1.
2.
A high-performance liquid chromatographic method for the determination of picotamide in human plasma and urine is described. After addition of an internal standard (bamifylline), the plasma and urine samples were subjected to liquid—liquid extraction and clean-up procedures. The final extracts were evaporated to dryness and the resulting residues were reconstituted in 100 μl of methanol—water (50:50, v/v) and chromatographed on a LiChrosorb RP-SELECT B reversed-phase column coupled to an ultraviolet detector monitored at 230 nm. Chromatographic analysis takes about 10 min per sample. The assay was linear over a wide range and has a limit of detection of 0.005 and 0.1 μg/ml in plasma and urine, respectively. It was selective for picotamide, accurate and robust and thus suitable for routine assays after therapeutic doses of picotamide.  相似文献   

3.
An improved, rapid and specific high-performance liquid chromatographic assay was developed for the determination of famotidine in human plasma and urine. Plasma samples were alkalinized and the analyte and internal standard (cimetidine) extracted with water-saturated ethyl acetate. The extracts were reconstituted in mobile phase, and injected onto a C18 reversed-phase column; UV detection was set at 267 nm. Urine samples were diluted with nine volumes of a mobile phase-internal standard mixture prior to injection. The lower limits of quantification in plasma and urine were 75 ng/ml and 1.0 μg/ml, respectively; intra- and inter-day coefficients of variation were ≤10.5%. This method is currently being used to support renal function studies assessing the use of intravenously administered famotidine to characterize cationic tubular secretion in man.  相似文献   

4.
Simultaneous determination of mycophenolic acid (MPA) and mycophenolate phenol glucuronide (MPAG) in plasma and urine was accomplished by isocratic HPLC with UV detection. Plasma was simply deproteinated with acetonitrile and concentrated, whereas urine was diluted prior to analysis. Linearity was observed from 0.2 to 50 μg/ml for both MPA and MPAG in plasma and from 1 to 50 μg/ml of MPA and 5 to 2000 μg/ml MPAG in urine with extraction recovery from plasma greater than 70%. Detection limits using 0.25 ml plasma were 0.080 and 0.20 μg/ml for MPA and MPAG, respectively. The method is more rapid and simple than previous assays for MPA and MPAG in biological fluids from patients.  相似文献   

5.
Enantiomers of metoprolol and its acidic metabolite H 117/04 were determined in human urine by high-performance liquid chromatography (HPLC) with fluorometric detection after chiral derivatization. The carboxyl functional group of the major metabolite was blocked by esterification after solid-phase extraction, which helped to quantitate this compound from interfering substances. The assay method was validated. The recovery of (−)- and (+)-metoprolol from urine was 86.3–90.5%; and the recovery of the (−)- and (+)-acidic metabolite H 117/04 from urine was 74.4–83.9% at different concentrations.  相似文献   

6.
A rapid, sensitive and specific high-performance liquid chromatographic (HPLC) assay was developed for the determination of amdinocillin (formerly mecillinam) in human plasma and urine. The assay is performed by direct injection of a plasma protein-free supernatant or a dilution of urine. A 10-μm μBondapak phenyl column with an eluting solvent of water—methanol—1 M phosphate buffer, pH 7 (70:30:0.5) was used, with UV detection of the effluent at 220 nm. Azidocillin potassium salt [potassium-6-(d-(-)-α-azidophenyacetamido)-penicillanate] was used as the internal standard and quantitation was based on peak height ratio of amdinocillin to that of the internal standard. The assay has a recovery of 74.4 ± 6.3% (S.D.) in the concentration ranges of 0.1–20 μg per 0.2 ml of plasma with a limit of detection equivalent to 0.5 μg/ml plasma. The urine assay was validated over a concentration range of 0.025–5 mg/ml of urine, and has a limit of detection of 0.025 mg/ml (25 μg/ml) using a 0.1-ml urine specimen per assay.The assay was applied to the determination of plasma and urine concentrations of amdinocillin following intravenous administration of a 10 mg/kg dose of amdinocillin to two human subjects. The HPLC and microbiological assays were shown to correlate well for these samples.  相似文献   

7.
8.
9.
A rapid, sensitive and selective high-performance liquid chromatographic (HPLC) assay was developed for the determination of cibenzoline (Cipralan TM) in human plasma and urine. The assay involves the extraction of the compound into benzene from plasma or urine buffered to pH 11 and HPLC analysis of the residue dissolved in acetonitrile---phosphate buffer (0.015 mol/1, pH 6.0) (80:20). A 10-μ ion-exchange (sulfonate) column was used with acetonitrile—phosphate buffer (0.015 mol/1, pH 6.0) (80:20) as the mobile phase. UV detection at 214 nm was used for quantitation with the di-p-methyl analogue of cibenzoline as the internal standard.The recovery of cibenzoline in the assay ranged from 60 to 70% and was validated in human plasma and urine in the concentration range of 10–1000 ng/ml and 50–5000 ng/ml, respectively. A normal-phase HPLC assay was developed for the determination of the imidazole metabolite of cibenzoline. The assays were applied to the determination of plasma and urine concentrations of cibenzoline and trace amounts of its imidazole metabolite following oral administration of cibenzoline succinate to two human subjects.  相似文献   

