首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.

Purpose

To evaluate the scan-rescan reproducibility of high-resolution magnetic resonance imaging (MRI) of middle cerebral artery (MCA) plaque, and calculate the number of subjects needed for future longitudinal clinical studies.

Material and Methods

Twenty two patients with MCA plaque were scanned twice by a T2-weighted fast-spin-echo sequence at 3T. Areas and volumes of MCA lumen, total vessel and plaque were quantified and compared between two repeated scans. Agreement and measurement error was quantified by intraclass correlation coefficient (ICC) and coefficient of variance (CV) as defined by standard deviation (SD) of pair wise difference / mean. Sample size needed to detect 5% to 20% changes in area/volume was calculated using 80% power and 5% significance level.

Results

There was no significant different between the area and volume measurements of two repeated scans (p>0.05) with good agreement (ICC range 0.97–0.98 for area and 0.99 for volume). Relatively small measurement errors were observed with CVs range 6.1%-11.8% for area quantification and 4.9%-8.0% for volume quantification. Volume measurements tended to have 19.7% to 32.2% smaller CVs compared with area measurements. Sample size calculation showed a group of 47 patients was sufficient to detect 5% to 10% changes in MCA area/volume.

Conclusion

High resolution MRI is feasible for quantifying intracranial plaque area and volume in longitudinal clinical studies with low scan-rescan variability. Volume measurement tends to be more reproducible compared with area measurements.  相似文献   

2.

Background

Non-ionizing radiation imaging assessment has been advocated for the patients with adolescent idiopathic scoliosis (AIS). As one of the radiation-free methods, ultrasound imaging has gained growing attention in scoliosis assessment over the past decade. The center of laminae (COL) method has been proposed to measure the spinal curvature in the coronal plane of ultrasound image. However, the reliability and validity of this ultrasound method have not been validated in the clinical setting.

Objectives

To evaluate the reliability and validity of clinical ultrasound imaging on lateral curvature measurements of AIS with their corresponding magnetic resonance imaging (MRI) measurements.

Methods

Thirty curves (ranged 10.2°–68.2°) from sixteen patients with AIS were eligible for this study. The ultrasound scan was performed using a 3-D ultrasound unit within the same morning of MRI examination. Two researchers were involved in data collection of these two examinations. The COL method was used to measure the coronal curvature in ultrasound image, compared with the Cobb method in MRI. The intra- and inter-rater reliability of the COL method was evaluated by intra-class correlation coefficient (ICC). The validity of this method was analyzed by paired Student’s t-test, Bland–Altman statistics and Pearson correlation coefficient. The level of significance was set as 0.05.

Results

The COL method showed high intra- and inter-rater reliabilities (both with ICC (2, K) >0.9, p<0.05) to measure the coronal curvature. Compared with Cobb method, COL method showed no significant difference (p<0.05) when measuring coronal curvature. Furthermore, Bland-Altman method demonstrated an agreement between these two methods, and Pearson’s correlation coefficient (r) was high (r>0.9, p<0.05).

Conclusion

The ultrasound imaging could provide a reliable and valid measurement of spinal curvature in the coronal plane using the COL method. Further research is needed to validate the proposed ultrasound measurement in larger clinical trial and to optimize the ultrasound scanning and measuring procedure.  相似文献   

3.

Introduction

There is limited evidence regarding intra-observer and inter-observer variations in echocardiographic measurements of diastolic function. This study aimed to assess this reproducibly within a population-based cohort study.

Methods

Sixty subjects in sinus rhythm were randomly selected among 4th visit participants of the STANISLAS Cohort (Lorraine region, France). This 4th examination systematically included M-mode, 2-dimensional, DTI and pulsed-wave Doppler echocardiograms. Reproducibility of variables was studied by intra-class correlation coefficients (ICC) and Bland Altman plots.

