首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
An average follow-up period of 16 patients was 28 months following an implantation of the artificial aortic valve for its insufficiency. In 10 operated patients who were able to continue their occupation exercise tolerance increased by two classes, according to NYHA. Blood pressure gradient decreased significantly from 61.8 to 37.5 mmHg, cardiac volume index decreased from 639 to 602 ml/m2. Echocardiographically measured muscle mass of the left ventricle, end-diastolic and end-systolic volumes, and the left atrial dimensions decreased significantly following surgery. A significance of the relation of the left ventricle volume to its mass <4 as a prognostic factor in aortic valve replacement has also been confirmed.  相似文献   

2.
Two Jehovah's Witnesses with large ascending thoracic aortic aneurysms and aortic insufficiency secondary to annuloaortic ectasia underwent successful combined replacement of the aortic valve and the ascending aorta. One patient received a composite graft containing an aortic valve prosthesis, which necessitated supravalvular coronary ostia reimplantation; the other patient underwent separate aortic valve and left supracoronary ascending aneurysm replacement, with reimplantation of the right coronary ostium into the graft. No blood or blood derivatives were administered. Both patients had uneventful recoveries and continue to do well. To our knowledge, they represent the first reported cases of successful combined replacement of the aortic valve and ascending aorta in Jehovah's Witnesses.  相似文献   

3.
In patients with aortic stenosis, the left ventricular afterload is determined by the degree of valvular obstruction and the systemic arterial system. We developed an explicit mathematical model formulated with a limited number of independent parameters that describes the interaction among the left ventricle, an aortic stenosis, and the arterial system. This ventricular-valvular-vascular (V(3)) model consists of the combination of the time-varying elastance model for the left ventricle, the instantaneous transvalvular pressure-flow relationship for the aortic valve, and the three-element windkessel representation of the vascular system. The objective of this study was to validate the V(3) model by using pressure-volume loop data obtained in six patients with severe aortic stenosis before and after aortic valve replacement. There was very good agreement between the estimated and the measured left ventricular and aortic pressure waveforms. The total relative error between estimated and measured pressures was on average (standard deviation) 7.5% (SD 2.3) and the equation of the corresponding regression line was y = 0.99x - 2.36 with a coefficient of determination r(2) = 0.98. There was also very good agreement between estimated and measured stroke volumes (y = 1.03x + 2.2, r(2) = 0.96, SEE = 2.8 ml). Hence, this mathematical V(3) model can be used to describe the hemodynamic interaction among the left ventricle, the aortic valve, and the systemic arterial system.  相似文献   

4.
目的:总结二尖瓣置换术后左心室破裂2例临床经验教训,方法:回顾性分析我院2006,1.2009,12二尖瓣置换术后左心室破裂2例的临床资料,两例均在监护室里发生突然大出血,紧急输血,输液,机械呼吸,抗休克治疗,并行开胸手术。结果:一例心外修补抢救成功,术后2周顺利出院,一例CPB下心内外修补,因低心排综合症死亡。结论:左心室破裂是二尖瓣置换术最严重的并发症,一旦发生死亡率极高,因此预防,避免其相关因素更关键:  相似文献   

5.
Left heart catheterization using the transbronchial route to obtain pressures in the left atrium and left ventricle was used successfully in 29 cases with no mortality or morbidity. It was found to be useful in differentiating between mitral stenosis and mitral insufficiency, as well as determining the amount of aortic stenosis present when there was involvement of the aortic valve. The technique was also helpful in determining which is the predominant lesion when there is a disease of the aortic and mitral valves.In two patients in a series of 29, data obtained by left heart catheterization forestalled operation on the basis of a mistaken diagnosis of mitral stenosis when actually no mitral valvular disease was present. In another eight patients, the predominant lesion was found to be mitral stenosis rather than mitral insufficiency as it was thought to be before catheterization. In two patients, who had only systolic murmurs, catheterization revealed mitral stenosis rather than mitral insufficiency. In four patients who were thought to have mixed valvular disease, left heart catheterization showed only aortic valvular disease.  相似文献   

