首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Microporous filters that are more electropositive than the negatively charged filters currently used for virus concentrations from water by filter adsorption-elution methods were evaluated for poliovirus recovery from tap water. Zeta Plus filters composed of diatomaceous earth-cellulose-"charge-modified" resin mixtures and having a net positive charge of up to pH 5 to 6 efficiently adsorbed poliovirus from tap water at ambient pH levels 7.0 to 7.5 without added multivalent cation salts. The adsorbed virus were eluted with glycine-NaOH, pH 9.5 to 11.5. Electropositive asbestos-cellulose filters efficiently adsorbed poliovirus from tap water without added multivalent cation salts between pH 3.5 and 9.0, and the absorbed viruses could be eluted with 3% beef extract, pH 9, but not with pH 9.5 to 11.5 glycine-NaOH. Under water quality conditions in which poliovirus recoveries from large volumes of water were less than 5% with conventional negatively charged filters and standard methods, recoveries with Zeta Plus filters averaged 64 and 22.5% for one- and two-stage concentration procedures, respectively. Electropositive filters appear to offer distinct advantages over conventional negatively charged filters for concentrating enteric viruses from water, and their behavior tends to confirm the importance of electrostatic forces in virus recovery from water by microporous filter adsorption-elution methods.  相似文献   

2.
Microporous filters that are more electropositive than the negatively charged filters currently used for virus concentrations from water by filter adsorption-elution methods were evaluated for poliovirus recovery from tap water. Zeta Plus filters composed of diatomaceous earth-cellulose-"charge-modified" resin mixtures and having a net positive charge of up to pH 5 to 6 efficiently adsorbed poliovirus from tap water at ambient pH levels 7.0 to 7.5 without added multivalent cation salts. The adsorbed virus were eluted with glycine-NaOH, pH 9.5 to 11.5. Electropositive asbestos-cellulose filters efficiently adsorbed poliovirus from tap water without added multivalent cation salts between pH 3.5 and 9.0, and the absorbed viruses could be eluted with 3% beef extract, pH 9, but not with pH 9.5 to 11.5 glycine-NaOH. Under water quality conditions in which poliovirus recoveries from large volumes of water were less than 5% with conventional negatively charged filters and standard methods, recoveries with Zeta Plus filters averaged 64 and 22.5% for one- and two-stage concentration procedures, respectively. Electropositive filters appear to offer distinct advantages over conventional negatively charged filters for concentrating enteric viruses from water, and their behavior tends to confirm the importance of electrostatic forces in virus recovery from water by microporous filter adsorption-elution methods.  相似文献   

3.
Concentration of Enteroviruses on Membrane Filters   总被引:35,自引:3,他引:32       下载免费PDF全文
Enteroviruses can be made to adsorb or to pass through membrane filters by manipulation of the suspending medium. Salts facilitate virus adsorption, but membrane-coating components (MCC) interfere. Because cells release MCC into the culture medium during viral growth, MCC must be removed before virus can be adsorbed to membranes. Adsorbed virus can be eluted with diluents containing MCC (cell extracts or serum) or agents that reduce surface tension (sodium lauryl sulfate). By membrane adsorption and elution, enteroviruses can be readily concentrated and quantitatively recovered from crude virus harvests.  相似文献   

4.
Summary Cellulose ester and polycarbonate membrane filters were tested for sterilizing capability with a contaminant,Corynebacterium aquaticum, isolated from cell culture medium. This contaminant, often found in water supplies, routinely passes filters of the polycarbonate type, but not of the cellulose ester type.C. aquaticum grows slowly requiring 7 to 10 days incubation in BME at 37°C before turbidity develops. Cryptic contamination is potentially a serious problem with this organism. This work was supported in part by USPHS Grant 5 F32 CA05635-02 from the National Cancer Institute.  相似文献   

