首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
An overview is presented of gas chromatography/mass spectrometry (GC/MS) and liquid chromatography/mass spectrometry (LC/MS), the two major hyphenated techniques employed in metabolic profiling that complement direct 'fingerprinting' methods such as atmospheric pressure ionization (API) quadrupole time-of-flight MS, API Fourier transform MS, and NMR. In GC/MS, the analytes are normally derivatized prior to analysis in order to reduce their polarity and facilitate chromatographic separation. The electron ionization mass spectra obtained are reproducible and suitable for library matching, mass spectral collections being readily available. In LC/MS, derivatization and library matching are at an early stage of development and mini-reviews are provided. Chemical derivatization can dramatically increase the sensitivity and specificity of LC/MS methods for less polar compounds and provides additional structural information. The potential of derivatization for metabolic profiling in LC/MS is demonstrated by the enhanced analysis of plant extracts, including the potential to measure volatile acids such as formic acid, difficult to achieve by GC/MS. The important role of mass spectral library creation and usage in these techniques is discussed and illustrated by examples.  相似文献   

2.
Liquid chromatography-mass spectrometry (LC-MS) using atmospheric pressure ionization is drastically different from hitherto available analytical methods used to detect polar analytes. The electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) sources of MS have contributed to the advancement of LC-MS and LC-MS/MS techniques for the analysis of biological samples. However, one major obstacle is the weak ionization of some analytes in the ESI and APCI techniques. In this review, we introduce high-sensitivity methods using several derivatization reagents for ionization enhancement. We also present an overview of chemical derivatization methods that have been applied to small molecules, such as amino acids and steroids, in biological samples.  相似文献   

3.
S J Gaskell 《Steroids》1990,55(10):458-462
Fast atom bombardment/mass spectrometry or liquid secondary ion mass spectrometry provides the capability for direct analysis of steroid conjugates (sulfates, glucuronides) without prior hydrolysis or derivatization. During the analysis of biologic extracts, limitations on the sensitivity of detection arise from the presence of co-extracted material which may suppress or obscure the analyte signal. A procedure is described for the quantitative determination of dehydroepiandrosterone sulfate in serum which achieved selective isolation of the analyte using immunoadsorption extraction and highly specific detection using tandem mass spectrometry. A stable isotope-labeled analog [( 2H2]dehydroepiandrosterone sulfate) was used as internal standard. Fast atom bombardment of dehydroepiandrosterone sulfate yielded abundant [M-H]- ions that fragmented following collisional activation to give HSO4-; m/z 97. During fast atom bombardment/tandem mass spectrometry of serum extracts, a scan of precursor ions fragmenting to give m/z 97 detected dehydroepiandrosterone sulfate and the [2H2]-labeled analog with a selectivity markedly superior to that observed using conventional mass spectrometry detection. Satisfactory agreement was observed between quantitative data obtained in this way and data obtained by gas chromatography/mass spectrometry of the heptafluorobutyrates of dehydroepiandrosterone sulfate and [2H2]dehydroepiandrosterone sulfate obtained by direct derivatization.  相似文献   

4.
A comparison of the analytical performance of atmospheric pressure chemical ionization (APCI) and electrospray ionization (ESI) for the quantitative determination of six urinary phytoestrogens (daidzein, O-desmethylangolensin, equol, enterodiol, enterolactone and genistein) by high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) is presented here. Both APCI and ESI were suitable for the analysis of these compounds; however, ESI did improve measurement imprecision and sensitivity in certain cases. Method imprecision (between-run coefficients of variation [CVs] from duplicate analysis of three quality control [QC] urine pools across 20 runs) was 5.6-12% for ESI, as opposed to 5.3-30% for APCI. At low concentrations (3-60 ng/mL, analyte dependent) imprecision was lower with ESI, whereas both techniques were generally commensurate at high concentrations (200-1000 ng/mL, analyte dependent). Method accuracy (spiked analyte recovery from the QC pools) was comparable between techniques: 86-114% for ESI; 95-105% for APCI. Limits of detection (LODs) were equivalent or better with ESI compared to APCI, with the most significant LOD improvement observed for equol (ESI: 0.3 ng/mL; APCI: 2.7 ng/mL). This translated into a substantial increase in equol detection frequency (% of sample results above LOD) within a random patient sample subset (98% for ESI, compared to 81% for APCI, n=378). Correlation (Pearson) and agreement (Deming regression, Bland-Altman bias) between ESI and APCI results in the patient subset was better in cases where imprecision and sensitivity was similar for both techniques (daidzein, enterolactone, genistein: r=0.993-0.998; slope=0.98-1.03; bias=-4.2 to -0.8%); correlation and/or agreement was poorer for analytes, where APCI imprecision and sensitivity were inferior (equol, O-desmethylangolensin, enterodiol). Baring significant factors arising from differences in ionization source design, these observations suggest that ESI is more appropriate for urinary biomonitoring of these compounds by LC-MS/MS.  相似文献   

