首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A novel milliliter-scale bioreactor equipped with a gas-inducing impeller was developed with oxygen transfer coefficients as high as in laboratory and industrial stirred-tank bioreactors. The bioreactor reaches oxygen transfer coefficients of >0.4 s(-1). Oxygen transfer coefficients of >0.2 s(-1) can be maintained over a range of 8- to 12-mL reaction volume. A reaction block with integrated heat exchangers was developed for 48-mL-scale bioreactors. The block can be closed with a single gas cover spreading sterile process gas from a central inlet into the headspace of all bioreactors. The gas cover simultaneously acts as a sterile barrier, making the reaction block a stand-alone device that represents an alternative to 48 parallel-operated shake flasks on a much smaller footprint. Process control software was developed to control a liquid-handling system for automated sampling, titration of pH, substrate feeding, and a microtiter plate reader for automated atline pH and atline optical density analytics. The liquid-handling parameters for titration agent, feeding solution, and cell samples were optimized to increase data quality. A simple proportional pH-control algorithm and intermittent titration of pH enabled Escherichia coli growth to a dry cell weight of 20.5 g L(-1) in fed-batch cultivation with air aeration. Growth of E. coli at the milliliter scale (10 mL) was shown to be equivalent to laboratory scale (3 L) with regard to growth rate, mu, and biomass yield, Y(XS).  相似文献   

2.
A flow-through fluorescence polarization (FP) detection system that makes use of a novel high-performance liquid chromatography (HPLC) fluorescence detector modified with polarization filters was developed. This flow-through FP detection system was evaluated by using a novel and very cost-effective bioassay for cyclic adenosine monophosphate (cAMP). The bioassay was first evaluated and optimized in an FP plate reader format and subsequently in a flow-through bioassay setup. The principle of the bioassay is based on the competition of cAMP and a fluorescent cAMP derivative for the cAMP binding domain of protein kinase A. cAMP could accurately be determined over a range of 0.8 to 30 pmol/well in the plate reader FP assay and over a range of 0.3 to 50 pmol/well in the flow-through FP assay setup. High Z' factors (i.e., 0.89 for the plate reader and 0.93 for the flow-through FP cAMP assay, respectively) indicated robust assays. Finally, functional cAMP signaling of the human histamine H(3) G-protein-coupled receptor (GPCR) in cell cultures was measured with both assay formats with good sensitivities and assay windows. The pEC(50) values obtained in both assay formats were in accordance with those obtained with standard methods. The flow-through FP detection system could thus be used as a cost-effective alternative to FP plate reader assays. Moreover, the novel flow-through FP detection system for cAMP constitutes a good analytical tool to be used in the GPCR research field as an alternative to the use of FP plate readers or radioactive laboratories nowadays used for cAMP measurements.  相似文献   

3.
Microplate readers have been useful assistants of researchers for several decades. This work is focused on the applications of a simple absorbance microplate reader in yeast physiology research, and its advantages and limitations in comparison with alternative methods are discussed. The two main procedures involved are measuring growth curves and monitoring the pH changes of medium using two different pH indicators. We suggest mathematical formulas for converting absorbance data into pH values. With a microplate reader as many as 96 samples can be simultaneously analyzed, while medium consumption is minimized to 100 microL per sample. The results can be observed in 24-48 h (for growth curves) or in 1-3 h (for pH changes) with minimal hands-on time required.  相似文献   

4.
Ceramide kinase and its product ceramide 1-phosphate have been implicated in cellular proliferation and survival, activation of cytosolic phospholipase A(2), mast cell degranulation, and phagocytosis. Current assays for ceramide kinase activity employ [(32)P]ATP, with separation of labeled product from excess ATP by organic extraction and thin-layer chromatography. We have developed a fluorescent plate reader assay for ceramide kinase that uses commercially available C6-NBD ceramide (N-{6-[(7-nitro-2-1,3-benzoxadiazol-4-yl)amino]hexanoyl}-D-erythro-sphingosine). Our assay is based on the differential partitioning of substrate and product following a single chloroform/methanol extraction. The product, which partitions into the aqueous phase at physiological pH, is quantitated directly in a plate reader. The substrate may be delivered using either fatty acid-free albumin or detergent/lipid mixed micelles, and we have found that the use of albumin rather than detergent micelles allows one to detect lipid interactions with the enzyme that might otherwise go unnoticed. Our method is useful for assaying ceramide kinase activity both in vitro and in cultured cells, and it offers several advantages over the conventional assay, including greater speed, the ability to run a larger number of assay replicates at one time, and the elimination of environmental and safety issues associated with the use of radioactive materials.  相似文献   