5.
Why do viruses sometimes not pass through larger pores in track-etch filters? Increasing the salinity (0.8 to 160 mM Na+) decreased phiX174 and PRD1 passage through track-etch polycarbonate membranes (sodium dodecyl sulfate coated but not polyvinylpyrrolidone coated) and PRD1 passage through polyester membranes. Undiminished passage when 0.1% Tween 80 was added implied that nonionic virus adsorption occurred and indicated that high levels of salinity decreased virus passage by decreasing electrostatic repulsion that prevented adsorption.  相似文献   

6.
Poliovirus-seeded tap water, conditioned with MgCl2 and passed through virus-adsorbing filters, gave better poliovirus recovery than water identically treated but conditioned with AlCl3. Elution of several filter types with beef extract yielded higher recoveries than did elution with glycine. Seeded samples filtered through various filters and stored showed considerable virus loss in 2 days when stored at 4 degrees C, whereas those stored at -70 degrees C gave stable virus recovery up to 4 days. Additionally, the use of antifoam during the elution process reduced foaming and increased virus recovery by 28%.  相似文献   

7.
Processing and transport of environmental virus samples.   总被引:2,自引:1,他引:1       下载免费PDF全文
Poliovirus-seeded tap water, conditioned with MgCl2 and passed through virus-adsorbing filters, gave better poliovirus recovery than water identically treated but conditioned with AlCl3. Elution of several filter types with beef extract yielded higher recoveries than did elution with glycine. Seeded samples filtered through various filters and stored showed considerable virus loss in 2 days when stored at 4 degrees C, whereas those stored at -70 degrees C gave stable virus recovery up to 4 days. Additionally, the use of antifoam during the elution process reduced foaming and increased virus recovery by 28%.  相似文献   

8.
The presence of 'ultramicrocells' in natural mineral water, capable of passing through a 0.2 micron filter, has been demonstrated. Filters allowing the greatest proportion of viable (culturable) cells to pass ranked in the order, 0.4 micron polycarbonate (5.02%) > 0.2 micron polycarbonate (0.02%) > or = 0.45 micron cellulose nitrate (0.02%) > 0.2 micron cellulose acetate (< 0.002%). Following incubation for 4 d at 22 degrees C, viable counts in filtered mineral water increased from < 2-8.7 x 10(2) cfu ml-1(-2).8 x 10(4)-1.9 x 10(6) cfu ml-1. Successive filtration/incubation cycles of mineral water increased the proportion of cells passing through a 0.2 micron cellulose acetate filter from < 0.003% to 0.11% and 0.69%, suggesting selection for 'ultramicrocells'. Cells isolated from this process and grown on liquid R2A medium were thin, Gram-negative rods, of 0.15-0.40 micron wide and 0.50-6.20 microns long. Membrane filtration techniques used for pathogen detection in mineral waters will not retain all the cells present. If pathogens are able to form ultramicrocells, these may go undetected.  相似文献   

9.
We have reported previously (H. R. Kotilainen, J. P. Brinker, J. L. Avato, and N. M. Gantz, Arch. Intern. Med. 149:2749-2753, 1989) that the quality of nonsterile examination gloves available for clinical use may be extremely variable. In view of the concern over human immunodeficiency virus and hepatitis B virus transmission to health care workers, the continuing variability of gloves available for use, and the need for a simple and safe test, we have evaluated 2,500 vinyl (five brands) and 2,000 latex (four brands) gloves by the 300-ml and the newly proposed 1,000-ml water tests and for permeability to herpes simplex virus type 1 and poliovirus type 1, respectively. While all 300-ml watertight gloves were unlikely to leak herpes simplex virus type 1 (1.3% vinyl; 0.5% latex), poliovirus was recovered much more frequently (8.9% vinyl, 6.1% latex). In all gloves that passed the 1,000-ml test, herpes simplex virus type 1 was not recovered. Poliovirus was recovered infrequently (1.4% vinyl, 1.5% latex). Preliminary analyses suggest that the 1,000-ml water test has significantly increased sensitivity over the 300-ml water test in the detection of small holes in both vinyl and latex gloves that may allow the passage of viral particles. Gloves that pass a 1,000-ml water challenge are unlikely to allow the passage of a small virus such as poliovirus. Given that human immunodeficiency virus, hepatitis B virus and herpes simplex virus type 1 are larger particles than poliovirus, gloves that pass the 1,000-ml water test theoretically could provide better protection.  相似文献   

