首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
AIMS: To evaluate the decontamination of Bacillus anthracis, Bacillus subtilis, and Geobacillus stearothermophilus spores on indoor surface materials using hydrogen peroxide gas. METHODS AND RESULTS: Bacillus anthracis, B. subtilis, and G. stearothermophilus spores were dried on seven types of indoor surfaces and exposed to > or =1000 ppm hydrogen peroxide gas for 20 min. Hydrogen peroxide exposure significantly decreased viable B. anthracis, B. subtilis, and G. stearothermophilus spores on all test materials except G. stearothermophilus on industrial carpet. Significant differences were observed when comparing the reduction in viable spores of B. anthracis with both surrogates. The effectiveness of gaseous hydrogen peroxide on the growth of biological indicators and spore strips was evaluated in parallel as a qualitative assessment of decontamination. At 1 and 7 days postexposure, decontaminated biological indicators and spore strips exhibited no growth, while the nondecontaminated samples displayed growth. CONCLUSIONS: Significant differences in decontamination efficacy of hydrogen peroxide gas on porous and nonporous surfaces were observed when comparing the mean log reduction in B. anthracis spores with B. subtilis and G. stearothermophilus spores. SIGNIFICANCE AND IMPACT OF THE STUDY: These results provide comparative information for the decontamination of B. anthracis spores with surrogates on indoor surfaces using hydrogen peroxide gas.  相似文献   

2.
Aims: To obtain data on the efficacy of various liquid and foam decontamination technologies to inactivate Bacillus anthracis Ames and Bacillus subtilis spores on building and outdoor materials. Methods and Results: Spores were inoculated onto test coupons and positive control coupons of nine different materials. Six different sporicidal liquids were spray‐applied to the test coupons and remained in contact for exposure times ranging from 10 to 70 min. Following decontamination, spores were recovered from the coupons and efficacy was quantified in terms of log reduction. Conclusions: The hydrogen peroxide/peracetic acid products were the most effective, followed by decontaminants utilizing hypochlorous acid chemistry. Decontamination efficacy varied by material type. Significance and Impact of the Study: The study results may be useful in the selection of technologies to decontaminate buildings and outdoor areas in the event of contamination with B. anthracis spores. These results may also facilitate selection of decontaminant liquids for the inactivation of other spore‐forming infectious disease agents.  相似文献   

3.
The ability to reliably and reproducibly sample surfaces contaminated with a biological agent is a critical step in measuring the extent of contamination and determining if decontamination steps have been successful. The recovery operations following the 2001 attacks with Bacillus anthracis spores were complicated by the fact that no standard sample collection format or decontamination procedures were established. Recovery efficiencies traditionally have been calculated based upon biological agents which were applied to test surfaces in a liquid format and then allowed to dry prior to sampling tests, which may not be best suited for a real-world event with aerosolized biological agents. In order to ascertain if differences existed between air-dried liquid deposition and biological spores which were allowed to settle on a surface in a dried format, a study was undertaken to determine if differences existed in surface sampling recovery efficiencies for four representative surfaces. Studies were then undertaken to compare sampling efficiencies between liquid spore deposition and aerosolized spores which were allowed to gradually settle under gravity on four different test coupon types. Tests with both types of deposition compared efficiencies of four unique swabbing materials applied to four surfaces with various surface properties. Our studies demonstrate that recovery of liquid-deposited spores differs significantly from recovery of dry aerosol-deposited spores in most instances. Whether the recovery of liquid-deposited spores is overexaggerated or underrepresented with respect to that of aerosol-deposited spores depends upon the surface material being tested.  相似文献   

