首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Tantalum, as a potential metallic implant biomaterial, is attracting more and more attention because of its excellent anticorrosion and biocompatibility. However, its significantly high elastic modulus and large mechanical incompatibility with bone tissue make it unsuitable for load-bearing implants. In this study, porous tantalum coatings were first successfully fabricated on titanium substrates by vacuum plasma spraying (VPS), which would exert the excellent biocompatibility of tantalum and alleviate the elastic modulus of tantalum for bone tissue. We evaluated cytocompatibility and osteogenesis activity of the porous tantalum coatings using human bone marrow stromal cells (hBMSCs) and its ability to repair rabbit femur bone defects. The morphology and actin cytoskeletons of hBMSCs were observed via electron microscopy and confocal, and the cell viability, proliferation and osteogenic differentiation potential of hBMSCs were examined quantitatively by PrestoBlue assay, Ki67 immunofluorescence assay, real-time PCR technology and ALP staining. For in vivo detection, the repaired femur were evaluated by histomorphology and double fluorescence labeling 3 months postoperation. Porous tantalum coating surfaces promoted hBMSCs adhesion, proliferation, osteogenesis activity and had better osseointegration and faster new bone formation rate than titanium coating control. Our observation suggested that the porous tantalum coatings had good biocompatibility and could enhance osseoinductivity in vitro and promote new bone formation in vivo. The porous tantalum coatings prepared by VPS is a promising strategy for bone regeneration.  相似文献   

2.
目的:通过建立兔股骨缺损的动物实验模型,对采用等温化学气相沉积法和等离子喷涂技术所制备的石墨化炭/炭复合材料+羟基磷灰石涂层(C/C+HA)复合骨植入材料进行骨植入实验的的生物相容性进行评价,探索该复合材料作为植入机体骨组织的可行性依据.方法:采用骨科钻在实验动物股骨髁上钻孔的方法建立骨缺损的动物实验模型,将待研究比较的实验材料分别植入实验动物的股骨髁内,持续观察8周,在术后第2、4、8周时应用X线照片、组织学染色和扫描电镜技术,分别观察所研究材料在机体内对骨缺损愈合及其对机体的影响,进行组间比较和相关性分析.结果:石墨化炭/炭复合材料+羟基磷灰石涂层(C/C+HA)复合骨植入材料的骨植入实验生物相容性良好,材料与骨组织结合牢固,界面中成骨细胞生长明显,且炭颗粒脱落现象少,未见炎症细胞浸润.植入动物体内的材料在植入期未引起机体局部的炎症浸润反应且表面脱落的碳颗粒在机体组织中也未引起局部严重的炎症反应.在实验动物植入材料后的连续8周观察期中,组织学观察显示:表面涂有HA的炭/炭复合材料对骨组织形态改建上表现良好,其与骨组织接界处所形成的纤维结缔组织膜层厚度明显比未涂HA的材料要小,与骨组织结合更为紧密和牢固;碳颗粒出现脱落游离的现象明显减少.结论:在炭/炭复合材料表面涂以HA生物涂层对骨的形态改建和促进骨小梁生长等方面具有良好的作用,是一种具有发展潜力的骨修复材料.  相似文献   

