1.
Standard guiding catheters for coronary interventions may not selectively engage the coronary ostium despite a successful cannulation with a diagnostic catheter of the same curve. This discrepancy is explained by a slight difference in shape between the two catheters (shorter tip of the guiding, absence of tip tapering, etc.). The authors report on the use of 6 F. coronary diagnostic catheters as guiding catheters for coronary angioplasty and stent implantation in two patients with critical stenoses: in the right coronary artery distal to a right internal mammary artery anastomosis in one and in the ostial right coronary artery in the other. In both cases, the use of diagnostic catheters was the key to success despite the vessel orifice being unfavourable for the use of different types of guiding catheters.  相似文献   

2.
An injection of saline solution is required for the measurement of vessel lumen area using a conductance catheter. The injection of room temperature saline to displace blood in a vessel inevitably involves mass and heat transport and electric field conductance. The objective of the present study is to understand the accuracy of conductance method based on the phenomena associated with the saline injection into a stenotic blood vessel. Computational fluid dynamics were performed to simulate flow and its relation to transport and electric field in a stenotic artery for two different sized conductance catheters (0.9 and 0.35 mm diameter) over a range of occlusions [56-84% cross-sectional area (CSA) stenosis]. The results suggest that the performance of conductance catheter is dependent on catheter size and severity of stenosis more significantly for 0.9 mm than for 0.35 mm catheter. Specifically, the time of detection of 95% of injected saline solution at the detection electrodes was shown to range from 0.67 to 3.7 s and 0.82 to 0.94 s for 0.9 mm and 0.35 mm catheter, respectively. The results also suggest that the detection electrodes of conductance catheter should be placed outside of flow recirculation region distal to the stenosis to minimize the detection time. Finally, the simulations show that the accuracy in distal CSA measurements, however, is not significantly altered by whether the position of detection electrodes is inside or outside of recirculation zone (error was within 12% regardless of detection electrodes position). The results were experimentally validated for one lesion geometry and the simulation results are within 8% of actual measurements. The simulation of conductance catheter injection method may lead to further optimization of device and method for accurate sizing of diseased coronary arteries, which has clinical relevance to percutaneous intervention.  相似文献   

3.
We developed a device that delivers fluid through a catheter at a constant rate and can be used in conscious animals to solve a variety of problems. For example, this device can be used for delivering drugs and maintaining intravascular catheter patency. The device provides infusions at low flows (1.0-1.5 ml/day), so that experimental agents may be administered with minimal volume loading of the rat. Arterial and venous catheter patency is maintained by infusion of heparinized saline through indwelling catheters attached to the device. The catheters exit from the rat in the intrascapular area and are routed through a protective spring to the device, which is suspended above the cage. The catheters may be attached to pressure transducers, blood may be sampled, and injections or infusions may be made without disturbing the rat. Because the device is self-contained, it can be suspended by a fluid-free swivel that rotates through 360 degrees, providing minimal restraint. The device has been used successfully to measure arterial and central venous blood pressures in two studies using rats.  相似文献   

4.
Aspiration thrombectomy is one of the most effective systems for blood clot removal and vessel recanalization. We present the results of a study involving the modelling and extraction of blood clots in the arteries of the human body using the following computer tools: Bond-Graph methodology for the fluid domain and Multi-Body Simulation for the mechanical domain. The modelling for the mechanical domain focuses on the clot and the distal end section of an aspiration device. Our final model considers an elastic characterization of the blood clot with progressive detachment from the vessel wall. We conclude that the results of such modelling could potentially improve the effectiveness of blood clot removal by reducing the risk of clot fragmentation. Such modelling could also potentially provide an adjunct technique in improving recanalization of arteries over a range of given parameters (mechanical properties of the vessel, mechanical properties of the blood clot, blood clot length, suction pressure, catheter – clot distance, catheter shape, catheter diameter and vessel occlusion).  相似文献   

