首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Richard A. Mathies (Fig. 1) is a professor of chemistry at the University of California (UC) at Berkeley. His early work at UC was on the use of resonance Raman and time-resolved optical spectroscopy to elucidate the structure and reaction dynamics of energy and information-transducing photoactive proteins called rhodopsins. His work on the Human Genome Project led to the development of high-throughput platform technologies including capillary array electrophoresis and energy transfer fluorescent dye labels for DNA sequencing and analysis. He has also pioneered the development of microfabricated capillary electrophoresis devices, capillary array electrophoresis microplates and microfabriated integrated sample preparation and detection methods. He is the co-founder of the Center for Analytical Biotechnology at UC Berkeley. Mathies was interviewed at the BIOMEMS and Biomedical Nanotechnology conference in Columbus, Ohio, 21-25 September 2001, where he gave a talk about capillary array electrophoresis-based microprocessors. Such devices could be used as point-of-care clinical and genetic analyzers, in integrated microfluidic sequencing chips and in DNA-based computing.  相似文献   

2.
Biotechnology at low Reynolds numbers.   总被引:12,自引:1,他引:11       下载免费PDF全文
The shrinking of liquid handling systems to the micron and submicron size range entails moving into the area of small Reynolds numbers. The fluid dynamics in this regime are very different from the macroscale. We present an intuitive explanation of how the different physics of small Reynolds numbers flow, along with microscopic sizes, can influence device design, and give examples from our own work using fluid flow in microfabricated devices designed for biological processing.  相似文献   

3.
Nowadays numerous microfluidic systems are being developed to address a variety of clinical problems. Latest advances in microfluidic technology are promising to revolutionize the detection of pathogens in vivo through the development of integrated lab-on-chip devices. Such microfabricated systems will undertake all steps in sample analysis from collection and preparation to molecular detection. Micro total analysis systems are suitable candidates for point of care diagnostics due to small size, low cost production and enabled portability. The work here presented aimed the use of microfluidic platforms to identify and manipulate bovine red blood cells infected by the protozoan parasite Babesia bovis. A microfabricated device based on impedance spectroscopy was used for single cell discrimination and its sensitivity and applicability as a diagnostic method for bovine babesiosis was studied. Furthermore, manipulation and sorting of normal and infected red blood cells was performed on a dielectrophoresis based microfabricated cell cytometer. Single cell analysis of normal and B. bovis infected red blood cells was performed by electrorotation and dielectric parameters such as permittivities and conductivities of the cellular membrane and cytoplasm were determined.  相似文献   

4.
We have microfabricated a flow-through biochip for the analysis of single base mutations in genomic DNA using two different materials: (1) a polycarbonate (PC) chip for performing a primary polymerase chain reaction (PCR) followed by an allele-specific ligation detection reaction (LDR) and (2) a poly(methyl methacrylate) (PMMA) chip for the detection of the LDR products using a universal array platform. The operation of the device was demonstrated by detecting low-abundant DNA mutations in gene fragments (K-ras) that carry point mutations with high diagnostic value for colorectal cancers. The PC microchip was used for sequential PCR/LDR in a continuous-flow format, in which the following three steps were carried out: (1) exponential amplification of gene fragments from genomic DNA; (2) mixing of the resultant PCR product with a LDR mixture via a Y-shaped passive micromixer and (3) ligation of two primers only when the particular mutation was present in the genomic DNA. A PMMA chip was employed as the microarray device, where zip code sequences (24-mer), which were complementary to sequences present on the discriminating primer, were micro-printed into fluidic channels embossed into the PMMA substrate. We successfully demonstrate the ability to detect one mutant DNA in 80 normal sequences with the integrated microfluidic device. The PCR/LDR/hybridization assay using the microchips performed the entire assay at a relatively fast processing speed: 18.7 min for PCR, 8.1 min for LDR, 5 min for hybridization, 10 min for washing and 2.6 min for fluorescence scanning (total processing time=ca. 50 min) with an order of magnitude reduction in reagents compared to bench-top formats.  相似文献   

5.
An innovative microfluidic platform for magnetic beads manipulation is introduced, consisting of novel microfabricated 3D magnetic devices positioned in a microfluidic chamber. Each magnetic device comprises of an embedded actuation micro-coil in various design versions, a ferromagnetic pillar, a magnetic backside plate and a sensing micro-coil. The various designs of the micro-coils enable efficient magnetic beads trapping and concentration in different patterns. The finite element analysis (FEA) results show a significant increase of the developed force on suspended magnetic beads when the magnetic pillar and backside plate were integrated into the device structure. These simulation results were confirmed experimentally by measuring the magnetic beads trapping ratios for the different designs and structures of the devices under continuous flow conditions. The trapping ratios and profiles were studied using beads counting, measuring the change of inductance with the sensing micro-coil and by image processing. The devices have efficiently demonstrated a controlled and localized magnetic beads trapping and concentration at small spatial locations for the first time. The new results shown in this study demonstrate the feasibility of efficiently using these original devices as key elements in complex bio-analysis systems.  相似文献   

