首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
International bodies such as International Commission on Non-Ionizing Radiation Protection (ICNIRP) and the Institute for Electrical and Electronic Engineering (IEEE) make provision for human exposure assessment based on SAR calculations (or measurements) and basic restrictions. In the case of base station exposure this is mostly applicable to occupational exposure scenarios in the very near field of these antennas where the conservative reference level criteria could be unnecessarily restrictive. This study presents a variety of critical aspects that need to be considered when calculating SAR in a human body close to a mobile phone base station antenna. A hybrid FEM/MoM technique is proposed as a suitable numerical method to obtain accurate results. The verification of the FEM/MoM implementation has been presented in a previous publication; the focus of this study is an investigation into the detail that must be included in a numerical model of the antenna, to accurately represent the real-world scenario. This is accomplished by comparing numerical results to measurements for a generic GSM base station antenna and appropriate, representative canonical and human phantoms. The results show that it is critical to take the disturbance effect of the human phantom (a large conductive body) on the base station antenna into account when the antenna-phantom spacing is less than 300 mm. For these small spacings, the antenna structure must be modeled in detail. The conclusion is that it is feasible to calculate, using the proposed techniques and methodology, accurate occupational compliance zones around base station antennas based on a SAR profile and basic restriction guidelines.  相似文献   

2.
This paper investigates the minimum distance for a human body in the near field of a cellular telephone base station antenna for which there is compliance with the IEEE or ICNIRP threshold values for radio frequency electromagnetic energy absorption in the human body. First, local maximum specific absorption rates (SARs), measured and averaged over volumes equivalent to 1 and to 10 g tissue within the trunk region of a physical, liquid filled shell phantom facing and irradiated by a typical GSM 900 base station antenna, were compared to corresponding calculated SAR values. The calculation used a homogeneous Visible Human body model in front of a simulated base station antenna of the same type. Both real and simulated base station antennas operated at 935 MHz. Antenna-body distances were between 1 and 65 cm. The agreement between measurements and calculations was excellent. This gave confidence in the subsequent calculated SAR values for the heterogeneous Visible Human model, for which each tissue was assigned the currently accepted values for permittivity and conductivity at 935 MHz. Calculated SAR values within the trunk of the body were found to be about double those for the homogeneous case. When the IEEE standard and the ICNIRP guidelines are both to be complied with, the local SAR averaged over 1 g tissue was found to be the determining parameter. Emitted power values from the antenna that produced the maximum SAR value over 1 g specified in the IEEE standard at the base station are less than those needed to reach the ICNIRP threshold specified for the local SAR averaged over 10 g. For the GSM base station antenna investigated here operating at 935 MHz with 40 W emitted power, the model indicates that the human body should not be closer to the antenna than 18 cm for controlled environment exposure, or about 95 cm for uncontrolled environment exposure. These safe distance limits are for SARs averaged over 1 g tissue. The corresponding safety distance limits under the ICNIRP guidelines for SAR taken over 10 g tissue are 5 cm for occupational exposure and about 75 cm for general-public exposure.  相似文献   

3.
In this article, the exposure to radio frequency electromagnetic fields was studied in close proximity (distances of 10, 100, 300, and 600 mm) to six base station antennas. The specific absorption rate (SAR) in 800 mm × 500 mm × 200 mm box phantom as well as unperturbed electric field (E) in air was measured. The results were used to determine whether the measurement of local maximum of unperturbed electric field can be used as a compliance check for local exposure. Also, the conservativeness of this assessment method compared to the ICNIRP basic restriction was studied. Moreover, the assessment of whole‐body exposure was discussed and the distance ranges presented in which the ICNIRP limit for local exposure could be exceeded before the limit for whole‐body SAR. These results show that the electric field measurement alone can be used for easy compliance check for the local exposure at all distances and for all antenna types studied. However, in some cases when the local peak value of E was compared directly to the ICNIRP reference level for unperturbed E, the exposure was overestimated only very slightly (by factor 1.1) compared to the basic restriction for localized SAR in a human, and hence these results can not be generalized to all antenna types. Moreover, it was shown that the limit for localized exposure could be exceeded before the limit for the whole‐body average SAR, if the distance to the antenna was less than 240 mm. Bioelectromagnetics 30:307–312, 2009. © 2009 Wiley‐Liss, Inc.  相似文献   