5.
Formation of fibrin sleeves around catheter tips is a central factor in catheter failure during chronic implantation, and such tissue growth can occur despite administration of anticoagulants. We developed a novel method for monitoring catheter patency. This method recognizes the progressive nature of catheter occlusion, and tracks this process over time through measurement of changes in catheter resistance to a standardized 1 mL bolus infusion from a pressurized reservoir. Two indirect measures of catheter patency were used: (a) reservoir residual pressure and (b) reservoir discharge time. This method was applied to the study of catheter patency in rats comparing the effect of catheter material (silastic, polyurethane, Microrenathanetrade mark), lock solution (heparin, heparin/dexamethasone) and two different cannulation sites (superior vena cava via the external jugular vein, inferior vena cava via the femoral vein). Our findings reveal that application of flexible smaller-size silastic catheters and a dexamethasone lock solution resulted in prolonged catheter patency. Patency could be maintained over nine weeks with the femoral vein catheters, compared with five weeks with the external jugular vein catheters. The current method for measuring catheter patency provides a useful index for the assessment of tissue growth around the catheter tip. The method also provides an objective and quantitative way of comparing changes in catheter patency for different surgical methods and catheter types. Our method improves on the conventional method of assessing catheter occlusion by judging the ability to aspirate from the catheter.  相似文献   

6.
A nonhuman primate model comprising adult male rhesus monkeys (Macaca mulatta) with chronically indwelling subcutaneous central venous access devices provides a unique opportunity to determine plasma pharmacokinetics of new drugs such as anticancer and anti- retroviral agents. The central venous access we use is a low-profile, single-septum, titanium port that is attached to a radiopaque, indwelling catheter; the catheter is implanted in an internal jugular vein. A common complication following placement of the venous access device was migration of the catheter tip. We therefore modified the standard procedure by cutting the silicone catheter and introducing the rigid connector to secure the catheter to the vessel at the insertion site (approximately 9 to 13 cm from the distal end of the catheter). Prior to the use of the connector, three of five catheters migrated within 4 weeks after placement. In contrast, all 13 internal jugular catheters with connectors have remained patent without migration of the catheter tip. Therefore, incorporation of the catheter connector appears to have eliminated the problem of catheter migration.  相似文献   

7.
The engineering of human tissue represents a major paradigm shift in clinical medicine. Early embodiments of tissue engineering are currently being taken forward to the clinic by production methods that are essentially extensions of laboratory manual procedures. However, to achieve the status of routine large-scale clinical practice, automation and scale-out processes are required. This in turn will require the development of reliable on-line monitoring and control systems. This paper examines one demand of crucial importance, namely the real time in vitro monitoring of the flow characteristics through growing tissue since this has a complex interrelationship. Doppler optical coherence tomography (DOCT) is a recently developed imaging technique for studying the rheological properties of tissues in vivo. Capable of non-invasive imaging in real time with high resolution, it is potentially ideal for the continuous monitoring of engineered tissues in vitro. As a base line, the current status of DOCT in vivo is therefore reviewed. This paper also reports the first preliminary use of DOCT in tissue engineering. The application described involves the imaging of a fully developed laminar flow through a combined tissue fabrication/bioreactor with a tissue-engineered construct (substitute blood vessel) in situ.  相似文献   

8.
Coronary collateral growth (arteriogenesis) is a physiological adaptive response to transient and repetitive occlusion of major coronary arteries in which small arterioles (native collaterals) with minimal to no blood flow remodel into larger conduit arteries capable of supplying adequate perfusion to tissue distal to the site of occlusion. The ability to reliably and reproducibly mimic transient, repetitive coronary artery occlusion (ischemia) in animal models is critical to the development of therapies to restore coronary collateral development in type II diabetes and the metabolic syndrome. Current animal models for repetitive coronary artery occlusion implement a pneumatic occluder (balloon) that is secured onto the surface of the heart with the suture, which is inflated manually, via a catheter connected to syringe, to effect occlusion of the left anterior descending coronary artery (LAD). This method, although effective, presents complications in terms of reproducibility and practicality. To address these limitations, we have designed a device for automated, transient inflation of balloon catheters in coronary artery occlusion models. This device allows repeated, consistent inflation (to either specified pressure or volume) and the capability for implementing very complex, month-long protocols. This system has significantly increased the reproducibility of coronary collateral growth studies in our laboratory, resulting in a significant decrease in the numbers of animals needed to complete each study while relieving laboratory personnel from the burden of extra working hours and enabling us to continue studies over periods when we previously could not. In this paper, we present all details necessary for construction and operation of the inflator. In addition, all of the components for this device are commercially available and economical (Table S1). It is our hope that the adoption of automated balloon catheter inflation protocols will improve the experimental reliability of transient ischemia studies at many research institutions.  相似文献   

