首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.

Aim

This study evaluates the acute toxicity outcome in patients treated with RapidArc for localized prostate cancer.

Background

Modern technologies allow the delivery of high doses to the prostate while lowering the dose to the neighbouring organs at risk. Whether this dosimetric advantage translates into clinical benefit is not well known.

Materials and methods

Between December 2009 and May 2012, 45 patients with primary prostate adenocarcinoma were treated using RapidArc. All patients received 1.8 Gy per fraction, the median dose to the prostate gland, seminal vesicles, pelvic lymph nodes and surgical bed was 80 Gy (range, 77.4–81 Gy), 50.4 Gy, 50.4 Gy and 77.4 Gy (range, 75.6–79.2 Gy), respectively.

Results

The time between the last session and the last treatment follow up was a median of 10 months (range, 3–24 months). The incidence of grade 3 acute gastrointestinal (GI) and genitourinary (GU) toxicity was 2.2% and 15.5%, respectively. Grade 2 acute GI and GU toxicity occurred in 30% and 27% of patients, respectively. No grade 4 acute GI and GU toxicity were observed. Older patients (>median) or patients with V60 higher than 35% had significantly higher rates of grade ≥2 acute GI toxicity compared with the younger ones.

Conclusions

RapidArc in the treatment of localized prostate cancer is tolerated well with no Grade >3 GI and GU toxicities. Older patients or patients with higher V60 had significantly higher rates of grade ≥2 acute GI toxicity. Further research is necessary to assess definitive late toxicity and tumour control outcome.  相似文献   

2.
BackgroundThe aim of the study was to investigate the safety of combining preoperative stereotactic body radiotherapy (SBRT) with robotic radical prostatectomy (RP) for high risk prostate cancer (HRCaP). Many patients with HRCaP will require adjuvant or salvage radiotherapy after RP. The addition of preoperative SBRT before RP may spare patients from subsequent prolonged courses of RT.Materials and methodsEligible patients had NCC N HRCaP and received a total of 25 Gy or 30 Gy in five daily fractions of SBRT to the prostate and seminal vesicles followed by robotic RP with pelvic lymphadenectomy 31–45 days later. The primary endpoint was prevalence of acute genitourinary (GU) and gastrointestinal (GI) toxicity. Secondary endpoints were patient-reported quality of life (QOL) and biochemical recurrence (BcR).ResultsThree patients received preoperative SBRT to 25 Gy and four received 30 Gy. Median follow-up was 18 months. Highest toxicity was grade 2 and 3 in six (85.7%) and one (14.3%) patients, respectively. All patients developed grade 2 erectile dysfunction and 4 of 7 (57%) developed grade 2 urinary incontinence (UI) within a month after surgery. One patient developed acute grade 3 UI, but there was no grade ≥ 4 toxicity. One patient experienced acute grade 2 hemorrhoidal bleeding. On QOL, acute GU complaints were common and peaked within 3 months. Bowel symptoms were mild. Two patients with pN+ experienced BcR.ConclusionsPreoperative SBRT before robotic RP in HRCaP is feasible and safe. The severity of acute GU toxicity with preoperative SBRT may be worse than RP alone, while bowel toxicity was mild.  相似文献   

