首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The use of an amperometric graphite-Teflon composite tyrosinase biosensor for the rapid monitoring of alkaline phosphatase (ALP), with no need of an incubation step and using phenyl phosphate as the substrate, is reported. Phenol generated by the action of ALP is monitored at the tyrosinase composite electrode through the electrochemical reduction of the o-quinone produced to catechol, which produces a cycle between the tyrosinase substrate and the electroactive product, giving rise to the amplification of the biosensor response and to the sensitive detection of ALP. The current was measured at -0.10 V 5 min after the addition of ALP. As a compromise between high ALP activity and high sensitivity for the detection of phenol, a pH of 8.5 was chosen. The substrate concentration was also optimized. A linear calibration plot was obtained for ALP between 2.0 x 10(-13) and 2.5 x 10(-11), with a detection limit of 6.7 x 10(-14) M. Different types of milk were analyzed with good results, using an extremely simple and rapid procedure.  相似文献   

2.
Han E  Shan D  Xue H  Cosnier S 《Biomacromolecules》2007,8(3):971-975
A new type of amperometric phenol biosensor based on chitosan/layered double hydroxides organic-inorganic composite film was described. This hybrid material combined the advantages of organic biopolymer, chitosan, and inorganic layered double hydroxides. Polyphenol oxidase (PPO) immobilized in the material maintained its activity well as the usage of glutaraldehyde was avoided. The composite films have been characterized by Fourier transform infrared. The results indicated that PPO retained the essential feature of its native structure in the composite film. The enzyme electrode provided a linear response to catechol over a concentration range of 3.6 x 10(-9) to 4 x 10(-5) M with a sensitivity of 2750 +/- 52 mA M(-1) cm(-2) and a detection limit of 0.36 nM based on S/N = 3. The apparent Michaelis-Menten constant K(app)(M) for the sensor was found to be 0.13 mM. The activation energy for enzymatic reaction was calculated to be 27.6 kJ mol(-1). Furthermore, the biosensor exhibited excellent long-term stability and satisfactory reproducibility.  相似文献   

3.
A sensitive and selective amperometric glucose biosensor based on platinum microparticles dispersed in nano-fibrous polyaniline (PANI) was investigated. Poly (m-phenylenediamine) (PMPD), which was employed as an anti-interferent barrier and a protective layer to platinum microparticles, was deposited onto platinum-modified PANI in the presence of glucose oxidase. The morphology of PANI, Pt/PANI and PMPD-GOD/Pt/PANI were investigated by scanning electron microscopy. The results show that PANI has a nano-fibrous morphology. The enzyme electrode exhibits excellent response performance to glucose with linear range from 2 x 10(-6) to 12 x 10(-3) M and fast response time within 7s. Due to the selective permeability of PMPD, the enzyme electrode also shows good anti-interference to uric acid and ascorbic acid. The Michaelis-Menten constant km and the maximum current density imax of the enzyme electrode were 9.34 x 10(-3) M and 917.43 microA cm(-2), respectively. Furthermore, this glucose biosensor also has good stability and reproducibility.  相似文献   

4.
A new zinc oxide nanoparticles/chitosan/carboxylated multiwall carbonnanotube/polyaniline (ZnO-NPs/CHIT/c-MWCNT/PANI) composite film has been synthesized on platinum (Pt) electrode using electrochemical techniques. Three enzymes, creatinine amidohydrolase (CA), creatine amidinohydrolase (CI) and sarcosine oxidase (SO) were immobilized on ZnO-NPs/CHIT/c-MWCNT/PANI/Pt electrode to construct the creatinine biosensor. The enzyme electrode was characterized by scanning electron microscopy (SEM), Fourier transform infrared (FTIR) spectroscopy and electrochemical impedance spectroscopy (EIS). The enzyme electrode detects creatinine level as low as 0.5 μM at a signal to noise ratio of 3 within 10s at pH 7.5 and 30°C. The fabricated creatinine biosensor showed linear working range of 10-650 μM creatinine with a sensitivity of 0.030 μA μM(-1)cm(-2). The biosensor shows only 15% loss of its initial response over a period of 120 days when stored at 4°C. The fabricated biosensor was successfully employed for determination of creatinine in human blood serum.  相似文献   

