首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The aim of this study is to investigate complexation of metallothionein (MT) with cadmium and zinc ions. An oligopeptide (i.e. Lys-Cys-Thr-Cys-Cys-Ala), a fragment of MT was covalently immobilized onto piezoelectric crystals, which were first treated with ethylene diamine plasma in a glow-discharge apparatus, and then were chemically reacted with glutaraldehyde. Complexation of the immobilized MT with Zn(II) and Cd(II) ions in aqueous media was followed by recording the changes of the frequency shifts of the piezoelectric quartz crystals. The amount of Cd(II) ions interacted with the immobilized MT molecules was the highest at pH 7.4, and decreased with an increase in the pH of the medium, in parallel to the decrease in the amount of immobilized MT. The number of Zn(II) ions interacted with the immobilized MT molecules was higher than the number of Cd(II) ions when the adsorption was from solutions containing a single-metal ion with the same ion concentrations. In consecutive adsorption studies, we observed that the type of metal ions used in the first interaction is important. These experiments showed also that there is an exchange between the metal ions, and competition provokes adsorption of both ions due to synergistic-antagonistic effects.  相似文献   

2.
Yin J  Wei W  Liu X  Kong B  Wu L  Gong S 《Analytical biochemistry》2007,360(1):99-104
A biosensor based on bovine serum albumin (BSA) for the detection of lead (Pb(2+)) ion was developed and characterized. BSA was immobilized onto a colloidal Au-modified piezoelectric quartz crystal (PQC) as a biosensor for the detection of Pb(2+) ion by piezoelectric quartz crystal impedance (PQCI). Calibration curves for the quantification of Pb(2+) ion showed excellent linearity throughout the concentration range from 1.0 x 10(-7) to 3.0 x 10(-9)mol/L. The interaction between the Pb(2+) ions and the sensor chip is influenced significantly by the pH of the reaction buffer, and the optimal pH for the experiment was 5.4. Under the optimal conditions, the detection limit of 1.0 x 10(-9)mol/L for Pb(2+) was obtained. Kinetic parameters of the Pb(2+)-BSA interactions were also determined by using this chip. The sensor chip could be regenerated for use by dipping in the ethylenediaminetetraacetic acid (EDTA) solution for approximately 2h, and the chip was used to detect Pb(2+) ion for eight times without obvious signal attenuation.  相似文献   

3.
The paper describes a novel conductometric biosensor sensitive to cadmium ions based on alkaline phosphatase immobilized on gold planar microelectrodes used as transducers. Assays have been carried out with paranitrophenyl phosphate as substrate for the immobilized enzyme. Various parameters such as reticulation time, along with pH, ionic strength and buffer concentration of the measuring solution were studied. The optimized biosensor was stable, reproducible and it exhibited a detection limit of 4.45 microM for cadmium ions.  相似文献   

4.
Pyridoxal kinase (PK) is an important enzyme involved in bioactivation of vitamin B(6). Binding of PK with its substrate is the prerequisite step for the subsequent catalytic phosphorylation of the substrate. In the present study, a surface plasmon resonance biosensor (BIAcore) was employed to characterize the binding interaction between wild-type porcine PK and an immobilized substrate, pyridoxamine. Pyridoxamine was modified with 11-mercaptoundecanic acid and immobilized on a sensor chip through the formation of a self-assembled monolayer. The binding of PK to the immobilized pyridoxamine was followed in real time and the kinetic parameters were derived from non-linear analysis of the sensorgram. The effects of buffer pH, monovalent cations (Na(+), K(+)) and divalent cations (Mn(2+), Zn(2+), Mg(2+)) on the binding kinetics were determined. Optimal pH for PK-pyridoxamine interaction in the absence of divalent ions is at around 7.4. While K(+) increased and Na(+) decreased the binding affinity (K(A)) of PK to immobilized pyridoxamine, all divalent cations increased the K(A) of PK for pyridoxamine. Solution phase affinity measurement based on a competitive binding assay was used to determine the affinities of PK for different vitamin B(6) analogues. The order of affinity of PK for different analogues is: pyridoxal-oxime>pyridoxine>pyridoxamine>pyridoxal>pyridoxal phosphate. This is the first study to demonstrate that buffer conditions such as pH and concentration of monovalent and/or divalent ions can directly alter the binding of PK for its substrates. The quantitative kinetic and thermodynamic parameters obtained by SPR measurement provide the insight information into the catalytic activity of this enzyme.  相似文献   