3.
BackgroundTo date, few studies have been published on image-guided helical tomotherapy (HT) in a moderate hypofractionation of localized PCa. We report outcome and toxicity of localized PCa patients treated with HT-based moderate hypofractionated radiotherapy.Materials and methods76 patients were retrospectively analyzed. A total dose of 60 Gy (20 × 3 Gy) or 67.5 Gy (25 × 2.7 Gy) was prescribed. The χ2 test was used to analyze associations between toxicity and dosimetric and clinical parameters. The Cox proportional hazard regression model was used for multivariate analysis. Kaplan-Meier method was used for survival analysis.Resultsmedian follow-up was 42.26 months [interquartile (IQR), 23–76). At 4-year, overall survival (OS) and metastasis-free survival (MFS) were 91% and 89%, respectively. At multivariate analysis, smoking habitude was associated with MFS [hazard ratio (HR) 7.32, 95% CI: 1.57–34.16, p = 0.011]. Acute and late grade ≥ 2 gastro-intestinal (GI) toxicity was observed in 6.5% and 2.6% of patients, respectively. Acute and late grade ≥ 2 genito-urinary (GU) toxicity were 31.5% and 3.9%. Four-year late GI and GU grade ≥ 2 toxicity were 3% and 7%, respectively. Acute GI toxicity was associated with statins medication (p = 0.04) and androgen deprivation therapy (p = 0.013). Acute GU toxicity was associated with the use of anticoagulants (p = 0.029) and antiaggregants (p = 0.013).ConclusionsHT-based moderate hypofractionation shows very low rates of toxicity. Smoking habitude is associated with the risk of developing metastases after radical treatment for localized PCa.  相似文献   

4.
AimThe purpose of this study was to review genitourinary (GU) and gastrointestinal (GI) toxicity associated with high-dose radiotherapy (RT) delivered with 3-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT) or volumetric arc therapy (VMAT) following radical prostatectomy (RP).BackgroundRP is a therapeutic option for the management of prostate cancer (PrCa). When assessing postoperative RT techniques for PrCa, the published literature focuses on patients treated with 2-dimensional conventional methods without reflecting the implementation of 3D-CRT, IMRT, or VMAT.Materials and methodsA total of 83 patients were included in this analysis; 30 patients received 3D-CRT, and 53 patients received IMRT/VMAT. Acute and late symptoms of the GU and lower GI tract were retrospectively graded according to the Radiation Therapy Oncology Group and the European Organization for Research and Treatment of Cancer radiation toxicity grading systems. The relapse failure-free rate and overall survival were also evaluated.ResultsThe rate of acute GU toxicity was 9.4% vs. 13.3% for the IMRT/VMAT and 3D-CRT groups (p = 0.583). The 5-year actuarial rates of late GI toxicity for IMRT/VMAT and 3D-CRT treatments were 1.9% and 6.7%, respectively. The rate of late GU toxicity for the IMRT/VMAT and 3D-CRT treatment groups was 7.5% and 16.6%, respectively (p = 0.199). We found no association between acute or late toxicity and the RT technique in univariate and multivariate analyses.ConclusionPostprostatectomy IMRT/VMAT and 3D-CRT achieved similar morbidity and cancer control outcomes. The clinical benefit of highly conformal techniques in this setting is unclear although formal analysis is needed.  相似文献   

5.
AimThe purpose of this study is to evaluate the long term tolerability of hypofractionated helical tomotherapy (HT) in localized prostate cancer patients.BackgroundPrevious hypofractionated schedules with conventional RT were associated with excessive toxicity, likely due to inadequate sophistication of treatment delivery. There are few data about late toxicity after HT.Materials and methodsWe evaluated 38 patients with primary adenocarcinoma of the prostate. There were 9 (24%), 15 (39%), and 14 (37%) patients with high, intermediate, and low risk, respectively. Patients were treated with hypofractionated HT from May 2008 to February 2011. Hypofractionation regimens included: 68.04 Gy at 2.52 Gy/fraction (N = 25; 66%), 70 Gy at 2.5 Gy/fraction (N = 4; 11%) and 70.2 Gy at 2.6 Gy/fraction (N = 9; 23%). Late genitourinary (GU) and gastrointestinal (GI) toxicity was scored using the Radiation Therapy Oncology Group scoring system.ResultsMedian age at diagnosis was 70 years (range 49–80) and median follow-up, 5.8 years. Late grade 1, 2 and 3 GI toxicity were 13%, 24%, and 2.6%, respectively. Late grade 1, 2, 3 GU toxicity were 29%, 21%, and 8%, respectively. Sexual toxicity was evaluated in 19 patients to be grade 1, 2 in 11% and grade 3 in 16%. Multivariate analysis showed that patients with higher values of rectum V50 associated with late GI toxicity (P = 0.025). Patients with PSA ≤8 (P = 0.048) or comorbidities (P = 0.013) at diagnosis were associated with higher late GU toxicity. Additionally, PSA ≤8 also associated with moderate (grade ≥2) late GU toxicity in the multivariate analysis (P = 0.028).ConclusionsHypofractionated HT can be delivered safely with limited rates of moderate and severe late toxicity. The proportion of the rectum that receives a moderate and high dose, having comorbidities, and PSA at diagnosis seem to associate with long term toxicity.  相似文献   

