首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
In this article, an antibiotic, lincomycin was determined in the urine sample by microchip capillary electrophoresis (CE) with integrated indium tin oxide (ITO) working electrode based on electrochemiluminescence (ECL) detection. This microchip CE-ECL system can be used for the rapid analysis of lincomycin within 40s. Under the optimized conditions, the linear range was obtained from 5 to 100 microM with correlation coefficient of 0.998. The limit of detection (LOD) of 3.1 microM was obtained for lincomycin in the standard solution. We also applied this method to analyzing lincomycin in the urine matrix. The limit of detection of 9.0 microM was obtained. This method can determine lincomycin in the urine sample without pretreatment, which demonstrated that it is a promising method of detection of lincomycin in clinical and pharmaceutical area.  相似文献   

2.
Guihen E  Hogan AM  Glennon JD 《Chirality》2009,21(2):292-298
In this research, a capillary electrophoretic method for the fast enantiomeric resolution of (R,S)-naproxen was investigated. Method development involved variation of applied potential, buffer concentration, buffer pH, and cyclodextrin concentration. The optimum electrophoretic separation conditions were 110 mM sodium acetate run buffer (pH 6.0), 30 mM methyl-beta-cyclodextrin, 20% (v/v) acetonitrile, 25 degrees C. The total length of capillary was 48 cm, (50 microm I.D.) with ultra violet (UV) detection at 232 nm. Using these conditions, the number of theoretical plates was close to one million (896,000/m). The possibility of achieving a fast chiral separation of (R,S)-naproxen on a microchip of 2.5 cm in length was investigated. Complete enantiomeric resolution of naproxen was achieved in less than 1 min, on this microchip platform, with linear imaging UV detection. This system had the advantage of real-time separation monitoring, so that enantiomeric resolution could be visually observed, and high-speed chiral analysis was realized. The microchip electrophoresis (MCE) separation was compared with the capillary electrophoresis (CE) separation with regards to speed, efficiency, separation platform, and precision. This work highlights the potential of CE and MCE in future chiral separations.  相似文献   

3.
Deoxyribonuclease I (DNase I) activity in serum has been shown to be a novel diagnostic marker for the early detection of acute myocardial infarction (AMI). However, the conventional method to measure DNase I activity is time-consuming. In the current study, to develop a rapid assay method for DNase I activity for clinical purposes, a microchip electrophoresis device was used to measure DNase I activity. Because DNase I is an endonuclease that degrades double-stranded DNA endo-nucleolytically to produce oligonucleotides, degradation of the DNA standard caused by DNase I action was detected using microchip electrophoresis. We detected DNase I activity within 10 min. This is the first study to apply microchip electrophoresis for the detection of DNase I activity; furthermore, it seems plausible that reduction of analysis time for DNase I activity could make this novel assay method using microchip electrophoresis applicable in clinical use.  相似文献   

4.
A microchip analytic system that uses a silicon chip with immobilized in microreactor test-system for multiplex analysis of DNA by real-time polymerase chain reaction (real time PCR) was developed and optimized. We suggested the method of immobilization of PCR-components of a test-system, chose the stabilizer, and conducted the optimization of the composition of reaction mixture to achieve permanent stability of a microchip. We conducted optimization of preparation of samples using magnetic sorbent and indicated that, with 2.6 × 104 copies/ml, 60 min are necessary to obtain positive identification including time for preparation of model samples. The abilities of the created system were demonstrated on the example of microchip analysis of samples with different content of DNA, low absolute limits of detection (20 DNA copies in microreactor), and high reproducibility of the analysis.  相似文献   

5.
A homogeneous chemiluminescent immunoassay of thyroxine (T4) enhanced by microchip electrophoresis separation has been developed. The method deployed the competitive immunoreaction of T4 and horseradish peroxidase (HRP)-labeled T4 (HRP-T4) with anti-T4 mouse monoclonal antibody (Ab). HRP-T4 and the HRP-T4-Ab complex were separated and quantified by using microchip electrophoresis (MCE) with chemiluminescence (CL) detection. Highly sensitive CL detection was achieved by means of HPR-catalyzed luminol-H2O2 reaction. Due to the effective MCE separation, the CL analytical signal was less prone to sample matrix interference. Under the selected assay conditions, the MCE separation was accomplished within 60 s. The linear range for T4 was 5-250 nM with a detection limit of 2.2 nM (signal/noise ratio = 3). The current method was successfully applied for the quantification of T4 in human serum samples. It was demonstrated that the current MCE-CL-enhanced competitive immunoassay was quick, sensitive, and highly selective. It may serve as a tool for clinical analysis of T4 to assist in the diagnosis of thyroid gland functions.  相似文献   

