首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 281 毫秒
1.
A novel amperometric lactate biosensor was developed based on immobilization of lactate dehydrogenase onto graphene oxide nanoparticles‐decorated pencil graphite electrode. The enzyme electrode was characterized by scanning electron microscopy, Fourier transform infrared spectroscopy (FTIR), and cyclic voltammetry at different stages of its construction. The biosensor showed optimum response within 5 s at pH 7.3 (0.1 M sodium phosphate buffer) and 35°C, when operated at 0.7 V. The biosensor exhibited excellent sensitivity (detection limit as low as 0.1 μM), fast response time (5 s), and wider linear range (5–50 mM). Analytical recovery of added lactic acid in serum was between 95.81–97.87% and within‐batch and between‐batch coefficients of variation were 5.04 and 5.40%, respectively. There was a good correlation between serum lactate values obtained by standard colorimetric method and the present biosensor (r = 0.99). The biosensor measured lactate levels in sera of apparently healthy subjects and persons suffering from lactate acidosis and other biological materials (milk, curd, yogurt, beer, white wine, and red wine). The enzyme electrode lost 25% of its initial activity after 60 days of its regular uses, when stored dry at 4°C.  相似文献   

2.
Abstract

This work describes, for the first time, the fabrication of poly(L-aspartic acid) (PAA) film modified pencil graphite electrode (PGE) for the detection of hepatitis C Virus 1a (HCV1a). The presence of PAA on the electrode surface can provide free carboxyl groups for covalent binding of biomolecules. The PGE surface was first coated with PAA via electropolymerization of the L-aspartic acid, and avidin was subsequently attached to the PAA modified electrode by covalent attachment. Biotinylated HCV1a probes were immobilized on avidin/PAA/PGE via avidin-biotin interaction. The morphology of PAA/PGE was examined using a scanning electron microscope. The hybridization events were monitored with square wave voltammetry using Meldola’s blue (MDB). Compared to non-complementary oligonucleotide sequences, when hybridization was carried out between the probe and its synthetic targets or the synthetic polymerase chain reaction analog of HCV1a, the highest MDB signal was observed. The linear range of the biosensor was 12.5 to 100?nM and limit of detection was calculated as 8.7?nM. The biosensor exhibited favorable stability over relatively long-term storage. All these results suggest that PAA-modified electrode can be used to nucleic acid biosensor application and electropolymerization of L-aspartic acid can be considered as a good candidate for the immobilization of biomolecules.  相似文献   

3.
Biosensors containing recombinant carbohydrate oxidase from Microdochium nivale (rMnO) were developed by means of either chemically modified carbon paste or graphite electrode. 1-(N,N-dimethylamine)-4-(4-morpholine)benzene (AMB) and 1,1'-dimethylferrocene (DMFc) have been used as mediators. The biosensors showed a linear calibration graph up to 18 mM of glucose when operated at 0.04-0.36 V versus a saturated calomel electrode. Almost no change was detected in the sensitivity of the biosensors at pH 7.2-8.1. The biosensors responded to other aldoses in the D-configuration, however, maximal sensitivity of the biosensor was towards D-glucose. The biosensor did not response to polyhydroxylic compounds such as D-mannitol, D-sorbitol and inositol. The advantages of the biosensors based on rMnO in comparison to Aspergillus niger glucose oxidase is a wider linear range, low sensitivity to oxygen and (in some cases) broad specificity.  相似文献   

4.
The novel putrescine oxidase based amperometric biosensor selectively measures putrescine, which can be considered as an indicator of microbial spoilage. Putrescine oxidase (PUOX, EC 1.4.3.10) was isolated from Kocuria rosea (Micrococcus rubens) by an improved and simplified purification process. Cells were grown on brain heart infusion medium supplemented with putrescine. Cell-free extract was prepared in Tris buffer (pH 8.0) by Bead-beater. A newly elaborated step based on three-phase partitioning (TPP) was applied in the purification protocol of PUOX. The purified enzyme was immobilized on the surface of a spectroscopic graphite electrode in redox hydrogel with horseradish peroxidase, Os mediator and poly(ethylene glycol) (400) diglycidyl ether (PEGDGE) as crosslinking agent. This modified working electrode was used in wall-jet type amperometric cell together with the Ag/AgCl (0.1M KCl) reference electrode and a platinum wire as auxiliary electrode in flow injection analysis system (FIA). Hydrogel composition, pH and potential dependence were studied. Optimal working conditions were 0.45mLmin(-1) flow rate of phosphate buffer (66mM, pH 8.0) and +50mV polarizing potential vs. Ag/AgCl. The linear measuring range of the method was 0.01-0.25mM putrescine, while the detection limit was 5μM. Beer samples were investigated by the putrescine biosensor and the results were compared by those of HPLC reference method.  相似文献   