6.
A major advantage of microfluidic devices is the ability to manipulate small sample volumes, thus reducing reagent waste and preserving precious sample. However, to achieve robust sample manipulation it is necessary to address device integration with the macroscale environment. To realize repeatable, sensitive particle separation with microfluidic devices, this protocol presents a complete automated and integrated microfluidic platform that enables precise processing of 0.15–1.5 ml samples using microfluidic devices. Important aspects of this system include modular device layout and robust fixtures resulting in reliable and flexible world to chip connections, and fully-automated fluid handling which accomplishes closed-loop sample collection, system cleaning and priming steps to ensure repeatable operation. Different microfluidic devices can be used interchangeably with this architecture. Here we incorporate an acoustofluidic device, detail its characterization, performance optimization, and demonstrate its use for size-separation of biological samples. By using real-time feedback during separation experiments, sample collection is optimized to conserve and concentrate sample. Although requiring the integration of multiple pieces of equipment, advantages of this architecture include the ability to process unknown samples with no additional system optimization, ease of device replacement, and precise, robust sample processing.  相似文献   

7.
Next-generation sequencing (NGS) is emerging as a powerful tool for elucidating genetic information for a wide range of applications. Unfortunately, the surging popularity of NGS has not yet been accompanied by an improvement in automated techniques for preparing formatted sequencing libraries. To address this challenge, we have developed a prototype microfluidic system for preparing sequencer-ready DNA libraries for analysis by Illumina sequencing. Our system combines droplet-based digital microfluidic (DMF) sample handling with peripheral modules to create a fully-integrated, sample-in library-out platform. In this report, we use our automated system to prepare NGS libraries from samples of human and bacterial genomic DNA. E. coli libraries prepared on-device from 5 ng of total DNA yielded excellent sequence coverage over the entire bacterial genome, with >99% alignment to the reference genome, even genome coverage, and good quality scores. Furthermore, we produced a de novo assembly on a previously unsequenced multi-drug resistant Klebsiella pneumoniae strain BAA-2146 (KpnNDM). The new method described here is fast, robust, scalable, and automated. Our device for library preparation will assist in the integration of NGS technology into a wide variety of laboratories, including small research laboratories and clinical laboratories.  相似文献   

8.
We have developed a microfluidic platform modeled after the physiologic microcirculation for multiplexed tissue-like culture and high-throughput analysis. Each microfabricated culture unit consisted of three functional components: a 50 microm wide cell culture pocket, an artificial endothelial barrier with 2 microm pores, and a nutrient transport channel. This configuration enabled a high density of cancer cells to be maintained for over 1 week in a solid tumor-like morphology when fed with continuous flow. The microfluidic chip contained 16 parallel units for "flow cell" based experiments where live cells were exposed to a soluble factor and analyzed via fluorescence microscopy or flow-through biochemistry. Each fluidically independent tissue unit contained approximately 500 cells fed with a continuous flow of 10 nL/min. As a demonstration, the toxicity profile of the anti-cancer drug paclitaxel was collected on HeLa cells cultured in the microfluidic format and compared with a 384-well dish for up to 5 days of continuous drug exposure.  相似文献   

9.
We present a double transposition technique that inserts two different transposons into target DNA to act as priming sites for amplifying the region between the two transposons for sequencing applications. Unlike some current sequencing approaches, the genome of the unknown target remains intact in this method. The transposition reaction, DNA repair, and subsequent sequencing were performed entirely in vitro, without the need for transformation into bacteria, and resulted in sequence homology with the plasmid DNA target. This approach can reduce the time required for the assay by more than a day compared with standard techniques and reduces the number of required enzymatic steps. In addition, the in vitro method enables transposition to be carried out in automated microfluidic platforms without the need for significant sample manipulation. As a demonstration of incorporating transposition techniques into high-throughput technologies, single transposition reactions were carried out in picoliter-sized droplets generated on a microfluidic platform.  相似文献   

