4.
We describe here a sensitive new procedure for detecting DNA hybridization by dot blots. The method utilizes DNA or oligonucleotide probes labeled with biotin, sulfone, or haptens that can be detected by glucose-6-phosphate dehydrogenase (G6PDH) conjugates. Biotin labeling of DNA gave the best sensitivity. G6PDH activity was revealed by staining or by bioluminescence using an FMN oxidoreductase and a luciferase from Beneckea harveyi. Bioluminescent detection offered better sensitivity and faster revelation than the colorimetric assay and was found to be very useful in visualizing single mutations in human DNA after hybridization with an allele-specific biotinylated oligonucleotide probe. Revelation can be performed using a luminometer, photographic films, or a very sensitive video camera. The detection is limited by the nonspecific binding of the labeled reagent (streptavidin or antibodies). This limit is similar to that obtained with other nonisotopic labeling procedures, but our method is faster and several hybridization reactions can be performed on the same support.  相似文献   

5.
Fluorescent labeling of proteins was found to be a very sensitive and reliable alternative to conventional methods for monitoring proteins on Western blots. Proteins were labeled with 2-methoxy-2,4-diphenyl-3(2H)-furanone (MDPF) before SDS-PAGE. After electrophoresis and subsequent electro-blotting the fluorescent-labeled proteins were visible upon ultraviolet illumination of the nitrocellulose membranes, and could be photographed to yield an accurate record of the blots before subsequent serological analysis. The sensitivity for detecting MDPF-labeled proteins on nitrocellulose was 100-200 ng, 50 to 100 fold less sensitive than on gels. Fluorescent-labeled TMV and MStpV capsid proteins that were blotted onto nitrocellulose still reacted in serological tests and were detected when present in quantities as low as 100 pg. Fluorescent labeling allows accurate photographic records of the SDS-gel, blot and probed blot using only one sample, and no subsequent staining steps are required.  相似文献   

6.
A method for protein detection on nitrocellulose membranes based on modification with 2,4,6-trinitrobenzenesulfonic acid and reaction with anti-trinitrophenyl (TNP) serum as first antibody followed by peroxidase-conjugated second antibody is described. Protein quantities between 1 and 3 ng can be detected in the dot test. This method was used in a double immunodetection procedure after electrophoretic transfer of proteins localizing first a distinct antigen with its specific antiserum followed by visualization of the complete protein pattern on the same blot by the TNP/anti-TNP method as described above. As only water-soluble reagents are employed no shrinkage of the membrane occurs. Furthermore, the method can be used in a simultaneous immunodetection procedure visualizing the specific antigen together with TNP marker proteins using a mixture of the specific antiserum and the anti-TNP serum as first antibody.  相似文献   

7.
Recent developments in cellular and molecular biology require the accurate quantification of DNA and RNA in large numbers of samples at a sensitivity that enables determination on small quantities. In this study, five current methods for nucleic acid quantification were compared: (i) UV absorbance spectroscopy at 260 nm, (ii) colorimetric reaction with orcinol reagent, (iii) colorimetric reaction based on diphenylamine, (iv) fluorescence detection with Hoechst 33258 reagent, and (v) fluorescence detection with thiazole orange reagent. Genomic DNA of three different microbial species (with widely different G+C content) was used, as were two different types of yeast RNA and a mixture of equal quantities of DNA and RNA. We can conclude that for nucleic acid quantification, a standard curve with DNA of the microbial strain under study is the best reference. Fluorescence detection with Hoechst 33258 reagent is a sensitive and precise method for DNA quantification if the G+C content is less than 50%. In addition, this method allows quantification of very low levels of DNA (nanogram scale). Moreover, the samples can be crude cell extracts. Also, UV absorbance at 260 nm and fluorescence detection with thiazole orange reagent are sensitive methods for nucleic acid detection, but only if purified nucleic acids need to be measured.  相似文献   

8.
We describe herein the construction of a novel computerized multi-sample temperature-controlled luminometer for a fiber array-based biosensor to monitor circulating phagocyte activity. It can perform simultaneously integral measurements of chemiluminescence emitted from up to six samples containing less than 0.5 microl whole blood while the samples and detector do not change their position during the measurement cycle. The optical fibers in this luminometer are used as both light guides and solid phase sample holders. The latter feature of the instrument design simplifies the assessment process of both the extra-cellular and the intra-cellular parts of the phagocyte-emitted chemiluminescence using the same system. We describe some examples or proof of principle for the use of the biosensor. This new technology may find use in a wide range of analytical luminescence applications in biology, biophysics, biochemistry, toxicology and clinical medicine.  相似文献   