10.
A rapid, reliable and specific reversed-phase high-performance liquid chromatographic procedure is described for the determination of diphenylpyraline hydrochloride at nanogram concentrations in plasma and urine. After extraction of the drug with n-pentane-2-propanol (50:1) from alkalinized samples, the organic extract was evaporated to dryness, reconstituted with methanol and chromatographed using a 5-μm Asahipak ODP-50 C18 column with UV detection at 254 nm. The elution time for diphenylpyraline was 7.9 min. The overall recovery of diphenylpyraline from spiked plasma and urine samples at concentrations ranging from 53 to 740 ng/ml were 94.65% and 92.29%, respectively. Linearity and precision data for plasma and urine standards after extraction were acceptable. The limit of detection was 15 ng/ml for both plasma and urine samples at 0.002 AUFS.  相似文献   

11.
12.
Enantiomers of salbutamol were directly separated (Rs=1.16) and quantitated at therapeutic concentrations after solid-phase extraction from human plasma and urine by normal-phase high-performance liquid chromatography on a chiral column with fluorescence detection. The assay was linear for each enantiomer between 1.25 and 500 ng ml−1 and had a minimum limit of detection of 250 pg ml−1. A 3-ml plasma or 1-ml urine sample was required for quantitation at therapeutic doses. Inter-day variation was 50% for S-(+)- and 6.5% for R-(−)-salbutamol. The assay was used to compare enantioselective disposition after single doses of racemate by the intravenous, oral and rectal routes.  相似文献   

13.
This paper describes a precise and sensitive method for analysis of nalidixic acid and its two major metabolites in plasma and urine following the oral administration of a therapeutic dose in humans. After addition of an internal standard (oxolinic acid), 1-ml samples of plasma or urine are extracted at acidic pH with chloroform. The extracts are purified by re-extraction with sodium hydroxide solution and then chloroform. The final extracts are evaporated to dryness, reconstituted in mobile phase and injected into a high-performance liquid chromatograph equipped with RP-8 column and UV detector operating at 254 nm. The limit of sensitivity of the method is lower than 0.5 μg/ml of plasma or urine for each compound. The applicability of the method to pharmacokinetic studies of nalidixic acid in humans is demonstrated.  相似文献   

14.
An automated method, based on column-switching reversed-phase high-performance liquid chromatography, has been developed for the determination of a major metabolite of tipredane in rat urine. Samples are injected directly onto a cyanopropyl extraction column. The portion of eluate containing the metabolite is switched, via an injection loop, onto an octadecylsilane analytical column. The limit of quantification of the method was 25 ng/ml for a 20 μl injection volume of urine. The intra-assay precision (0.7–4.8%) and accuracy (94–105%), and the inter-assay precision (2.7–12.6%) and accuracy (94–105%), were acceptable. The analyte was found to be stable in rat urine when stored at room temperature for six days, in a freezer at or below −20°C for twelve weeks, and when the samples were subjected to two freeze–thaw cycles. No significant interference was observed from tipredane and its major human metabolites, or urine constituents in male and female rats. The method was successfully used to analyse samples from a long-term toxicology study.  相似文献   

15.
A high-performance liquid chromatographic method for the determination of the histamine H1-receptor antagonist cetirizine in human urine was developed. Cetirizine and the internal standard are extracted from acidified (pH 5) urine (0.5 ml) into chloroform and the organic layer is evaporated to dryness. The residue is chromatographed on a Spherisorb 5ODS-2 column using Pic A (5 mM aqueous tetrabutylammonium phosphate)—methanol—tetrahydrofuran (33:65:2, v/v) as the mobile phase with ultraviolet detection (230 nm). The calibration graph is linear from 0.1 to 10 μg/ml and using 0.5 ml of urine the detection limit is 20 ng/ml. The within-run relative standard deviation is <6% and the accuracy is within 10% of the theoretical value at concentrations between 0.1 and 10 μg/ml in urine. There is a good correlation (r = 0.99606) with a previously described capillary gas chromatographic assay.  相似文献   

16.
A method for the quantitation of theophylline (13DMX) and the three metabolites, 1-methyluric acid (1MU), 3-methylxanthine (3MX) and 1,3-dimethyluric acid (13DMU) in human plasma and urine has been developed. The method is based on a simple one-step liquid-liquid extraction with ethylacetate-2 propanol followed by isocratic, reversed-phase high-performance liquid chromatography with UV detection (detection wavelength: 273 nm). The overall mean recoveries ranged from 86 to 95% for the four compounds. The detection limit was 1 μm for 1MU, 3MX and 13DMU and 2 μM for 13DMX in urine, and 0.1 μM for 1MU, 3MX and 13DMU and 0.2 μM for 13DMX in plasma. The intra-day and inter-day coefficient of variation was <6% and <9%, respectively, and the accuracy was within ±10% in both urine and plasma.The simple but sensitive method is highly suitable for the development of theophylline as a probe drug for assessing CYP1A2 activity in man.  相似文献   