6.
AimTo investigate the predictive value of convenience of rectum dosimetry with Quantitative Analysis of Normal Tissue Effects in the Clinic (QUANTEC) dose limits, maximum rectum dose (Dmax), total rectal volume (TVrectum), rectal volume included in PTV (VrectumPTV) on Grade 2–3 acute rectal toxicity for utilization in clinical practice.BackgroundNumerous previous data have reported frequent acute proctitis after external-beam RT of prostate cancer. Predicting toxicity limited with dose information is inadequate in clinical practice due to comorbidities and medications used.Materials and MethodSixty-four non-metastatic prostate cancer patients treated with IMRT were enrolled. Patients were treated to a total dose of 70–76 Gy. Rectal dose volume histograms (DVH) of all patients were evaluated retrospectively, and a QUANTEC Score between 0 and 5 was calculated for each patient. The correlation between the rectal DVH data, QUANTEC score, TVrectum, VrectumPTV, rectum Dmax and Grade 2–3 rectal toxicity was investigated.ResultsIn the whole group grade 1, 2 and 3 acute rectal toxicities were 25%, 18.8% and 3.1%, respectively. In the DVH data, rectum doses of all patients were under RTOG dose limits. Statistically significant correlation was found between grade 2–3 rectal toxicity and TVrectum (p = 0,043); however. It was not correlated with QUANTEC score, VrectumPTV and Dmax.ConclusionOur results were not able to show any significant correlation between increasing convenience with QUANTEC limits and lower rectal toxicity. Conclusively, new dosimetric definitions are warranted to predict acute rectal toxicity more accurately in prostate cancer patients during IMRT treatment.  相似文献   

7.
AimTo report long-term data regarding biochemical control and late toxicity of simultaneous integrated boost intensity modulated radiotherapy (SIB-IMRT) with tomotherapy in patients with localized prostate cancer.BackgroundDose escalation improves cancer control after curative intended radiation therapy (RT) to patients with localized prostate cancer, without increasing toxicity, if IMRT is used.Materials and methodsIn this retrospective analysis, we evaluated long-term toxicity and biochemical control of the first 40 patients with intermediate risk prostate cancer receiving SIB-IMRT. Primary target volume (PTV) 1 including the prostate and proximal third of the seminal vesicles with safety margins was treated with 70 Gy in 35 fractions. PTV 2 containing the prostate with smaller safety margins was treated as SIB to a total dose of 76 Gy with 2.17 Gy per fraction. Toxicity was evaluated using an adapted CTCAE-Score (Version 3).ResultsMedian follow-up of living patients was 66 (20–78) months. No late genitourinary toxicity higher than grade 2 has been reported. Grade 2 genitourinary toxicity rates decreased from 58% at the end of the treatment to 10% at 60 months. Late gastrointestinal (GI) toxicity was also moderate, though the prescribed PTV Dose of 76 Gy was accepted at the anterior rectal wall. 74% of patients reported any GI toxicity during follow up and no toxicity rates higher than grade 2 were observed. Grade 2 side effects were reported by 13% of the patients at 60 months. 5-year freedom from biochemical failure was 95% at our last follow up.ConclusionSIB-IMRT using daily MV-CT guidance showed excellent long-term biochemical control and low toxicity rates.  相似文献   