5.
We describe the amplification of amperometric l-lysine biosensor using l-lysine oxidase nanoparticles (LOxNPs) and graphene oxide nanoparticles (GrONPs) immobilized onto pencil graphite electrode (PGE). LOxNPs and GrONPs were characterized by UV spectroscopy and transmission electron microscopy (TEM). The working electrode (LOxNPs/GrONPs/PGE) was studied by scanning electron microscopy (SEM) and cyclic voltammetry at different stages of its construction. The biosensor showed optimum current at 0.7 V, pH 6.5, 35 °C, a detection limit of 0.01 μM, response time as 3.95 s and a wider linear range 0.01–1000 μM. The analytical recovery of added lysine in sera was 97 %. The within assay and between batch coefficients of variation for the biosensor were 0.068 and 0.074 % respectively. The biosensor measured l-lysine levels in sera of healthy adults and human immunodeficiency virus (HIV) patients. The biosensor exhibited good correlation with standard spectrophotometric method (R2 = 0.989). The biosensor lost 35 % of its original activity after its regular uses for a period of 180 days, while being stored dry at 4 °C.  相似文献   

6.
The storage stability of amperometric enzyme electrodes has been enhanced by a combination of a soluble, positively charged polymer, diethylaminoethyl (DEAE)-dextran, and a sugar alcohol, lactitol. Two different types of alcohol biosensor have been produced using the enzyme alcohol oxidase, isolated from the methylotrophic yeast Hansenula polymorpha. The first employs enzyme entrapment between two membranes with direct hydrogen peroxide amperometry at +0·65 V. The second was based on the mediated, coupled reaction with horseradish peroxidase and N-methyl phenazimiumtetracyanoquinonedimethane (NMP-TCNQ) on a graphite electrode. In both cases, addition of the stabilizers promoted a considerable increase in the storage stability of the enzyme component, as indicated by an increase in the shelf life of desiccated biosensors under conditions of thermal stress at 37°C. In addition, an L-glutamate biosensor constructed from NMP-TCNQ-modified graphite electrodes and L-glutamate oxidase also exhibited an increase in shelf life when stored, desiccated in the presence of stabilizers.  相似文献   

7.
The hydrophobic carbon nanotubes-ionic liquid (CNTs-IL) gel forms a stable modified film on hydrophobic graphite electrode surface. Laccase immobilized on the CNTs-IL gel film modified electrode shows good thermal stability and enhanced electrochemical catalytic ability. The optimal bioactivity occurs with increasing temperature and this optimum is 20 degrees C higher in comparison to free laccase. The improvement of laccase thermal stability may be due to the microenvironment of hydrophobic CNTs-IL gel on graphite electrode surface. On the other hand, the sensitive detection of oxygen has been achieved due to the feasibility of oxygen reduction by both of laccase and nanocomposite of CNTs-IL gel. Furthermore, the laccase hybrid nanocomposite also shows the fast electrochemical response and high sensitivity to the inhibitors of halide ions with the approximate IC50 of 0.01, 4.2 and 87.5 mM for the fluoride, chloride and bromide ions, respectively. It implies the feasibility of laccase modified electrode as an inhibition biosensor to detect the modulators of laccase.  相似文献   