5.
A potentiometric enzyme electrode for the direct measurement of organophosphate (OP) nerve agents was developed. The basic element of this enzyme electrode was a pH electrode modified with an immobilized organophosphorus hydrolase (OPH) layer formed by cross-linking OPH with bovine serum albumin (BSA) and glutaradehyde. OPH catalyses the hydrolysis of organophosphorus pesticides to release protons, the concentration of which is proportional to the amount of hydrolysed substrate. The sensor signal and response time was optimized with respect to the buffer pH, ionic concentration of buffer, temperature, and units of OPH immobilized using paraoxon as substrate. The best sensitivity and response time were obtained using a sensor constructed with 500 IU of OPH and operating in pH 8.5, 1 mM HEPES buffer. Using these conditions, the biosensor was used to measure as low as 2 microM of paraoxon, ethyl parathion, methyl parathion and diazinon. The biosensor was completely stable for at least one month when stored in pH 8.5, 1 mM HEPES + 100 mM NaCl buffer at 4 degrees C.  相似文献   

6.
In this paper, heavy metal biosensor based on immobilization of metallothionein (MT) to the surface of carbon paste electrode (CPE) via anti-MT-antibodies is reported. First, the evaluation of MT electroactivity was done. The attention was focused on the capturing of MT to the CPE surface. Antibodies incorporated and mixed into carbon paste were stable; even after two weeks the observed changes in signal height were lower than 5%. Further, the interaction of MT with polyclonal chicken antibodies incorporated in carbon paste electrode was determined by square-wave voltammetry. In the voltammogram, two signals--labelled as cys(MT) and W(a)--were observed. The cys(MT) corresponded to -SH moieties of MT and W(a) corresponded to tryptophan residues of chicken antibodies. Time of interaction (300 s) and MT concentration (125 μg/ml) were optimized to suggest a silver(I) ions biosensor. Biosensor (CPE modified with anti-MT antibody) prepared under the optimized conditions was then used for silver(I) ions detection. The detection limit (3 S/N) for silver(I) ions was estimated as 0.5 nM. The proposed biosensor was tested by detection spiking of silver(I) ions in various water samples (from very pure distilled water to rainwater). Recoveries varied from 74 to 104%.  相似文献   

7.
Li J  Liu Y  Ru B 《Cell biology international》2005,29(10):843-848
Metallothioneins (MTs) are thought to participate in a wide variety of physiological roles, but the mechanisms involved are still unclear. The study was designed to examine the possible factors related to these mechanisms. Methods, including transfection, MTT assay and flow cytometry, were used to investigate the effect of MTs on cell viability and their interactions with cadmium and zinc in HEK293 cells. The results showed that transient overexpression of human MT1A, MT2 and MT3 genes dynamically affected cell viability, and the effect was influenced by zinc and cadmium ions. Overexpressed MTs with added zinc showed a greater inhibitory effect on cell viability. Overexpressed MTs protected cells against low concentrations of cadmium ions (10 microM), but increased cell death in response to high concentrations (20-50 microM). Out of the three MTs, MT1A was more efficient than MT2 and MT3 in its resistance to cadmium (10 microM), and MT3 together with zinc showed more cell growth inhibition than MT1 and MT2. These results indicate that both of the divalent metal ions that could bind MTs, as well as the individual MT isoforms, affect the role of MTs on cell viability, which may explain in part why the comprehensive effect of MTs on the cells was elusive.  相似文献   

8.
A method to detect metallothionein (MT) by Western blotting technique is described. Cadmium-containing rat MT-I and -II were subjected to sodium dodecylsulfate/polyacrylamide gel electrophoresis (SDS-PAGE) without prior reduction by 2-mercaptoethanol (2-ME), because prior reduction of MTs by 2-ME resulted in diffused bands. After SDS-PAGE, MTs in the gel were reduced by incubating in buffer containing 2-ME, and then electrophoretically transferred to a polyvinylidene fluoride membrane. Non-reduced MTs were not found to be immobilized on the membrane. Prior to electrophoresis the zinc, in zinc-containing MT samples, must be replaced with cadmium by addition of excess cadmium chloride. MTs immobilized on the membrane were detected by two methods, (1) binding of radioactive cadmium and (2) immunochemical staining using protein-A/colloidal gold conjugate, the detection limits of which were 0.4 and 0.06-0.16 micrograms, respectively.  相似文献   