8.
BackgroundThe purpose of this study was to assess the impact of coincidental radiotherapy on the volume of the non-malignant prostate gland in rectal cancer patients treated with neo-adjuvant radiotherapy.Materials and methodsIn this retrospective analysis, thirty male patients with rectal cancer who had neoadjuvant radiotherapy met the inclusion criteria. These patients had pre-treatment magnetic resonance imaging (MRI) and at least one post-treatment MRI of the pelvis and the whole of their prostate volume received the full prescribed radiotherapy dose; 45 Gy in 25 fractions (n = 22), 45 Gy in 20 fractions (n = 4) and 25 Gy in 5 fractions (n = 4).ResultsThe median age of this patient cohort was 66 years (range: 30–87). With a median interval between pre-treatment MRI and first MRI post-treatment of 2 months (range: 1–11), the mean prostate volume reduced from 36.1 cm3 [standard deviation (SD) 14.2] pre-radiotherapy to 31.3 cm3 (SD 13.0) post radiotherapy and this difference was significant (p = 0.0004).ConclusionRadiotherapy may cause shrinkage in volume of normal (non-malignant) prostate. Further research is required in this field, since these results may be of some comfort to men contemplating the consequences of radiotherapy on their quality of life. The authors suggest recording flow-rate and international prostate symptom score (IPSS) during rectal radiotherapy as a next step.  相似文献   

9.
AimTo assess a class solution template for volumetric-modulated arc therapy (VMAT) for prostate cancer using plan analysis software.BackgroundVMAT is a development of intensity-modulated radiotherapy (IMRT) with potential advantages for the delivery of radiotherapy (RT) in prostate cancer. Class solutions are increasingly used for facilitating RT planning. Plan analysis software provides an objective tool for evaluating class solutions.Materials and methodsThe class solution for VMAT was based on the current static field IMRT template. The plans of 77 prostate cancer patients were evaluated using a set of in-house plan quality metrics (scores) (PlanIQ™, Sun Nuclear Corporation). The metrics compared the class solution for VMAT planning with the IMRT template and the delivered clinical plan (CP). Eight metrics were associated with target coverage and ten with organs-at-risk (OAR). Individual metrics were summed and the combined scores were subjected to non-parametric analysis. The low-dose wash for both static IMRT and VMAT plans were evaluated using 40 Gy and 25 Gy isodose volumes.ResultsVMAT plans were of equal or better quality than the IMRT template and CP for target coverage (combined score) and OAR combined score. The 40 Gy isodose volume was marginally higher with VMAT than IMRT (4.9%) but lower than CP (−6.6%)(P = 0.0074). The 25 Gy volume was significantly lower with VMAT than both IMRT (−32.7%) and CP (−34.4%)(P < 0.00001).ConclusionsAutomated VMAT planning for prostate cancer is feasible and the plans are equal to or better than the current IMRT class solution and the delivered clinical plan.  相似文献   

10.

Aim

This study aimed at investigating factors associated to late rectal and bladder toxicity following radiation therapy and the effectiveness of Hyperbaric Oxygen Therapy (HBOT) when toxicity is grade ≥2.

Background

Radiation is frequently used for prostate cancer, but a 5–20% incidence of late radiation proctitis and cystitis exists. Some clinical and dosimetric factors have been defined without a full agreement. For patients diagnosed of late chronic proctitis and/or cystitis grade ≥2 treatment is not well defined. Hyperbaric Oxygen Therapy (HBOT) has been used, but its effectiveness is not well known.

Materials and methods

257 patients were treated with radiation therapy for prostate cancer. Clinical, pharmacological and dosimetric parameters were collected. Patients having a grade ≥2 toxicity were treated with HBOT. Results of the intervention were measured by monitoring toxicity by Common Toxicity Criteria v3 (CTCv3).