Results

Our population was on average middle-aged (50 ± 14y), overweight (BMI = 26 ± 6kg/m2) and non-smoking (87%) with a quarter of the participants having self-declared hypertension or treated with anti-hypertensive medication(s). Intra-observer ICC were > 0.90 for all analyzed parameters except for left ventricular ejection fraction (LVEF) which was 0.89 (0.81–0.93). The mean relative intra-observer differences were small and limits of agreement of relative differences were narrow for all considered parameters (<5% and <15% respectively). Inter-observer ICC were > 0.90 for all analyzed parameters except for LVEF (ICC = 0.87) and both mitral and pulmonary A wave duration (0.83 and 0.73 respectively). The mean relative inter-observer differences were <5% for all parameters except for pulmonary A wave duration (mean difference = 6.5%). Limits of agreement of relative differences were narrow (<15%), except for mitral A wave duration and velocity (both <20%) as well as left ventricular mass and pulmonary A wave duration (both <30%). Intra-observer agreements with regard to the presence and severity of diastolic dysfunction were excellent (Kappa = 0.93 (0.83–1.00) and 0.88 (0.75–0.99), respectively).

Conclusion

In this validation study within the STANISLAS cohort, diastolic function echocardiographic parameters were found to be highly reproducible. Diastolic dysfunction consequently appears as a highly effective clinical and research tool.  相似文献   

4.

Objectives

Simultaneous Non-contrast Angiography and intraPlaque hemorrhage (SNAP) technique was recently proposed for joint MRA and intraplaque hemorrhage (IPH) imaging. The purpose of this study is to validate SNAP’s MRA performance in patients with suspected intracranial artery disease.

Methods

SNAP and time-of-flight (TOF) techniques with matched field of view and resolution were applied on 15 patients with suspected intracranial artery disease. Both techniques were evaluated based on their detection of luminal stenosis of bilateral middle cerebral arteries (MCA) and the delineation of smallest visible branches (SVB) of the MCA. Statistical analysis was conducted on the artery level.

Results

The SNAP MRA was found to provide similar stenosis detection performance when compared with TOF (Cohen’s κ 0.79; 95% Confidence Interval: 0.56–0.99). For the SVB comparison, SNAP was found to provide significantly better small artery delineation than TOF (p = 0.017). Inter-reader reproducibility for both measurements on SNAP was over 0.7. SNAP also detected IPH lesions on 13% of the patients.

Conclusions

The SNAP technique’s MRA performance was optimized and compared against TOF for intracranial artery atherosclerosis imaging and was found to provide comparable stenosis detection accuracy. Along with its IPH detection capability, SNAP holds the potential to become a first-line screening tool for high risk intracranial atherosclerosis disease evaluation.  相似文献   

5.

Background

Proliferative activity (Ki-67 Labelling Index) in breast cancer increasingly serves as an additional tool in the decision for or against adjuvant chemotherapy in midrange hormone receptor positive breast cancer. Ki-67 Index has been previously shown to suffer from high inter-observer variability especially in midrange (G2) breast carcinomas. In this study we conducted a systematic approach using different Ki-67 assessments on large tissue sections in order to identify the method with the highest reliability and the lowest variability.

Materials and Methods

Five breast pathologists retrospectively analyzed proliferative activity of 50 G2 invasive breast carcinomas using large tissue sections by assessing Ki-67 immunohistochemistry. Ki-67-assessments were done on light microscopy and on digital images following these methods: 1) assessing five regions, 2) assessing only darkly stained nuclei and 3) considering only condensed proliferative areas (‘hotspots’). An individual review (the first described assessment from 2008) was also performed. The assessments on light microscopy were done by estimating. All measurements were performed three times. Inter-observer and intra-observer reliabilities were calculated using the approach proposed by Eliasziw et al. Clinical cutoffs (14% and 20%) were tested using Fleiss’ Kappa.

Results

There was a good intra-observer reliability in 5 of 7 methods (ICC: 0.76–0.89). The two highest inter-observer reliability was fair to moderate (ICC: 0.71 and 0.74) in 2 methods (region-analysis and individual-review) on light microscopy. Fleiss’-kappa-values (14% cut-off) were the highest (moderate) using the original recommendation on light-microscope (Kappa 0.58). Fleiss’ kappa values (20% cut-off) were the highest (Kappa 0.48 each) in analyzing hotspots on light-microscopy and digital-analysis. No methodologies using digital-analysis were superior to the methods on light microscope.

Conclusion

Our results show that all methods on light-microscopy for Ki-67 assessment in large tissue sections resulted in a good intra-observer reliability. Region analysis and individual review (the original recommendation) on light-microscopy yielded the highest inter-observer reliability. These results show slight improvement to previously published data on poor-reproducibility and thus might be a practical-pragmatic way for routine assessment of Ki-67 Index in G2 breast carcinomas.  相似文献   

6.