3.
The novel non-thermal CoBlast process has been used recently to create a hydroxyapatite coating on metallic substrates with improved biological response compared to an uncoated implant. In this study, we compared the biological effect of coatings deposited by this process and the industrial standard technique - plasma-spray. Physicochemical properties of these two coatings have been found to be significantly different in that CoBlast HA is less rough but more hydrophilic than the plasma-spray HA as evidenced by data obtained from profilometry and goniometry. Mesenchymal stem cell attachment and adhesion are enhanced on CoBlast HA. Analysis by a combination of EDX and ICP suggests that the higher crystallinity retained by the CoBlast HA result in slower coating dissolution. Detailed in vitro evaluation reveals that plasma-spray HA might induce slightly faster cell proliferation and earlier osteogenic differentiation, but CoBlast HA becomes equivalent to it by the late osteogenic stage. PCR array facilitated the identification of differentially regulated genes involved in various functional aspects of in vitro osteogenesis by the CoBlast HA coating. The expression level of the functional protein products of these genes are in agreement with the PCR data. Coating metallic screws with HA significantly improves the in vivo osseointegration. By measuring of removal force using torque measurement instrument and analyzing the patterns found in X-ray images it is demonstrated that the two HA coatings elicit comparable osseointegration. Using simulated impaction model, CoBlast HA is shown to maintain better performance in cell attachment and mineralization than plasma-spray HA, especially following significant impactions. This might indicate a potentially greater osteoconductivity of CoBlast HA coating in shear-stress associated surgical applications. Collectively, it was demonstrated that CoBlast HA is an effective alternative to plasma-spray HA coating and a promising replacement for specialized surgical applications.  相似文献   

4.
王健  吴松  陈腾飞  朱东波  王靖  周天宝 《生物磁学》2011,(14):2615-2619
目的:通过建立兔股骨缺损的动物实验模型,对采用等温化学气相沉积法和等离子喷涂技术所制备的石墨化炭/炭复合材料+羟基磷灰石涂层(C/C+HA)复合骨植入材料进行骨植入实验的的生物相容性进行评价,探索该复合材料作为植入机体骨组织的可行性依据。方法:采用骨科钻在实验动物股骨髁上钻孔的方法建立骨缺损的动物实验模型,将待研究比较的实验材料分别植入实验动物的股骨髁内,持续观察8周,在术后第2、4、8周时应用X线照片、组织学染色和扫描电镜技术,分别观察所研究材料在机体内对骨缺损愈合及其对机体的影响,进行组间比较和相关性分析。结果:石墨化炭/炭复合材料+羟基磷灰石涂层(C/C+HA)复合骨植入材料的骨植入实验生物相容性良好,材料与骨组织结合牢固,界面中成骨细胞生长明显,且炭颗粒脱落现象少,未见炎症细胞浸润。植入动物体内的材料在植入期未引起机体局部的炎症浸润反应且表面脱落的碳颗粒在机体组织中也未引起局部严重的炎症反应。在实验动物植入材料后的连续8周观察期中,组织学观察显示:表面涂有HA的炭/炭复合材料对骨组织形态改建上表现良好,其与骨组织接界处所形成的纤维结缔组织膜层厚度明显比未涂HA的材料要小,与骨组织结合更为紧密和牢固;碳颗粒出现脱落游离的现象明显减少。结论:在炭/炭复合材料表面涂以HA生物涂层对骨的形态改建和促进骨小梁生长等方面具有良好的作用,是一种具有发展潜力的骨修复材料。  相似文献   

5.
The application of synthetic materials for bone replacement is now well established, but it is recognized that mechanical compatibility, as well as biocompatibility, of the tissue and implant is required if stress shielding and consequent bone resorption is to be avoided at areas of fixation. The development of materials analogous to the natural tissue for longer term implantation is discussed, with particular reference to hydroxyapatite reinforced polymers.  相似文献   

6.
Friction corrosion may appear between different implant components or between implant and hard tissue. The sliding micro movements induce fretting wear corrosion and have been recently reported as a cause of joint prostheses failure. A surface coating is desirable, that retains the mechanical properties of the substrate, offers good biocompatibility and improves the fretting corrosion resistance. In this study it could be demonstrated that tantalum and niobium coatings fulfill the requirements. On titanium substrates the coating decreases the abrasion against PMMA, an orthopedic relevant material. Furthermore, in the case of medical steel substrates the biocompatibility and the corrosion properties are improved. The better abrasion-resistance is minimizing the release of allergological critical particles like nickel and chromium.  相似文献   