5.
A new type of sol-gel/organic hybrid composite material based on the cross-linking of natural polymer chitosan with (3-aoryloxypropyl) dimethoxymethylsilane was developed for the fabrication of an amperometric H(2)O(2) biosensor. The composite film was used to immobilize horseradish peroxidase (HRP) on a gold disk electrode. The properties of sol-gel/chitosan and sol-gel/chitosan-HRP films have been carefully characterized by atomic force microscopy and Fourier transform infrared. By using fluorescent label, a protein density on sol-gel/chitosan has been calculated to be 3.14 x 10(12) moleculescm(-2). With the aid of catechol mediator, the biosensor had a fast response of less than 2 s with linear range of 5.0 x 10(-9)-1.0 x 10(-7) mol l(-1) and a detection limit of 2 x 10(-9) mol l(-1). Its current response shows a typical Michaelis-Menten mechanism. The apparent Michaelis-Menten constant K(M)(app) is found to be 1.30 micromol l(-1). The activation energy for enzymatic reaction is calculated to be 8.22 kJ mol(-1). The biosensor retained approximately 75% of its original activity after about 60 days of storage in a phosphate buffer at 4 degrees C.  相似文献   

6.
A novel strategy to fabricate an amperometric biosensor for phenol determination based on chitosan/laponite nanocomposite matrix was described. The composite film was used to immobilize PPO on the surface of a glassy carbon electrode. Chitosan was utilized to improve the analytical performance of the pure clay-modified bioelectrode. The biosensor exhibited a series of properties: good affinity to its substrate (the apparent Michaelis-Menten constant for the sensor was found to be 0.16 mM), high sensitivity (674 mA M(-1)cm(-2) for catechol) and remarkable long-term stability in storage (it retains 88% of the original activity after 60 days). In addition, optimization of the biosensor construction as well as effects of experimental variables such as pH, operating potential and temperature on the amperometric response of the sensor were discussed.  相似文献   

7.
A mediator-free phenol biosensor was developed. The low-isoelectric point tyrosinase was adsorbed on the surface of high-isoelectric point ZnO nanoparticles (nano-ZnO) facilitated by the electrostatic interactions and then immobilized on the glassy carbon electrode via the film forming by chitosan. It was found that the nano-ZnO matrix provided an advantageous microenvironment in terms of its favorable isoelectric point for tyrosinase loading and the immobilized tyrosinase retaining its activity to a large extent. Moreover, there is no need to use any other electron mediators. Phenolic compounds were determined by the direct reduction of biocatalytically generated quinone species at -200mV (vs. saturated calomel electrode). The parameters of the fabrication process and the various experimental variables for the enzyme electrode were optimized. The resulting biosensor can reach 95% of steady-state current within 10s, and the sensitivity was as high as 182microAmmol(-1)L. The linear range for phenol determination was from 1.5x10(-7) to 6.5x10(-5)molL(-1) with a detection limit of 5.0x 10(-8)molL(-1) obtained at a signal/noise ratio of 3. In addition, the apparent Michaelis-Menten constant (K(m)(app)) and the stability of the enzyme electrode were estimated. The performance of the developed biosensor was compared with that of biosensors based on other immobilization matrices.  相似文献   

8.
The design of a new tyrosinase biosensor with improved stability and sensitivity is reported. The biosensor design is based on the construction of a graphite-Teflon composite electrode matrix in which the enzyme and colloidal gold nanoparticles are incorporated by simple physical inclusion. Experimental variables such as the colloidal gold loading into the composite matrix, the enzyme loading and the potential applied to the bioelectrode were optimized. The Tyr-Au(coll)-graphite-Teflon biosensor exhibited suitable amperometric responses at -0.10 V for the different phenolic compounds tested (catechol; phenol; 3,4-dimethylphenol; 4-chloro-3-methylphenol; 4-chlorophenol; 4-chloro-2-methylphenol; 3-methylphenol and 4-methylphenol). The limits of detection obtained were 3 nM for catechol, 3.3 microM for 4-chloro-2-methylphenol, and approximately 20 nM for the rest of phenolic compounds. The presence of colloidal gold into the composite matrix gives rise to enhanced kinetics of both the enzyme reaction and the electrochemical reduction of the corresponding o-quinones at the electrode surface, thus allowing the achievement of a high sensitivity. The biosensor exhibited an excellent renewability by simple polishing, with a lifetime of at least 39 days without apparent loss of the immobilized enzyme activity. The usefulness of the biosensor for the analysis of real samples was evaluated by performing the estimation of the content of phenolic compounds in water samples of different characteristics.  相似文献   