10.
Microchip electrophoresis: a method for high-speed SNP detection   总被引:2,自引:1,他引:2  
As a trial practical application, we have applied optimized microfabricated electrophoresis devices, combined with enzymatic mutation detection methods, to the determination of single nucleotide polymorphism (SNP) sites in the p53 suppressor gene. Using clinical samples, we have achieved robust assays with quality factors as good as conventional electrophoresis in ~100 s. This is 10 and 50 times faster than capillary and slab gel electrophoresis, respectively. The method was highly accurate with an average error of mutation site measurement of only ±5 bp. No clean-up of the digestion mixtures was needed prior to injection. This greatly simplifies sample handling relative to capillary instruments, which is important for high-throughput screening applications. Following identification, absolute mutation determination of the screened samples was achieved in a second microdevice optimized for four-color DNA sequencing. Total run time was 25 min in this second device and sequencing data were in full agreement with ABI Prism® 377 sequencing runs which required 3.5 h. The tandem application of microdevices for location then full characterization of SNPs appears to confirm many of the improvements claimed for future application of microdevices in practical scaled screening for mutational analysis.  相似文献   

11.
A new generation of high-throughput technologies for quantitative and clonal analysis of adaptive immune responses have been developed. Functional analysis of lymphocyte populations has been accomplished via microfluidic assay systems. Additionally, lymphocyte receptor repertoires have been characterized on proteomic and genomic levels with multiplexed protein microarrays and high-throughput DNA sequencing. These tools are providing an unprecedented level of information depth on the distribution of adaptive immune cell (B and T cell) functionalities and repertoires, which develop upon activation following vaccination, pathogenic infection, or in disease states. These various high-throughput technologies have unlocked the potential to transform immunology into an information-rich science that will enable rapid expansion of the field of experimental systems immunology.  相似文献   

12.
A nanoliter-scale nucleic acid processor with parallel architecture   总被引:6,自引:0,他引:6  
The purification of nucleic acids from microbial and mammalian cells is a crucial step in many biological and medical applications. We have developed microfluidic chips for automated nucleic acid purification from small numbers of bacterial or mammalian cells. All processes, such as cell isolation, cell lysis, DNA or mRNA purification, and recovery, were carried out on a single microfluidic chip in nanoliter volumes without any pre- or postsample treatment. Measurable amounts of mRNA were extracted in an automated fashion from as little as a single mammalian cell and recovered from the chip. These microfluidic chips are capable of processing different samples in parallel, thereby illustrating how highly parallel microfluidic architectures can be constructed to perform integrated batch-processing functionalities for biological and medical applications.  相似文献   

13.
14.
Microscale techniques have been applied to biological assays for nearly two decades, but haven't been widely integrated as common tools in biological laboratories. The significant differences between several physical phenomena at the microscale versus the macroscale have been exploited to provide a variety of new types of assays (such as gradient production or spatial cell patterning). However, the use of these devices by biologists seems to be limited by issues regarding biological validation, ease of use, and the limited available readouts for assays done using microtechnology. Critical validation work has been done recently that highlights the current challenges for microfluidic methods and suggest ways in which future devices might be improved to better integrate with biological assays. With more validation and improved designs, microscale techniques hold immense promise as a platform to study aspects of cell biology that are not possible using current macroscale techniques.  相似文献   

15.
Molecular diagnostics can offer early detection of disease, improved diagnostic accuracy, and qualified follow-up. Moreover, the use of microfluidic devices can in principle render these analyses quickly and user-friendly, placing them within the reach of the general practitioner and maybe even in households. However, the progress launching such devices has been limited so far. We propose that an important limiting factor has been the difficulty of establishing molecular assays suitable for microfabricated formats. The assays should be capable of monitoring a wide range of molecules, including genomic DNA, RNA and proteins with secondary modifications and interaction partners, and they must exhibit excellent sensitivity and specificity. We discuss these problems and describe a series of molecular tools that may present new opportunities for lab-on-a-chip devices at the point-of-care.  相似文献   

16.
Low throughput is an inherent problem associated with most single-molecule biophysical techniques. We have developed a versatile tool for high-throughput analysis of DNA and DNA-binding molecules by combining microfluidic and dense DNA arrays. We use an easy-to-process microfluidic flow channel system in which dense DNA arrays are prepared for simultaneous imaging of large amounts of DNA molecules with single-molecule resolution. The Y-shaped microfluidic design, where the two inlet channels can be controlled separately and precisely, enables the creation of a concentration gradient across the microfluidic channel as well as rapid and repeated addition and removal of substances from the measurement region. A DNA array stained with the fluorescent DNA-binding dye YOYO-1 in a gradient manner illustrates the method and serves as a proof of concept. We have applied the method to studies of the repair protein Rad51 and could directly probe the concentration-dependent DNA-binding behavior of human Rad51 (HsRad51). In the low-concentration regime used (100 nM HsRad51 and below), we detected binding to double-stranded DNA (dsDNA) without positive cooperativity.  相似文献   

