首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
3.
Soft tissues, such as tendons, skin, arteries, or lung, are constantly subject to mechanical stresses in vivo. None more so than the aortic heart valve that experiences an array of forces including shear stress, cyclic pressure, strain, and flexion. Anisotropic biaxial cyclic stretch maintains valve homeostasis; however, abnormal forces are implicated in disease progression. The response of the valve endothelium to deviations from physiological levels has not been fully characterized. Here, we show the design and validation of a novel stretch apparatus capable of applying biaxial stretch to viable heart valve tissue, while simultaneously allowing for live en face endothelial cell imaging via confocal laser scanning microscopy (CLSM). Real-time imaging of tissue is possible while undergoing highly characterized mechanical conditions and maintaining the native extracellular matrix. Thus, it provides significant advantages over traditional cell culture or in vivo animal models. Planar biaxial tissue stretching with simultaneous live cell imaging could prove useful in studying the mechanobiology of any soft tissue.  相似文献   

4.
Leaflet thrombosis following transcatheter aortic valve replacement (TAVR) and Valve-in-Valve (ViV) procedures has been increasingly recognized. This study aimed to investigate the effect of positioning of the transcatheter aortic valve (TAV) in ViV setting on the flow dynamics aspect of post-ViV thrombosis by quantifying the blood stasis in the intra-annular and supra-annular settings. To that end, two idealized computational models, representing ViV intra-annular and supra-annular positioning of a TAV were developed in a patient-specific geometry. Three-dimensional flow fields were then obtained via fluid-solid interaction modeling to study the difference in blood residence time (BRT) on the TAV leaflets in the two settings. At the end of diastole, a strip of high BRT (1.2s) region was observed on the TAV leaflets in the ViV intra-annular positioning at the fixed boundary where the leaflets are attached to the frame. Such a high BRT region was absent on the TAV leaflets in the supra-annular positioning. The maximum value of BRT on the surface of non-, right, and left coronary leaflets of the TAV in the supra-annular positioning were 53%, 11%, and 27% smaller compared to the intra-annular positioning, respectively. It was concluded that the geometric confinement of TAV by the leaflets of the failed bioprosthetic valve in ViV intra-annular positioning increases the BRT on the leaflets and may act as a permissive factor in valvular thrombosis. The absence of such a geometric confinement in the ViV supra-annular positioning leads to smaller BRT and subsequently less likelihood of leaflet thrombosis.  相似文献   

5.
6.
The effect of collagen fibers on the mechanics and hemodynamics of a trileaflet aortic valve contained in a rigid aortic root is investigated in a numerical analysis of the systolic phase. Collagen fibers are known to reduce stresses in the leaflets during diastole, but their role during systole has not been investigated in detail yet. It is demonstrated that also during systole these fibers substantially reduce stresses in the leaflets and provide smoother opening and closing. Compared to isotropic leaflets, collagen reinforcement reduces the fluttering motion of the leaflets. Due to the exponential stress-strain behavior of collagen, the fibers have little influence on the initial phase of the valve opening, which occurs at low strains, and therefore have little impact on the transvalvular pressure drop.  相似文献   

7.
The aortic valve (AV) achieves unidirectional blood flow between the left ventricle and the aorta. Although hemodynamic stresses have been shown to regulate valvular biology, the native wall shear stress (WSS) experienced by AV leaflets remains largely unknown. The objective of this study was to quantify computationally the macro-scale leaflet WSS environment using fluid–structure interaction modeling. An arbitrary Lagrangian–Eulerian approach was implemented to predict valvular flow and leaflet dynamics in a three-dimensional AV geometry subjected to physiologic transvalvular pressure. Local WSS characteristics were quantified in terms of temporal shear magnitude (TSM), oscillatory shear index (OSI) and temporal shear gradient (TSG). The dominant radial WSS predicted on the leaflets exhibited high amplitude and unidirectionality on the ventricularis (TSM>7.50 dyn/cm2, OSI < 0.17, TSG>325.54 dyn/cm2 s) but low amplitude and bidirectionality on the fibrosa (TSM < 2.73 dyn/cm2, OSI>0.38, TSG < 191.17 dyn/cm2 s). The radial WSS component computed in the leaflet base, belly and tip demonstrated strong regional variability (ventricularis TSM: 7.50–22.32 dyn/cm2, fibrosa TSM: 1.26–2.73 dyn/cm2). While the circumferential WSS exhibited similar spatially dependent magnitude (ventricularis TSM: 1.41–3.40 dyn/cm2, fibrosa TSM: 0.42–0.76 dyn/cm2) and side-specific amplitude (ventricularis TSG: 101.73–184.43 dyn/cm2 s, fibrosa TSG: 41.92–54.10 dyn/cm2 s), its temporal variations were consistently bidirectional (OSI>0.25). This study provides new insights into the role played by leaflet–blood flow interactions in valvular function and critical hemodynamic stress data for the assessment of the hemodynamic theory of AV disease.  相似文献   