9.
Sensitive fluorescent detection of protein on nylon membranes   总被引:2,自引:0,他引:2  
Detection of antigen immobilized on membranes, as in Western transfers and dot enzyme linked immunosorbent assays (ELISAs), often employ antibody-enzyme conjugates and chemiluminescent or precipitated colored reaction products. Although chemiluminescent markers are sensitive, they are time-consuming because of their required exposure to X-ray film and the presence of background artifacts sometimes limits their use. This report demonstrates that direct fluorescent detection technique using nylon membranes that has higher sensitivity than chemiluminescent methods is easier to perform and has a uniform, low background. An alkaline phosphatase conjugated antibody was compared with antibody conjugated to a fluorescent phycobiliprotein (allophycocyanin) for sensitivity in both Western transfers and dot ELISA assays using mouse IgG as the membrane-bound antigen. Direct fluorescent detection of antigen-antibody complexes on positively charged nylon membrane provided better sensitivity and lower background than similar conditions using enzyme amplification and chemiluminescent detection on either nylon or PVDF membranes. Processing time was reduced by the elimination of steps associated with substrate incubation, washing and X-ray film exposures required for chemiluminescence detection. These data support the view that direct fluorescent detection can represent a significant improvement in assay sensitivity and reduction in time compared with more traditional chemiluminescent detection techniques employed in the conduct of Western transfers and dot ELISA studies.  相似文献   

10.
A novel isotopically labeled cysteine-tagging and complexity-reducing reagent, called HysTag, has been synthesized and used for quantitative proteomics of proteins from enriched plasma membrane preparations from mouse fore- and hindbrain. The reagent is a 10-mer derivatized peptide, H(2)N-(His)(6)-Ala-Arg-Ala-Cys(2-thiopyridyl disulfide)-CO(2)H, which consists of four functional elements: i) an affinity ligand (His(6)-tag), ii) a tryptic cleavage site (-Arg-Ala-), iii) Ala-9 residue that contains four (d(4)) or no (d(0)) deuterium atoms, and iv) a thiol-reactive group (2-thiopyridyl disulfide). For differential analysis cysteine residues in the compared samples are modified using either (d(4)) or (d(0)) reagent. The HysTag peptide is preserved in Lys-C digestion of proteins and allows charge-based selection of cysteine-containing peptides, whereas subsequent tryptic digestion reduces the labeling group to a di-peptide, which does not hinder effective fragmentation. Furthermore, we found that tagged peptides containing Ala-d(4) co-elute with their d(0)-labeled counterparts. To demonstrate effectiveness of the reagent, a differential analysis of mouse forebrain versus hindbrain plasma membranes was performed. Enriched plasma membrane fractions were partially denatured, reduced, and reacted with the reagent. Digestion with endoproteinase Lys-C was carried out on nonsolubilized membranes. The membranes were sedimented by ultra centrifugation, and the tagged peptides were isolated by Ni(2+) affinity or cation-exchange chromatography. Finally, the tagged peptides were cleaved with trypsin to release the histidine tag (residues 1-8 of the reagent) followed by liquid chromatography tandem mass spectroscopy for relative protein quantification and identification. A total of 355 unique proteins were identified, among which 281 could be quantified. Among a large majority of proteins with ratios close to one, a few proteins with significant quantitative changes were retrieved. The HysTag offers advantages compared with the isotope-coded affinity tag reagent, because the HysTag reagent is easy to synthesize, economical due to use of deuterium instead of (13)C isotope label, and allows robust purification and flexibility through the affinity tag, which can be extended to different peptide functionalities.  相似文献   

11.
A new biotin-containing reagent, p-diazobenzoyl biocytin (DBB), has been developed for labeling tyrosines and histidines in proteins. The reagent has used to label these residues in both model proteins and erythrocyte membrane proteins on dot blots and blot transfers. In some cases, sub-nanogram levels of individual proteins could be detected. The utility of DBB as a versatile alternative to biotin-containing N-hydroxysuccinimide esters for the general labeling of proteins is discussed.  相似文献   