17.
A sensitive and reproducible method is described for the determination of the cytochrome P450 enzyme 2E1 substrate chlorzoxazone and its primary metabolite 6-hydroxychlorzoxazone in human plasma and urine. Plasma or diluted urine were acidified, incubated with β-glucuronidase and then were extracted with diethyl ether. Separation of the analytes was achieved on a C18 column with UV detection set at 283 nm. Excellent linearity was observed over the concentration ranges of 100–3000 ng/ml and 4–400 μg/ml in plasma and urine, respectively. The intra-assay variability was 5.1% and the inter-assay variability was 8.2% for each compound in each matrix. The method presented is applicable to pharmacokinetic and pharmacogenetic studies utilizing chlorzoxazone.  相似文献   

18.
As a part of a pilot clinical study, a high-performance reversed-phase liquid chromatography analysis was developed to quantify temozolomide in plasma and urine of patients undergoing a chemotherapy cycle with temozolomide. All samples were immediately stabilized with 1 M HCl (1 + 10 of biological sample), frozen and stored at −20°C prior to analysis. The clean-up procedure involved a solid-phase extraction (SPE) of clinical sample (100 μl) on a 100-mg C18-endcapped cartridge. Matrix components were eliminated with 750 μl of 0.5% acetic acid (AcOH). Temozolomide was subsequently eluted with 1250 μl of methanol (MeOH). The resulting eluate was evaporated under nitrogen at RT and reconstituted in 200 μl of 0.5% AcOH and subjected to HPLC analysis on an ODS-column (MeOH-0.5% AcOH, 10:90) with UV detection at 330 nm. The calibration curves were linear over the concentration range 0.4–20 μg/ml and 2–150 μg/ml for plasma and urine, respectively. THe extraction recovery of temozolomide was 86–90% from plasma and 103–105% from urine over the range of concentrations considered. The stability of temozolomide was studied in vitro in buffered solutions at RT, and in plasma and urine at 37°C. An acidic pH (<5–6) shoul be maintained throughout the collection, the processing and the analysis of the sample to preserve the integrity of the drug. The method reported here was validated for use in a clinical study of temozolomide for the treatment of metastatic melanoma and high grade glioma.  相似文献   

19.
A simple and sensitive high-performance liquid chromatographic method for the simultaneous assay of amiodarone and desethylarniodarone in plasma, urine and tissues has been developed. The method for plasma samples and tissue samples after homogenizing with 50% ethanol, involves deproteinization with acetonitrile containing the internal standard followed by centrifugation and direct injection of the supernatant into the liquid chromatograph. The method for urine specimens includes extraction with a diisopropyl ether—acetonitrile (95:5, v/v) mixture at pH 7.0 using disposable Clin-Elut 1003 columns, followed by evaporation of the eluate, reconstitution of the residue in methanol—acetonitrile (1:2, v/v) mixture and injection into the chromatograph. Separation was obtained using a Radial-Pak C18 column operating in combination with a radial compression separation unit and a methanol–25% ammonia (99.3:0.7, v/v) mobile phase. A wavelength of 242 nm was used to monitor amiodarone, desethylamiodarone and the internal standard. The influence of the ammonia concentration in the mobile phase on the capacity factors of amiodarone, desethylamiodarone and two other potential metabolites, monoiodoamiodarone (L6355) and desiodoamiodarone (L3937) were investigated. Endogenous substances or a variety of drugs concomitantly used in amiodarone therapy did not interfere with the assay.The limit of sensitivity of the assay was 0.025 μg/ml with a precision of ± 17%. The inter- and intra-day coefficient of variation for replicate analyses of spiked plasma samples was less than 6%. This method has been demonstrated to be suitable for pharmacokinetic and metabolism studies of amiodarone in man.  相似文献   

20.
A sensitive and specific HPLC method has been developed for the assay of vigabatrin in human plasma and urine. The assay involves derivatization with 4-chloro-7-nitrobenzofurazan, solid-phase extraction on a silica column and isocratic reversed-phase chromatography with fluorescence detection. Aspartam was used as an internal standard. The assay was linear over the concentration range of 0.2–20.0 μg/ml for plasma and 1.0–15.0 μg/ml for urine with a lower limit of detection of 0.1 μg/ml using 0.1 ml of starting volume of the sample. Both the within-day and day-to-day reproducibilities and accuracies were less than 5.46% and 1.6%, respectively. After a single oral dose of 500 mg of vigabatrin, the plasma concentration and the cumulative urinary excretion of the drug were determined.  相似文献   