5.
A liquid chromatography-mass spectrometry method is described for the determination of tetramethylpyrazine (TMP) and its active metabolite, 2-hydroxymethyl-3,5,6-trimethylpyrazine (HTMP) in dog plasma. This method involves a plasma clean-up step using protein precipitation procedure followed by LC separation and positive electrospray ionization mass spectrometry detection (ESI-MS). Chromatographic separation of the analytes was achieved on a C18 column using a mobile phase of methanol, water and acetic acid (50:50:0.6, v/v/v) at a flow rate of 1.0 ml/min. Selected ion monitoring (SIM) mode was used for analyte quantitation at m/z 137.2 for TMP, m/z 153.2 for HTMP and m/z 195.2 for caffeine. The linearity was obtained over the concentration ranges of 20-6000 ng/ml for TMP and 20-4000 ng/ml for HTMP and the lower limit of quantitation was 20 ng/ml for both analytes. For each level of QC samples, both inter- and intra-day precisions (R.S.D.) were 相似文献   

6.
A novel skin tissue extraction method coupled with liquid chromatography-tandem mass spectrometry (LC/MS/MS) detection was developed and validated for the analysis of endogenous pyrrole-2,3,5-tricarboxylic acid (PTCA), a eumelanin specific biomarker, in human skin punch biopsies. The analyte is extracted from the matrix (2 mm skin punch biopsies) using a simple oxidative degradation procedure. The extract supernatants are evaporated, reconstituted in mobile phase solvent, and injected into the LC/MS/MS system without further derivatization. The chromatographic separation is achieved on a reverse phase high performance liquid chromatography (HPLC) column. The accuracy and precision of the method was determined over the concentration range of 1-1000 ng/mL PTCA from human skin extracts in three validation batch runs. Inter-assay precision (%CV) and accuracy (%R.E.) of the quality control samples were 相似文献   

7.
Atmospheric pressure photoionization (APPI) as an interface for the high-performance liquid chromatography (HPLC)-tandem mass spectrometry (MS/MS) system was employed for the direct determination of 17alpha-ethinylestradiol (EE(2)) in the incubation mixtures to support in vitro hepatic clearance studies. For the APPI source, the radical cation of the analyte via charge exchange with the dopant radical cation was used for the detection of EE(2) in the positive ion mode. It was demonstrated that the major signals of EE(2) in the acetonitrile/water mobile phase were substantially increased by replacing toluene with anisole as the dopant. The effects of several experimental conditions on the photoionization efficiency of EE(2) in the dopant-assisted APPI source were explored. Electrospray ionization (ESI) source was also suitable for the analysis of the analyte; however, ESI required a derivatization step prior to analysis. The applicability of the proposed HPLC-APPI-MS/MS approach following a protein precipitation procedure for the determination of EE(2) at low nano-mole levels was examined with respect to assay specificity and linearity. The assay results obtained by both HPLC-APPI-MS/MS and HPLC-ESI-MS/MS methods were in good agreement.  相似文献   

8.
A specific LC-MS/MS assay was developed for the automated determination of talinolol in human plasma, using on-line solid phase extraction system (prospekt 2) combined with atmospheric pressure chemical ionization (APCI) tandem mass spectrometry. The method involved simple precipitation of plasma proteins with perchloric acid (contained propranolol) as the internal standard (IS) and injection of the supernatant onto a C8 End Capped (10 mmx2 mm) cartridge without any evaporation step. Using the back-flush mode, the analytes were transferred onto an analytical column (XTerra C18, 50 mmx4.6 mm) for chromatographic separation and mass spectrometry detection. One of the particularities of the assay is that the SPE cartridge is used as a column switching device and not as an SPE cartridge. Therefore, the same SPE cartridge could be used more than 28 times, significantly reducing the analysis cost. APCI ionization was selected to overcome any potential matrix suppression effects because the analyte and IS co-eluted. The mean precision and accuracy in the concentration range 2.5-200 ng/mL was found to be 103% and 7.4%, respectively. The data was assessed from QC samples during the validation phase of the assay. The lower limit of quantification was 2.5 ng/mL, using a 250 microL plasma aliquot. The LC-MS/MS method provided the requisite selectivity, sensitivity, robustness accuracy and precision to assess pharmacokinetics of the compound in several hundred human plasma samples.  相似文献   