10.
We have reported previously (H. R. Kotilainen, J. P. Brinker, J. L. Avato, and N. M. Gantz, Arch. Intern. Med. 149:2749-2753, 1989) that the quality of nonsterile examination gloves available for clinical use may be extremely variable. In view of the concern over human immunodeficiency virus and hepatitis B virus transmission to health care workers, the continuing variability of gloves available for use, and the need for a simple and safe test, we have evaluated 2,500 vinyl (five brands) and 2,000 latex (four brands) gloves by the 300-ml and the newly proposed 1,000-ml water tests and for permeability to herpes simplex virus type 1 and poliovirus type 1, respectively. While all 300-ml watertight gloves were unlikely to leak herpes simplex virus type 1 (1.3% vinyl; 0.5% latex), poliovirus was recovered much more frequently (8.9% vinyl, 6.1% latex). In all gloves that passed the 1,000-ml test, herpes simplex virus type 1 was not recovered. Poliovirus was recovered infrequently (1.4% vinyl, 1.5% latex). Preliminary analyses suggest that the 1,000-ml water test has significantly increased sensitivity over the 300-ml water test in the detection of small holes in both vinyl and latex gloves that may allow the passage of viral particles. Gloves that pass a 1,000-ml water challenge are unlikely to allow the passage of a small virus such as poliovirus. Given that human immunodeficiency virus, hepatitis B virus and herpes simplex virus type 1 are larger particles than poliovirus, gloves that pass the 1,000-ml water test theoretically could provide better protection.  相似文献   

11.
Because naturally occurring organic matter is thought to interfere with virus adsorption to microporous filters, humic and fulvic acids isolated from a highly colored, soft surface water were used as model organics in studies on poliovirus adsorption to and recovery from electropositive Virosorb 1MDS and electronegative Filterite filters. Solutions of activated carbon-treated tap water containing 3, 10, and 30-mg/liter concentrations of humic or fulvic acid were seeded with known amounts of poliovirus and processed with Virosorb 1MDS filters at pH 7.5 or Filterite filters at pH 3.5 (with and without 5 mM MgCl2). Organic acids caused appreciable reductions in virus adsorption and recovery efficiencies with both types of filter. Fulvic acid caused greater reductions in poliovirus recovery with Virosorb 1MDS filters than with Filterite filters. Fulvic acid interference with poliovirus recovery by Filterite filters was overcome by the presence of 5 mM MgCl2. Although humic acid reduced poliovirus recoveries by both types of filter, its greatest effect was on virus elution and recovery from Filterite filters. Single-particle analyses demonstrated MgCl2 enhancement of poliovirus association with both organic acids at pH 3.5. The mechanisms by which each organic acid reduced virus adsorption and recovery appeared to be different for each type of filter.  相似文献   

12.
The effects of humic acid on poliovirus type 1 recovery from water by Zeta Plus 60S filters were investigated. The humic acid interfered by preventing virus adsorption to the filters, and the interference increased as a function of the amount of humic acid filtered. Humic acid decreased virus adsorption when filtered before the virus, but did not elute virus which had adsorbed to the filters. The effects on virus recovery were not due to alterations in virus titer or neutralizability. The addition of AlCl3, which improved virus recovery by electronegative filters in the presence of humic acid, did not aid in overall virus recovery by the Zeta Plus filters in the presence or absence of humic acid. However, the salt and humic acid in combination improved virus adsorption and concurrently reduced virus elution efficiency. The addition of NaH2PO4 had no direct effect on virus recovery and did not alter the effect of humic acid. In an attempt to identify the components of humic acid responsible for the interference, humic materials were fractionated by size by using Sephadex gel chromatography and dialysis, and the fractions were tested for interfering activity. Interference was not associated with specific size fractions of the humic materials.  相似文献   

