首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
In the present study, immunomagnetic separation of Legionella pneumophila from mock bronchoalveolar lavage (BAL) fluid samples, which were artificially spiked with L. pneumophila, and culture positive patient BAL fluid samples, was achieved using BioMags (superparamagnetic particles) loaded with purified rabbit immunoglobulin G specific for L. pneumophila. Bacteria binding onto BioMag-immunomatrix were directly stained with a L. pneumophila species-specific DFA reagent and examined under a fluorescence microscope. BioMag-based immunomagnetic separation (BIMS) followed by DFA staining (BIMS-DFA) could correctly identify all the 20 (100%) BAL samples which were spiked with low numbers (2x10(2) CFU) of L. pneumophila. Cultures could be recovered from 15 (75%) of these 20 spiked BAL samples, 5 (25%) of the samples failed to yield positive cultures. Both culture and BIMS-DFA methods showed 100% positive results when spiked BAL samples containing high bacterial load (10(4) CFU) were tested. The findings with true patient culture positive BAL specimens which were examined retrospectively indicated that BIMS-DFA is significantly more sensitive for detecting L. pneumophila than conventional cytospin method of DFA staining (cytospin-DFA). Out of the 25 culture positive BAL specimens tested, 7 (28%) proved negative by cytospin-DFA whereas BIMS-DFA correctly detected all the 25 (100%) specimens. It is suggested that the BIMS-DFA procedure increases the sensitivity of DFA testing for L. pneumophila in large volume samples such as BAL fluids.  相似文献   

2.
Combination of the MAC (morphology, antibody, chromosomes) and harlequin staining procedures offers a method for direct analysis of cell kinetics in cultures of unfractionated hematopoietic cells. In the present study unfractionated human mononuclear leukocyte cultures were stimulated with PHA or PWM mitogens and exposed to bromodeoxyuridine for various periods. For MAC, cytospin preparations were made and cells were classified with monoclonal B and T antibodies by the immunoperoxidase technique. After differentiation of the different lymphocyte subsets, the cells were stained by a fluorescence-plus-Giemsa method to distinguish sister chromatids and to determine the proportions of first, second, third, or subsequent mitoses among the previously identified subsets. The results showed (1) that the relative proportions of mitotic T and B cells are the same regardless of the mitogen used; (2) that T and B lymphocytes proliferate faster in cultures stimulated by PWM than in those stimulated by PHA; and (3) that T cells enter mitosis earlier than B cells when PHA or PWM are used as mitogens.  相似文献   

3.
OBJECTIVE: To investigate variations in speed, duration and acceleration rate of the Cytospin 3 cytocentrifuge (Shandon Scientific Ltd., Astmoor, England) on the differential cell count of bronchoalveolar lavage (BAL) fluid samples. STUDY DESIGN: BAL fluid samples (n = 51) were cytocentrifuged at various combinations of speed (500, 1,200 and 2,000 rpm), acceleration rate (low, medium and high) and duration (5, 10, 15 and 20 minutes). The preparations were May-Grünwald-Giemsa stained and differentiated on 500 cells. Data were analyzed by mixed model repeated measurements ANOVA. RESULTS: The mean lymphocyte count was significantly higher at 1,200 rpm than at 500 rpm, whereas the macrophage count decreased. Between 1,200 and 2,000 rpm, the number of both cell types stabilized. Significantly higher numbers of lymphocytes were recorded at 10 and 15 minutes of cytocentrifugation than at 5 minutes. The acceleration rate did not influence the differential cell count. Seventeen BAL fluid samples were selected to test the diagnostic impact of cell damage using a validated computer program. In 1 of 17 samples the predicted diagnosis did not correspond between two different speeds (500 and 2,000 rpm). CONCLUSION: Variations in cytocentrifugation speed and duration affected the mean lymphocyte and macrophage counts of BAL fluid samples.  相似文献   