4.
Bahr A  Dorn H  Bolz T 《Bioelectromagnetics》2006,27(4):320-327
An exposure system for investigation of volunteers during simulated GSM and WCDMA mobile phone usage has been designed. The apparatus consists of a dual band antenna with enhanced carrying properties that enables exposure for at least 8 h a day. For GSM a 900 MHz pulse modulated carrier was used. The QPSK modulated WCDMA signal at 1966 MHz comprises a power control scheme, which was designed for investigations of biological effects. The dosimetry of the exposure system by measurements and calculations is described in detail within this paper. It is shown that the SAR distribution of the antenna shows similar characteristics to mobile phones with an integrated antenna. The 10 g averaged localized SAR, normalized to an antenna input power of 1 W and measured in the flat phantom area of the SAM phantom, amounts to 7.82 mW/g (900 MHz) and 10.98 mW/g (1966 MHz). The simulated SAR(10 g) in the Visible Human head model agrees with measured values to within 20%. A variation of the antenna rotation angle results in an SAR(10 g) change below 17%. The increase of the antenna distance by 2 mm with respect to the human head leads to an SAR(10 g) change of 9%.  相似文献   

5.
Localized and averaged specific absorption rates (SARs) were obtained in a full-size muscle-equivalent human model exposed to near-field 29.9 MHz irradiation at an outdoor facility. The model was positioned erect on a metallic groundplane 1.22 m (4 ft) from the base of a 10.8-m (35 ft) whip antenna with an input power of 1.0 kW. For whole-body SAR, a mean value of 0.83 W/kg was determined using two gradient-layer calorimeters in a twin-well configuration. The localized SARs at 12 body locations were measured using nonperturbing temperature probes and were highest in the ankle region. We conclude that averaged SAR measurements in a full-size phantom are feasible using a twin-calorimeter approach; measurements in the field are practical when human-size (183 x 61 x 46 cm) calorimeters are used.  相似文献   

6.
A new human head phantom has been proposed by CENELEC/IEEE, based on a large scale anthropometric survey. This phantom is compared to a homogeneous Generic Head Phantom and three high resolution anatomical head models with respect to specific absorption rate (SAR) assessment. The head phantoms are exposed to the radiation of a generic mobile phone (GMP) with different antenna types and a commercial mobile phone. The phones are placed in the standardized testing positions and operate at 900 and 1800 MHz. The average peak SAR is evaluated using both experimental (DASY3 near field scanner) and numerical (FDTD simulations) techniques. The numerical and experimental results compare well and confirm that the applied SAR assessment methods constitute a conservative approach.  相似文献   

7.
This article describes three microwave catheter antennas for percutaneous cardiac ablation. A particular design feature of these antennas is that there is no reflected microwave current from the antenna flowing up the transmission line. Thus, it minimizes heating of the coaxial cable. The power reflection coefficients are very low (4% or less) in phantom equivalent materials. These antennas can also serve as bipolar electrodes for sensing endocardiac electrograms. Our studies in dogs, during both cardiopulmonary bypass and closed‐chest operations via the femoral vein, have shown microwave energy greater than 200 joules (J) delivered to the heart through a split‐tip dipole catheter antenna can produce irreversible block of the heart rhythms. This energy was achieved either by increasing the delivered power from 20 to 40 watts or by increasing the treatment duration from 7 to 11 s (210 to 330 J per application). It produced an endocardium temperature of about 65 ºC. We found that the percutaneous, transcatheter microwave system is capable of inducing AV blocks consistently in dogs using the flexible, curved tip, split‐tip catheter antenna. In addition, our studies have shown that the width and height of SAR distributions for cap‐choke and split‐tip catheter antennas are similar for the same antenna length. The cap‐slot design had a much longer SAR distribution compared to the others. Moreover, a longer (4 mm) split‐tip antenna can also induce larger lesions. These results suggest that it could be possible to ablate a ventricular tachycardia focus using the 4 mm split‐tip as well as the cap‐slot microwave catheter antennas. Bioelectromagnetics 20:120–132, 1999. © 1999 Wiley‐Liss, Inc.  相似文献   

