首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
This work presents the functional characterisation of a protein phosphatase 2A (PP2A) catalytic subunit obtained by genetic engineering and its conjugation to magnetic particles (MPs) via metal coordination chemistry for the subsequent development of assays for diarrheic lipophilic marine toxins. Colorimetric assays with free enzyme have allowed the determination of the best enzyme activity stabiliser, which is glycerol at 10%. They have also demonstrated that the recombinant enzyme can be as sensitive towards okadaic acid (OA) (LOD = 2.3 μg/L) and dinophysistoxin-1 (DTX-1) (LOD = 15.2 μg/L) as a commercial PP2A and, moreover, it has a higher operational stability, which makes possible to perform the protein phosphatase inhibition assay (PPIA) with a lower enzyme amount. Once conjugated to MPs, the PP2A catalytic subunit still retains its enzyme activity and it can also be inhibited by OA (LOD = 30.1 μg/L).  相似文献   

2.
In this protocol we present a rapid and sensitive assay for the accurate determination of protein concentration. The assay is a modification of a previous method, and measures minimum 0.2 μg protein.  相似文献   

3.
A high-throughput, homogeneous, fluorescence polarization, and fluorescence intensity assay has been developed for the measurement of folate in fruits and vegetables. This assay is based on the competitive displacement of the fluorescent folate ligands Alexa Fluor (Alexa) 594-folate and Alexa 660-folate from bovine milk folate-binding protein by folates in fruit and vegetable extracts. These fluorescent ligands are employed because their excitation and emission maxima are in regions of the spectrum with minimal autofluorescence in many extracts. Folate-binding protein and Alexa-folate were typically used at concentrations of 0.5 μg/ml and 5 nM, respectively, in 20-μl volumes in 384-well microplates. The assay is complete within 100 min. The folate estimate is unaffected by the heterogeneity of polyglutamyl residues that complicates the liquid chromatography-mass spectrometry (LC-MS)-based methods of quantification. In this assay, folic acid had an apparent affinity 2.5-fold greater than 5-methyltetrahydrofolate (5MTHF); therefore, it cannot be used to quantify folate when both natural and synthetic folate are present. 5MTHF-equivalent values were measured in broccoli (240 μg/100 g), strawberry (113 μg/100 g), white grape (32 μg/100 g), orange (44 μg/100 g), tomato (12 μg/100 g), raspberry (31 μg/100 g), banana (29 μg/g), and kiwifruit (36 μg/100 g). These data are similar to published values. However, the assay will not detect 5-formyltetrahydrofolate which is a significant constituent of the total folate in lettuce, spinach, carrot, and peppers.  相似文献   

4.
Here we present a comparison of commonly used methodologies for the extraction and quantification of konjac glucomannan (KGM). Compositional analysis showed that the purified konjac flour (PKF) produced using a modified extraction procedure contained 92% glucomannan, with a weight average molecular weight (Mw), polydispersity index (PDI) and degree of acetylation (DA) of 9.5 ± 0.6 × 105 g mol−1, 1.2 and 2.8 wt.%. These data, plus Fourier-transform infrared spectral (FTIR) and zero shear viscosity analyses of the extract (PKF) were all consistent with the literature. Comparison of three existing methodologies for the quantitative analysis of the KGM content of the PKF, namely 3,5-dinitrosalicylic acid (3,5-DNS), phenol-sulphuric acid and enzymatic colorimetric assays; indicated that the 3,5-DNS colorimetric assay was the most reproducible and accurate method, with a linear correlation coefficient of 0.997 for samples ranging from 0.5 to 12.5 mg/ml, and recoveries between 97% and 103% across three spiking levels (250, 500 and 750 μg/g) of starch. These data provide the basis of improved good laboratory practice (GLP) for the commercial extraction and analysis of this multifunctional natural polymer.  相似文献   