4.
AIMS: To evaluate the decontamination of Bacillus anthracis, Bacillus subtilis, and Geobacillus stearothermophilus spores on indoor surface materials using formaldehyde gas. METHODS AND RESULTS: B. anthracis, B. subtilis, and G. stearothermophilus spores were dried on seven types of indoor surfaces and exposed to approx. 1100 ppm formaldehyde gas for 10 h. Formaldehyde exposure significantly decreased viable B. anthracis, B. subtilis, and G. stearothermophilus spores on all test materials. Significant differences were observed when comparing the reduction in viable spores of B. anthracis with B. subtilis (galvanized metal and painted wallboard paper) and G. stearothermophilus (industrial carpet and painted wallboard paper). Formaldehyde gas inactivated>or=50% of the biological indicators and spore strips (approx. 1x10(6) CFU) when analyzed after 1 and 7 days. CONCLUSIONS: Formaldehyde gas significantly reduced the number of viable spores on both porous and nonporous materials in which the two surrogates exhibited similar log reductions to that of B. anthracis on most test materials. SIGNIFICANCE AND IMPACT OF THE STUDY: These results provide new comparative information for the decontamination of B. anthracis spores with surrogates on indoor surfaces using formaldehyde gas.  相似文献   

5.
AIMS: To compare the relative sensitivity of Bacillus anthracis and spores of other Bacillus spp. deposited on different solid surfaces to inactivation by liquid chemical disinfecting agents. METHODS AND RESULTS: We prepared under similar conditions spores from five different virulent and three attenuated strains of B. anthracis, as well as spores of Bacillus subtilis, Bacillus atrophaeus (previously known as Bacillus globigii), Bacillus cereus, Bacillus thuringiensis and Bacillus megaterium. As spore-surface interactions may bias inactivation experiments, we evaluated the relative binding of different spores to carrier materials. The survival of spores deposited on glass, metallic or polymeric surfaces were quantitatively measured by ASTM standard method E-2414-05 which recovers spores from surfaces by increasing stringency. The number of spores inactivated by each decontaminant was similar and generally within 1 log among the 12 different Bacillus strains tested. This similarity among Bacillus strains and species was observed through a range of sporicidal efficacy on spores deposited on painted metal, polymeric rubber or glass. CONCLUSIONS: The data obtained indicate that the sensitivity of common simulants (B. atrophaeus and B. subtilis), as well as spores of B. cereus, B. thuringiensis, and B. megaterium, to inactivation by products that contain either: peroxide, chlorine or oxidants is similar to that shown by spores from all eight B. anthracis strains studied. SIGNIFICANCE AND IMPACT OF THE STUDY: The comparative results of the present study suggest that decontamination and sterilization data obtained with simulants can be safely extrapolated to virulent spores of B. anthracis. Thus, valid conclusions on sporicidal efficacy could be drawn from safer and less costly experiments employing non-pathogenic spore simulants.  相似文献   

6.
The feasibility of utilizing vapor-phase hydrogen peroxide (VPHP) as a surface decontaminant and sterilant was evaluated in a centrifuge application. The prototype VPHP decontamination system, retrofitted into a Beckman L8-M ultracentrifuge, was designed to vaporize a 30% (wt/wt) solution of aqueous hydrogen peroxide continuously injecting and withdrawing VPHP in a deep-vacuum flow-through system. VPHP cycles of 4, 8, 16, and 32 min were examined for cidal activity against spores of Bacillus subtilis subsp. globigii and Bacillus stearothermophilus. Spore inocula (approximately 10(6)/coupon) were dried onto 0.5-in. (1.27-cm)-square stainless-steel coupons, and coupons were suspended in the centrifuge chamber, the space between the refrigeration can and the barrier ring (inner gap), and the space between the barrier ring and the vacuum ring (outer gap). At a chamber temperature of 4 degrees C, B. subtilis subsp. globigii spores were inactivated within 8 min, while inactivation of spores located in the outer gap at 27 degrees C required 32 min. The elevated temperature and high surface area/volume ratios in the outer gap may serve to decompose the gas more rapidly, thus reducing cidal efficacy. Of the two test spores, B. stearothermophilus was more resistant to VPHP. Nonetheless, VPHP was shown to possess significant sporicidal capability. For practical decontamination applications of the type described, VPHP shows promise as an effective and safer alternative to currently used ethylene oxide or formaldehyde vapors.  相似文献   