8.
This study investigates occupational exposure to electromagnetic fields in front of a multi‐band base station antenna for mobile communications at 900, 1800, and 2100 MHz. Finite‐difference time‐domain method was used to first validate the antenna model against measurement results published in the literature and then investigate the specific absorption rate (SAR) in two heterogeneous, anatomically correct human models (Virtual Family male and female) at distances from 10 to 1000 mm. Special attention was given to simultaneous exposure to fields of three different frequencies, their interaction and the additivity of SAR resulting from each frequency. The results show that the highest frequency—2100 MHz—results in the highest spatial‐peak SAR averaged over 10 g of tissue, while the whole‐body SAR is similar at all three frequencies. At distances >200 mm from the antenna, the whole‐body SAR is a more limiting factor for compliance to exposure guidelines, while at shorter distances the spatial‐peak SAR may be more limiting. For the evaluation of combined exposure, a simple summation of spatial‐peak SAR maxima at each frequency gives a good estimation for combined exposure, which was also found to depend on the distribution of transmitting power between the different frequency bands. Bioelectromagnetics 32:234–242, 2011. © 2010 Wiley‐Liss, Inc.  相似文献   

9.
This study reports the dosimetry performed to support an experiment that measured physiological responses of volunteer human subjects exposed to the resonant frequency for a seated human adult at 100 MHz. Exposures were performed in an anechoic chamber which was designed to provide uniform fields for frequencies of 100 MHz or greater. A half wave dipole with a 90 degrees reflector was used to optimize the field at the subject location. The dosimetry plan required measurement of transmitter harmonics, stationary probe drift, field strengths as a function of distance, electric and magnetic field maps at 200, 225, and 250 cm from the dipole antenna, and specific absorption rate (SAR) measurements using a human phantom, as well as theoretical predictions of SAR with the finite difference time domain (FDTD) method. On each exposure test day, a measurement was taken at 225 cm on the beam centerline with a NBS E field probe to assure consistently precise exposures. A NBS 10 cm loop antenna was positioned 150 cm to the right, 100 cm above, and 60 cm behind the subject and was read at 5 min intervals during all RF exposures. These dosimetry measurements assured accurate and consistent exposures. FDTD calculations were used to determine SAR distribution in a seated human subject. This study reports the necessary dosimetry for work on physiological consequences of human volunteer exposures to 100 MHz.  相似文献   

10.
The so-called carousel setup has been widely utilized for testing the hypotheses of adverse health effects on the central nervous system (CNS) due to mobile phone exposures in the frequency bands 800-900 MHz. The objectives of this article were to analyze the suitability of the setup for the upper mobile frequency range, i.e., 1.4-2 GHz, and to conduct a detailed experimental and numerical dosimetry for the setup at the IRIDIUM frequency band of 1.62 GHz. The setup consists of a plastic base on which ten rats, restrained in radially positioned tubes, are exposed to the electromagnetic field emanating from a sleeved dipole antenna at the center. Latest generation miniaturized dosimetric E field and temperature probes were used to measure the specific absorption rate (SAR) inside the brain of three rat cadavers of the Lewis strain and two rat cadavers of the Fisher 344 strain. A numerical analysis was conducted on the basis of three numerical rat phantoms with voxel sizes between 1.5 and 0.125 mm3 that are based on high resolution MRI scans of a 300 g male Wistar rat and a 370 g male Sprague-Dawley rat. The average of the assessed SAR values in the brain was 2.8 mW/g per W antenna input power for adult rats with masses between 220 and 350 g and 5.3 mW/g per W antenna input power for a juvenile rat with a mass of 95 g. The strong increase of the SAR in the brain with decreasing animal size was verified by simulations of the absorption in numerical phantoms scaled to sizes between 100 and 500 g with three different scaling methods. The study also demonstrated that current rat phantom models do not provide sufficient spatial resolution to perform absolute SAR assessment for the brain tissue. The variation of the SAR(brain)(av) due to changes in position was assessed to be in the range from +15% to -30%. A study on the dependence of the performance of the carousel setup on the frequency revealed that efficiency, defined as SAR(brain)(av) per W antenna input power, and the ratio between SAR(brain)(av) and SAR(body)(av) are optimal in the mobile communications frequency range, i.e., 0.8-3 GHz.  相似文献   

