1.
Stable isotope tagging methods have enabled relative quantitation of proteins between samples in LC-MS/MS analyses. However, most such methods are not applicable to the differential quantitation of modified proteins because the isotope tagging reagents only react with certain peptides or because the reagents incorporate a mass increment that is too small to allow reliable quantitation on low resolution ion trap MS instruments. Here, we describe the use of d0- and d5-phenyl isocyanate (PIC) as N-terminal reactive tags for essentially all peptides in proteolytic digests. PIC reacts quantitatively with peptide N-terminal amines within minutes at neutral pH and the PIC-labeled peptides undergo informative MS/MS fragmentation. Ratios of d0- and d5-PIC-labeled derivatives of several model peptides were linear across a 10000-fold range of peptide concentration ratios, thus indicating a wide dynamic range for quantitation. Application of PIC labeling enabled relative quantitation of several styrene oxide adducts of human hemoglobin in LC-MS/MS analyses. PIC labeling offers a versatile means of quantifying changes in modified or variant protein forms in paired samples.  相似文献   

2.
The study of changes in protein levels between samples derived from cells representing different biological conditions is a key to the understanding of cellular function. There are two main methods available that allow both for global scanning for significantly varying proteins and targeted profiling of proteins of interest. One method is based on 2-D gel electrophoresis and image analysis of labelled proteins. The other method is based on LC-MS/MS analysis of either unlabelled peptides or peptides derived from isotopically labelled proteins or peptides. In this study, the non-labelling approach was used involving a new software, DeCyder MS Differential Analysis Software (DeCyder MS) intended for automated detection and relative quantitation of unlabelled peptides in LC-MS/MS data.Total protein extracts of E. coli strains expressing varying levels of dihydrofolate reductase and integron integrase were digested with trypsin and analyzed using a nanoscale liquid chromatography system, Ettan MDLC, online connected to an LTQTM linear ion-trap mass spectrometer fitted with a nanospray interface. Acquired MS data were subjected to DeCyder MS analysis where 2-D representations of the peptide patterns from individual LC-MS/MS analyses were matched and compared.This approach to unlabelled quantitative analysis of the E. coli proteome resulted in relative protein abundances that were in good agreement with results obtained from traditional methods for measuring protein levels.  相似文献   

3.
A new algorithm (QN) for the (15)N /(14)N quantitation of relative protein abundances in complex proteomic samples is described. QN takes advantage of the high resolution, mass accuracy and throughput of the hybrid mass spectrometer LTQ-FT MS. Peptide quantitation is based on MS peak intensity (measured in the FT MS), while peptide identification is performed in the MS/MS mode (measured in the LTQ linear ion trap). Accuracy of the protein abundance is enhanced by a novel scoring procedure, allowing filtering of less reliable measurements of peptide abundances. The performance of QN is illustrated in the relative quantitative analysis of M. acetivorans C2A cultures grown with carbon monoxide vs methanol as substrate. Roughly 1,000 proteins were quantitated with an average CV of 9% for the protein abundance ratios. QN performs quantitation without manual intervention, does not require high processing power, and generates files compatible with the Guidelines for Proteomic Data Publication.  相似文献   

4.
Verification of candidate biomarker proteins in blood is typically done using multiple reaction monitoring (MRM) of peptides by LC-MS/MS on triple quadrupole MS systems. MRM assay development for each protein requires significant time and cost, much of which is likely to be of little value if the candidate biomarker is below the detection limit in blood or a false positive in the original discovery data. Here we present a new technology, accurate inclusion mass screening (AIMS), designed to provide a bridge from unbiased discovery to MS-based targeted assay development. Masses on the software inclusion list are monitored in each scan on the Orbitrap MS system, and MS/MS spectra for sequence confirmation are acquired only when a peptide from the list is detected with both the correct accurate mass and charge state. The AIMS experiment confirms that a given peptide (and thus the protein from which it is derived) is present in the plasma. Throughput of the method is sufficient to qualify up to a hundred proteins/week. The sensitivity of AIMS is similar to MRM on a triple quadrupole MS system using optimized sample preparation methods (low tens of ng/ml in plasma), and MS/MS data from the AIMS experiments on the Orbitrap can be directly used to configure MRM assays. The method was shown to be at least 4-fold more efficient at detecting peptides of interest than undirected LC-MS/MS experiments using the same instrumentation, and relative quantitation information can be obtained by AIMS in case versus control experiments. Detection by AIMS ensures that a quantitative MRM-based assay can be configured for that protein. The method has the potential to qualify large number of biomarker candidates based on their detection in plasma prior to committing to the time- and resource-intensive steps of establishing a quantitative assay.  相似文献   