8.
A bi-enzymatic biosensor for monitoring of dihydroxyacetone production during oxidation of glycerol by bacterial cells of Gluconobacter oxydans is presented. Galactose oxidase oxidizes dihydroxyacetone efficiently producing hydrogen peroxide, which reacts with co-immobilized peroxidase and ferrocene pre-adsorbed on graphite electrode. This mediator-based bi-enzymatic biosensor possesses very high sensitivity (4.7 μA/mM in phosphate buffer), low detection limit (0.8 μM, signal/noise = 3), short response time (22 s, 95% of steady-state) and broad linear range (0.002-0.55 mM in phosphate buffer). The effect of pH, temperature, type of buffer, as well as different stabilizers (combinations of a polyelectrolyte and a polyol) on the sensor performance were carefully optimized and discussed. Dihydroxyacetone produced during a batch conversion of glycerol by the pectate-immobilized bacteria in an air-lift reactor was determined by the biosensor and by reference spectrophotometric method. Both methods were compared and were in a very good correlation. The main advantage of the biosensor is a very short time needed for sample analysis (less than 1 min).  相似文献   

9.
A direct electrochemical DNA biosensor based on zero current potentiometry was fabricated by immobilization of ssDNA onto gold nanoparticles (AuNPs) coated pencil graphite electrode (PGE). One ssDNA/AuNPs/PGE was connected in series between clips of working and counter electrodes of a potentiostat, and then immersed into the solution together with a reference electrode, establishing a novel DNA biosensor for specific DNA detection. The variation of zero current potential difference (ΔE(zcp)) before and after hybridization of the self-assembled probe DNA with the target DNA was used as a signal to characterize and quantify the target DNA sequence. The whole DNA biosensor fabrication process was characterized by cyclic voltammetry and electrochemical impedance spectroscopy with the use of ferricyanide as an electrochemical redox indicator. Under the optimized conditions, ΔE(zcp) was linear with the concentrations of the complementary target DNA in the range from 10nM to 1μM, with a detection limit of 6.9nM. The DNA biosensor showed a good reproducibility and selectivity. Prepared DNA biosensor is facile and sensitive, and it eliminates the need of using exogenous reagents to monitor the oligonucleotides hybridization.  相似文献   

10.
The electrochemical performance of a new glucose biosensor is reported. The glucose biosensor is developed using glucose oxidase (GOD) and ferrocene encapsulated palladium (Pd)-linked organically modified sol-gel glass (ORMOSIL) material incorporated within graphite paste electrode. The ORMOSIL material incorporated within graphite paste electrode behaves as an excellent electrocatalyst for the oxidation of enzymatically reduced GOD. The electrochemical behavior of new glucose biosensor has been examined by cyclic volammetry and amperometric measurements. The bioelectrocatalysis of ORMOSIL embedded within graphite paste as a function of storage time and varying concentration of ORMOSIL is reported. The initial amperometric response on glucose sensing is recorded to be 145 microA at 15% (w/w) concentration of the ORMOSIL which is decreased to 20 microA at 5% of the same keeping GOD concentration constant. The variation of electrochemical behavior of the ORMOSIL embedded within graphite paste as a function of time has also been studied based on cyclic voltammetry. The voltammograms showing the reversible electrochemistry of ORMOSIL encapsulated ferrocene is changed into a plateau shape as a function of time, however, the electrocatalytic behavior is still retained. The practical usability of new glucose sensor has been compared with earlier developed glucose sensor. The sensitivity, response time and linearity of the new glucose biosensor are found to be excellent over earlier reported glucose biosensor. The amperometric response, calibration curve and practical applications of new glucose sensor are reported.  相似文献   

11.
A biosensor for the detection of triazine- and phenylurea-type herbicides was constructed using isolated Photosystem II (PS II) complexes as a biosensing element. PSII isolated from the thermophilic cyanobacterium Synechococcus elongatus was immobilized on the surface of a screen-printed sensor composed of a graphite working electrode and Ag/AgCl reference electrode deposited on a polymeric substrate. The biosensor was mounted in a flow microcell with illumination. The principle of the detection was based on the fact that herbicides selectively block PSII electron transport activity in a concentration-dependent manner. Changes of the activity were registered amperometrically as the rate of photoreduction of an artificial electron acceptor. The setup resulted in a reusable herbicide biosensor with a good stability (half-life of 24 h) and limit of detection of approximately 10(-9) M for diuron, atrazine and simazine.  相似文献   