Results

Late rectal toxicity was related to the volume irradiated, i.e. V50 > 53.64 (p = 0.013); V60 > 38.59% (p = 0.005); V65 > 31.09% (p = 0.002) and V70 > 22.81% (p = 0.012). We could not correlate the volume for bladder. A total of 24 (9.3%) patients experienced a grade ≥2. Only the use of dicumarinic treatment was significant for late rectal toxicity (p = 0.014). A total of 14 patients needed HBOT. Final percentage of patients with a persistent toxicity grade ≥2 was 4.5%.

Conclusion

Rectal volume irradiated and dicumarinic treatment were associated to late rectal/bladder toxicity. When toxicity grade ≥2 is diagnosed, HBOT significantly ameliorate symptoms.  相似文献   

11.
BackgroundThe purpose of the study was to evaluate the toxicity and outcome of nasopharyngeal carcinoma patients treated using 3-dimensional conformal radiotherapy (3DCRT) or volumetric modulated arc therapy (VMAT) technique.Materials and methods68 patients treated between 2006 and 2018 were retrospectively analysed. Since 2009 patients received 3DCRT with 50/70 Gy to the elective/boost volumes in 35 fractions; from then, VMAT with simultaneous integrated boost (SIB) with 54.45/69.96 Gy in 33, or 54/66 Gy in 30 fractions. Induction chemotherapy was administered in 74% of the patients, concomitant cisplatinum in 87%. Acute and late toxicity data, progression-free survival PSF and overall survival OS, and toxicity correlations with dose metrics were reported.ResultsWith a median follow-up of 64 months, complete remission at the last evaluation was in 68% of the patients, while 28% and 9% had locoregional relapse and distant disease, respectively. The 5- and 10-year progression free survival (PFS) rates were 62.7 ± 6.5% and 53.2 ± 8.7%, respectively. The 5- and 10-year OS rates were 78.9 ± 5.5% and 61.4 ± 9.2%, respectively. At the multivariate Cox analysis TNM stage (p = 0.02) and concomitant chemotherapy (p = 0.01) resulted significant for PFS, concomitant chemotherapy (p = 0.04) for OS.Improvements in acute toxicity were presented for VMAT patients due to its ability to spare OARs. Odds ratio (OR) for acute salivary toxicity, between VMAT and 3DCRT, was 4.67 (p = 0.02). Dosimetrically, salivary toxicity correlated with mean parotid dose (p = 0.05), dysphagia with laryngeal (p = 0.04) and mean oral cavity (p = 0.06) doses, when dose-volume histograms (DVHs) are corrected for fractionation.ConclusionThis study is a proof of a significant benefit of the VMAT technique compared with 3DCRT in terms of side effects in nasopharynx patients, and adds dosimetric correlations.  相似文献   

12.
AimThis study aimed to investigate whether IMRT using VMAT is a viable and safe solution in dose escalated RT in these patients.BackgroundAn increasing number of prostate cancer patients are elderly and have hip prostheses. These implants pose challenges in radiotherapy treatment planning. Although intensity modulated radiotherapy (IMRT) is commonly used, there is a lack of clinical studies documenting its efficacy and toxicities in this subgroup of patients.Materials and methodsThe data from 23 patients with hip prostheses and non-metastatic prostate cancer treated with VMAT (volumetric modulated arc therapy) between 2009 and 2011, were retrospectively analyzed. Baseline characteristics, treatment details and outcome data were collected on all patients. The median follow up was 40.9 months. MRI-CT image fusion was performed and the treatment plans were created using RapidArc™ (RA) techniques utilizing 1 or 2 arcs and 10 MV photon beams.Results96% of patients were treated with a dose of 72 Gy/32 fractions over 44 days. 21/23 plans met the PTV targets. The mean homogeneity index was 1.07. 20/23 plans met all OAR constraints (rectum, bladder). Two plans deviated from rectal constraints, four from bladder constraints; all were classed as minor deviations. One patient experienced late grade 3 genitourinary toxicity. Three other patients experienced late grade 2 or lower gastrointestinal toxicity. One patient had biochemical failure and one had a non-prostate cancer related death.ConclusionsVMAT provides an elegant solution to deliver dose escalated RT in patients with unilateral and bilateral hip replacements with minimal acute and late toxicities.  相似文献   

