首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 593 毫秒
1.
A novel hydrogen peroxide biosensor was fabricated for the determination of H2O2. The precursor film was first electropolymerized on the glassy carbon electrode with p-aminobenzene sulfonic acid (p-ABSA) by cyclic voltammetry (CV). Then thionine (Thi) was adsorbed to the film to form a composite membrane, which yielded an interface containing amine groups to assemble gold nanoparticles (nano-Au) layer for immobilization of horseradish peroxidase (HRP). The electrochemical characteristics of the biosensor were studied by CV and chronoamperometry. The factors influencing the performance of the resulting biosensor were studied in detail. The biosensor responded to H2O2 in the linear range from 2.6 × 10 6 mol/L to 8.8 × 10 3 mol/L with a detection limit of 6.4 × 10 7 mol/L. Moreover, the studied biosensor exhibited good accuracy and high sensitivity. The proposed method was economical and efficient, making it potentially attractive for the application to real sample analysis.  相似文献   

2.
《Process Biochemistry》2007,42(3):363-373
Methane (CH4) and nitrous oxide (N2O) are important greenhouse gases, because of their contribution to the global greenhouse effect. The present study assessed emissions of N2O and CH4 from constructed wetland microcosms, planted with Phragmites australis and Zizania latifolia, when treating wastewater under different biological oxygen demand (BOD) concentration conditions. The removal rate was 95% for BOD and more than 80% for COD in all three pollutant concentrations, both plants’ removal rates of pollutants were at almost the same level, and both were found to resist BOD concentrations as high as 200 mg L−1. When BOD concentrations fell below 200 mg L−1, the soil plant units reached an average of 80–92% T-N and T-P removal rates; however, as the concentrations increased to 200 mg mg L−1 or when during the initial phases of winter, the removal rates for T-N and T-P decreased to less than 70%. With NH3-N removal, the influences of BOD concentrations and air temperature were more obvious. When BOD concentrations increased to 100 mg L−1 after October, an obvious decrease in NH3-N removal was detected; almost no nitrification occurred beginning in December at BOD concentrations of 200 mg mg L−1. N2O and CH4 emissions showed obvious seasonal changes; higher emissions were observed with higher BOD concentrations, especially among Z. latifolia units. The enumeration of methane-oxidizing bacteria and methane-producing bacteria was also conducted to investigate their roles in impacting methane emissions and their relationships with plant species. The pollutant purification potentials of P. australis and Z. latifolia plant units during wastewater treatment of different pollutant concentrations occurred at almost the same levels. The nutrient outflow and methane flux were consistently higher with Z. latifolia units and higher concentrations of BOD. The more reductive status and higher biomass of methanogens may be the reason for the lower nitrification and higher CH4 emissions observed with Z. latifolia units and higher concentration systems. The Z. latifolia root system is shallow, and the activity of methanotrophs is primarily confined to the upper portion of the soil. However, the root system of P. australis is deeper and can oxidize methane to a greater depth. This latter structure is more favorable as it is better for reducing methane emissions from P. australis soil plant systems.  相似文献   

3.
Acetylcholinesterase (AChE) was immobilized on chemically modified poly-(acrylonitrile-methyl-methacrylate-sodium vinylsulfonate) membranes in accordance with three different methods, the first of which involved random enzyme immobilization via glutaraldehyde, the second one—site-specific enzyme immobilization via glutaraldehyde and Concanavalin A (Con A) and the third method—modified site-specific enzyme immobilization via glutaraldehyde in the presence of a mixture of multiwall carbon nanotubes and albumin (MWCNs + BSA), glutaraldehyde and Con A. Preliminary tests for the activity of immobilized AChE were carried out using these three methods. The third method was selected as the most efficient one for the immobilization of AChE and the prepared enzyme carriers were used for the construction of amperometric biosensors for the detection of acetylthiocholine (ATCh).A five level three factorial central composite design was chosen to determine the optimal conditions for the enzyme immobilization with three critical variables: concentration of enzyme, Concanavalin A and MWCNs. The design illustrated that the optimum values of the factors influencing the amperometric current were CE: 70 U mL−1; CCon A: 1.5 mg mL−1 and CMWCN: 11 mg mL−1, with an amperometric current 0.418 μA. The basic amperometric characteristics of the constructed biosensor were investigated. A calibration plot was obtained for a series of ATCh concentrations ranging from 5 to 400 μM. A linear interval was detected along the calibration curve from 5 to 200 μM. The correlation coefficient for this concentration range was 0.995. The biosensor sensitivity was calculated to be 0.065 μA μM−1 cm−2. The detection limit with regard to ATCh was calculated to be 0.34 μM. The potential application of the biosensor for detection and quantification of organophosphate pesticides was investigated as well. It was tested against sample solutions of Paraoxon. The biosensor detection limit was determined to be 1.39 × 10−12 g L−1 of Paraoxon, as well as the interval (10−11 to 10−8 g L−1) within which the biosensor response was linearly dependant on the Paraoxon concentration. Finally the storage stability of the enzyme carrier was traced for a period of 120 days. After 30-day storage the sensor retained 76% of its initial current response, after 60 days—68% and after 120 days—61%.  相似文献   