5.
A high-throughput fluorescence polarization assay has been developed for the detection of biotin and biotin-binding proteins in whole leaf extracts. Various groups are investigating the insecticidal properties of avidin and other biotin-binding proteins expressed in leaves of transgenic plants. The methods commonly used to quantify biotin and avidin in leaf extracts are enzyme-linked immunosorbent assay (ELISA) and Western blotting. Here we describe a homogeneous fluorescence polarization (FP) method that quantifies transgenic avidin in whole leaf extract by the simple addition of the fluorescent avidin ligand Alexa-Fluor 594 biocytin (AFB). The FP assay exploits the fact that AFB excites and emits in regions of the spectrum that are relatively free of background fluorescence in leaf extract. Transgenic leaf avidin can be quantified within 1-2 h by the FP method, in comparison with 1-2 days for ELISA and Western blotting. The FP method can also measure the amount of biotin in control leaves, not expressing avidin. Functional avidin levels of 1.54 μM (26.1 μg/g leaf tissue) were detected in tobacco leaves expressing vacuole-targeted avidin. Control leaves had biotin levels of around 0.74 μM (∼0.18 μg/g leaf tissue). Reagent costs are minimal: typically AFB is used at concentrations of 1-10 nM, avidin is used at 1-100 nM, and sample volumes are 20 μL in 384-well microplates.  相似文献   

6.
We developed a nonradioactive assay to measure spermidine/spermine N1-acetyltransferase (SSAT) activity by high-performance liquid chromatography (HPLC). N1-dansylnorspermine was prepared and evaluated as a substrate of acetylation with acetyl-CoA by SSAT in rat hepatoma (HTC) cells. Kinetic studies revealed that the Km values of N1-dansylnorspermine and acetyl-CoA were approximately 11 and 13 μM, respectively. When the assay method was applied to HTC cell samples, the SSAT activity, even at the control level, could easily be detected in as few as 20 μg protein of cell extract corresponding to 1 × 105 cells per determination, and 100 samples could be analyzed overnight. Thus, our HPLC method is a rapid and sensitive assay for the measurement of SSAT activity.  相似文献   

7.
A rapid and selective high performance liquid chromatography–tandem mass spectrometry (HPLC–MS/MS) method for simultaneous determination of isoniazid (INH), rifampicin (RFP) and levofloxacin (LVX) in mouse tissues and plasma has been developed and validated, using gatifloxacin as the internal standard (I.S.). The compounds and I.S. were extracted from tissue homogenate and plasma by a protein precipitation procedure with methanol. The HPLC separation of the analytes was performed on a Welch materials C4 column (250 mm × 4.6 mm, 5.0 μm, USA) at 25 °C, using a gradient elution program with the initial mobile phase constituting of 0.05% formic acid and methanol (93:7, v/v) at a flow-rate of 1.0 ml/min. For all the three analytes, the recoveries varied between 83.3% and 98.8% in tissues and between 75.5% and 90.8% in plasma, the accuracies ranged from 91.7% to 112.0% in tissues and from 94.6% to 108.8% in plasma, and the intra- and inter-day precisions were less than 13.3% in tissues and less than 8.2% in plsama. Calibration ranges for INH were 0.11–5.42 μg/g in tissues and 0.18–9.04 μg/ml in plasma, for RFP were 0.12–1200 μg/g in tissues and 4.0–200 μg/ml in plasma, and for LVX were 0.13–26.2 μg/g in tissues and 0.09–4.53 μg/ml in plasma. The lower limits of quantification (LLOQs) for INH, RFP and LVX in mouse tissues were 0.11, 0.12 and 0.13 μg/g and for those in mouse plasma were 18.1, 20.0 and 21.8 ng/ml, respectively. The limits of detection (LODs) for INH, RFP and LVX in mouse tissues were 0.04, 0.05 and 0.05 μg/g and for those in mouse plasma were 5.5, 6.0 and 6.6 ng/ml, respectively. The established method was successfully applied to simultaneous determination of isoniazid, rifampicin and levofloxacin in mouse plasma and different mouse tissues.  相似文献   

8.
In this article, we present a modified and improved protein assay that was previously described as “amidoschwarz assay” by Schaffner and Weissmann [13]. Our improved protein assay is user-friendly and 30–40 times more sensitive than the earlier method. The assay was developed into three formats (macro-, micro-, and nanoassay) with trichloroacetic acid (TCA) as protein precipitating agent, measuring up to 96 samples. The macro and micro formats of this assay require a single reagent staining with amido black of protein dots bound to nitrocellulose membrane with lowest protein measurements to 1 and 0.1 μg, respectively. On the other hand, the nanoassay, with combination staining of amido black followed by colloidal gold, can extend the detection limit to 2.5 ng of protein. Protein concentrations were determined by densitometry and/or spectrophotometry. This assay is compatible with many ionic and non-ionic detergents. This improved protein assay provides an additional choice to researchers in measuring total protein concentration accurately in dilute biological samples as low as 0.125 μg/ml prior to their biochemical analysis such as in comparative proteomics.  相似文献   