13.
BackgroundThe objective of this study was To determine the dose volume parameters predicting acute haematological toxicity in carcinoma cervix patients undergoing concurrent chemoradiotherapy.Materials and methodsAll patients that presented to the hospital between Jan 2019 and Dec 2019 were prospectively analyzed. Patients diagnosed to have Carcinoma Cervix and planned for concurrent chemoradiation by volumetric modulated arc therapy (VMAT) were included for analysis. Patients were assessed at baseline and every week during treatment for acute haematological toxicities. Dose volume parameters from treatment plans were correlated with RTOG grade of haematological toxicities.ResultsA total of 34 patients diagnosed to have squamous cell carcinoma of cervix were treated by radical radiotherapy by VMAT technique and concurrent chemotherapy. The most common stage of presentation was stage IIB (61.7%). 29 patients (85.2%) completed five cycles of weekly cisplatin. Statistical analysis for sensitivity and specificity of dosimetric parameters was performed using receiver operating characteristic (ROC) curve. The probability of developing bone marrow toxicity was analyzed using T test. Mean dose to bone marrow exceeding 28.5 Gy was significantly associated with bone marrow toxicity (sensitivity — 82.4%, specificity — 70.6%). On analyzing dose volume parameters, volume of bone marrow receiving 20 Gy, 30 Gy and 40 Gy (V20, V30 and V40) more than 71.75%, and 49.75% and 22.85%, respectively, was significantly associated with bone marrow toxicity.ConclusionsOur study concludes that mean dose to bone marrow exceeding 28.5 Gy has high sensitivity and specificity for predicting bone marrow toxicity in patients receiving IMRT. Volume of bone marrow receiving 20 Gy, 30 Gy and 40 Gy significantly correlated with acute haematological toxicity.  相似文献   

14.
15.
BackgroundAbout 5% of prostate cancer cases are metastatic at diagnoses. Radiotherapy of both primary tumor and secondary lesions can be, in addition to systemic treatments, a radical alternative for selected patients.Materials and methodsPatients with de novo prostate carcinoma with bone or lymph node metastases were retrospectively reviewed. All patients received moderate hypofractionated IMRT/VMAT up to 63 Gy in 21 daily fractions of 3 Gy to prostate and metastases with neoadjuvant and concurrent androgen deprivation therapy (ADT). According to known advances some patients also received abiraterone, enzalutamide, or docetaxel.ResultsBetween 2015–2020, we attended 26 prostate cancer patients (median age 69.5 years, range 52–84) with simultaneous oligometastases [mean 2.1 metastases, median 1.5 metastases (range 1–6)]. Eighteen patients (69%) presented lymph node metastases, 4 (15.5%) bone metastases and 4 (15.5%) both lymph node and bone metastases. With a median follow-up of 15.5 months (range 3–65 months), 16 patients (62%) are alive and tumor free while 10 (38%) are alive with tumor. Four patients (17%) developed tumor progression, out of irradiated area in all cases, with a median time to progression of 43.5 months (range 27–56 months). Actuarial progression-free survival (PFS) rates at 12 and 24 months were 94.1% and 84.7%, respectively. No grade > 2 acute or late complications were recorded.ConclusionsSimultaneous directed radical hypofractionated radiation therapy for prostate and metastases is feasible, well tolerated and achieves an acceptable PFS rate. However, further studies with longer follow-up are necessary to definitively address these observations.  相似文献   

