首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
An assistive device is designed to accommodate the special needs of disability that can help people with physical, mental or cognitive challenges go through their day-to-day activities with less difficulty. An assistive device usually provide alternatives to functional limitations imposed by the client's disorder, and thereby minimising rehabilitation costs. It is therefore important to know about how assistive technology will function in all the possible aspects of such disabilities and impairements. When designing a technical device, particularly in conjunction with the target user group, ergonomic issues are therefore important to find out the extent to which an assistive device is convenient or not, and to check the quality performance of assistive technology. Since the question of the match or mismatch of an assistive device and a disabled person requires much attention, it is therefore suggested that paying attention on how an assistive device be ergonomically designed and developed is important. Ergonomic applications are to be applied for increasing motivation of prospective customers through innovative performance of AT. The authors believe that there are opportunities in ergonomic applications to manufacture an assistive device as unique, cost saving, and allows less exertation and reduces energy consumption when it is used. Hence this paper highlights human factors and/or ergonomics consideration in the process of design and development of assistive devices synchronising with gerontechnological research and development aiming to emphasise user's requirement.  相似文献   

2.
An all-glass device sultable for the oxido-reductive titrations of air-sensitive compounds is deseribed. The device has a provision for monltoring the optical spectrum and for sampling the reaction mixture with direct transfers of the sample into electron-paramagnetic resonance sample tubes. The performance of the device is evaluated and an example of its use is given.  相似文献   

3.
Ventricular oversensing in patients with defibrillators is an infrequent but deleterious condition. We report a patient with a cardiac resynchronization–defibrillation device that presented with hyperkalemia and syncope. Device interrogation revealed ventricular double-counting within the QRS of a slow ventricular tachycardia, resulting detection of the slow ventricular tachycardia in the ventricular fibrillation zone, and delivery of an effective therapy, below device programmed detection rate. This case of defibrillator inappropriate detection emphasizes the relevance of device electrogram interrogation in order to minimize inappropriate therapies.  相似文献   

4.
This paper presents a method and a device to position and displace cells. The cells are suspended in a fluid layer trapped between the device and an arbitrary surface such as an object slide or a wafer. The device vibrates at ultrasonic frequencies causing a pressure field in the fluid layer. This pressure field results in a force-field capable of positioning cells. Depending on the way in which the device is excited a 2-D or 3-D force-field can be generated, positioning the cells in lines or points respectively. Furthermore, it is possible to subsequently displace the cells with micrometer accuracy. This has been demonstrated using HL60 and MCF10A cells, and can be achieved without causing damage to the cells.  相似文献   

5.
The construction and use of an electrically operated closure device, together with a control system, for securing samples from a non-inflammable atmosphere is described. An outline of the device for use with a low temperature steam-formaldehyde (LTSF) sterilizer is given.  相似文献   

6.
Nucleic acid purification using microfabricated silicon structures   总被引:9,自引:0,他引:9  
A microfluidic device has been designed, fabricated and tested for its ability to purify bacteriophage lambda DNA and bacterial chromosomal DNA, a necessary prerequisite for its incorporation into a biosensor. This device consists of a microfabricated channel in which silica-coated pillars were etched to increase the surface area within the channel by 300-600%, when the etch depth is varied from 20 to 50 microm. DNA was selectively bound to these pillars in the presence of the chaotropic salt guanidinium isothiocyanate, followed by washing with ethanol and elution with low-ionic strength buffer. Positive pressure was used to move solutions through the device, removing the need for centrifugation steps. The binding capacity for DNA in the device was approximately 82 ng/cm2 and on average, 10% of the bound DNA could be purified and recovered in the first 50 microl of elution buffer. Additionally, the device removed approximately 87% of the protein from a cell lysate. Nucleic acids recovered from the device were efficiently amplified by the polymerase chain reaction suggesting the utility of these components in an integrated, DNA amplification-based biosensor. The miniaturized format of this purification device, along with its excellent purification characteristics make it an ideal component for nucleic acid-based biosensors, especially those in which nucleic acid amplification is a critical step.  相似文献   

7.
A mechanical device for monitoring the diel activity pattern of small burrowing mammals under natural conditions is described. The device has been used to estimate the time spent by the Indian gerbil, Tatera indica indica Hardwicke in foraging above ground and in an underground nest which is a part of the device. Activity patterns recorded with this device have confirmed observations that Tatera i, indica is nocturnal. The average time spent by this rodent outside the nest during an eight day study period was 318 min/24h. These rodents are generally active between 1900–0300 hrs, apparently with two peaks of activity, one between 2100–2200 hrs and the other between 0100–0200 hrs.  相似文献   

