首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A rapid and reproducible method for the pH measurement in the effluent from density gradient electrofocusing is described. By this procedure, after preparative isoelectric focusing, the detection of protein zones and pH measurement can be accomplished simultaneously, by serially coupling a uv flow cell with a pH flow cell. This last one is connected to the recorder by a control unit, which allows the simultaneous printing of pH and uv absorption on the same chart.  相似文献   

2.
We report here a novel detection scheme for simultaneous detection of NADH and H(2)O(2) based on a bifunctional poly(thionine)-modified electrode. Electropolymerization of thionine on a "preanodized" screen-printed carbon electrode effectively lowers the oxidation potential of NADH to 0.15 V (vs. Ag/AgCl). Since poly(thionine) is also a well known electrochemical mediator for H(2)O(2) reduction, we further developed a poly(thionine)-modified ring disk electrode for simultaneous measurement of nicotinamide adenine dinucleotide (NADH) and hydrogen peroxide (H(2)O(2)) by flow injection analysis. By applying the optimized detection potentials of 0.2V and -0.2V at disk and ring electrodes, respectively, this system allows the simultaneous measurement of both analytes with good sensitivity (0.13 μA/mM for H(2)O(2) and 0.34 μA/mM for NADH) and limit of detection (1.74 μM and 26.0 μM for NADH and H(2)O(2)). This opens the possibility of a whole series of biosensor applications.  相似文献   

3.

Background  

Microarray technology allows simultaneous measurement of thousands of genes in a single experiment. This is a potentially useful tool for evaluating co-expression of genes and extraction of useful functional and chromosomal structural information about genes.  相似文献   

4.
The plant cell pressure probe   总被引:4,自引:0,他引:4  
The pressure probe is a micro manometer for the simultaneous direct recording and manipulation of plant cell hydrostatic pressure. It is used to map in space and time the turgor pressures of individual cells within tissues and organs of intact plants. This is used to study the hydraulic architecture of tissues, tissue movement and the responses of tissues to water stress. The approach can be augmented by simultaneous measurement of individual cell osmotic pressure. This permits the hydraulic driving forces across selectively permeable membranes and walls to be assessed fully. By manipulating manually the pressure, cell wall elasticity and its properties can also be mapped. Under some conditions this can be extended to plastic behaviour.  相似文献   

5.
The simultaneous measurement of homovanillic acid, 3,4-dihydroxyphenylacetic acid, serotonin and 5-hydroxyindoleacetic acid in human plasma by an ultrafiltration and microbore high-performance liquid chromatography—electrochemical detection technique is established. Conventional preparation of blood is very tedious and time-consuming, but isocratic separation of the analytes in plasma ultrafiltrates using a microbore column could be achieved within 10 min. Hence, theoretically, over 140 analyses can be performed in a working day. The detection limit (signal-to-noise ratio = 3) of this method is about 0.1–0.5 pg per injection for all analytes. The required volume of plasma samples can be less than 100 μl. Hence, blood loss is minimal, especially in repeated blood sampling. This rapid, simple and sensitive method can, therefore, be used as a routine clinical tool in the simultaneous measurement of plasma homovanillic acid, 3,4-dihydroxyphenylacetic acid, serotonin and 5-hydroxyindoleacetic acid.  相似文献   

6.
This study involved the development and testing of a system for the simultaneous in vitro measurement of tibiofemoral kinematics and patellofemoral kinematics and forces. Knee motion was tracked using a Vicon 370, and patellofemoral force was measured using a six degree-of-freedom transducer based on the design of Singerman et al. Using this system, twelve knee specimens were tested in supine leg extension under a simulated quadriceps force. The comprehensive set of results corresponds well to the individual results of previous studies. The measurement system will be of value in assessing the effects of total knee arthroplasty on patellar function.  相似文献   

7.
A new type of liquid chromatographic (LC) dual thin-layer amperometric detector for the simultaneous measurement of trace levels of dopamine and serotonin in microdialysates is described. The concentrations of these analytes in rat dialysates are usually in the sub-nanomolar concentration range (typically, 0.10–5.00 pg in 5-μl dialysates). With this dual electrode, a glass-lined microbore column provides excellent sensitivity, selectivity, and separation. In addition, a three- to five-fold improvement in anodic current or cathodic responses over conventional dual electrodes in microbore LC can be achieved. Due to the irreversible electrochemical properties of some interference peaks, this dual electrode provides reliable measurement of dopamine based on the cathodic signal. The detection limit (signal-to-noise RATIO=3) of this assay is 0.02 pg per injection for dopamine or serotonin. This new dual electrode allows the simultaneous measurements of basal dopamine and serotonin in rat striatum dialysates without the use of re-uptake inhibitors in perfusion medium.  相似文献   

8.

