首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The postoperative outcome of hand flexor tendon repair remains limited by tendon adhesions that prevent normal range of motion. Recent studies using in situ hybridization techniques have implicated transforming growth factor beta-1 (TGF-beta1) in both intrinsic and extrinsic mechanisms of repair. TGF-beta1 is a growth factor that plays multiple roles in wound healing and has also been implicated in the pathogenesis of excessive scar formation. The purpose of this study was to examine the effect of neutralizing antibody to TGF-beta1 in a rabbit zone II flexor tendon wound-healing model. Twenty-two adult New Zealand White rabbits underwent complete transection of the middle digit flexor digitorum profundus tendon in zone II. The tendons were immediately repaired and received intraoperative infiltration of one of the following substances: (1) control phosphate-buffered saline; (2) 50 microg neutralizing antibody to TGF-beta1; (3) 50 microg each of neutralizing antibody to TGF-beta1 and to TGF-beta2. Eight rabbits that had not been operated on underwent analysis for determination of normal flexion range of motion at their proximal and distal interphalangeal joints, using a 1.2-N axial load applied to the flexor digitorum profundus tendon. All rabbits that had been operated on were placed in casts for 8 weeks to allow maximal tendon adhesion and were then killed to determine their flexion range of motion. Statistical analysis was performed using the Student's unpaired t test. When a 1.2-N load was used on rabbit forepaws that had not been operated on, normal combined flexion range of motion at the proximal and distal interphalangeal joints was 93+/-6 degrees. Previous immobilization in casts did not reduce the range of motion in these forepaws (93+/-4 degrees). In the experimental groups, complete transection and repair of the flexor digitorum profundus tendon with infiltration of control phosphate-buffered saline solution resulted in significantly decreased range of motion between the proximal and distal phalanges [15+/-6 degrees (n = 8)]. However, in the tendon repairs infiltrated with neutralizing antibody to TGF-beta1, flexion range of motion increased to 32+/-9 degrees (n = 7; p = 0.002). Interestingly, a combination of neutralizing antibody to TGF-beta1 and that to TGF-beta2 did not improve postoperative range of motion [18+/-4 degrees (n = 7; p = 0.234)]. These data demonstrate that (1) the rabbit flexor tendon repair model is useful for quantifying tendon scar formation on the basis of degrees of flexion between proximal and distal phalanges; (2) intraoperative infiltration of neutralizing antibody to TGF-beta1 improves flexor tendon excursion; and (3) simultaneous infiltration of neutralizing antibody to TGF-beta2 nullifies this effect. Because TGF-beta1 is thought to contribute to the pathogenesis of excessive scar formation, the findings presented here suggest that intraoperative biochemical modulation of TGF-beta1 levels limits flexor tendon adhesion formation.  相似文献   

2.
BackgroundVarious surgical techniques for treating avulsions of the flexor digitorum profundus tendon at the distal phalanx have been published but no ideal technique has emerged. We introduce a new all-internal 4-anchor flexor tendon repair technique and evaluate outcomes in three clinical cases.MethodsIn this retrospective case series, we reviewed three patients that sustained an avulsion of the flexor digitorum profundus tendon at the distal phalanx. All patients were surgically treated with the four-anchor repair technique. Two titanium anchors were inserted into the distal phalanx and two all-suture anchors were inserted distal to the first set of anchors. The tendon was then attached to these four anchors using a Krackow stitch pattern and the anchors were sown to each other. Active flexion and extension of the proximal and distal interphalangeal joint were measured at 3-month, 12-month, and 5-year follow-up. Postoperative complications were documented.ResultsAll patients achieved excellent clinical outcomes according to assessment criteria. At 3-month follow-up, all patients regained full flexion; two patients had full extension, while one patient was 3 degrees short of full extension. At 12-month follow-up, all patients had full flexion and extension. Five-year follow-up demonstrated the same results with no loss of function, sensation or grip strength. The repairs healed without rupture, and no complications were reported.ConclusionThe 4-anchor flexor tendon repair is a viable surgical technique for zone 1 flexor digitorum profundus tendon repair or reconstruction. Further studies are needed to replicate these promising results and biomechanically validate this technique.Level of Evidence: IV  相似文献   