6.
Left heart catheterization using the transbronchial route to obtain pressures in the left atrium and left ventricle was used successfully in 29 cases with no mortality or morbidity. It was found to be useful in differentiating between mitral stenosis and mitral insufficiency, as well as determining the amount of aortic stenosis present when there was involvement of the aortic valve. The technique was also helpful in determining which is the predominant lesion when there is a disease of the aortic and mitral valves. In two patients in a series of 29, data obtained by left heart catheterization forestalled operation on the basis of a mistaken diagnosis of mitral stenosis when actually no mitral valvular disease was present. In another eight patients, the predominant lesion was found to be mitral stenosis rather than mitral insufficiency as it was thought to be before catheterization. In two patients, who had only systolic murmurs, catheterization revealed mitral stenosis rather than mitral insufficiency. In four patients who were thought to have mixed valvular disease, left heart catheterization showed only aortic valvular disease.  相似文献   

7.
Gerbode defect is a rare type of left ventricle to right atrium shunt. It is usually congenital in origin, but acquired cases are also described, mainly following infective endocarditis, valve replacement, trauma or acute myocardial infarction. We report a case of a 50-year-old man who suffered an extensive and complex infective endocarditis involving a bicuspid aortic valve, the mitral-aortic intervalvular fibrosa and the anterior leaflet of the mitral valve. After dual valve replacement and annular reconstruction, a shunt between the left ventricle and the right atrium - Gerbode defect, and a severe leak of the mitral prosthesis were detected. Reintervention was performed with successful shunt closure with an autologous pericardial patch and paravalvular leak correction. No major complications occurred denying the immediate post-surgery period and the follow-up at the first year was uneventful.  相似文献   

8.
Perforation of the left main stem is a rare complication associated with combined aortic valve replacement and by-pass surgery. One-year following aortic valve replacement a 70-year-old male presented with chest pain. This was related to a slowly expanding haematoma caused by a low profile chronic perforation of the left main. Subsequently, a tailored percutaneous modification of the main stem was performed. At three months follow-up, he had no complaints and selective coronary angiography confirmed the successful sealing of the perforation with a concomitant regression of the prior haematoma.  相似文献   

9.
In this case report, we present the use of intracardiac echocardiography (ICE) for guiding the cardiac catheterization and subsequent hemodynamic investigation in an unusual patient case with multiple congenital abnormalities (bicuspid aortic valve, left cervical aortic arch, two aortic coarctations) and two aortic valve replacement operations in the past. The ICE catheter (AcuNav) permitted us to accurately and safely puncture the interatrial septum and place the Swan-Ganz catheter in the left ventricle; additionally, visualization of the aortic coarctation in the ascending aorta was also achieved.  相似文献   

10.
Doris Kavanagh-Gray 《CMAJ》1966,95(8):354-356
One hundred consecutive aortograms, performed with careful attention to recommended technical details, were reviewed to identify cases of “factitious” aortic valve insufficiency, viz. aortic regurgitation seen during aortography for which there is no clinical evidence. Five patients with this condition were identified. Two of these subsequently underwent mitral valve replacement under cardiopulmonary by-pass. Aortic insufficiency was not detected during this procedure and the aortic valve appeared to be anatomically normal at postmortem examination. That factitious aortic insufficiency may exist should be remembered when aortography is used to differentiate aortic from pulmonary valve insufficiency.  相似文献   

11.
Doris Kavanagh-Gray 《CMAJ》1965,93(19):1009-1014
Criteria for selection of patients with aortic valve disease for cardiac catheterization are described, based on a study of 81 cases. Children with aortic stenosis warrant catheterization at the time when the clinical diagnosis is made, but in adults this examination may be deferred until symptoms appear or left ventricular hypertrophy is recognized. In patients with pure aortic insufficiency catheterization may be deferred until symptoms appear. When severe stenosis and insufficiency co-exist, the valve is usually heavily calcified. Thirty-seven per cent of patients with aortic valve disease have co-existing mitral lesions and these patients are usually women, are fibrillating and, as a rule, have atrial enlargement in contrast to those with aortic valve disease only. On rare occasions, patients with mitral valve disease have clinically silent but angiographically demonstrable aortic insufficiency; therefore, aortography should precede open-heart correction of a mitral lesion so as to detect minor degrees of aortic insufficiency.  相似文献   

12.
Follow-up studies on 132 patients who have received fresh aortic homograft replacement of the mitral valve since May 1967 indicate good long-term function of the valve. Clinically the majority of patients are greatly improved and are free from the risks of long-term anticoagulant therapy. Hemodynamic studies performed on 13 patients at 25 to 41 months postoperatively showed a significant decrease in left atrial and pulmonary artery pressures with a small increase in cardiac output. Late deterioration of the homograft produced severe insufficiency in four cases and organic stenosis in two cases. Reasons for isolated deterioration are suggested.  相似文献   