9.
A rapid, inexpensive, sensitive and specific HPLC-ECD method for the determination of lipoic acid in human plasma was developed and validated over the linearity range of 0.001–10 μg/ml using naproxen sodium as an internal standard (IS). Extraction of lipoic acid and IS from plasma (250 μl) was carried out with a simple one step liquid–liquid extraction using dichloromethane. Similarly solid-phase extraction was carried out using dichloromethane as extraction solvent. The separated organic layer was dried under the stream of nitrogen at 40 °C and the residue was reconstituted with the mobile phase. Complete separation of both lipoic acid and IS at 30 °C on Discovery HS C18 RP column (250 mm × 4.6 mm, 5 μm) was achieved in 6 min using 0.05 M phosphate buffer (pH 2.5 adjusted with phosphoric acid):acetonitrile (50:50, v/v) as a mobile phase pumped at the rate of 1.5 ml/min using electrochemical detector in DC mode at the detector potential of 1.0 V. The limit of detection and limit of quantification of lipoic acid were 200 pg/ml and 1 ng/ml, respectively. While on column limit of detection and limit of quantification of lipoic acid were 10 and 50 pg/ml, respectively. The absolute recoveries of lipoic acid with liquid–liquid and solid-phase extraction were 98.43, 95.65, 101.45, and 97.36, 102.73, 100.17% at 0.5, 1 and 5 μg/ml levels, respectively. Coefficient of variations for both intra-day and inter-day were between 0.28 and 4.97%. The method is validated and will be quite suitable for the analysis of lipoic acid in the plasma of human volunteers as well as patients with diabetes and cardiovascular diseases.  相似文献   

10.
A sensitive and selective capillary electrophoresis method is developed, for the first time, for effective separation and simultaneous determination of aminomethylbezoic acid (PAMBA), cefminox sodium (CMNX) and etamsylate (ETM). The electrophoresis conditions were investigated and optimized. A 25 mM phosphate solution (pH 8.5) was used as a buffer and the peak area was determined with UV detection at 216 nm wavelength under 18 kV separation voltage. Under optimal conditions, the three drugs can be separated effectively. Good linearity was achieved in 3.13–150 μg/mL for PAMBA, 6.25–150 μg/mL for CMNX and 3.13–150 μg/mL for ETM, with the correlation coefficients of >0.999. The limit of detection (LOD) for PAMBA, CMNX and ETM was 1.04, 2.08 and 1.04 μg/mL, respectively. Their recoveries in human urine were in the range from 90.2% to 101% with the RSD (n = 5) of 0.7–3.1%. The proposed method is simple, rapid and accurate, and provides the sensitivity and linearity necessary for analysis of the test drugs in human urine at clinically relevant concentrations.  相似文献   

11.
We report a rapid and simple HPLC method with fluorescence detection for the quantification of the major flaxseed lignan, secoisolarisiresinol diglucoside (SDG) and its major metabolites. The method is specific for SDG, secoisolarisiresinol (SECO), enterodiol (ED) and entrolactone (EL) in rat serum. The assay procedure involves chromatographic separation using a Waters Symmetry C18 reversed-phase column (4.6 mm × 150 mm, 5 μm) and mobile phase gradient conditions consisting of acetonitrile (0.1% formic acid) and water (0.1% formic acid). SDG extraction from serum requires the use of Centrifuge filters while SECO, ED and EL are extracted with diethyl ether. The organic layer is evaporated and reconstituted in 100 μL of mobile phase and 50 μL of reconstituted sample or filtrate is injected onto the column. Total run time is 25 min. Calibration curves are linear (r2 ≥ 0.997) from 0.05 to 10 μg/mL for SDG and EL and 0.01–10 μg/mL for SECO and ED. Precision and accuracy are within USFDA specified limits. The stability of all lignans is established in auto-injector, bench-top, freeze–thaw and long-term stability at −80 °C for 30 days. The method's reasonable sensitivity and reliance on more widely available HPLC technology should allow for its straightforward application to pharmacokinetic evaluations of lignans in animal model systems such as the rat.  相似文献   