7.
Ideal coatings for orthopedic implants should be able to induce excellent osseointegration with host bone tissue, which requires good osteogenic responses and limited inflammatory reactions. Cerium oxide (CeO2) ceramics have anti-oxidative properties and can be used to decrease mediators of inflammation, making them attractive for biomedical application. In this study, two kinds of CeO2 incorporated calcium silicate coatings (CS-10Ce and CS-30Ce) were prepared via plasma spraying technique, and the effects of CeO2 addition on the responses of bone mesenchymal stem cells (BMSCs) and RAW264.7 macrophages were evaluated. The CS-10Ce and CS-30Ce coatings were characterized by X-ray diffraction, scanning electron microscopy, and X-ray photoelectron spectroscopy. An increase in CeO2 content in the coatings resulted in enhanced chemical stability and better BMSCs osteogenic behaviors in terms of cell adhesion, proliferation, ALP activity, and mineralized nodule formation. With respect to either ZrO2-added or unmodified CS coating, the CS-30Ce coating elicited higher effects on the macrophages, suppressing the gene expressions of pro-inflammatory (M1) markers (CCR7, IL-6, and TNF-α), while upregulating the expressions of anti-inflammatory (M2) markers (CD206, IL-1ra, and IL-10); moreover, it could also increase the expression of osteoinductive molecules (BMP2 and TGF-β1) by the macrophages. The results suggested that the regulation of BMSCs behaviors and macrophage-mediated responses at the coating’s surface was related to CeO2 incorporation. The incorporation of CeO2 in CS coatings can be a valuable strategy to promote osteogenic responses and mitigate inflammatory reactions.  相似文献   

8.
We have incorporated bisphosphonates and antibiotics simultaneously into a biomimetic hydroxyapatite implant coating aiming to use the interaction between drug-molecules and hydroxyapatite to enable local release of the two different substances to obtain a dual biological effect. A sustained release over for 43 h of antibiotics (cephalothin) was achieved without negative interference from the presence of the bisphosphonate (clodronate) which, in turn, successfully bonded to the coating surface. To our knowledge, this is the first study that indicates the possibility to simultaneously incorporate both antibiotics and bisphosphonates to an implant coating, a strategy that is believed to improve implant stability and reduce implant-related infections.  相似文献   

9.
A novel method is described for the non line-of-sight coating of hydroxyapatite onto polyurethane reticulated foam and titanium discs. This utilises a biofilm of Serratia sp. NCIMB 40259 which, when challenged with a solution containing calcium chloride and phosphatase substrate, manufactures biofilm-bound material identified as hydroxyapatite by X-ray powder diffraction analysis. Non-invasive magnetic resonance imaging was used to visualize the biofilm coating throughout the foam labyrinth and to measure the thickness of the film within reticulated foam cubes in situ. The film developed within the cube matrices was similar to that measured on the surface of a glass slide. Using LaPO(4) deposition as a model system the metallised biofilm was visualised in two-dimensional slices throughout three-dimensional images acquired by magnetic resonance imaging. A similar encrustation of hydroxyapatite on the surface of biofilm grown on titanium discs was confirmed by scanning electron microscopy. Potential applications for bio-hydroxyapatite as possible bone implant precursors are discussed.  相似文献   

10.
The objective of the present study is to evaluate bone loss at implant abutments coated with a soda-lime glass containing silver nanoparticles subjected to experimental peri-implantitis. Five beagle dogs were used in the experiments, 3 implants were installed in each quadrant of the mandibles. Glass/n-Ag coted abutments were connected to implant platform. Cotton floss ligatures were placed in a submarginal position around the abutment necks and the animals were subject to a diet which allowed plaque accumulation, and after 15 weeks the dogs were sacrificed. Radiographs of all implant sites were obtained at the beginning and at the end of the experimentally induced peri-implantitis. The radiographic examination indicated that significant amounts of additional bone loss occurred in implants without biocide coating, considering both absolute and relative values of bone loss. Percentages of additional bone loss observed in implants dressed with a biocide coated abutment were about 3 times lower (p<0.006 distal aspect; and p<0.031 at mesial aspect) than the control ones. Within the limits of the present study it seems promising the use of soda-lime glass/nAg coatings on abutments to prevent peri-implant diseases.  相似文献   