9.
A variety of devices has been used for measuring flow properties of deep-lying arteries, but many have limitations. This paper describes a relatively nontraumatic intravenous approach which uses a catheter in connection with a pulsed ultrasonic Doppler velocity meter (PUDVM) and an ultrasound echo track. The venous ultrasound catheter (VUC) has permitted measurements of local instantaneols blood velocity, flow, and wall motion in the abdominal aorta and iliac arteries of beagle dogs; evaluation studies have been conducted to compare the VUC recordings with an independent method for measuring blood flow and wall motion. Coupling of this catheter-tip device with the PUDVM and echo track provides chronic measurements of hemodynamic parameters in these deep vessels which were virtually impossible to obtain previously. This technique may prove useful in monitoring vessel pathology longitudinally as well as in basic experimental situations requiring flow and arterial wall mechanical properties.  相似文献   

10.
J L Cox  A I Gotlieb 《CMAJ》1986,134(10):1129-1132
Percutaneous transluminal coronary angioplasty (PTCA) has been used clinically for 8 years and is becoming widely accepted in the treatment of atherosclerotic coronary artery disease. Since the long-term effects of the procedure are unknown, the rate of restenosis following the procedure, approximately 30%, is of major concern. We briefly review the current status of PTCA and the effect of angioplasty on the vessel wall and discuss proposed mechanisms of recurrent stenosis.  相似文献   

11.
基于血管内高频超声的血管壁组织应变成像及弹性重构   总被引:5,自引:0,他引:5  
利用血管内高频超声(Intravascular Ultrasound,IVUS)成像技术,对IVUS图像灰度值进行换能器偏心校正后,提出了基于遗传算法的管壁组织运动分阶叠加光流估计方法获得血管内施压条件下组织微元位移与应变分布,采用弹性重构方法获得了实际血管壁真正意义上的横断面弹性显微图像,由离体猪血管实验结果证实。将血管力学实验研究推进到二维亚毫米微结构层次,有希望为经皮腔内冠状动脉血管形术(Percutaneous Transluminal Coronary Angioplasty,PTCA)过程监控与治疗评价提供新的技术手段。  相似文献   

12.
In this report, the results of complementary studies of pressure-volume (p-V) measurements on balloon catheters with balloons of low (LC) and high compliance (HC) used for percutaneous transluminal coronary angioplasty are discussed. The measurements were performed with balloons unconfined in air (free dilatation) and also confined in different shells. In the case of rigid shells, a surprisingly high self-expansion of the catheters was found. Although this self-expansion does not contribute to the radial dilatation, it cannot be neglected, but must be taken into account when the success of balloon dilatation is determined on the basis of measured p-V curves. The investigations performed using wrapped shells clearly show the different dilatation properties of LC and HC balloons. The results provide important information on the feasibility of controlled balloon dilatation on the basis of p-V measurements performed on-line during PTCA.  相似文献   

13.
The YUMIKO catheter (Goodman, Nagoya, Japan) was recently developed for a left internal mammary artery (IMA) angiography with a right radial or brachial approach. The present authors experienced an interesting case where the YUMIKO catheter was useful for a right IMA angiography via a right brachial artery. A 53-year-old man with bilateral IMA grafts underwent follow-up coronary angiography via a right brachial artery. Native coronary artery and left IMA angiography were performed without difficulty using the Judkins Right and Left and YUMIKO catheters. Angiography of the right IMA was attempted with the Judkins Right catheter and IMA catheter, resulting in a nonselective angiogram with poor imaging. The YUMIKO catheter, however, enabled smooth cannulation to the right IMA and provided good images of the selective right IMA angiography.  相似文献   

14.
Little is known about the forces and moments acting on the spinal column during various movements and activities, and thus about the loading of implants used in the treatment of spinal fractures. A measuring method using an external fixation device was developed to determine the in vivo loading of spinal implants. On the basis of these data the forces acting on the spine can be calculated. The present paper describes this measuring method as applied to the fixation device, and initial experience with this device in a first application is presented.  相似文献   

15.
Primary coronary angioplasty has been shown to be an effective reperfusion therapy for patients with acute myocardial infarction, not only for those who present to PTCA centres but also for patients who present to hospitals without angioplasty facilities. With the increasing use of primary angioplasty more patients will be transferred to a (tertiary) PTCA centre. An increase in treatment delay is associated with a worse clinical outcome. The importance of an open infarct-related vessel at acute angiography is becoming clear. Pharmacological pretreatment of patients during transportation to a PTCA centre with the aim to open the infarct-related vessel in advance might be beneficial. Glycoprotein IIb/IIIa receptor blockers seem to be the agents of choice for facilitated PTCA. The safety and (cost) effectiveness of this pretreatment of patients transported to undergo primary angioplasty remain to be evaluated.  相似文献   