4.
We examined the effects of separation and freezing on fish leukocyte and erythrocyte morphology by light microscopy and on DNA content as measured by flow cytometry (FCM). Leukocytes and erythrocytes of largemouth bass Micropterus salmoides were isolated by density gradient centrifugation of whole blood, and frozen in liquid nitrogen in a buffer containing DMSO as a cryopreservative. The coefficient of variation (CV) of the G0/G1 peak of the cells was used to assess variation in nuclear DNA content within cell populations before and after separation and freezing treatments. In erythrocytes, the CV did not change significantly (P>0.05) when nuclei were isolated and stained without freezing or when erythrocytes were frozen prior to nuclear isolation and staining. In leukocytes, freezing and thawing prior to isolation and staining of nuclei significantly increased the CV (P<0.05), and produced hyperdiploid shoulders of the G0/G1 peak. However, the CV of leukocyte nuclei that were isolated and stained prior to freezing and the CV of non-frozen leukocyte nuclei did not differ (P>0.05). Microscopy showed that the freezing protocol had little effect on erythrocyte morphology, but caused irregular swelling in leukocytes. Freezing intact leukocytes also significantly (p<0.05) altered the apparent distribution of cells among the phases of the cell cycle as measured by FCM. The distributions of leukocyte nuclei that were isolated and stained prior to freezing were not different to non-frozen leukocytes. DNA measurements of nucleated blood cells are widely used in physiological, genetic and toxicological studies. Our results suggest that whole blood and erythrocytes for use in such studies can be frozen whole using a simple protocol, but leukocyte nuclei must be isolated and stained before freezing to avoid serious artifacts.  相似文献   

5.
OBJECTIVE: To investigate variations in the differential cell counts between the quadrants of cytocentrifuged bronchoalveolar lavage (BAL) fluid preparations and to evaluate the diagnostic impact of these differences in interstitial lung diseases (ILD). STUDY DESIGN: BAL fluid samples obtained from 30 patients suspected of having ILD or pneumonia were cytocentrifuged and additionally stained with May-Grünwald-Giemsa stain. Two observers differentiated 200 cells in each quadrant as well as in a circular pattern around the center of the cytocentrifuge spot. RESULTS: Lymphocytes and alveolar macrophages were not randomly distributed on the cytocentrifuge spot. Ten samples of patients with histologically confirmed ILD were selected to test the diagnostic impact using a validated computer program. The predicted diagnosis did not correspond to the histologic diagnosis for one quadrant from 1 of these 10 samples (sarcoidosis instead of idiopathic pulmonary fibrosis), whereas the differential cell counts performed around the center of the cytocentrifuge spot provided the correct diagnosis in all cases. CONCLUSION: BAL fluid differential cell counts varied between the quadrants of the cytocentrifuge spot. The center of the cytocentrifuge spot appeared to be the most reliable area. Therefore, cell counting is recommended in a circular pattern around the center of the cytocentrifuge spot.  相似文献   

6.
A double fluorescence assay has been employed for the detection of cell surface and/or cytoplasmic immunoglobulins (Ig) and the measurement of nuclear DNA content in the same cell. Following staining for Ig by means of FITC conjugated antibodies directed against heavy or light chains, cell suspensions or cytospin preparations were ethanol fixed and stained with a propidium iodide-RNAse solution. In this way, the cytometric DNA content of circulating B-lymphocytes was analyzed in three patients suffering from plasma cell malignancies with an excess of peripheral blood B-lymphocytes and evidence of aneuploid bone marrow plasma cells. Aneuploid circulating B-lymphocytes with the same DNA stem-line as bone marrow plasma cells were found in two patients with advanced disease but not in the only one we studied at presentation. Aneuploid lymphocytes had surface immunoglobulins bearing the same light chain as the M-protein. In addition, a significant percentage (23%) of cells lacking either surface or cytoplasmic immunoglobulins proved to be aneuploid in plasma cell leukemia. Nuclear DNA measurement combined with surface or cytoplasmic marker analysis appears to be a reliable method for studying neoplastic lymphoid precursor cells in plasma cell malignancies.  相似文献   