5.

Background

Label-free quantitation of mass spectrometric data is one of the simplest and least expensive methods for differential expression profiling of proteins and metabolites. The need for high accuracy and performance computational label-free quantitation methods is still high in the biomarker and drug discovery research field. However, recent most advanced types of LC-MS generate huge amounts of analytical data with high scan speed, high accuracy and resolution, which is often impossible to interpret manually. Moreover, there are still issues to be improved for recent label-free methods, such as how to reduce false positive/negatives of the candidate peaks, how to expand scalability and how to enhance and automate data processing. AB3D (A simple label-free quantitation algorithm for Biomarker Discovery in Diagnostics and Drug discovery using LC-MS) has addressed these issues and has the capability to perform label-free quantitation using MS1 for proteomics study.

Results

We developed an algorithm called AB3D, a label free peak detection and quantitative algorithm using MS1 spectral data. To test our algorithm, practical applications of AB3D for LC-MS data sets were evaluated using 3 datasets. Comparisons were then carried out between widely used software tools such as MZmine 2, MSight, SuperHirn, OpenMS and our algorithm AB3D, using the same LC-MS datasets. All quantitative results were confirmed manually, and we found that AB3D could properly identify and quantify known peptides with fewer false positives and false negatives compared to four other existing software tools using either the standard peptide mixture or the real complex biological samples of Bartonella quintana (strain JK31). Moreover, AB3D showed the best reliability by comparing the variability between two technical replicates using a complex peptide mixture of HeLa and BSA samples. For performance, the AB3D algorithm is about 1.2 - 15 times faster than the four other existing software tools.

Conclusions

AB3D is a simple and fast algorithm for label-free quantitation using MS1 mass spectrometry data for large scale LC-MS data analysis with higher true positive and reasonable false positive rates. Furthermore, AB3D demonstrated the best reproducibility and is about 1.2- 15 times faster than those of existing 4 software tools.

Electronic supplementary material

The online version of this article (doi:10.1186/s12859-014-0376-0) contains supplementary material, which is available to authorized users.  相似文献   

6.
Mass spectrometers that provide high mass accuracy such as FT-ICR instruments are increasingly used in proteomic studies. Although the importance of accurately determined molecular masses for the identification of biomolecules is generally accepted, its role in the analysis of shotgun proteomic data has not been thoroughly studied. To gain insight into this role, we used a hybrid linear quadrupole ion trap/FT-ICR (LTQ FT) mass spectrometer for LC-MS/MS analysis of a highly complex peptide mixture derived from a fraction of the yeast proteome. We applied three data-dependent MS/MS acquisition methods. The FT-ICR part of the hybrid mass spectrometer was either not exploited, used only for survey MS scans, or also used for acquiring selected ion monitoring scans to optimize mass accuracy. MS/MS data were assigned with the SEQUEST algorithm, and peptide identifications were validated by estimating the number of incorrect assignments using the composite target/decoy database search strategy. We developed a simple mass calibration strategy exploiting polydimethylcyclosiloxane background ions as calibrant ions. This strategy allowed us to substantially improve mass accuracy without reducing the number of MS/MS spectra acquired in an LC-MS/MS run. The benefits of high mass accuracy were greatest for assigning MS/MS spectra with low signal-to-noise ratios and for assigning phosphopeptides. Confident peptide identification rates from these data sets could be doubled by the use of mass accuracy information. It was also shown that improving mass accuracy at a cost to the MS/MS acquisition rate substantially lowered the sensitivity of LC-MS/MS analyses. The use of FT-ICR selected ion monitoring scans to maximize mass accuracy reduced the number of protein identifications by 40%.  相似文献   