12.
自制显示系统检测免疫印迹中的目的蛋白   总被引:1,自引:0,他引:1  
目前蛋白免疫印迹显示系统有显色法和化学发光法,因化学发光法具有灵敏、快速、准确等特点而倍受科研工作者的青睐,但一般商品化的化学发光试剂盒价格颇为昂贵,为此,在参考文献的基础上作了一些改进,将Tris Cl的pH值从7.5提高到11.0,同时提高了对碘苯酚的浓度(从1mmol/L提高到2mmol/L),得到了自制的化学发光试剂。首先用其检测了大肠杆菌中表达的2种不同分子量的蛋白(gam,13kDa;bet,30kDa),发现当蛋白上样量为2~20ng时,各蛋白条带均清晰显示。随后的斑点免疫印迹实验表明:自制及进口化学发光试剂在检测酶标二抗效价方面有着同样高的敏感性。  相似文献   

13.
A luminol-dependent chemiluminescence assay for the assessment of the phagocytosis of erythrocytes sensitized with anti-D IgG immunoglobulin by mononuclear leukocytes is described. The mononuclear leukocytes were obtained by apheresis enriched by centrifugation through a density gradient and stored in liquid nitrogen before use. The total reaction mixture, consisting of mononuclear leukocytes-luminol-erythrocytes (either anti-D IgG sensitized or unsensitized controls) was 500 μl, light detection was by an LKB 1251 luminometer. Peak luminescence was seen between 35–45 minutes, the reaction being exhausted by 120 minutes. Determination of the reproducibility of the assay gave intra- and inter-assay coefficients of variation of 5% and 13% respectively. We found the chemiluminescent response to be affected by the number of erythrocytes used in the assay and by the composition of the medium in which the cells were resuspended, particularly the pH at the initiation of the assay. We also compared the chemiluminescence assay to a microscopic phagocytic assay and found the results virtually identical. However, the former chemiluminescence assay was much easier to perform, marginally more sensitive, less laborious and eliminated any possibility of subjective error.  相似文献   

14.
目的:蛋白免疫印迹法自发明以来被广泛应用于现代生物学研究中的蛋白质定性和半定量分析。为了提高蛋白免疫印迹法的检测效率,需针对不同蛋白的特性调节相关的实验条件参数。本文旨在探讨免疫印迹法不同参数对小分子蛋白检测效果的影响,从而优化并获得最佳实验条件。方法:比较不同转膜电压和时间、转移缓冲液甲醇含量、不同化学发光剂对小分子蛋白的检测效果。结果:选择20 V、10 min转膜电压和时间所获得的信号显著高于10 V、25 min转膜条件,选择含20%甲醇转移缓冲液所获得的信号显著高于无甲醇转移缓冲液,选择飞克级化学发光剂所获得的信号显著高于纳克级化学发光剂。结论:选用高电压、短时间组合,选择含20%甲醇转移缓冲液和飞克级化学发光剂信号均有助于小分子蛋白免疫印迹检测。  相似文献   

15.
A rapid and simple chemiluminescence method was developed for detection of inosine and hypoxanthine in human plasma. The method utilized a microplate luminometer with direct injectors to automatically dispense reagents during sample analysis. Enzymatic conversions of inosine to hypoxanthine, followed by hypoxanthine to xanthine to uric acid, generated superoxide anion radicals as a useful metabolic by‐product. The free radicals react with Pholasin®, a sensitive photoprotein used for chemiluminescence detection, to produce measurable blue‐green light. The use of Pholasin® and a chemiluminescence signal enhancer, Adjuvant‐K?, eliminated the need for plasma clean‐up steps prior to analysis. The method used 20 μL of heparinized plasma, with complete analysis of total hypoxanthine levels (inosine is metabolized to hypoxanthine using purine nucleoside phosphorylase) in approximately 3.7 min. The rapid chemiluminescence method demonstrated the capability of differentiating total hypoxanthine levels between healthy individuals, and patients presenting with non‐traumatic chest pain and potential acute cardiac ischemia. The results support the potential use of chemiluminescence methodology as a diagnostic tool to rapidly screen for elevated levels of inosine and hypoxanthine in human plasma, potential biomarkers of acute cardiac ischemia.Copyright ©2009 John Wiley & Sons, Ltd.  相似文献   