3.
Adhesion between the tendon and tendon sheath after primary flexor tendon repair is seen frequently, and postoperative finger function is occasionally unsatisfactory. A reduction of the friction may facilitate tendon mobilization, which in turn may reduce the risk of the adhesion and restriction of range of motion. We considered the possibility of utilizing the hyaluronic acid (HA) as a lubricant. To evaluate the effect of HA, the gliding resistance between the canine flexor digitorum profundus tendon repaired by a modified Kessler suture technique with running epitendinous suture and the annular pulley located on the proximal phalanx (corresponding to the A2 pulley in humans) was evaluated and compared before and after administration of HA. The HA solution measurement groups were identified as follows; intact tendon as a control; repaired tendon; tendon soaked in 0.1, 1, and 10 mg/ml HA. The resistance increased after repairing, then it decreased after soaking in 10 mg/ml HA solution. The results of this study revealed that HA diminishes the excursion resistance after flexor tendon repair. We believe that some style of administration of the HA might reduce the excursion resistance and prevent adhesion until the synovial surface is fully developed.  相似文献   

4.
Analysis of cumulative strain in tendons and tendon sheaths   总被引:4,自引:1,他引:3  
Twenty-five fresh frozen flexor digitorum profundus tendons stratified by sex were subjected to uniaxial step stress and cyclic loads in twelve intact human cadaver hands. By attaching specially designed clip strain gage transducers on tendons just proximal and distal to an undisrupted carpal tunnel, the interactions of the tendons, tendon sheath and retinacula were measured. The elastic and viscous response of the tendon composites to step stresses were found to fit fractional power functions of stress and time respectively. A significant and quantifiable decrease in strain from the proximal to the distal tendon segment was found to be a function of wrist deviation. The results indicate that an accumulation of strain does occur in tendinous tissues during physiologic loading.  相似文献   

5.
Exposure and infection of a Gore-Tex vascular access graft often results in removal of the graft. Salvage of the graft is possible, however, with the use of well-vascularized muscle flaps. In 1982, Hodgkinson was the first to use a sublimis muscle flap to cover an exposed vascular access graft. We used the flexor carpi ulnaris and flexor digitorum superficialis to cover exposed Gore-Tex grafts in nine patients. The sublimis was used to cover distal graft exposures, and the longer flexor carpi ulnaris muscle was used to cover more proximal sites. Multiple exposures required both flaps or combinations of muscle flaps and local rotation flaps. Eight of nine chronically exposed grafts were salvaged using these techniques; a graft was removed from one patient because of diffuse unrecognized graft bed infection. Disability is minimized by using only part of the sublimis, and loss of the flexor carpi ulnaris is compensated by local muscles with similar actions. Vascular puncture can be continued during healing.  相似文献   

6.
For the extrinsic hand flexors (flexor digitorum profundus, FDP; flexor digitorum superficialis, FDS; flexor pollicis longus, FPL), moment arm corresponds to the tendon's distance from the center of the metacarpalphalangeal (MP), proximal interphalangeal (PIP), or distal interphalangeal (DIP) joint. The clinical value of establishing accurate moment arms has been highlighted for biomechanical modeling, the development of robotic hands, designing rehabilitation protocols, and repairing flexor tendon pulleys (Brand et al., 1975; An et al., 1983; Thompson and Giurintano, 1989; Deshpande et al., 2010; Wu et al., 2010). In this study, we define the moment arms for all of the extrinsic flexor tendons of the hand across all digital joints for all digits in cadaveric hands.  相似文献   