7.
We have studied 25 serous effusions containing definitive morphologic evidence of adenocarcinoma to evaluate the ability of two mucin stains (Mayer's mucicarmine, D-PAS) to detect intracytoplasmic mucin in both cytologic (cytospin) and corresponding histological (cell block) preparations. Mucicarmine stain was positive in six of 25 (24%) cytospins and 13 of 25 (52%) cell blocks. D-PAS was positive in 19 of 25 (76%) cytospins and 20 of 25 (80%) cell blocks. Eight cases were identified which showed mucicarmine positivity in the cell block but not the corresponding cytospin; prolonging incubation time resulted in a positive mucicarmine in cytospin preparations for seven of these cases. We conclude that: (i) D-PAS is a more sensitive stain for the detection of intracytoplasmic mucin in all preparations; (ii) mucicarmine shows preferential staining for cell blocks; (iii) alterations in the staining protocol may permit mucin detection by mucicarmine staining in cytologic preparations in a significant number of cases.  相似文献   

8.
《The Journal of cell biology》1989,109(6):3169-3182
We have localized several major extracellular matrix protein receptors in the specific granules of human polymorphonuclear (PMN) and monocytic leukocytes using double label immunoelectron microscopy (IEM) with ultrathin frozen sections and colloidal-gold conjugates. Rabbit antibodies to 67-kD human laminin receptor (LNR) were located on the inner surface of the specific granule membrane and within its internal matrix. LNR antigens co-distributed with lactoferrin, a marker of specific granules, but did not co-localize with elastase in azurophilic granules of PMNs. Further, CD11b/CD18 (leukocyte receptor for C3bi, fibrinogen, endothelial cells, and endotoxin), mammalian fibronectin receptor (FNR), and vitronectin receptor (VNR) antigens were also co- localized with LNR in PMN specific granules. A similar type of granule was found in monocytes which stained for LNR, FNR, VNR, CD18, and lysozyme. Activation of PMNs with either PMA, f-met-leu-phe (fMLP), tumor necrosis factor (TNF), or monocytic leukocytes with lipopolysaccharide (LPS), induced fusion of specific granules with the cell membrane and expression of both LNR and CD18 antigens on the outer cell surface. Further, stimulation led to augmented PMN adhesion on LN substrata, and six- to eightfold increases in specific binding of soluble LN that was inhibited by LNR antibody. These results indicate that four types of extracellular matrix receptors are located in leukocyte specific granules, and suggest that up-regulation of these receptors during inflammation may mediate leukocyte adhesion and extravasation. We have thus termed leukocyte specific granules adhesomes.  相似文献   

9.
MOPC-315 murine myeloma grown intraperitoneally as ascites cells in BALB/cJ mice were removed at successive days after transplantation. They were stained for Id315 and I-A markers by indirect immunofluorescence techniques by means of FITC conjugates. Flow cytometry (FCM) measurements on cell surface markers were correlated with the phase of the cell cycle by quantitating cellular DNA of cells stained with propidium iodide. Variations in cell size due to cell growth were determined by low-angle light scattering. FCM data on the two cell surface markers were normalized for unit cell surface and cell volume. Cells grew rapidly in the early days (5–7) of tumor growth. No significant variation in the expression of surface markers was observed during this period. Parallel with a slowdown in cell growth, the expression of Id315 increased about threefold between the 7th and 9th days. The increase in the Id315 marker was dependent on the cell cycle, with G1 cells having the highest density. No cell cycle dependence was observed for the I-A marker.  相似文献   