4.
A horizontal subsurface flow (HSSF) and a free water surface flow (FWSF) constructed wetlands (4 m2 of each) were set up on the campus of Harran University, Sanliurfa, Turkey. The main objective of the research was to compare the performance of two systems to decide the better one for future planning of wastewater treatment system on the campus. Both of the wetland systems were planted with Phragmites australis and Canna indica. During the observation period (10 months), environmental conditions such as pH, temperature and total chemical oxygen demand (COD), soluble COD, total biochemical oxygen demand (BOD), soluble BOD, total suspended solids (TSS), total phosphate (TP), total nitrogen (TN) removal efficiencies of the systems were determined. According to the results, average yearly removal efficiencies for the HSSF and the FWSF, respectively, were as follows: total COD (75.7% and 69.9%), soluble COD (85.4% and 84.3%), total BOD (79.6% and 87.6%), soluble BOD (87.7% and 95.3%), TN (33.2% and 39.4%), and TP (31.5% and 6.5%). Soluble COD and BOD removal efficiencies of both systems increased gradually since the start-up. After nine months of operation, above 90% removal of organic matters were observed. The treatment performances of the HSSF were better than that of the FWSF with regard to the removal of suspended solids and total COD at especially high temperatures. In FWSF systems, COD concentrations extremely exceeded the discharge limit values due to high concentrations of algae in spring months.The performance of the two systems was modelled using an artificial neural network-back-propagation algorithm. The ANN model was competent at providing reasonable match between the measured and the predicted concentrations of total COD (R = 0.90 for HSSF and R = 0.96 for FWSF), soluble COD (R = 0.90 for HSSF and R = 0.74 for FWSF) and total BOD (R = 0.94 for HSSF and R = 0.84 for FWSF) in the effluents of constructed wetlands.  相似文献   

5.
In this study, a novel glucose biosensor was fabricated by reconstitutional immobilization of glucose oxidase (GOx) onto a poly(glycidyl methacrylate-co-vinylferrocene) (poly(GMA-co-VFc)) film coated pencil graphite electrode (PGE). The amperometric current response of poly(GMA-co-VFc)-GOx to glucose is linear in the concentration range between 1 and 16 mM (correlation coefficient of 0.9998) with a detection limit of 2.7 μM (S/N = 3). Experimental parameters were studied in detail and optimized, including the pH and temperature governing the analytical performance of the biosensor. The stability and reusability of the biosensor as well as its kinetic parameters have also been studied.  相似文献   