7.
At a greater number of humid preparated human hands, all the ligamentous supports of the digital tendon sheath were exposed and their dimensions were determined. The osteofibrous channels, which contain the long flexor tendons of the digits, were bounded on the one hand by transversely concave shaft areas of the phalanges and the palmar ligaments and on the other side by the fibrous parts of the tendon sheath. From the second to the 5th finger, it has a regular extension of length, which begins proximal at the heads of the metacarpal bones and runs distal to the base of the nail phalanx. In some cases, there is a continuous communication between the digital tendon sheath of the little finger and the carpal synovial sheath. The tendon sheath of the flexor pollicis longus muscle in comparison with it is always in an open communication with the radial synovial sac of the wrist. At the fibrous supports of the digital tendon sheath, one can find constant and inconstant ligamentous structures. Regular shaped ligaments consist of annular fibers (A1 to A5). The proximal complex of fiber supports is a formation of the A1 and A2 ligaments. The band A1 can be divided into 2 ligaments both of roughly equal length, which lay between the head of the metacarpal bone and the base of the proximal phalanx. The strongest fibrous support of the whole digital tendon sheath represents the band A2. It is attached to the midth of the proximal phalanx and increases in strength from proximal to distal. The middle length varies between 6.7 mm at the thumb and 18.7 mm at the middle finger. The distal margin is strengthened by fibrocartilage tissue to be in accordance with the important function as a pulley. The annular band A4 forms the distal supporting complex height above the shaft of the middle phalanx. At the 2nd to the 5th finger it is, with a middle length of 6 to 7 mm, very much shorter than A2 and restrains first of all the tendon of the flexor digitorum profundus muscle. In the area of the interphalangeal joints, we can find the annular bands A3 and A5, which fiber texture is formed variable. Both ligaments are attached on either both sides with the joint capsule and the palmar plate. The other inconstant supports of the digital sheaths are systematically recorded indeed (C1 to C3), but only in exceptional cases they exist of cruciform fibers (Lig. cruciatum).(ABSTRACT TRUNCATED AT 400 WORDS)  相似文献   

8.
Rock climbers are often using the unique crimp grip position to hold small ledges. Thereby the proximal interphalangeal (PIP) joints are flexed about 90 degrees and the distal interphalangeal joints are hyperextended maximally. During this position of the finger joints bowstringing of the flexor tendon is applying very high load to the flexor tendon pulleys and can cause injuries and overuse syndromes. The objective of this study was to investigate bowstringing and forces during crimp grip position. Two devices were built to measure the force and the distance of bowstringing and one device to measure forces at the fingertip. All measurements of 16 fingers of four subjects were made in vivo. The largest amount of bowstringing was caused by the flexor digitorum profundus tendon in the crimp grip position being less using slope grip position (PIP joint extended). During a warm-up, the distance of bowstringing over the distal edge of the A2 pulley increased by 0.6mm (30%) and was loaded about 3 times the force applied at the fingertip during crimp grip position. Load up to 116N was measured over the A2 pulley. Increase of force in one finger holds by the quadriga effect was shown using crimp and slope grip position.  相似文献   

9.
Formation of restrictive adhesions is one of the main obstacles in rehabilitation following hand surgery. Most experimental work, however, involves only a macroscopic and/or histologic evaluation of the amount of adhesions, and their functional characteristics are poorly described. The aim of this study was to develop an experimental technique for characterization of the biomechanical properties of the finger-tendon unit. An instrument was developed for continuous and simultaneous recording of tensile load, tendon excursion and angular rotation in the distal interphalangeal joint of rabbit digits. Utilizing this instrument, it was revealed that the first 50 degrees of flexion required virtually no tensile load either in unoperated digits or immediately after tenorrhaphy. Thereafter, the load required to obtain further flexion was progressively increased. The strength of adhesions, determined 2 weeks after tenorrhaphy, was best expressed as the maximum tensile load recorded before 50 degrees of flexion was reached. This measurement could also be used to register the strength of the tendon repair and to detect partial tendon rupture during the measurement. The technique allows both adequate measurements of the strength of the adhesions and of the tendon gliding ability after flexor tendon surgery.  相似文献   

10.
The multi-joint model is a kinematic simulation of the long flexor tendons of the fingers. The tendons modeled are the flexor pollicis longus, the flexor digitorum profundus, and the flexor digitorum superficialis. The simulated tendons are displayed on an Evans and Sutherland PS330 color graphics terminal attached to a display of articulated bones of the hand. As a user changes the position of the joints of the simulated hand, the simulation displays the new tendon path and the excursion of the tendon for the new position of the hand. The multi-joint model is one component of a comprehensive model for use in a hand biomechanics computer workstation.  相似文献   