9.
Carbon fiber paper (CFP), a material frequently used as the diffusion layer in fuel cells, was found recently to exhibit a potential as an electrode for the development of sensitive, unmediated biosensors. After nitrogen plasma treatment, the CFP exhibited a quasi-reversible behavior to the redox couple (e.g., ferricyanide) with an electron transfer rate constant of 7.2 × 10(-3)cms(-1). This rate constant is approximately double that of a Pt-electrode and is much higher than that of many carbon-based electrodes. The unmediated CFP-based tyrosinase biosensor fabricated for this study exhibited an optimal working potential and operating pH value of -0.2V and 6.5, respectively. Compared to other unmediated tyrosinase biosensors, the CFP-based tyrosinase biosensor offers a high sensitivity for the monitoring of phenolic compounds (17.8, 7.1, 5.2 and 3.7 μA μM(-1)cm(-2) for catechol, phenol, bisphenol and 3-aminophenol, respectively). The lowest detection limit for catechol, phenol, bisphenol and 3-aminophenol was 2, 5, 5 and 12 nM, respectively. Furthermore, this biosensor exhibited a good repeatability, a fast response time (around 10s), and a wide linear dynamic range of detection for phenolic compounds.  相似文献   

10.
An amperometric tyrosinase enzyme electrode for the determination of phenols was developed by a simple and effective immobilization method using sol-gel techniques. A grafting copolymer was introduced into sol-gel solution and the composition of the resultant organic-inorganic composite material was optimized, the tyrosinase retained its activity in the sol-gel thin film and its response to several phenol compounds was determined at 0 mV vs. Ag/AgCl (sat. KCl). The dependences of the current response on pH, oxygen level and temperature were studied, and the stability of the biosensor was also evaluated. The sensitivity of the biosensor for catechol, phenol and p-cresol was 59.6, 23.1 and 39.4 microA/mM, respectively. The enzyme electrode maintained 73% of its original activity after intermittent use for three weeks when storing in a dry state at 4 degrees C.  相似文献   

11.
Xian Y  Hu Y  Liu F  Xian Y  Wang H  Jin L 《Biosensors & bioelectronics》2006,21(10):1996-2000
In this paper, we report a novel glucose biosensor based on composite of Au nanoparticles (NPs)-conductive polyaniline (PANI) nanofibers. Immobilized with glucose oxidase (GOx) and Nafion on the surface of nanocomposite, a sensitive and selective biosensor for glucose was successfully developed by electrochemical oxidation of H2O2. The glucose biosensor shows a linear calibration curve over the range from 1.0x10(-6) to 8.0x10(-4) mol/L, with a slope and detection limit (S/N=3) of 2.3 mA/M and 5.0x10(-7) M, respectively. In addition, the glucose biosensor system indicates excellent reproducibility (less than 5% R.S.D.) and good operational stability (over 2 weeks).  相似文献   

12.
Cross-linked enzyme crystals (CLECs) are a versatile form of biocatalyst that can also be used for biosensor application. Laccase from Trametes versicolor (E.C.1.10.3.2) was crystallized, cross-linked and lyophilized with beta-cyclodextrin. The CLEC laccase was found to be highly active towards phenols like 2-amino phenol, guaiacol, catechol, pyrogallol, catechin and ABTS (non-phenolic). The CLEC laccase was embedded in 30% polyvinylpropylidone (PVP) gel and mounted into an electrode to make the sensor. The biosensor was used to detect the phenols in 50-1000 micromol concentration level. Phenols with lower molecular weight such as 2-amino phenol, catechol and pyrogallol gave a short response time where as the higher molecular weight substrates like catechin and ABTS had comparatively a long response time. The optimum pH of the analyte was 5.5-6.0 when catechol was used as substrate. The CLEC laccase retained good activity for over 3 months.  相似文献   

13.
A novel tyrosinase biosensor based on Fe(3)O(4) nanoparticles-chitosan nanocomposite has been developed for the detection of phenolic compounds. The large surface area of Fe(3)O(4) nanoparticles and the porous morphology of chitosan led to a high loading of enzyme and the entrapped enzyme could retain its bioactivity. The tyrosinase-Fe(3)O(4) nanoparticle-chitosan bionanocomposite film was characterized with atomic force microscopy and AC impedance spectra. The prepared biosensor was used to determine phenolic compounds by amperometric detection of the biocatalytically liberated quinone at -0.2V vs. saturated calomel electrode (SCE). The different parameters, including working potential, pH of supporting electrolyte and temperature that governs the analytical performance of the biosensor have been studied in detail and optimized. The biosensor was applied to detect catechol with a linear range of 8.3 x 10(-8) to 7.0 x 10(-5)mol L(-1), and the detection limit of 2.5 x 10(-8)mol L(-1). The tyrosinase biosensor exhibits good repeatability and stability. Such new tyrosinase biosensor shows great promise for rapid, simple, and cost-effective analysis of phenolic contaminants in environmental samples. The proposed strategy can be extended for the development of other enzyme-based biosensors.  相似文献   