11.
In a dental implant system, the value of stress and its distribution plays a pivotal role on the strength, durability and life of the implant–bone system. A typical implant consists of a Titanium core and a thin layer of biocompatible material such as the hydroxyapatite. This coating has a wide range of clinical applications in orthopedics and dentistry due to its biocompatibility and bioactivity characteristics. Low bonding strength and sudden variation of mechanical properties between the coating and the metallic layers are the main disadvantages of such common implants. To overcome these problems, a radial distributed functionally graded biomaterial (FGBM) was proposed in this paper and the effect of material property on the stress distribution around the dental implant–bone interface was studied. A three-dimensional finite element simulation was used to illustrate how the use of radial FGBM dental implant can reduce the maximum von Mises stress and, also the stress shielding effect in both the cortical and cancellous bones. The results, of course, give anybody an idea about optimized behaviors that can be achieved using such materials. The finite element solver was validated by familiar methods and the results were compared to previous works in the literature.  相似文献   

12.
Metallic materials are commonly used for load-bearing implants and as internal fixation devices. It is customary to use austenitic stainless steel, especially surgical grade type 316L SS as temporary and Ti alloys as permanent implants. However, long-term, poor bonding with bone, corrosion, and release of metal ions, such as chromium and nickel occur. These ions are powerful allergens and carcinogens and their uncontrolled leaching may be avoided by surface coatings. Therefore, bioactive glasses (BGs) became a vital biomedical material, which can form a biologically active phase of hydroxycarbonate apatite on their surface when in contact with physiological fluids. To reduce the high coefficient of friction and the brittle nature of BGs, polymers are normally incorporated to avoid the high-temperature sintering/densification of ceramic-only coatings. For medical application, electrophoretic deposition (EPD) is now used for polymer (organic) and ceramic (inorganic) components at room temperature due to its simplicity, control of coating thickness and uniformity, low cost of equipment, ability to coat substrates of intricate shape and to supply thick films in composite form, high purity of deposits as well as no phase transformation during coating. Although extensive research has been conducted on polymer/inorganic composite coatings, only some studies have reported multifunctional properties, such as biological antibacterial activity, enhanced cell adhesion, controlled drug release ability, and mechanical properties. This review will focus on biodegradable coatings, including zien, chitosan, gelatin, cellulose loaded with antibacterial drugs/metallic ions/natural herbs on biostable substrates (PEEK/PMMA/PCL/PLLA layers), which have the potential of multifunctional coating for metallic implants.  相似文献   

13.
The surface state of titanium implants modulates bone response and implant anchorage. This evidence brought implant manufacturers to switch from the standard surface refinements and implement new surface treatments for more bone apposition and enhanced interfacial strength measured by removal torque or push-out tests. Anodic plasma-chemical treatment of implant surfaces is a cost-effective process to modify surface topography and chemistry. This technique is used for structuring connected with a coating of implant surfaces. The aim of our investigations, here, is to texture the implant surface in the nanoscale without coating. Ti disks with different mechanical pre-treatment (grinded, glass blasted) were used as substrate. Micro-plasma texturing was carried out in an aqueous electrolyte. By applying a pulsed DC voltage to the specimen, micro-plasma discharge was generated in the thin steam film between immersed specimen and electrolyte. The electrical process parameter current density was varied. The micro-plasma textured Ti surfaces were characterised optically by SEM and electrochemically by CV- (for testing the corrosion parameters), CA- (to give the enlargement of the real surface) and EIS-measurement in range of 100 kHz-100 microHz. We found that the initial structure of the material surface has small or no influence on the results of the micro-plasma treatment. The properties of the thick oxide layer resulting from the plasma process are influenced by electrical process parameters. After removal of the thick oxide layer a fine, micro- and nanoscaled surface structure of the titanium remains.  相似文献   