Purpose

To evaluate a simplified method to measure choroidal thickness (CT) using commercially available enhanced depth imaging (EDI) spectral domain optical coherence tomography (SD-OCT).

Methods

We measured CT in 31 subjects without ocular diseases using Spectralis EDI SD-OCT. The choroid-scleral interface of the acquired images was first enhanced using a post-processing compensation algorithm. The enhanced images were then analysed using Photoshop. Two graders independently graded the images to assess inter-grader reliability. One grader re-graded the images after 2 weeks to determine intra-grader reliability. Statistical analysis was performed using intra-class correlation coefficient (ICC) and Bland-Altman plot analyses.

Results

Using adaptive compensation both the intra-grader reliability (ICC: 0.95 to 0.97) and inter-grader reliability (ICC: 0.93 to 0.97) were perfect for all five locations of CT. However, with the conventional technique of manual CT measurements using built-in callipers provided with the Heidelberg explorer software, the intra- (ICC: 0.87 to 0.94) and inter-grader reliability (ICC: 0.90 to 0.93) for all the measured locations is lower. Using adaptive compensation, the mean differences (95% limits of agreement) for intra- and inter-grader sub-foveal CT measurements were −1.3 (−3.33 to 30.8) µm and −1.2 (−36.6 to 34.2) µm, respectively.

Conclusions

The measurement of CT obtained from EDI SD-OCT using our simplified method was highly reliable and efficient. Our method is an easy and practical approach to improve the quality of choroidal images and the precision of CT measurement.  相似文献   

7.

Purpose

To evaluate the intrasession reproducibility of various thickness parameters used to diagnose and follow-up glaucoma, in particular circumpapillary total retinal thickness (cpTR) provided by the RS-3000 optical coherence tomograph (OCT).

Methods

Fifty-three healthy eyes of 28 subjects underwent three consecutive imaging with the RS-3000 Advance OCT (NIDEK, Aichi,Japan) to evaluate the intrasession reproducibility of circumpapillary total retinal thickness (cpTR), circumpapillary retinal nerve fiber layer thickness (cpRNFL), macular ganglion cell complex thickness (mGCC) and macular total retina thickness (mTR) measurements. Intraclass correlation (ICC), coefficient of variation (CV) and reproducibility coefficient (RC) were calculated for each parameter.

Results

The ICC and CV values for mean cpTR and cpRNFL were 0.987 and 0.897, and 0.60% and 2.81%, respectively. The RC values for the mean cpTR and cpRNFL were 5.95 μm and 9.04 μm, respectively. For all cpTR parameters the ICC values were higher and both the CV and RC values were lower than those for the corresponding cpRNFL parameters. The ICC and CV values for superior mGCC, inferior mGCC, superior mTR and inferior mTR were 0.983, 0.980, 0.983 and 0.988, and 0.84%, 0.98%, 0.48% and 0.43%, respectively. The RC values for superior mGCC, inferior mGCC, superior mTR and inferior mTR were 2.86 μm, 3.12 μm, 4.41μm and 4.43 μm, respectively.

Conclusions

Intrasession reproducibility of cpTR, mGCC and mTR measurements made on healthy eyes was high. Repeatability of cpTR measurements was better than that of the corresponding cpRNFL measurements. These results suggest that future clinical investigations addressing detection of glaucoma and glaucomatous progression with the RS-3000 OCT may benefit from focusing on the cpTR parameters.  相似文献   

8.

Purpose

To evaluate the repeatability and reproducibility of corneal power measurements obtained by Topcon KR-1W and iTrace, and assess the agreement with measurements obtained by Allegro Topolyzer and IOLMaster.

Methods

The right eyes of 100 normal subjects were prospectively scanned 3 times using all the 4 devices. Another observer performed additional 3 consecutive scans using the Topcon KR-1W and iTrace in the same session. About one week later, the first observer repeated the measurements using the Topcon KR-1W and iTrace. The steep keratometry (Ks), flat keratometry (Kf), mean keratometry (Km), J0 and J45 were analyzed. Repeatability and reproducibility of measurements were evaluated by the within-subject standard deviation (Sw), coefficient of variation (CoV), test-retest repeatability (2.77Sw), and intraclass correlation coefficient (ICC). Agreements between devices were assessed using Bland-Altman analysis and 95% limits of agreement (LoA).