12.
The present study compared three methods for the determination of S-phenylmercapturic acid (S-PMA), a metabolite of benzene, in human urine: a HPLC/MS/MS technique with two different sample treatments (strong and partial hydrolysis) and a commercial assay based on anti-S-PMA monoclonal antibodies with chemiluminescence detection. Biological monitoring was done on 126 volunteers and the results were compared for the three methods and also with benzene exposure levels (range <3.0–592.5 μg/m3). The correlation between environmental monitoring data and S-PMA levels in non-smokers (n = 73) was highly significant (p < 0.0001, Student's t-test) for both HPLC/MS/MS methods (r = 0.65 both for strong acidic hydrolysis of the urine and hydrolysis at pH 2) but not for the immunoassay, which overestimated the S-PMA levels by about 8 μg/g creatinine (creat.). Therefore the immunoassay is only useful as a semiquantitative screening test, but quantitative results need to be confirmed by a more accurate method like HPLC/MS/MS. The HPLC/MS/MS procedure with strong acid hydrolysis led to a recovery of S-PMA about double that using pH 2 hydrolysis, giving more accurate results. The difference between the results with the two methods makes it difficult to compare the strong acidic hydrolysis data with the ACGIH BEI value of 25 μg/g creat. since the BEI® documentation is based on data collected in pH conditions that were not always controlled, which may underestimate the true S-PMA concentration. Besides, as levels of benzene exposure were high, smoking was not considered a confounding factor. The BEI for S-PMA in end of shift urine samples could be reconsidered when sufficient data are available from studies where the analyses are carried out in comparable conditions of hydrolysis and monitoring only non-smoking subjects.  相似文献   

13.
The ability of negatively charged phosphatidates to form complexes with Fe3+ ions was used to design a simple spectrophotometric assay for the quantitative determination of phosphatidic acid (PA). In the reaction with the purple iron(III)-salicylate, PA extracts Fe3+ ions and decreases the absorbance at 490 nm. Lower competition with salicylate for Fe3+ ions was observed with single negatively charged phosphatidates such as phosphatidylglycerol (PG), whereas neutral phosphatidates such as phosphatidylcholine (PC) and phosphatidylethanolamine (PE) showed no influence on the absorbance of the iron(III) complex. The detection limit of the method on a microplate scale was 10 μM PA. Based on these results, an assay for determining the activity of phospholipase D (PLD) toward natural phospholipids such as PC, PE, and PG was developed. In contrast to other spectroscopic PLD assays, this method is able to determine PLD activity toward different lipids or even lipid mixtures.  相似文献   

14.
In this study, we used native gradient-polyacrylamide gel electrophoresis and electroelution (NGGEE) to purify enzymatic proteins from Trichoderma koningii AS3.2774. With this method, we purified eight enzymatic proteins and classified them to the cellulase system by comparing secretions of T. koningii in inductive medium and in repressive medium. It resulted in 24-fold β-glucosidase (BG) purification with a recovery rate of 5.5%, and a specific activity of 994.6 IU mg− 1 protein. The final yield of BG reached 8 μg under purifying procedure of NGGEE. We also identified BG using the enzyme assay with thin-layer chromatography and MALDI-TOFMS. This BG had one subunit with a molecular mass of 69.1 kDa as determined by sodium dodecylsulfate-polyacrylamide gel electrophoresis. The hydrolytic activity of the BG had an optimal pH of 5.0, an optimal temperature of 50 °C, an isoelectric point of 5.68 and a Km for p-nitrophenyl-β-d-glucopyranoside of 2.67 mM. Taken together, we show that NGGEE is a reliable method through which μg grade of active proteins can be purified.  相似文献   