10.
In this study flow cytometric and morphologic methods of apoptosis detection in human promyelocytic leukemia cell line HL-60 were compared. HL-60 cells were harvested at 4, 7, 16, 24 a 48 hours after induction of apoptosis by 3 % ethanol. Little changes were observed both by flow cytometry (decrease of forward scatter, increase of unprocessed cells staining with APO2.7 antibody) and viability determination by Trypan-blue staining until after 7 hours. However, after 4 hours morphologic changes were observed in the nuclear and cytoplasmic structures using Diff-Quik stained cytospin preparations and standard light microscopic techniques (50% apoptotic cells). The same results were obtained by flow cytometric measurement of sub-diploid DNA content (sub-G1 cells), and an increase of staining with APO2.7 antibody in cells permeabilised by digitonin prior to staining. After 7 hours almost all cells exhibited apoptotic morphology. After 16 hours the cell size (forward scatter) decreased significantly, and 54% of unprocessed cells were APO2.7 positive. After 24 hours only 6% of cells were alive (high forward scatter) and these cells were APO2.7 negative. The HL-60 cells did not proliferate during the cultivation in 3% ethanol, and after 48 hours all stained by Trypan blue. HL-60 leukemic cells were CD34-/AC133-, CD33+/CD15+, and only 2% of the cells were CD95+. Induction of apoptosis by ethanol did not enhance CD95 antigen expression.  相似文献   

11.
BACKGROUND: Flow cytometry (FCM) and laser scanning cytometry (LSC) are the routine techniques for fluorescent cell analysis. Recently, we developed a scanning fluorescent microscopy (SFM) technique. This study compares SFM to LSC (two slide-based cytometry, SBC, techniques) and FCM, in experimental and clinical settings. METHODS: For the relative cell-frequency determinations, HT29 colorectal cancer cells and Ficoll separated blood mononuclear cells (FSBMCs) were serially diluted (from 1:1 to 1:1,000) and measured by each of the three techniques. For the absolute cell number determinations (only for SBC) FSBMCs were smeared on slides, then HT29 cells were placed on the slide with a micromanipulator (5-50 cells). Tumor cells circulating in the peripheral blood were isolated by magnetic separation from clinical blood samples of colorectal cancer patients. All samples were double-stained by CD45 ECD and CAM5.2 FITC antibodies. For slides, TOTO-3 and Hoechst 33258 DNA dyes were applied as nuclear counter staining. RESULTS: In the relative cell frequency determinations, the correlations between the calculated value and measured values by SFM, LSC, and FCM were r(2) = 0.79, 0.62, and 0.84, respectively (for all P < 0.01). In the absolute cell frequency determinations, SFM and LSC correlated to a high degree (r(2) = 0.97; P < 0.01). CONCLUSIONS: SFM proved to be a reliable alternative method, providing results comparable to LSC and FCM. SBC proved to be more suitable for rare-cell detection than FCM. SFM with digital slides may prove an acceptable adaptation of conventional fluorescent microscopes in order to perform rare-cell detection.  相似文献   

12.
Ferrari BC  Vesey G  Davis KA  Gauci M  Veal D 《Cytometry》2000,41(3):216-222
BACKGROUND: Cryptosporidium is an important waterborne pathogen. Detection of Cryptosporidium in concentrated water samples depends on oocyst isolation using immunomagnetic separation (IMS) and/or fluorescence-activated cell sorting (FACS), followed by confirmation using immunofluorescence staining (IFA) and fluorescence microscopy. These methods require highly trained microscopists for oocyst identification and confirmation. Analysis is hampered due to the presence of autofluorescent particles coupled with particles binding nonspecifically with the monoclonal antibodies (mAbs) used for detection. Flow cytometry (FCM) has the potential to be a more specific method for oocyst detection, but such a system would require more than one selection parameter. METHODS: Various mAbs from commercial suppliers were paired with CRY104-PE and evaluated. The mAb combination that best discriminated stained oocyst from detritus was optimized and compared to Cryptosporidium detection utilizing one-color IFA/FACS. RESULTS: A highly specific two-color assay employing the IgG(1) mAb CRY104 was developed. The assay resulted in reductions, up to 20-fold, in the number of non-Cryptosporidium particles detected. The addition of a second selection parameter improved microscopic analysis times and simplified oocyst confirmation by microscopists. CONCLUSIONS: A two-color assay employing competing surface mAbs reduces the number of fluorescent particles sorted, thus improving FCM detection methods for Cryptosporidium.  相似文献   