6.
d-Amino acid oxidase (DAAO) purified from goat kidney was immobilized covalently via N-ethyl-N-(3-dimethylaminopropyl) carbodiimide (EDC) and N-hydroxy succinimide (NHS) chemistry onto poly indole 5-carboxylic acid (Pin5-COOH)/zinc sulfide nanoparticles (ZnSNPs) hybrid film electrodeposited on surface of an Au electrode. A highly sensitive d-amino acid biosensor was constructed using this enzyme electrode as working electrode, Ag/AgCl as reference electrode, and Pt wire as auxiliary electrode connected through potentiostat. The biosensor showed optimum response within 3 s at pH 7.5 and 35 °C, when polarized at 0.15 V vs. Ag/AgCl. There was a linear relationship between biosensor response (mA) and d-alanine concentration in the range 0.001–2.0 mM. The sensitivity of the biosensor was 58.85 μA cm?2 mM?1 with a detection limit of 0.001 mM (S/N = 3). The enzyme electrode was used 120 times over a period of 2 months when stored at 4 °C. The biosensor has an advantage over earlier enzyme sensors that it has no leakage of enzyme during reuse and is unaffected by the external environment due to the protective layer of poly indole-5-carboxylic acid film. The biosensor was evaluated and employed for measurement of d-amino acid level in fruits and vegetables.  相似文献   

7.
The experiment was conducted to develop an integrated treatment system for coffee processing wastewater (CPWW) through the combination of biomethanation with aeration and wetland plants treatment. The biomethanation was carried out at different hydraulic retention times (HRTs) using upflow anaerobic hybrid reactor (UAHR) and 18 h of HRT was found to be optimum. The maximum biochemical oxygen demand (BOD), chemical oxygen demand (COD) and total solids (TS) reduction were 66.0%, 61.0% and 58.0%, respectively with organic loading rate of 9.55 kg m?3 day?1. The reduction of pollution load of the wastewater by microbial action augmented by aeration resulted in the reduction of electrical conductivity (EC), BOD, COD, and total solids (TS). Continuous aeration of wastewater resulted in maximum reduction of BOD (74.6%), COD (68.6%) and TS (49.3%). The wetland plant, Typha latifolia reduced 85.4% and 78.0% of BOD and COD, respectively in biomethanated cum aerated CPWW.  相似文献   

8.
A facile method of preparing water-dispersible sulfonated graphene (SPG) using sulfonated poly(ether–ether–ketone) organic polymer as a modifier was realized. A glucose biosensor was fabricated by immobilizing glucose oxidase (GOx) on the surface of AuNPs used to modify SPG and chitosan (CH) deposited on an indium tin-oxide (ITO) glass electrode by a solution casting method. Morphological and structural characterizations confirm that the AuNPs can be efficiently applied to the SPG–CH matrix. The amperometric response of the GOx/SPG–AuNPs–CH/ITO bioelectrode shows a broad linear range of 0.5 to 22.2 mM, with a limit of detection of 0.13 mM and a high sensitivity of 6.51 μA/(mM cm2). The excellent performance of the constructed biosensor is attributed to the large surface-to-volume ratio and electron transfer ability of SPG, the high catalytic activity of the AuNPs, and the good biocompatibility of CH. In addition, the sensor has important advantages, such as its simple preparation, fast response time (10 s), good stability (70 days), and high reproducibility. Favorable results upon examining the electrochemical response for the determination of glucose in human blood serum were obtained, without the assistance of a negligible effect of interfering bio-analytes. The results of studies show that the ternary SPG–AuNPs–CH nanocomposite may offer a new approach for developing novel types of highly sensitive and stable electrochemical biosensors.  相似文献   

9.
In this work, a biosensor using a glassy carbon electrode modified with gold nanoparticles (AuNPs) and tyrosinase (Tyr) within a dihexadecylphosphate film is proposed. Cystamine and glutaraldehyde crosslinking agents were used as a support for Tyr immobilization. The proposed biosensor was characterized by scanning electron microscopy (SEM), transmission electron microscopy (TEM), and cyclic voltammetry in the presence of catechol. The determination of catechol was carried out by amperometry and presented a linear concentration range from 2.5 × 10−6 to 9.5 × 10−5 mol L−1 with a detection limit of 1.7 × 10−7 mol L−1. The developed biosensor showed good repeatability and stability. Moreover, this novel amperometric method was successfully applied in the determination of catechol in natural water samples. The results were in agreement with a 95% confidence level for those obtained using the official spectrophotometric method.  相似文献   