Results

Intraobserver repeatability and interobserver and intersession reproducibility of the Ks, Kf and Km showed a CoV of no more than 0.5%, a 2.77Sw of 0.70 D or less, and an ICC of no less than 0.99. However, J0 and J45 showed poor intraobserver repeatability and interobserver and intersession reproducibility (all ICCs not greater than 0.446). Statistically significant differences existed between Topcon KR-1W and IOLMaster, Topcon KR-1W and iTrace, Topcon KR-1W and Topolyzer, iTrace and Topolyzer, iTrace and IOLMaster for Ks, Kf and Km measurements (all P < 0.05). The mean differences between Topcon KR-1W, iTrace, and the other 2 devices were small. The 95% LoA were approximately 1.0 D to 1.5 D for all measurements.

Conclusions

The Ks, Kf and Km obtained by Topcon KR-1W and iTrace showed excellent intraobserver repeatability and interobserver and intersession reproducibility in normal eyes. The agreement between Topcon KR-1W and Topolyzer, Topcon KR-1W and IOLMaster, iTrace and Topolyzer, iTrace and IOLMaster, Topcon KR-1W and iTrace were not so good, they should not be interchangeable in clinical application. Given that the intraobserver repeatability and interobserver and intersession reproducibility of corneal astigmatism measurements obtained by Topcon KR-1W and iTrace were poor, it should be cautious that Topcon KR-1W and iTrace were applied for the preparation of toric lens implantation.  相似文献   

9.

Introduction

The objective of this study is to compare different methods for measuring breast density, both visual assessments and automated volumetric density, in a breast cancer screening setting. These measures could potentially be implemented in future screening programmes, in the context of personalised screening or screening evaluation.

Materials and Methods

Digital mammographic exams (N = 992) of women participating in the Dutch breast cancer screening programme (age 50–75y) in 2013 were included. Breast density was measured in three different ways: BI-RADS density (5th edition) and with two commercially available automated software programs (Quantra and Volpara volumetric density). BI-RADS density (ordinal scale) was assessed by three radiologists. Quantra (v1.3) and Volpara (v1.5.0) provide continuous estimates. Different comparison methods were used, including Bland-Altman plots and correlation coefficients (e.g., intraclass correlation coefficient [ICC]).

Results

Based on the BI-RADS classification, 40.8% of the women had ‘heterogeneously or extremely dense’ breasts. The median volumetric percent density was 12.1% (IQR: 9.6–16.5) for Quantra, which was higher than the Volpara estimate (median 6.6%, IQR: 4.4–10.9). The mean difference between Quantra and Volpara was 5.19% (95% CI: 5.04–5.34) (ICC: 0.64). There was a clear increase in volumetric percent dense volume as BI-RADS density increased. The highest accuracy for predicting the presence of BI-RADS c+d (heterogeneously or extremely dense) was observed with a cut-off value of 8.0% for Volpara and 13.8% for Quantra.

Conclusion

Although there was no perfect agreement, there appeared to be a strong association between all three measures. Both volumetric density measures seem to be usable in breast cancer screening programmes, provided that the required data flow can be realized.  相似文献   

10.

Purpose

To assess wavefront derived refraction and full eye biometry including ciliary muscle dimension and full eye axial geometry in pseudophakic eyes using spectral domain OCT equipped with a Shack-Hartmann wavefront sensor.

Methods

Twenty-eight adult subjects (32 pseudophakic eyes) having recently undergone cataract surgery were enrolled in this study. A custom system combining two optical coherence tomography systems with a Shack-Hartmann wavefront sensor was constructed to image and monitor changes in whole eye biometry, the ciliary muscle and ocular aberration in the pseudophakic eye. A Badal optical channel and a visual target aligning with the wavefront sensor were incorporated into the system for measuring the wavefront-derived refraction. The imaging acquisition was performed twice. The coefficients of repeatability (CoR) and intraclass correlation coefficient (ICC) were calculated.

Results

Images were acquired and processed successfully in all patients. No significant difference was detected between repeated measurements of ciliary muscle dimension, full-eye biometry or defocus aberration. The CoR of full-eye biometry ranged from 0.36% to 3.04% and the ICC ranged from 0.981 to 0.999. The CoR for ciliary muscle dimensions ranged from 12.2% to 41.6% and the ICC ranged from 0.767 to 0.919. The defocus aberrations of the two measurements were 0.443 ± 0.534 D and 0.447 ± 0.586 D and the ICC was 0.951.