9.
The simultaneous assay of cocaine, opiates and metabolites in small biological samples continues to be a difficult task. This report focuses upon tabulation of important techniques (extraction, derivatization, chromatographic conditions, detection mode, data acquisition) reported over the last decade that were used in the development of assays for these analytes. The most prevalent procedures for extraction of cocaine, opiates and metabolites were liquid—liquid and solid-phase extraction isolation methods. Following extraction analytes were derivatized and analyzed by gas chromatography—mass spectrometry. The technique most often used for chromatographic separation was fused-silica capillary column gas chromatography. Detection generally was performed by selected ion monitoring in the positive-ion electron-impact ionization mode, although full-scan acquisition and positive- and negative-ion chemical ionization methods have been used. It was apparent from the review that there is a continuing need for greater sensitivity and selectivity in the assay of highly potent opiates and for cocaine and metabolites.  相似文献   

10.
Sulfonyl chlorides substituted with functional groups having high proton affinity can serve as derivatization reagents to enhance the sensitivity for steroidal estrogens in liquid chromatography electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS). The most commonly used reagent for derivatization of estrogens for LC-ESI-MS/MS is dansyl chloride. In this study, we compared dansyl chloride, 1,2-dimethylimidazole-4-sulfonyl (DMIS) chloride, pyridine-3-sulfonyl (PS) chloride, and 4-(1H-pyrazol-1-yl)benzenesulfonyl (PBS) chloride for derivatization of 17beta-estradiol (E2) prior to LC-ESI-MS/MS. The product ion spectra of the dansyl and DMIS derivatives were dominated by ions representing derivatization reagent moieties. In contrast, the product ion spectrum of the PS derivative of E2 and, to a lesser extent, the PBS derivative, showed analyte-specific fragment ions. Derivatization with PS chloride was therefore chosen for further investigation. The product ion spectrum of the PS derivative of E2 showed intense ions at m/z 272, assigned to the radical E2 cation, and at m/z 350, attributed to the loss of SO(2) from the [M+H](+) ion. Third-stage mass spectrometry of the PS derivative of E2 with isolation and collisional activation of the m/z 272 ion resulted in steroid C and D ring cleavages analogous to those observed in electron ionization mass spectrometry. The product ion spectra of the PS derivatives of estrone, 17alpha-ethinylestradiol, equilin, and equilenin showed similar estrogen-specific ions. Using derivatization with PS chloride, we developed an LC-ESI-MS/MS method with multiple reaction monitoring of primary and confirmatory precursor-to-product ion transitions for the determination of E2 in serum.  相似文献   

11.
Column-switching techniques for high-performance liquid chromatography of two acidic drugs, ibuprofen and mefenamic acid, in human serum with short-wavelength ultraviolet detection are described. The method involved extraction of the analyte from acidified serum followed by the chromatographic analysis using column switching. Three ODS columns were used each with different mobile phase, utilizing the difference of ion-pair formation or of ionization caused by pH change. The method offered high sensitivity and selectivity, with short-wavelength ultraviolet detection at 221 nm for ibuprofen and at 219 nm for mefenamic acid. The detection limits were 0.5 ng/ml (2.4 pmol/ml) for ibuprofen and 0.1 ng/ml (0.4 pmol/ml) for mefenamic acid using 1 ml of serum, both at a signal-to-noise ratio of 3. With some modifications, the principle of the method would be applicable to other acidic compounds in biological fluids.  相似文献   