16.
庄瑜  刘俊  肖明第 《生物磁学》2009,(15):2950-2953
冠脉内支架植入是临床上预防PTCA术后再狭窄并发症的有效措施,但金属支架仅在植入早期发生作用,在冠脉内壁修复完成后则成为多余的负担,可能激活血小板及多种凝血因子聚集导致血栓形成及刺激血管壁造成心脏事件及再狭窄的发生。针对上述问题,生物可降解冠状动脉支架的研究得到了相当的发展。本文就可降解支架的发展及现状作一简要综述。  相似文献   

17.
Distal embolization of particulate matter complicates percutaneous coronary and peripheral interventions more often than had been recognized until recently. A number of distal protection devices are under development. The PercuSurge GuardWire™ is a balloon occlusion thrombectomy device approved by the United States Food and Drug Administration for saphenous vein graft intervention. A number of filter devices utilize an expandable filter mounted on the angioplasty guidewire to facilitate entrapment of particles and safe removal. The Parodi Anti-Emboli System™ is an example of a catheter occlusion device that establishes protection by reversing blood flow in the target vessel.  相似文献   

18.
Recent clinical studies of the percutaneous transvenous mitral annuloplasty (PTMA) devices have shown a short-term reduction of mitral regurgitation after implantation. However, adverse events associated with the devices such as compression and perforation of vessel branches, device migration and fracture were reported. In this study, a finite element analysis was carried out to investigate the biomechanical interaction between the proximal anchor stent of a PTMA device and the coronary sinus (CS) vessel in three steps including: (i) the stent release and contact with the CS wall, (ii) the axial pull t the stent connector and (iii) the pressure inflation of the vessel wall. To investigate the impact of the material properties of tissues and stents on the interactive responses, the CS vessel was modelled with human and porcine material properties, and the proximal stent was modelled with two different Nitinol materials with one being stiffer than the other. The results indicated that the vessel wall stresses and contact forces imposed by the stents were much higher in the human model than the porcine model. However, the mechanical differences induced by the two stent types were relatively small. The softer stent exhibited a better fatigue safety factor when deployed in the human model than in the porcine model. These results underscored the importance of the CS tissue mechanical properties. Vessel wall stress and stent radial force obtained in the human model were higher than those obtained in the porcine model, which also brought up questions as to the validity of using the porcine model to assess device mechanical function. The quantification of these biomechanical interactions can offer scientific insight into the development and optimisation of the PTMA device design.  相似文献   

19.
A novel shear-test device for soft biological tissue, capable of applying simple shear deformations simultaneously in two orthogonal directions while measuring the resulting forces generated in three axes, is described. We validated the device using a synthetic gel, the properties of which were ascertained from independent tensile and rotational shear tests. Material parameters for the gel were fitted using neo-Hookean analytical solutions to the independent test data, and these matched the results from the device. Preliminary results obtained with rat septal myocardium are also presented to demonstrate the feasibility of the apparatus in determining the shear characteristics of living tissue.  相似文献   

20.
目的设计一种大鼠长期腰蛛网膜下腔置管模型中微导管体外端的保护装置,并证明其有效性。方法 24只清洁级SD大鼠分为对照组(n=12)和应用装置组(n=12),术前1 d和术后第1、3、7天行转棒和热水甩尾试验,检查置入装置对大鼠运动及感觉神经功能影响情况。计数术后大鼠导管保留情况,利多卡因试验证实导管性能。结果本次试验两组大鼠术后均无死亡及明显瘫痪情况;术前及术后1,3,7 d转棒实验及热水甩尾实验均未见两组明显差异(P〉0.05,独立样本T检验,);对照组体外导管末端在术后几天内被损毁或拔出无法进行进一步实验,术后第7天应用装置组所有导管末端仍保持完整,利多卡因实验显示导管功能良好(P〉0.05,χ2检验)。结论该装置可有效保护置入大鼠腰蛛网膜下腔导管的体外端,非常适用于需要长期反复腰蛛网膜下腔注射的研究。  相似文献   