Conclusions

The combined system is capable of measuring full eye biometry and refraction with good repeatability. The system is suitable for future investigation of pseudoaccommodation in the pseudophakic eye.  相似文献   

11.

Background

Respiratory rate (RR) is an important vital sign which is strongly correlated with in-hospital mortality. At the same time, RR is the most likely vital sign to be omitted when assessing a patient. We believe that one reason for this could be the difficulty in measure the RR, since it is not read off a monitor, but counted manually. Also there is the possibility of assessment bias and the inter-observer reliability becomes important. We therefore set out to investigate how the nursing staff counting the actual number of respirations per minute would agree with the nursing staff using a predefined ordinal scale.

Methods

For this prospective study, we recorded five videos of a young healthy man breathing approximately 5, 10, 15, 30 and 60 times per minute. The videos were shown in a random order to a suitable sample of the nursing staff. The participants were randomized into two groups; one to count the exact number of breaths per minute, and one to use a predefined ordinal scale.

Results

Comparing the exact number of breaths per minute, the Intra Class Coefficient (ICC) was 0.99 (95% CI: 0.97–1.00). Comparing the RR using the predefined scale, the overall Kappa Fleiss Coefficient was 0.75.

Conclusions

The inter-observer agreement was high when comparing the use of the actual number of breaths per minute and substantial when comparing the use of the predefined scale. This is the largest inter-observer study on RR to date. However, further studies on the use of scaled comparisons of RR are needed.  相似文献   

12.

Objectives

The Japanese Orthopaedic Association (JOA) score is widely used to assess the severity of clinical symptoms in patients with cervical compressive myelopathy, particularly in East Asian countries. In contrast, modified versions of the JOA score are currently accepted as the standard tool for assessment in Western countries. The objective of the present study is to compare these scales and clarify their differences and interchangeability and verify their validity by comparing them to other outcome measures.

Materials and Methods

Five institutions participated in this prospective multicenter observational study. The JOA and modified JOA (mJOA) proposed by Benzel were recorded preoperatively and at three months postoperatively in patients with cervical compressive myelopathy who underwent decompression surgery. Patient reported outcome (PRO) measures, including Japanese Orthopaedic Association Cervical Myelopathy Evaluation Questionnaire (JOACMEQ), the Short Form-12 (SF-12) and the Neck Disability Index (NDI), were also recorded. The preoperative JOA score and mJOA score were compared to each other and the PRO values. A Bland-Altman analysis was performed to investigate their limits of agreement.

Results

A total of ninety-two patients were included. The correlation coefficient (Spearman’s rho) between the JOA and mJOA was 0.87. In contrast, the correlations between JOA/mJOA and the other PRO values were moderate (|rho| = 0.03 – 0.51). The correlation coefficient of the recovery rate between the JOA and mJOA was 0.75. The Bland-Altman analyses showed that limits of agreement were 3.6 to -1.2 for the total score, and 55.1% to -68.8% for the recovery rates.

Conclusions

In the present study, the JOA score and the mJOA score showed good correlation with each other in terms of their total scores and recovery rates. Previous studies using the JOA can be interpreted based on the mJOA; however it is not ideal to use them interchangeably. The validity of both scores was demonstrated by comparing these values to the PRO values.  相似文献   

13.

Background

Peak oxygen uptake (VO2peak) via cardiopulmonary exercise testing is considered the gold standard for testing aerobic capacity in healthy participants and people with various medical conditions. The reliability and responsiveness of cardiopulmonary exercise testing outcomes in persons with MS (PwMS) have not been extensively studied.

Objective

(1) to investigate the reliability of cardiopulmonary exercise parameters in PwMS; (2) to determine the responsiveness, in terms of the smallest detectable change (SDC), for each parameter.

Design

Two repeated measurements of cardiopulmonary exercise outcomes were obtained, with a median time interval of 16 days.

Methods

Thirty-two PwMS suffering from subjective fatigue performed cardiopulmonary exercise tests on a cycle ergometer, to voluntary exhaustion. We calculated the reliability, in terms of the intra-class correlation coefficient (ICC [2,k]; absolute agreement), and the measurement error, in terms of standard error of measurement (SEM) and SDC at individual (SDCindividual) and group level (SDCgroup).