14.
A feasible and sensitive biosensor for catechol and its derivatives using 2,3-dihydroxybiphenyl 1,2-dioxygenase (BphC)-modified glassy carbon electrode was successfully constructed by polyvinyl alcohol-modified SiO? sol-gel method. The as-prepared biosensor was characterized by electrochemical impedance spectroscopy, and the surface topography of the film was imaged by atomic force microscope. Liquid chromatography-tandem mass spectrometry was applied to reveal the catalytic mechanism. BphC embedded in SiO? gel maintained its bioactivity well and exhibited excellent eletrocatalytical response to both catechol and some of its derivatives (such as 3-methylcatechol and 4-methylcatechol). The biosensor showed a linear amperometric response range between 0.002 mM and 0.8 mM catechol. And the sensitivity was 1.268 mA/(mM cm2) with a detection limit of 0.428 μM for catechol (S/N = 3). Furthermore, the BphC biosensor exhibited perfect selectivity for catechol in the mixtures of catechol and phenol. It was suggested that this flexible protocol would open up a new avenue for designing other ring-cleavage enzyme biosensors, which could be widely used for monitoring various kinds of environmental pollutants.  相似文献   

15.
Naturally occurring Cameroonian smectite clay has been grafted with trimethylpropylammonium (TMPA) groups and the resulting organoclay has been deposited onto a glassy carbon electrode surface as a suitable immobilization matrix for polyphenol oxidase (PPO). High sensitivity of the electrochemical device to catechol biosensing can be achieved when the enzyme was impregnated within the organoclay film subsequent to its deposition due to favorable electrostatic interaction between PPO and the TMPA-clay layer. The bioelectrode preparation method was also compatible with the use of a mediator (i.e., ferrocene) and the best performance was obtained with a three-layer configuration made of glassy carbon coated with a first layer of ferrocene (Fc), which was then covered with the PPO-impregnated TMPA-clay layer, and finally overcoated with an enzyme-free TMPA-clay film acting as a protecting overlayer to avoid leaching of the biomolecule in solution. The electrochemical behavior of the modified film electrodes was first characterized by cyclic voltammetry and, then, they were evaluated for the amperometric biosensing of the model analyte catechol in batch conditions and in flow injection analysis. Various experimental parameters likely to influence the biosensor response have been investigated, including the electrode preparation mode (composition configuration, thickness), the usefulness of a mediator, the operating potential and pH of the medium, as well as the advantageous features of the TMPA-clay in comparison to related film electrodes based on non-functionalized clays. The organoclay was found to provide a favorable environment to enzyme activity and the multilayer configuration of the film electrode to provide a biosensor with good characteristics, such as an extended linear range for catechol detection (2 x 10(-8) to 1.2 x 10(-5)M) and a detection limit in the nanomolar range (9 x 10(-9)M).  相似文献   

16.
Tan X  Li M  Cai P  Luo L  Zou X 《Analytical biochemistry》2005,337(1):111-120
A new type of amperometric cholesterol biosensor based on sol-gel chitosan/silica and multiwalled carbon nanotubes (MWCNTs) organic-inorganic hybrid composite material was developed. The hybrid composite film was used to immobilize cholesterol oxidase on the surface of Prussian blue-modified glass carbon electrode. Effects of some experimental variables such as enzyme loading, concentration of Triton X-100, pH, temperature, and applied potential on the current response of the biosensor were investigated. Analytical characteristics and dynamic parameters of the biosensors with and without MWCNTs in the hybrid film were compared, and the results show that analytical performance of the biosensor can be improved greatly after introduction of the MWCNTs. Response time, sensitivity, linear range, limit of detection (S/N=3), and apparent Michaelis-Menten constant Km are 25s, 0.54 microA mM(-1), 8.0 x 10(-6) to 4.5 x 10(-4) M, 4.0 x 10(-6) M, and 0.41 mM for the biosensor without MWCNTs and 13 s, 1.55 microA mM(-1), 4.0 x 10(-6) to 7.0 x 10(-4) M, 1.0 x 10(-6) M, and 0.24 mM for the biosensor with MWCNTs, respectively. The activation energy of the enzyme-catalyzed reaction was measured to be 42.6 kJ mol(-1). This method has been used to determine the free cholesterol concentration in real human blood samples.  相似文献   