8.
Mathematical models can provide valuable information to assess and evaluate the mechanical behavior of tissue-engineered constructs. In this study, a structurally based model is applied to describe and analyze the mechanics of tissue-engineered human heart valve leaflets. The results from two orthogonal uniaxial tensile tests are used to determine the model parameters of the constructs after two, three and four weeks of culturing. Subsequently, finite element analyses are performed to simulate the mechanical response of the engineered leaflets to a pressure load. The stresses in the leaflets induced by the pressure load increase monotonically with culture time due to a decrease in the construct's thickness. The strains, on the other hand, eventually decrease as a result of an increase in the elastic modulus. Compared to native porcine leaflets, the mechanical response of the engineered tissues after four weeks of culturing is more linear, stiffer and less anisotropic.  相似文献   

9.
10.
TAVI devices are manufactured with cylindrical frames. However, the frames are rarely cylindrical post-deployment since deformation due to localised under expansion can be induced by calcified material on the native valve leaflets exerting irregular forces upon the frame. Consequently, the leaflets within a deformed TAVI device may undergo elevated stress during operation, which may lead to premature device failure.Using computational analysis a complete TAVI device model was simulated undergoing deployment into an aortic root model derived from CT data for a patient with severe calcific aortic stenosis, followed by a pressure simulated cardiac cycle. The complete analysis was performed eight times, each with the device at a different rotational orientation relative to the native valve, with an increment spacing of 15°.The TAVI device frames consistently featured significant distortions associated with bulky calcified material at the base of the non-coronary sinus. It was found that the average von Mises stress in the prosthetic valves was only increased in one of the cases relative to an idealised device. However, the maximum von Mises stress in the prosthetic valves was elevated in the majority of the cases.Furthermore, it was found that there were preferable orientations to deploy the prosthetic device, in this case, when the prosthetic leaflets were aligned with the native leaflets. As device orientation deviated from this orientation, the stresses in the valve increased because the distance between the prosthetic commissures decreased. This potentially could represent a sufficient increase in stress to induce variation in device lifespan.  相似文献   

11.
12.
Calcification of matrix vesicles in human aortic valve and aortic media.   总被引:18,自引:0,他引:18  
Calcification of human aortic valve and aortic media occurs regularly, increases with age, and is distinctively associated with a zone of lipid accumulation. Ultrastructurally, the accumulated lipids are seen as cellular degradation products derived from senescent and degenerate fibrocytes and smooth muscle cells. The products when deposited in the matrix are morphologically similar to the matrix vesicles described in other calcifying tissues, and serve as the initial site of calcification rather than collagen or elastic fibers. Scattered among the smaller and more typical matrix vesicles, there are seen frequently giant vesicle-like structures measuring several microns in diameter. Many of these large calcified bodies contain needle-shaped, radially arranged apatite crystal deposits. Some of the large calcifying bodies are bounded by folded structures suggesting a membrane component, at times obscured by a more dense floccular osmiophilic deposition. Alcianophilic apparent proteoglycan particles are also adherent to these large calcified bodies. The substance forming the large calcified bodies might be a complex of phospholipids derived from cell membrane and proteoglycan derived from ground substance, this combination possible serving as a nidus for calcification.  相似文献   