13.
The effects of humic acid on poliovirus type 1 recovery from water by Zeta Plus 60S filters were investigated. The humic acid interfered by preventing virus adsorption to the filters, and the interference increased as a function of the amount of humic acid filtered. Humic acid decreased virus adsorption when filtered before the virus, but did not elute virus which had adsorbed to the filters. The effects on virus recovery were not due to alterations in virus titer or neutralizability. The addition of AlCl3, which improved virus recovery by electronegative filters in the presence of humic acid, did not aid in overall virus recovery by the Zeta Plus filters in the presence or absence of humic acid. However, the salt and humic acid in combination improved virus adsorption and concurrently reduced virus elution efficiency. The addition of NaH2PO4 had no direct effect on virus recovery and did not alter the effect of humic acid. In an attempt to identify the components of humic acid responsible for the interference, humic materials were fractionated by size by using Sephadex gel chromatography and dialysis, and the fractions were tested for interfering activity. Interference was not associated with specific size fractions of the humic materials.  相似文献   

14.
Poliovirus concentration from tap water with electropositive adsorbent filters   总被引:10,自引:0,他引:10  
Simple, reliable, and efficient concentration of poliovirus from tap water was obtained with two types of electropositive filter media, one of which is available in the form of a pleated cartridge filter (Virozorb 1MDS). Virus adsorption from tap water between pH 3.5 and 7.5 was more efficient with electropositive filters than with Filterite filters. Elution of adsorbed viruses was more efficient with beef extract in glycine, pH 9.5, than with glycine-NaOH, pH 11.0. In paired comparative studies, electropositive filters, with adsorption at pH 7.5 and no added polyvalent cation salts, gave less variable virus concentration efficiencies than did Filterite filters with adsorption at pH 3.5 plus added MgCl2. Recovery of poliovirus from 1,000-liter tap water volumes was approximately 30% efficient with both Virozorb 1MDS and Filterite pleated cartridge filters, but the former were much simpler to use. The virus adsorption behavior of these filters appears to be related to their surface charge properties, with more electropositive filters giving more efficient virus adsorption from tap water at higher pH levels.  相似文献   

15.
Because naturally occurring organic matter is thought to interfere with virus adsorption to microporous filters, humic and fulvic acids isolated from a highly colored, soft surface water were used as model organics in studies on poliovirus adsorption to and recovery from electropositive Virosorb 1MDS and electronegative Filterite filters. Solutions of activated carbon-treated tap water containing 3, 10, and 30-mg/liter concentrations of humic or fulvic acid were seeded with known amounts of poliovirus and processed with Virosorb 1MDS filters at pH 7.5 or Filterite filters at pH 3.5 (with and without 5 mM MgCl2). Organic acids caused appreciable reductions in virus adsorption and recovery efficiencies with both types of filter. Fulvic acid caused greater reductions in poliovirus recovery with Virosorb 1MDS filters than with Filterite filters. Fulvic acid interference with poliovirus recovery by Filterite filters was overcome by the presence of 5 mM MgCl2. Although humic acid reduced poliovirus recoveries by both types of filter, its greatest effect was on virus elution and recovery from Filterite filters. Single-particle analyses demonstrated MgCl2 enhancement of poliovirus association with both organic acids at pH 3.5. The mechanisms by which each organic acid reduced virus adsorption and recovery appeared to be different for each type of filter.  相似文献   

16.
Simple, reliable, and efficient concentration of poliovirus from tap water was obtained with two types of electropositive filter media, one of which is available in the form of a pleated cartridge filter (Virozorb 1MDS). Virus adsorption from tap water between pH 3.5 and 7.5 was more efficient with electropositive filters than with Filterite filters. Elution of adsorbed viruses was more efficient with beef extract in glycine, pH 9.5, than with glycine-NaOH, pH 11.0. In paired comparative studies, electropositive filters, with adsorption at pH 7.5 and no added polyvalent cation salts, gave less variable virus concentration efficiencies than did Filterite filters with adsorption at pH 3.5 plus added MgCl2. Recovery of poliovirus from 1,000-liter tap water volumes was approximately 30% efficient with both Virozorb 1MDS and Filterite pleated cartridge filters, but the former were much simpler to use. The virus adsorption behavior of these filters appears to be related to their surface charge properties, with more electropositive filters giving more efficient virus adsorption from tap water at higher pH levels.  相似文献   