11.
Although we sometimes use the intrasynovial tendon allograft as a donor, the gliding ability of allograft prepared by lyophilization is significantly decreased. The gliding ability of the grafted tendon after tendon reconstruction is very important because the high gliding resistance causes more adhesion and leads to poor clinical results. We recently revealed that tendon surface treatment with a carbodiimide derivatized HA (cd-HA)-gelatin mixture for intrasynovial tendon allograft significantly improved its gliding ability. The purpose of this study was to investigate whether this cd-HA-gelatin treatment affects the tendon mechanical property or not. A total of 40 flexor digitorum profundus (FDP) tendons from canines were evaluated for compressive property by using indentation test. Indentation stiffness was measured for normal tendon, rehydrated tendon after lyophilization, rehydrated tendon after lyophilization that was implanted 6 weeks in vivo, and cd-HA treated rehydrated tendon after lyophilization that was implanted 6 weeks in vivo. The results for all groups showed no significant difference in the tendon compressive properties. The findings of these results demonstrate that cd-HA treatment for intrasynovial tendon allograft is an excellent method to improve the tendon gliding ability after lyophilization without changing the compressive property of donor tendon.  相似文献   

12.
Flexor tendon repair in zone II is complicated by adhesions that impair normal postoperative gliding. Transforming growth factor-beta (TGF-beta) is a family of growth factors that has been implicated in scar formation. The TGF-beta family of proteins binds to three distinct classes of membrane receptors, termed RI, RII, and RIII. In this study, we analyzed the temporal and spatial distribution of TGF-beta receptor isoforms (RI, RII, and RIII) in a rabbit zone II flexor tendon wound healing model.Twenty-eight adult New Zealand White rabbit forepaws underwent isolation of the middle digit flexor digitorum profundus tendon in zone II. The tendons underwent transection in zone II and immediate repair. The tendons were harvested at increasing time points: 1, 3, 7, 14, 28, and 56 days postoperatively (n = 4 at each time point). The control flexor tendons were harvested without transection and repair (n = 4). Immunohistochemical analysis was used to detect the expression patterns for TGF-beta receptors RI, RII, and RIII.Immunohistochemical staining of the transected and repaired tendons demonstrated up-regulation of TGF-beta RI, RII, and RIII protein levels. TGF-beta receptor production in the experimental group (transection and repair) was concentrated in the epitenon and along the repair site. Furthermore, the TGF-beta receptor expression levels peaked at day 14 and decreased by day 56 postoperatively. In contrast, minimal receptor expression was observed in the untransected and unrepaired control tendons.These data provide evidence that (1) TGF-beta receptors are up-regulated after injury and repair; (2) peak levels of TGF-beta receptor expression occurred at day 14 and decreased by day 56 after wounding and repair; and (3) both the tendon sheath and epitenon have the highest receptor expression, and both may play critical roles in flexor tendon wound healing. Understanding the up-regulation of TGF-beta isoforms and the up-regulation of their corresponding receptors during flexor tendon wound healing provides new targets for biomolecular modulation of postoperative scar formation.  相似文献   

13.
Tendon defects remain a major concern in plastic surgery because of the limited availability of tendon autografts. Whereas immune rejection prohibits the use of tendon allografts, most prosthetic replacements also fail to achieve a satisfactory long-term result of tendon repair. The tissue engineering technique, however, can generate different tissues using autologous cells and thus may provide an optimal approach to address this concern. The purpose of this study was to test the feasibility of engineering tendon tissues with autologous tenocytes to bridge a tendon defect in either a tendon sheath open model or a partial open model in the hen. In a total of 40 Leghorn hens, flexor tendons were harvested from the left feet and were digested with 0.25% type II collagenase. The isolated tenocytes were expanded in vitro and mixed with unwoven polyglycolic acid fibers to form a cell-scaffold construct in the shape of a tendon. The constructs were wrapped with intestinal submucosa and then cultured in Dulbecco's Modified Eagle Medium plus 10% fetal bovine serum for 1 week before in vivo transplantation. On the feet, a defect of 3 to 4 cm was created at the second flexor digitorum profundus tendon by resecting a tendon fragment. The defects were bridged either with a cell-scaffold construct in the experimental group ( n= 20) or with scaffold material alone in the control group ( n= 20). Specimens were harvested at 8, 12, and 14 weeks postrepair for gross and histologic examination and for biomechanical analysis. In the experimental group, a cordlike tissue bridging the tendon defect was formed at 8 weeks postrepair. At 14 weeks, the engineered tendons resembled the natural tendons grossly in both color and texture. Histologic examination at 8 weeks showed that the neo-tendon contained abundant tenocytes and collagen; most collagen bundles were randomly arranged. The undegraded polyglycolic acid fibers surrounded by inflammatory cells were also observed. At 12 weeks, tenocytes and collagen fibers became longitudinally aligned, with good interface healing to normal tendon. At 14 weeks, the engineered tendons displayed a typical tendon structure hardly distinguishable from that of normal tendons. Biomechanical analysis demonstrated increased breaking strength of the engineered tendons with time, which reached 83 percent of normal tendon strength at 14 weeks. In the control group, polyglycolic acid constructs were mostly degraded at 8 weeks and disappeared at 14 weeks. However, the breaking strength of the scaffold materials accounted for only 9 percent of normal tendon strength. The results of this study indicated that tendon tissue could be engineered in vivo to bridge a tendon defect. The engineered tendons resembled natural tendons not only in gross appearance and histologic structure but also in biomechanical properties.  相似文献   