Background  

Data integration is currently one of the main challenges in the biomedical sciences. Often different pieces of information are gathered on the same set of entities (e.g., tissues, culture samples, biomolecules) with the different pieces stemming, for example, from different measurement techniques. This implies that more and more data appear that consist of two or more data arrays that have a shared mode. An integrative analysis of such coupled data should be based on a simultaneous analysis of all data arrays. In this respect, the family of simultaneous component methods (e.g., SUM-PCA, unrestricted PCovR, MFA, STATIS, and SCA-P) is a natural choice. Yet, different simultaneous component methods may lead to quite different results.  相似文献   

9.
Summary A rapid procedure is proposed for simultaneous measurement of total and radioactive carbon in soils, soil extracts and plant materials. The procedure involves dry or wet combustion of the sample, total carbon determination with an automatic analyser and C14O2 absorbtion in a liquid for scintillation measurement. The use of methyl-cellosolve plus mono-ethanolamine as a CO2 absorber allows measurements of weakly labelled materials. This method is suitable for fast routine analysis. re]19750929  相似文献   

10.
The initial stability of cementless femoral components is crucial for the long-term success of total hip arthroplasty. This has been reported in animal and clinical studies. Until now, the stability was evaluated by the measurement of relative micromotion on a few simultaneous locations around the stem in cadaveric experiments. This paper presents an extended experimental setup to measure simultaneously local micromotion, subsidence and gap on hundreds of points at the bone-stem interface. This technique we applied to anatomical and straight stems in three pairs of cadaveric femurs. Measurements were in agreement with typically reported values. Conversely to other methods, which measure micromotion between implant and bone anchoring points of the measuring device, our method provides local micromotion between stem surface and adjacent bone surface. The observed variation of micromotion at the peri-implant surface confirms the importance of this simultaneous measure on a lot of points around the implant.  相似文献   

11.
Understanding of adaptive behavior requires the precisely controlled presentation of multisensory stimuli combined with simultaneous measurement of multiple behavioral modalities. Hence, we developed a virtual reality apparatus that allows for simultaneous measurement of reward checking, a commonly used measure in associative learning paradigms, and navigational behavior, along with precisely controlled presentation of visual, auditory and reward stimuli. Rats performed a virtual spatial navigation task analogous to the Morris maze where only distal visual or auditory cues provided spatial information. Spatial navigation and reward checking maps showed experience-dependent learning and were in register for distal visual cues. However, they showed a dissociation, whereby distal auditory cues failed to support spatial navigation but did support spatially localized reward checking. These findings indicate that rats can navigate in virtual space with only distal visual cues, without significant vestibular or other sensory inputs. Furthermore, they reveal the simultaneous dissociation between two reward-driven behaviors.  相似文献   

12.
Circular dichroism (CD) is an important spectroscopic technique for monitoring chirality and biological macromolecule conformation. However, during a CD measurement, absorbance, light scattering/turbidity, and fluorescence can also be detected. The simultaneous measurement of these different spectral features for a single sample is the basis of a multi-mode optical spectrometer. This allows time-efficient gathering of complementary information and provides a scheme to ensure that CD measurements are reliable. Aspects of circular polarization differential light scattering, pH, and temperature variation of a protein (antibody) solution are described. A procedure to help ensure that CD measurements are reliable is described.  相似文献   

13.
Van Winkle LJ 《Amino acids》2001,20(2):105-111
Summary. The stoichiometry of amino acid transport with co- or counter-substrates of a given system has been found to vary with the amino acid species. This phenomenon has been studied directly in only a few cases, however, by measuring the fluxes of the substrates simultaneously. More frequently, the apparent transport stoichiometries of single amino acid species with co- or counter-substrates are estimated indirectly by thermodynamic criteria or cooperative kinetic effects. Unfortunately the latter indirect mea-sures of apparent stoichiometry often yield different results than direct measurement of simultaneous fluxes. These differences often cannot be explained by uncoupled transport of one of the co- or counter-substrates or by other characteristics of the transport process that would make the direct measurement of stoichiometry inaccurate. For these reasons, investigators are encouraged to measure the stoichiometry of transport directly by measuring simultaneous fluxes of co- and counter-substrates. Indirect measures of apparent stoichiometry may, however, reflect important details of a transport mechanism even if they are inconsistent with the actual stoichiometry of transport. Received February 20, 2000 Accepted May 18, 2000  相似文献   