7.
Mass spectrometry coupled to liquid chromatography (LC-MS and LC-MS/MS) is commonly used to analyze the protein content of biological samples in large scale studies, enabling quantitation and identification of proteins and peptides using a wide range of experimental protocols, algorithms, and statistical models to analyze the data. Currently it is difficult to compare the plethora of algorithms for these tasks. So far, curated benchmark data exists for peptide identification algorithms but data that represents a ground truth for the evaluation of LC-MS data is limited. Hence there have been attempts to simulate such data in a controlled fashion to evaluate and compare algorithms. We present MSSimulator, a simulation software for LC-MS and LC-MS/MS experiments. Starting from a list of proteins from a FASTA file, the simulation will perform in-silico digestion, retention time prediction, ionization filtering, and raw signal simulation (including MS/MS), while providing many options to change the properties of the resulting data like elution profile shape, resolution and sampling rate. Several protocols for SILAC, iTRAQ or MS(E) are available, in addition to the usual label-free approach, making MSSimulator the most comprehensive simulator for LC-MS and LC-MS/MS data.  相似文献   

8.
Quantitative proteomics approaches using stable isotopes are well-known and used in many labs nowadays. More recently, high resolution quantitative approaches are reported that rely on LC-MS quantitation of peptide concentrations by comparing peak intensities between multiple runs obtained by continuous detection in MS mode. Characteristic of these comparative LC-MS procedures is that they do not rely on the use of stable isotopes; therefore the procedure is often referred to as label-free LC-MS. In order to compare at comprehensive scale peak intensity data in multiple LC-MS datasets, dedicated software is required for detection, matching and alignment of peaks. The high accuracy in quantitative determination of peptide abundance provides an impressive level of detail. This approach also requires an experimental set-up where quantitative aspects of protein extraction and reproducible separation conditions need to be well controlled. In this paper we will provide insight in the critical parameters that affect the quality of the results and list an overview of the most recent software packages that are available for this procedure.  相似文献   

9.
The discovery of unanticipated protein modifications is one of the most challenging problems in proteomics. Whereas widely used algorithms such as Sequest and Mascot enable mapping of modifications when the mass and amino acid specificity are known, unexpected modifications cannot be identified with these tools. We have developed an algorithm and software called P-Mod, which enables discovery and sequence mapping of modifications to target proteins known to be represented in the analysis or identified by Sequest. P-Mod matches MS/MS spectra to peptide sequences in a search list. For spectra of modified peptides, P-Mod calculates mass differences between search peptide sequences and MS/MS precursors and localizes the mass shift to a sequence position in the peptide. Because modifications are detected as mass shifts, P-Mod does not require the user to guess at masses or sequence locations of modifications. P-Mod uses extreme value statistics to assign p value estimates to sequence-to-spectrum matches. The reported p values are scaled to account for the number of comparisons, so that error rates do not increase with the expanded search lists that result from incorporating potential peptide modifications. Combination of P-Mod searches from multiple LC-MS/MS analyses and multiple samples revealed previously unreported BSA modifications, including a novel decarboxymethylation or D-->G substitution at position 579 of the protein. P-Mod can serve a unique role in the identification of protein modifications both from exogenous and endogenous sources and may be useful for identifying modified protein forms as biomarkers for toxicity and disease processes.  相似文献   

10.