16.
PurposeTo evaluate the planning feasibility of dose-escalated total marrow irradiation (TMI) with simultaneous integrated boost (SIB) to the active bone marrow (ABM) using volumetric modulated arc therapy (VMAT), and to assess the impact of using planning organs at risk (OAR) volumes (PRV) accounting for breathing motion in the optimization.MethodsFive patients underwent whole-body CT and thoraco-abdominal 4DCT. A planning target volume (PTV) including all bones and ABM was contoured on each whole-body CT. PRV of selected OAR (liver, heart, kidneys, lungs, spleen, stomach) were determined with 4DCT. Planning consisted of 9–10 full 6 MV photon VMAT arcs. Four plans were created for each patient with 12 Gy prescribed to the PTV, with or without an additional 4 Gy SIB to the ABM. Planning dose constraints were set on the OAR or on the PRV. Planning objective was a PTV Dmean < 110% of the prescribed dose, a PTV V110% < 50%, and OAR Dmean ≤ 50–60%.ResultsPTV Dmean < 110% was accomplished for most plans (n = 18/20), while all achieved V110%<50%. SIB plans succeeded to optimally cover the boost volume (median ABM Dmean = 16.3 Gy) and resulted in similar OAR sparing compared to plans without SIB (median OAR Dmean = 40–54% of the ABM prescribed dose). No statistically significant differences between plans optimized with constraints on OAR or PRV were found.ConclusionsAdding a 4 Gy SIB to the ABM for TMI is feasible with VMAT technique, and results in OAR sparing similar to plans without SIB. Setting dose constraints on PRV does not impair PTV dosimetric parameters.  相似文献   

17.
BackgroundThe aim of the study was to evaluate analysis criteria for the identification of the presence of rectal gas during volumetric modulated arc therapy (VMAT) for prostate cancer patients by using electronic portal imaging device (EPID)-based in vivo dosimetry (IVD).Materials and methodsAll measurements were performed by determining the cumulative EPID images in an integrated acquisition mode and analyzed using PerFRACTION commercial software. Systematic setup errors were simulated by moving the anthropomorphic phantom in each translational and rotational direction. The inhomogeneity regions were also simulated by the I’mRT phantom attached to the Quasar phantom. The presence of small and large air cavities (12 and 48 cm3) was controlled by moving the Quasar phantom in several timings during VMAT. Sixteen prostate cancer patients received EPID-based IVD during VMAT.ResultsIn the phantom study, no systematic setup error was detected in the range that can happen in clinical (< 5-mm and < 3 degree). The pass rate of 2% dose difference (DD2%) in small and large air cavities was 98.74% and 79.05%, respectively, in the appearance of the air cavity after irradiation three quarter times. In the clinical study, some fractions caused a sharp decline in the DD2% pass rate. The proportion for DD2% < 90% was 13.4% of all fractions. Rectal gas was confirmed in 11.0% of fractions by acquiring kilo-voltage X-ray images after the treatment.ConclusionsOur results suggest that analysis criteria of 2% dose difference in EPID-based IVD was a suitable method for identification of rectal gas during VMAT for prostate cancer patients.  相似文献   

18.
BackgroundThis analysis evaluates the impacts of biologically effective dose (BED) and histology on local control (LC) of spinal metastases treated with highly conformal radiotherapy to moderately-escalated doses.Materials and methodsPatients were treated at two institutions from 2010–2020. Treatments with less than 5 Gy per fraction or 8 Gy in 1 fraction were excluded. The dataset was divided into three RPA classes predictive of survival (1). The primary endpoint was LC.Results223 patients with 248 treatments met inclusion criteria. Patients had a median Karnofsky Performance Status (KPS ) of 80, and common histologies included breast (29.4%), non-small cell lung cancer (15.7%), and prostate (13.3%). A median 24 Gy was delivered in 3 fractions (BED: 38.4 Gy) to a median planning target volume (PTV) of 37.3 cc. 2-year LC was 75.7%, and 2-year OS was 42.1%. Increased BED was predictive of improved LC for primary prostate cancer (HR = 0.85, 95% CI: 0.74–0.99). Patients with favorable survival (RPA class 1) had improved LC with BED ≥ 40 Gy (p = 0.05), unlike the intermediate and poor survival groups. No grade 3–5 toxicities were reported.ConclusionsModerately-escalated treatments were efficacious and well-tolerated. BED ≥ 40 Gy may improve LC, particularly for prostate cancer and patients with favorable survival.  相似文献   