11.
This study reports the dosimetry performed to support an experiment that measured physiological responses of seated volunteer human subjects exposed to 220 MHz fields. Exposures were performed in an anechoic chamber which was designed to provide uniform fields for frequencies of 100 MHz or greater. A vertical half-wave dipole with a 90 degrees reflector was used to optimize the field at the subject's location. The vertically polarized E field was incident on the dorsal side of the phantoms and human volunteers. The dosimetry plan required measurement of stationary probe drift, field strengths as a function of distance, electric and magnetic field maps at 200, 225, and 250 cm from the dipole antenna, and specific absorption rate (SAR) measurements using a human phantom, as well as theoretical predictions of SAR with the finite difference time domain (FDTD) method. A NBS (National Bureau of Standards, now NIST, National Institute of Standards and Technology, Boulder, CO) 10 cm loop antenna was positioned 150 cm to the right, 100 cm above and 60 cm behind the subject (toward the transmitting antenna) and was read prior to each subject's exposure and at 5 min intervals during all RF exposures. Transmitter stability was determined by measuring plate voltage, plate current, screen voltage and grid voltage for the driver and final amplifiers before and at 5 min intervals throughout the RF exposures. These dosimetry measurements assured accurate and consistent exposures. FDTD calculations were used to determine SAR distribution in a seated human subject. This study reports the necessary dosimetry to precisely control exposure levels for studies of the physiological consequences of human volunteer exposures to 220 MHz.  相似文献   

12.
Energy deposition in a model of man in the near field   总被引:3,自引:0,他引:3  
The spatial distribution of the specific absorption rate (SAR) was measured in a full-scale model of man using implantable electric field probes. The model was exposed in the near-field of linear and aperture antennas at 350 MHz. Effects of the wave polarization, antenna position and antenna gain on the SAR distribution and the average SAR in the whole-body and body parts are reported.  相似文献   

13.
Implantable neural interfaces are designed to provide a high spatial and temporal precision control signal implementing high degree of freedom real-time prosthetic systems. The development of a Radio Frequency (RF) wireless neural interface has the potential to expand the number of applications as well as extend the robustness and longevity compared to wired neural interfaces. However, it is well known that RF signal is absorbed by the body and can result in tissue heating. In this work, numerical studies with analytical validations are performed to provide an assessment of power, heating and specific absorption rate (SAR) associated with the wireless RF transmitting within the human head. The receiving antenna on the neural interface is designed with different geometries and modeled at a range of implanted depths within the brain in order to estimate the maximum receiving power without violating SAR and tissue temperature elevation safety regulations. Based on the size of the designed antenna, sets of frequencies between 1 GHz to 4 GHz have been investigated. As expected the simulations demonstrate that longer receiving antennas (dipole) and lower working frequencies result in greater power availability prior to violating SAR regulations. For a 15 mm dipole antenna operating at 1.24 GHz on the surface of the brain, 730 uW of power could be harvested at the Federal Communications Commission (FCC) SAR violation limit. At approximately 5 cm inside the head, this same antenna would receive 190 uW of power prior to violating SAR regulations. Finally, the 3-D bio-heat simulation results show that for all evaluated antennas and frequency combinations we reach FCC SAR limits well before 1 °C. It is clear that powering neural interfaces via RF is possible, but ultra-low power circuit designs combined with advanced simulation will be required to develop a functional antenna that meets all system requirements.  相似文献   

14.
Human exposure to electromagnetic fields produced by two wearable antennas operating in the 2.4 GHz frequency band was assessed by computational tools. Both antennas were designed to be attached to the skin, but they were intended for different applications. The first antenna was designed for off-body applications, i.e. to communicate with a device placed outside the body, while the second antenna model was optimized to communicate with a device located inside the body. The power absorption in human tissues was determined at several locations of adult male and female body models. The maximum specific absorption rate (SAR) value obtained with the off-body antenna was found on the torso of the woman model and was equal to 0.037 W/kg at 2.45 GHz. SAR levels increased significantly for the antenna transmitting inside the body. In this case, SAR values ranged between 0.23 and 0.45 W/kg at the same body location. The power absorbed in different body tissues and total power absorbed in the body were also calculated; the maximum total power absorbed was equal to 5.2 mW for an antenna input power equal to 10 mW. Bioelectromagnetics. 2020;41:73–79 © 2019 Wiley Periodicals, Inc.  相似文献   