Background  

Relative isotope abundance quantification, which can be used for peptide identification and differential peptide quantification, plays an important role in liquid chromatography-mass spectrometry (LC-MS)-based proteomics. However, several major issues exist in the relative isotopic quantification of peptides on time-of-flight (TOF) instruments: LC peak boundary detection, thermal noise suppression, interference removal and mass drift correction. We propose to use the Maximum Ratio Combining (MRC) method to extract MS signal templates for interference detection/removal and LC peak boundary detection. In our method, MRCQuant, MS templates are extracted directly from experimental values, and the mass drift in each LC-MS run is automatically captured and compensated. We compared the quantification accuracy of MRCQuant to that of another representative LC-MS quantification algorithm (msInspect) using datasets downloaded from a public data repository.  相似文献   

11.
Isotopic labeling of cysteine residues with acrylamide was previously utilized for relative quantitation of proteins by MALDI-TOF. Here, we explored and compared the application of deuterated and (13)C isotopes of acrylamide for quantitative proteomic analysis using LC-MS/MS and high-resolution FTICR mass spectrometry. The method was applied to human serum samples that were immunodepleted of abundant proteins. Our results show reliable quantitation of proteins across an abundance range that spans 5 orders of magnitude based on ion intensities and known protein concentration in plasma. The use of (13)C isotope of acrylamide had a slightly greater advantage relative to deuterated acrylamide, because of shifts in elution of deuterated acrylamide relative to its corresponding nondeuterated compound by reversed-phase chromatography. Overall, the use of acrylamide for differentially labeling intact proteins in complex mixtures, in combination with LC-MS/MS provides a robust method for quantitative analysis of complex proteomes.  相似文献   

12.
We present a method for peptide and protein identification based on LC-MS profiling. The method identified peptides at high-throughput without expending the sequencing time necessary for CID spectra based identification. The measurable peptide properties of mass and liquid chromatographic elution conditions are used to characterize and differentiate peptide features, and these peptide features are matched to a reference database from previously acquired and archived LC-MS/MS experiments to generate sequence assignments. The matches are scored according to the probability of an overlap between the peptide feature and the database peptides resulting in a ranked list of possible peptide sequences for each peptide submitted. This method resulted in 6 times more peptide sequence identifications from a single LC-MS analysis of yeast than from shotgun peptide sequencing using LC-MS/MS.  相似文献   

13.
A frequent goal of MS‐based proteomics experiments nowadays is to quantify changes in the abundance of proteins across several biological samples. The iTRAQ labeling method is a powerful technique; when combined with LC coupled to MS/MS it allows relative quantitation of up to eight different samples simultaneously. Despite the usefulness of iTRAQ current software solutions have limited functionality and require the combined use of several software programs for analysis of the data from different MS vendors. We developed an integrated tool, now available in the virtual expert mass spectrometrist (VEMS) program, for database‐dependent search of MS/MS spectra, quantitation and database storage for iTRAQ‐labeled samples. VEMS also provides useful alternative report types for large‐scale quantitative experiments. The implemented statistical algorithms build on quantitative algorithms previously used in proposed iTRAQ tools as described in detail herein. We propose a new algorithm, which provides more accurate peptide ratios for data that show an intensity‐dependent saturation. The accuracy of the proposed iTRAQ algorithm and the performance of VEMS are demonstrated by comparing results from VEMS, MASCOT and PEAKS Q obtained by analyzing data from a reference mixture of six proteins. Users can download VEMS and test data from “ http://www.portugene.com/software.html ”.  相似文献   

14.
3-nitrotyrosine (3NT) is an oxidative posttranslational modification associated with many diseases. Determining the specific sites of this modification remains a challenge due to the low stoichiometry of 3NT modifications in biological samples. Mass spectrometry-based proteomics is a powerful tool for identifying 3NT modifications, however several reports identifying 3NT sites were later demonstrated to be incorrect, highlighting that both the accuracy and efficiency of these workflows need improvement. To advance our understanding of the chromatographic and spectral properties of 3NT-containing peptides we have adapted a straightforward, reproducible procedure to generate a large set of 3NT peptides by chemical nitration of a defined, commercially available 48 protein mixture. Using two complementary LC-MS/MS platforms, a QTOF (QSTAR Elite) and dual pressure ion trap mass spectrometer (LTQ Velos), we detected over 200 validated 3NT-containing peptides with significant overlap in the peptides detected by both systems. We investigated the LC-MS/MS properties for each peptide manually using defined criteria and then assessed their utility to confirm that the peptide was 3NT modified. This broad set of validated 3NT-containing peptides can be utilized to optimize mass spectrometric instrumentation and data mining strategies or further develop 3NT peptide enrichment strategies for this biologically important, oxidative posttranslational modification.  相似文献   