10.
An amperometric biosensor was developed for determination of urea using electrodeposited rhodium on a polymer membrane and immobilized urease. The urease catalyzes the hydrolysis of urea to NH4+ and HCO3 ions and the liberated ammonia is catalytically and electrochemically oxidized by rhodium present in the rhodinized membrane on the Pt working electrode. Three types of rhodinized polymer membranes were prepared by varying the number of electrodeposition cycles: membrane 1 with 10 deposition cycles, membrane 2 with 40 cycles and membrane 3 with 60 cycles. The morphologies of the rhodinized membranes were investigated by scanning electron microscopy and the results showed that the deposition of rhodium was like flowers with cornices-like centers. The influence of the amount of electrodeposited rhodium over the electrode sensitivity to different concentrations of ammonia was examined initially based on the cyclic voltammetric curves using the three rhodium modified electrodes. The obtained results convincingly show that electrode with rhodinized membrane 1, which contain the lowest amount of electrodeposited rhodium is the most active and sensitive regarding ammonia. It was found that the anodic oxidation peak of ammonia to nitrogen occurs at 0.60 V. In order to study the performance of urease amperometric sensor for the determination of urea, experiments at constant potential (0.60 V) were performed. The current–time experiments were carried out with urease rhodinized membrane 1 (10 cycles). The amperometric response increased linearly up to 1.75 mM urea. The detection limit was 0.05 mM. The urea biosensor exhibited a high sensitivity of 1.85 μA mM−1 cm−2 with a response time 15 s. The Michaelis–Menten constant Km for the urea biosensor was calculated to be 6.5 mM, indicating that the immobilized enzyme featured a high affinity to urea. The urea sensor showed a good reproducibility and stability. Both components rhodium and urease contribute to the decreasing of the production cost of biosensor by avoiding the use of a second enzyme.  相似文献   

11.
In this article we report a selective urea electrochemical biosensor based on electro-co-deposited zirconia-polypropylene imine dendrimer (ZrO2-PPI) nanocomposite modified screen printed carbon electrode (SPCE). ZrO2 nanoparticles, prepared by modified sol–gel method were dispersed in PPI solution, and electro-co-deposited by cyclic voltammetry onto a SPCE surface. The material and the modified electrodes were characterised using FTIR, electron microscopy and electrochemistry. The synergistic effect of the high active surface area of both materials, i.e. PPI and ZrO2 nanoparticles, gave rise to a remarkable improvement in the electrocatalytic properties of the biosensor and aided the immobilisation of the urease enzyme. The biosensor has an ampereometric response time of ∼4 s in urea concentration ranging from 0.01 mM to 2.99 mM with a correlation coefficient of 0.9985 and sensitivity of 3.89 μA mM−1 cm−2. The biosensor was selective in the presence of interferences. Photochemical study of the immobilised enzyme revealed high stability and reactivity.  相似文献   

12.
Adipocyte–macrophage cross-talk propagates immune responses in obese adipose tissue (AT). Long-chain n-3 polyunsaturated fatty acids (LC n-3 PUFA) mitigate inflammation, partly through up-regulation of adiponectin; however, specific mechanisms are unclear. We determined if adipocyte–macrophage cross-talk could be mitigated by dietary LC n-3 PUFA and if this was dependent on adiponectin-mediated signaling. We utilized an in vitro co-culture model mimicking the ratio of adipocytes:macrophages in obese AT, whereby 3T3-L1 adipocytes were co-cultured with splenic CD11b+ macrophages from C57BL/6 mice fed high-fat control (HF-CON; 34% w/w fat) or fish oil diets (HF-FO; 34% w/w fat containing 7.6% w/w FO), as well as mice fed low-fat control (LF-CON; 10% w/w fat) or FO diets (LF-FO; 10% w/w fat containing 3% w/w FO). Co-culture conditions tested effects of soluble mediator-driven mechanisms (trans-well system), cell contact and low-dose lipopolysaccharide (LPS) mimicking acute or chronic inflammatory conditions. HF-FO macrophages from acute LPS-stimulated trans-well co-cultures had decreased mRNA expression of Casp1, Il1β and Il18, as well as cellular caspase-1 activity compared to HF-CON macrophages (P  .05). Moreover, adipocytes from acute LPS-stimulated HF-FO co-cultures had decreased caspase-1 activity and decreased IL-1β/IL-18 levels following chronic LPS pretreatment compared to HF-CON co-cultures (P  .05). Additionally, in contact co-cultures with adiponectin-neutralizing antibody, the FO-mediated modulation of NFκB activity and decrease in phosphorylated p65 NFκB, expression of NLRP3 inflammasome genes, M1 macrophage marker genes and inflammatory cytokine/chemokine secretion were controlled partly through adiponectin, while cellular caspase-1 activity and IL-1β/1L-18 levels were decreased independently of adiponectin (P  .05). LC n-3 PUFA may decrease the intensity of adipocyte–macrophage cross-talk to mitigate obesity-associated pathologies.  相似文献   