14.
A program of controlled motion following repair of flexor tendons in the hand is presented. This regimen incorporates the features of active extension against rubber band passive flexion, as well as those of controlled passive extension and passive flexion. In this prospective study, 44 digits with complete lacerations of the flexor digitorum profundus and flexor digitorum superficialis in zone 2 were treated. Using the Strickland formula of total active motion of the interphalangeal joints, 36 fingers (82 percent) were rated "excellent"; 7 fingers (16 percent) were rated "good"; 1 finger (2 percent) was rated "fair"; none was rated "poor". There was no statistical difference between the results of delayed primary repair and immediate primary repair.  相似文献   

15.
Flexor tendons function as energy storage and shock absorption structures in the tarsometatarso‐phalangeal joint (TMTPJ) of ostrich feet during high‐speed and heavy‐load locomotion. In this study, mechanisms underlying the energy storage and shock absorption of three flexor tendons of the third toe were studied using histology and scanning electron microscopy (SEM). Macroscopic and microscopic structures of the flexor tendons in different positions of TMTPJ were analyzed. Histological slices showed collagen fiber bundles of all flexor tendons in the middle TMTPJ were arranged in a linear‐type, but in the proximal and distal TMTPJ, a wavy‐type arrangement was found in the tendon of the M. flexor digitorum longus and tendon of the M. flexor perforans et perforatus digiti III, while no regular‐type was found in the tendon of the M. flexor perforatus digiti III. SEM showed that the collagen fiber bundles of flexor tendons were arranged in a hierarchically staggered way (horizontally linear‐type and vertically linear‐type). Linear‐type and wavy‐type both existed in the proximal TMTPJ for the collagen fiber bundles of the tendon of the M. flexor perforatus digiti III, but only the linear‐type was found in the distal TMTPJ. A number of fibrils were distributed among the collagen fiber bundles, which were likely effective in connection, force transmission and other functions. The morphology and arrangement of collagen fiber bundles were closely related to the tendon functions. We present interpretations of the biological functions in different positions and types of the tendons in the TMTPJ of the ostrich feet.  相似文献   

16.
A device was designed to create clinically relevant, precise partial flexor digitorum profundus tendon lacerations for in vitro studies but can be adapted for in vivo studies. This caliper-based system utilizes a direct measurement of the tendon height and assumes an elliptical cross section to select the depth of the cut. The accuracy was tested on 60 cuts on 12 human tendons lacerated to an expected 50% or 75% of their cross-sectional area, based on the assumption that the cross-section was elliptical in shape. The cuts were made in portions of the tendon that varied in cross-sectional shape and size. The cut surface of the laceration was colored with Methylene blue and then the laceration was completed. The tendon cross-section was digitally imaged and the respective areas of the stained and unstained regions were evaluated using image-processing software. The mean lacerated areas were 52% (SD 5%) and 73% (SD 6%) for targeted lacerations of 50% and 75%, respectively. The device thus appears to be accurate within an acceptable 5% margin of error from the expected area, and adaptable to intra- and inter-tendinous size variations.  相似文献   