15.
The main goal of many proteomics experiments is an accurate and rapid quantification and identification of regulated proteins in complex biological samples. The bottleneck in quantitative proteomics remains the availability of efficient software to evaluate and quantify the tremendous amount of mass spectral data acquired during a proteomics project. A new software suite, ICPLQuant, has been developed to accurately quantify isotope‐coded protein label (ICPL)‐labeled peptides on the MS level during LC‐MALDI and peptide mass fingerprint experiments. The tool is able to generate a list of differentially regulated peptide precursors for subsequent MS/MS experiments, minimizing time‐consuming acquisition and interpretation of MS/MS data. ICPLQuant is based on two independent units. Unit 1 performs ICPL multiplex detection and quantification and proposes peptides to be identified by MS/MS. Unit 2 combines MASCOT MS/MS protein identification with the quantitative data and produces a protein/peptide list with all the relevant information accessible for further data mining. The accuracy of quantification, selection of peptides for MS/MS‐identification and the automated output of a protein list of regulated proteins are demonstrated by the comparative analysis of four different mixtures of three proteins (Ovalbumin, Horseradish Peroxidase and Rabbit Albumin) spiked into the complex protein background of the DGPF Proteome Marker.  相似文献   

16.
We have developed a real-time graphic-processor-unit-based search engine capable of high-quality peptide identifications in <500 μs per spectrum. The steps of peptide/protein identification, in-silico prediction of all possible tryptic peptides from these proteins, and the prediction of their expected retention times and m/z values take less than 5 s per cycle over ~3000 MS/MS spectra. This lays the foundation for information-dependent acquisition with exclusion lists generated on-the-fly, as the instrument continues to acquire data. While a complete evaluation of the dynamic exclusion system requires the participation from instrument vendors, we conducted a series of model experiments using a whole cell tryptic digestion of the bacterium Clostridium thermocellum. We ran a series of five iterative LC-MS/MS runs, adding a new exclusion list at each of four chromatographic "tripping points" - the elution times of the four standard peptides spiked into the sample. Retention times of these standard peptides were also used for real-time "chromatographic calibration." The dynamic exclusion approach gave a ≈ 5% increase in confident protein identification (for typical 2 h LC-MS/MS run), and reduced the average number of identified peptides per protein from 4.7 to 2.9. Its application to a two-times shorter gradient gave a ≈ 17% increase in proteins identified. Further improvements are possible for instruments with better mass accuracy, by employing a more accurate retention prediction algorithm and by developing better understanding of the possible chemical modifications and fragmentations produced during electrospray ionization.  相似文献   

17.
Exemestane is an irreversible aromatase inhibitor used for anticancer therapy. Unfortunately, this drug is also misused in sports to avoid some adverse effects caused by steroids administration. For this reason exemestane has been included in World Anti-Doping Agency prohibited list. Usually, doping control laboratories monitor prohibited substances through their metabolites, because parent compounds are readily metabolized. Thus metabolism studies of these substances are very important. Metabolism of exemestane in humans is not clearly reported and this drug is detected indirectly through analysis of its only known metabolite: 17β-hydroxyexemestane using liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) and gas chromatography coupled to mass spectrometry (GC-MS). This drug is extensively metabolized to several unknown oxidized metabolites. For this purpose LC-MS/MS has been used to propose new urinary exemestane metabolites, mainly oxidized in C6-exomethylene and simultaneously reduced in 17-keto group. Urine samples from four volunteers obtained after administration of a 25mg dose of exemestane were analyzed separately by LC-MS/MS. Urine samples of each volunteer were hydrolyzed followed by liquid-liquid extraction and injected into a LC-MS/MS system. Three unreported metabolites were detected in all urine samples by LC-MS/MS. The postulated structures of the detected metabolites were based on molecular formulae composition obtained through high accuracy mass determination by liquid chromatography coupled to hybrid quadrupole-time of flight mass spectrometry (LC-QTOF MS) (all mass errors below 2ppm), electrospray (ESI) product ion spectra and chromatographic behavior.  相似文献   