15.
3-Phenoxybenzoic acid (3-PBA) is a general metabolite of synthetic pyrethroids. It could be used as a generic biomarker for multiple pyrethroids exposure for human or pyrethroid residues in the environment. In this study, monoclonal antibodies (mAbs) against 3-PBA were developed by using PBA–bovine serum albumin (BSA) as an immunogen. In the competitive enzyme-linked immunosorbent assay (ELISA) format, the I50 and I10 values of purified mAbs were 0.63 and 0.13 μg/ml, respectively, with a dynamic range between 0.19 and 2.04 μg/ml. Then, the colloidal gold (CG)-based lateral flow immunoassay was established based on the mAbs. The working concentration of coating antigen and CG-labeled antibodies and the blocking effects were investigated to get optimal assay performance. The cutoff value for the assay was 1 μg/ml 3-PBA, and the detection time was within 10 min. A total of 40 river water samples were spiked with 3-PBA at different levels and determined by the lateral flow immunoassay without any sample pretreatments. The negative false rate was 2.5%, and no positive false results were observed at these levels. This lateral flow immunoassay has the potential to be an on-site screening method for monitoring 3-PBA or pyrethroid residues in environmental samples.  相似文献   

16.
The metabolic activity of suspension cultures of Sonneratia alba cells was quantified by measurement of the hydrolysis of fluorescein diacetate (FDA). FDA is incorporated into live cells and is converted into fluorescein by cellular hydrolysis. Aliquots (0.1–0.75 g) of S. alba cells were incubated with FDA at a final concentration of 222 μg/ml suspension for 60 min. Hydrolysis was stopped, and fluorescein was extracted by the addition of acetone and quantified by measurement of absorbance at 490 nm. Fluorescein was produced linearly with time and cell weight. Cells of S. alba are halophilic and proliferated well in medium containing 50 and 100 mM NaCl. Cells grown in medium containing 100 mM NaCl showed 2- to 3-fold higher FDA hydrolysis activity than those grown in NaCl-free medium. When S. alba cells grown in medium supplemented with 50 mM NaCl were transferred to fresh medium containing 100 mM mannitol, cellular FDA hydrolysis activity was down-regulated after 4 days of culture, indicating that the moderately halophilic S. alba cells were sensitive to osmotic stress. Quantification of cellular metabolic activity via the in vivo FDA hydrolysis assay provides a simple and rapid method for the determination of cellular activity under differing culture conditions.  相似文献   

17.
Biological monitoring of low level exposure to pollutants is a very challenging analytical activity, and the quality of results is difficult to assess, especially when a certified reference material is unavailable. The aim of this work was to evaluate the reliability of the assays used to measure urinary benzene (Benz-U) and S-phenylmercapturic acid (SPMA), by applying an internal quality control protocol. Urine spot samples from 705 subjects who were either members of the general urban population, gasoline station attendants, or refinery plant workers were assayed for Benz-U and SPMA, using GC/MS and LC/MS/MS, with quantification limits of 15 ng/L and 0.10 μg/L. The median Benz-U concentration was 263 ng/L (60-2789 ng/L, 5th-95th percentile), and the median SPMA concentration was 0.19 μg/L (<0.1-2.5 μg/L, 5th-95th percentile). Linearity of both assays was good, but a less-than-proportional response was found for SPMA concentrations below 1 μg/L. Between-run precision and accuracy for Benz-U concentration determination were assessed using quality controls at 120 ng/L and 1000 ng/L and were 10.3% and 4.8%, and 104.8% and 98.9%, respectively; while the precision and accuracy for SPMA concentration determination at 0.3 μg/L, 2.5 μg/L, and 20 μg/L were 40.3%, 6.2%, and 6.2%, and 48.3%, 96.3%, and 98.8%, respectively. Precision, estimated using duplicates of unknown samples, was 13.4% for Benz-U and 26.5% for SPMA analyses. Control charts for the means of the slope of the linear calibration curve of Benz-U showed good stability of the means over a five-year period. For SPMA, a two-laboratory comparison revealed acceptable agreement between ln-transformed data pairs, with a slope of the linear regression of 0.863 (confidence interval 0.774-0.952), null intercept, and a Pearson's r value of 0.844. Reliable results were obtained for Benz-U analyses over the entire concentration range, and for high and medium SPMA levels. However, the determination of SPMA concentrations at levels close to the limit of quantification was less reliable.  相似文献   