14.
The construction of a modified oxygen electrode based on the commercial Yellow Springs Instrument Clarke-type electrode is described. This electrode can be used in conventional 1 × 1 cm spectrophotometer cell for simultaneous measurement of oxygen consumption and a spectrophotometrically assayable parameter. Agitation of the reaction system is achieved by use of a Conrad magnetic stirrer driven by a magnetic couple to a small electric motor that carries a miniature bar magnet.  相似文献   

15.
Both ceramide and phospholipase D (PLD) have important roles in a variety of signal transduction pathways. Recent evidence suggests that ceramide is a novel second messenger with specific biological effects. Publications in this field have increased rapidly in the last few years. However, a method to directly and rapidly measure cermide production has been lacking. Herein, we report on a novel, inexpensive, direct and rapid assay for the measurement of ceramide and the simultaneous measurement of PLD activity. This method uses labeling of cells with [(14)C]myristic acid and a TLC solvent of ethyl acetate/acetic acid/trimethylpentane. This method avoids the loss of radioactivity and variability due to changes in DAG kinase activity that are associated with the commonly-used DAG kinase assay.  相似文献   

16.
The objective of this study was to assess the precision and accuracy of a nonproprietary, optical three-dimensional (3D) motion analysis system for the simultaneous measurement of soft tissue strains and joint kinematics. The system consisted of two high-resolution digital cameras and software for calculating the 3D coordinates of contrast markers. System precision was assessed by examining the variation in the coordinates of static markers over time. Three-dimensional strain measurement accuracy was assessed by moving contrast markers fixed distances in the field of view and calculating the error in predicted strain. Three-dimensional accuracy for kinematic measurements was assessed by simulating the measurements that are required for recording knee kinematics. The field of view (190 mm) was chosen to allow simultaneous recording of markers for soft tissue strain measurement and knee joint kinematics. Average system precision was between +/-0.004 mm and +/-0.035 mm, depending on marker size and camera angle. Absolute error in strain measurement varied from a minimum of +/-0.025% to a maximum of +/-0.142%, depending on the angle between cameras and the direction of strain with respect to the camera axes. Kinematic accuracy for translations was between +/-0.008 mm and +/-0.034 mm, while rotational accuracy was +/-0.082 deg to +/-0.160 deg. These results demonstrate that simultaneous optical measurement of 3D soft tissue strain and 3D joint kinematics can be performed while achieving excellent accuracy for both sets of measurements.  相似文献   

17.
A cuvette is described for simultaneous measurement of ethylene production and CO2 fixation by intact shoots under controlled environmental conditions. This design overcomes potential problems associated with closed systems conventionally used for studies on ethylene production, allowing accurate determination of rates of ethylene production in plants exposed to different environmental conditions.  相似文献   

18.
A reliable method which permits the simultaneous measurement of pregnenolone, progesterone, 17-OH-progesterone, androstenedione, testosterone, dihydrotestosterone, estrone and estradiol in rat testis is described. After extraction of testicular homogenate with methanol, the method includes separation on a LH-20 column and steroid measurement by specific radioimmunoassays.  相似文献   

19.
This work presents a kinetic study on irreversible inhibition of trypsin by TLCK, using a new experimental approach. The method consists of the incubation of the enzyme with an irreversible inhibitor in the presence of a substrate which allows enzyme turnover as well as continuous measurement of the appearance of the product, a simultaneous change in the initial concentrations of the irreversible inhibitor and enzyme being undertaken, though a constant ratio between the latter, is maintained. This new approach enables the kinetic constants for TLCK, k2 and K1, to be determined.  相似文献   

20.
Potassium flux ratio in voltage-clamped squid giant axons   总被引:14,自引:10,他引:4       下载免费PDF全文
The potassium flux ratio across the axolemma of internally perfused, voltage-clamped giant axons of Loligo pealei has been evaluated at various membrane potentials and internal potassium concentrations ([K]i). Four different methods were used: (a) independent measurement of one-way influx and efflux of 42K; (b) simultaneous measurement of net K current (IK) and 42K influx; (c) simultaneous measurement of IK and 42K efflux; and (d) measurement of potassium conductance and 42K influx at the potassium equilibrium potential. The reliability of each of these methods is discussed. The average value of the exponent n' in the Hodgkin-Keynes equation ranged from 1.5 at -4mV and 200 mM [K]i to 3.3 at -38 mV and 350 mM [K]i and appeared to be a function of membrane potential and possibly of [K]i. It is concluded that the potassium channel of squid giant axon is a multi-ion, single-file pore with three or more sites.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号