Results

The ICC for VO2peak was 0.951, with an SEM of 0.131 L∙min−1 and an SDCindividual of 0.364 L∙min−1. When corrected for bodyweight, the ICC of VO2peak was 0.933, with an SEM of 1.7 mL∙kg−1∙min−1 and in an SDCindividual of 4.6 mL∙kg−1∙min−1.

Limitations

Generalization of our study results is restricted to fatigued PwMS with a low to mild level of disability.

Conclusions

At individual level, cardiopulmonary exercise testing can be used reliably to assess physical fitness in terms of VO2peak, but less so to determine significant changes. At group level, VO2peak can be reliably used to determine physical fitness status and establish change over time.  相似文献   

14.

Objective

Multiple Sclerosis Spasticity Scale (MSSS)-88 has been developed for self-assessment of spasticity symptoms in patients with multiple sclerosis (MS). The objective of this study was to validate MSSS-88 and evaluate the psychometric properties in patients with MS in Serbia.

Methods

The study comprised 65 MS patients with spasticity. MSSS-88 consists of 88 items grouped in eight sections. Internal consistency of the MSSS-88SR subscales was determined using Cronbach’s alpha coefficient. Test/retest reliability with an intra-class correlation coefficient (ICC) for each MSSS-88SR subscale was performed. Clinical validity of MSSS-88SR was determined by correlations with the Numeric Rating Scale (NRS) and the Modified Ashworth Scale (MAS).

Results

The range of Cronbach’s alpha for all scales and ICC was 0.91–0.96 and 0.84–0.91, respectively. All ICCs were statistically significant (p<0.05). All evaluated subscales of MSSS-88 were significantly correlated with the NRS scale. The highest correlation coefficients were registered between the WL subscale and the EDSS and MAS, while the strongest relationship was observed between the MSS subscale and the NRS.

Conclusion

The Serbian translated version of this instrument may be useful as a clinical measure for spasticity and functionality in patients with MS.  相似文献   

15.

Objective

To study the normal values of the retinal oxygen saturation in Rhesus monkeys and to evaluated repeatability and reproducibility of retinal oxygen saturation measurements.

Methods

Eighteen adult Rhesus macaque monkeys were included in this experimental study. An Oxymap T1 retinal oximeter (Oxymap, Reykjavik, Iceland) was used to perform oximetry on all subjects. Global arterial (SaO2) and venous oxygen saturation (SvO2), arteriovenous difference in SO2 were measured. In the first examination, each eye was imaged three times. At the following two examinations, each eye was imaged once. All examinations were finished in one month. P values were calculated to evaluate the difference between the measurements during three visits by performing an ANOVA. Intra-visit and inter-visit intraclass correlation coefficient (ICC) was determined.

Results

At baseline, the average SaO2 and SvO2 were 89.48 ± 2.64% and 54.85 ± 2.18%, respectively. The global A-V difference was 34.63 ± 1.91%. The difference between the three visits was not significant (p>0.05). The highest A-V difference in SO2 and lowest saturations were found in the inferotemporal quadrant. Intra-session and inter-visit repeatability were both high. For all oxygen saturation parameters, the ICC values of the intra-session repeatability ranged between 0.92 and 0.96. As found previously, a relatively high ICC value for inter-visit repeatability also was found for all oxygen saturation measurements, ranging between 0.86 and 0.94, with the lowest values in the infero-nasal quadrant.

Conclusions

Our study is the first to describe retinal SO2 in healthy Rhesus monkeys. In normal monkey eyes, the reproducibility and repeatability of retinal oximetry oxygen saturation measurements were high in the retinal arterioles and venules. Our results support that Oxymap T1 retinal oximetry is a suitable and reliable technique in monkey studies.  相似文献   

16.

Background

Ki67 labeling index (LI) is used as a predictive marker and is associated with prognosis in breast cancer. However, standardised methodologies for measurement are lacking which has limited its application in clinical practice. In this study, we evaluated the interobserver concordance of visual assessment of Ki67 LI in breast cancer.

Methods

Ki67- immunostained slides of 160 cases of primary invasive breast cancer were visual assessed by five breast pathologists with two different methods to choose the scoring fields: (1) hot-spot score, (2) average score. Proportions of positive invasive tumor cells at 10 % intervals were scored. The intra-class correlation coefficient (ICC) was used to assess the interobserver reproducibility.