13.
Gliomas are the most important group of malignant primary brain tumors and one of the most aggressive forms of cancer. During the last years, several studies have demonstrated that cannabinoids induce apoptosis of glioma cells and inhibit angiogenesis of gliomas in vivo. As the effects of cannabinoids rely on CB1 and CB2 receptors activation, the aim of the present study was to investigate both receptors protein expression in cellular membrane homogenates of human glial tumors using specific antibodies raised against these proteins. Additionally, we studied the functionality of the cannabinoid receptors in glioblastomas by using WIN 55,212-2 stimulated [35S]GTPγS binding.Western blot analysis showed that CB1 receptor immunoreactivity was significantly lower in glioblastoma multiforme (?43%, n = 10; p < 0.05) than in normal post-mortem brain tissue (n = 16). No significant differences were found for astrocytoma (n = 6) and meningioma (n = 8) samples. Conversely, CB2 receptor immunoreactivity was significantly greater in membranes of glioblastoma multiforme (765%, n = 9; p < 0.05) and astrocytoma (471%, n = 4; p < 0.05) than in control brain tissue (n = 10). Finally, the maximal stimulation of [35S]GTPγS binding by WIN 55,212-2 was significantly lower in glioblastomas (134 ± 4%) than in control membranes (183 ± 2%; p < 0.05). The basal [35S]GTPγS binding and the EC50 values were not significantly different between both groups.The present results demonstrate opposite changes in CB1 and CB2 receptor protein expression in human gliomas. These changes may be of interest for further research about the therapeutic effects of cannabinoids in glial tumors.  相似文献   

14.
Biopolymer pectin stabilized gold nanoparticles were prepared at graphene and multiwalled carbon nanotubes (GR-MWNTs/AuNPs) and employed for the determination of glucose. The formation of GR-MWNTs/AuNPs was confirmed by scanning electron microscopy, X-ray diffraction, UV–vis and FTIR spectroscopy methods. Glucose oxidase (GOx) was successfully immobilized on GR-MWNTs/AuNPs film and direct electron transfer of GOx was investigated. GOx exhibits highly enhanced redox peaks with formal potential of −0.40 V (vs. Ag/AgCl). The amount of electroactive GOx and electron transfer rate constant were found to be 10.5 × 10−10 mol cm−2 and 3.36 s−1, respectively, which were significantly larger than the previous reports. The fabricated amperometric glucose biosensor sensitively detects glucose and showed two linear ranges: (1) 10 μM  2 mM with LOD of 4.1 μM, (2) 2 mM  5.2 mM with LOD of 0.95 mM. The comparison of the biosensor performance with reported sensors reveals the significant improvement in overall sensor performance. Moreover, the biosensor exhibited appreciable stability, repeatability, reproducibility and practicality. The other advantages of the fabricated biosensor are simple and green fabrication approach, roughed and stable electrode surface, fast in sensing and highly reproducible.  相似文献   

15.
A glucose biosensor using a glucose oxidase (GOx)-immobilized nylon net with glutaraldehyde as cross-linking reagent and an oxygen (O2) electrode for the determination of glucose has been fabricated. The detection scheme was based on the utilization of dissolved O2 in oxidation of glucose by the membrane bound GOx. Crucial factors including O-alkylation temperature, reaction times of nylon net with dimethyl sulfate, l-lysine, and glutaraldehyde, and enzyme loading were examined to determine the optimal enzyme immobilization conditions for the best sensitivity of the developed glucose biosensor. In addition, the effects of pH and concentration of phosphate buffer on the response of the biosensor were studied. The glucose biosensor had a linear range of 18 μM to 1.10 mM with the detection limit of 9.0 μM (S/N = 3) and response time of 80 s. The biosensor exhibited both good operational stability with over 200 measurements and long-term storage stability. The results from this biosensor compared well with those of a commercial glucose assay kit in analyzing human serum glucose samples.  相似文献   