6.
We examined the feasibility of using a two-color time-resolved detection scheme with microdevices for DNA sequencing applications. A home-built dual-color optical-fiber-based time-resolved near-infrared (IR) fluorescence microscope successfully coupled lifetime discrimination with color discrimination, increasing fluorescence multiplexing capabilities. The instrument was constructed by using two pulsed-diode lasers (680/780-nm excitation) and two avalanche photodiodes as the basic building blocks. The data were processed using electronics configured in a time-correlated single-photon counting format. The use of near-IR fluorescence detection greatly simplified the hardware and allowed low detection limits (< 0.1nM). We examined the separation of a single-base tract on a microchip and compared the performance with that of conventional capillary gel electrophoresis. The microchip was fabricated in glass and contained an effective separation length of 7.0 cm. It was found that, without incorporating a solid-phase reversible immobilization cleanup procedure, the calculated lifetime of the dye label on the microchip was longer and the standard deviation was larger than those of the same sample analyzed using capillary electrophoresis. Using cleanup steps, the accuracy and precision of the measurements improved. Lifetimes of four near-IR dyes (AlexaFluor680, IRD700, IRD800, and IRD40) used in this study were determined to be 986 ps (RSD=2.1%), 1551 ps (RSD=1.8%), 520 ps (RSD=3.3%), and 788 ps (RSD=4.9%), respectively, in a microchannel filled with poly(dimethylacrylamide) (POP-6) gel. The lifetimes calculated using maximum likelihood estimators provided favorable precision on the microchip, where small numbers of photocounts were collected. An M13mp18 template was sequenced on the microchip using a two-color two-lifetime format with POP-6 as the sieving polymer. Read lengths of 294 bp with calling accuracies of 90.8 and 83.7% were achieved in each color channel. The relatively low calling accuracy and the short read length resulted primarily from the short separation channel, which yielded low electrophoretic resolution.  相似文献   

7.
The p16 tumor suppressor gene is inactivated by promoter region hypermethylation in many types of tumor. Recent studies showed that aberrant methylation of the p16 gene is an early event in many tumors, especially in lung cancer, and may constitute a new biomarker for early detection and monitoring of prevention trials. We detected tumor-associated aberrant hypermethylation of the p16 gene in plasma and tissue DNA from 153 specimens using a modified semi-nested methylation-specific PCR (MSP) combining plastic microchip electrophoresis or slab gel electrophoresis, respectively. Specimens were from 79 lung cancer patients, 15 abdominal tumor patients, 30 positive controls and 30 negative controls. The results showed that the positive rate obtained by microchip electrophoresis was more than 26.6% higher and the same specificity was kept when compared with slab gel electrophoresis. The microchip electrophoresis can rapidly and accurately analyze the PCR products of methylated DNA and obviously improve the positive rate of diagnosis of cancer patients when compared with gel electrophoresis. This method with the high assay sensitivity might be used for detection of methylation of p16 gene and even to facilitate early diagnosis of cancer patients.  相似文献   