12.
Glycyrrhizin (GLY) which has been widely used in traditional Chinese medicinal preparation possesses various pharmacological effects. In order to investigate the pharmacokinetic behavior of GLY in human after oral administration of GLY or licorice root, a liquid chromatography/tandem mass spectrometry (LC-MS/MS) method was developed and validated for the simultaneous determination of GLY and its major metabolite glycyrrhetic acid (GA) in human plasma. The method involved a solid phase extraction of GLY, GA, and alpha-hederin, the internal standard (IS), from plasma with Waters Oasis MCX solid phase extraction (SPE) cartridges (30 mg) and a detection using a Micromass Quattro LC liquid chromatography/tandem mass spectrometry system with electrospray ionization source in positive ion mode. Separation of the analytes was achieved within 5min on a SepaxHP CN analytical column with a mobile phase of acetonitrile:water (50:50, v:v) containing 0.1% formic acid and 5mM ammonium acetate. Multiple reaction monitoring (MRM) was utilized for the detection monitoring 823--> 453 for GLY, 471--> 177 for GA and 752--> 456 for IS. The LC-MS/MS method was validated for specificity, sensitivity, accuracy, precision, and calibration function. The assay had a calibration range from 10 to 10,000 ng/mL and a lower limit of quantification of 10 ng/mL for both GLY and GA when 0.2 mL plasma was used for extraction. The percent coefficient of variation for accuracy and precision (inter-run and intra-run) for this method was less than 11.0% with a %Nominal ranging from 87.6 to 106.4% for GLY and 93.7 to 107.8% for GA. Stability of the analytes over sample processing (freeze/thaw, bench-top and long-term storage) and in the extracted samples was also tested and established.  相似文献   

13.
Styrene and 1,3-butadiene are important intermediates used extensively in the plastics industry. They are metabolized mainly through cytochrome P450-mediated oxidation to the corresponding epoxides, which are subsequently converted to diols by epoxide hydrolase or through spontaneous hydration. The resulting styrene glycol and 3-butene-1,2-diol have been suggested as biomarkers of exposure to styrene and 1,3-butadiene, respectively. Unfortunately, poor ionization of the diols within electrospray mass spectrometers becomes an obstacle to the detection of the two diols by liquid chromatography/electrospray ionization-mass spectrometry (LC/ESI-MS). We developed an LC/ESI-MS approach to analyze styrene glycol and 3-butene-1,2-diol by means of derivatization with 2-bromopyridine-5-boronic acid (BPBA), which not only dramatically increases the sensitivity of diol detection but also facilitates the identification of the diols. The analytical approach developed was simple, quick, and convincing without the need for complicated chemical derivatization. To evaluate the feasibility of BPBA as a derivatizing reagent of diols, we investigated the impact of diol configuration on the affinity of a selection of diols to BPBA using the established LC/ESI-MS approach. We found that both cis and trans diols can be derivatized by BPBA. In conclusion, BPBA may be used as a general derivatizing reagent for the detection of vicinal diols by LC/MS.  相似文献   

14.
Thin-layer chromatography (TLC), gas chromatography (GC), and liquid chromatography (LC) in combination with mass spectrometry (MS) have been adopted for the isolation and identification of oxolipids and for determining their functionality. TLC provides a rapid separation and access to most oxolipids as intact molecules and has recently been effectively interfaced with time-of-flight (TOF) MS (TOF-MS). GC with flame ionization (FI) (GC/FI) and electron impact (EI) MS (GC/EI-MS) has been extensively utilized in the analysis of isoprostanes and other low-molecular-weight oxolipids, although these methods require derivatization of the analytes. In contrast, LC with ultraviolet (UV) absorption (LC/UV) or evaporate light scattering detection (ELSD) (LC/ELSD) as well as electrospray ionization (ESI) or atmospheric pressure chemical ionization (APCI) MS (LC/ESI-MS) or LC/APCI-MS has proven to be well suited for the analysis of intact oxolipids and their conjugates without or with minimal derivatization. Nevertheless, kit-based colorimetric and fluorescent procedures continue to serve as sensitive indicators of the presence of hydroperoxides and aldehydes.
Arnis KuksisEmail:
  相似文献   