17.
Tangential (crossflow) filtration of a plasma/serum mixture through 0.2 micrometer-poresize polycarbonate track-etch membrane filters (PC) at pressures less than 10 psi removes low density lipoproteins (LDL) and very low density lipoproteins (VLDL) but not high density lipoproteins (HDL) from the filtrate. At pressures greater than 10 psi all lipoproteins pass through the PC. Once the filters have been intruded with LDL and VLDL those lipoproteins continue to pass the filters despite subsequent reduction in differential pressure below 10 psi.  相似文献   

18.
Characterization of UVC light sensitivity of vaccinia virus   总被引:1,自引:0,他引:1  
Interest in airborne smallpox transmission has been renewed because of concerns regarding the potential use of smallpox virus as a biothreat agent. Air disinfection via upper-room 254-nm germicidal UV (UVC) light in public buildings may reduce the impact of primary agent releases, prevent secondary airborne transmission, and be effective prior to the time when public health authorities are aware of a smallpox outbreak. We characterized the susceptibility of vaccinia virus aerosols, as a surrogate for smallpox, to UVC light by using a benchtop, one-pass aerosol chamber. We evaluated virus susceptibility to UVC doses ranging from 0.1 to 3.2 J/m(2), three relative humidity (RH) levels (20%, 60%, and 80%), and suspensions of virus in either water or synthetic respiratory fluid. Dose-response plots show that vaccinia virus susceptibility increased with decreasing RH. These plots also show a significant nonlinear component and a poor fit when using a first-order decay model but show a reasonable fit when we assume that virus susceptibility follows a log-normal distribution. The overall effects of RH (P < 0.0001) and the suspending medium (P = 0.014) were statistically significant. When controlling for the suspending medium, the RH remained a significant factor (P < 0.0001) and the effect of the suspending medium was significant overall (P < 0.0001) after controlling for RH. Virus susceptibility did not appear to be a function of virus particle size. This work provides an essential scientific basis for the design of effective upper-room UVC installations for the prevention of airborne infection transmission of smallpox virus by characterizing the susceptibility of an important orthopoxvirus to UVC exposure.  相似文献   

19.
Acid rinsing, used to decontaminate filters in 14C productionstudies, caused cell rupture and resulted in elevated 14C countsin the filtrates of six out of seven phytoplankton samples.Large volume (50 ml) rinses using only water caused some, butlesser, damage. Comparing the recovery of 14C-labelled cellsand chlorophyll a on glass-fibre, polycarbonate and celluloseester filters revealed unaccountable losses at times with allthree filter types. These losses could not be explained by cellrupture, attachment to the filter funnel wall, filter treatmentor self-absorption during scintillation counting. Compared tothe whole sample acid bubbling method, recovery on the glass-fibrefilters was highest. Results for the polycarbonate filters weremore variable, while, in all cases, recovery on cellulose esterfilters was much lower.  相似文献   

20.
Delta-9-Tetrahydrocannabinol (THC) was found to reduce the infectivity of herpes simplex virus and was without effect against adenovirus type 2 or poliovirus. The effective THC concentration resulting in an 80% decrement in virus viability was dependent upon the presence or absence of serum in the incubation mixture, as a 5% serum concentration decreased the drug activity by approximately 50-fold. THC-mediated inactivation of herpes simplex virus was both time and dose dependent and did not result in virion disassembly or clumping. The THC-related effect was not influenced by the pH of the suspending medium, suggesting that the mechanism of inactivation differed from that associated with the thermal inactivation of the virus. Thus, the data suggest that THC preferentially reduces the infectivity of the enveloped herpes simplex virus, and that this activity is modulated by the presence of serum proteins.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号