9.
The feasibility of buffer exchange in biosensor chip mass spectrometry, along with the construction of base sensor chips and use of alternative chip chemistries, is demonstrated in this work. Beta-2-microglobulin (beta2m) was used as an analyte and captured in the first flow cell (FC1) on the sensor chip surface by an immobilized anti-beta2m antibody. Low pH buffer was then used to elute the captured analyte from the flow cell and route it to a second flow cell (FC2) downstream that served as a cation exchanger that retains the analyte. Following additional washes in FC1, the analyte present in FC2 was either eluted with a higher pH buffer (to demonstrate the possibility of elution into a downstream trypsin flow cell), or it was subjected to matrix-assisted laser desorption/ionization-time of flight (MALDI-TOF) mass spectrometry analysis to verify its presence in FC2. In a separate experiment, a gold-sputtered glass slide (base chip) was activated through a formation of 11-mercaptoundecanoic acid self-assembled monolayer and via reaction with 1,1"-carbonyldiimidazole. The activated chip was placed manually into the biosensor and two surfaces (flow cells) were derivatized with antibodies to beta2m and cystatin C (cysC). To evaluate the chip performance, diluted human urine aliquot was injected over the flow cells. Following the surface plasmon resonance analysis, the chip was MALDI-TOF MS analyzed, yielding signals from beta2m and cysC from their respective flow cells. Artifacts arising from the surface chemistries were not observed in the analysis.  相似文献   

10.
Exposure of bovine estrogen receptor to the metal chelators EDTA and 1,10-phenanthroline results in a loss of nonspecific DNA binding, presumably because of the removal of "zinc finger" zinc. Nonspecific DNA binding, as measured by a DNA-cellulose binding assay, can be restored by dialysis of the aporeceptor against buffer containing zinc, cadmium, and cobalt but not with buffer containing copper or nickel. More detailed studies were carried out using a bacterially expressed polypeptide encompassing the DNA binding domain of the human estrogen receptor. Apopolypeptide fails to bind DNA specifically, as measured by mobility shift assay using a consensus estrogen response element hexamer containing oligonucleotide, but DNA binding was restored by dialysis of the apopolypeptide against buffer containing zinc, cadmium, and cobalt but not with buffer containing copper or nickel. Dissociation constants of zinc- and cadmium-reconstituted polypeptide for the estrogen response element hexamer (66 and 48 nM, respectively) are virtually indistinguishable from native polypeptide (Kd = 48 nM) whereas cobalt-reconstituted polypeptide has a lower affinity (Kd = 720 nM). However, native, zinc-, cadmium-, and cobalt-reconstituted polypeptides gave identical results in a methylation interference assay. Competition experiments with zinc and copper or nickel suggest that copper and nickel are able to bind to zinc finger residues but do so nonproductively. The relative affinities copper greater than cadmium greater than zinc greater than cobalt greater than nickel for the polypeptide were determined by a zinc blot competition assay. The ability of cadmium and cobalt to substitute for zinc in the zinc fingers demonstrates a structural "flexibility" in the DNA binding domain as each of these metals has slightly different ionic radii. On the other hand, subtle differences in DNA binding affinity and/or specificity could exist, which may not be detectable here. Also, the ability of metals to substitute for zinc in the DNA binding domain suggests that metal substitution in these zinc fingers in vivo may be of relevance to the toxicity and/or carcinogenicity of some of these metals.  相似文献   

11.
The determination of bile acid concentration in urine is useful for the screening and diagnosis of various hepatobiliary diseases. Currently, there is no concise method to determine bile acid concentration in urine. This study describes a bile acid biosensor fabricated by electrochemical technique for urinalysis. The micro-planar electrodes employed for the study consisted of a working electrode (platinum), a counter electrode (platinum) and a reference electrode (silver/silver chloride (Ag/AgCl)). The sensor chip was coated with Nafion using a spin-coater in order to both eliminate many interference species in urine and achieve long-term stability of the reference electrode. Nafion coating allowed the sensor chip to prevent the electrode reaction from interference species in urine, because it is charged negative strongly (Nafion contains sulfonic acid group). Three enzymes (bile acid sulfate sulfatase: BSS, beta-hydroxysteroid dehydrogenase: beta-HSD, and NADH oxidase: NHO) were immobilized by glutaraldehyde (GA: cross-linker) onto the sensor chip, because the immobilization of enzymes by GA is simple and commonly carried out. The sensor chip was able to detect bile acid in buffer solution. The optimum enzyme ratio immobilized onto the sensor chip was BSS:beta-HSD:NHO=4:4:20 U/1 chip. There was a relationship between the concentration of bile acid and the response current value. The dynamic range of the sensor chip was 2-100 microM for bile acid. Additionally, bile acid in the urine specimen could be detected using this bile acid biosensor. We present a simple and rapid bile acid biosensor with high sensitivity and high reproducibility.  相似文献   