7.
Vapor-phase hydrogen peroxide as a surface decontaminant and sterilant   总被引:2,自引:0,他引:2  
The feasibility of utilizing vapor-phase hydrogen peroxide (VPHP) as a surface decontaminant and sterilant was evaluated in a centrifuge application. The prototype VPHP decontamination system, retrofitted into a Beckman L8-M ultracentrifuge, was designed to vaporize a 30% (wt/wt) solution of aqueous hydrogen peroxide continuously injecting and withdrawing VPHP in a deep-vacuum flow-through system. VPHP cycles of 4, 8, 16, and 32 min were examined for cidal activity against spores of Bacillus subtilis subsp. globigii and Bacillus stearothermophilus. Spore inocula (approximately 10(6)/coupon) were dried onto 0.5-in. (1.27-cm)-square stainless-steel coupons, and coupons were suspended in the centrifuge chamber, the space between the refrigeration can and the barrier ring (inner gap), and the space between the barrier ring and the vacuum ring (outer gap). At a chamber temperature of 4 degrees C, B. subtilis subsp. globigii spores were inactivated within 8 min, while inactivation of spores located in the outer gap at 27 degrees C required 32 min. The elevated temperature and high surface area/volume ratios in the outer gap may serve to decompose the gas more rapidly, thus reducing cidal efficacy. Of the two test spores, B. stearothermophilus was more resistant to VPHP. Nonetheless, VPHP was shown to possess significant sporicidal capability. For practical decontamination applications of the type described, VPHP shows promise as an effective and safer alternative to currently used ethylene oxide or formaldehyde vapors.  相似文献   

8.
Aims: To evaluate the inactivation of Bacillus anthracisΔSterne and Ames spores using electrochemically generated liquid‐phase chlorine dioxide (eClO2) and compare two sporulation and decontamination methods with regard to cost, safety and technical constraints. Methods and Results: Spores were prepared via agar and broth methods and subsequently inoculated and dried onto clean, autoclave‐sterilized glass coupons. Bacillus anthracis spore inactivation efficacy was evaluated using the modified three‐step method (AOAC 2008.05) and a single‐tube extraction method. Spores (7·0 ± 0·5 logs) were inactivated within 1 min at room temperature using freshly prepared eClO2. Bacillus anthracisΔSterne spores decreased in size after eClO2 treatment as measured using a Beckman Coulter Multisizer. Conclusions: eClO2 saturation of a hard surface was an effective B. anthracis sporicide. Broth sporulation and the single‐tube extraction method required less time and fewer steps, yielded a higher percentage of phase‐bright spores and showed higher spore recovery efficiency compared with AOAC 2008.05, making it more amenable to biosafety level 3 (BSL3) testing of virulent spores. Significance and Impact of the Study: Two test methods demonstrated the sporicidal efficacy of eClO2. A new single‐tube extraction test protocol for decontaminants was introduced.  相似文献   

9.
Decontamination studies investigating the effectiveness of products and processes for the inactivation of Bacillus species spores have traditionally utilized metering viable spores in a liquid suspension onto test materials (coupons). The current study addresses the representativeness of studies using this type of inoculation method compared to when coupons are dosed with a metered amount of aerosolized spores. The understanding of this comparability is important in order to assess the representativeness of such laboratory-based testing when deciding upon decontamination options for use against Bacillus anthracis spores. Temporal inactivation of B. anthracis surrogate (B. subtilis) spores on representative materials using fumigation with chlorine dioxide, spraying of a pH-adjusted bleach solution, or immersion in the solution was investigated as a function of inoculation method (liquid suspension or aerosol dosing). Results indicated that effectiveness, measured as log reduction, was statistically significantly lower when liquid inoculation was used for some material and decontaminant combinations. Differences were mostly noted for the materials observed to be more difficult to decontaminate (i.e., wood and carpet). Significant differences in measured effectiveness were also noted to be a function of the pH-adjusted bleach application method used in the testing (spray or immersion). Based upon this work and the cited literature, it is clear that inoculation method, decontaminant application method, and handling of non-detects (i.e., or detection limits) can have an impact on the sporicidal efficacy measurements.  相似文献   