18.
The peptide‐based quantitation accuracy and precision of LC‐ESI (QSTAR Elite) and LC‐MALDI (4800 MALDI TOF/TOF) were compared by analyzing identical Escherichia coli tryptic digests containing iTRAQ‐labeled peptides of defined abundances (1:1, 2.5:1, 5:1, and 10:1). Only 51.4% of QSTAR spectra were used for quantitation by ProteinPilot Software versus 66.7% of LC‐MALDI spectra. The average protein sequence coverages for LC‐ESI and LC‐MALDI were 24.0 and 18.2% (14.9 and 8.4 peptides per protein), respectively. The iTRAQ‐based expression ratios determined by ProteinPilot from the 57 467 ESI‐MS/MS and 26 085 MALDI‐MS/MS spectra were analyzed for measurement accuracy and reproducibility. When the relative abundances of peptides within a sample were increased from 1:1 to 10:1, the mean ratios calculated on both instruments differed by only 0.7–6.7% between platforms. In the 10:1 experiment, up to 64.7% of iTRAQ ratios from LC‐ESI MS/MS spectra failed S/N thresholds and were excluded from quantitation, while only 0.1% of the equivalent LC‐MALDI iTRAQ ratios were rejected. Re‐analysis of an archived LC‐MALDI sample set stored for 5 months generated 3715 MS/MS spectra for quantitation, compared with 3845 acquired originally, and the average ratios differed by only 3.1%. Overall, MS/MS‐based peptide quantitation performance of offline LC‐MALDI was comparable with on‐line LC‐ESI, which required threefold less time. However, offline LC‐MALDI allows the re‐analysis of archived HPLC‐separated samples.  相似文献   

19.
When analyzing proteins in complex samples using tandem mass spectrometry of peptides generated by proteolysis, the inference of proteins can be ambiguous, even with well-validated peptides. Unresolved questions include whether to show all possible proteins vs a minimal list, what to do when proteins are inferred ambiguously, and how to quantify peptides that bridge multiple proteins, each with distinguishing evidence. Here we describe IsoformResolver, a peptide-centric protein inference algorithm that clusters proteins in two ways, one based on peptides experimentally identified from MS/MS spectra, and the other based on peptides derived from an in silico digest of the protein database. MS/MS-derived protein groups report minimal list proteins in the context of all possible proteins, without redundantly listing peptides. In silico-derived protein groups pull together functionally related proteins, providing stable identifiers. The peptide-centric grouping strategy used by IsoformResolver allows proteins to be displayed together when they share peptides in common, providing a comprehensive yet concise way to organize protein profiles. It also summarizes information on spectral counts and is especially useful for comparing results from multiple LC-MS/MS experiments. Finally, we examine the relatedness of proteins within IsoformResolver groups and compare its performance to other protein inference software.  相似文献   

20.
Quantitative mass spectrometry-based proteomics is a vital tool in modern life science research. In contrast to the popularity of approaches for relative protein quantitation, the widespread use of absolute quantitation has been hampered by inefficient and expensive production of labeled protein standards. To optimize production of isotopically labeled standards, we genetically modified a commonly employed protein expression Escherichia coli strain, BL21 (DE3), to construct an auxotroph for arginine and lysine. This bacterial strain allows low-cost, high-level expression of fully labeled proteins with no conversion of labeled arginine to proline. In combination with a fluorescence-based quantitation of standards and nontargeted LC-MS/MS analysis of unfractionated total cell lysates, this strain was used to determine the copy number of a post-translational modifier, small ubiquitin-like modifier (SUMO-2), in HeLa, human sperm, and chronic lymphocytic leukemia cells. By streamlining and improving the generation of labeled standards, this production system increases the breadth of absolute quantitation by mass spectrometry and will facilitate a far wider uptake of this important technique than previously possible.  相似文献   