12.
A biosensor for glucose using glucose dehydrogenase immobilized on a chemically modified graphite electrode was supplied with coenzyme, nicotinamide adenine dinucleotide (NAD+), through pores in the material. A graphite rod was hollowed out, leaving 0.3 mm at the end contacting the solution, filled with 10 mM NAD+ and pressurized. The response factor was 40% of that obtained when 2 mM NAD+ was mixed with the sample solution in a flow system. The coenzyme consumption was 11 microliters h-1 representing a 500-fold saving compared to supply through the bulk solution. The biosensor had a linear calibration curve from the detection limit, 1 microM, to 2 mM glucose and a repeatability of 0.3%. The graphite electrode was modified by adsorption of a bis-(benzophenoxazinyl)-terephthaloyl derivative in order to be able to oxidize NADH at 0 mV versus Ag/AgCl, 0.1 M KCl.  相似文献   

13.
Commercial enzymes, creatininase (CA) from Pseudomonas sp, creatinase (CI) from Pseudomonas sp, sarcosine oxidase (SO) from Bacillus sp were co-immobilized onto iron oxide nanoparticles/chitosan-graft-polyaniline (Fe(3)O(4)-NPs/CHIT-g-PANI) composite film electrodeposited on surface of Pt electrode through glutaraldehyde coupling. Transmission electron microscopy (TEM) was used for characterization of Fe(3)O(4)-NPs. A creatinine biosensor was fabricated using Enzymes/Fe(3)O(4)-NPs/CHIT-g-PANI/Pt electrode as working electrode, Ag/AgCl as reference electrode and Pt wire as auxiliary electrode. The enzyme electrode was characterized by cyclic voltammetry (CV), scanning electron microscopy (SEM), Fourier transform infrared (FTIR) spectroscopic and electrochemical impedance spectroscopy (EIS). The biosensor exhibited an optimum response within 2s at pH 7.5 and 30 °C, when polarized at 0.4V vs Ag/AgCl. The electrocatalytic response showed a linear dependence on creatinine concentration ranging from 1 to 800 μM. The sensitivity of the biosensor was 3.9 μA μM(-1) cm(-2), with a detection limit of 1 μM (S/N=3). Apparent Michaelis-Menton (K(m)) value for creatinine was 0.17 mM. The biosensor showed only 10% loss in its initial response after 120 uses over 200 days, when stored at 4 °C. The biosensor measured creatinine in the serum of apparently healthy persons which correlated well with a standard colorimetric method (r=0.99).  相似文献   

14.
We attempted to develop a screen-printed biosensor for the amperometric determination of L-lactate dehydrogenase (LDH) level on the basis of NAD(+)/NADH-dependent dehydrogenase reaction. The printing ink for the working electrode consisted of L-lactate, NAD(+), composite polymer of hydroxyethyl cellulose with ethylene glycol, 3,4-dihydroxybenzaldehyde (3,4-DHB) as an electron transferring mediator, and graphite as the conducting material. The 3,4-DHB was electropolymerized on the carboneous working electrode by potential cycling between -200 and +300 mV vs. Ag/AgCl reference electrode. Through the electrocatalytic reaction with immobilized 3,4-DHB, the NADH generated by the LDH reaction could be efficiently oxidized at lower potential than the unmodified carbon electrode. The analytical performance of the electrode was characterized in terms of linear sensing range and detection limit for LDH. The response from the developed biosensor was linear up to 500 U/l of LDH, and the detection limit of 50 U/l was observed at the signal-to-noise ratio of 3.  相似文献   

15.
In this study, a 15-lipoxygenase-modified carbon paste electrode (15-LOX-MCPE) was developed in connection with the help of voltammetry, which can be used as an assay system for screening drugs with inhibiting lipoxygenase (LOX) activity. The influence of different experimental conditions (LOX loading of carbon paste, pH, type of buffer system etc.) was investigated in order to optimise the biosensing device. The best composition of the biosensor is 30% paraffin oil, 68% graphite powder and 2% LOX. The optimised voltammetric measurement medium is S?rensen/NaOH (0.1M, pH 9.0) using linoleic acid as a substrate. Under these conditions the hydroperoxy linoleic acid is formed, which can be oxidised at a potential of +0.9 V versus Ag/AgCl/3M KCl. The applicability of the LOX biosensor as assay of lipoxygenase inhibitors was successfully tested with nordihydroguaiaretic acid, zileuton and fenleuton, which are well known inhibitors of LOX.  相似文献   