5.
Z J Huang 《Biochemistry》1991,30(35):8530-8534
A novel enzymatic assay method was developed for fluorogenic substrates that have significant intrinsic absorbance and fluorescence under the assay conditions. Fluorescein mono-beta-D-galactoside (FMG) was chosen as the substrate for the fluorescence enzymatic assay because of the high fluorescence of its hydrolytic product (fluorescein) and suitability of being hydrolyzed by beta-galactosidase. The fluorescence-concentration relationships for fluorescein and for FMG in both the right-angle detection mode of a fluorometer and the front-face detection mode of a fluorescence plate reader were exactly established and used to determine the kinetics of the enzyme assay. The results show that only front-face detection in the fluorescence plate reader can overcome the fluorescence concentration quenching that inevitably results from high absorbance by the intrinsically absorbing substrate in the conventional fluorometer, which utilizes right-angle detection. Only with front-face detection was the fluorescent assay of FMG hydrolysis under conditions of high optical density possible. The enzymatic measurements on the fluorescence plate reader were particularly efficient for determination of the enzyme kinetics because of the high rate of data collection. In this assay system, Michaelis-Menten constant Km and enzymatic catalysis rate k2 of FMG were determined as 117.6 microM and 22.7 mumol-(min.mg)-1, respectively. The results and methods described in this paper can be generalized for any assay using a fluorogenic substrate whether or not it has a high background absorbance.  相似文献   

6.
A computerized system which greatly accelerates and eases the collection, storage, and analysis of data has been applied to several standard biochemical assays. The system uses a commercially available microtiter plate reader connected to an apple IIe microcomputer via a standard serial port. Data are transmitted automatically from the reader to the microcomputer, where they can be viewed, printed, further analyzed immediately, or stored on a diskette for later retrieval and processing. Some or all of the data may be entered manually. The program calculates a linear least squares best fit to a standard curve after correcting all data for blanks, then determines the quantities of substrate or product contained in each well of a microtiter plate. Data from two plates may be combined, enabling calculation of enzyme specific activities. This system can be adapted to any assay whose final step can be performed by a microtiter plate reader. Its use is described for determination of protein concentration, Na,K-ATPase activity, and K-stimulated p-nitrophenylphosphatase activity.  相似文献   

7.
8.
9.
Summary A number of methods have been developed to measure intracellular pH (pHi) because of its importance in intracellular events. A major advance in accurate pHi measurement was the development of the ratiometric fluorescent indicator dye, 2′,7′-bis(carboxyethyl)-5,6-carboxyfluorescein (BCECF). We have used a fluorescence multi-well plate reader and a ratiometric method for determining pHi in primary cultures of rabbit corneal epithelial (CE) cells with BCECF. Fluorescence was measured at excitation wavelengths of 485±11 nm and 395±12.5 nm, with emission detected at 530±15 nm. Cells grown in multi-well plates were loaded with 4 μM BCECF for 30 min at 37° C. Resting pHi was 7.34±0.03 (2 cultures, N=5 wells). Changes in pHi determined with the fluorescence multi-well plate reader after the addition and removal of NH4Cl or sodium lactate were comparable to changes in cells analyzed with a digitized fluorescence imaging system. A concentration-response relationship involving changes in pHi was easily demonstrated in CE cells after treatment with ionomycin, a calcium ionophore. Low doses of ionomycin (2.5–5 μM), produced a prolonged acidification; 7.5 μM ionomycin produced a transient acidification; and 10 μM ionomycin resulted in a slight alkalinization. We conclude that accurate pHi measurements can be obtained with a ratiometric method with BCECF in a multi-well plate reader. This technology may simplify screening studies evaluating effects of hormones, growth factors, or toxicants on pHi homeostasis.  相似文献   

10.
High-throughput (HT) miniature bioreactor (MBR) systems are becoming increasingly important to rapidly perform clonal selection, strain improvement screening, and culture media and process optimization. This study documents the initial assessment of a 24-well plate MBR system, Micro (micro)-24, for Saccharomyces cerevisiae, Escherichia coli, and Pichia pastoris cultivations. MBR batch cultivations for S. cerevisiae demonstrated comparable growth to a 20-L stirred tank bioreactor fermentation by off-line metabolite and biomass analyses. High inter-well reproducibility was observed for process parameters such as on-line temperature, pH and dissolved oxygen. E. coli and P. pastoris strains were also tested in this MBR system under conditions of rapidly increasing oxygen uptake rates (OUR) and at high cell densities, thus requiring the utilization of gas blending for dissolved oxygen and pH control. The E. coli batch fermentations challenged the dissolved oxygen and pH control loop as demonstrated by process excursions below the control set-point during the exponential growth phase on dextrose. For P. pastoris fermentations, the micro-24 was capable of controlling dissolved oxygen, pH, and temperature under batch and fed-batch conditions with subsequent substrate shot feeds and supported biomass levels of 278 g/L wet cell weight (wcw). The average oxygen mass transfer coefficient per non-sparged well were measured at 32.6 +/- 2.4, 46.5 +/- 4.6, 51.6 +/- 3.7, and 56.1 +/- 1.6 h(-1) at the operating conditions of 500, 600, 700, and 800 rpm shaking speed, respectively. The mixing times measured for the agitation settings 500 and 800 rpm were below 5 and 1 s, respectively.  相似文献   