8.
Rapid and accurate detection of plant pathogens in the field is crucial to prevent the proliferation of infected crops. Polymerase chain reaction (PCR) process is the most reliable and accepted method for plant pathogen diagnosis, however current conventional PCR machines are not portable and require additional post-processing steps to detect the amplified DNA (amplicon) of pathogens. Real-time PCR can directly quantify the amplicon during the DNA amplification without the need for post processing, thus more suitable for field operations, however still takes time and require large instruments that are costly and not portable. Microchip PCR systems have emerged in the past decade to miniaturize conventional PCR systems and to reduce operation time and cost. Real-time microchip PCR systems have also emerged, but unfortunately all reported portable real-time microchip PCR systems require various auxiliary instruments. Here we present a stand-alone real-time microchip PCR system composed of a PCR reaction chamber microchip with integrated thin-film heater, a compact fluorescence detector to detect amplified DNA, a microcontroller to control the entire thermocycling operation with data acquisition capability, and a battery. The entire system is 25×16×8 cm3 in size and 843 g in weight. The disposable microchip requires only 8-µl sample volume and a single PCR run consumes 110 mAh of power. A DNA extraction protocol, notably without the use of liquid nitrogen, chemicals, and other large lab equipment, was developed for field operations. The developed real-time microchip PCR system and the DNA extraction protocol were used to successfully detect six different fungal and bacterial plant pathogens with 100% success rate to a detection limit of 5 ng/8 µl sample.  相似文献   

9.
Three-dimensional gel-based microchip allowing simultaneous quantitative detection of total (PSAtot) and free (PSAfree) forms of prostate specific antigen in human serum (in a format "one patient-one biochip") was developed. A method, which doesn't require preliminary construction of calibration curves when performing an assay, was applied for quantitative determination of PSAtot and PSAfree. Gel elements with immobilized antigen (PSA) in different concentration, forming an internal calibration curve, were included in a structure of the microchip, in addition to the elements with immobilized antibodies specific against PSAtot and PSAfree. The specialized software "ImaGelAssay" was used for data processing and interpretation. The sensitivity of the assay performed on biochips was 0.3 ng/ml for PSAtot and 0.2 ng/ml for PSAfree. Variation coefficient for the measurements inside one series of microchips didn't exceed 10%. Correlation coefficient between the results of measurements in human sera obtained on biochips and by the standard ELISA method was 0.988 for PSAtot and 0.987 for PSAfree.  相似文献   

10.
A novel electrochemical detection architecture was investigated for enzyme immunoassay sensors. Microchips with dual-ring working and counter electrodes, and a sensing cavity chamber were made on glass slides. The glass surface of the microchip was coated by 3-aminopropyltriethoxysilane (APTES). Goat IgG, as a example, was covalently captured on APTES-modified glass surfaces through glutaraldehyde (GA) as a cross-linker. Enzyme substrate, p-aminophenyl phosphate (PAPP) was prepared by electrolysis. The enzyme conversion from home-synthetic PAPP to p-aminophenol (PAP) was examined by differential pulse voltammetry (DPV). A competitive inhibition enzyme-linked immunosorbant assay (ELISA) was designed to test the system. Experimental results demonstrate that a detection limit of 118 fg/ml of goat IgG and a dynamic range of 118 fg/ml to 1.18 ng/ml, up to five orders of magnitude could be achieved. Due to its novel architecture design and electronic detection scheme, the method can be used to fabricate portable electrochemical ELISA lab-on-chip systems. The technology could have great potential in clinical diagnostic applications.  相似文献   

11.
A sensitive and selective analytical method for the determination and quantification of endogenous β-galactosidase in crude E. coli cell lysates by immunoprecipitation combined with automated microchip capillary gel electrophoresis (IP-MCGE) with laser-induced fluorescence (LIF) detection was developed. Total cell lysates were derivatized minimally with a fluorescence dye, incubated with anti-β-galactosidase antibodies, and the antigen/antibody complex was precipitated with protein G-coated magnetic beads. After capturing the complex, it was eluted from the beads under denaturing conditions and loaded directly onto a multisample microchip for analysis. The effects of antibody selection and the importance of preclearing steps were studied in detail. For quantification, an external calibration through spiking pure β-galactosidase into E. coli lysate was performed. Recovery rates of immunoprecipitation after spiking experiments and the amount of unknown endogenous β-galactosidase in E. coli lysates were determined. As proof of principle, E. coli cultures grown on nutrition media with several glucose/lactose ratios were analyzed. Differences in the expression level of β-galactosidase could be detected and measured with the developed method. Detected amounts of β-galactosidase in different culture media correlated with the β-galactosidase activities in these cultures.  相似文献   