16.
This study evaluates the potential of subsurface flow (SSF) constructed wetlands (CWs) for tertiary treatment of wastewater at four shorter HRTs (1–4 days). The CWs were planted with Typha angustata, which was observed in our earlier study to be more efficient than Phragmites karka and Scirpus littoralis. The CWs comprised four rectangular treatment cells (2.14 m × 0.76 m × 0.61 m) filled with layers of gravel of two different sizes (approximately 2.5 cm and 1.5 cm diameter) to a depth of 0.61 m. The inflow rates of the secondary effluent in the four cells were accordingly fixed at 300 L d?1, 150 L d?1, 100 L d?1 and 75 L d?1, respectively, for 1, 2, 3 and 4 days HRT. The hydraulic loads ranged between 59.05 mm d?1 and 236.22 mm d?1.The wastewater inflow into the CW system as well as the treated effluent were analyzed, using standard methods, at regular intervals for various forms of nitrogen (NH4-N, NO3-N and TKN), orthophosphate-P and organic matter (BOD and COD) concentrations over a period of five weeks after the development of a dense stand.The higher HRT of 4 days not only helped maximum removal of all the pollutants but also maintained the stability of the treatment efficiency throughout the monitoring period. For the nutrients (NH4-N, NO3-N and TKN), HRT played a more significant role in their removal than in case of organic matter (BOD3 and COD). More than 90% of NO3-N and TKN and 100% of NH4-N were removed from the wastewater at 4 days HRT.At lower HRTs, the mass loading rate was higher with greater fluctuation. However mass reduction efficiency of the T. angustata CW for all forms of nitrogen was >80% with the HRTs of 2, 3 and 4 days.  相似文献   

17.
A method is described for construction of an amperometric xanthine biosensor based on covalent Immobilization of xanthine oxidase (XOD) onto citrate capped silver nanoparticles deposited on Au electrode surface through cysteine self assembled monolayers (SAM). The biosensor showed optimum response within 5 s at pH 7.0 and 35 °C, when polarized at 0.5 V vs. Ag/AgCl. The linear working range of biosensor for xanthine was from 2 to 16 μM, with a detection limit of 0.15 μM and sensitivity of 0.17 mA/μM/cm2. The mean analytical recovery of exogenously added xanthine in fish meat extract (5 g/l and 10 g/l) was 96.2 ± 2.3% and 95.2 ± 3.4%, respectively. Within and between batches coefficients of variation were <2.6% and <3.4%, respectively. The biosensor measured xanthine in fish, chicken, pork, and beef meat. The enzyme electrode lost 20% of its initial activity after its regular 180 uses over a period of 60 days, when stored at 4 °C in dry state.  相似文献   

18.
BackgroundBariatric surgery is widely performed to improve obesity-related disorders, but can lead to nutrient deficiencies. In this study we examined serum trace element concentrations before and after bariatric surgery.MethodsWe obtained serum trace element concentrations by inductively coupled plasma-mass spectrometry (ICP-MS) method in 437 patients (82% women, median preoperative body-mass index 46.7 kg/m2 [interquartile range 42–51]) undergoing either gastric banding (22.7%), sleeve gastrectomy (20.1%), or gastric bypass (57.3%) procedures. Trace element data were available for patients preoperatively (n = 44); and 3 (n = 208), 6 (n = 174), 12 (n = 122), 18 (n = 39), 24 (n = 44) and 36 months (n = 14) post-operatively. All patients were recommended to take a multivitamin-mineral supplement after surgery.ResultsCopper deficiency was found in 2% of patients before surgery; and after surgery deficiency rates ranged from 0 to 5% with no significant change in median concentrations during follow-up (p = 0.68). Selenium deficiency was reported in 2% of patients before surgery; and after surgery deficiency rates ranged from 11 to 15% with a near-significant change in median concentrations (p = 0.056). Zinc deficiency was reported in 7% before surgery; and after surgery deficiency rates ranged from 7 to 15% with no significant change in median concentrations (p = 0.39).ConclusionsIn bariatric surgery patients recommended to take multivitamin-mineral supplements, serum copper, zinc and selenium concentrations were mostly stable during the first years after bariatric surgery. There was a possible tendency for selenium concentrations to decline during the early postoperative period.  相似文献   