13.
21毫米人造心脏瓣膜泵的设计及研制   总被引:1,自引:0,他引:1  
为了研究能够长期置入主动脉瓣环的左心室辅助装置,研制出直径21毫米重27克可植入的主动脉瓣膜泵.装置包括一个转子和一个定子.转子由驱动磁钢和叶轮组成;定子装有带铁心的电机线圈和出口导叶.装置被置於主动脉瓣位置,所以不占用额外的解剖空间.血泵能像自然心脏一样直接将血液由心室输送到主动脉,不需要连接管道和旁路,因此对自然生理循环的干扰可以减到最低.血泵流量由最大到零周期变化.血液动力学测试表明,当血泵转速为17500转/分钟时,可以产生流量5升/分钟、压力增益50毫米汞柱的血流;同一转速下,当流量为零时,血泵能保持主动脉舒张压为80毫米汞柱.  相似文献   

14.
Angiotensin converting enzyme (ACE) inhibition has been reported to induce regression of hypertrophy in several models of hemodynamic pressure overload. The aim of the present study was to determine whether the ACE inhibitor captopril can reduce hypertrophy of the left ventricle induced by a chronic volume overload and modify collagen composition of the hypertrophied myocardium. Rabbits with four months lasting aortic insufficiency were divided into two groups: treated with captopril (20 mg/kg/day) for five weeks and treated with placebo. The respective control groups were represented by sham-operated animals. Aortic insufficiency induced a decrease of diastolic pressure, an increase of systolic and pulse pressure, hypertrophy of the left and right ventricle, and an increase of hydroxyproline content in the left ventricle without a change of hydroxyproline concentrations in either ventricle. Captopril treatment further enhanced pulse pressure by decreasing diastolic blood pressure. Hypertrophy of the left ventricle, hydroxyproline content and concentration in both ventricles were unaffected by captopril treatment. It is concluded that ACE inhibition did not reverse the left ventricular hypertrophy developed as a result of overload induced by aortic insufficiency. We suggest that mechanisms different from activation of the renin-angiotensin system may play a decisive role in the maintenance of hypertrophy in this particular model of volume hemodynamic overload.  相似文献   

15.
In trying to assess the benefit of cardiac surgery in AIDS patients, the question arises whether a patient with a deficient immune system can tolerate open heart surgery well enough to make the operation worthwhile. Surgical procedures and cardiopulmonary bypass have been noted to alter immune function (Diettrich et al., Ide et al.). Therefore, the presence of clinical AIDS is often still regarded as a contraindication to cardiac surgery. In this report we describe an AIDS patient who developed endocarditis of the native aortic valve. The endocarditis was successfully treated with antibiotic drugs, but the patient was left with damaged valves. Over the months he developed a massive aortic insufficiency and underwent aortic valve replacement. The patient did well after surgery, and is alive and well 18 months after the operation, suggesting that cardiac surgery might be a good and valuable treatment option in AIDS patients.  相似文献   

16.
John C. Callaghan 《CMAJ》1964,91(9):411-421
The aortic and mitral valves were replaced in 50 patients at the University of Alberta Hospital using the Starr-Edwards ball-valve prosthesis. The basis of the selection of 20 patients for isolated aortic valve replacement and 27 for mitral valve replacement using this type of prosthesis is presented, and the techniques of insertion of the aortic and mitral valve are described in detail. Of the 27 patients in whom the mitral valve was replaced by the Starr-Edwards prosthesis six died within 30 days of surgery and two after discharge from hospital at two and a half and four months, respectively. Left atrial thrombosis was the cause of death in four of these patients. In 20 patients in whom the aortic valve was replaced, four died in hospital and two died more than 30 days after returning home. Three of these six patients died from bleeding—the result of the use of anticoagulants. The difficulty in assessing whether or not anticoagulants are needed following replacement by a Starr-Edwards prosthesis is considered. It is felt, in our present state of knowledge, that anticoagulants should be used following mitral valve replacement but are probably not essential following replacement of the aortic valve. Two patients survived replacement of both aortic and mitral valves and have been followed up 18 months and seven months, respectively.  相似文献   

17.
Transapical aortic valve implantation requires puncture of the left ventricle apex and insertion of a 32-French delivery sheath. A critical step in the procedure consists of secure closure of the ventricular apex. We describe 2 cases of apical rupture of 42 transapical aortic valve implantations. Furthermore, we describe the use of a newly designed single circular Teflon pledget that can help to avoid this complication. This pledget provides a more secure and uniform shrinkage of the entire apex to close the defect left by the delivery sheath.  相似文献   