10.
11.
Microbial contaminants on spacecraft can threaten the scientific integrity of space missions due to probable interference with life detection experiments. Therefore, space agencies measure the cultivable spore load ("bioburden") of a spacecraft. A recent study has reported an insufficient recovery of Bacillus atrophaeus spores from Vectran fabric, a typical spacecraft airbag material (A. Probst, R. Facius, R. Wirth, and C. Moissl-Eichinger, Appl. Environ. Microbiol. 76:5148-5158, 2010). Here, 10 different sampling methods were compared for B. atrophaeus spore recovery from this rough textile, revealing significantly different efficiencies (0.5 to 15.4%). The most efficient method, based on the wipe-rinse technique (foam-spatula protocol; 13.2% efficiency), was then compared to the current European Space Agency (ESA) standard wipe assay in sampling four different kinds of spacecraft-related surfaces. Results indicate that the novel protocol out-performed the standard method with an average efficiency of 41.1% compared to 13.9% for the standard method. Additional experiments were performed by sampling Vectran fabric seeded with seven different spore concentrations and five different Bacillus species (B. atrophaeus, B. anthracis Sterne, B. megaterium, B. thuringiensis, and B. safensis). Among these, B. atrophaeus spores were recovered with the highest (13.2%) efficiency and B. anthracis Sterne spores were recovered with the lowest (0.3%) efficiency. Different inoculation methods of seeding spores on test surfaces (spotting and aerosolization) resulted in different spore recovery efficiencies. The results of this study provide a step forward in understanding the spore distribution on and recovery from rough surfaces. The results presented will contribute relevant knowledge to the fields of astrobiology and B. anthracis research.  相似文献   

12.
As part of an effort to develop detectors for selected species of bacterial spores, we screened phage display peptide libraries for 7- and 12-mer peptides that bind tightly to spores of Bacillus subtilis. All of the peptides isolated contained the sequence Asn-His-Phe-Leu at the amino terminus and exhibited clear preferences for other amino acids, especially Pro, at positions 5 to 7. We demonstrated that the sequence Asn-His-Phe-Leu-Pro (but not Asn-His-Phe-Leu) was sufficient for tight spore binding. We observed equal 7-mer peptide binding to spores of B. subtilis and its most closely related species, Bacillus amyloliquefaciens, and slightly weaker binding to spores of the closely related species Bacillus globigii. These three species comprise one branch on the Bacillus phylogenetic tree. We did not detect peptide binding to spores of several Bacillus species located on adjacent and nearby branches of the phylogenetic tree nor to vegetative cells of B. subtilis. The sequence Asn-His-Phe-Leu-Pro was used to identify B. subtilis proteins that may employ this peptide for docking to the outer surface of the forespore during spore coat assembly and/or maturation. One such protein, SpsC, appears to be involved in the synthesis of polysaccharide on the spore coat. SpsC contains the Asn-His-Phe-Leu-Pro sequence at positions 6 to 10, and the first five residues of SpsC apparently must be removed to allow spore binding. Finally, we discuss the use of peptide ligands for bacterial detection and the use of short peptide sequences for targeting proteins during spore formation.  相似文献   