11.
The demand to increase throughput in HTS programs, without a concomitant addition to costs, has grown significantly during the past few years. One approach to handle this demand is assay miniaturization, which can provide greater throughput, as well as significant cost savings through reduced reagent costs. Currently, one of the major challenges facing assay miniaturization is the ability to detect the assay signal accurately and rapidly in miniaturized formats. Digital imaging is a detection method that can measure fluorescent or luminescent signals in these miniaturized formats. In this study, an imaging system capable of detecting the signal from a fluorescent protease assay in multiple plate formats was used to evaluate this detection method in an HTS environment. A direct comparison was made between the results obtained from the imaging system and a fluorescent plate reader by screening 8,800 compounds in a 96-well plate format. The imaging system generated similar changes in relative signal for each well in the screen, identified the same active compounds, and yielded similar IC(50) values as compared to the plate reader. When a standard protease inhibitor was evaluated in 96-, 384-, 864-, and 1536-well plates using imaging detection, similar IC(50) values were obtained. Furthermore, similar dose-response curves were generated for the compound in 96- and 384-well assay plates read in a plate reader. These results provide support for digital imaging as an accurate and rapid detection method for high-density microtiter plates.  相似文献   

12.
A High-throughput End-point Assay for Viable Mammalian Cell Estimation   总被引:2,自引:0,他引:2  
A single wavelength colorimetric microplate-based assay was developed using non-cytotoxic dye resazurin for the estimation of viable cell concentrations of Chinese hamster ovary (CHO) and hybridoma cells. Experimental results showed variations in pH and temperature caused by cell cultivation and assay operations were well tolerated. Cell concentrations can be effectively determined in the range of 105–107 cells ml−1 using a microplate reader at the wavelength of 605 nm. This assay can be performed in a high-throughput manner such that a large number of cell culture samples can be screened within a relatively short time frame. When used together with a cell culture system of high-throughput format, it may have potential utilities in applications such as cell culture medium formulation and optimization.  相似文献   

13.
14.
The biopharmaceutical industry is increasing its use of the WAVE Bioreactor for culturing cells. Although this disposable bioreactor can be equipped to provide real-time pH and dissolved oxygen (DO) monitoring and control, our goal was to develop a process for culturing CHO cells in this system without relying on pH and DO feedback controls. After identifying challenges in culturing cells without controlling for pH and DO in the WAVE Bioreactor, we characterized O(2) and CO(2) transfer in the system. From these cell-free studies, we identified rock rate and rock angle as key parameters affecting O(2) transfer. We also identified the concentration of CO(2) in the incoming gas and the rate of gas flow into the headspace as key parameters affecting CO(2) transfer--and therefore pH--in the disposable culture chamber. Using a full-factorial design to evaluate the rock rate, rock angle, and gas flow rate defined for this WAVE Bioreactor process, we found comparable cell growth and pH profiles in the ranges tested for these three parameters in two CHO cell lines. This process supported cell growth, and maintained pH and DO within our desired range--pH 6.8-7.2 and DO exceeding 20% of air saturation--for six CHO cell lines, and it also demonstrated comparable cell growth and viability with the stirred-tank bioreactor process with online pH and DO control. By eliminating the use of pH and DO probes, this process provides a simple and more cost-effective method for culturing cells in the WAVE Bioreactor.  相似文献   

15.
Cancer cell spheroids present a relevant in vitro model of avascular tumors for anti-cancer drug testing applications. A detailed protocol for producing both mono-culture and co-culture spheroids in a high throughput 96-well plate format is described in this work. This approach utilizes an aqueous two-phase system to confine cells into a drop of the denser aqueous phase immersed within the second aqueous phase. The drop rests on the well surface and keeps cells in close proximity to form a single spheroid. This technology has been adapted to a robotic liquid handler to produce size-controlled spheroids and expedite the process of spheroid production for compound screening applications. Spheroids treated with a clinically-used drug show reduced cell viability with increase in the drug dose. The use of a standard micro-well plate for spheroid generation makes it straightforward to analyze viability of cancer cells of drug-treated spheroids with a micro-plate reader. This technology is straightforward to implement both robotically and with other liquid handling tools such as manual pipettes.  相似文献   