18.
It has been reported that 30-40% of patients with aortic stenosis are hypertensive. In such patients, the left ventricle faces a double (i.e. valvular and vascular) pressure overload, which results in subsequent wall volume hypertrophy. From a clinical standpoint, it is difficult to separate the respective contributions of aortic stenosis and systemic hypertension to left ventricular burden and patient's symptoms and thus to predict whether valve replacement would be beneficial. The objective of this theoretical study was therefore to investigate the relative effects of valvular and vascular afterloads on left ventricular hypertrophy. We used a ventricular-valvular-vascular mathematical model in combination with the Arts' model describing the myofiber stress. Left ventricular wall volume was computed for different aortic blood pressure levels and different degrees of aortic stenosis severity. Our simulations show that the presence of concomitant systemic hypertension has a major influence on the development of left ventricular hypertrophy in patients with aortic stenosis. These results also suggest that mild-to-moderate aortic stenosis has a minor impact on left ventricular wall volume when compared with hypertension. On the other hand, when aortic stenosis is severe, wall volume increases exponentially with increasing aortic stenosis severity and the impact of aortic stenosis on left ventricular hypertrophy becomes highly significant.  相似文献   

19.
K. S. Baichwal  Arthur M. Vineberg 《CMAJ》1964,91(25):1294-1299
Thirty patients with mitral valve disease operated upon by the open-heart technique during the period 1958-1962 were studied. In 15 insufficiency predominated. Clinical, radiological and pathological findings included the following: aortic valve disease is the commonest associated lesion; cusp calcification is uncommon in mitral insufficiency; left atrial enlargement is more pronounced in mitral insufficiency; a relaxed annulus is the commonest pathological lesion associated with mitral insufficiency, with ruptured chordae in second place. Five of the 15 patients with mitral insufficiency and four of the 15 with mitral stenosis died during the postoperative period, while clinical improvement was apparent in seven and 11, in the respective groups. The standard techniques of annuloplasty, suturing of ruptured chordae, and open commissurotomy were found to provide satisfactory results. Partial Ivalon prosthetic replacement was unsatisfactory. The study suggests that a more liberal use of the open-heart procedure in surgical correction of complicated mitral valve lesions is indicated.  相似文献   

20.

Background

Transcatheter aortic valve replacement is indicated for severe symptomatic aortic stenosis in patients who have a very high or prohibitive surgical risk as assessed pre-procedurally by the Society of Thoracic Surgery Risk Score, EuroSCORE (II), frailty testing, and other predictors. When combined with another left ventricular outflow tract obstruction, careful consideration must be taken prior to proceeding with transcatheter aortic valve replacement because an additional masked left ventricular outflow tract pathology can lead to challenging hemodynamics in the peri-deployment phase, as reported in this case.

Case presentation

A 56-year-old Caucasian man with multiple comorbidities and severe aortic stenosis underwent transcatheter aortic valve replacement under monitored anesthesia care. During the deployment phase, he developed dyspnea that progressed to pulmonary edema requiring emergent conversion to general anesthesia, orotracheal intubation, acute respiratory distress syndrome-type ventilation, and vasopressor medications. Intraoperative transesophageal echocardiography was performed and hypertrophic obstructive cardiomyopathy with systolic anterior motion of the mitral valve was discovered as an underlying pathology, undetected on preoperative imaging. After treatment with beta blockers, fluid resuscitation, and alpha-1 agonists, he stabilized and was eventually discharged from our hospital without any lasting sequelae.

Conclusions

Patients with aortic stenosis most often develop symmetric hypertrophy; however, a small subset has asymmetric septal hypertrophy leading to left ventricular outflow tract obstruction. In cases of severe aortic stenosis, however, evidence of left ventricular outflow tract obstruction via both symptoms and echocardiographic findings may be minimized due to extremely high afterload on the left ventricle. Diagnosing a left ventricular outflow tract obstruction as the cause of hemodynamic instability during transcatheter aortic valve replacement, in the absence of abnormal findings on echocardiogram preoperatively, requires a high index of clinical suspicion. The management of acute onset left ventricular outflow tract obstruction intraoperatively consists primarily of medical therapy, including rate control, adequate volume resuscitation, and avoidance of inotropes. With persistently elevated gradients, interventional treatments may be considered.
  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号