16.
This present study was aimed to fabricate a sensitive and improved amperometric biosensor by the nanoparticles of pyruvate oxidase, which were prepared and immobilized covalently onto pencil graphite electrode. The biosensor showed ideal working within 5 s under defined conditions of pH 6.0 and incubation temperature of 30 °C at an applied voltage of -0.1 V. Under standard assay conditions, a linear response was obtained between pyruvate concentration ranging from 0.001 to 6000 μM and current (μA). A lower detection limit (0.58 μM) and an excellent correlation coefficient (R2 = 0.999) with standard spectrophotometric assay was obtained for the present biosensor. Within and between batches of coefficients of variation were calculated and found to be 3.61 % and 3.33 %, respectively. The biosensor was put to continual use for over 210 days. The biosensor was employed for the measurement of pyruvate level in sera of normal healthy individuals and persons suffering from heart disease.  相似文献   

17.
A new method has been developed to incorporate the mediator, tetrathiafulvalene (TTF), to the electrode/solution interface of an amperometric biosensor. TTF was dissolved in methylphenyl polysiloxane (silicone oil) and embedded in a graphite disc electrode. The mediator was able to diffuse to the electrode surface at an electrocatalytically significant speed. The storage of TTF in the inert polysiloxane provided a long-lasting and stable mediator supply.

TTF-silicone oil electrodes with immobilized glucose oxidase, xanthine oxidase, or amino acid oxidase exhibited sensitive, fast and reproducible responses. The glucose oxidase electrode was very stable for at least 2 months when stored at 4°C. Together with flow injection analysis (FIA), the enzyme electrodes were reused for at least 500 repeated analyses during a 25 h operation without losing their initial activity.  相似文献   


18.
An electrochemical genosensor for the detection of hypermethylation of the glutathione S-transferase P1 (GSTP1) gene, a specific marker of prostate cancer, was reported. This new sensor was used in combination with a single-use carbon graphite working electrode and differential pulse voltammetry, with the results of sample analysis based on the guanine oxidation signals obtained at +1.0 V before and after hybridization between probe and synthetic target or denatured PCR samples. The detected DNA hybridization was also characterized by electrochemical impedance spectroscopy with potassium ferri/ferrocyanide as a redox probe. The protocol consisted of 2 different modes: (i) capture probes selective for methylation-specific and unmethylated GSTP1 sequences were immobilized onto the sensor directly, and hybridization was formed on the electrode surface; (ii) probe/target or probe/noncomplementary target couples were mixed in solution phase, and the transducer was modified through simple adsorption. The limit of detection (S/N=3) was calculated as 2.92 pmol of target sequence in a 100-μl reaction volume. The optimum analytical detection parameters for the biosensor, as well as its future prospects, were also presented.  相似文献   

19.
The electrochemical behavior of L-cysteine (CySH) on platinum (Pt)/carbon nanotube (CNT) electrode was investigated by cyclic voltammetry. CNTs used in this study were grown directly on graphite disk by chemical vapor deposition. Pt was electrochemically deposited on the activated CNT/graphite electrode by electroreduction of Pt(IV) complex ion on the surface of CNTs. Among graphite, CNT/graphite, and Pt/CNT electrodes, improved electrochemical behavior of CySH oxidation was found with Pt/CNT electrode. On the other hand, a sensitive CySH sensor was developed based on Pt/CNT/graphite electrode. A linear calibration curve can be observed in the range of 0.5 microM-0.1 mM. The detection limit of the Pt/CNT electrode is 0.3 microM (signal/nose=3). Effects of pH, scan rate, and interference of other oxidizable amino acids were also investigated and discussed. Additionally, the reproducibility, stability, and applicability of the Pt/CNT electrode were evaluated.  相似文献   

20.
Cells of Zymomonas mobilis were permeabilized with toluene in order to utilize the enzymes, glucose-fructose oxidoreductase and gluconolactonase, inside the intact cells. Permeabilized cells were immobilized in a gelatin membrane, and a whole cell enzyme electrode was constructed by fixing the membrane on pH electrode. The biosensor developed was used for specific determination of glucose or fructose by detecting the production rate of hydrogen ion. Optimum conditions for biosensor response were pH 6.2 and temperature of 39 degrees C. The biosensor was highly specific and reproducible, and calibration curves for glucose and fructose were excellent, being linear up to 5 and 50 g/L, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号