15.
Oligosaccharides of hydroxypropylmethyl cellulose, hydroxypropyl cellulose, and methyl cellulose were investigated by matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). The cellulose ether oligosaccharides were produced either by enzymatic depolymerization utilizing the purified family 5 endoglucanase from Bacillus agaradhaerens or by partial acidic depolymerization. To lower the limit of detection in MALDI-MS three dilakylamines, dimethyl-, diethyl-, and dipropylamine were studied as reagents for reductive amination of the oligosaccharides. All three amines contributed to a significant increase in sensitivity in MALDI-MS, especially for oligosaccharides with a degree of polymerization (DP) < 3. These reagents were also attractive due to their high volatility, which facilitated the purification of the reaction mixtures. It was established that low-mass discrimination in MALDI-MS in the DP range 1-7 was substantially reduced with dialkylamine derivatization. Hence, dialkylamine derivatization of cellulose ether oligosaccharides obtained by endoglucanase depolymerization increased the number of detected analyte components. Dimethylamine was concluded to be the preferred reagent of those evaluated.  相似文献   

16.
A simple, rapid, sensitive, and specific liquid chromatography-mass spectrometry (LC-MS) method was developed and validated for the quantification of amitraz and its metabolite in human serum. Both the compounds were extracted using monolithic silica spin columns with acetonitrile. The chromatographic separation was performed on a reverse-phase C(18) column with a mobile phase of 10 mM ammonium formate-acetonitrile. The protonated analyte was quantitated in positive ionization by mass spectrometry. The method was validated over the concentration range of 25-1000 ng/ml for amitraz and its metabolite in human serum. For both compounds, the limit of detection was 5 ng/ml. The method was applied to serum samples taken from an attempted suicide patient, and only small volumes of serum were required for the simultaneous determination of these compounds.  相似文献   

17.
18.
A simple, rapid and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for quantifying sibiricaxanthone F (SF) in rat plasma following oral and intravenous dosings. After addition of the internal standard (IS) kaempferol and the antioxidant, 20% ascorbic acid, plasma samples were precipitated with acetonitrile and separated on an Aglient Zorbax XDB-C(18) column (50 mm × 4.6mm I.D., 2.1 μm) with gradient acetonitrile and water (both containing 0.01% formic acid) as the mobile phase. The detection was performed on a Sciex API 4000 LC-MS/MS with electrospray ionization (ESI) inlet in the negative multiple reaction monitoring (MRM) mode. Good linearity was achieved over the concentration range of 0.5-500.0ng/mL (r>0.996). Intra- and inter-day precisions were less than 7.60%, and accuracy ranged from 97.18% to 99.84%. The lower limit of quantification for SF was 0.5 ng/mL, and analytes were stable under various conditions (during freeze-thaw, at room temperature and under deep-freeze conditions). This validated method was successfully applied to the preliminary pharmacokinetic study of SF in rats for the first time, and the absolute bioavailability of SF was found to be only 0.22 ± 0.15%.  相似文献   

19.
A high-performance liquid chromatography (HPLC) positive-ion electrospray ionization tandem mass spectrometry method for the quantification of prostaglandin glyceryl esters (PG-Gs), a newly discovered class of eicosanoids, is described. All four PG-Gs (PGE(2)-G, PGD(2)-G, PGF(2alpha)-G, and 6-keto-PGF(1alpha)-G) and the prostaglandins (PGs) that are formed by their hydrolysis are simultaneously quantified. Analytes were purified via reverse-phase solid-phase extraction, separated by reverse-phase HPLC, and quantified on a triple-quadrupole mass spectrometer using selected reaction monitoring. Quantification was achieved by stable isotope dilution employing penta-deuterated (PG-Gs) or tetra-deuterated (PGs) analogs. Analyte recovery from cell culture medium was >43% for all analytes at four different concentration levels. The limit of quantification is in the range of 25fmol on-column for each analyte and the analytes exhibit a linear response over approximately a 500-fold range. This method allows simultaneous profiling of several PG-Gs and PGs without multistep sample purification or derivatization.  相似文献   

20.
Vorinostat (suberoylanilide hydroxamic acid, SAHA) is undergoing evaluation as an antineoplastic agent. We developed a liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay for quantitating vorinostat and its major metabolites, vorinostat glucuronide and 4-anilino-4-oxobutanoic acid, in human serum. The assay uses: deuterated internal standards; acetonitrile protein precipitation; a BDS Hypersil C18 (3 microm, 100 mm x 3 mm) column; a gradient mobile phase of 0.5% acetic acid in acetonitrile and water; and electrospray positive-mode ionization with selected reaction monitoring (SRM) detection. The lower limit of quantitation was 3.0 ng/ml for each analyte. The assay is being employed in at least 12 clinical studies of vorinostat-containing regimens.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号