17.
The use of microfabricated microfluidic devices offers significant advantages over current technologies including fast analysis time and small reagent requirements. In the context of proteomic research, the possibility of using affinity-based separations for prefractionation of samples using microfluidic devices has significant potential. We demonstrate the use of microscale devices to achieve affinity separations of proteins using a device fabricated from borosilicate glass wafers. Photolithography and wet etching are used to pattern individual glass wafers and the wafers are fusion bonded at 650°C to obtain enclosed channels. A polymer has been successfully polymerizedin situ and used either as a frit for packing beads or, when derivatized with Cibacron Blue 3GA, as a separation matrix. Both of these technologies are based onin situ UV photopolymerization of glycidyl methacrylate (GMA) and trimethylolpropane trimethacrylate (TRIM) in channels.  相似文献   

18.
Microfluidic cell culture devices have been used for drug development, chemical analysis, and environmental pollutant detection. Because of the decreased fluid volume and increased surface area to volume ratio, interactions between device surfaces and the fluid is a key element that affects the performance and detection accuracy of microfluidic devices, particularly if fluid is recirculated by a peristaltic pump. However, this issue has not been studied in detail in a microfluidic cell culture environment. In this study, chemical loss and contaminant leakage from various polymer surfaces in a microfluidic setup were characterized. The effects of hydrophilic coating with Poly (vinyl alcohol), Pluronic® F‐68, and multi‐layer ionic coating were measured. We observed significant surface adsorption of estradiol, doxorubicin, and verapamil with PharMed® BPT tubing, whereas PTFE/BPT and stainless steel/BPT hybrid tubing caused less chemical loss in proportion to the fraction of BPT tubing in the hybrid system. Contaminants leaching out of the BPT tubing were found to be estrogen receptor agonists as determined by estrogen‐induced green fluorescence expression in an estrogen responsive Ishikawa cell line and also caused interference with an estradiol enzyme‐linked immunosorbent assay (ELISA) assay. Stainless steel/BPT hybrid tubing caused the least interference with ELISA. In summary, polymer surface and chemical interactions inside microfluidic systems should not be neglected and require careful investigations when results from a microfluidic system are compared with results from a macroscale cell culture setup. © 2009 American Institute of Chemical Engineers Biotechnol. Prog., 2009  相似文献   

19.
Sanger, or dideoxynucleotide sequencing, is an important tool for biomolecular research. An important trend in DNA sequencing is to find new and innovative ways to provide high-quality, reliable sequences in a more efficient manner, using automated capillary electrophoresis. The Apollo100 combines Sanger cycle sequencing and solid-phase reversible immobilization for product purification in a single instrument with robotic liquid handling and microfluidic (Microscale On-chip Valve) chips that have onboard thermal cycling and pneumatic mixing. Experiments were performed to determine how the DNA sequencing results from the Apollo100 compared with conventional, manual methods used in a core facility setting. Through rigorous experimentation of multiple baseline runs and a dilution series of template concentration, the Apollo100 generated sequencing that exceeded 900 bases with a quality score of 20 or above. When comparing actual client samples of amplicons, plasmids, and cosmids, Apollo100 sequencing results did not differ significantly from those reactions prepared manually. In addition, bacterial genomic DNA was sequenced successfully, directly with the Apollo100, although results were of lower quality than the standard manual method. As a result of the microscale capabilities, the Apollo100 offers valuable savings with respect to the quantity of reagents consumed compared with current manual sequencing methods, thereby continuing the demand for smaller template and reagent requirements. In conclusion, the Apollo100 can generate high-quality DNA sequences for common templates equivalent to those produced using manual sequencing methods and increases efficiency through reduced labor and reagents.  相似文献   

20.
A label-free method for DNA sequencing based on the principle of the Millikan oil drop experiment was developed. This sequencing-by-synthesis approach sensed increases in bead charge as nucleotides were added by a polymerase to DNA templates attached to beads. The balance between an electrical force, which was dependent on the number of nucleotide charges on a bead, and opposing hydrodynamic drag and restoring tether forces resulted in a bead velocity that was a function of the number of nucleotides attached to the bead. The velocity of beads tethered via a polymer to a microfluidic channel and subjected to an oscillating electric field was measured using dark-field microscopy and used to determine how many nucleotides were incorporated during each sequencing-by-synthesis cycle. Increases in bead velocity of approximately 1% were reliably detected during DNA polymerization, allowing for sequencing of short DNA templates. The method could lead to a low-cost, high-throughput sequencing platform that could enable routine sequencing in medical applications.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号