13.
Ultraviolet (u.v.) laser irradiation has been used to inactivate Bacillus subtilis spores deposited on to planar aluminium- and polyethylene-coated packaging surfaces. Kill kinetics were found to be diphasic, with an initial rapid inactivation phase followed by tailing. Although no definitive evidence was obtained, it is thought that spores located within packaging crevices/pores were primarily responsible for the observed tailing. Surviving spores were also found on the unexposed underside of cards and, to a lesser extent, within clumps. The log count reduction in B. subtilis was dependent on spore loading and total u.v. dose. In comparison, packaging surface composition, fluence (2-18 Jm-2) and frequency (40-150 Hz) had only a negligible effect. By irradiating boards carrying 106 spores, with a dose of 11.5 J cm-2, a log count reduction >5 was obtained. The mode of spore inactivation was primarily through DNA disruption. This was confirmed by the high sensitivity of spores lacking protective, small, acid-soluble proteins, in addition to the high frequency of auxotrophic and asporogenous mutations found amongst survivors.  相似文献   

14.
AIMS: To determine the mechanisms of Bacillus subtilis spore killing by and resistance to the general biological decontamination agents, Decon and Oxone. METHODS AND RESULTS: Spores of B. subtilis treated with Decon or Oxone did not accumulate DNA damage and were not mutagenized. Spore killing by these agents was increased if spores were decoated. Spores prepared at higher temperatures were more resistant to these agents, consistent with a major role for spore coats in this resistance. Neither Decon nor Oxone released the spore core's depot of dipicolinic acid (DPA), but Decon- and Oxone-treated spores more readily released DPA upon a subsequent normally sublethal heat treatment. Decon- and Oxone-killed spores initiated germination with dodecylamine more rapidly than untreated spores, but could not complete germination triggered by nutrients or Ca(2+)-DPA and did not degrade their peptidoglycan cortex. However, lysozyme treatment did not recover these spores. CONCLUSIONS: Decon and Oxone do not kill B. subtilis spores by DNA damage, and a major factor in spore resistance to these agents is the spore coat. Spore killing by both agents renders spores defective in germination, possibly because of damage to the inner membrane of spore. SIGNIFICANCE AND IMPACT OF STUDY: These results provide information on the mechanisms of the killing of bacterial spores by Decon and Oxone.  相似文献   

15.
Spores of Bacillus subtilis var. niger, dried on nonhygroscopic and hygroscopic surfaces, were enclosed in one of four thicknesses of low-density polyethylene film (2, 4, 6, and 20 mils). The surfaces were then placed in a specially designed thermochemical death rate apparatus and exposed to an ethylene oxide concentration of 600 mg/liter (at 54.4 C) and 50% relative humidity. Survival data, including both spore survivor curves and decimal reduction values (expressed as D values at 54.4 C-600 mg of ethylene oxide per liter), demonstrated similar survivor patterns when the B. subtilis var. niger spores were enclosed in low-density polyethylene films 2, 4, and 6 mils thick. A comparison of these patterns with those of spores enclosed in glassine and subjected to identical exposure conditions revealed only slight variations. The use of 20-mil polyethylene film greatly increased the time required to kill B. subtilis var. niger spores under the exposure conditions.  相似文献   

16.
AIMS: To investigate the cause and to eliminate the inactivation of Bacillus anthracis strain Sterne spores settled onto agar and stainless steel surfaces in plastic holders. METHODS AND RESULTS: In an experimental chamber in which spores settled onto sampling surfaces, vapourous hydrogen peroxide (VHP) was used for decontamination between experiments. It was demonstrated that hydrogen peroxide (H(2)O(2)) absorbed into plastic (Plexiglas) surfaces and could outgas in the sample holders. Further experiments demonstrated that H(2)O(2) was released from Plexiglas sample holders in sufficient quantity to inactivate spores. High temperature degassing (30-35 degrees C) for several days or aluminum coating of the surfaces were two remedies found to be effective in preventing inadvertent spore inactivation. CONCLUSIONS: H(2)O(2) can be absorbed into plastic and released after an extended period of time (weeks), allowing a sufficient concentration to accumulate in small volumes to inactivate spores. Outgassing the plastic or coating the surface with an impermeable layer are potential solutions to reduce spore inactivation. SIGNIFICANCE AND IMPACT OF THE STUDY: Many studies with bacilli and other organisms are carried out using small plastic containers that may have been sterilized using H(2)O(2) or other agents. This study presents a cautionary note to ensure elimination of H(2)O(2) or other sterilizing agents to prevent spurious results.  相似文献   