19.
BackgroundSalvage re-irradiation in patients affected by radiorecurrent prostate cancer might be a valid as well as challenging treatment option. The aim of this study was to evaluate feasibility and toxicity of salvage external beam radiotherapy (EBRT) re-treatment in patients affected by radiorecurrent prostate cancer within the prostate gland or the prostate bed.Materials and Methods15 patients underwent EBRT re-treatment using helical tomotherapy (HT), with daily Megavolt computed tomography image-guidance. We registered toxicity according to Common Terminology Criteria for Adverse Events (CTCAE) v4.0. Biochemical relapse was defined as a PSA increase > 20% compared with the pre-EBRT re-treatment value. Survival curves were calculated using the Kaplan-Meier method.ResultsAll patients received a total dose of 50 Gy (25 × 2 Gy), and 7 (46.6%) had concomitant androgen deprivation therapy (median duration of 12 months). With a median follow-up of 40.9 months, the 2-year and 4-year biochemical relapse-free survival were 55% and 35%, respectively. Acute and late genito-urinary (GU) toxicity ≥2 were recorded in 4 (26.6%) and 5 (33.3%) patients, respectively, and the 4-year late GU toxicity was 30%. Acute gastrointestinal toxicity ≥2 was recorded in 2 (13.3%) cases, whereas no patient experienced late toxicity.ConclusionsDespite the inherent bias of a retrospective analysis, our long-term results showed a low toxicity profile with a relatively low rate of biochemical control for HT re-treatment in patients affected by local radiorecurrent prostate cancer. Prospective trials are needed to investigate the role of EBRT in this setting.  相似文献   

20.
PurposeRadiation treatment planning inherently involves multiple conflicting planning goals, which makes it a suitable application for multicriteria optimization (MCO). This study investigates a MCO algorithm for VMAT planning (VMAT–MCO) for prostate cancer treatments including pelvic lymph nodes and uses standard inverse VMAT optimization (sVMAT) and Tomotherapy planning as benchmarks.MethodsFor each of ten prostate cancer patients, a two stage plan was generated, consisting of a stage 1 plan delivering 22 Gy to the prostate, and a stage 2 plan delivering 50.4 Gy to the lymph nodes and 56 Gy to the prostate with a simultaneous integrated boost. The single plans were generated by three planning techniques (VMAT–MCO, sVMAT, Tomotherapy) and subsequently compared with respect to plan quality and planning time efficiency.ResultsPlan quality was similar for all techniques, but sVMAT showed slightly better rectum (on average Dmean −7%) and bowel sparing (Dmean −17%) compared to VMAT–MCO in the whole pelvic treatments. Tomotherapy plans exhibited higher bladder dose (Dmean +42%) in stage 1 and lower rectum dose (Dmean −6%) in stage 2 than VMAT–MCO. Compared to manual planning, the planning time with MCO was reduced up to 12 and 38 min for stage 1 and 2 plans, respectively.ConclusionMCO can generate highly conformal prostate VMAT plans with minimal workload in the settings of prostate-only treatments and prostate plus lymph nodes irradiation. In the whole pelvic plan manual VMAT optimization led to slightly improved OAR sparing over VMAT–MCO, whereas for the primary prostate treatment plan quality was equal.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号