Results

(1) A perfect concordance of Ki67 LI was demonstrated according to both score methods (P<0.0001). Average score method (ICC, 0.904) demonstrated a better correlation than hot-spot score method (ICC, 0.894). (2) By respective means according to two score methods, all cases were classified into three groups (≤10%, 11%-30% and >30% Ki-67 LI). The concordance was relatively low in intermediate Ki67 LI group compared with low and high Ki67 LI groups. (3) All cases were classified into three groups by paired-difference (d) between means of hot-spot score and average score (d<5, 5≤d<10, d≥10). The consistency was observed to decrease with increasing paired-difference according to both methods.

Conclusions

Visual assessment of Ki67 LI at 10 % intervals is a candidate for a standard method in breast cancer clinical practice. Average score and hot-spot score of visual assessment both demonstrated a perfect concordance, and an overall average assessment across the whole section including hot spots may be a better method. Interobserver concordance of intermediate Ki67 LI in which most cutoffs are located for making clinical decisions was relatively low.  相似文献   

17.

Purpose

To describe a novel method for quantitative measurement of area parameters in ocular anterior segment ultrasound biomicroscopy (UBM) images using Photoshop software and to assess its intraobserver and interobserver reproducibility.

Methods

Twenty healthy volunteers with wide angles and twenty patients with narrow or closed angles were consecutively recruited. UBM images were obtained and analyzed using Photoshop software by two physicians with different-level training on two occasions. Borders of anterior segment structures including cornea, iris, lens, and zonules in the UBM image were semi-automatically defined by the Magnetic Lasso Tool in the Photoshop software according to the pixel contrast and modified by the observers. Anterior chamber area (ACA), posterior chamber area (PCA), iris cross-section area (ICA) and angle recess area (ARA) were drawn and measured. The intraobserver and interobserver reproducibilities of the anterior segment area parameters and scleral spur location were assessed by limits of agreement, coefficient of variation (CV), and intraclass correlation coefficient (ICC).

Results

All of the parameters were successfully measured by Photoshop. The intraobserver and interobserver reproducibilities of ACA, PCA, and ICA were good, with no more than 5% CV and more than 0.95 ICC, while the CVs of ARA were within 20%. The intraobserver and interobserver reproducibilities for defining the spur location were more than 0.97 ICCs. Although the operating times for both observers were less than 3 minutes per image, there was significant difference in the measuring time between two observers with different levels of training (p<0.001).

Conclusion

Measurements of ocular anterior segment areas on UBM images by Photoshop showed good intraobserver and interobserver reproducibilties. The methodology was easy to adopt and effective in measuring.  相似文献   

18.

Background

Ki67 labeling index (LI) is critical for treatment options and prognosis evaluation in breast cancer. Visual assessment (VA) is widely used to assess Ki67 LI, but has some limitations. In this study, we compared the consistency between VA and automated digital image analysis (DIA) of Ki67 LI in breast cancer, and to evaluate the application value of DIA in Ki67 LI assessment.

Methods

Ki67 immunostained slides of 155 cases of primary invasive breast cancer were eyeballing assessed by five breast pathologists and automated digital image analyzed by one breast pathologist respectively. Two score methods, hot-spot score and average score, were used to choose score areas. The intra-class correlation coefficient (ICC) was used to analyze the consistency between VA and DIA, and Wilcoxon signed-rank test was used to compare the median of paired-difference between VA and DIA values.

Results

(1) A perfect agreement was demonstrated between VA and DIA of Ki67 LI by ICC analysis (P<0.0001) in the whole cohort. A perfect agreement between VA and DIA of Ki67 LI was also showed in G2-G3, ER positive/HER2 negative cases. Average score and hot-spot score methods both demonstrated a perfect concordance between VA and DIA of Ki67 LI. (2) All cases were classified into three groups by VA values (≤10%, 11%-30% and >30% Ki67 LI). The concordance was relatively lower in intermediate Ki67 LI group (11%-30%) compared with high (>30%) Ki67 LI groups according to both methods. (3) All cases were classified into three groups by paired-difference (d) between VA values of hot-spot score and average score (d<5, 5≤d<10, d≥10) to evaluate the correlation between Ki67 staining distribution (heterogeneous or homogenous) and reproducibility of assessment. A perfect agreement was all demonstrated in three groups, and a slightly better Ki67 LI agreement between VA and DIA was indicated in homogenous staining slides than in heterogeneous staining ones. (4) VA values were relatively smaller than DIA values (average score: median of paired-difference -3.72; hot-spot score: median of paired-difference -9.12).