19.
BACKGROUNDImportance of androgen receptor (AR) as an independent prognostic marker in Pakistani women with breast cancer (BCa) remains unexplored. Our aim was to identify the expression and potential prognostic value of AR, its upstream regulator (pAkt) and target gene (pPTEN) in invasive BCa.METHODSThis study used a cohort of 200 Pakistani women with invasive BCa diagnosed during 2002-2011. Expression of AR, pAkt and pPTEN was determined on formalin fixed paraffin embedded tissue sections by immunohistochemistry. The association of AR, pAkt and pPTEN with clinicopathological parameters was determined. Survival analyses were undertaken on patients with ≥ 5 years of follow-up (n = 82).RESULTSExpression of AR, pAkt and pPTEN was observed in 47.5%, 81.3% and 50.6% of patients, respectively. AR-expressing tumors were low or intermediate in grade (P < .001) and expressed ER (P = .002) and PR (P = .001). Patients with AR+ tumors had significantly higher OS (Mean OS = 10.2 ± 0.465 years) compared to patients with AR? tumors (Mean OS = 5.8 ± 0.348 years) (P = .047). Furthermore, AR-positivity was associated with improved OS in patients receiving endocrine therapy (P = .020). Patients with AR+ /pAkt+ /pPTEN? tumors, had increased OS (Mean OS = 7.1 ± 0.535 years) compared to patients with AR?/pAkt+/pPTEN? tumors (Mean OS = 5.1 ± 0.738 years).CONCLUSIONAR-expressing tumors are frequently characterized by low or intermediate grade tumors, expressing ER and PR. In addition, expression of AR, pAkt and pPTEN, could be considered in prognostication of patients with invasive BCa.  相似文献   

20.
Poly(acrylonitrile-methylmethacrylate-sodium vinylsulfonate) membranes were chemically modified and loaded with gold nanoparticles. Acetylcholinesterase was immobilized on the prepared membranes in accordance with two distinctive procedures, the first of which involved immobilization of the enzyme by convection, and the other by diffusion. The prepared enzyme carriers were used for the construction of amperometric biosensors for detection of acetylthiocholine.Two sets of experiments were carried out. The first set was designed so that to evaluate the effects of the gold nanoparticle deployment and the immobilization procedures over the biosensor effectiveness. The other set of experiments was conducted in order to determine the influence of the individual components of the enzyme mixture, containing gold nanoparticles, acetylcholinesterase, bovine serum albumin and glutaraldehyde, over the current output of the constructed acetylthiocholine biosensors. The optimum composition of the mixture was determined to be as follows: enzyme, 0.1 U ml?1; gold nanoparticles, 0.50 ml (per 1 ml enzyme mixture); albumin, 0.5% and glutaraldehyde, 0.7%.On the basis of the experimental results, the most efficient enzyme membrane was selected and used for the preparation of an acetylthiocholine biosensor. Its basic amperometric characteristics were investigated. A calibration plot was obtained for ATCh concentration ranging from 10 to 400 μM. A linear interval was detected along the calibration curve from 10 to 170 μM. The sensitivity of the constructed biosensor was calculated to be 0.066 μA μM?1 cm?2. The correlation coefficient for this concentration range was 0.996. The detection limit with regard to ATCh was calculated to be 1.80 μM.The potential application of the biosensor for detection and quantification of organophosphate pesticides was investigated as well. It was tested against sample solutions of Paraoxon. The biosensor detection limit for Paraoxon was determined, 7.39 × 10?11 g l?1, as well as the concentration interval (10?10 to 10?7 g l?1) within which the biosensor response was linearly dependant on Paraoxon concentration.Finally the storage stability of the enzyme carrier was traced for a period of 50 days. After storage for 20 days the sensor retained 75% of its initial current response and after 30 days ?25%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号