16.
We describe an in situ fluorescence optical detection system to demonstrate real‐time and non‐invasive detection of reaction products in a microfluidic device while under perfusion within a standard incubator. The detection system is designed to be compact and robust for operation inside a mammalian cell culture incubator for quantitative detection of fluorescent signal from microfluidic devices. When compared to a standard plate reader, both systems showed similar biphasic response curves with two linear regions. Such a detection system allows real‐time measurements in microfluidic devices with cells without perturbing the culture environment. In a proof‐of‐concept experiment, the cytochrome P450 1A1/1A2 activity of a hepatoma cell line (HepG2/C3A) was monitored by measuring the enzymatic conversion of ethoxyresorufin to resorufin. The hepatoma cell line was embedded in MatrigelTM construct and cultured in a microfluidic device with medium perfusion. The response of the cells, in terms of P450 1A1/1A2 activity, was significantly different in a plate well system and the microfluidic device. Uninduced cells showed almost no activity in the plate assay, while uninduced cells in MatrigelTM with perfusion in a microfluidic device showed high activity. Cells in the plate assay showed a significant response to induction with 3‐Methylcholanthrene while cells in the microfluidic device did not respond to the inducer. These results demonstrate that the system is a potentially useful method to measure cell response in a microfluidic system. Biotechnol. Bioeng. 2009; 104: 516–525 © 2009 Wiley Periodicals, Inc.  相似文献   

17.
18.
微生物在环境中的耐性是该微生物在相应环境发挥作用的重要基础。为了获得一种用于微生物耐性分析的快速简便方法,传统平板分离法和酶标仪分光光度法被用于评估其在细菌和链霉菌紫外耐受水平检测中的差异,并分析了酶标仪分光光度法在微生物其他耐性水平检测中的适用性。结果显示,两种检测方法均能体现细菌和链霉菌对紫外线的耐受水平,前者经过稀释、涂布、培养、菌落计数,获得的是菌株在紫外线照射后的存活浓度,而后者经过接种96孔培养板、培养、吸光度检测,获得的是菌株经紫外线照射后的生长曲线,并从生长曲线获知菌株的生长速率、增殖能力等信息。此外,酶标仪分光光度法同样适用于细菌对pH和盐的耐受水平分析,对于链霉菌耐受性分析有一定的适用性。酶标仪法除了能获得与平板分离法相似的耐性水平检测外,还能获得菌株在不同耐性水平上的增殖潜力,且在操作上比平板分离法省时、省力,可用于微生物耐性分析、高通量筛选等研究工作。  相似文献   

19.
The cholecystokinin receptor-type 1 (CCK1R) is a G-protein coupled receptor localized in the animal gastrointestinal tract. Receptor activation by the natural peptide ligand CCK leads to a feeling of satiety. In this study, hydrolysates from soy and milk proteins were evaluated for their potential to activate the CCK1R, assuming that bioactive peptides with a satiogenic effect can be used as an effective therapeutic strategy for obesity. Different protein hydrolysates were screened with a cell-based bioassay, which relies on the generation of a fluorescent signal upon receptor activation. Fluorescence was monitored using a fluorescence plate reader and confocal microscopy. Results from the fluorescence plate reader were biased by background autofluorescence of the protein hydrolysate matrices, which makes the fluorescence plate reader inappropriate for the evaluation of complex formulations. Measurements with the confocal microscope resulted in reliable and specific results. The latter approach showed that the gastrointestinal digested 7S fraction of soy protein demonstrates CCK1R activity.  相似文献   

20.
The introduction of automated pipetting devices, microtiter readers, and microcomputers makes it possible to significantly increase the number of enzyme assays which can be performed as part of the analysis of a biological process. A number of difficulties must be overcome in any such integrated approach based on the microtiter plate. Among these are cell lysis, temperature control, the conversion of microtiter reader optical density values to standard 1-cm path length values, and data management. The utility of such a scheme can be extended to gene regulation and bacterial genetics studies, if bacterial cell culture techniques can be incorporated into the scheme. This paper addresses these issues in the application of a semiautomated system to the study of the induction of the gyrA promoter by treatment (of a gyrA-lac operon fusion-containing strain) with a gyrase inhibitor. This system is specific to the requirements of our studies into the modulation of gene expression by DNA relaxation. The general approach, however, can be readily adapted to other studies.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号