8.
Stereotactic radiosurgery is a method for focused irradiation of intracranial lesions. Linac-based radiosurgery is currently performed by two techniques: couch mounted and pedestal mounted. In the first technique a device is required to affix the patient's head to the couch and neoreover to translate it accurately. Structure of such a device constructed by the authors plus acceptance test performed for evaluation is described in the article.A head docking device has been designed and constructed according to geometry of linac's couch and also desired functions. The device is cornpletely made from aluminum and consists of four major components: attachment bar, lower structure with four moveing accuracy mechanical stability and isocentric accuracy were assessed in the frame of acceptance test.Translating accuracy, mechanical stability and isocentric accuracy were found to be respectively: 1 mm, 1.64 mm and 3.2 mm with accuracy of 95%.According to AAPM report no. 54, a head docking device should translate head with an accuracy of 1 mm; this recommendation has been met. Moreover, we have demonstrated that the isocentric accuracy and mechanical stability of the device are sufficient that the device on confidently be used in stereotactic treatment.  相似文献   

9.
Background. Due to the shortage of donor hearts, mechanical circulatory support is increasingly being used as a bridge to transplantation. In order to allow for more widespread use of ventricular assist devices it is mandatory that patients are not continuously hospitalised. We present the results of our experience with patients with end-stage heart failure, discharged from hospital after implantation of a ventricular assist device and followed in an outpatient setting. Methods. After an intensive training and education programme, focusing on the management of the percutaneous driveline and instructions on how to handle in case of an alarm or malfunction of the device, patients were discharged. They were followed in the outpatient department. All regular and unplanned visits were registered, including readmissions. Results. Twenty-seven patients treated with a ventricular assist device were discharged from hospital. There were 37 extra visits, of these, 27 were device related resulting in 21 readmissions (0.78/patient). We treated eight infectious episodes in four patients, all device related. Furthermore seven thromboembolic episodes occurred in four patients. One patient died because of multiorgan failure seven weeks after he was readmitted with an urosepsis. In our experience of 11.4 patient years at home while on the device, only 5% of the time was spent in hospital for complications. In comparison with patients on an assist device who stayed in hospital until transplantation, there were no more complications. Conclusion. This study demonstrates that patients with end-stage heart failure, treated with a ventricular assist device, can be safely discharged from hospital, with an acceptable rate of readmissions. It results in a fair quality of life, with a high degree of independence of the patient. (Neth Heart J 2007; 15:45-50.)  相似文献   

10.
Cognitive enrichment aims to provide animals with opportunities to use their cognitive skills and to promote behaviors associated with positive wellbeing. Cooperation in mammals has been recorded during various behavioral contexts such as hunting, mating, playing, and parental care. Coordinated activity, often with some level of problem-solving action included, is required during cooperation. To investigate dolphins’ ability for collaborative problem-solving, an enrichment device was introduced to two adult male Indo-Pacific bottlenose dolphins (Tursiops aduncus). The device contained fish and ice and was designed to be opened by simultaneously pulling on both ends. After repeated presentation, it became apparent that only one dolphin had active interest in the device. To facilitate opportunities for problem-solving by this individual, an alternative collaborator, a human partner, was provided. Still, both dolphins had access to the device throughout the entire experiment. After the first opening, the same dolphin was highly successful in collaborating with the human in both joined (93%) and delayed (100%) partner conditions. The device provided a novel opportunity for the dolphin to use his cognitive skills. Even though only one dolphin participated actively, both dolphins showed varying degrees of interest to the device throughout the study. Both dolphins spent an average of 48% and 16% of their time, respectively, with the device, which resulted in a significant decrease in their other two most frequently observed behaviors: swimming and poolside observation. As a novel cognitive challenge, the device may be considered as a type of cognitive enrichment.  相似文献   

11.
Measuring the energy intake (kcal) of a person in day-to-day life is difficult. The best laboratory tool achieves 95?% accuracy on average, while tools used in daily living typically achieve 60-80?% accuracy. This paper describes a new method for measuring intake via automated tracking of wrist motion. Our method uses a watch-like device with a micro-electro-mechanical gyroscope to detect and record when an individual has taken a bite of food. Two tests of the accuracy of our device in counting bites found that our method has 94?% sensitivity in a controlled meal setting and 86?% sensitivity in an uncontrolled meal setting, with one false positive per every 5?bites in both settings. Preliminary data from daily living indicates that bites measured by the device are positively related to caloric intake illustrating the potential of the device to monitor energy intake. Future research should seek to further explore the relationship between bites taken and kilocalories consumed to validate the device as an automated measure of energy intake.  相似文献   

12.
ABSTRACT. An inexpensive, portable device which allows measurement of electroantennogram (EAG) maximum amplitudes with a voltmeter instead of an oscilloscope is described. Potential advantages of the device include more rapid recording, low-cost construction of additional EAG recording systems for a laboratory with several users, and portability allowing studies in the field and occasional bench top use. The device is intended for use in conventional EAG recording, where EAG signals with rapid depolarizations are being measured, and where the maximum amplitude of the EAG signal is the only parameter of interest.  相似文献   

13.
The use of radiofrequency as a means of synchronization and stimulation does not necessitate an external lead, and thus has allowed the construction of an implantable device for long-term treatment of reentry tachycardias. The device is used along with Amiodarone therapy and can be triggered by the patient himself.  相似文献   