13.
It is generally accepted that physiological modulators for tumour necrosis factor (TNF) are present in a variety of body fluids including serum. Among these modulators are soluble TNF receptors (TNF-R) that are cleaved from the extracellular domain of the TNF-Rs. Two receptors of different structures with molecular weights of 55 kDa (CD120a) and 75 kDa (CD120b) are known to be expressed on monocytes, lymphocytes, granulocytes and other cells of peripheral blood. The aim of our study was to determine the expression of CD120a and CD120b on bronchoalveolar lavage cells (BAL cells). BAL cells of 14 patients with different pulmonary disorders were stained with anti-CD120a and anti-CD120b monoclonal antibodies and were differentiated by FACS analysis. Both TNF-Rs are expressed on monocytes, macrophages, lymphocytes and granulocytes of the BAL. Although the relation of CD120a to CD120b is individual for a given cell type and an individual patient, strict correlations between both receptors were observed for BAL monocytes and alveolar macrophages. CD120a are expressed on 29.7% of alveolar macrophages; similar data were obtained for CD120b. 24.3% of the BAL monocytes were positive for CD120a and 25.5% for CD120b. 4.1% of the BAL lymphocytes were positive for CD120a whereas the percentage of CD120b positive BAL lymphocytes was approximately six times greater. Analysis of BAL granulocytes revealed 21.2% cells positive for CD120a and 11.6% for CD120b. In contrast to the BAL cells named above there was no positive correlation between CD120a and CD120b expression on BAL lymphocytes and granulocytes. We were able to show that TNF-Rs of BAL cells, like those of blood cells, are shedded in vitro after incubation with or without lipopolysaccharide (LPS), detected as TNFalpha-inhibitor activity in cell culture supernatant. In conclusion, BAL cells express and shed TNF-Rs, as is known for cells of other body compartments.  相似文献   

14.
Postoperative edema and effusion (POEE) following cardiopulmonary bypass (CPB) surgery in children retards recovery and may aggravate postpericardiotomy (PPS), capillary leak syndrome (CLS), or multiorgan failure (MOF). Compared with complication-free children, POEE affected children have different preoperative serum levels of circulating cytokines and adhesion molecules. These levels may be used preoperatively to assess POEE, but their determination is time consuming, costly, and a substantial blood volume is required. Altered serum levels of cytokines and adhesion molecules also may be reflected in altered antigen expression on circulating blood leukocytes. The predictive potential of flow cytometric (FCM) leukocyte immunophenotyping was explored as a sensitive and fast method that required small blood samples. Blood samples taken 24 h preoperatively from 49 patients (3-18 years old) were stained with monoclonal antibodies for adhesion molecules (ICAM-1, LFA-1, Mac-1) or constitutive/activation markers (CD4, CD14, CD16, CD25, CD54, CD69, HLA-DR) and measured on a microbead calibrated FCM. Neutrophils, monocytes, and eosinophils from POEE patients express higher preoperative levels of LFA-1, monocytes, HLA-DR, and other activation markers (all P < 0.03). Over 89% of the patients were classified correctly by using two discriminant analysis methods (sensitivity, >76%; specificity, >86%; positive prediction, >80%; negative prediction, >83%). Granulocytes and monocytes of postoperative POEE patients exhibit significant preoperative immune activation, suggesting an increased risk for patients with atopic/allergic predisposition. Surgical trauma and CPB cause additional immune activation, leading to POEE by a summative response. Most patients at risk for POEE can be identified preoperatively by using data pattern analysis on FCM-derived parameters.  相似文献   