12.
Selectivity coefficients for binding of negative and positive ions to chitosans of different chemical composition have been determined by equilibrium dialysis. Chitosans with different fraction of acetylated units (FA of 0.01 and 0.49) generally behaved similarly in their selectivity towards both negative and positive ions. No selectivity was found in the binding of chloride and nitrate ions, while chitosan showed a strong selectivity towards molybdate polyoxyanions, with selectivity coefficients around 100. Chitosan showed a strong selectivity towards copper (Cu2+) compared to the metal ions zinc (Zn2+), cadmium (Cd2+) and nickel (Ni2+), with selectivity coefficients from 10 to 1000, while little or no selectivity could be detected with the other metal ions. Ionic strength and pH did not influence the selectivity coefficients of the chitosans towards the metal ions.  相似文献   

13.
The influence of dietary iron deficiency on acute nickel, lead or cadmium toxicity as reflected by the induction of hepatic, renal and intestinal metallothionein (MT), disposition of the metals, and alterations in hematological parameters was investigated in rats. The administration of cadmium induced the hepatic, renal and intestinal MT while that of nickel or lead induced hepatic MT only. However, dietary iron deficiency did not influence the cadmium induced tissue MT but enhanced the ability of nickel or lead to restore the normal synthesis of renal and intestinal MT lowered under the influence of reduced body iron status. The accumulation of lead in liver and kidney and that of cadmium enhanced in liver only, while tissue deposition of nickel remained unaffected by iron deficiency. The induction of hepatic MT by three metals appears related to the concomitant rise in the hepatic zinc, calcium and iron levels in normal rats. However, dietary iron deficiency increased the hepatic zinc in response to nickel or cadmium and that of heptic calcium in response to lead.  相似文献   

14.
A surface plasmon resonance (SPR) sensor based on DNA hybridization has been developed for the detection of Fusarium culmorum, a fungal pathogen of cereals. A 0.57 kbp DNA fragment of F. culmorum was amplified by specific primers and a 25-mer oligonucleotide probe was selected within the sequence of the PCR amplicon. After biotinilation, the probe was immobilized on a streptavidin sensor chip and tested for biospecific interaction with PCR products of F. culmorum. The effect of denaturating agents (formamide and urea) and ionic strength (NaCl) on hybridization efficiency of double-stranded PCR products with the immobilized probe and the specificity of the probe were investigated. The SPR biosensor was successfully used for the detection of F. culmorum in culture material of different strains and in naturally infected wheat samples. Tested on fungal cultures, it showed a good selectivity for F. culmorum against other species of either Fusarium or other fungal genera. A background signal was observed in wheat samples strictly depending on the DNA amount of the testing matrix. Testing 30 ng of durum wheat DNA the detection limit was 0.06 pg of F. culmorum DNA. The developed PCR-SPR assay allowed to detect F. culmorum with sensitivity and specificity higher than gel-electrophoresis analysis.  相似文献   

15.
《Inorganica chimica acta》1988,152(2):111-115
A study of the use of the metal chelation properties of Chelex-100 in metal binding reactions of metallothionein (MT), is described. The stoichiometric ratios of bound metals in MT were determined at several stages during a titration in which the Zn(II) in Zn7MT was displaced by Cd(II), by using Chelex-100 to sequester the free zinc. The stoichiometric ratios provide convincing supporting evidence that the complicated circular dichroism spectral properties observed during the titration arise because the incoming cadmium is distributed across both domains in the protein. It is shown that Chelex-100 does not sequester zinc or cadmium directly from the metallothionein binding sites. Use of Chelex-100 over the temperature range −20 to 65 °C is demonstrated. The chelation capacity of Chelex-100 (in terms of μ metal ion/mg resin) has been determined for a range of elements important in metal toxicology, including: cadmium (33 μ), zinc (22 μ), copper (19 μ), silver (38 μ), lead (40 μ) and mercury (40 μ).  相似文献   

16.
An enzymatic biosensor was fabricated by the covalent immobilization of pyruvate oxidase (PyO) onto the nano-particle comprised poly-5,2':5',2'-terthiophene-3'-carboxylic acid, poly-TTCA (nano-CP) layers on a glassy carbon electrode (GCE) for the amperometric detection of the phosphate ions. The direct electron transfer reaction of the immobilized PyO onto the nano-CP layers was investigated and the electron transfer rate constant was determined to be 0.65 s(-1). The electrochemically prepared nano-CP lowered the oxidation potential (+0.40 V versus Ag/AgCl) of an enzymatically generated H(2)O(2) by PyO in a phosphate solution. Experimental parameters affecting the sensitivity of the biosensors, such as amounts of the cofactors, the pH, the applied potential, and the temperature were optimized. A linear response for the detection of the phosphate ion was observed between 1.0 microM and 100 microM and the detection limit was determined to be about 0.3 microM. The response time of the biosensors was about 6s. The biosensor showed good selectivity towards other interfering anions. The long-term storage stability of the phosphate biosensor was studied and the sensor was applied in a human serum sample for the phosphate ions detection.  相似文献   