14.
We used a geometrically simplified finite element model to investigate load transfer between a porous coated hip endoprosthesis and a femur. Assuming both rigidly bonded and nonlinear interfaces, we analyzed fully and partially coated stems that had coatings of different elastic moduli. Our results indicate that maximum values for relative motion in the interface between bone and implant occur for implants with the same elastic modulus as compact bone. By comparison, interface motion is reduced by about half for Co-Cr-Mo alloy stems. We also showed that the elastic modulus of the porous coating had only a small influence on bone stresses.  相似文献   

15.
Ideal orthopedic coatings should trigger good osteogenic response and limited inflammatory response. The cerium valence states in ceria are associated with their anti-oxidative activity and anti-inflammatory property. In the study, we prepared two kinds of plasma sprayed CeO2 coatings with different Ce4+ concentrations to investigate the effects of Ce valence states on the response of bone mesenchymal stem cells (BMSCs) and macrophage RAW264.7. Both the coatings (CeO2-A and CeO2-B) were characterized via XRD, SEM, and X-ray photoelectron spectroscopy. The CeO2 coatings enhanced osteogenic behaviors of BMSCs in terms of cellular proliferation, alkaline phosphatase (ALP) activity and calcium deposition activity in comparison with the Ti substrate. In particular, the CeO2-B coating (higher Ce4+ concentration) elicited greater effects than the CeO2-A coating (higher Ce3+ concentration). RT-PCR and western blot results suggested that the CeO2-B coating promoted BMSCs osteogenic differentiation through the SMAD-dependent BMP signaling pathway, which activated Runx2 expression and subsequently enhanced the expression of ALP and OCN. With respect to either CeO2-A coating or Ti substrate, the CeO2-B coating exerted greater effects on the macrophages, increasing the anti-inflammatory cytokines (IL-10 and IL-1ra) expression and suppressing the expression of the pro-inflammatory cytokines (TNF-α and IL-6) and ROS production. Furthermore, it also upregulated the expression of osteoinductive molecules (TGF-β1 and BMP2) in the macrophages. The regulation of cerium valence states at plasma sprayed ceria coatings can be a valuable strategy to improve osteogenic properties and alleviate inflammatory response.  相似文献   

16.
Maritime hydraulic components are often exposed to harsh environmental conditions which can lead to accelerated deterioration, reduced function, equipment failure and costly repair. Two leading causes of maritime hydraulic failure are biofouling accumulation and corrosion. This study examined the antifouling performance of three candidate replacement high velocity oxygen fuel (HVOF) coatings relative to the performance of the current baseline air plasma spray (APS) ceramic coating for protection of hydraulic actuators. Following 20 weeks immersion at tropical and temperate field exposure sites, the control APS ceramic accumulated significantly greater levels of biofouling compared to the HVOF coatings. More specifically, the magnitude of growth of real-world nuisance hard fouling observed on in-service hydraulic components (eg calcareous tubeworms and encrusting bryozoans) was significantly greater on the APS ceramic relative to HVOF coatings. Possible explanations for the observed patterns include differences in surface topography and roughness, the electrochemical potential of the surfaces and the colour/brightness of the coatings.  相似文献   

17.
To assess the potential of a porous hydroxyapatite matrix to serve as a bone graft substitute, bilateral 15 X 20 mm craniectomy defects were reconstructed in 17 dogs with blocks of implant and split-rib autografts. Specimens were retrieved at 3, 6, 12, 24, and 48 months, and undecalcified sections were prepared for microscopy and histometry. The implant and graft cross-sectional areas did not change with time, documenting their equivalent ability to maintain cranial contour. Bone ingrowth extended across the implant from one cranial shelf to the other in 15 specimens. Little apparent bone ingrowth was seen in most graft specimens. Two implants and three grafts were nonunited, possibly due to lack of fixation or the orientation of the histology sections. The implant specimens were composed of 39.3 percent hydroxyapatite matrix, 17.2 percent bone ingrowth, and 43.5 percent soft-tissue ingrowth. The graft specimens were composed of 43.7 percent bone and 56.3 percent soft tissue. This study supported the thesis that a porous hydroxyapatite matrix may function in part as a bone graft substitute. The brittle hydroxyapatite matrix undoubtedly became stronger with bone ingrowth, but the degree of cranial protection achieved was not measured in this study. The size of the cranial defect used in this study did not permit estimation of the distance over which bone ingrowth may be reliably expected. There remains a need for greater understanding of the causes of nonunion, the extent of predictable ingrowth depth, and the strength of the resultant implant-bone composite.  相似文献   