15.
Flow Cytometric Analysis of Marine Bacteria with Hoechst 33342   总被引:18,自引:8,他引:10       下载免费PDF全文
We investigated the accuracy and precision of flow cytometric (FCM) estimates of bacterial abundances using 4′, 6-diamidino-2-phenylindole (DAPI) and Hoechst 33342 (HO342, a bisbenzamide derivative) on paraformaldehyde-fixed seawater samples collected from two stations near Oahu, Hawaii. The accuracy of FCM estimates was assessed against direct counts by using epifluorescence microscopy. DAPI and HO342 differ in two aspects of their chemistry that make HO342 better suited for staining marine heterotrophic bacteria for FCM analysis. These differences are most important in studies of open-ocean ecosystems that require dual-beam FCM analysis to clearly separate heterotrophic bacterial populations from populations of photosynthetic Prochlorococcus spp. Bacterial populations were easier to distinguish from background fluorescence when stained with HO342 than when stained with DAPI, because HO342 has a higher relative fluorescence quantum yield. A substantially higher coefficient of variation of blue fluorescence, which was probably due to fluorescent complexes formed by DAPI with double-stranded RNA, was observed for DAPI-stained populations. FCM estimates averaged 2.0 and 12% higher than corresponding epifluorescence microscopy direct counts for HO342 and DAPI-stained samples, respectively. A paired-sample t test between FCM estimates and direct counts found no significant difference for HO342-stained samples but a significant difference for DAPI-stained samples. Coefficients of variation of replicate FCM abundance estimates ranged from 0.63 to 2.9% (average, 1.5%) for natural bacterial concentrations of 6 × 105 to 15 × 105 cells ml-1.  相似文献   

16.
In granulomatous inflammatory lung diseases such as sarcoidosis, the balance of cytokine production by activated T cells in the lungs may influence clinical disease outcome. To investigate the potential of T lymphocytes to produce cytokines and contribute to this process, T cells from bronchoalveolar lavage (BAL) and PB from 19 patients with active lung disease were stimulated, stained, and analysed by flow cytometry for intracellular production of cytokines and expression of the activation marker CD69. Higher proportions of BAL cells expressed CD69 compared with PB, in the absence of in vitro stimulation. The expression of IFN-γ was similar in unstimulated BAL and PB T cells, and there was no association between the expression of CD69 and IFN-γ. Following stimulation, there were increased numbers of IFN-γ+ T cells. A similar trend was found with IL-2+ T cells, but there were lower levels of IL-4+ T cells in BAL compared with PB, and similar levels of IL-10+ T cells. The presence of activated T lymphocytes in BAL samples from patients with sarcoidosis, with the potential to produce Th1 type 1 cytokines may contribute to the inflammatory processes in this granulomatous lung disease. The use of intracellular flow cytometry to investigate cytokine production by BAL T cells could help to indicate potential targets for future therapy.  相似文献   

17.
OBJECTIVE: To evaluate bronchoalveolar lavage (BAL) cytology and organism burden in patients with Pneumocystis carinii pneumonia (PCP) who were infected with the human immunodeficiency virus (HIV) and in those with other immunodeficiencies. STUDY DESIGN: BAL fluid samples from patients with PCP were selected (HIV-infected patients, n = 15; patients with other immunodeficiencies, n = 11). May-Grünwald-Giemsa-stained cytocentrifuge preparations were evaluated. Foamy alveolar casts (FACs) and P carinii clusters were counted. RESULTS: The numbers of FACs and P carinii clusters in BAL fluid samples of HIV-infected patients were significantly higher as compared to those in samples from patients with other immunodeficiencies. Striking cytologic findings observed in half the samples from both patient groups included the presence of foamy alveolar macrophages, activated lymphocytes, plasma cells and reactive type II pneumocytes. Furthermore, a peculiar cell type, "nonidentified cell" (NIC), was observed almost exclusively in BAL fluid samples from HIV-infected patients. CONCLUSION: BAL fluid samples from HIV-infected patients with PCP displayed higher organism burdens as compared to those from patients with other immunodeficiencies. Moreover, cytologic findings suggestive of noninfectious lung conditions were common in BAL fluid samples obtained from patients with PCP. Further study is required to elucidate the identity of the NIC cell type.  相似文献   