17.
P M Hauser  D Karamata 《Biochimie》1992,74(7-8):723-733
A reliable method for measuring the spore DNA content, based on radioactive DNA labelling, spore germination in absence of DNA replication and diphenylamine assay, was developed. The accuracy of the method, within 10-15%, is adequate for determining the number of chromosomes per spore, provided that the genome size is known. B subtilis spores were shown to be invariably monogenomic, while those of larger bacilli Bacillus megaterium, Bacillus cereus and Bacillus thuringiensis, often, if not invariably, contain two genomes. Attempts to modify the spore DNA content of B subtilis by altering the richness of the sporulation medium, the sporulation conditions (liquid or solid medium), or by mutation, were apparently unsuccessful. An increase of spore size with medium richness, not accompanied by an increase in DNA content, was observed. The implication of the apparently species-specific spore ploidy and the influence of the sporulation conditions on spore size and shape are discussed.  相似文献   

18.
Bacillus subtilis var. niger spores were placed on the surfaces of test coupons manufactured from typical spacecraft materials (stainless steel, magnesium, titanium, and aluminum). These coupons were then juxtaposed at the inoculated surfaces and subjected to test pressures of 0, 1,000, 5,000, and 10,000 psi. Tests were conducted in ambient, nitrogen, and helium atmospheres. While under the test pressure condition, the spores were exposed to 125 C for intervals of 5, 10, 20, 50, or 80 min, with survivor data being subjected to a linear regression analysis that calculated decimal reduction times. Differences in the dry-heat resistance of the test organism resulting from pressure, atmosphere, and material were observed.  相似文献   

19.
AIMS: To determine the mechanism whereby the new disinfectant Sterilox kills spores of Bacillus subtilis. METHODS AND RESULTS: Bacillus subtilis spores were readily killed by Sterilox and spore resistance to this agent was due in large part to the spore coats. Spore killing by Sterilox was not through DNA damage, released essentially no spore dipicolinic acid and Sterilox-killed spores underwent the early steps in spore germination, including dipicolinic acid release, cortex degradation and initiation of metabolism. However, these germinated spores never swelled and many had altered permeability properties. CONCLUSIONS: We suggest that Sterilox treatment kills dormant spores by oxidatively modifying the inner membrane of the spores such that this membrane becomes non-functional in the germinated spore leading to spore death. SIGNIFICANCE AND IMPACT OF THE STUDY: This work provides information on the mechanism of spore resistance to and spore killing by a new disinfectant.  相似文献   

20.
Bacteria of various Bacillus species are able to grow in media with very high osmotic strength in part due to the accumulation of low-molecular-weight osmolytes such as glycine betaine (GB). Cells of Bacillus species grown in rich and minimal media contained low levels of GB, but GB levels were 4- to 60-fold higher in cells grown in media with high salt. GB levels in Bacillus subtilis cells grown in minimal medium were increased approximately 7-fold by GB in the medium and 60-fold by GB plus high salt. GB was present in spores of Bacillus species prepared in media with or without high salt but at lower levels than in comparable growing cells. With spores prepared in media with high salt, GB levels were highest in B. subtilis spores and > or =20-fold lower in B. cereus and B. megaterium spores. Although GB levels in B. subtilis spores were elevated 15- to 30-fold by GB plus high salt in sporulation media, GB levels did not affect spore resistance. GB levels were similar in wild-type B. subtilis spores and spores that lacked major small, acid-soluble spore proteins but were much lower in spores that lacked dipicolinic acid.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号