12.
Protein size separation based on sodium dodecyl sulfate-gel electrophoresis (SDS-GE) requires denaturing, but we propose that denaturing is unnecessary for analysis by microchip electrophoresis (micro-CE). By omitting the protein denaturing process, we achieved not only shortened total analysis time, but also dramatically improved sensitivity without compromising size determination. The detection limit was improved to 0.1 ng/microL under conditions without denaturing and 600 pg (9.0 femtomol) of bovine serum albumin was detectable, which equals levels detectable by Silver stain, although a routine method by microchips in the Coomassie Blue detection level.  相似文献   

13.
Microchip capillary electrophoresis (CE), coupled with indirect fluorescence detection was investigated for estimating the pK(a) values of non-fluorescent compounds. The CE method is based on the differences in electrophoretic mobility of the analyte as a function of the pH of the running buffer. Nine compounds were tested, including several of pharmaceutical importance, with pK(a) values from 10.3 to 4.6. All buffers contained 5-TAMRA as the fluorescent probe for indirect detection. Calculated pK(a) values agreed well with literature values obtained by traditional methods, differing not more than 0.2 from the literature value. The current work on single lane chips demonstrates the principle of microchip CE with indirect detection as a viable method for estimating pK(a) values. However, increased throughput will be required using a multilane chip to enable the approach to be used practically.  相似文献   

14.
A two‐electrode configuration powered by batteries was designed for a microchip capillary electrophoresis–electrochemiluminescence system. A home‐made working electrode for end‐column mode detection and wall‐jet configuration was made up of a platinum wire (0.3 mm diameter) and a quartz capillary (320 µm internal diameter). The platinum wire served as a pseudoreference electrode. The configuration of the detection power supply comprised two D‐size batteries (connected in series), a switch, and an adjustable resistor. The microchip consisted of two layers: the bottom layer was a glass sheet containing injection and separation channels; the upper layer was polydimethylsiloxane block. In order to reduce the loss of electrochemiluminescence signal, a coverslip (0.17 mm thickness) was used as the floor of the detection reservoir. The performance of the system was demonstrated by separation and detection of atropine, anisodamine and proline. The linear response for proline ranged from 5 µm to 100 µm (r = 0.9968), and the limit of detection was 1.0 µm (S/N = 3). The system was further applied to the measurement of atropine in atropine sulfate injection solutions with the limit of detection 2.3 µm . This new system is a potential tool in pharmaceutical analysis. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

15.
A simple microchip device for DNA extraction was constructed based on electrostatic interactions between surface amine groups and DNA. Microchannel was fabricated on silicon wafer by photolithography and coated with 3-aminopropyltriethoxysilane (APTES) or 3-[2-(2-aminoethylamino)-ethylamino]-propyltrimethoxysilane (AEEA) to introduce amine groups on the surface. Determination of the number of surface amine groups and optimization of DNA capture condition were demonstrated to characterize the microchip. Capacities of capturing DNA were approximately 97 ng/cm2 in APTES and 194 ng/cm2 in AEEA modified microchips, respectively. The amount of DNA captured in the microchip increased depending on surface amine density. Furthermore, DNA extraction using amine-coated microchip from whole blood was examined. Quantification of DNA and proteins in washing or eluting fraction indicates that proteins were removed at washing steps and only DNA was effectively eluted by changing alkalinity of buffer from pH 7.5 to 10.6. The amount of DNA extracted from whole blood was approximately 10 ng and its recovery ratio was 27-40%. Performance of PCR for the eluted fraction indicates that DNA extracted from whole blood was well purified using amine-coated microchip.  相似文献   

16.
A microchip method has been developed for massive and parallel thermodynamic analyses of DNA duplexes. Fluorescently labeled oligonucleotides were hybridized with oligonucleotides immobilized in the 100 x 100 x 20 mum gel pads of the microchips. The equilibrium melting curves for all microchip duplexes were measured in real time in parallel for all microchip duplexes. Thermodynamic data for perfect and mismatched duplexes that were obtained using the microchip method directly correlated with data obtained in solution. Fluorescent labels or longer linkers between the gel and the oligonucleotides appeared to have no significant effect on duplex stability. Extending the immobilized oligonucleotides with a four-base mixture from the 3'-end or one or two universal bases (5-nitroindole) from the 3'- and/or 5'-end increased the stabilities of their duplexes. These extensions were applied to increase the stabilities of the duplexes formed with short oligonucleotides in microchips, to significantly lessen the differences in melting curves of the AT- and GC-rich duplexes, and to improve discrimination of perfect duplexes from those containing poorly recognized terminal mismatches. This study explored a way to increase the efficiency of sequencing by hybridization on oligonucleotide microchips.  相似文献   