18.
A new simple, sensitive and precise liquid chromatography-tandem mass spectrometry method has been developed and validated for the determination of valacyclovir-HCl and acyclovir in tsetse flies (Glossina pallipides). Tsetse flies were extracted by ultrasonication with acidified methanol/acetonitrile, centrifuged and cleaned up by solid phase dispersion using MgSO4 and MSPD C18 material. Samples were analysed using a Waters Alliance 2695 series HPLC with a C18 Gemini analytical column (150 mm × 4.6 mm × 5 μm) and a guard cartridge column connected to a Waters Quattro-Micro triple-quadrupole mass spectrometer. The isocratic mobile phase consisted of methanol:acetonitrile:water (60:30:10, v/v/v) plus formic acid (0.1%) at a flow rate of 0.25 ml/min. The precursor > product ion transition for valacyclovir (m/z 325.1 > 152) and acyclovir (m/z 226.1 > 151.9) were monitored in positive electrospray multiple reaction monitoring mode. The method was validated at fortification levels of 0.5, 1 and 2 μg/g. The range of calibration for both drugs was 0.45-4.5 μg/g. The overall accuracy of the method was 92% for valacyclovir and 95% for acyclovir with corresponding within-laboratory reproducibilities of 4.4 and 3.4%, respectively. Mean recoveries were above 80% for both drugs and repeatability ranged from 0.7 to 6.1%. For both drugs the limits of detection and quantification were 0.0625 and 0.2 μg/g, respectively. The method was applied in experiments on the mass rearing of tsetse flies for sterile insect technique (SIT) applications, in which the flies were fed with blood meals containing acyclovir or valcyclovir-HCl prior to analysis to assess effects on Glossina pallidipes Salivary Gland Hypertrophy syndrome.  相似文献   

19.
A rapid, sensitive and simple high performance liquid chromatography–tandem mass spectrometry (HPLC–MS/MS) method was developed for determination of cefazedone in human plasma using metronidazole as internal standard (IS). The chromatographic separation was achieved on an Ultimate XB-CN column (2.1 mm × 150 mm, 5 μm) with an isocratic mobile phase of acetonitrile and 20 mM ammonium acetate in 0.1% formic acid in water (15:85, v/v). Detection was performed using electrospray ionization in positive ion multiple reaction-monitoring mode (SRM), monitoring the transitions m/z 548.2 → 344.1 for cefazedone and m/z 172.2 → 128.1 for IS. Calibration curves were linear over a wide range of 0.20–401.12 μg/mL for cefazedone in plasma. The lower limit of quantification (LLOQ) was 0.20 μg/mL. The intra- and inter-day precisions were less than 7.2%. The average recovery of cefazedone was 90.8–91.0%. The validated method was successfully applied to the pharmacokinetic study of cefazedone in Chinese healthy volunteers following intravenous (IV) administration of 500, 1000 and 2000 mg cefazedone injection.  相似文献   

20.
Protein l-isoaspartyl/d-aspartyl o-methyltransferase (PIMT) is a widely expressed protein repair enzyme that restores isomerized aspartyl residues to their normal configuration. Current methods for measuring PIMT activity have limited sensitivity or require radioactivity. We have developed a highly sensitive new assay method to measure PIMT activity in cell lysates. As a substrate, we used a fluorescently labeled delta sleep-inducing peptide (DSIP) that contains an isoaspartyl residue: 7-nitro-2,1,3-benzoxadiazole (NBD)-DSIP(isoAsp). The PIMT-catalyzed transfer of a methyl group onto this substrate can be detected with a simple high-performance liquid chromatography (HPLC) procedure. After the enzyme reaction, the methylated form of the peptide is stable and can be reproducibly separated from the unmethylated form in an acidic solvent and fluorometrically detected by HPLC. The limit of detection was estimated to be approximately 1 pmol of NBD-DSIP(isoAsp) (signal/noise ratio [S/N] = 3), and the quantitation limit of the activity was approximately 18 μg of total cell lysate from HEK293 cells (10.7 pmol/min/mg protein). This assay method is sensitive enough to detect PIMT activity in biological samples without the use of radioisotopes, offering significant advantages over previously reported methods.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号