15.
Electric fields (E-fields) induced within a phantom head from exposure to three different advanced mobile phone system (AMPS) hand-held telephones were measured using an implantable E-field probe. Measurements were taken in the eye nearest the phone and along a lateral scan through the brain from its centre to the side nearest the phone. During measurement, the phones were positioned alongside the phantom head as in typical use and were configured to transmit at maximum power (600 mW nominal). The specific absorption rate (SAR) was calculated from the in situ E-field measurements, which varied significantly between phone models and antenna configuration. The SARs induced in the eye ranged from 0.007 to 0.21 W/kg. Metal-framed spectacles enhanced SAR levels in the eye by 9–29%. In the brain, maximum levels were recorded at the measurement point closest to the phone and ranged from 0.12 to 0.83 W/kg. These SARs are below peak spatial limits recommended in the U.S. and Australian national standards [IEEE Standards Coordinating Committee 28 (1991): C95.1-1991 and Standards Australia (1990): AS2772.1-1990] and the IRPA guidelines for safe exposure to radio frequency (RF) electromagnetic fields [IRPA (1988): Health Phys 54:115–123]. Furthermore, a detailed thermal analysis of the eye indicated only a 0.022°C maximum steady-state temperature rise in the eye from a uniform SAR loading of 0.21 W/kg. A more approximate thermal analysis in the brain also indicated only a small maximum temperature rise of 0.034°C for a local SAR loading of 0.83 W/kg. © 1995 Wiley-Liss, Inc.  相似文献   

16.
Cancers of the neck, breast, and lower extremities are common malignancies diagnosed in India with a higher incidence of advanced-stage disease. Phased array (PA) applicators reported for hyperthermia treatment (HT) of the breast have small focal region and high cross-coupling, and those reported for lower extremities provide regional heating and limited steering. In this study, we present the numerical design of site-specific PA applicators for HT of large solid tumors in the neck, breast, and lower extremities using a miniaturized 434 MHz cavity-backed water-loaded patch antenna. The fabricated antenna has 38 × 36 mm2 aperture, more than 90% power coupling, 25 MHz bandwidth, and good agreement between simulated and measured specific absorption rate (SAR) in phantom. The site-specific applicators demonstrated less power reflection (<−17.9 dB) and cross-coupling (<−26.8 dB) for 5 mm inter-ring spacing. SAR indicators for 64 cc tumor at varying locations in simplified layered three-dimensional (3D) tissue models of the neck, breast, and leg showed average power absorption ratio (aPAratio) ≥ 3.16, target to hotspot quotient (THQ) ≥ 0.57, 25% iso-SAR coverage (TC25) ≥ 81%, and 50% iso-SAR coverage (TC50) ≥51.8%. Simulation results of site-specific applicators for 3D inhomogeneous patient models showed aPAratio ≥ 5.98, THQ ≥ 0.9, TC50 ≥ 86%, and 100% TC25 for all sites. It is concluded that the 434 MHz miniaturized cavity-backed patch antenna can be used to develop high-density PA applicators with 12–24 antennas for HT of large solid tumors (≥4 cm) in the neck, breast, and lower extremities with 3D steering ability and less cross-coupling (≤−26.8 dB). © 2020 Bioelectromagnetics Society  相似文献   