Conclusions

An excellent agreement between VA and DIA of Ki67 LI in breast cancer was demonstrated in the whole mixed cohort, suggesting that VA and DIA both could be used to assess Ki67 LI in clinical practice. Average score and hot-spot score methods both demonstrated a perfect concordance between VA and DIA of Ki67 LI. The almost perfect agreement between VA and DIA was observed in high Ki67 LI cases, displaying a homogenous staining pattern. The consistency between VA and DIA was relatively low in intermediate Ki67 LI group. The heterogeneity of tumors may slightly affect the concordance between VA and DIA of Ki67 LI. Assessment of VA provides lower Ki67 values than DIA, the biological importance of these values are not known at the moment.  相似文献   

19.

Background and Objective

The STarT Back Tool uses prognostic indicators to classify patients with low back pain into three risk groups to guide early secondary prevention in primary care. The present study aimed to evaluate the psychometric properties of the Japanese version of the tool (STarT-J).

Methods

An online survey was conducted among Japanese patients with low back pain aged 20–64 years. Reliability was assessed by examining the internal consistency of the overall and psychosocial subscales using Cronbach’s alpha coefficients. Spearman’s correlation coefficients were used to evaluate the concurrent validity between the STarT-J total score/psychosocial subscore and standard reference questionnaires. Discriminant validity was evaluated by calculating the area under the curves (AUCs) for the total and psychosocial subscale scores against standard reference cases. Known-groups validity was assessed by examining the relationship between low back pain-related disability and STarT-J scores.

Results

The analysis included data for 2000 Japanese patients with low back pain; the mean (standard deviation [SD]) age was 47.7 (9.3) years, and 54.1% were male. The mean (SD) STarT-J score was 2.2 (2.1). The Cronbach’s alpha coefficient was 0.75 for the overall scale and 0.66 for the psychosocial subscale. Spearman’s correlation coefficients ranged from 0.30 to 0.59, demonstrating moderate to strong concurrent validity. The AUCs for the total score ranged from 0.65 to 0.83, mostly demonstrating acceptable discriminative ability. For known-groups validity, participants with more somatic symptoms had higher total scores. Those in higher STarT-J risk groups had experienced more low back pain-related absences.

Conclusions

The overall STarT-J scale was internally consistent and had acceptable concurrent, discriminant, and known-groups validity. The STarT-J can be used with Japanese patients with low back pain.  相似文献   

20.

Background and Purpose

Good reliability of methods to assess the extent of ischemia in acute stroke is important for implementation in clinical practice, especially between observers with varying experience. Our aim was to determine inter- and intra-observer reliability of the 1/3 middle cerebral artery (MCA) rule and the Alberta Stroke Program Early CT Score (ASPECTS) for different CT modalities in patients suspected of acute ischemic stroke.

Methods

We prospectively included 105 patients with acute neurological deficit due to suspected acute ischemic stroke within 9 hours after symptom onset. All patients underwent non-contrast CT, CT perfusion and CT angiography on admission. All images were evaluated twice for presence of ischemia, ischemia with >1/3 MCA involvement, and ASPECTS. Four observers evaluated twenty scans twice for intra-observer agreement. We used kappa statistics and intraclass correlation coefficient to calculate agreement.

Results

Inter-observer agreement for the 1/3 MCA rule and ASPECTS was fair to good for non-contrast CT, poor to good for CT angiography source images, but excellent for all CT perfusion maps (cerebral blood volume, mean transit time, and predicted penumbra and infarct maps). Intra-observer agreement for the 1/3 MCA rule and ASPECTS was poor to good for non-contrast CT, fair to moderate for CT angiography source images, and good to excellent for all CT perfusion maps.

Conclusion

Between observers with a different level of experience, agreement on the radiological diagnosis of cerebral ischemia is much better for CT perfusion than for non-contrast CT and CT angiography source images, and therefore CT perfusion is a very reliable addition to standard stroke imaging.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号