16.
A specific, fast, and sensitive nonradioactive immunobinding assay for the detection and enumeration of the moderate thermophile Thiobacillus caldus and the thermophilic archaeon Sulfolobus acidocaldarius was developed. It employs enhanced chemiluminescence or peroxidase-conjugated immunoglobulins in a dot or slot blotting system and is very convenient for monitoring thermophilic bioleaching microorganisms in effluents from industrial bioleaching processes.  相似文献   

17.
A colorimetric method for the detection of gamma-carboxyglutamic acid (Gla)-containing proteins after reaction with 4-diazobenzenesulfonic acid is presented. Proteins can be visualized after electroblotting from polyacrylamide gels onto membrane supports, after dot-blotting onto membranes, or in solution as a red colored product with an absorbance maximum at 530 nm. The method is specific since other proteins without gamma-carboxyglutamic acid do not form a red color. The presence of other proteins does not inhibit or affect color production by gamma-carboxyglutamic acid-containing proteins. Application of the method for staining a Western blot of a crude extract of bone resulted in staining of only the gamma-carboxyglutamic acid-containing proteins. The usefulness of the method was verified when a second gamma-carboxyglutamic acid-containing protein, prothrombin, also resulted in red color production. A linear color response is seen up to 17 microM for the gamma-carboxyglutamic acid-containing protein bone Gla protein and up to 27 microM for the amino acid. The detection limit is down to 1 microgram of bone Gla protein or 0.17 nmol of the protein on electroblots or dot blots. The simplicity of the method allows rapid screening for gamma-carboxyglutamic acid-containing proteins or allows monitoring of purifications of these proteins in chromatographic or electrophoretic separations.  相似文献   

18.
A dot immunobinding ("dot blot") method for measuring uncoupling protein in brown adipose tissue mitochondria is described. Mitochondrial proteins were solubilized in sodium dodecyl sulfate and applied directly to a nitrocellulose membrane housed in a 96-well microfiltration manifold. Spare binding sites on the nitrocellulose membrane were blocked with bovine serum albumin and then anti-(uncoupling protein) serum was applied. The antigen-antibody complex was detected by the addition of 125I-labelled protein A. Each nitrocellulose "dot" was cut out and its radioactivity was counted. A calibration curve was constructed from purified uncoupling protein standards, taken through the entire procedure. The dot immunobinding method is sensitive (nanogram quantities of uncoupling protein), and in contrast to conventional radioimmunoassay and enzyme-linked immunosorbent assay procedures, it is also rapid and appears to be very robust. The method has been successfully applied to the measurement of uncoupling protein in brown adipose tissue mitochondria of Richardson's ground squirrel, rats, and mice.  相似文献   

19.
Simple Western is a new technology that allows for the separation, blotting, and detection of proteins similar to a traditional Western except in a capillary format. Traditionally, identity assays for biological products are performed using either an enzyme-linked immunosorbent assay (ELISA) or a manual dot blot Western. Both techniques are usually very tedious, labor-intensive, and complicated for multivalent vaccines, and they can be difficult to transfer to other laboratories. An advantage this capillary Western technique has over the traditional manual dot blot Western method is the speed and the automation of electrophoresis separation, blotting, and detection steps performed in 96 capillaries. This article describes details of the development of an automated identity assay for a 15-valent pneumococcal conjugate vaccine, PCV15–CRM197, using capillary Western technology.  相似文献   

20.
Two independent radioimmunoassay techniques for the major phenobarbital-inducible cytochrome P-450 (PB P-450) of rat liver microsomal membranes are described. The first technique employs as the source of radiolabelled antigen the products of translation in vitro labelled with [35S]methionine. The second technique employs purified antigen labelled with 125I and is quicker, less expensive and more precise. Both assays are highly specific for PB P-450 and can detect quantities of this variant as small as 1 ng. This is several orders of magnitude more sensitive than any method described previously for the quantification of cytochromes P-450, and consequently the technique is particularly well suited for the quantification of so-called constitutive cytochrome P-450 variants that are present in very low amounts. The results of the radioimmunoassays demonstrate that the apparent 2.6-fold induction of total cytochromes P-450 after phenobarbital treatment is due to a 43-fold increase in Pb P-450. Although beta-naphthoflavone increases the total content of cytochrome P-450 of microsomal membranes 1.4-fold, it actually causes a 55% decrease in the amount of PB P-450. Thus different xenobiotics can have differential effects on the expression of the genes for specific cytochrome P-450 variants.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号