18.
Experimental hydroxyapatite cement cranioplasty.   总被引:27,自引:0,他引:27  
Hydroxyapatite cement is a calcium phosphate-based material that when mixed with water forms a dense paste that sets within 15 minutes and isothermically converts in vivo to a microporous hydroxyapatite implant. This cement was used to reconstruct bilateral 2.5-cm-diameter full-thickness critical-sized parietal skull defects in six cats. One side was reconstructed with 100 percent hydroxyapatite cement, and the other with a mixture of 50 percent hydroxyapatite cement and 50 percent ground autogenous bone by weight. These animals were sacrificed at 6 and 12 months after implantation. Positive and negative controls also were prepared. The anatomic contour of the soft tissue overlying all hydroxyapatite cement implants was well maintained, there were no wound infections or structural failures, and the implants were well tolerated histologically. None of the negative (unreconstructed) control defects was completely filled with repair bone, and all positive (methyl methacrylate) controls demonstrated foreign-body giant-cell formation and fibrous encapsulation of the implants. Examination of decalcified and undecalcified sections revealed progressive but variable replacement of the cement by new bone and soft tissue without a change in the shape or volume of the hydroxyapatite cement-reconstructed areas. New bone comprised 77.3 and 64.7 percent of the tissue replacing the hydroxyapatite cement and hydroxyapatite cement-bone implants, respectively. Replacement of the hydroxyapatite cement implants by new bone is postulated to occur by a combination of osteoconduction and implant resorption. These results indicate that further experimental research leading to the possible application of hydroxyapatite cement for full-thickness calvarial defect reconstruction in humans is warranted.  相似文献   

19.
Non-conventional ceramic-based composite coatings were fabricated by air plasma spraying in order to evaluate their microstructural and electromagnetic properties. Different chromia-based formulations were selected and prepared in the form of feedstock materials for the fabrication of samples having an average thickness of about 3 mm. Waveguide testing was performed on the deposited coatings and most interesting results are reported and commented. Despite the complex formulation of investigated materials, as compared with standard materials for thermal spraying, it has been evidenced as plasma spraying can represent an interesting technique to produce functionalized surfaces with tailored electromagnetic properties, adding new potential application areas to the well-known fields where this technology is already present.  相似文献   

20.
目的:评价骨诱导磷酸钙生物陶瓷(BAMOICPC)与可吸收胶原膜(BME-10X医用胶原膜)在牙种植体周围骨缺损中的修复能力。方法:在兔股骨上植入羟基磷灰石涂层BLB种植体,然后在其侧壁制造高4 mm、宽3 mm、深2 mm的骨缺损。对照组为单纯侧壁骨缺损,实验A组骨缺损区仅覆盖BME-10X膜,B组骨缺损区植入BAMOICPC,C组骨缺损区植入BAMOICPC并加盖BME-10X膜。于术后6个月取带种植体的骨段,通过HE染色和扫描电镜(SEM)分析。结果:对照组骨缺损区种植体表面见纤维包裹,实验A组骨缺损边界区少许骨质移行覆盖,实验B组下半部分缺损区新生骨覆盖。C组新生骨完全覆盖骨缺损区,且较B组硬度高,扫描电镜见与种植体结合更紧密。组织学观察B、C两实验组新生骨均可见比较成熟的哈弗氏管系统。结论:骨诱导磷酸钙生物陶瓷BAMOICPC是一种较理想的骨替代材料,联合运用胶原膜修复种植体周骨缺损效果佳。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号