17.
Thirty thermophilic strains isolated from heavy metal-rich hydrothermal vent sites at Lau Basin were tested for their susceptibility to cadmium, zinc, cobalt, and nickel. The 14 aerobic spore formers belonging to the genus Bacillus, 6 anaerobic fermenters from the order Thermotogales, and 10 anaerobic sulfur reducers from the order Thermococcales could be clearly distinguished according to their metal susceptibilities. The Thermococcales were found to exhibit the highest resistance to cadmium and zinc, whereas Thermotogales were highly sensitive to these metals. In contrast, the Thermotogales displayed the highest resistance to cobalt ions. No clear distinction could be established between the metal susceptibilities of these strains and seven reference organisms used for comparative studies. Cadmium resistance, slightly inducible in some cadmium-resistant bacilli, was not plasmid mediated. The amount of cadmium immobilized by the Thermotogales was related to their level of resistance to this metal. Received: 24 February 2000 / Accepted: 28 March 2000  相似文献   

18.
The objective of this study was to convert corncobs to metal ion adsorbents for wastewater treatment. Ground corncobs were modified with either 0.6 M citric acid (CA) or 1.0 M phosphoric acid (PA) to help improve their natural adsorption capacity. The effect of a combination of wash and modification treatment was tested for corncob adsorption efficiency with five different metal ions (cadmium, copper, lead, nickel, zinc) individually or in a mixed solution containing each metal at a 20 mM concentration. Results were compared to those of commercial resins Amberlite IRC-718, Amberlite 200, Duolite GT-73 and carboxymethylcellulose (CMC). Modified corncobs showed the same adsorption efficiency as Duolite GT-73 for cadmium, copper, nickel and zinc ions and had greater adsorption than CMC for nickel and zinc ions. For mixed metals, the modified corncobs exhibited the same adsorption efficiency as Duolite GT-73 for cadmium and copper ions and the same or higher adsorption than Amberlite IRC-718 for lead ions. Adsorption capacities of modified samples were compared to those of Amberlite IRC-718, Amberlite 200 and Duolite GT-73. Commercial resins generally had higher adsorption capacities than modified corncobs. However, the adsorption capacity of modified corncobs for copper and lead ions was equivalent to Duolite GT-73, but was lower than for Amberlite IRC-718 or Amberlite 200. Depending on the specific metal ion and the presence or absence of other metal ions, chemically modified corncobs were at least equivalent in adsorption properties to all of the commercial cation exchange resins examined in this study.  相似文献   

19.
Mercury ions (Hg(2+)) are a highly toxic and ubiquitous pollutants requiring rapid and sensitive on-site detection methods in the environment and foods. Herein, we report an envanescent wave DNA-based biosensor for rapid and very sensitive Hg(2+) detection based on a direct structure-competitive detection mode. In this system, a DNA probe covalently immobilized onto a fiber optic sensor contains a short common oligonucleotide sequences that can hybidize with a fluorescently labeled complementary DNA. The DNA probe also comprises a sequence of T-T mismatch pairs that binds with Hg(2+) to form a T-Hg(2+)-T complex by folding of the DNA segments into a hairpin structure. With a structure-competitive mode, a higher concentration of Hg(2+) leads to less fluorescence-labeled cDNA bound to the sensor surface and thus to lower fluorescence signal. The total analysis time for a single sample, including the measurement and surface regeneration, was under 6 min with a Hg(2+) detection limit of 2.1 nM. The high specificity of the sensor was demonstrated by evaluating its response to a number of potentially interfering metal ions. The sensor's surface can be regenerated with a 0.5% SDS solution (pH 1.9) over 100 times with no significant deterioration of performance. This platform is potentially applicable to detect other heavy metal ions or small-molecule analytes for which DNA/aptamers can be used as specific sensing probes.  相似文献   

20.
生物传感芯片是一类综合了生物芯片和生物传感器的优点的新型生物芯片,在保持传统生物芯片的高通量、可寻址、并行处理等特点的基础上,与生物传感器技术相结合,进一步提高了芯片检测的灵敏度和特异性。常见的生物传感芯片主要有光纤传感芯片、表面等离子体共振传感芯片、热生物传感芯片、压电晶体传感芯片等,可用于各种生物大分子,如蛋白质、核酸等的检测,金属离子的测定,病原体的检测,药物筛选等。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