14.
This paper describes the construction and performance of a simple pressure sensing device with a continuous electrical output. It was constructed utilizing a commercially available transducer, an electropneumatic sensor capsule and a 1 m long tube. The transducer used was a piezo-resistive pressure-sensitive device producing an output voltage proportional to the applied pressure. This low cost, high accuracy device is temperature compensated and shows good linearity and negligible hysteresis. The sensor cell has a good thickness-to-diameter ratio and is sufficiently flexible to conform to most contours of the body. The tubing that conveys the pressure transmitting fluid also serves as a means of keeping the transducer distant from the measuring site. The device showed a highly satisfactory performance under laboratory conditions and has proven to be robust and reliable when used for clinical studies.  相似文献   

15.
This article deals with the euthanasia debate in light of new life‐sustaining technologies such as the left ventricular assist device (LVAD). The question arises: does the switching off of a LVAD by a doctor upon the request of a patient amount to active or passive euthanasia, i.e. to ‘killing’ or to ‘letting die’? The answer hinges on whether the device is to be regarded as a proper part of the patient's body or as something external. We usually regard the switching off of an internal device as killing, whereas the deactivation of an external device is seen as ‘letting die’. The case is notoriously difficult to decide for hybrid devices such as LVADs, which are partly inside and partly outside the patient's body. Additionally, on a methodological level, I will argue that the ‘ontological’ arguments from analogy given for both sides are problematic. Given the impasse facing the ontological arguments, complementary phenomenological arguments deserve closer inspection. In particular, we should consider whether phenomenologically the LVAD is perceived as a body part or as an external device. I will support the thesis that the deactivation of a LVAD is to be regarded as passive euthanasia if the device is not perceived by the patient as a part of the body proper.  相似文献   

16.
We report the first implantation of a percutaneous left ventricular partitioning device in the Netherlands. This device is developed for patients with chronic heart failure due to a left ventricular apical aneurysm caused by an anterior myocardial infarction.  相似文献   

17.
There is a need for a device for improved management of the airway of small laboratory animals during general anaesthesia. This report introduces such a device, referred to here as the airway device (AD). The AD has some similarity to the laryngeal mask airway (LMA) developed for human patients, but the mask portion of the device is specifically designed for small laboratory animals. In addition, the device has an oesophageal extension and unlike the LMA does not have a cuff associated with the mask. This report also shares experience of tests of one prototype AD with six New Zealand white rabbits. The AD was used for administering isoflurane and its effectiveness was evaluated during conditions of spontaneous and controlled intermittent positive pressure ventilation. The results provide encouragement for further development of the AD for airway management of small laboratory animals.  相似文献   

18.
Contact allergy to implantable cardiac defibrillators (ICD) is an uncommon and underdiagnosed complication. We report a case of a 20-years-old man patient that was resuscitated from sudden cardiac death. Workup imaging study was unremarkable, but genetic testing identified a mutation in the KCNH2 gene of uncertain significance. The patient underwent a subcutaneous implantable cardiac defibrillator (S-ICD) implantation, with no complications. The patient suffered two hospital re-admissions due to a device-related inflammatory reaction, leading to two device re-implantations. At the first time, it was considered a bacterial infection and the S-ICD was replaced by an endovascular device. At the second time, a tissue-device interaction, with hypersensitivity reaction and device rejection was suspected. The skin patch-tests were inconclusive, but it was decided to implant a custom-made gold-coated endovascular ICD. Indeed, the tendency is an initial misdiagnosis as an infection and a high clinical suspicion is essential to an early diagnosis.  相似文献   

19.
A bioartificial pancreas is an implantable device which contains insulin secreting cells (Langerhans islets), separated from the circulating blood by a semi-permeable membrane to avoid rejection. This paper describes the operation of such a device and evaluates the respective contributions of diffusion and ultrafiltration to the glucose and insulin mass transfer. It is shown that the pressure drop along the blood channel produces across the first half of the channel an ultrafiltration flux toward the islet compartment followed in the second half by an equal flux in reverse direction from islets to blood. The mass transfer analysis is carried out for an optimal geometry in which a U-shaped blood channel surrounds closely a very thin islet compartment formed by a folded flat membrane. A complete model of insulin release by this device is developed and is compared with in vitro data obtained with rats islets. Satisfactory kinetics is achieved with a polyacrylonitrile membrane used in hemodialysis. But the model shows that the membrane hydraulic permeability should be increased by a factor of 10 to significantly improve the performance.  相似文献   

20.
We propose a novel hybrid single-electron device for reprogrammable low-power logic operations, the magnetic single-electron transistor (MSET). The device consists of an aluminium single-electron transistor with a GaMnAs magnetic back-gate. Changing between different logic gate functions is realized by reorienting the magnetic moments of the magnetic layer, which induces a voltage shift on the Coulomb blockade oscillations of the MSET. We show that we can arbitrarily reprogram the function of the device from an n-type SET for in-plane magnetization of the GaMnAs layer to p-type SET for out-of-plane magnetization orientation. Moreover, we demonstrate a set of reprogrammable Boolean gates and its logical complement at the single device level. Finally, we propose two sets of reconfigurable binary gates using combinations of two MSETs in a pull-down network.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号