17.
A review of all flexor tendon repairs in the "no man's land" performed from January of 1985 to June of 1987 was done to evaluate the efficacy of our method of rehabilitation. There were 60 fingers (57 patients) with complete laceration of the flexor digitorum profundus and flexor digitorum superficialis tendons in zone II. Fingers with phalangeal fractures, joint injuries, or significant skin loss were excluded. Follow-up ranged from 12 to 48 months. Rehabilitation consisted of a 12-week protocol using the U.S. military combined regimen of controlled motion. Features from the technique of controlled active extension against rubber band passive flexion as well as those of controlled passive extension and passive flexion were incorporated. The palmar pulley modification of Kleinert's dynamic traction splint was utilized. Strickland's total active motion formula was employed to determine results. The results were classified into the four categories of excellent, good, fair, and poor. Fifty-two fingers (86 percent) were rated excellent, 4 fingers (7 percent) were rated good, 1 finger (2 percent) was rated fair, and 3 fingers (5 percent) were rated poor.  相似文献   

18.
This study evaluated the impact of a new half hitch loop suture configuration on flexor tendon repair mechanics. Cadaver canine flexor digitorum profundus tendons were repaired with 4- or 8-strands, 4–0 or 3–0 suture, with and without half hitch loops. An additional group underwent repair with half hitch loops but without the terminal knot. Half hitch loops improved the strength of 8-strand repairs by 21% when 4–0, and 33% when 3–0 suture was used, and caused a shift in failure mode from suture pullout to suture breakage. 8-strand repairs with half hitch loops but without a terminal knot produced equivalent mechanical properties to those without half hitch loops but with a terminal knot. 4-strand repairs were limited by the strength of the suture in all groups and, as a result, the presence of half hitch loops did not alter the mechanical properties. Overall, half hitch loops improved repair mechanics, allowing failure strength to reach the full capability of suture strength. Improving the mechanical properties of flexor tendon repair with half hitch loops has the potential to reduce the postoperative risk of gap formation and catastrophic rupture in the early postoperative period.  相似文献   

19.
We sought to describe the comparative anatomy of the Achilles tendon in rabbits and humans by using macroscopic observation, magnetic resonance imaging, and ultrasonography. The calcaneus-Achilles tendon-gastrocnemius-soleus complexes from 18 New Zealand white rabbits underwent ultrasound (US) and magnetic resonance (MR) imaging and gross anatomic sectioning; these results were compared with those from a cadaveric gastrocnemius-soleus-Achilles tendon-calcaneus specimen from a 68-y-old human male. The medial and lateral gastrocnemius muscle tendons merged 5.2 +/- 0.6 mm proximal to the calcaneal insertion macroscopically, at 93% of their course, different from the gastrocnemius human tendons, which merged at 23% of their overall course. The rabbit flexor digitorum superficialis tendon, corresponding to the flexor digitorum longus tendon in human and comparable in size with the gastrocnemius tendons, was located medial and anterior to the medial gastrocnemius tendon proximally and rotated dorsally and laterally to run posterior to the Achilles tendon-calcaneus insertion. In humans, the flexor digitorum longus tendon tracks posteriorly to the medial malleolus. The soleus muscle and tendon are negligible in the rabbit; these particular comparative anatomic features in the rabbit were confirmed on the MR images. Therefore the rabbit Achilles tendon shows distinctive gross anatomical and MR imaging features that must be considered when using the rabbit as a research model, especially for mechanical testing, or when generalizing results from rabbits to humans.  相似文献   

20.
Rather than the usual mammalian scheme in which tendon and sheath surfaces provide as little friction as possible, the tendons and sheaths of many bats have a locking segment on the manual and pedal flexor tendon complex. This tendon locking mechanism (TLM) exists opposite the proximal phalanges of each toe and pollex of many bats. Its structure, similar to a ratchet mechanism, assists bats in hanging with little muscular effort. The third digit of the pelvic limb and the pollex of species representing 15 chiropteran families were studied to determine the presence or absence, morphology, and function of the TLM. Most of the species studied have a TLM consisting of a patch of tubercles on the ventral surface of the flexor tendon associated with the proximal phalanx of each pollex or toe. The sheath adjacent to this portion of the flexor tendon has a series of transverse folds or ridges, which, when engaged with the tubercles on the tendon, lock the tendon in place. The TLM is similar in megachiropterans and microchiropterans possessing it. The TLM is absent, however, in some of the microchiropterans studied, most notably in the phyllostomids. Since many birds have a TLM similar to that of bats, it is an excellent example of the convergent evolution of a feature brought about by similar functional pressures on birds and bats. © 1993 Wiley-Liss, Inc.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号