17.
汪维鹏  周国华 《遗传》2009,31(2):219-224
文章以微流控芯片电泳为检测平台, 建立了一种基于DNA适配器连接介导的多重等位基因特异性扩增同时测定多个单核苷酸多态性(SNP)位点的方法。以白细胞介素1β(IL1B)基因中的7个SNP位点(794C>T、1274C>T、2143T>C、2766T>del、3298G>A、5200G>A和5277C>T)为检测对象, 通过PCR预扩增得一段含该7个待测SNP位点的长片段; 用限制性内切酶MboⅠ将其消化成短片段, 再与DNA适配器(adapter)相连; 以连接产物为模板, 在两管中分别用7条等位基因特异性引物和一条公用引物进行7重等位基因特异性扩增; 最后用微流控芯片电泳法分离等位基因特异性扩增产物, 根据两管扩增产物的芯片电泳图谱中扩增片段的大小判断SNP的类型。采用本法成功测定了48名健康中国人的IL1B基因上的7个SNP位点, 与聚合酶链反应-限制性片段长度多态性法(PCR-RFLP)和测序法测定结果完全一致。本法结果准确, 可用于同时测定多个SNP位点; 以微流控芯片电泳作为检测平台, 分析速度快, 样品需要量少; 借助于自制筛分凝胶和重复使用芯片, 使得SNP分析成本大大降低。  相似文献   

18.
We have developed a rapid assay for single nucleotide polymorphism (SNP) detection that utilizes electronic circuitry on silicon microchips. The method was validated by the accurate discrimination of blinded DNA samples for the complex quadra-allelic SNP of mannose binding protein. The microchip directed the transport, concentration, and attachment of amplified patient DNA to selected electrodes (test sites) creating an array of DNA samples. Through control of the electric field, the microchip enabled accurate genetic identification of these samples using fluorescently labeled DNA reporter probes. The accuracy of this approach was established by internal controls of dual labeled reporters and by using mismatched sequences in addition to the wild-type and variant reporter sequences to validate the SNP-genotype. The ability to customize this assay for multiple genes has advantages over other existing approaches.  相似文献   

19.
Anchored multiplex amplification on a microelectronic chip array   总被引:6,自引:0,他引:6  
We have developed a method for anchored amplification on a microchip array that allows amplification and detection of multiple targets in an open format. Electronic anchoring of sets of amplification primers in distinct areas on the microchip permitted primer-primer interactions to be reduced and distinct zones of amplification created, thereby increasing the efficiency of the multiplex amplification reactions. We found strand displacement amplification (SDA) to be ideal for use in our microelectronic chip system because of the isothermal nature of the assay, which provides a rapid amplification system readily compatible with simple instrumentation. Anchored SDA supported multiplex DNA or RNA amplification without decreases in amplification efficiency. This microelectronic chip-based amplification system allows multiplexed amplification and detection to be performed on the same platform, streamlining development of any nucleic acid-based assay.  相似文献   

20.
In this paper, we show an integrated complementary metal oxide semiconductor (CMOS)-based microchip system with capillary array electrophoresis (CAE) for the detection of bacterial pathogen amplified by polymerase chain reaction (PCR). In order to demonstrate the efficacy of PCR reaction for the heat-labile toxin producing enterotoxigenic Escherichia coli (E. coli), which causes cholera-like diarrhea, 100 bp DNA ladders were injected along with the PCR product. Poly(vinylpyrrolidone) (PVP) was used as the separation medium and provided separation resolution which was adequate for the identification of PCR product. The miniaturized integrated CMOS microchip system with CAE has excellent advantages over conventional instrumental systems for analysis of bacterial pathogens such as compactness, low cost, high speed, and multiplex capability. Furthermore, the miniaturized integrated CMOS microchip system should be compatible with a variety of microfabricated devices that aim at more rapid and high-throughput analysis.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号