17.
A biosensor based on mushroom tissue homogenate for detecting some phenolic compounds (PCs) and usage of the biosensor for quantifying certain substances that inhibit the polyphenol oxidase activity in mushroom (Agaricus bisporus) tissue homogenate is described. The mushroom tissue homogenate was immobilized to the top of a Clark-type oxygen electrode with gelatin and glutaraldehyde. Optimization of the experimental parameters was done by buffer system, pH, buffer concentration, and temperature. Besides, the detection range of eight phenolic compounds were obtained with the help of the calibration graphs. Thermal stability, storage stability, and repeatability of the biosensor were also investigated. A linear response was observed from 20 x 10(-3) to 200 x 10(-3) mM phenol. The biosensor retained approximately 74% of its original activity after 25 days of storage at 4 degrees C. In repeatability studies, variation coefficient (C.V.) and standard deviation (S.D.) were calculated as 2.44% and +/-0.002, respectively. Inhibition studies revealed that the proposed biosensor was applicable for monitoring benzoic acid and thiourea in soft drinks and fruit juices.  相似文献   

18.
A method is described for construction of an amperometric biosensor for detection of phenolic compounds based on covalent immobilization of laccase (Lac) onto manganese dioxide nanoparticles (MnO(2)NPs) decorated carboxylated multiwalled carbon nanotubes (cMWCNTs)/PANI composite electrodeposited onto a gold (Au) electrode through N-ethyl-N'-(3-dimethylaminopropyl) carbodiimide (EDC) and N-hydroxy succinimide (NHS) chemistry. The modified electrode was characterized by scanning electron microscopy (SEM), cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The biosensor showed optimum response at pH 5.5 (0.1M sodium acetate buffer) and 35°C, when operated at 0.3 V vs. Ag/AgCl. Linear range, response time, detection limit were 0.1-10 μM (lower concentration range) and 10-500 μM (higher concentration range), 4s and 0.04 μM, respectively. Biosensor measured total phenolic content in tea leaves extract. The enzyme electrode was used 150 times over a period of 5 months.  相似文献   

19.
A novel hydrogen peroxide biosensor was fabricated for the determination of H(2)O(2). The precursor film was first electropolymerized on the glassy carbon electrode with p-aminobenzene sulfonic acid (p-ABSA) by cyclic voltammetry (CV). Then thionine (Thi) was adsorbed to the film to form a composite membrane, which yielded an interface containing amine groups to assemble gold nanoparticles (nano-Au) layer for immobilization of horseradish peroxidase (HRP). The electrochemical characteristics of the biosensor were studied by CV and chronoamperometry. The factors influencing the performance of the resulting biosensor were studied in detail. The biosensor responded to H(2)O(2) in the linear range from 2.6 x 10(-6) mol/L to 8.8 x 10(-3) mol/L with a detection limit of 6.4 x 10(-7) mol/L. Moreover, the studied biosensor exhibited good accuracy and high sensitivity. The proposed method was economical and efficient, making it potentially attractive for the application to real sample analysis.  相似文献   

20.
A method is described for the construction of an amperometric biosensor for detection of phenolic compounds based on covalent immobilization of laccase onto iron oxide nanoparticles (Fe(3)O(4)NPs) decorated carboxylated multiwalled carbon nanotubes (cMWCNTs)/polyaniline (PANI) composite electrodeposited onto a gold (Au) electrode. The modified electrode was characterized by scanning electron microscopy (SEM), Fourier transform infrared (FTIR) spectroscopy, cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The biosensor showed optimum response within 3s at pH 6.0 (0.1M sodium acetate buffer) and 35°C, when operated at 0.3V vs. Ag/AgCl. Linear range, detection limit were 0.1-10μM (lower concentration range) and 10-500μM (higher concentration range), and 0.03μM respectively. The sensor measured total phenolic content in tea leaves extract. The enzyme electrode lost 25% of its initial activity after its 150 uses over a period of 4 months, when stored at 4°C.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号