13.
The place of balloon dilatation of the aortic valve in the treatment of calcific aortic stenosis is controversial. Thirty two patients (mean age 76) in whom valve replacement was contraindicated were followed up for three to 24 months (mean 8); 25 were in functional class III or IV according to the New York Heart Association''s classification. Major complications of the procedure occurred in four patients. Echocardiography and Doppler studies were performed before operation and before discharge in 28 patients, and the area of the valve was measured again six to 50 (mean 23) weeks after operation in 11 patients. The peak to peak aortic pressure gradient fell from a mean of 65 (SD 24) to 46 (20) mm Hg, but the area of the aortic valve, measured by Doppler echocardiography, in 18 patients showed a modest but significant increase, from 0.61 (0.16) to 0.74 (0.23) cm2. One month after dilatation, 29 patients were alive, of whom 17 had improved symptoms. Only two had lasting clinical benefit. Sixteen patients died, 12 of a cardiac cause. The estimated one year survival rate was 49%. Six patients underwent or required valve replacement because of persisting symptoms. In view of its limited long term efficacy balloon dilatation of the aortic valve should be used only for patients with severe symptoms whose life expectancy is limited by other disease or who are considered to be unsuitable for valve replacement. It may have a role in improving the condition of patients who present with cardiogenic shock or pulmonary oedema before valve replacement is undertaken.  相似文献   

14.
Injections of human chorionic gonadotropin (HCG) have been claimed to aid in weight reduction by reducing hunger, and affecting mood as well as aiding in localized (spot) reduction. We have tested these claims in a double-blind randomized trial using injections of HCG or placebo. Weight loss was identical between the two groups, and there was no evidence for differential effects on hunger, mood or localized body measurements. Placebo injections, therefore, appear to be as effective as HCG in the treatment of obesity.  相似文献   

15.
16.
Motion and position of both mitral leaflets were studied in five normal dogs 1-11 wk after radiopaque markers were sutured on the valve cusps and on the mitral annulus. Cinefluorograms and cineangiograms (100-120 frames/s) of left atrium and left ventricle were used to study cusp motion and intraventricular flow patterns, and to detect mitral regurgitation during sinus rhythm (42-184 beats/min) and during isolated atrial or ventricular contractions. Time-motion of both leaflets was similar throughout diastole with the exception of delayed posterior cusp opening. Peak opening and closing speeds, opening and closing times, and time of complete closure, measured from the Q wave of the ECG, were not significantly affected by the variations in heart rate. Diastolic leaflet closure began immediately after opening, while the ventricular cavity was small, and was caused by flow eddies behind the cusps. Isolated ventricular contractions closed the valve leaflets completely and symmetric valve closure was ensured by the different rates of leaflet edge approximation. In contrast, atrial closure was slow, partial, and of very short duration.  相似文献   

17.
Flexibility of the materials used in the construction of bioprosthetic heart valves is essential for proper valve operation. We therefore examined the bending behaviour of glutaraldehyde treated porcine aortic valve cusps in comparison with fresh aortic valve tissue. We repeatedly bent a total of 35 strips of fresh and treated tissue to curvatures ranging from 0.2 to 2.2 mm-1. We compared the stiffness of the two materials between circumferential and radial bending, natural and reverse curvatures and constant or variable tensile stress (0.8-40 kPa). Our results showed a weak positive relationship between bending stiffness and applied tensile stress and a strong positive dependance of stiffness on tissue thickness (t). For the fresh tissue, the bending stiffness increased in proportion to t1.14 while for the glutaraldehyde treated tissue it increased with t2.18. Fourteen strips of fresh and treated tissue were also histologically processed, sectioned and examined with polarized light microscopy. Collagen fiber wavelengths and shear deformations were measured utilizing the tissue banding patterns produced by polarized light microscopy. The neutral axis of bending was found to lie very close to the outer surface of the tissue, suggesting that aortic leaflets have a very low compressive elastic modulus. The shear strains measured in fresh tissue were 10 +/- 2.7% vs 3 +/- 4.4% for the treated, indicating a stiffening of the tissue following glutaraldehyde fixation. We conclude that both natural and bioprosthetic valve cusps have a complex flexural behaviour that cannot be modeled using simple bending principles, although the bioprosthetic material more closely approximates the simple beam than does the fresh. The non-linear elastic modulus, high compressibility and shearing between fiber layers are likely responsible for the observed behaviour of the fresh tissue, while the cross-linking and dehydrating effects of glutaraldehyde are believed to be responsible for the alteration in bending properties observed in the treated tissue. Our study suggests that bioprosthetic valve material does not adequately mimic the mechanics of the natural valve tissue, and that the current glutaraldehyde fixation process eliminates many of the beneficial, stress-reducing properties of the aortic leaflet.  相似文献   

18.
19.
20.
Netherlands Heart Journal - We sought to investigate real-world outcomes of patients with degenerated biological aortic valve prostheses who had undergone valve-in-valve transcatheter aortic valve...  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号