17.
A dual-band microstrip antenna operating at GSM 900 and GSM 1800 MHz is designed initially. Then a single split ring resonator (SRR) structure is used as a superstrate for this dual-band antenna. A circular current is induced in the SRR due to the perpendicular plane wave excitation, which in turn leads to an electric excitation coupled to the magnetic resonance. It also exhibits higher order excitations at 0.9 and 1.8 GHz which ultimately resulted in specific absorption rate (SAR) reduction of human head at both the designed frequencies of the antenna. The antenna and the SRR superstrate are printed on a 1.6 mm thick FR-4 substrate of dimension 59.6 × 49.6 mm2. Analysis of the SRR using the classic waveguide theory approach is discussed. Radiation pattern of the antenna in the presence of SRR superstrate and human head is also discussed. Prototype of the antenna along with the SRR superstrate is fabricated and measured for return loss and radiation pattern. Measurement results fairly agree with the simulated results. A human head phantom is utilized in the calculation of SAR.  相似文献   

18.
Implantable Brain Computer Interfaces (BCIs) are designed to provide real-time control signals for prosthetic devices, study brain function, and/or restore sensory information lost as a result of injury or disease. Using Radio Frequency (RF) to wirelessly power a BCI could widely extend the number of applications and increase chronic in-vivo viability. However, due to the limited size and the electromagnetic loss of human brain tissues, implanted miniaturized antennas suffer low radiation efficiency. This work presents simulations, analysis and designs of implanted antennas for a wireless implantable RF-powered brain computer interface application. The results show that thin (on the order of 100 micrometers thickness) biocompatible insulating layers can significantly impact the antenna performance. The proper selection of the dielectric properties of the biocompatible insulating layers and the implantation position inside human brain tissues can facilitate efficient RF power reception by the implanted antenna. While the results show that the effects of the human head shape on implanted antenna performance is somewhat negligible, the constitutive properties of the brain tissues surrounding the implanted antenna can significantly impact the electrical characteristics (input impedance, and operational frequency) of the implanted antenna. Three miniaturized antenna designs are simulated and demonstrate that maximum RF power of up to 1.8 milli-Watts can be received at 2 GHz when the antenna implanted around the dura, without violating the Specific Absorption Rate (SAR) limits.  相似文献   

19.
The three‐dimensional distribution of the specific absorption rate of energy (SAR) in phantom models was analysed to detect clusters of mobile phones producing similar spatial deposition of energy in the head. The clusters' characteristics were described from the phones external features, frequency band and communication protocol. Compliance measurements with phones in cheek and tilt positions, and on the left and right side of a physical phantom were used. Phones used the Personal Digital Cellular (PDC), Code division multiple access One (CdmaOne), Global System for Mobile Communications (GSM) and Nordic Mobile Telephony (NMT) communication systems, in the 800, 900, 1500 and 1800 MHz bands. Each phone's measurements were summarised by the half‐ellipsoid in which the SAR values were above half the maximum value. Cluster analysis used the Partitioning Around Medoids algorithm. The dissimilarity measure was based on the overlap of the ellipsoids, and the Manhattan distance was used for robustness analysis. Within the 800 MHz frequency band, and in part within the 900 MHz and the 1800 MHz frequency bands, weak clustering was obtained for the handset shape (bar phone, flip with top and flip with central antennas), but only in specific positions (tilt or cheek). On measurements of 120 phones, the three‐dimensional distribution of SAR in phantom models did not appear to be related to particular external phone characteristics or measurement characteristics, which could be used for refining the assessment of exposure to radiofrequency energy within the brain in epidemiological studies such as the Interphone. Bioelectromagnetics. Bioelectromagnetics 32:634–643, 2011. © 2011 Wiley Periodicals, Inc.  相似文献   

20.
A metamaterial-embedded planar inverted-F antenna (PIFA) is proposed in this study for cellular phone applications. A dual-band PIFA is designed to operate both GSM 900 MHz and DCS 1800 MHz. The ground plane of a conventional PIFA is modified using a planar one-dimensional metamaterial array. The investigation is performed using the Finite Integration Technique (FIT) of CST Microwave Studio. The performance of the developed antenna was measured in an anechoic chamber. The specific absorption rate (SAR) values are calculated considering two different holding positions: cheek and tilt. The SAR values are measured using COMOSAR measurement system. Good agreement is observed between the simulated and measured data. The results indicate that the proposed metamaterial-embedded antenna produces significantly lower SAR in the human head compared to the conventional PIFA. Moreover, the modified antenna substrate leads to slight improvement of the antenna performances.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号