18.
目的:探讨流式细胞术(FCM)检测外周血淋巴细胞在淋巴瘤诊断中的应用价值。方法:通过筛选2011年8月至2017年8月期间初诊的皮肤淋巴瘤病例25例,淋巴节良性病变6例,采用FCM检测外周血淋巴细胞表面抗原分子,通过与病理切片HE染色和免疫组化法(金标准)比较,分析两种检测方法之间的差异。结果:在31例检测病例中,FCM检测结果与金标准检测结果一致性较高(Kappa=0.61):26例检查结果相同,5例检查结果不一致;检测19例T淋巴细胞淋巴瘤,FCM检测结果与金标准检测结果一致性也较高(Kappa=0.57):检测14例初诊为T细胞淋巴瘤病例,FCM检测T淋巴瘤细胞的表面抗原标志CD3分子为阳性,与组织学结果相符,另有5例T细胞淋巴瘤病例HE染色和免疫组化诊断明确,而FCM未能检出。检测6例B细胞淋巴瘤病例,6例淋巴瘤病例FCM检测结果都为阳性,FCM检测B淋巴瘤细胞的表面抗原标志CD19分子为阳性,与金标准检测结果符合率为100%。6例淋巴节良性病变病例FCM检测结果与金标准检测结果一致。结论:通过FCM检测外周血可以检测出部分皮肤淋巴瘤,FCM在皮肤淋巴瘤诊断和分型中有一定的临床价值,是检测皮肤淋巴瘤的有效的辅助方法。  相似文献   

19.
Described herein is a case of childhood Burkitt's lymphoma initially presenting as a pericardial effusion. A cytological diagnosis was made from a Wright's-Giemsa stained cytospin preparation. Supporting diagnostic evidence was provided by immunological surface marker analysis and electron microscopy. To our knowledge, Burkitt's lymphoma has not hitherto been diagnosed initially from the morphology of cells in pericardial fluid.  相似文献   

20.
BACKGROUND: Combined analysis of DNA content and immunofluorescence on single cells by flow cytometry provides information on the proliferative response of subpopulations to stimuli in mixed cell preparations; however, in low-viability cell preparations, dead cells interfere with accurate flow cytometric data analysis because of nonspecific binding of antibodies and altered DNA-staining profiles. Light scatter differences between nonviable and viable cells are unreliable, particularly after the cell permeabilization step that is necessary for DNA staining. We developed a method for identification of nonviable cells by fluorescence in cell preparations that are stained simultaneously for cell surface or intracellular immunofluorescence and DNA content. MATERIALS AND METHODS: Nonviable cells that have lost membrane integrity are identified by uptake of 7-amino-actinomycin D (7-AAD). Transfer of 7-AAD from stained nonviable cells to unstained viable cells after permeabilization is prevented by blocking DNA binding with nonfluorescent actinomycin D (AD). Pyronin Y(G) (PY) is used for DNA staining because the orange spectral emission of PY can be separated from the green fluorescein isothiocyanate (FITC) emission and the red emission of 7-AAD, respectively. RESULTS: Application of the method to the analysis of the T-cell leukemia cell line Molt-4f and of cultured human peripheral blood mononuclear cells is presented. In both cell preparations, 7-AAD staining permitted reliable dead cell exclusion. Live, 7-AAD-negative Molt-4f cells showed higher expression levels of cell surface CD4 and of intracellular CD3, showed a higher proportion of cells in the G1 phase of the cell cycle, and showed a lower coefficient of variation of the G1 peak compared with data obtained from all the cells in the preparation. Live, CD8+ lymphocytes from OKT3-stimulated cultures of human peripheral blood mononuclear cells showed a specific proliferative response as measured by DNA content analysis. CONCLUSIONS: The results show that cells stained with FITC-labeled antibodies can be analyzed by single-laser flow cytometry for DNA content combined with dead cell discrimination. Furthermore, they emphasize the need for exclusion of dead cells from the analysis of cell preparations with low viability to obtain reliable data on immunofluorescence and cell-cycle distributions.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